Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (119)
-;&91_9° Z93 5& HINZE RESIDENCE Jai;, < v().) PHOTOVOLTAIC ARRAY 1,32, i4iioo 6.2 kW, 20 @ 310W SILFAB/ENPHASE CUSTOMER DONALD HINZE 12343 SOUTHWEST 132ND COURT M N o 0 TIGARD, OR 97223 ft 503-590-4056 donaldhinze37@gmail.com z 0 d3 W 0) cc 0 I— OW W i= V z F- ao CONTRACTOR AURIC SOLART 2310 SOUTH 1300 WEST m M WEST VALLEY, UT 84119cV CI fa 801-878-3363 permits@a uricsolar.corn DATE 12018 JOB NO: 175842 REVISION NO: 001 DESIGN BY: CH 1 °F 6 INDEX NOTES: ill 1.1=1111111 Q Sheet Number Sheet Title 1 1. ATTACHMENT FEET WILL BE FIELD ADJUSTED TO ACCOMMODATE TRUSS POSITIONS. _a TITLE 2. 5 FT MAXIMUM SPACING BETWEEN ATTACHMENT POINTS. 2 INDEX,LEGEND,MECHANICAL DETAILS&NOTES 3. RAIL END OVERHANG LIMITED TO LESS THAN 34% OF MAXIMUM SPAN (18 IN MAXIMUM). .41 0 3 4. SEE ATTACHED SHEETS FOR SNAP N RACK SERIES 100 WITH STAGGERED FLASHED41(1C (I) PLAN LAYOUT L-FOOT BASE DETAILS. 4 STRING LAYOUT&ELECTRICAL INTEGRATION 5. IF ARRAY IS CLOSER THAN 3' FROM ANY RIDGE, HIP OR EDGE, ATTACHMENT POINTS _ 5 SINGLE LINE IMUST BE 24" O.C. MAX. AS PER OSCC 311.5.3(3.2). /mss-- NTERCONNECTION DIAGRAM&LABELING 6. PV MODULES MUST NOT BE INSTALLED OVER OR BLOCK ANY ATTIC VENTS, PLUMBING /fec t 6 VENTS, FURNACE OR WATER VENTS, ETC. BILL OF MATERIALS 7. ARRAY WIRE MANAGEMENT SHALL BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 7-12 MEANS DESIGNED AND LISTED FOR SUCH USE AND HELD OFF THE ROOF SURFACE. \\\. � � SNAP N RACK SERIES 100 RACKING CUT SHEET 8. EGC's SHALL BE RUN WITH ASSOCIATED CIRCUIT CONDUCTORS IN ACCORDANCE WITH NEC 690.43(F) 13 SNAP N RACK UL LISTED HARDWARE 9. INSTALLER TO VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH 14 COMBINER/ENCLOSURE CUT SHEET NEC 250.50. 10.ALL INSTALLATIONS SHALL COMPLY WITH OSEIA REGULATIONS, 2015 BUILDING CODES & 15-18 ENPHASE MICROINVERTER&CABLING CUT SHEET 2014 NEC. 11.RAIL MIDCLAMPS CAN ONLY BE POSITIONED ±2" OF MOUNTING HOLE. MODULES IN LANDSCAPE ARE ONLY ALLOWED MIDCLAMPS FROM 4Y4" TO 93" FROM SHORT END OF 19-20 SILFAB SOLAR PANEL CUT SHEET MODULE. 21 CONTRACTOR'S LICENSE 12.STAINLESS STEEL ATTACHMENTS REQUIRED TO MITIGATE CORROSION. c» `o CV (j)N o 7 D-- w �� LEGEND DETAIL A DDETTAILB ~CC o �o Rail L-f WI 0 Z Na "L" FOOT FLASHING p t 2 - TRANSFORMER MO UTILITY METER (SEE NOTE 4) Q J FLASHED L-FUUI MOUNT w I % p\ (SEE NOTE 4) z F= tri c a J CIRCUIT BREAKER MO a- p PRODUCTION METER o � < ao�4 w �O Z am L n ��o ` c, Z 2 00 ® - UTILITY DISCONNECT I N i GROUND SYMBOL — w v N N CO w jL FOR ROOF = F— , Q`o '// / ANGLE SEE alliii.%;:i` w Z o m FIRE ACCESS SNAP N RACK t'-6"MAX. SHT. 3 w m`o SERIES 100 (SEE NOTE 3) S c, aN,T RAIL O X05 0 w vo DETAIL C DETAIL D PORTRAIT DRIENTAIICN SNAP N RACK ,, A DETAIL E M z gv. 3'-3` Y° REPRESENTS ATYPICAL FLASHED °L" FOOT B0N0 DER' Li cL a b I- 5' 5" Y" Y2" 3'-3` B (SEE DETAIL A) 1'_6^ MAX FOOT PLACEMENT SNAP N RACK I I I� TO FIRST FOOT I (SEE NOTE 5) SERIES 100 IMI I UT1I! ��� �NW �i� � RACKING SYSTEM REPRESENTS ATYPICAL (SEE NOTE 4) IMI__ II `� '' 1,1111111111111 FOOT PLACEMENT 0 � 1A nSNAP N RACK " (SEE NOTE 5) Bimmniim� SERIES 100 C 1 .� "'�w�� RACKING SYSTEM IMO SNAP N RACK ' w SEE NOTE 4 �_ JAI i•A Ir SERIES 100 =A _R SOLADECK _ PIRACKING SYSTEM �_SNAP N RACKEQUIPMENT1'-6° MAX (SEE NOTE 4) DATE: Y5/2018 TO FIRST FOOT FLASHED "L" FOOT GROUNDING �■■ JOB NO: 175842 SJ_�n (SEE DETAIL A) CONDUCTOR. 6 4'-0"TYP. STAGGER ATTACHMENT AWG BARE REVISION NO: 001 DESIGN BY: CH SEE NOTES SEE COPPER WIRE ��__ STAGGER ATTACHMENT POINTS BETWEEN ROWS SEE NOTES &2 1 &2 SNAP N RACK GROUND LUG POINTS BETWEEN ROWS (1 PER ROW REQUIRED) 2 - 6 NOTES: 1. FIELD ADJUST ARRAYS ON SLOPE FOR BEST \ �,. l'\\ U C PLACEMENT. \ f�� s 2. ALLOW 1' FROM RIDGE AS PER OREGON I \ / r1�� FIRE CODE. 1 % \\,, �p, 0 ' 3. STAGGERED ATTACHMENTS REQUIRED. SEE \ PAGE 2 DETAILS C & D. I \\\\ , 4. ROOF SO FT: 2,350 ARRAY SQ. FT: 356.6, y 15.2% COVERAGE. \ 5. RAFTER SPACING IS 24" O.C. (TYPICAL). 1 \ N. /104 / • • I fi• (4 I • •\ I N I \\ I NI 4' \ \ C ATTIC ACCESS \ M o N of N 1 N 0 a 0 Q N O I ci L O O Allk \ Q .a, I ca,„ ,„ NARRAY I - 0 U ~ v I 10 MODULES \\ w C <- 0 O O Qc 00 O 0Q ° w U - rn o� I NO ATTIC ACCESS 00 W z u a 00 ° ° I II L-------.. 44 o --. .._. 044 4 4 �° J a4 PV AC COMBINER BOX " ° �� MAIN SERVICE 4 v' 4 ROOF DESCRIPTION - - ° ARRAY ROOF TILT ROOF AZIMUTH TSRF ENTRANCE/ UTILITY METER ° 11 30' 198' 90% INDOOR LOAD CENTER #2 18' 198' 79; & PV UTILITY DISCONNECT _ e POINT OF INTERCONNECTION ASPHALT SHINGLE ROOF ARRAY 2--*"- \ 44'SILFAB SLA-M 310W MODULES 10 MODULES \ \ DATE: L 2018 ENPHASE IQ6PLUS-72-5-US MICROINVERTERS JOB Na 175842REVISION Na 001 20 © 310W = 6.2KW ' DESIGN BY: CH SCALE NO SCALE 3 - 6 SEE ATTACHED SHEET FOR DETAILS ( ) Cr L ARRAY 1-10 MODULES D 0 dr) CIRCUIT 1 .— SEE SHEET 5 t y � \1 00 0 0 ......„.............:1......), 1(k 00 f, \`.`�-°- 5D C1 C1` Cl C1%. C1 'F2- o � � 0 C1 C1 C1 ' C1tz C1 ' r co c tV (V �7 N- Z al LI 27'-3° 0) O O oc < N'a Q o Q ,- m§ ARRAY 2-10 MODULES CIRCUIT 2 w 1- SEE SHEEP 5 U a a A w — o O � <c (iii U (-) grn 00 00 0 NJ 1:9 Z O LEGEND N cu Y ENPHASE IQ6+ T I— j a o • 110- o A �' MICROINVERTERS w O c 2 1 C2�' C2 C2 ' C2 C2 r� B o SOLADECK a 0 C ® CABLE CONNECTOR O z Y° 0 N lg. C2a. T C2 C2 C2 C2' � D Q BRANCH TERMINATIONS N N o..,,-;u } E JUNCTION BOX R NOTES: 1. MODULES ARE BONDED TO RAILS USING SNAP N RACK BONDING MID CLAMPS. SEE CUT SHEETS FOR DETAILS. 27'-3' 2. ARRAY IS TO BE BONDED TO THE CIRCUIT EGC AT A SINGLE POINT PER ARRAY ROW SECTION WITH A LISTED BONDING LUG USING BARE 6 AWG COPPER. DATE: 15/2018 AS PER NEC 690.43. JOB NO: 175842 3. SEE CUT SHEETS FOR ENPHASE INVERTER CABLING REVISION NO: 001 ACCESSORIES SPECIFICATIONS AND DETAILS. DESIGN BY: CH 4. SEE CUT SHEETS FOR COMBINER/ENCLOSURE KALE Np sou SPECIFICATIONS. 4 OF NOTES: r G 1. METER SOCKET ONLY. (EXISTING) V 2. 200A RATED INDOOR LOAD CENTER, LOCATED IN GARAGE, CUTLER-HAMMER. d (EXISTING) lia 3. BOA RATED ENPHASE 10 AC COMBINER BOX. (NEW) 4. SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE,AC/DC-5D-786-3R. 5. SNAP N RACK JUNCTION BOX R, 242-01104. 6. SILFAB SLA-M 310W MODULES, ENPHASE IQ6PLUS-72-5-US ' MICRO-INVERTERS, ENPHASE Q CABLE. LOAD SIDE INTERCONNECTION 00000 ©Oi O 7D5.12(B)(2)(3)(b) -... /17,1"'''.'''':"S%) (t•..L.J0/1 EXISTING 200A/2P CO UTILITY —O 6-: SERVICE EXISTING WIRE OCPD O 2P — / I •INEW SOLAR J REFER TO GENERAL NOTES LABELING: EXISTING LOADS 2 10AWG N Z °^ fV J w u O (1)1OAWG NEUTRAL I` W 0 u CA m oal TO BE INSTALLED ON RAMO SHUTDOWN DEVICE (1)10AWG EGC -p p NEC 690.56(C) 3/4"CONDUIT MIN. O N o. PHOTOVOLTAIC 0 RAPID SHUTDOWN OA F CC M L u DEVICE 00 LD < c TO BE INSTALLED AT THE w I--- 0 7 y UTILITY/METER (, Q aN NEC 705.10 Z Q W PARALLEL ON-SITE W O0 ZQ SOLAR GENERATION OB (n F- - rn GENERAL NOTES: cc 0 w o v TO BE INSTALLED AT THE UD UTILITY/METER 20A/2P 20A/2P IV co Z �y NEC 690.56(C) o)NEW SOLAR of SOLAR 1. IF REQUIRED, AS PER NEC 705.12(B)(2)(3)(b), _Z O PHOTOVOLTAIC SYSTEM O LOAD SIDE INTERCONNECTED BREAKERS TO BE _ ~ U a o EQUIPPED INSTALLED AT OPPOSITE END OF BUSBAR FROM W w c m WITH RAPID SHUTDOWN 12/2 OF-B 12/2 UF-B INPUT FEEDER. I— goo- WITH `o (3/4"CONDUIT (3/4"CONDUIT 2. ALL CONDUCTORS SHALL BE 90' C THWN-2 = o T TO REINSTALLED ON PV DISCONNECT WHERENEEDED) WHERENEEDED) COPPER UNLESS OTHERWISE NOTED. D Z >9- TO 3. IN OREGON, ANY SYSTEM OVER 7.2kW DC O — m 0 MANUAL DISCONNECT FOR INVERTER OUTPUT REQUIRES A DISCONNECT w v o DO THAT IS MANUAL, LOCKABLE, LOAD BREAK, HAVE co (J'3 0 23.4 PARALLELA GENERATION VAC f O -uf—O A VISIBLE BREAK, AND BE LOCATED WITHIN 10 Cil JB-R FEET OF THE UTILITY METER. IF LOCATED a w TO BE INSTALLED NDE INTTO ERCONACS NECTIONED S BREAKERS O ELSEWHERE,AN APPROVED DIRECTORY DENOTING FOR 7 LOAD SIDE IMERCONNECIKKJS NECIBEIX5X2OW) ENPHASE ENPHASE IT'S LOCATION MUST BE INSTALLED AT THE WARNING- Q CABLE Q CABLE UTILITY METER. SEE SHEET 4 SEE SHEET 4 4. THE SIGN MUST BE REFLECTIVE, WITH ALL W INRTEROUTPUT CONNECTION E LETTERS CAPITALIZED, AND LETTERS ARE AT DO NOT RELOCATE THIS OVER-CURRENT DEVICE LEAST 3/8" IN HEIGHT, WORDING MUST ALSO TO BE INSTALLED ON PV DISCONNECT, w w BE WHITE ON A RED BACKGROUND. CONDUIT EVERY AND UTILITY SERVICE5. VERIFY PROPER GROUNDING ELECTRODE SYSTEM NEC 690.31(G)(3)8690.31(B) z IN ACCORDANCE WITH NEC 250.50. WARNING- N 6. ANY WHITE/NEUTRAL CONDUCTOR USED AS A o o PHASE CONDUCTOR SHALL BE RE-IDENTIFIED DATE: y2018 O PHOTOVOLTAIC POWER SOURCE USING RED TAPE AT ITS TERMINATION POINTS. M TAPE SHALL BE APPLIED IN ANY LOCATION JOB NO: 75842 TO BE INSTALLED AT THE UTILITY/METER o 0 NEC AT 2 - WHERE CONDUCTOR IS VISIBLE AND ACCESSIBLE REVISION NO: 001 690 PV UTILITY DISCONNECT G IN ACCORDANCE WITH NEC 200.7(C)(1). DESIGN BY: CKP LOCATED IN GARAGE O 7. ALL ELECTRICAL EQUIPMENT SHALL COMPLY WITH O O THE WORKING CLEARANCE REQUIREMENTS DEFINED IN NEC 110.26. 5 OF 6 BILL OF MATERIALS MINIM QTY. ITEM # DESCRIPTION DESIGN REMARKS FIELD REMARKS X.L Q 20 P-Silfab310 SILFAB 310W PANEL D0 0 20 030-07758 ENPHASE IQ6+ MICROINVERTER 20 242-92093 SNAP N RACK MLPE RAIL ATTACHMENT KIT Q iy SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE, 1 053-00225 ,� AC/DC-SD-786-3R if) 45 1 242-01104 SNAP N RACK JUNCTION BOX R ((6i 112 242-92051 BLACK L FOOT, BLACK GALV FLASHING,AND BASE KIT s 112 STAINLESS STEEL LAG A304 746"x 3 Jr 2 HITCH CLIPS 0 052-10112 ENPHASE 0 CABLES 240 (PORTRAIT); PER CONNECTOR 20 052-10113 ENPHASE Q CABLES 240 (LANDSCAPE); PER CONNECTOR 0 300-07706 ENPIiASE Q WATER TIGHT CAP co4 300-07707 ENPHASE Q BRANCH TERMINATOR o N O 7 b-- :v 24 232-01067 SNAP N RACK STANDARD RAIL, 122", BLACK 0 ' C8 1?)o O a 0 232-01069 SNAP N RACK STANDARD RAIL, 162", BLACK 0' o° OC Lu a =v 16 242-04015 SNAP N RACK BONDING STANDARD RAIL SPLICE KIT, BLACK (D 21g w I— J >N U I= cc Q a= 32 242-020532 SNAP N RACK BONDING MID CLAMP, 1.18"-1.48", BLACK O Iw �c 16 232-01023 SNAP N RACK STANDARD RAIL END CAP N U Q g o, OwC 0 M (9)w 16 242-02215 SNAP N RACK UNIVERSAL END CLAMP w Z u- O , M O DL as 4 242-02101 SNAP N RACK GROUND LUG R - 6-12 AWG to m o= SEE SHT 5 LABELS _ m`o I— -°m 0 300-07701 0 `o ul ENPHASE IQ ENVOY COMMUNICATIONS GATEWAY m vo PVC 12X12X4 0 PVC 12X12X4 M n CANTEX BOXRi u a.a 1 300-07700 ENPHASE 10 AC COMBINER BOX WITH ENPHASE IQ ENVOY v 1 CH230 CUTLER-HAMMER 30A/2P BREAKER DATE: /15/2018 JOB NO: 175842 REVISION NO: 001 DESIGN BY: CH 6 °F 6 `.4 Jr FROM TO VOLTAGE PHASE CONDUCTOR FLA(II WIRE SIZE LENGTH CIRCULAR MILS(CM) CU/AL CONSTANT(IC) VOLTAGE DROP TOTAL VOLTAGE DROP VOLTAGE DROP% TOTAL VOLTAGE DROP% Voltage Drop Equation: (2 x K x I ir D)/CM WORST CIRCUIT(1) SOLADECOUNCTION R 000)1) 240 1 Cu 5.83 12 (1) (1) (1) 0.40 0.45 0.19% 0.19% Tothl Voltage Drop: 2.66V SOLADECKNUNCTION R BOX(1) PV AC COMBINER PANEL 240 1 CU 11.67 12 48 6530 12.9 121 2.66 092% 1.11% *Total Voltage Drop 00 1.11% PV AC COMBINER PANEL POINT OF INTERCONNECTION 240 1 CU 234 10 10383 12.9 0.00 2.66 .Based offworst-case scenario (1)From Engage Techincal Brief 2.66 REJACN E.91V20E13D CM/ OF TIGARD BUILUNG DiViSION Calculating AC Line Voltage Rise for 10-Series Micros with Q Cable 106+Internal Voltage Rise IQ 6+Microinverters per Branch(portrait) 1 2 3 4 5 6 7 8 9 10 11 12 13 VRise(V) 0.02 0.06 0.12 0.20 0.30 0.41 0.55 0.71 0.89 1.08 1.30 1.54 1.79 Vrise(%) 0.01 0.02 0.05 0.08 0.12 0.17 0.23 0.30 0.37 0.45 0.54 0.64 0.75 Current(A) 1.17 2.33 3.50 4.67 5.83 7.00 8.17 9.33 10.50 11.67 12.83 14.00 15.17 IQ 6+Microinverters,)er Branch(Landscape 60-cell) 1 2 3 4 5 6 7 8 9 10 11 12 13 VRise(V) 0.03 0.09 0.18 0.30 0.45 0.64 0.85 1.09 1.36 1.67 2.00 2.36 2.76 Vrise(%) 0.01 0.04 0.08 0.13 0.19 0.27 0.35 0,45 0.57 0.69 0.83 0.99 1.15 Current(A) 1.17 2.33 3.50 4.67 5.83 7.00 8.17 9.33 10.50 11.67 12.83 14.00 15.17 IQ 6+Microinverters ler Branch(Landscape 72-cell) 1 2 3 4 5 6 7 8 9 10 11 12 13 VRise(V) 0.03 0.10 0.21 0.35 0.52 0.73 0.98 1.26 1.57 1.92 2.30 2.72 3.17 Vrise(%) 0.01 0.04 0.09 0.15 0.22 0.31 0.41 0.52 0.65 0.80 0.96 1.13 1.32 Current(A) 1.17 2.33 3.50 4.67 5.83 7.00 8.17 9.33 10.50 11.67 12.83 14.00 15.17 Determining VRise within a Microinverter Branch Circuit It is not difficult to determine VRise within the microinverter branch circuit.The following diagram represents a 240 VAC system with a fully populated end-fed branch circuit of IQ 6+Micros.It illustrates how voltage measured at an individual microinverter increases by position in the branch circuit.As the number of microinverters in a branch circuit increase,the voltage at each microinverter rises in a non-linear manner. 1 2 3 45 12 13 13 240 Vac _" _ U........ 1W..� Q Aggregator +0.26V +0.24V +0.22V +0.20V +0.18V +0.04V +0.02V 240.26V 240.50V 240.72V 240.92V 241.10V 241.77V 241.79V The top row of numbers is the incremental voltage rise from one microinverter to the next,and the bottom row is the cumulative line-to-line voltage overall. The following graph illustrates how the number of microinverters connected to a portrait-oriented Q Cable causes a non-linear voltage rise when operating at 240 VAC. 7 ©2017 Enphase Energy Inc.All rights reserved. February 2017 ., i Snc „.,- SnapNrack. R EC E I VE Solar Mounting Solutions JAN 9 20V3 CITY OF Ttt r) ,1,1!):4'.:‘,''t Z''''''‘' .-.! Series 100 Residential Roof Mount 'system The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In” hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules _, ,,- i • All bonding hardware is fully integrated `` • Rail splices bond rails together, no rail jumpers required • No drilling of rail or reaching for other tools required , t ��''. • Class A Fire Rating for Type 1 and 2 modules System Features Include Snap in Single Tool Hardware Installation Easy No Cutting Leveling or Drilling t j 1 kt, AV OL Integrated Wire Preassembled m Management hardware Integrated bonding UL 2703 Certified Resources snapnrack.com/resources X Design snapnrack.com/configurator x Where to Buy snapnrack.com/where-to-buy rack Solar Mounting Solutions Series 100 Flashed L Foot Kit SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting, watertight seal over the life of the system. The Flashed L Foot provides a fully flashed roof fastener for attachment to composition roof with no required cutting of shingles. The L Foot is engineered for maximum adjustability for a clean, level installation. • Slotted attachment provides 1" vertical adjustability for array leveling • 1" spacers available for increased elevation adjustability • Offered in silver or black anodized aluminum. Both are available with black galvanized steel or aluminum flashing. • No cutting of shingles 242-92051 Features Include k x ,*�y.`� Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling UL41, Preassembled hardware Integrated bonding UL 2703 Certified Resources snapnrack.com/resources Design snapnrack.com/configurator 0 Where to Buy snapnrack.com/where-to-buy Snap , !: rack�,[ t AIWIWNIY*4'Near,' Solar Mounting Solutions . �` � Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions 5/16-18 Black Oxide ittiStainless Steel Flange Nut SnapNrack Composition Flashing -- 34 .10' SnapNrack Composition Z2 L-Foot Base SnapNrack Bonding �� 00 Channel Nut tit. 1110 441.1111 - 5/16-18 x 1-1/4" SnapNrack 92 Degree L-Foot, Stainless Steel Silver or Black Anodized Flange Bolt FLASHED L FOOT KIT TECHNICAL DATA i 2` ,ec k�-a r 1. r r .' -rte � s.44'`iti- !6 : " ATOS ,�.-"".�§.;..'` ? - a.is --�- a. 3 - n x -, ..u`-�. "'da'«,Via. 4 .�.e-'-A..,q,"Tf - -tIVR .h"g`=S` ,.. "` 'VM:2 '" z � u ekk t s .; a: -`i ;..-? . x',-,.,�, `V, AI ," a; .s� .,.,, 8 !t-”i# ;off #. :7 s Begg at 7Ara .. - i4.a k s :914.401-24` Material Finish Silver or black anodization gyp } # , ' , # 04:s ¥ - ,. �` , '�'- `2 "3 e r° ,.,, -r x�,, ' '.,-.A 4 s i-i "#_ - '' f -y, ' • Flange nut: 10-16 ft-lbs Torque Specification • Rail attachment: silver hardware 10-16 ft-lbs, black hardware 8-10 ft-lbs 877-732-2860 1 www.snapnrack.com 1 contact@snapnrack.com @ 2016 by SnapNrack Solar Mounting Solutions.All rights reserved SnapfhadcAasFedl Foo[Aoclx,rel0 NOTES: REVISION: —5/16" LAG BOLTS MUST EMBED _— 2.5"INTO ROOF STRUCTURAL MEMBERS/RAFTERS —STEP 3; PLACE L FOOT — —TORQUE ALL 5/16"HARDWARE TO _ON TOP OF FLASHING SNAPNRACK THE FOLLOWING: — COMPOSITION L FOOT —SILVER S.S. 10-16 FT—LBS AND TIGHTEN NUT CAN BE MOUNTED IN 5 -BLACK S.S. 7-9 FT—LBS ANY ORIENTATION is S.S. FLANGE NUT - RAILS CAN MOUNT TO EITHER SIDE STEP 2: SLIP FLASHING OVER SNAPNRACK A X 1"(OR 1.25") OF L FOOT(UPSLOPE VS DOWNSLOPE) '.\, L FOOT BASE AND UNDER ROW S.S. BOLT AND CHANNEL NUT OF SHINGLES ABOVE SPLIT WASHER M� `\`\, �! ''',0i.- O " LAG SCREW WITH SNAPNRACK .....41P",2 FLAT WASHER STANDARD RAIL EMBEDMENTIS STANDARD SNAPNRACK COMPOSITION =,, ROOF FLASHING STEP 1: BOLT L FOOT BASE TO ROOF WITH LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. 4°, _____. 1 t ` Iiiii ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3"USING UP TO TWO LEVELING SPACERS AS SHOWN IN "SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION RAFTER TYP. ^��(�()���n MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters SCALE: DNS PART NUMBER: DESCRIPTION: W \\11 IUl1/]� --,,,,,L,„...,,,,,,,,,,,,..,,,-- DRAFTER: D Ryan DETAIL 01 FLASHEDREV PV r�®anu�tmnog� Poo EMo. DATE: S100 PEN D01 PEN L FOOT TO a.r>, APPROVED BY: 120113 RAFTER F System Ground Methods Include: All SnapNrack Module Clamps contain 0 SnapNrack Mid Clamp a SnapNrack Bonding 0 SnapNrack Universal End Clamp Channel Nut in assembly ` • 0 SnapNrack X Clamp to properly ground the 4 0 SnapNrack Bonding Lug system (except Universal " 0 Ilsco Bonding Lug End Clams) . - s 5�F� � SnapNrack Bonding Lug Assembly 0 SNAPNRACK STANDARD RAIL SNAPNRACK BONDING CHANNEL NUT 5/16-16X1IN- STAINLESS BOLT 5/16 IN STAINLESS COPPER WIRE,TYP. SPLIT LOCK WASHER SNAPNRACK GROUND LUG,6-12AWG Ilsco Bonding Lug Assembly #10 NUT WITH STAR WASHER SNAPNRACK STANDARD RAIL DRILL i6"TO a'HOLE #10 STAINLESS BOLT (FOR#10 FASTENER) ILSCO GBL-4DBT GROUND LUG COPPER WIRE,TYP. 39 SnapNradcI¢ Solar Mounting Solutions a _ � tiaitre*m-,, ��s r Stainless Bolt with IF__Stainless SteelSt �� Split-Lock Washer Bolt with Split- Bonding Splice Standard Rai—I—1 Lock Washer Insert 015-09816 Bonding Adjustable End Clamp Top or Bonding Splice Mid Clamp Base 4 Bonding Adjustable Bonding End Clamp Bottom BondingChannel Nut Channel Nut Stainless Stainless Hardware with Bolt with .'..3 •... Bonding Adjustable Split-Lock Washers Split Lock End Clamp ` Bonding Mid Clamp `_ Bonding Standard Washer 242-02062 242-02053 Rall pe _' Ground Lug 242-04015 242-02101 12-6 AWG Copper Wire Ground Lug Assembly _, (ONE REQUIRED PER ROW OF MODULES) Universal End Clamp(UEC) Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer Universal End Clamp 242-02215 Standoff—0 N Clamp Assembly • Rubber Nut S Rain Collar Serrated Stainless Channel Channel Nut Steel Flange Nut Stainless Serrated Stainless Flange Nut Mill Finish Steel Flange Bolt 92 Degree Stainless Standoff L Foot Flange Bolt All Purpose L Foot Mill Finish Standoff Base(1-Hole Metal Roof Base Shown) Mill Finish L Foot Base Assembly L Foot Base Flashing s.. Standoff _ ` L Foot Base with Flashing ` Metal Roof Base 242-52052 242-92050 with L Foot 242-0203] SERIES 100 TECHNICAL DATA +, - $ ,•: " ,, em (bs1daEr - 1r : 't s oN .s «k-- . ms ` � 4'-m _; -rtft Of*SS,„ ri - h , c -'rxrefr, a. ' ~ - . , , - �, x .Auavtrx .g. -EifN 'iti € fYr 3. - gV lle tt,n rtx a : a € C_ ;; �, . 3- s .. ,v ` r� o �x , : a tt tr - Ias its rr� 1 "SittgW . .9, r .,.w' u s = ' " . e 'Yse. � ,« �#a -« _..,_... ,�ar . w . s _ -,.. .. 'o_ • Silver and black anodized aluminum Material Finish • Mill finish on select products • Silver or black coated hardware AtatatiattiOnfeevagg egit' .. " r -r `oYs :, -".�`k e" 3r + � st xNote Appearance of mill finish products may vary change ovtme3 , .� 4-.-,,,,-----4.7-,- -c � ' `-4it '4i � T. ems-3Ytr3 �� ,� .iL - g- , A„ � w n� a� y'� � ? ��" N .} : I ,--"': qxr- S t ' 1 thto sr«-md " -+ �� `.-,, ' ;kr '' � > - r. � iti Snow Loads 0 -120 psf ti-K : ..' a€ -a +tee v r `' ` 877-732-2860 1 www.snapnrack.com Icontact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions.All rights reserved SnapNrackSeries_100_Brochure_2.1 MID CLAMP ASSEMBLY / iv__.. Ill \ \ / INN '- '- - Tr SS BONDING PIN \ = MODULE / ` =� FRAME tiptl\ / RAIL \ / _ f`� CHANNEL NUT NOTE: 1. ADWSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL L-12 AWG BARE 5rIL'-18 SS BOLT COPPER WIRE SS SPLIT LOC❑WASHER ' (TORE UE TO 1❑FT-LBS) / \-- \\ 1111111SNAPNRAC❑ GROUND LUG `7= \ / 'Atillin iriii-Ok MM.._ \\ 1` // I ` -.'-'-'••• 111PCHANNEL NUT 44.0.11ip I SS BONDING r RAIL PINS NOTE: 1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL 5. ENSURE SPLIT LOC❑WASHER IS INSTALLED ON TOP OF COPPER WIRE INSPECTOR: DESCRIPTION: DRAWN BY: M HMI Mimi SNAPNRAC❑ MOUNTING SYSTEM APPROVED BY: I III III II I Mm SnapNrack- REVISGROUNDING DETAILS O1 NEW ITEM Solar Mounting Solutions SD1rCh S®LLC PART NUMBER: SCALE: 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA PHONE(415)580-6900•FAX(415)580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY.ANY - REPRODUCTION,DISCLOSURE.OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNiUN SOUTH LICE S ,laDeck FLASHED PV ROOF-M00NT COMSINERV NCI0SURE Basic Features • Stamped Seamless Construction • 18 Gauge Galvanized Steel • Powder Coated Surfaces • Flashes into the roof deck • 3 Roof deck knockouts .5", .75", 1" • 5 Centering dimples for entry/exit r N fittings or conduit • 2 Position Ground lug installed • Mounting Hardware Included SolaDeck Model SD 0783 SolaDeck UL50 Type 3R Enclosures Available Models: Model SD 0783-(3"fixed Din Rail) Model SD 0786-(6"slotted Din Rail) SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated-600VDC, 120AMPS Model SD 0783-41 3" Fixed Din Rail fastened using Norlock System **Typical System Configuration 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 1-Power Distribution Block 600VDC 175AMP 1-Bus Bar with UL lug Model SD 0786-41 6"Slotted Din Rail fastened using steel studs **Typical System Configuration 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 4-Din Rail Mounted Terminal Blocks Bus Bars with UL lug **Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders,600V 50 AMP *E 90C for rail mounted terminal blocks and 600 V 175 AMP 90C for Power Distribution Blocks. Use Copper Wire Conductors. s of Cover is trimmed to allow Model SD 0783-41,wired with conduit or fittings,base is Model SD 0786-41,wired with center dimpled for fitting Din Rail mounted fuse holders, Din Rail mounted fuse holders, locations. bus bar and power distribution terminal blocks and bus bars. block. RSTC Enterprises, Inc • 2219 Heimstead Road •Eau Cliare, WI 54703 For product information call 1(866) 367-7782 w . Part No. 242-01104 Materials Included o (1) SnapNrack Junction Box Body !" "�"� 4!) !,0 0 (1) SnapNrack Junction Box Lid w/Gasket 0 (1) 5/16"-18 X 1-1/4" SS HCS Bolt � 0 (1) SnapNrack Channel Nut 0 •j l -gm. Nur O (1) 5/16"-18 X 1" SS HCS Bolt O (1) 5/16"-18 Self-Retaining Washer 1• • Hardware Description Torque Specification (lb-ft) I� Junction Box Channel Nut 5 lb-ft (60 lb-in) \_ 02 Junction Box Lid 3 lb-ft (36 lb-in) Technical Specifications Internal Dimensions 5.5" x 4.5" x 3.2" (inner box area) Material Box: Polycarbonate Gasket: Rubber UL Environmental Rating Type 4X (NEMA 4X) Certifications UL50 Temperature Range -40°F - 185°F (-40°C - 85°C) Compatibility Box Mount: S100 Standard Rail, S200 Ground Rail Internal Mount: Type 0 DIN Rail 2.11" ir IX 4.31" I 1017: o; J O 6.10" 7.76" 7.01" 4I 6.10 0 M � Data Sheet Enphase Networking Enphase The Enphase IQ CombinerT" with Enphase IQ Envoy"' consolidates interconnection equipment into a IQ Combiner single enclosure and streamlines PV installations by (X-IQ-AM1-240-B) providing a consistent, pre-wired solution for residential applications. Smart • Includes IQ Envoy for communication and control i .4, • Flexible networking supports Wi-Fi, ;' Ethernet,or cellular Simple r 4 • Three pre-installed 20 A/240 VAC ± ,t -; circuit breakers 44„ • Provides production metering and .. ,. consumption monitoring. �: $'' Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty UL LISTED ENPHASE E. To learn more about Enphase offerings,visit enphase.com Enphase IQ Combiner MODEL NUMBER IQ Combiner X-IQ-AM1-240-B IQ Combiner with Enphase IQ Envoy'"for integrated revenue grade PV production metering (ANSI C12,20+-1-0.5%)and optional consumption monitoring(+/-;2.5%). ACCESSORIES(order separately) Enphase Mobile Connect' Plug and play industrial grade cellular modem with five-year date plan for systems up to 0 CELLMODEM-01(3G) microinverters.(Available inthe US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMOD€M-034G" ) where there is adequate cellular service in the installation..area.) Consumption Monitoring CT Split core current transformers enable whole home consumption metering(+/-2.5°t), CT-200-SPLIT ELECTRICAL SPECIFICATIONS Rating Continuous duty Solar branch circuit breakers Three 2-pole 20A/240 VAC DIN rail-mounted breakers Maximum system voltage 240 VAC Rated output current 48 A Rated input current,each input 16.A Maximum fuse/circuit breaker rating(output) 60 A Production Metering CT 200A solid core pre-installed on solar bu*sbar and wired to IQ Envoy MECHANICAL DATA Dimensions(WxlxD) 38.0 x 38.7 x 20-3 cm(15.0"x 15.3"x'8:0 ) Weight 5.1 kg(11.2 lbs) Ambient temperature range : -40°C to a-46'* (40°TO 115°F.) ... Cooling Vented,natural convection,plus heat shield Enclosure environmental rating.: ' Outdoor,"Nf TL certlfed,NEMAtype; RR,polycarbonate construction ."' Wire size 14 to 6 AWG copper conductors for branch inputs. 14 to 4 AWG copper conductors for combined output. Follow local code requirements for conductor sizing. Altitude INTERNET CONNECTION OPTIONS Integrated Wi-Fi. Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable-riot included CellularOptional,CELLM € M-aj ( C);orCELLMODEMM-03(40)-hot included COMPLIANCE Compliance,.Combiner Compliance,IQ Envoy UL 916 CAN/CSA C22.2 No.61010-1 47 CFR,Part 15,Class B,ICES 003 IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 Metering:ANSI C12.20 accuracy class 0.5 To learn more about Enphase offerings,visit enphase.com :;�2017 Enphase Energy.All rights reserved.All trademarks or brands o this document are registered by their respective owner a ENPHASE, Data Sheet Enphase Microinverters Enphase Designed for higher powered modules,the smart grid- ready Enphase IQ 6 Micro'' and Enphase IQ 6+ Micro' IQ 6 and IQ 6+ are built on the sixth-generation platform and achieve the highest efficiency for module-level power electronics Microinverters and reduced cost per watt. Part of the Enphase IQ System,the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ EnvoyTM Enphase IQ BatteryTM,and the Enphase EnlightenTM monitoring and analysis software. The IQ 6 and IQ 6+ Micro are very reliable as they have fewer parts and undergo over 1 million hours of testing. Enphase provides an industry-leading warranty of up to 25 years. Easy to Install • Lightweight • Simple cable management • Built-in rapid shutdown(NEC 2014) Owl" Productive • Optimized for high powered modules • Supports 60 and 72-cell modules • Maximizes energy production Smart Grid Ready • Complies with fixed power factor,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles CERTIFIED SAFETY us EA E341165 EN PHAS E To learn more about Enphase offerings,visit enphase.com U Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W-300 W 235W-400tN+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 62 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 161 =48 V 16 V-62.V Min/Max start voltage 22 V/48 V 22 V/62 V Max DC short circuit current(module tsc) 15 A 15 A Overvoltage class DC port II II DC port backfeed under single fault 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ6-60-2-US AND 1Q6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Peak output power 240 VA 290 VA Maximum continuous output power 230 VA 280 VA Nominal voltage/range2 240 V/211-264 V. 208 V/183-229 V 240 V/211-264 V 208 V/183-229 V Nominal output current 0.96 A 1.11 A 1.17 A 1.35A Nominal frequency 64 Hz 60 H7; Extended frequency range 47-68 Hz 47-68 Hz Power factor at rated power 1;0 0 Maximum units per 20 A branch circuit 16(240 VAC) 13(240 VAC) 14(208 VAC) 11 (208 VAC) Ov rvtai ege cl ss AC.port; ", Itf: III , AC port backfeed under single fault 0 A 0 A Power factor adjustable g 1/0.7;leadt �" 1 7 leading '6.7 le rn �:.: EFFICIENCY @240 V @208 V @240 V @208 V SEC weighted efficiency leading. ti a ,, �5-5 Vin.. 970'�k` 9f 5"�:m MECHANICAL DATA Ambient temperature range -40° to a 6a°C Relative humidity range 4°i to 100. (condensing) Connector f y'Pe : . A4C4-Or Ampberiol 4U X Dimensions(WxHxD) 219 mm x 191 mm x 37.9 mm(without bracket) Cooling Natural convection-No fans Approved far met locations Pollution degree PD3 Environmental DV exposure rating .Outdoor NEMA 250,type 6(iP+7) FEATURES - Communication `; :; : Pieter line .' Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy ompliance UL 62109-'1,UL1'741/1EEE1 t47 FCC, Pert 15 Class:B 4CES-0003'Class B, CAN/CSA C2 2 NO 1071 til TWO product is UL Listed as PV Rapid Shut Down Equipment and;conforrms with #E 2tl Y4 and ' NEC-201/Section 690.12 and C22,1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC agd'DC condticiors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings,visit enphase.com O 2016 Enphase Energy.All rights reserved.All e-ademarks or orands used are the property of Enphase Energy,Inc 2°1'-°216 ENPHAS Ez CERTIFICATE OF COMPLIANCE Certificate Number 20161220-E341165 Report Reference E341165-20161210 Issue Date 2016-DECEMBER-20 Issued to: ENPHASE ENERGY INC 1420 N McDowell Blvd Petaluma CA 94954-6515 This is to certify that STATIC INVERTERS, CONVERTERS AND representative samples of ACCESSORIES FOR USE IN INDEPENDENT POWER SYSTEMS, PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT Permanently-connected, utility Interactive, single-phase, distributed resource power system, Models IQ6PLUS-72-2- US, IQ6PLUS-72-5-US, IQ6-60-2-US, IQ6-60-5-US, IQ6PLUS-72-ACM-US and IQ6-60-ACM-US. Photovoltaic Rapid Shutdown Equipment, Models IQ6PLUS-72-2-US, IQ6PLUS-72-5-US, IQ6-60-2-US, IQ6- 60-5-US, IQ6PLUS-72-ACM-US and IQ6-60-ACM-US Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: See addendum page Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. (11) Bruce Mahrenholz,Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL.For questions,please contact a local UL Customer Service Representative at htta://ut.conJaboutuVbcations/ Page 1 of 2 Created by UL Document Assembler 2016-12-21 18:09:30 -06:00 CERTIFICATE OF COMPLIANCE Certificate Number 20170112-E486080 Report Reference E486080-20160830 Issue Date 2017-JANUARY-12 Issued to: ENPHASE ENERGY INC 1420 N McDowell Blvd Petaluma CA 94954-6515 This is to certify that DISTRIBUTED GENERATION WIRING SYSTEMS AND representative samples of HARNESSES Photovoltaic Wiring Harness. Models 840-00387 or Q-12- 10-240, 840-00388 or Q-12-17-240, 840-00389 or Q-12-20- 200, 840-00800 or Q-DCC-7, 840-00386 or Q-DCC-5, 840- 00385 or Q-DCC-2. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: UL Subject 9703 - Outline of Investigation for Distributed Generation Wiring Harnesses Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. dadvoilligAT 110) Bruce nholz,Director h American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)many authorized licensee of UL.For questions,please contact a local UL Customer Service Representative at http://ul.coMaboutul/locations/ Page 1 of 1 CERTIFICATE OF COMPLIANCE Certificate Number 20161220-E341165 Report Reference E341165-20161210 Issue Date 2016-DECEMBER-20 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Standard(s)for Safety: UL1741, INVERTERS, CONVERTERS, CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY RESOURCES IEEE1547, IEEE STANDARD FOR INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS IEEE1547.1, IEEE STANDARD FOR CONFORMANCE TEST PROCEDURES FOR EQUIPMENT INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Bracenholznholz,Director American Certification Program (11Z) UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized accuses of UL.For questions,please contact a local UL Customer Service Representative at http://utcom/aboutuabcations/ Page 2 of 2 Created by UL Document Assembler 2016-12-21 18:09:30 -06:00 ' ' '''- , y ......1:.:„.:_:_ ,, , : ,irk.t, ..____ _ . SLA .. m .., � � ' ,,:ilfa 6 . „ Monocrystalline , ..,„ ...„ ,., Los Angeles•'T •Minneapolis AAA igni JUST TIER 1 • TARIFF -IN- DNV BANKABLE * •////f FREE11== ArOMATETED TIME TESTED $$$ 10'00 HIGH � r 310 Wp 100% MAXIMUM POWER DENSITY Silfab's SLA-M 310 ultra-high-efficiency modules are optimized for both Residential and Commercial projects where maximum 60 Cell power density is preferred. 100% NORTH AMERICAN QUALITY MATTERS Monoerystall ine Silfab's fully-automated manufacturing facility ensures precision engineering is applied at every stage.Superior reliability and performance PV Module combine to produce one of the highest quality modules with the lowest defect rate in the industry. NORTH AMERICAN CUSTOMIZED SERVICE (� Silfab's 100%North American based team CE IEC ! 1 �Ti ) a_, riFraunhofer leverages just-in-time manufacturing to deliver °14h ' unparalleled service,on-time delivery and flexible project solutions. ENSURES MAXIMUM EFFICIENCY 44 PPM DEFECT RATE* 60 of the highest efficiency,premium quality monocrystalline Total automation ensures strict quality control during each cells result in a maximum power rating of 310Wp. step of the process at our certified ISO manufacturing facility. ADVANCED PERFORMANCE WARRANTY *As of December 31,2016 25-year linear power performance guarantee to 82% LIGHT AND DURABLE Over-engineered to weather low load bearing structures up ENHANCED PRODUCT WARRANTY to 5400 Pa.Light weight frame exclusively designed with 12-year product/workmanship warranty wide-ranging racking compatibility and durability. BUILT BY INDUSTRY EXPERTS PID RESISTANT With over 35 years of industry experience,Silfab's technical team are pioneers in PV technology and are dedicated to an Proven in accordance to IEC 62804-1 innovative approach that provides superior manufacturing AVAILABLE IN _ processes including:infra-red cell sorting,glass washing, All Black automated soldering and meticulous cell alignment. ... i • (��,► D ' •e.:. ,Q: :S OLAc TNAMS .Proud Partner 1 1 Electrical Specifications Test Conditions SILFAB SLA Monocrystalline SIC Module Power(Pmax) N 34T Wp 3113 Maximum power voltage(Vpmax) V 234 .--- 33.05 29.7 ,_..._. Maximum power current(Ipmax) A 9.33 Open circuit volts a Voc 7.88 �� _� 40.25 37.2 Short circuit current(Isc) "^` A 9 93 Module efficiency 8.14 19.t1 �17.9 __-- Maximum system voltage(VDC) V Series fuse ratin• A 5 115 1000 - Power Tolerance Wp Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25"C•NOd 800 W/m'•AM 1.5•Measurement uncertainty-34b +/-5 •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by+/-5. Temperature Ratings SILFAB SLA Monocrystalline Temperature Coefficient Isc %/K y.,. 0,0 Temperature Coefficient Voc 0 %/K -0.30 Temperature Coefficient Pmax %/K NOCT(±2°C) °C 4 45&5 - Operating temperature Mechanical Properties and Components ei: SILFAB SLA Monocrystalline Module wei:ht(±1 k:) k: ' 19 Dimensions(H x L x D;±1mm) mm Maximum surface load(wind/snow)* N/mt 1650 x 990 x 38 Hail impact resistance 54000 Cells 0 25 mm at 83 km/h 60-Si monoc :taUlne•3.or 4 bUsbar-156.75 it 156,75 mm" BGlass 3.2 mm hi:h transmittance,tem.ered,antireflective coatin: acksheet Frame Multila er ol ester-based Bypass diodes Anodi dAl' Cables and connectors(See installation manual) 3 diodes-45V/12A,IP67/IP68 .1200 MITI 0 57 rnrt`1'(4 Ehkrrf2,jV1t4Coni.-tibl&, " , Warranties Module product warranty SILFAB SLA Monocrystalline 25 years Linear power performance guarantee 97%end of 1 year 90%end of 12°year _>82%end of 25"year Certifications SILFAB SLA Monocrystalline Product ULC ORD C1703,UL 1703,IEC 61215,IEC 61730,IEC 61701,CEC listed Facto� UL Fire Ratin::T .e 2(T .e 1 on re.uest) ISO 9001 x2008 Warning:Read the installation and User Manual before g handling,installing and operating modules. D _ a� rolna•e n. Third-party generated pan files from PV Evolution Labs available I FR Gr°Hole mm�. a E for download at:www.silfab.ca/downloads _.e Pallet Count:up to 25 per pallet ,x„ a °_3 Container Count:900 MounRng sla TO 0 c.c Profile view S iIfab 0 SOLAR II Gr tling II All n,,.,:it in mm U, v Silfab Solar Inc. role '°'em^°.:.,mm Hole tolerances:l°.fmn ax4gs,KK to sole 240 Courtneypark Drive East•Mississauga,Ontario Canada L5T 2S5 Tel+1 905-255-2501•Fax+1 905-696-0267 I °° I info@silfab.ca•www.silfab.ca 1' �� 1 1 Construction Contractors Board g \!11'\4'orewn.Lo\ CCI) • Kate Brim n.Governor Mailine Address: PO trio.\ 14140 Salem.OR 97;09-5052 Phone ~ 503-378-4621 CCB LICENSE DETAIL REPORT LICENSE: 212831 GENERAL INFORMATION AURIC SOLAR LLC LICENSE STATUS: Active 2310 SOUTH 1300 WEST FIRST LICENSED: 11/16/2016 SALT LAKE CITY UT 84119 LICENSE EXPIRES: 11/1612018 801-878-3363 ENTITY: Limited Liability Company IND. CONT. STATUS: Nonexempt ENDORSEMENTS ADDITIONAL CERTIFICATES/LICENSES COMMERCIAL: CSC1 -Specialty Contractor 1 CERTIFIED HOME INSPECTOR: NO RESIDENTIAL: RSC-Specialty Contractor LICENSED LEAD BASED PAINT: NO ASSOCIATED NAMES THANIEL SHAFFER BISHOP, RMI Owner JESS SCOTT PHILLIPS, Member(Limited Liability Company) ROBERT TYLER GORDON, Member(Limited Liability Company) THANIEL SHAFFER BISHOP,Member(Limited Liability Company) TRENTON JAY VANSICE, Member(Limited Liability Company) RESIDENTIAL BOND INFORMATION COMPANY: CINCINNATI INSURANCE COMPANY(THE) AMOUNT $ 15,000 EFFECTIVE TO: 11/16/2018 COMMERCIAL BOND INFORMATION COMPANY: CINCINNATI INSURANCE COMPANY(THE) AMOUNT: $ 50,000 EFFECTIVE TO: 11/16/2018 INSURANCE INFORMATION COMPANY: AUTO OWNERS INS CO OCCURANCE/AGGREGATE AMOUNT: $1,000,000/$2,000,000 CANCELLATION DATE 09/10/2017 OTHER LICENSE NUMBERS This report was generated by the CCB on: November 16,2016, 1:40 pm