Report (24) • •
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: IMSI 2b1 - b01 b O Jurisdiction: � b�'i „ „ b
Site Address: 0 t•&., ()Cit.6112--art E_ "EYL(L f'rG
Subdivision/Lot#: v
and/or
Map and Tax Lot#: 0 S 3
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
400(
Signature: / 2 ZD 1 3'
'Or/Authorizedent A
Own- Gee .f✓ntrag
Print Name: ( )6 Ez4
ORSC Section Ni 107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
0 0
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, ,-,.s C..Et.pt -mss-reL.1 , am the general contractor or the owner-builder
at the following address:
Site Address: 3CA 0 G w t.A‘n-3 (',„)).s -. R.2Pkr--
City: --r` C.,A4- 6 / Si-tell,otpo 1
Permit#: MST Z Or-4- - BO 100
Subdivision/Lot#: Mb21-k W-m-r- ZhrE12 1. AP•ces
and/or
Map and Tax Lot#: 1 C3
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
_ /
Signature: -
. 12, 2.0 a4
•:
Ge Co I,'c •r Owner-:uilder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
• •
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, C LA' CH-g-gr g67, am the general contractor or the owner-builder
at the following address:
Site Address: /3 y O 5-W 43 6 7-t2g
City:
6,471---4/ sj _tvPOO
Permit#:
Mcr7ol7- - DD /av
Subdivision/Lot#: o/LTIf lJ &r 1Z,✓ z-
and/or
Map and Tax Lot#: / /3
To conform with the 2014 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement
The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting w'
Joi apped 12" at seams and
Extending up the foundation walls 12".
Signature: A%�,. � — Date:
/ 2/2.6//
CG= er.l "rcto roi Owner-Builder
I:\Building\Form\RES-MoistureBarrier.doc 09/13/2016
Form 6405 2017
Completion Certification—Site Inspection "'1 ,. t
us
New Homes Program—Single Family
i
of Oregon
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment Information
Incentive Payee Company Name: 'William Lyon Homes IIs this payment redirected?: INo
Builder or Company: William Lyon Homes Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Com
Affordable Housing No
Solar Ready Builder Incentive: No (Solar ReadyVerifier InCEINO
Site IrtformatWn
Development NW River Terr-Area 1 Townhomes Lot AZEre,, i>� Axis ID: I IREM/Rate®ID:
Address 136fili 11. -, su.a'.. _, F 11-1.11.4S11,0,
,
Street Line 2 Multi-Family 'Yes City: Sherwood State. OR Zip: 97140
Total conditioned area(sq.ft.). 1,529 House Volume: I 15,291 Housing Type: Townhouse inside
Number of Stories: 13 Number of Bedrooms: 2 Foundation Type: Slab Floor
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed None Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet..
Verification Type. Actual Model Equipment Details&Notes
Slab Perimeter Insulation R- 15.0 Slab tinder Insulation R-
Insulation Framed Floor R- 30.0 Secondary Framed Floor R- 59.0
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC:10.3 Total window area: .1211
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE: 95 Brand Rheem
Type: Gas Furnace HSPF: Model IF: R95PA0401317MSA
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Conditioned A Outdoor Unit(for heat pumps)
ECM: No Model#: I
AHRI Certificate:6464998 #of Systems 11
Gallons: 150 Brand: BradfordWhite
Water Heater Type Storage EF. 1.95 Model#: RE350T6
Water Heating Fuel Electric Location: 'Conditioned A AHRI Certificate.8105439
Ducts and Duct Location 'Conditioned %ducts inside Ij%a ',.'(Duct Leakage(CFM) 50Pa. 1p-:'; ,..as_..r.. d
Testing
Infiltration Air Changes per Hour(ACH) 50Pa: 3,91 I
Ventilation Ventilation Type HRV/ERV Model:
Supply Side-Air Cycler Airflow measured or why untestable? 'Roof Termination
Appliances
Refrigerator kWh/yr Model:
ENERGY STAR Diswasher kWh/yr 268 Model: FGID2466"'A
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH 1 Showerwand 1.5 GPH 1 Showerhead 1.6 GPH 1 IShowerhead 1.75 GPH I
Notes: