Report (79)
SPECIFICATIONS: PKA-A18HA7 & PUY-A18NKA7(-BS) Indoor Unit PKA-A18HA7 Model Number PUY-A18NKA7 Outdoor Unit PUY-A18NKA7-BS Maximum Capacity Btu/h 18,000 Rated Capacity Btu/h 18,000 Minimum Capacity Btu/h 8,000 Maximum Power Input W 1,820 Cooling*1 Rated Power Input W 1,820 Moisture Removal Pints/h 5.2 Sensible Heat Factor 0.68 Power Factor % 95.3 SEER 18.5 Efficiency EER*1 9.9 Voltage, Phase, Frequency 208/230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 198—253 Voltage: Indoor-Outdoor, S1-S2 V AC 208/230 Electrical Voltage: Indoor-Outdoor, S2-S3 V DC 24 Voltage: Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 Fan Motor Full Load Amperage A 0.33 Fan Motor Output W 30 Airflow Rate, Dry CFM 320-370-425 Airflow Rate,Wet CFM 290-335-380 External Static Pressure in.WG n/a Indoor Unit Sound Pressure Level dB(A) 36-40-43 Drain Pipe Size In. (mm) 5/8(16) Condensate Lift Mechanism, Max. Distance In. (mm) n/a Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.0Y 9.2/0.2 W: In. (mm) 35-3/8(898) Unit Dimensions D: In. (mm) 9-13/16(249) Specifications are subject to change without notice. Copyright 0 2017 Mitsubishi Electric US,Inc. SPECIFICATIONS: PKA-A18HA7 & PUY-A18NKA7(-BS) Indoor Unit PKA-A18HA7 Model Number PUY-A18NKA7 Outdoor Unit PUY-A18NKA7-BS H: In. (mm) 11-5/8 (295) W: In. 39-6/16 Package Dimensions D: In. 15-12/16 H: In. 13-6/16 Unit Weight Lbs. (kg) 29(13) Package Weight Lbs. 33 Indoor Unit Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB, 73 WB/66 DB, 59 WB Operating Temperature range MCA A 11 MOCP A 28 Fan Motor Full Load Amperage A 0.50 Fan Motor Output W 46 Airflow Rate CFM 1,590 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type Cross fin Sound Pressure Level, Cooling*1 dB(A) 44 Sound Pressure Level, Heating*2 dB(A) 46 Compressor Type INVERTER-driven twin rotary Compressor Model SNB130FNCM2 Outdoor Unit Compressor Rated Load Amps A 7 Compressor Locked Rotor Amps A 12 Compressor Oil Type//Charge oz. FV5OS// 16 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W: In. (mm) 31-13/16+7/16(809+62) Unit Dimensions D: In. (mm) 11-3/16(300) H: In. (mm) 24-13/16(630) W: In. 37-1/16 Package Dimensions D: In. 16-3/16 H: In. 27-7/16 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. SPECIFICATIONS: PKA-A18HA7 & PUY-A18NKA7(-BS) Indoor Unit PKA-A18HA7 Model Number PUY-A18NKA7 Outdoor Unit PUY-A18NKA7-BS Unit Weight Lbs. (kg) 99(44) Package Weight Lbs. (kg) 110(50) Outdoor Unit Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/-20*DB Operating Temperature Range Refrigerant Type R410A Charge Lbs, oz 4 lbs, 14 oz Gas Pipe Size O.D. (Flared) In.(mm) 1/2 (12.7) Liquid Pipe Size O.D. (Flared) In.(mm) 1/4(6.35) Piping Maximum Piping Length Ft. (m) 165(50) Maximum Height Difference Ft. (m) 100(30) Maximum Number of Bends 15 AHRI Rated Conditions(Rated *1 Cooling (Indoor//Outdoor) °F 80°F DB, 67°F WB//95°F DB, 75°F WB - data is determined at a fixed compressor speed) Notes *Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -20°F- 115°F. Refer to wind baffle documentation for further information. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures SEACOAST PROTECTION • External Outer Panel: Phosphate coating +Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly;Valve Bed: Epoxy resin coating (at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes: Specifications are subject to change without notice. Copyright 02017 Mitsubishi Electric US,Inc. ACCESSORIES: PKA-A18HA7 3-Pole Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box] ❑ TAZ-MS303 Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑ DPLS2 MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/Reservoir&Sensor(110V) ❑ X87-711 - 110 up to 48,000 Btu/h [recommended] MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/Reservoir&Sensor ❑ X87-721 -208/230 (208/230V)up to 48,000 Btu/h [recommended] MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V) ❑ XA5-003 Fascia Kit for MicroBlue Pump—mounts beneath pump ❑ T18-016 Extension Cord for Blue Diamond Pump ❑ C13-103 Sauermann Mini-Condensation pump (115V) ❑ SI30-115 Sauermann Mini-Condensation pump(230V) ❑ SI30-230 MegaBlue Blue Diamond Condensate Pump(110-230V) ❑ X87-835 Remote Sensor(extensible) ❑ PAC-SE41TS-E Connector for CN32(remote ON/OFF) ❑ PAC-SE55RA-E Connector for CN152(Back up heating) ❑ PAC-SE59RA-E External fan/Heater control relay adapter ❑ CN24RELAY KIT-CM3 Backlit,wall-mounted,wireless ❑ MHK1 Wireless Remote Controller ❑ MRCH1 Wireless Receiver ❑ MFHI Portable Central Controller ❑ MCCH1 Outside Air Sensor ❑ MOS1 Wireless adapter ❑ PAC-USWHS002-WF-1 BACnet®and Modbus Interface o PAC-UKPRC001-CN-1 Wall-mounted, Wired ❑ PAC-YT53CRAU-J Wired Remote Controller ❑ PAR-33MAA-J T STAT Interface ❑ PAC-US444CN-1 Simple remote controller ❑ PAC-YT53CRAU Wireless Remote Controller PAR-FL32MA-E Wire for Remote ON/OFF with CN32 connector o PAC-715AD Lockdown Bracket for wireless, hand-held, remote controllers ❑ RCMKPI CB Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. ACCESSORIES: PUY-A18NKA7(-BS) Air Outlet Guide o PAC-SJO7SG-E Front Wind Baffle 8 WB-PA4 Side Advanced Wind Baffle o WB-SD4 Rear Advanced Wind Baffle o WB-RE4 Hail Guard ❑ HG-A5 Drain Socket o PAC-SJO8DS-E Centralized Drain Pan ❑ PAC-SG63DP-E Control/Service Tool ❑ PAC-SK52ST Wall Mounting Bracket(Powder-coated Steel) o QCWB2000M-1 Wall Mounting Bracket(316 Series Stainless Steel) o QSWBSS M-NET Control Adapter for Building Management System ❑ PAC-SJI9MA-E Outdoor Unit Mounting Pad 16"x 36"x 3" ❑ ULTRILITE1 Outdoor Unit 3-1/4 inch Mounting Base-Pair(Plastic) o DSD-400N MiniSplit Mounting Stand-Single Fan Models- 12" o QSMS1201 M MiniSplit Mounting Stand-Single Fan Models- 18" o QSMS1801 M MiniSplit Mounting Stand-Single Fan Models-24" o QSMS2401 M 1/4 x 1/2 x 15'/1/2" Lineset(Twin-Tube Insulation) o MLS141212T-15 1/4 x 1/2 x 30'/ 1/2"Lineset(Twin-Tube Insulation) ily MLS141212T-30 1/4 x 1/2 x 50'/1/2" Lineset(Twin-Tube Insulation) I MLS141212T-50 1/4 x 1/2 x 65'/1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-65 1/4 x 1/2 x 100'/ 1/2"Lineset(Twin-Tube Insulation) ❑ MLS141212T-100 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. DIMENSIONS: PKA-A18HA7 & PUY A18NKA7 (-BS) PKA-A18HA7 Unit:inch(mm) --- ,531— Tap side Il♦1Uiiiil iii)11 'll 239118(699) Front Side /6216.4 111 _--- I/1II. + I' A x111111 _ i 11\\4neiEe El 27.73:889 ENINE 513116(209) , 3145) \IN.oume ("`51 br ee*ire 3s va .460. ro/66660de Sleeve br1gM 0069 (purchased 164341 m'°49"m° 1 - [ 1 'i 1 t J q 62.12431119 52.1463-1A ia'. .. 46,04 (065-1160) iiiiiiih Terminal block emda �i m g9m 1 — ii q tii\I m Drag 1563 -,].,Sn9µ5Y)Gae pipe 9.5)5(189) 1 Eme,pe Ymeretlm»eU 213118(539lbuM Alpe .0-046(150) pheamel -73/14184) Under...ofa/1e 096655T910m0 BY mm. 24-1/14812) -mtlonW.. S MIIIIMIIMIIMMMIMII.... .........Lail II Fpvn 9uQDiapipe vaF($,6.35) I� Rgng Gae pipe 12F($62.7) 77 I1�i�l wewe Mane w�rZl�- '� Drain(0963 (57610.0 `./ �� ERective 13/1980 153K(/80) C Kr lo6er 9 Pewees - Mbuarppmp B Centermeasuremeni hole, 2.0 445118(49) Bol hob a 8 •.m . LIa as hr' , •�• Bak s L^g 4aoa060416 ne %'A3'."") Fi.: a I 6 o N s - A:11-"P: ... r r o Z wr■r3 .e„8�D -�,visom �l aIf �`r�_ rani 13,14218) 11118(]85) ��Ls= ra::�E c _I 2-,ns,53.5) 3611'81 4 E751 — ;ai z9/1B�sel lig),ea) pp i•i,mi 1 nog=Im!5(126.51 7117e.�1 �i= .�.iCC�O 4,53liall .61 9-15/18(2595)>•�6�\ .� ,=�, 9/1/14231.51 ��i iiii�i�iiiimiiitiial$y' X44427921 Ltit,_� `df I. irl=a frrM...w pimp"�( ' $6 FR! INwk0Rhole16rp4e,9 —il\ Required Bpacenndsor min riii ! I dilMil, ,1 1 33 7/14125)I� — .—. 0 '� 54$ :: r!' .r .i E = E 16(1.131132(501 eea8w a g II 6666-5/8 iiiii 1465-741150) '7'4 d 11 laairY (22o, i Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. DIMENSIONS: PKA-A18HA7 & PUY-A18NKA7 (-BS) PUY-A18NKA7(-BS) Unit:mm<in> ,r 404.5<l5-15/16> drain hole "' Airin6ke r e42 20 Shaped notched hobs V Insfallet19 boll pith (Fandalbn 8okM10<W 3B>) $00<19-1/16> I I E, A' ( I I i '1 Air intake Air discharge J r'i� V "<1.19/32> ern m rda6onosahoJ N 23.2<15/16< 22.3<29/32> lo2 u Servos panel <W3R>) '2</8< Terminal connection for charge plug Left .Power supply wirny \I _/ _ Right...Indoor/outdoor vnrng/ �,�" �nnection for Handle fa mono x1u pipe RARE x.35(114F) 1 I `4Nw lb, r 'A 1..,a.,l a i111j Earth terminal �I l I our. 8 NI 1.I Il. h 19 Servicepanel . I III o � A. I,ill' . ill 1. ' N 2-a22.2<7:> • - — -- 1/2 cantlum holetap RARE A .t Connection 905 gas We ARE 012.7(1/1Fl 154.5<6-3/32> - S Service port 185.5<7-5/16> 310<12-7/32> n - g m 809<31-7/8> 62<2-15/32> m Free space around the outdoor unit FOUNDATION BOLTS (basic example) Please secure the unit firmly /� with 4 foundation(M10<W3/8>)bolts. ` ' (Bolts,washers and nut must g 100mm<3-15/16>or more as long as be purchased locally). no obstacle is placed on the rear and right-and-left sides Vof the unit <Foundation bolt height> Milli LJ 0115rte\ <�925 >rte\/ g ✓ ✓✓ fWP'DA' / Ei PIPING-WIRING DIRECTION Piping and wiring connection can be made from the rear direction only. 2 sides should be open in the right,left and rear side. AAILMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com tial C ERTIFc IED. Ce US AusmA FORM#PKA-A18HA7/PUY-A18NKA7(-BS)-201709 wwam„„>< < Intertek Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. PP 5-2 ) , FID 9-22 F`I' 5-23 1T,'tus® Submittal DTQP-1.0 12-15-05 The Leader in Air Management DTQP ��� �VF r . Fan Powered Terminal, Parallel Flow Direct Digital Control, Pressure Independent B 3 3/8 1 N 20 c o,� d ter- - 1/1111o 6 v4 a o Ll +�- i - „ '4& Di_ # . 'i F,/1,1 Primary Air Inlet / -`with Multipoint , ® G B Center Averaging T Sensor L W C # I IF 9 �. —_., Induced Air ,e;_ G r.....----- Inlet ` L------ --- - L 1- 1 1 1/4 E I L Left hand unit,top view shown.All dimensions are in inches. _ Right hand units are built as a mirror image. Inlets,discharge,and control enclosure are opposite of the drawing above. e Unit Size Inlet Size A B C D E F G H J K L W N Filter Size 1�1 © 6 7 7/a 2 7/8 2, 6 7 7/s 2 7/8 7 g 7/s 4 7/8 12 8 9 a 11 7/3 4 7/ 8 6 8 /18 16 /4 7 7/ 14 1/2 14 3 1/2 17 1/8 11 2 1/8 40 7/8 361/8 2 7/B 19 x 17 8 4 10 7 9 7/8 4 7/8 a 12 8 11 7/8 4 7/8 14 10 13 7/8 6 7/8 10 7 9 7/8 4 7/8 5 12 8 11 7/8 4 7/8 14 10 137/8 67/8 16 11 10 1/18 241/2 15 7/8 17 1/2 16 1/2 91/2 20 1/8 141/2 31/8 46 7/8 48 1/8 6 7/8 27 x 20 12 8 11 7/8 4 7/8 6 14 10 13 7/8 6 7/8 16 11 15 7/8 6 7/8 Motor Amperage Ratings Accessories (Optional) Unit Motor 120/1/60 208/240/1/60 277/1/60 Check[r if provided. Size hp FLA FLA FLA X Induced Air Filter, 1"thick,disposable 2 1/6 3.6 1.5 1.3 construction type. 3 1/4 5.8 2.6 2.2 ElFan disconnect switch(not available on 4 1/3 7.8 3.2 2.9 units with optional electric coils.) 5 1/3 9.2 3.3 3.2 Fibre Free Liner 6 3/4 12.3 6.3 5.4 ❑ SteriLoc Liner FLA=Full Load Amperage,as tested in accordance with UL 1995 Hanger Brackets All fan motors are single phase, same voltage as electric coil(when 0 Cam Latch for Access Door supplied), with exception that 277 V motors are used with 480V, 3 ❑ Fan unit fusing phase coils(4 wire wye). ❑ DTQP-2.0 12-15-05 Accessories (Optional) 0 Hot Water Coil Section • 1/2"copper tubes 1 0 " 0• , O ITo °• Aluminum ripple fins,10 per inch ° • Connections:Male solder,5/8"for both 1-row and 2-row.Right hand • 171-11-111/ iii\\ 1 connections only on left hand units. • 014 • HI i1 II Left hand only on right hand units. • JL w • Galvanized steel casing • Flanged duct connection. • Coil is installed at induced air inlet. ❑ 1Row t r I ' 1 I- Ti.' -I i f ❑2Row o I R • L • . 'I__J l 1"TYPE - 47'7L.'-- • • - - S —M 9 Unit Size M(1 row) M(2 row) R S 2,3,4 1 1 '/a 17 15 5,6 1 1 '/a 25 17'/2 R and S are inside dimensions. Electric Coil Section 0 kJpuundI�.,R l+ulluuneu ciet,uic nester 0 Vpuonai Lynergy c,ontroirea tiectrlc heater Standard Features • Single side access to low voltage, 31 high voltage,and electric heater controls. • Automatic reset thermal cutouts,one '' per element ° ° ° 0 o O • Single point electrical connection for • it ��1- • • f entire unit • nr 1r fir\\ Heater Rack • Positive pressure flow switch Hi ii i /I cress Cover • Flanged duct connection •._u_JL • . • Coil is installed at discharge of unit. • Transformer tions -' Fuse Block t 1 I I �;s, 1"ryp. Disconnect switch,door r1 -� -� rIIIinTnhI interlock type • R ElManuai reset cutout ❑ Dust tight construction L_______J_• •L__I 0 Mercury contactors t • t �.� Supply Voltage 3 El 208V,1 ph,60Hz s r elm _ 1 ❑277V, I ph,00Hz 277V, 1 ph,60Hz Unit Size U R S T 2,3,4 3 1/2 14 11 2 1/8 5,6 9'/2 16'/2 14'/2 3'/8 I R and S are inside dimensions. 3 kw, 2 stage heat DTQP-3.0 12-15-05 General Description • Heavy steel casing,with leak • Adjustable SCR fan speed control • Pressure independent primary resistant construction. with minimum voltage stop. flow control. • Dual density insulation,coated to • Bottom access panels can be • Single point electrical prevent air erosion,meet removed for service. connections. requirements of NFPA 90A and • Multipoint,center averaging • Rectangular discharge opening is UL 181. velocity sensor. • Energy efficient fan motor, designed for flanged duct Primary air flow balancing connections. permanent split capacitor type, connections. mounted in vibration isolators. This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus reserves the right to make changes without written notice. AI rights reserved.No part of this work may be reproduced or transmitted in any form or by any means,electronic or mecharoceA inducting photocopy rg and recording,or B by any information stamps retrieval system udthaut permission in wnNip horn Tanklns Industrba,Inc. b , TERMINAL UNIT WEIGHTS Titus The Le.4. m Ak M:uta,+nnw+t TQS Size 20 g-. : - - Box w/ Pneumatic w/DDC or w/Electric Heat w/1 Row Coil w/2 Row Coil • trols Analog 2 145 +4 +g +25 +9 +12 3 150 +4 +9 +25 +9 +12 4 155 +4 +9 +25 +9 +12 5 220 +4 +9 +30 +17 +4 +g +30 +12 +17 230 +4 +g +30 +12 +1 TQP Size 20 ga. Base Box w/ Pneumatic w/DDC or w/Electric Heat w/1 Row Coil w/2 Row Coil Controls Analog 2 145 +4 +9 +25 +9 +12 -I 5u +4 my 7cO +9 +12 4 155 +4 +9 +25 +9 +12 5 220 +4 +9 +30 +12 +17 6 225 +4 +9 +30 +12 +17 Size 20 ga. Pneumatic w/DDC or w/Electric Heat w w/2 Row Coil Con ro 0 2 113 +4 - _ +10 +14 3 12 +4 +9 +23 • +14 153 +4 +9 +23 +10 - Note: Weights are approximate. Actual weight may vary based on specific options selected.