PFI2018-00018 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12018-00018
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 02/07/2018
Parcel: SEG1331
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: SEG1331, associated with address 13181 SW 72nd Ave. PGE Job M2448678. Install new XFMR to
serve signal controllers.
Owner: FEES
Description Date Amount
PFI Permit Fee 02/06/2018 $300.00
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
CHRIS JEWETT
10800 SW AVERY STREET
TUALATIN, OR 97062
PHONE: 503-672-5481
Total $300.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant
Signature: &CL
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12018-00018
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
CONTACT KEN FISHER AT 503 816 6146 OR KENNY@TIGARD-OR.GOV
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general, will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
R'ECE'IVED
City of Tigard AN 2 9 20x8
a PUBLIC WORKS —ENGINEERING A19
s
. . Public Fac tYImprovement (PFI) Permit'
`}—RING IVG
TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way) F{
TYPE 1—Franchise Utility Work
Check one: Ff Utilities ❑Sidewalk/driveway approach ❑Streetimprovernents performed by MVN, PGE
Detailed description: PGE Job M2448678 and/or utility agency.
INSTALL NEW XFMR TO SERVE SIGNAL CONTROLLERS ❑ TYPE 2-Sidewalk/Driveway/Sewer
Work performed for the purpose of.
• Sidewalk installation or repair.
• Driveway approach installation
13181 SW 72nd Avenue
Property a dress location(s): and/or repair
Tigard, OR 97223 • Salutary sewer lateral installation
t and/or main line tap
Applicant: Portland General Electric[Submitted by Amy Sweany] ElTYPE 3—Full scale Development
Work performed with Land use
Address: 10800 SW Avery Street approval which includes any of
City/state: Tualatin, OR Zip: 97062 the following:
Phone: 503-672-5481 Email: preregcoord@pgn.com • Subdivisions or Partitions
Contact name: SDPM Chris Jewett Phone: 503-672-5481
• Street widening
• Mainline installation for Sanitary
Portland General Electric Company sewer, Storm sewer, Tigard water
Contractor: p y and/or Tigard W'ater Service Area
CCB#: 103663 Expiration: 12/21/2018
Address: SUBMIT COMPLETED APPLICATION TO:
City/state: Zip: City of Tigard
P1annir�,a/E_jgin eering
Phone: Email: 13125 SW Hall Blvd.
Contact name: Phone: Tigard,OR 97223
Applications for"minor work in right-of-way"
only may be emailed to:
Engineer: NIA rQmTermitstigard-or.gov
Address:
City/state: Zip: FOR STAFF USE ONLY
(�
Photic: Email: Case No.: r rl Z01 000)J
Contact name: Application submittal fee(.007%of
Engineer's Estimate) S_ '6=D-
Estimated value of work is required(if over$5,000):$ 6,101.37 Additional fees: $
(within the public right-of-way) Application accepted:
1' Date:
Is work related to a LAND-USE DECISION? El Yes C1�No By:
If so,please specify (MLP,SDR,SUB,etc.) case#: Application reviewed:
1
By:14•C t S Vd-A- Date: �s`�.J 9
Is work related to a BUILDING PERMIT? ❑ Yes Cd No Applicant notified:
If so,please specify(BUILDING PERN11T)case#: By: Date: 1151106
I:\ENG\PermitApplications\pfi application Rev.10/16/2017
A iJ Aw2T VZ**J� w P--� 3i- .,.nt�c a 3p--
►
d �
'1�Nd AT V tR�.15 �S �90 STt2��i. 1f'T�-S-WCAt,4 MtjST gt 2 r�,►%� w�"� C.4W ext 1 AY
City ofTigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4
�>uAt( 5W)�:j
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Pernuttee"and shall provide financial assurance for work,if
required by the city pursuant to TMC 15.0=11.140.
* With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant arc different
People,the applicant must be the purchaser of record or a lessee in possession with written authorisation from the owner or an agent of the
owner. The owner(-,)must sign this application in the space provided or submit a written authorisation with this application. Franchised
Utilities are not required to obtain the owner's signature on the application
BY SIGNING BELOW,THE APPLICANTS)SHALL CERTIFY THAT:
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject
1?17012
• If the application is granted,the applicant will exercise the rights granted in accordance kvith the terms and subject to all the
conditions and limitations of the approval.
4
• All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herexvith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands die
requirements for approving or denying the application.
\--kA -S z
Applicant/authorized agent's signature Print name Dite
SIGNATURES of each owner of the subject property, if required.
Owner's signature Print natne Date
Owner's signature Print naive Date
Owner's signature Print narne Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov 503-718-2421 • Page 2 of4
OVERHEAD LEGEND
I34
7300 REMOVE FACILITIES INSTALL FACILITIES
CONSTRUCTION NOTES: OH
1. SEE THE PGE ELECTRIC SERVICE REQUIREMENTS(ESR)BOOK FOR THE FULL SET
U OF REQUIREMENTS.THE ESR BOOK CAN BE FOUND AT https:/Nvww.porflandgeneral.com
U
2. CUSTOMER IS RESPONSIBLE FOR OBTAINING ALL BUILDING AND ELECTRICAL PERMITS FOR
Q THE APPROPRIATE MUNICIPALITY.CUSTOMER IS ALSO RESPONSIBLE FOR OBATINING ALL
m�z N EASEMENTS AND TREE-TRIMMING PERMITS,AS REQUIRED.
°o
7325
MOVING TRAFFIC CONTROLLER 3. ALL TREE TRIMMING IS REQUIRED TO BE COMPLETED PRIOR TO PGE INSTALLING SERVICE.
I`SECONDARY OPEN ¢ SOURCE TO MAINLINE. REMOVE 4. CONTACT PGE SERVICE COORDINATOR IN ORDER TO
PL-1098 CAP BANK AND INSTALL NEW XFMR RECEIVE AN APPROVED METER SPOT AND CONFIRM THAT THE SERVICE WILL MEET
CREATE SECONDARY OPEN AT ALLAPPLICABLE CODE CLEARANCE REQUIREMENTS OVER GOUND,STREETS,PARKING
72 LOTS,ROOFS,DECKS AND BALCONIES,ACROSS OR BESIDE OTHER OVERHEAD
PL-1098 UTILITY WIRES,AND ADJACENT TO WINDOWS.
O 5. AFTER PASSING THE APPROPRIATE MUNICIPAL ELECTRICAL INSPECTION,CUSTOMER TO
1098 REQUEST AN INSPECTION BY PGE BY CONTACTING SERVICE COORDINATOR AT
50'-2 800-542-8818 OR 503-323-6700 IN THE PORTLAND AREA.PGE WILL NOT ENERGIZE THE
1982 SERVICE UNTIL ALL INSPECTIONS HAVE BEEN PERFORMED.
450 kvar
KVAR
143 100 T Q
PGS N
B 2 ACSR y
2-B210AL-SPUN 62P`�X
X C21-01D 7
SW VARNS T
WL1
Install:
1P 7.2 120/240 OH 10KVA NT1CB NF TRANSFORMER �m
Remove:
CAPACITOR BANK
7330
13235
7155 PGE CONSTRUCTION DRAWING
USX AS-BUILT VERIFICATION 8 NESC VIOLATIONS CORRECTED
This document accurately represents FIELD Construction
� Foreman: Date.-
in
General Foreman: Date.-
(Signature
ate.(Signature only required for field construction changes)
SDPMIENG REVIEW ASBUILT BY DESIGNER:
DATE: SCALE: ACCOUNT.' AWO: JOB NO.
12/29/2017 1 in : 33 ft 1070001 1000004545 M2448678
TITLE
CALL 811 BEFORE YOU DIG PGE
ATTENTION: CIRCUIT SIZE
THINK OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED WEST PORTLAND-72ND 11 x 17
BY THE OREGON UTILITY NOTIFICATION CENTER. ��� LOCATION
ANY DEV147TON FROM THIS DESIGN MUST SAFETY THOSE RULES ARE SET FORTH!N OAR 952-001-0010 13181 SW 72ND AVE„TIGARD, OR,97223
THROUGH 952-001-0090 YOU MAY OBTAIN COPIES OF DESCRIPTION
BE APPROVED BY THE PGE PROJECT MANAGER F I RST THE RULES BY CALLING THE OREGON UTILITY INSTALL TRANSFORMER, REROUTE SECONDARYS SHEET
NOTIFICATION CENTER ADMINISTRATION @(502-232-1987) COUNTY SECTIONS WORK WITH
TO REQUEST UTILITY LOCATES CALL THE OREGON """haft below. WASHINGTON C2101 D 1 1 OF—
UTILITY
F_UTILITY NOTIFICATION CENTER, 811 AT LEAST Call befom you dig. DESIGN BY PHONE(503)DRAWN BY
2 BUSINESS DAYS PRIOR TO EXCAVATION Chris Jewett I CHRIS JEWETT
0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED
Page 108 2011 Edition
5.5 Multi-Lane Roads
Right Lane Closure, Multi-Lane Non-Freeway Diag. 500
Diagram 500 covers work which closes the right lane of a multi-lane non-
freeway road.
If closing more than one lane on a multi-lane road, provide a minimum
tangent distance of 2L between the end of the first lane closure taper and the
beginning of the second lane closure taper.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCIVIS in caution
mode may be used.
3. When the posted speed is 40 mph or less, the RIGHT LANE CLOSED
AHEAD signs may be omitted.
4. Placement of signs in a non traversable median or other median that is
not a two-way left turn lane is required for lane closures any time there
is room for a truck to be parked on the left, out of the travel lane.
When there is no room for a truck to be parked on the left an additional
RIGHT LANE CLOSED AHEAD sign should be placed on the right side
and placement of signs in the median is optional.
5. If flagging is needed for work vehicle ingress/egress, use Flagger
Layout Detail (see Inset).
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs "Buffer"
Speed A B C Space
20 50
25 100 100 100 75
30 100
35 125
350 350 350
40 150
45 180
SO S00 500 500 210
55 250
60 285
65 700 700 700 325
70 365
Chapter 5 September 2016
2011 Edition Page 109
Right Lane Closure, Multi-Lane Non-Freeway Diag. 500
1 1 t t
• Protection Vehicle
• wnW(both Optional)
' See Chapter 4
•
fUU
'
I � I
I
t Buffer •
A Buffer
B I .—
IBE
I PREPARED L
I TO STOP �®
1-6 1 (Optional)
Flagger Layout Lia
Detail
A j
I N
B
*See Note 4 FUaHr uHe
*
CLOSED
1 1 t t AHEAD
C
ROAD
* _=- WORK
AHEAD
September 2016 Chapter 5
Page 118 2011 Edition
Lane Closure at Intersection with Flagging Diagram 620
Diagram 620 covers work within an intersection when normal traffic control
must be interrupted. Work vehicles may or may not be in the work space.
1. During flagging, traffic signals shall be turned off. Contact the road
jurisdiction for approval and assistance (see Chapter 3).
2. For multi-lane facilities, traffic approaching the intersection shall be
reduced to a single lane on each approach. See Chapter 3 for
information on flagging through intersections.
3. There should be one flagger for each approach. One flagger may
control two adjacent approaches if sight distance, low volumes on side
roads, and flagger position allows for safe operation and clear direction
to motorists. For low traffic volume intersections(fewer than 400
entering vehicles per day), one flagger may be used.
4. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should
be considered on high volume or high speed roads, or when extended
queues may be expected.
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs "Buffer"
Speed A B C Space
20 50
25 100 100 100 75
30 100
35 350 350 350 125
40 150
45 180
50 500 500 500 210
55 250
60 285
65 700 700 700 325
70 365
Chapter 5 September 2016
2011 Edition Page 119
Lane Closure at Intersection with Flagging Diagram 620
ROAD
WORK
AHEAD
LANE
(POP"* ROAD
AHEAD
1 1
BE
B
PRS
B
A y (0vmw
4BB
now
loon.� naso
WORK
�A C
Buffer
Tt
loot.
C B B A
ROAD EE
WOW
PaEr ' ,ao rt Max
A►� Ao�o To sroP �_ •
�E I�nr
ROAD
(01 TA
BE
PP.ePu�
TO STOP
B (00
LANE
1 t --- AHEADROAD
ROAD
WORK
AHEAD
September 2016 Chapter 5
Machine Mill The Sand And Seal
Paving Joints With
12" Area ror A 1-1/2" Hot Paving Grade
Exsting12„ Min Blanket Inlay Oil (pg 64-22 Or
Asphaltic -- * See Notes Below
Concrete Min "`- Equivalent)
t
jr
Road _, ;�f� �r�_,r ,f
Bose -r -�`�`--;�- -�� ,• %=` ;=�c.' ���-� ,
Non-Compressible
Backfill-Cement Slurry
(for Major Roads Or As • I I -
Asphaltic Concrete Pavement ��I I Specified) Ground
Undisturbed
Patch, 6" Thick Or. Match Ground
Existing Pavement (whichever Is
Greater) Up To The Level Of
Originol Pavement.
f
:_-TI
3 Crushed Aggregate
I IT Or Granular Pipe
Zone Backfill
I I---} Material
I -•-
Lo
- � I� -I i f ! ! I !_1 III--• i I I �
LZ
o Trench Width
w Per Plan or
h4 As Specified
*
o Notes:
Blanket Patches To Be Constructed With Level 2, 1/2 Inch, Dense, Pg-64-22
o Hmoc In Dry Pavement Conditions, Where Existing Pavement Is At Least 60' F
And Rising.
• Tack All Pavement To Be Inlaid With Emulsified Asphalt.
h The City Engineer Shall Determine the final Width and Length of the Inlay Patch
ro to Best Fit Travel Patterns.
3�
r
t0
O�
z
u�0
CAPITA.CONSTRUCTION AND
d TRANSPORTATION DIVISION
City of Tigard FIGURE
r� �1tJ/IT
� 13125 S.W. fW1OREGON
BLVD. Blanket I n l a y 1
I. . 77G.4R0, OREGON 97723
z
VOICE: 503-639-4171
FAX: 503-624-0757 Detail FILE NO
I WWW.T7a4RD-OR.GOv
n�a