Plans (171) r • PROJECT NOTES: SYSTEM INFORMATION TABLE OF CONTENTS 1. 6.820 KW DC,6.000 KW AC SOLAR PHOTOVOLTAIC SYSTEM 2. 2 STORY COMP SHINGLE ROOF AT 25°PITCH. ARRAY PITCH MAGNETIC TRUE O S S C 3111 PAGE ORIENTATION ORIENTATION # DESCRIPTION 3. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT RUN PLACEMENT _ WITH CUSTOMER. AR-01 25° 195° 180° PV-01 SITE PLAN&MECHANICAL 4. CONTACT:S.ROOF PHONE:503-967-5786 5. DESIGN CRITERIA: 5.1. SYSTEM WEIGHT:3LBS/SQFT. OFFICE COPY TOTAL PV ARRAY AREA: 403 FT2 PV-02 RACKING LAYOUT 5.2. EFFECTIVE WIND SPEED:95 MPH 3-SEC GUST. LARGEST PV SECTION: 36.67 FT - 5.3. WIND EXPOSURE CATEGORY:B PV-03 RACKING DETAIL 5.4. SNOWLOAD:25 PSF ROOF SLOPE:25° 5.5. OCCUPANCY CATEGORY:II ROOF AREA MEASURED IN PLAN VIEW:2600FT2 PV-04 SINGLE LINE DIAGRAM PV ARRAY/ROOF AREA: 15.51 - PROPERTY LINE PLAN -SCALE: 3/64"=1'0" (R:i-iF I) (E)SERVICE ENTRANCE SITE PLAN-SCALE: 1/16"=V-0" „'7 -__-_� PL &UTILITY METER L (EXTERIOR WALL) PL �_ (E)MAIN PANEL PL (INTERIOR WALL) 3� PL 7 BUILDING.e i'tS a `� 1 r Qv SW NOVARE PLACE IIII 73 (N)SOLAR ARRAY AR-01 bp, 1 111111 lull! (N) ROOFTOP JUNCTION BOXES MI r N 1111111111 I )1 ry� • (2' II I III WEST-FACING ELEVATION -SCALE: 1/8"= 1'-0" 13 r Q- 00-00 13 OFFICE COPY 22._1. 0- CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE 0- Approved: �/I OTC: [ j / Permit#: r n_c-1-,z_el 19- n CI C) L4 -7 Address: , J i K o Novo,I,- e. ® INDICATES TSRF PERCENTAGE Suite##: ELECTRICAL EQUIPMENT LOCATIONS NTS By: Date: ., 1- i Q ` DESIGNED BY: C. BOYCE ''At--' ,� ;,�, ELEMENTAL ENERGY TOM PETERSON SITE PLAN & REV:A CHECKED BY: J. GRIESER OR CCB#: 195141 11150 SW NOVARE PLACE, TIGARD, OR 97223 PV-01 MECHANICAL 12/5/2017 F RACKING&ATTACHMENT LAYOUT-SCALE: 1/8"= 1'-0": IN-PLANE VIEW ALLOWABLE RAIL LOCATIONS SILFAB SLA 310 M AR-01 M typ.40"x 65"(Including Clamp Spacing) 7() s 1 PORTRAIT I /'' 1'-0" \ 3" 15" t O CJ I cp –e– T LANDSCAPE 23-t1" vO -- 0 \ TYP 21._8" I I I I !- 1,_4" 5 ' i 1 I I 3 " I 0 . 1 0 1 o w 0— � � - � 0 0–e– G-- >mil_.....40. i Q[ 0 —9— 3 —O 4: C3---0 –e– 0-0 --3— 0 o ---e– 0— 1-4" i _ –a'-0"_, ,2'-0", MATERIALS NOTES TO INSALLER: Max. TYPP (60) MOUNTING ASSEMBLIES _J 36'-8" / 46-0" (36) MID ANIMPPSS S (1)SOLADECKS 0 _____132"RAILS 168"RAILS 204" RAILS Z SPLICES 0 Q QSTRUCTURAL DETAILS -SCALE: 1/8"=1'-0": 6"MAX HEIGHT OF MODULES(TYP.) DRAWING KEY: _/-' <v• r------ MODULEI 12"ROOF VENT 23•-11" �/0 iii .... JUNCTION BOX . „ '- RIDGE SETBACK(1'TYP) I0.°� SOLADECK \ Aillih FIRE SETBACK(3'TYP) ENPHASE MICROINVERTER -- RAFTER ENPHASE TRUNK CABLE I Ironridge XR-10&Rail THHN IN CONDUIT o Ironridge Mount Flashing SEE WIRING SCHEDULE 05 P0-03 FOR SIZING) 2x4 MANUFACTURED TRUSSES 1s'0 X 3" LAG SCREW 24"O.C. :6 1ELEMENTAL ElssERGY DESIGNED BY: C. BOYCE ELEMENTAL ENERGY TOM PETERSON RACKING REV:A CHECKED BY: J. GRIESER OR CCB#: 195141 11150 SW NOVARE PLACE, TIGARD, OR 97223 LAYOUT PV 02 12/5/2017 . . RACKING DETAILS , i , , „ 1 , _ _, , „ , , 1 0 a tt ARIES t I `/ SIDE VIEW, FLUSH MOUNT ON PITCHED ROOF / O scale:1”=1'-0” I . 1 © 11 0 0 ‘s i AS REQLIRED BY I MODULE MANUFACTURE i1 I © O PV MODULE IRONRIDGE RAIL . . . ._ .. .._:_.e_. 1- MIIIMMINIW p 0 PLAN VIEW, FLUSH MOUNT ON PITCHED ROOF C FRONT VIEW, FLUSH MOUNT ON PITCHED ROOF Scale:1"=1'-0" scale:1"=1,0" PV MODULE, BY OTHERS IRONRIDGE IRONRIDGE RAIL RAIL ��; IRONRIDGE IG MID CLAMP PV MODULE FRAME PV MODULE FRAME IRONRIDGE END CLAMP --41111111..._ J� , (E) ROOF I ! ; IRONRIDGE IG MID CLAMP # PV MODULE FRAME IRONRIDGE END CLAMP PV MODULE FRAME MEMBRANE +�i�_� 0.250 1 = IRONRIDGE RAIL w `; s. IRONRIDGE RAIL IRONRIDGE f 0 . a FLASHFOOT _ _ ASSEMBLY "�" (E) BUILDING i ' I 1 STRUCTURE O STANDOFF DETAIL s DETAIL, MID CLAMP PLAN O DETAIL, MID CLAMP FRONT O DETAIL, END CLAMP PLAN O DETAIL, END CLAMP FRONT D Scale:3"=1'-0s 0 X 3 LAG SCREW E scale:6"=1,0" scale:6"=1'-0" scale:6"=1'-0" Scale.6"=1'-0" DESIGNED BY: C. BOYCE ELEMENTAL ENERGY TOM PETERSON RACKING REV:A CHECKED BY: J. GRIESER OR CCB#: 195141 11150 SW NOVARE PLACE, TIGARD, OR 97223 DETAILS PV-03 12/5/2017 LINE DIAGRAM: VOLTAGE DROP CALCULATIONS 120/240 VAC DC:22 MODULES TO INVERTER(75'MAX): SINGLE PHASE SERVICE I 2 x 75'x 9.38A x(1.290/1000 ft.)/359.39V=0.51% PGE AC: INVERTER TO INTERCONNECTION(5'MAX): < CD METER#:--- ( 2 x 5'x 25A x(.8090/1000 ft.)/240V=0.21% UTILITY \4 Main Lug GRID I EXISTING LABEL VALUES: STRING OF 22 MODS C200A MAIN p BREAKER RATED MAX POWER CURRENT 9.38 AMPS Rapid Shutdown Device RATED MAX POWER VOLTAGE 363.55 VOLTS EXISTING 30A PV BREAKER AT < 200A MAIN o BOTTOM OF BUSBAR MAXIMUM SYSTEM VOLTAGE 446.73 VOLTS FACILITY PANEL SMA AMERICA 3 SUNNY BOY 6.0-US (240V) (N)SOLADECK SHORT CIRCUIT CURRENT 9.93 AMPS LOADS JUNCTION BOX 3 6000 WATT INVERTER JUNCTION BOX ��/,� OR EQUIVALENT PV MODULES �� 1 ,/ SILFAB: SLA 310M -o o-- 100A BREAKER ° s - �° � � ..f ° +�ff (11)MODULES 15A FUSES (2)STRING OF(11)MODULES FUSED STRING COMBINER& 20A BREAKER ON EACH _ ° °- 80A BREAKER LOAD RATED DC DISCONNECT BRANCH. NO BREAKERS ON For EV Charger WITH SECURE POWER SUPPLY INSTALLS W/ <17 MODULES. CONDUIT SCHEDULE LABELING REQUIREMENTS: WARNING:PHOTOVOLTAIC # CONDUIT CONDUCTOR NEUTRAL EGC POWER SOURCE -1 NONE (2) 10 AWG PV WIRE NONE #6 LOCATED AT UTILITY METER OUTSIDE&INSIDE PANEL CODE SECTION: NEC 690.64.B.4 2 NONE (2) 10 AWG PV WIRE NONE #6 PHOTOVOLTAIC AC DISCONNECT MAXIMUMAC OPERATING CURRENT: 3 3/4"EMT OR EQUIV. IF EXT; (2) 10 AWG:THHN/THWN-2 IN (1) 10 AWG:THHN/THWN-2 IN #6 NOMINAL OPERATING AC VOLTAGE. NONE IF INTERIOR CONDUIT OR NM-B IF NO CONDUIT CONDUIT OR NM-B IF NO CONDUIT LOCATION:ON AC DISCONNECT(IF INSTALLED,WHEN AC INVERTER OUTPUT IS GREATER THAN 30A PER UTILITY NET METERING REQUIREMENT AND CODE). CODE SECTION: NEC 690.14.C.2&NEC 690.54 NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MOM POINT OF INTERCONNECTION: MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS MAXIMUM AC POWER BACKFED BREAKER ON SUBPANEL MAXmWM AC CURRENT y 1. ADD 30 AMP PV BREAKER TO MAIN PANEL SILFAB:SLA 310M 310 W NOMINAL OPERATING AC VOLTAGE 240 V MAX OVERCURRENTCEVICERATING FOR AC MODULE PROTECTION:. 2. PV BREAKER MANUFACTURER: EATON OPEN CIRCUIT VOLTAGE 40.25 V 3. SUBPANEL MANUFACTURER:---- SECTION: OPERATING AC FREQUENCY 60 HZ LOCATION:AT POINT OF INTERCONNECTION CODE OPEN CIRCUIT VOLTAGE: 690.7 44.0 V SECTION:NEC 690.53 4. SUBPANEL RATING:----A ( ) MAXIMUM AC POWER 6000 W 5. SUBPANEL MAIN BREAKER RATING:---- MAX POWER VOLTAGE 33.05 V SOLAR ELECTRIC SYSTEM 6. MAIN PANEL MANUFACTURER: BRYANT MAXIMUM AC CURRENT 25.00 A DISCONNECT LOCATED IN MAIN 7. MAIN PANEL RATING:200 A SHORT CIRCUIT CURRENT 9.93 A MAXIMUM OVERCURRENT DEVICE SERVICE PANEL. 8. MAIN BREAKER RATING:200 A SHORT CIRCUIT CURRENT(690.8(A)(1)) 12.41 A RATING FOR AC MODULE PROTECTION 30 A LOCATION: NEAR UTILITY METER,ON UTILITY METER OR SOLAR PRODUCTION METER ELECTRICAL NOTES: NOTES TO INSTALLER: '� , t � 1. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. 2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. EA ^ .» „ -4.. ,.. - 3. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LOCATION:NEXT TO SOLAR BREAKER INSIDE 4. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. ELECTRIC PANEL 5. ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 9.93 AMPS MODULE SHORT CIRCUIT CURRENT. 15.49 AMPS DERATED SHORT CIRCUIT CIRCUIT(690.8(a)&690.8(b)). DESIGNED BY: C. ROYCE E.,i,„') ELEMENTAL ENERGY CHECKED BY: J. GRIESER ELEMENTAL ENERGY TOM PETERSONSINGLE LI x OR CCB#: 195141 11150 SW NOVARE PLACE, TIGARD, OR 97223 DIAGRAM NE PV-04 12/5/2017