Loading...
Permit (55) CITY OF TIGARD MASTER PERMIT a COMMUNITY DEVELOPMENTIN Permit MI MST2017-00352 Date Issued: 02/05/2018 T i u A it[) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S102CB03600 Jurisdiction: Tigard Site address: 10010 SW GARRETT ST Subdivision: FREWING'S ORCHARD TRACTS Lot: 10 Project: HAUPT Project Description: New basement window for remodel. Add bathroom, laundry room, bedroom and sitting room. All trade work is being done under separate permits. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 775 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Yes Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $5,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'l 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT COM VB R-3 0 Owner: Contractor: HAUPT,ROBERT ADAM OWNER Required Items and Reports(Conditions) 10010 SW GARRETT ST ADAM HAUPT TIGARD,OR 97223 1006 SW GARRETT TIGARD,OR 97223 PHONE: PHONE: 971-222-4898 FAX: Total Fees: $266.06 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit wit expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through P.952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1,.800.332.2344. Issued By: (" _ Permittee Signature: ' -- Call 503.639.4175 by 7:00 a.m.for the next available inspectio "date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential _ FOR 0111( 1. 1 s►.011.1 " ° ,,V , ',Received City of Tigard `'G t i Permit No.: > 1111 " 13125 SW Hall Blvd.,Tigard,OR 97223 """" '� Date/By. ijj �� M / �/ `( �3 5C g Plan Review Other Permit: I Phone: 503.718.2439 439 Fax: 503.598.1960 P, 4 1 1 Date/By: )o— 11 — l'I G A K D Inspection Line: 503.639.4175 " Date Ready/By: //� J ® See Page 2 for Internet: www.tigard-or.gov �q Noti d/Me od:.l /7 . I Supplemental Information TYPE OF WOl 1ILD%NG LJtV lS1 REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all E]Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. IV 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ 5"Cxz: ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: I vv i d i c(z k1 New dwelling area: 7 '2 s'ivare feet City/State/ZIP: 1 4�� CJr� -1 Z Z� Garage/carport area: square feet Suite/bldg./apt.no.: Project name: ,yrr Covered porch area: square feet Cross street/directions to job site: (f,kr",-h .,' , . A ( `7 ;,✓, Deck area: square feet It Yt'l.'►u, e aE F a c- 91 :_. Other structure area: square feet V /Grr'n 1, � e y�X� / yk, REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WQRK work indicated on this application. i A.),.- 1.„4".,.(..„...-k- (�-w„_,�it.x-1 ; .1kitt, '1 w;W,I.Gvv' far rcey@I41 Valuation: $ r • l •4 f!t7"7f,Lf "l C' ,f L4'u/v %2 -efl Existing building area: square feet ,////// 443- .E.. ./2-6- f fr r y. New building area: square feet 2) PROPERTY OWNER 774E- "egeF. r I J 7. Number of stories: Name: A/ p-p,4/lit, :..5 c-7.94-)7r- /-11:).1,-//7.:15 Type of construction: Address: (r.)0(O £,ti. C..--kewrc.f-fi --ft-4V— Occupancy groups: City/State/ZIP: 1 00.- Z 1 L 2-3 A/41 - l Existing: Phone:( ) Fax:( ) ,L) - j1-/9972E,(2_ '� �� ( LZZ- ��'�� �. New: 0 APPLICANT 0 CONTACT PERSON / BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Structural plan review fee(or deposit): Contact name: FLS plan review fee(if applicable): Address: (g 7i) -�L[ ; � -41-4" Total fees due upon application: of 7, 34J City/State/ZIP: „ _A 1` f Phone:( ) Fax::( ) Amount received: ✓/ 10 17 PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: ail,.r-� EL.T 7 0 J�c�,I . Co:� Gl� , CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name: 111 t 1, p /- Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: Solar Installation Specialty Code checklist. City/State/ZIP: Permit Fee(includes plan review $180.00 and administrative fees): Phone:( ) Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: Total fee due upon application: $201.60 Authorized signature: / /e1„t__,__7"--------------- This permit application expires if a permit is not obtained Gwithin 180 days after it has been accepted as complete. Print name: /����� Date: �f sl//�•7 *Sme ervicemethodology set by Tri-County Building Industry I:\Building\Permits\BUP-RESPemritApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling 1 o iz o i i RI.is i.s i o y l.v City of Tigard Received Permit No.: 13125 SW Hall Blvd.,Tigard,OR 97223 Date/By: 111Phone: 503.718.2439 Fax: 503.598.1960 Associated permits: 24-Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical I'IC,ARD Internet: www.tigard-or.gov ❑ Other: 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 0 0 3 Verification of approved plat/lot. ❑ ❑ 0 4 Fire district approval required. Name of district: • H 0 0 5 Septic system permit or authorization for remodel. Existing system capacity . 0 0 6 Sewer permit. 0 0 0 7 Water district approval. 0 0 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 0 0 9 Erosion control 0 plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- 0 0 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 0 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 0 0 and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 0 ❑ floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 0 0 over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. AA A 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore on and shall be shown to be a licable to the ro'ect under review. 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 0 0 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 10010 SW GARRETT ST, TIGARD, OR, 97223 May 21 , 2018 at 1 :23:21 PM Record Type: Record ID: Residential - Master Permit MST2017-00352 Inspection Type: Inspector: 299 Final inspection David Young Result: FA I L Comments: Framing covered prior to inspection, no inspections on this permit. Provide permit for 2 fans installed without mechanical permit. Will check with previous inspectors to see if framing was ok to cover on electrical inspection. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 10010 SW GARRETT ST, TIGARD, OR, 97223 Record Type: Record ID: Residential - Master Permit MST2017-00352 Inspection Type: Inspector: 299 Final inspection David Young Result: PASS - NoCofO Comments: Basement framing covered prior to inspection appears ok per approved plans. Egress window well appears ok per stamped letter from structural engineer and approved plans. Smoke detectors installed. Floor and walls sealed per homeowner. There does not appear to be any fire, life safety issues for existing basement conversion. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 10010 SW GARRETT ST, TIGARD, OR, 97223 Record Type: Record ID: Residential - Master Permit MST2017-00352 Inspection Type: Inspector: 299 Final inspection David Young Result: PASS - NoCofO Comments: Framing covered prior to inspection appears ok per approved plans. Walls and floors sealed. Window well for egress appears ok per approved plans and engineers letter. Smoke detectors installed. There does not appear to be any fire or life safety issues with basement conversion. Violation Summary: Inspector Contractor