Loading...
Report ..11) STREET TREE TIGARD CER TIFICA TION J;// -4/ owner/agent for Z -74-677)-/ (PLEASE PRINT) (PERMIT HOLDER) do hereby cert that the following location meets City of Tigard land use and development standards for street tree installation and is consistent with the approved site plan. PERMIT NO.: Mme) 206 SITE ADDRESS: / 1/ S)4/ /2 2 (,r SUBDIVISION. ,// 19 ,,,/ 4% `/17 - LOT #: SIGNATURE: � �: - � • DATE: l 3 2 s •WNER/AGENT) RECEIVED & VERIFIED BY: ' • DATE: 47/4 (C OF TIGARD) - ❑ Tree location verified per approved site plan. I:\Building\Forms\StreetTreeCertificate 05/30/2012 . Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM I, /9d -non://1 , am the general contractor or the owner-builder at the following address: Site Address: /r/W 5j4/ // ' C,7: City: �.7 ,/f Permit#: OH- /6'-- (28y " Subdivision/Lot#: .1�f/d fa"/ / ', , d Zoi) is K and/or • Map and Tax Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes, the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: -e - ----- Date: v , General Contractor or I er-Builder 41111 I:1Building\Form\RES-MoistureSensitiveWood.doc 09/25/08 Oregon Residential Specialty Code N1107.2 • HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: A/5)2.. / f ff on( Jurisdiction: 7:?-01/49�9 tr Site Address: / 26�/ Subdivision/Lot#: sg),/eiit?1 ✓�v9 9 ffA 4'J and/or Map and Tax Lot#: By my signature below, I certify that a minimum of fifty(50)percent of the permanently • installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 Signature: ` f Date: 2.19/ Owne General C•""actor/Authorized Agent Print Name: a),16! ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that • has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement. The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per input watt. I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08 r ,.JM Climate ProsFiber Glass Blowing Wool. f 7{!{:f_ l,: Your home has been professionally insulated to provide superior thermal resistance. 1 Homeowner's Name< _1 t F-Ut V\ 0,eNsiyuVY t Date /012��rq-- <,,`> i , Address I4-0is&X SW li g ' r, City U(' ir\"( State CR— Zip q�2 & j I. RECORD OF INSTALLATION (. BLOWING WOOL BATTS AND ROLLS r 0-New Construction If Retrofit: R-value Thickness Area Insulated J Retrofit Depth of Previous insulation in Ceilings in se ft f r'i{ Number of bags used L 0 Estimated H-value of Previous Installation insq ft Area Insulated LIDsq.ft Types of Previous Insulation in Attic Wats in. sq.II. "l '- Thickness of Insulation 142.in. in. sq.ft, R-value of Insulation Floors at. sq.ft at. sq.ft. l' ''I CLIMATE PRG INSULATION,BAG WEIGHT 28.5 LB.MINIMUM R-VALUE MINIMUM INSTALLED MAXIMUM NET MINIMUM WEIGHT SETTLED THICKNESS lin) BAGS PER 1,000 SO_F . + Ibr•sq.N-•`F/BTU) THICKNESS lin) COVERAGE Isq.ft./hat0 (lbs-/sq.n.) 1:.:' Installed insulation Expected thickness Minimum number of Contents of this bag The weight per sq.ft. To obtain an insulation should not he less after tong-term settling gags per 1,000 spit. should not cover of installed insulation �' resistance IHI of than has occured of net area: more than: should not be less than. 1},, 11 4.4 14 4.9 202 0.156 i 13 _ 5.2 _ 5.7 5.9 170 0 185 '*-' 19 7 4 7.4 8.7 114 0.275 l•,'- K;' 72 8.5 8.5 10.2 98 f 0.321 i 76 100 10.0 12.2 82 0.384 r .— 30 11,4 11.4 14.2 70 0.448 38 14.2 14.2 � 18.4 54 0.579 44 16.2 16.2 21.6 46__�_. 0.680 49 178 17.8 24.3 41 0.767 SfS ` 60 21.4 214 306 33 0963 (;: See reverse to eetermirre adfustnlent in coverage for Climate Pro Insulation installed in Minnesota nsuiation Contractor Signature _ Date _ IBP-PORTLAND 2738 N HAYDEN ISLAND DR 503-641-8188 1 t::' Company Address Phone _ Home Builder Signature Dale { CompanyAddress Phare I s' illiZI .,... I It . Johns Manville a •t r.•..- ;%,ic ,,,, " ..., d°',"�".,...\ 'i,^,T.<,..."k^> '�'.` , fr'F'�'�' '' 0. '',',-... `''i(X i ((}t .. .i'is Mane n 1'.t'1th Strom.Wow.CA 10202,specJM corm Fn more intnnnat n,call OW)u54.310. BIC-162 03(12 G 2012 Johns Manville.Printed in USA. c. ass - CCB#178624 Cel1P 0 Box 433 . R _ r vwr;,c,a, .,k,,, Clackamas, OR 97015 Phone: (503) 656-1908 Fax: (503) 650-3898 Technician Awn r �_,�_ Date: 2 10 t Builder Name: +J _Ci- Site Address: S e 5 _ _ _ - - -� - Duct Leakage Cond. Floor Area (sq.ft) eZL75 7 yesno Air Handler in conditioned space? yes, ,noAir Handler present during test? If"yes"for either, then floor area x 0.06= CFM@50 Pa Target CFM is the above or 75 CFM@50 pa,whichever is greater if"no"for either, then floor area x 0.06= CFM@50 Pa Target CFM is the above or 50 CFM@50 pa,whichever is greater Circle Test Metho' `- Leakage to Outside_ .r Total Leakage Test Result 1' CFM@50Pa Fan Pressure Pa Ring (circle one) Open 1 3 LurE! tb0n ct Blaster Location 7�9/ rdr t i�/ oca ' RI