Plans (132)
. .. .. •.• • . .. .. ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES '00 A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED AC ALTERNATING CURRENT POWER—CONDITIONING INVERTER. • ••• •• BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. • •• • • : •• • '• • CONC • •CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY • • ' • ' .• ... ... . ... . DC DIRECT CURRENT SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH Approved plans , EGC EQUIPMENT GROUNDING CONDUCTOR ART. 110.3. V F (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING i l � ; shall be on job site. _ `,, ,:, �t.. "`, •• •• EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, • • FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE ,p;e itv Ti ru and Its ••• •• ' GALV GALVANIZED HAZARDS PER ART. 690.17. . P, S shad not be ilt� in,lGS. W GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE s-on kb e r iscre 3anC9es —A ;; � , '4 s k r GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I�?'t� y' "' °r erein �r • i„ 7.-,,,-,Z I,' F�''/= I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY Imp CURRENT AT MAX POWER WITH ART. 250.97, 250.92(B). lsc SHORT CIRCUIT kVA KILOVOLT AMPERE CURRENT 7. DC OR ARE CONDUCTORS R NU IN METALLIC EITHER METALLC RACEWAYSEORER BUILDING COPY' kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). CITY OF TIGARD MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN REVIE D FOR CODE COMPLIANCE (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. Approved: NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OTC: [ OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING Permit #: rrcc—t-r I A -000 3O P01 POINT OF INTERCONNECTION HARDWARE. Address. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE x, 77 A�.!-�P rG► i n e -�-ev'r SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. Suite#: S STAINLESS STEEL STC STANDARD TESTING CONDITIONS By: Date: _ _ � TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT � Sheet 1 COVER SHEET Sheet 2 SITE PLAN , 210 Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS � � � �` Sheet THREE LINE DIAGRAM LICENSE GENERAL NOTES � , � Cutsheets Attached OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC AND 2012 IBC. RGC, CGC1 -. 77 2. ALL ELECTRICAL WORK SHALL COMPLY WITH i h Center of Or g 01 THE CURRENT NATIONAL ELECTRIC CODE AS ���. :: AMENDED BY THE OREGON ELECTRICAL SPECIALTY (:::::) CODE. :; �. -� MODULE GROUNDING METHOD: ZEP SOLAR REV BY DATE COMMENTS AHJ: Tigard 1 MIA 11221 DATE COMMENTS UTILITY: Portland General Electric , ©©© CONFIDENTIALRWNW J g-971 14 41 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINEDSHALL NOT BEUSED FOR HEREIN JOB OME RAGHUNATH NIMMAGADDA 4.88 KW PV ARRAY Cody Anderson _ BENEFlT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: T 5 L n HALL IT BE DISIILOSED IN WHOLE OR IN CompMount Type C 13277 SW AUBERGINE TERRACE PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: SHERWOOD OR 97140 THETSALE AND USE OF INON, EXCEPT CONNECTION RESPECTIVNTH (16) TRINA SOLAR # TSM-305DDO5A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV DATE: PERMISSION OF TESLA INC. Delta ; Solivia 5.2 TL COVER SHEET 1 1/3/2018 PITOHyff& ; ARRAY;PF-CHr3$-• MP1 AZkel;TH /70i. TRAY A2I14TH:2;0: MAT£RtAL•Comp Shingle 51'ORY: 2.9tories PITCH: 38 ARRAY PITCH:38 MP2 AZIMl1TH: 1$O ARRAY•AZIMUJH: 1$O MATERIAL:t1mp SflinZle .• Sltr:2.Stories • • • • • • • •• • • • •• • • • • • •• ... ... •• ••• • ..•. ..• •• • .• .. • • ID � © . • • • •• .•. ••. .. •• • • •• .._ , , w I 1 ``_, i ----I --- U) D C Cr (E) DRIVEWAY CD 5. `°—I LEGEND ,R ,► P�c�n I rn O (E) UTILITY METER & WARNING LABEL 2 0 ® INVERTER W/ INTEGRATED DC DISCO 0 -v a�a 14P2 i & WARNING LABELS ,► ® --0 0 A DC DISCONNECT & WARNING LABELS Front Of House � 0 RSD u - � AC DISCONNECT & WARNING LABELS ' o o 0 o c 0 DC JUNCTION/COMBINER BOX & LABELS D 0 o ® o o 0 DISTRIBUTION PANEL & LABELS o 0 0 0 0 0 Lc LOAD CENTER & WARNING LABELS ® ® • O DEDICATED PV SYSTEM METER liil Rso RAPID SHUTDOWN O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r,_1 It 'I INTERIOR EQUIPMENT IS DASHED L-'J SITE PLAN N TOTAL ARRAY AREA (SF): 288 TOTAL ROOF AREA (SF): 1811 Scale: 1/8" = 1' w ® E TOTAL ARRAY AREA IS a 15.89 0 1' 8' 16' • PERCENT OF TOTAL ROOF AREA ■� s _ CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER JB-9711441 00 CUSTOMER: DESCRIPTION: DESIGN: - T 5 L n CONTAINED SHALL NOT BE USED FOR THE RAGHUNATH NIMMAGADDA 4.88 KW PV ARRAY Cody Anderson BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 13277 SW AUBERGINE TERRACE PART TO OTHERS OUTSIDE THE RECIPIENTS MODULESHERWOOD, OR 97140 ORGANIZATION, EXCEPT IN CONNECTION VAIN THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-305DDO5A.18(II) SHEET: REV DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: PERMISSION OF TESLA INC. Delta # Solivia 5.2 TL SITE PLAN 2 1/3/2018 -- -- -- - . . • . • • • •• ••• •• • • •• • •• • • • • �... .. • • ,,dk. j • (E) 2x4 �• • ( ) 2x4. • • • •• ii 40" I . . Si* S • . .. . . • • . . • • • ® • • ® • • • • • .•• ••• •. ••• • .. • • • • , , )04 c''' ............... ,I /2" (E) LBW PRE-MANUFACTURED TRUSS (E) LBW PRE-MANUFACTURED TRUSS STRUCTURE MEETS THE SIDE VIEW OF MP1 NTS PRESCRIPTIVE REQUIREMENTSSIDE VIEW OF MP2 NTS PRESCRIPTIVE REQUIREMENTS • OF THE OSSC SECTION 3111 OF THE OSSC SECTION 3111 MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 39" 0" STAGGERED LANDSCAPE 72" 24" 39" 0" STAGGERED PORTRAIT 48" 20" 64" 0" PORTRAIT 48" 20" 64" 0" TOP CHORD 2X4 @ 24"OC ROOF AZI 180 PITCH 38 STORIES:2 TOP CHORD 2x4 @ 24"OC ROOF AZI 270 PITCH 38 PITCH 38 STORIES:2 BOT CHORD 2x4 @24"OC ARRAY AZI 180Comp Shingle ARRAY AZI 270 PITCH 38 BOT CHORD 2x4 @24"OC Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS ANDY IS ALONG RAFTERS. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) ) SEAL PILOT HOLE WITH 2 POLYURETHANE SEALANT. ZEP COMP MOUNT C •tf0M11IPATA IIIIIi i*[, - ZEP FLASHING C I � mi morn * (3) INSERT FLASHING. (E) COMP. SHINGLE �' (4) PLACE MOUNT. (E) ROOF DECKINGfrALMI/ illia (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES - INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6 _ BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER41) STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL JERMATION HERON 10B N0"BER: J B-9 7114 41 0 0 CUSTOMER DESCRIPTION: DESIGN: CONTAINEDSHALL NOT BE FOR THE RAGHUNATH NIMMAGADDA 4.88 KW PV ARRAY Cody Anderson T _ 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 13277 SW AUBERGINE TERRACE PART TO OTHERS OUTSIDE THE RECIPIENTS MODULE ' SHERWOOD, OR 97140 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-305DDO5A.18(II) PAGE NAME: SHEET: REN DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. Delta # Solivia 5.2 TL STRUCTURAL VIEWS 3 1/3/2018 . . . . . • . .. •• • • . . • • ... •. . .. . •. . . • • • • . • • • • . •. • . •• . . ... • . . • . .• • • . .. . • • . .. . . . • . . • . •. . . . • . •. . • • • • • . • . . • . ... ... •• • . • . • ... • . 01.032318 Version#71.3 DESIGN SUMMARY Job#9711441 Design CodeASCE 7-10 Imp rtan e F c r 1 Ultimate Wind Speed V-Ult 95 mph 'f Fig 1609A postti ate + •-•)0:011:::!,•'-:.!: ' 7 Ground Snow Load pg 25.0 psf ASCE Table 7-1 MP Name MP1 MP2 oRoofing ` omnp Roof Ckrn1 .E Standoff Comp Mount Type:C Camp Mount Type C 'w .'', ,38a t. • ;, SLIRLL:PV 25.0 psf 25.0 psf MP Name MP1 MP2� a ung' 7 s2 X.Cantilever 24' 24" - Y-Cantilever NA NA X-Cantilever 20 20" _ ,, - Y-Cantilever NA NA Layout Staggered Wigger '. . _. . ..' _ a a . X and Y are maximums that are always relative to the structure framing that supports the PV. Xis across rafters and Y is along rafters. J CONFIDENTIAL– THE INFORMATION HERON JOB NUMBER: B-9 7114 41 0 0 CUSTOMER. DESCRIPTION: DESIGN: T - 5 L CONTAINED SHALL NOT BE USED FOR THE RAGHUNATH NIMMAGADDA 4.88 KW PV ARRAY Cody Anderson BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: - SHALL IT BE DISCLOSED IN WV f'HOLE OR IN Com Mount Type C 13277 SW AUBERGINE TERRACE PART TO OTHERS OUTSIDE THE RECIPIENTS MODIAESSHERWOOD, OR 97140 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-305DD05A.18(II) PAGE NAMEEQUSHEET: RN DATE PERMISSIONIPOFNTESLA INC. THE WRITTEN INVERTER: Delta # Solivia 5.2 TL UPLIFT CALCULATIONS 4 1/3/2018 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS •'. :'. :L1CS SI '. BOND (N) #8 GEC TO (E) UFER AT PANEL Panel Number:HOMC3OUC(200A) Inv 1: DC Ungrounded INV 1 —(1)Delta # Solivia 5.2 TL LABEL: A —(16)TRINA SOLAR # TSM-305DD05A.18((II •• • • •• • • 'Wti180491 WITH IRREVERSIBLE CRIMP Meter Number:33 891 661 Inverter;5200W, 240V, 97.5%, Zigbee, PLC PV Module;305W,279.3W PTC,40MM,BIk Frame,MC4,ZEP,1ItO ,W6t Bckkht : , CGC1;.• Underground Service Entrance INV 2 Voc: 40.2 Vpmax: 32.9 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER ••• • •• ••• •• '• ••• • • • •• • • • E 200A MAIN SERVICE PANEL Delta • ••• ••• • • •• •• • (E5 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND • • • ••• ••• • • ••• • (E) WIRING CUTLER—HAMMER4 A (� 200A/2P Disconnect n Delta Q •� •]� DC+ Solivia 5.2 TL ,� • •I •I Mr•Z: V1.1 c-Th r • (E) LOADS B .1--r • -•EGC H-•—•+•-•-•--•-a— J �, • L . . • • • • • �• I DC+ rL . ... •• • \ • �• N •�� DC- I 0 I 30A/2P GND _EGC/ __ 0� DC+ • M EV A ------,��- GEC �,,.. ,_ DC- T•� MP 1: 1x5• oB— 1 I GND I EGC _ I V (1)Conduit Kit; 3/4"EMT N J EGC/GEC -j z-z CP — T GEC _, TO 120/240V SINGLE PHASE I UTILITY SSERVICE I —L— Voc* = MAX VOC AT MIN TEMP POI (1)SQUARE D y,p H M230 PV BACKFEED BREAKER B —(1)CUTLER—HAMMER /DG221URB A —(2)Delta N Solivio Breaker; 3UA/2P, 2 Spaces Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R AC Smart RSS Rapid Shutdown, 600V, 20A, NEMA 4X, MC4 DC -(1)CUTLER—HAMMER i DGO3ONB Ground/Neutral Kit; 30A, General Duty(DG) ___ ___ (1)AWG/l0, THW61-2, Black (2)AW3#10, PV Wire, 600V, Black Voc* =223.34VDC Isc =9.72 ADC (2)AWG#10, PV Wire, 600V, Black Voc* =491.36 VDC Isc =9.72 ADC — 10 I4F—(1)AWG#10, THWN-2, Red O '4—(1)AWG;i10, TH*1-2, Green EGC Vmp =164.5 VDC Imp=9.28 ADC O L �(1)AWG#10, 1HWN-2, Green EGC Vmp =361.9 VDC Imp=9.28 ADC IL..LL(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21.6 MC (1)Conduit Kit; 3/4"EMT 6 (1 Conduit Kit; 3/4" EMT . . ,-(1)AWG#6, THWN-2, Green . EGC/GEC-(1)Conduit Kit; 3/4'.EMT. . . . . . . . . (2)AWG#10, PV Wire, 600V, Black Voc* =491.36 VDC Isc =9.72 ADC (2 AWG/10, PV VAre, 600V, Black Voc* =223.34VDC Isc =9.72 ADC I ® 4 (1)AWG/10, THWN-2, Green EGC Vmp =361.9 VDC Imp=9.28 ADC O I �(1)AWG#10, 1HWN-2, Green EGC Vmp =164.5 VDC Imp=9.28 ADC (1)Conduit Kit; 3/4"EMT 6 (1)Conduit Kit; 3/4" EMT CONFIDENTICUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHAL—L"NNOT BEE R SED FMATION HEREINTIHNUMBER:.1113 B-9711441 00 RAGHUNATH NIMMAGADDA 4.88 KW PV ARRAY Cody Anderson BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: T = 5 L in SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 13277 SW AUBERGINE TERRACE PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SHEWOOD, OR 97140 ORGANIZATION, EXCEPT IN CONNECTION WITH - THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-305DD05A.18(II) PAGE NAME: SHEET: REV DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. Delta # Solivia 5.2 TL - THREE LINE DIAGRAM 5 1/3/2018 • .. .. .. • • • . •• • . ••• .•. .•• • . •• • ••. . • .•• ..• . . • • . • • .•• . . ••• • • • . • . . . . . • • • • • • •• • • •. •SS • • . .• ••• . •• ••• • ® • • •• • • • • • • '�SoIaf�lt�/ ZepSOlar Next-Level PV Mounting Technology ^SoIaiClty Zep Solar Next Level PV IV�gLlhtiil�.TechrZplpgl.' .;. '.' •.• •.• • • .. •• Components •• •• Zep System . . for composition shingle roofs , ,,� 4 • ' .. E ,,� 3 E "�, I �r E 1 Leveling Foot � � � I ,,,, ,Az:vo-------.A*4' --,i.1-.4492,, ,,, , Part No.850-1172 MEM - Foos ETL listed to UL 467 'E .. Alt 1 1E a x l. ,� gttkrt- 4. ' Zep Bromx k : --,e,,,,,,,,„7„,:,,,,,- _,.... . Roof Attachment r€ 2'4 a�.gSkot _� �� Comp Mount . :L. Part No.850-1382 ,. ,41; Listed to UL 2582 Mounting Block Listed to UL 2703 i, -fW:4.7::., liMal OOMPgT� ti� e�F Description • PV mounting solution for composition shingle roofs t ' , • Works with all Zep Compatible Modules compt,- Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as Type 1"or"Type 2" " Interlock Ground Zep V2 DC Wire Clip 13 LISTED Part No.850-1388 Part No.850-1511 Part No.850-1448 Specifications Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift SCE 7-05 and 7-10 and snow standarload pressures to 50 psf per UL 1703 • Wind tunnel report to Ads • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 5 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind 156Driven Rain Array Skirt,Grip,End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps.zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM • •• •• •• • • • • •• • • • • • • • • • • • • • • • • •• •• • • • • • • ••• • • •• • • • • • • • • • • • *: • • • € • • •• • • • • • • Model RSS 600 4 2 Connection Diagram: I g m. • a ra • • • • 4:111tAIM 4i: E ON RAPID SHUTDOWN BOX • • • r;, P,tr € ON ROOF WITHIN 70'OF PV p a '''''-- ' 0* ,qm �. " < 0: ate■- • • i.. Ir- d''�`L' .ate EE,: nom. E, hm 3 yrs n=. - r-- .._. .a-- ,:, '�" ,_..�.`. ..._ Dc vv. BREAKER; GR AC DC vv- One conduit .t, •-:i for all wiring �� ..:.. - - �'- - # �h moi'-•- ,,,��,.. 5V SIGNAL �_ Technical Specifications ,7 , Input Ratings h5 s , -_'--<'.':',',Zi,i, Max.System vo tage. _' oSoV DG 6016 E - .Max Numberaf Input Circuit ,1 4 ". Rated Input Current Per String6A 10A Fuse Rating N/ °`' 15� , „1,„ :,,,,::_c7:1:_1%,,,,, , Ahal„Toi ,i0 Output Ratings Max.Number of Output Circu t 1 7 N Rated OutputCurrentPerClroutt — 20A I' ' \ ) / 1 Maximum Cur ent Conimtlert Conductor s 25A,, Output Terminat Wire Srze t '. I2-6 AU G :!:::::;::::-- OulputCondutt Size < ,; 1<7,:; NrA � �.�J4"(tw hetet} control Signal Method PLC Signaf 6V Signal Wil i :4 5Y Signal wire Voltage Rating hl/A _ 5V Stgnai Wire Slze Range N/A 24 General Data i Rapid vv Enclosure Size inins�osLxWaO(mm) X59Ex2 X Stf < --12244x10 x2,16316x25&`ft'85) d(�/ weight E € <.2,,,614�aEr a elba(3.Itg). for e ■f1 7 . f L °`� r� Input Connectors C-4 PV en f%i arAmphoS�APV nne tgr C-4 PV CdF}ti cfororA henO} y4 PV Coil etor` �f (` j Output Connectors MC•4 PV eons fAfnphenol H4 P Connec*8) rew Ter�sia to ,:; Operating Temperature' 4Q $Fl(±30^70°C} 4t) {t51; .'3 se Delta's Rapid Shutdown Devices provide an automatic disconnect of 600VDC Storage Temperature- -40-"185 0-85°C) _ -40-- t (•40 `8 f = residential or small commericial PV array system,fully compliant with the Rapid Humidity -s 0 -10t 4 Shutdown requirements of NEC 2014 article 690.12. It is compatible with Delta`s Max.OperatingPittuae i 1(lmabove a 20Gz_z n above, ea level single-phase residential inverters. Warranty ;10 Years = 10 Yea[ Standard Compliance EC KEY FEATURES Enclosure Protection Rating 19i�4X NF�;d� ;,;, •NEMA 4X Protection Safety `E;,, lL 1741 F k 2.2101-1 '' UL 1?4;r 1 '" •Compact and Lightweight NEC code N2014Ar0c[t0't = tEl; Artisie661 •Rack Mount Installation Delta Products Corporation, Inc. •Fast Connect with PV Connectors 46101 Fremont Blvd. •Compliant with NEC 2014 article 690.12 Fremont, CA 94538 Sales Email: Inverter.Sales@delta corp.com 6-ii hELTA •PLC Communication(Model RSS 600 1-1 only) Support Email: Inverter.Support@delta corp.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 S ® Support Hotline: +1-877-442-4832 Support(Intl.): +1-626-369-8019 C UJ6i Monday to Friday from lam to Spm PST(apart from Holidays) www.delta-americas.com I%EI. T'Il www.delta-americas.com/solarinverters •• • • • • :•. • •• •• . _ _• • . .• ss • . ••• ••• • ; • . •. • _ • • ••• •• __ • . •; ••• •• • :.. . • ss • • • ..• • . • • • •• - • • , „, ••:: . ..•• ••• • • • • • • • ..• ••• • • ••• ••• Delta Solar Inverters Datasheet for SolarCiti !.. •,..... .. .. . . • '4F-7--- ••• •• ' -. ' ' : : : : • • • • i • • ao0V • ... ••• • • •1__ g 3804 S . • • • s • e INPUT(DC) * e•• ••• • • • * ** ;'-'4,,iM 40-',,i, --;,4,,8,41i,',,',1 Jilt,,r13"''':!'„rs7,S.S''Zlhilis...-' ,.:q-'-„.,, ttli,• "i: ?4,1,_!:'7 ili.17.' 7! 85-550 V • t-11 I' 200-500 V , 2 18 0 A 00A 20,0 A per MPP tracker SoiciCitY 15 Internal 25 GA per MPP tracker 4200 W 5000 W 5600 w n 1 4 0 - 1'0'14, E 6800 W 7690 W „ M" -'8 __--' ,,,, .___, I OUTPUT(AC) 3000w 3800W 5200W / 6600,o/0208v i, 6600wo 2040 v / 5200 Wszi 208 V SOlacCitY cl- ' ' -s-7'ii, II:111 5200 iN 0240 V anxiwo 208 00 wo-240 V vo 240V - / 3000 WO 240V a 3-228 V0208 V/211-264 ,- --- - V/ 31.7 A iti 208 V 18 08 vr 31.7A6208 317 A0240 V 208V/ 24,0A 0,2 27n A0240 V ' 08 VI 15.8A@ 21,8,6,0240V 14.4A6 2 15.8 AO 240V VI 3300 WO 208 V , ,.. 4 I 12 5 AO240V 80Hz 6600 W 0 240 V 7600 wo 2 6 V I 59.3-60.5 tlz 63 0 Hz 570- i , s _ , 1 6 W - ' - -,- - <3% s 0.99 - ' '' -- -_-- %--.: 7-----17=-11 --- 0.1351—0.850 ,, ,..-; - . ,,- <000(A).::::,Int „W-t-v, v1::,:7---'------'---:':', 47114,77M -1,17r771 :---- ----,== 7 % 240V it -97'5'' 122`f(50°C) °F(.25-70tC)I deratins above _ .13-158 850 GENERAL SPECIFICATION y 0 208v981:.5 0 -40-186qF(-40*ii 0-100% 2000m above sea level MECHANICAL DESIGN 19.5x 158x 8.5 8144_ 661 461 0216 min)1 I 05.0 lbs(29.5 kg) Natural Convection 43 Ribs(.19-8102) ' ' 26.8 z 15.8 x 8.51n 080 x 401 ic 216 mm) 6 Copper)According to NEC 3101 . box AWG 12-AWG 4 . of spring terminals in song te„6nninnie inoc:cordnn4ecingatiiihrnstobNox:: 6) of 'ng terminals in connection --,p- 2 pairsAWG 12-AWG C0PPerse Ziglee Diecitst Aluminum connection box 3 LEDs,4-Line LCDP69") 0008-2-11 Salt mist NEMA 4X,IEC 8 STANDARDSUL 1741 Second Edihon, UL 1998 I DIRECTIVES 0 NEC 690.36,UL 1741 CR Solar Inverters IEEE 1547,IEEE 1547.1 Class B CSA C22.2 N0.107.1-01 FCC part 15 7.6 kW (Type I)NEC690.11 Transformerless (TL): 3.8 kW, 5.2 kW, 6.6 kW, 16996vt.. , It - RVRS$NEC ' ANSI C12.1(meet Li%AccurtiM MIMIIIIIIIIIIIMI CalSomia Rule 21,H Voltage Range: 85-550V • Wide Operating . EcO Compliant,1EEE1547 UL 1741 ORD , 600 12(with SMART 88) • Wide Operating Temperature Rang WARRANTY 10 years Range: -13- 158 F(-25-70°C) High CEC Efficiency: 97.5% Interruption) Delta Products Corpo , • Integrated AFC! (Arc Fault Circuit 46101 Fremont Blvd, Fremont,CA 94538 • NEMA 4X plus Salt Mist Corrosion Protection . support Ern.- • Natural Convection Cooling HortonSales -71-877-440-58 61 PA E Liti Support Hotline:71-877-442-4832 • Dual MPPT(5.2kW/6.6kW/7.6kVV) Support(Intl.):+1-626-369-8019 Monday to Friday from 7 am to 5 P.PST(apart from HolldaYs) 51 or 71-626-369-8021 Compact and Lightweight • UL 17 67 TA mi. 41 /IEEE 1547/IEEE 1547.1 /CEC 690.11 c US Listed/UL 1699B(Type 1)/NEC • •• •• •• • • • • •• • • • • • • • • • • • • • • : : S• • • 6 6 ° 0 • • • S.. • • • • • • • • • • • • • • • • • • • •• Mono Multi Solutions , , , _ Tr na mount FRAMED 60-CELL MODULE • • • • ,.. 1 1 ; • • • ••• • • • • •• • • • •• • • , • • • •• • • • • : • • * PRODUCTS POWER RANGE ELECTRICAL DATA(STC) • • • • • , • • • • • • • • • 1-1-IE TSM-DD05A.18(11) 280-305W • ••• ••• • ••• • v. TSM-DDOSA.15(11) 275-300W Peak Power Watts-Pm.(Wp)* 275 ; 280 285 ; 290 295 300 " 305 ..., Power OutPU1TralerancetPO4.(M- ! -;-------------- - 0-+S _ ••• ••• 1 • •• •• Tr•Inaniount DIMENSIONS OF PV MODULE(mm/inches) 947/37 3 Maximum Power Voltage-Vvw(V) 31.4 31.7 31.8 • 32.2• 1020 • 0k.,6• •309 • -- - • -111J • • • • • .40-,„Ali, -,MaxiMuni Power currea0310,(A) , 83, „Lim 897 ,4-- 9.01•. rt, 05ti,:...1.-- : Open Circuit Voltage-V.(V) ,S.• 3,7 • It 9. 402 38.7 390 393 • 3 . . , . MODULE 1 : - - , , -• -- .., Short Circuit Current.1FF(A) 926 i 9.35- . 945 ' =9,50 "- PPP--- 9.64-;J-"j; 972 . . IE1 I 1 A Module Efficiency 1.06) A MAO 16.8 171 174 17.7 180 18.3 186 CELL,T,,,,.-1',-;;:'-'",",,T. - - - - a .1 1 ELECTRICAL.DATA(NOCT) -----IVION6CRYSTALUNE MODULE 4' AL J A Maximum Power-Pu.(Wp) 205 209 212 216. 220 223 227 -T3 - MaxiMum PowerVoltage-Vure(V) 29,2 - -;29.1 29.6 i-' 29.9 30.2 30,4 30.6 sit Maximum Power Current-1mm(A) 7.02 710 717 723 7.28 7.35 242 4.gx14 --'-:---t-t--5. 2-75305.,,, -..„'-_,',-,,,,, instalen9 Hole ,___ Open Circuit Voltage•Vor(VF - ; 36.0 1 -80,=8- ; '36.6,7"--, j36.7 36.9 --T.-------.M i' 37.3 6-04 3 -,.'-', ------2'::' MWER,aUTRUTRANG -.=:'-i-T---:-i_k,,, .;:,, ,, Short Circuit Current-Is (A) 7.48 ; 7.55 ; 7.63 7.67 7.71 7.78 7.84 - - \ tt , lie . .I MECHANICAL DATA I a: C Maximize limited space with top-end efficiency 4.44 • 40/L,_. 57 992/39.7 Solar Cells Monocrystalline 156.75 x 156.75 mM(6 inches) Back View . _ ., ..,-,,, ,, 1.••••*. •Up to 186 W/m2 power density MAXIMUM EFFICIENCY , .. * ; •Low thermal coefficients for greater energy production at high , zi cll Orler00:88-1 ---t-s--- -,_-,60 cells(6 x 101 1650 x 992 x 40 mm(65.0 x 391'it 57 inches) operating temperatures Module Dimensions '-11/0.43 Weight"" ' - ' '10.6'4(42:1 lb) ,:- 5\11, ----- -, r- - .... I arninate Glass 3.2 mm(P13 inches),High Transmission,AR Coated Tempered Glass menommerd . ,,,,c04P4b, ' - '' Highly reliable due to stringent quality control - . , e ig..1.%'4; '----Backsheet ----I-7'' 1 *11910365 Aillgin -,--"orriVe:-INDWilICIU-R,61,11:6;:::------,,----, . . ti _,, _ ' maci,-- tocosA,, ii - ... . . . till, •Over 30 in-house tests(UV,TC,HF,and many more) . ' ' ' - S( I : ' - •In-house testing goes well beyond certification requirements .44opt," •PID resistant Frame Black Anodized Aluminium Alloy,Compatible with ZIP racking - - -,,----- .. Founded in 1997,Trina Solar is the world's leading •100%EL double inspection ---1 , J-Box •. -'.-_,,,f-- : IF 67 or IF,158 rated , comprehensive solutions provider for solar energy.we 1 35/1.38 believe close cooperation with our partners is critical Cables Photovoltaic Technology Cable 4.0mm2(0.006 inches), to success.Trina Solar now distributes its PV products 104')to over 60 countries all over the world.Trina Is able to connector 1200...77(47.2 inches) provide exceptional service to each customer in each - --. Certified to withstand the most challenging iv CURVES OF PV MODULE(305W) market and supplement our innovative,reliable --.--.; , MC4sie, products with the backing of Trina as a strong, = .-,ii..ri2 environmental conditions 10.0 no 1000W/O ' bankable partner.We are committed to building 71111011F- •2400 Pa wind load Fire Type UL 1703 Type 2 Mr Solar City strategic mutually hen Sc collaboration with :: wow., installers,developers,distributors and other partriers. •5400 Pa snow load g , •35 mm hail stones at 97 km/h .1 SO 4 ,,,,,,, - TEMPERATURE RATINGS MAXIMUM RATINGS U 0 .,, NOCT(Nommai Operating Cell Temperature) 44°C(±2°CI Comprehensive Products . -.. , Operational Temperature , -40-485°C And System Certificates 0 10 20 vohgem321 40 SO 'Temperature Coeffic lent of Psraa ' -03916PC -;J:- MaximumSystemVoltage .1 1000VDC(IEC IEC61215/1EC61730/UL17031EC61701/1EC62716 Temperature Coefficient of Vor -0.2916PC .---, ; ---:: 1 1000V DC(Ut1 lop% at P-V CURVES OF PV MODULE(305W) ISO 9001:Quality Management System ; 15A for 275-290W 150 14001:Environmental Management System aso Temperature Coefficient of los 0.054b1°C, -- : Max Series Fuse Rating , 20A for 295-305W 15014064:Greenhouse gases Emissions Verification 300 - OHSAS 18001:Occupation Health and Safety 250 , Management System LINEAR: PERFORMANCE WARRANTY ...;:200 . WARRANTY PACKAGING CONFIGURATION LiAii;li CC)10 i.;cns, iC lE 10 Year Product Warranty-25 Year Linear Power Warranty iw __0.Mwt„,, \`j 000 . So 10year Product Workmanship Warranty Modules per bor.30 pieces 37% 40 50 IP* V rr W[4404 ...25 year Linear Power WanantY="---'7" - -,--- Modules per 4CFc601alner 840 Pieces /§-0 4t14, ...ii P0 FE 5 I 0 ,5 20 25 CAUTION: SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ... .. TrInasolar . 1 r i n a linear'Warranty Standard Step Warranty Trinasolar .2017 Irina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Version number:TSM_EN_2017_C www.trinasolar.com t