Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (73)
S, C)1 0 0 f9r. "5 6A) 586( Lakeview Blvd.,Suite 100 Alarm Lake Oswego,OR 97035 (503)627-0100 CCB#135901 NONNI CORPORATION DEC 2 7 TiGIAR9 BUNTING DIVISiO) Arbor Heights Apartments 15199 SW Royalty Pkwy Tigard, OR 97224 ^ F 5863 Lakeview Blvd.,Suite 100 paw Lake Oswego,OR 97035 (503)627-0100 Mail/tar CORPORATION TABLE OF CONTENTS Equipment Specification Sheets Fire Alarm Equipment 1) Notifier NFW2-100—Fire Alarm Control Panel 3 2) Notifier FCPS-24S6—Remote Power Supply 9 3) Notifier NMM-100P—Addressable Monitor Module 11 4) Notifier NC-100—Addressable Control Module 15 5) Notifier NP-100—Addressable Photoelectric Detector 17 • DN-60602:A1 FireWarden-100-2(E) Rev 3 Intelligent Addressable FACP N07-1 Fl E R° by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3 (NFW2-100) with Version 5.0 firmware is a combination FACP(Fire Alarm Control Panel) and DACT(Digital Alarm Communicator/Transmitter)all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. , The's quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS,and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public • Remote site or local USB port upload/download, using PS- switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four (4) Style Y (Class B) NAC circuits, which can be con- load utility. In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windows@ XP or greater, a com- power when using optional XRM-24B.) patible modem, and PS-Tools--the Upload/Download software • Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, • address- walktest data, current status and system voltages. The panel able o monitor modulesdge, Silence, Reset and Dor via y ACS can also be programmed through the FACP's keypad or via a nn ormodules or FDU-80, N-ANN-80 or Legacy ACS standard PS-2 computer keyboard, which can be plugged Annunciators. directly into the printed circuit board.This permits easy typing of • ANN-BUS for connection to following optional modules(cannot address labels and other programming information. be used if ACS annunciators are used): Version 5.0 firmware supports the following: Primary and Sec- –N-ANN-80(-W)Remote LCD Annunciator ondary ANN-bus devices,NP-A100, USB port,NAC circuit diag- –N-ANN-I/O LED Driver nostics, a new report has been added to the walk-test that lists –N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone –N-ANN-RLY Relay Module type code for NFV-25/50ZST,Photo Supervisory and auto-reset- table Drill(non-latching). –N-ANN-LED Annunciator Module The FireWatch Series Internet monitoring modules IPDACT-2 –N-ANN-RLED Annunciator Module alarms only and IPDACT-2UD permit monitoring of alarm signals over the –ROME Relay Option Module Enclosure Internet saving the monthly cost of two dedicated business tele • ACS&Terminal-mode Annunciators: phone lines. Although not required, the secondary telephone –ACS Annunciators:Up to 32 Legacy ACM Series annuncia- line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term "FireWarden-100-2" –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the FireWarden-100-2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, `NFW2-100"refers to NFW2-100E as well. cuit board,for use/PC thoptional UL-listedable ed printerrate) R -6.n cir- for with PRN-6. Features • Integral 80-character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 3 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- lation is excessive. KEYPAD CONTROLS • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point (NFPA 72 compliant). • Enter NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E: Same as NFW2-100, except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NA CS): tion. • Four onboard NACs with additional NAC capability using out 4XTM Reverse Polarity Transmitter Module: Provides super- put control modules (NC-100). The four Class B NACs can vised output for local energy municipal box transmitter, alarm, be converted to four Class A NACs with optional ZNAC-92 and trouble. converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y (Class B) NAC circuits to four(4) Style Z(Class A) cir- • Continuous, March Time, Temporal or California code for cults. main circuit board NACs with two-stage capability. PS Tools: Programming software for Windows based PC • Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. • 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for Fire Warden-100-2 Rev 3. NOTE: Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi-flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75, XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB: Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram (learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120: Remote battery charging system for lead-acid batter- or selected from an internal library file. les with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable), for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than • Continuous fire protection during online programming at the 18AH. front panel. BAT Series:Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows®-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable;required for printer or for local upload/download program- able on www.magni-fire.com). Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to Male-B cable. IPDACT2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit(PN IPBRKT). User Interface Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- LED INDICATORS net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) IR.(See data sheet DN-60408 for more information.) • Fire Alarm (red) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 4 • N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). A00 N-ANN-RLED:Provides alarm(red)indicators for up to 30 input s s1 of Fo ma Cessable conttacts, which operaterelay modulenasna DPDT twoing I switch. zones or addressable points. (See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SMB500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides NMM-100-10: Ten-input monitor module. Mount one or two a connection for a serial or parallel printer.(See DN-7103.) on a CHS-6ules in a BB-XP in a BB-25.et(optional).Mount up to six modules N-ANN-I/O: LED Driver Module provides connections to a user on a chassis a supplied graphic annunciator.(See DN-7105.) NZM-100-6: Six-zone interface module for compatible conven onaACM-8R: Relay module provides 8 Form-C 5.0 amp relays. cab nl t(optional).Mount ptwo-wire detectors. ount to six modules on aone or twouCHS-6 in ales BB-XP ACM Annunciator Series: LED-type fire annunciators capable in a BB-25. of providing up to 99 software zones of annunciation. Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100-/S0(DN-6994),NP-100 series custom graphic annunciators. (DN-6995), NI-100(DN-6996),NH-100 series(DN-6997), ND-100 FDU-80(Liquid Crystal Display)point annunciator: 80 char series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ acter, backlit LCD-type fire annunciators capable of displaying NOT-BGI2LX (DN-7001),6NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(DN- 0524),LDM Series(DN-0551),FDU-80(DN-6820). While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical COMPAT/6LEADDRESSABLEDEV/CES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size NI-100:Addressable low profile ionization smoke detector. depends on the length of the SLC circuit. Refer to the panel NP-100:Addressable low-profile photoelectric smoke detector. manual for wiring details. NP-100T:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100: Fast-response,low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification DN-60602:A1•12/07/2010—Page 3 of 6 5 • FireWarden-100-2 Rev 3 Fire Alarm Control/ �'_:�: ANN-BUS Communicator ..-^. �'." or ANN BUS DEVICES EIA-485 —71 N-ANN-80,N-ANN-LED, in ACS mode ► N-ANN-S/PG,N-ANN-I/O (two wires) En �- 24 VDC .® E " - A SMOKE DETECTORS NP-100,NP-100T, 4741441, NI-100,NP-A100 I Ir .I I ► 4 Optional ► i \ J REVERSE �/ POLARITY/ HEAT DETECTORS NH-100,NH-100R,NH-100H CITY BOX OUTPUT i vl i vi l i 1 i (4 X T M) gip li ANNUNCIATORS *17®I ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS NOTE:System can use (optional,order ACM-8R) DUCT DETECTORS either ANN-BUS devices ND-100,ND-100R,DNR OR ACS-mode annunciators. They cannot be used ono o simultaneously. NACs(Notification Appliance Circuits) ► BELLS,SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-100R INTERFACE (PIM-24)built into the motherboard 0 h i l i 11111�—� ®_88oa_ �� ► r--- ADDRESSABLE ULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They ij[00 cannot be used simultaneously. IT EIA-485 INTERFACE 24 VDC ►(four wires) MINI-MONITOR •.•.. NMM-100P •,, 4, • FIRE 3 FDU-80 ` ' Up to 6,000 ft.(1825.8 m) I- �� between each FDU-80 in o the EIA-485 loop,and between PULL STATION each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 6 Y DN-60602:A1•12/07/2010—Page 5 of 6 7 1 , I , SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.) deep. Trim Ring(TR-CE- • Intelligent Signalling Line Circuits 1 B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Addressable device capacity 198 • Programmable software zones 99 Shipping Specifications • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • ANN-bus devices 16 high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Electrical Specifications Temperature and Humidity Ranges AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 This system meets NFPA requirements for operation at 0 — amps. FireWarden-100-2 Rev 3(E):240 VAC, 5 0 Hz, 1.5 amps. 49 C/32—120°F and at a relative humidity 93%±2%RH(non- Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. licondensing) at 32°C ±2°C (90°F± 3°F). However, the useful and e electronic compo- Battery charger capacity:7 AH-18 AH batteries. Up to two 18 nents may be e of the system's dversely affecbted atteries by extreme temperature ranges Ah batteries can be housed in the FACP cabinet. Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120,and a separate battery cabinet such as the BB-26 or temperature of 15—27°C/60—80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y(Class B) for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B) or with an optional ZNAC-92 module converts to four Style Z(Class A) NACs. Maximum signaling current per circuit: —LOCAL (Automatic, Manual, Waterflow and Sprinkler 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 Supervisory). UL listed)for Style Y(Class B)NAC. Refer to panel documenta- —AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notifier Device Compatibility Document for listed corn- 4XTM). patible devices. —REMOTE STATION (Automatic, Manual, Waterflow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps @ 30 VDC(resistive), 0.5 amps @ 30 alarm,trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of VAC(resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- alarm and trouble,4XTM is required.) nal):Jumper selectable(JP4)for conversion to resettable power —PROPRIETARY (Automatic, Manual, Waterflow and Sprin- output. Up to 1.0 amp total DC current available from each out- kler Supervisory). put.Power-limited. —CENTRAL STATION (Automatic, Manual, Waterflow and Special Application Resettable Power (24 VDC nominal): Sprinkler Supervisory). Jumper selectable(JP6)for conversion to non-resettable power. —OT, PSDN(Other Technologies, Packet switched Data Net Up to 1.0 amp total DC current available. Refer to the Notifier work) Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel. In some cases,certain modules may to NAC 1 control.Supervised and power-limited. es, or Telephone Interface: Unless used with Teldat VISORALARM, pro cesst be .sConsted sult factory latestfor y certain plistingroval lstatuslisting may be in requires dedicated business telephone number with a minimum •of 5 volts DC (off-hook voltage). Obtain dedicated phone line UL Listed:S635 directly from your local phone company. Do not use shared • FM approved phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E, Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®is a registered trademark of and ExcederTM is a trademark of Cooper Notification. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. -x C E R-r F 1 E D We cannot cover all specific applications or anticipate all requirements. 4R�k�+� 61pNEBINiShWIM#CTINN6 All specifications are subject to change without notice. ��� QUALITY SYSTEMS ��.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.corn Page 6 of 6—DN-60602:A1•12/07/2010 8 DN-6927:A2 FCPS-24S6(C/E) & FCPS- 24S8(C/E) NOTIFIER 6- & 8-Amp 24-Volt by Honeywell Remote Power Su• •lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries.The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B(Style Y)or Class A(Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, • Includes integral battery charger capable of charging up to Wheelock,or Gentex"Commander2"appliances. 18 AH batteries.Cabinet capable of housing 7.0 AH batter- • Operates as a "sync-follower" or as a "sync-generator" ies. (default). See note on page 2. • Battery charger may be disabled via DIP switch for applica- • Contains two fully-isolated input/control circuits - triggered tions requiring larger batteries. from FACP NAC (NAC expander mode) or jumped perma- • Fixed, clamp-type terminal blocks accommodate up to 12 nently"ON"(stand-alone mode). AWG(3.1 mm2)wire. • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module)NACs. Specifications • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- Primary(AC)Power: put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. output in stand-alone mode(UL 1481). • Wire Size: minimum#14 AWG(2.0mm2)with 600 V insula- • Compatible with coded inputs;signals passed through. tion. • Optional power-supervision relay(EOLR-1). Control Input Circuit: • In stand-alone mode, output power circuits may be config- • Trigger Input Voltage: 9 to 32 VDC. ured as: resettable, (reset line from FACP required), • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 non-resettable,or a mix of two and two. -16 V). • Fully regulated and filtered power output-optimal for pow- Trouble Contact Rating: 5 A at 24 VDC. ering four-wire smoke detectors, annunciators, and other Auxiliary Power Output: Specific application power 500 mA system peripherals requiring regulated/filtered power. • Power-limiting technology meets UL power-limiting require- maximum. ments. Output Circuits: • Form-C normally-closed trouble relay. • +24 VDC filtered, regulated. • Fully supervised power supply,battery,and NACs. • 3.0 A maximum for any one circuit. • Selectable earth fault detection. • Total continuous current for all outputs(stand-alone mode): • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S6: 4.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- —FCPS-24S8: 6.0 A maximum. lizes an industry-standard reverse-polarity notification cir- • Total short-term current for all outputs(NAC expander mode): cuit(including unfiltered and unregulated NAC power). • Requires input trigger voltage of 9-32 VDC. —FCPS 24S6: 6.0 A maximum. • Self-contained in compact, locking cabinet- 15"H x 14.5"W —FCPS-2458: 8.0 A maximum. Secondary Power(Battery)Charging Circuit: x 2.75"D(cm:38.1H x 36.83W x 6.985D). • Supports lead-acid batteries only. DN-6927:A2•5/17/13—Page 1 of 2 9 • , • Float-charge voltage: 27.6 VDC. Standards and Codes • Maximum current charge: 1.5 A. • Maximum battery capacity: 18 AH. The FCPS-24S6 and FCPS-24S8 comply with the following standards: Applications • NFPA 72 National Fire Alarm Code. • UL 864 for Example 1:Expand notification appliance power an additional (NAC expanderrd modeControl Units for Fire Alarm Systems 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four ).• Class B (Style Y) outputs or four Class A (Style Z) outputs UL 1481 Power Supplies for Fire Alarm Systems. (using ZNAC-4). For example,the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation Agency Listings and Approvals occurs. Trouble conditions on the FCPS are sensed by the These listings and approvals apply to the modules specified in FACP through the notification appliance circuit. this document.In some cases,certain modules or applications Example 2: Use the FCPS to expand auxiliary regulated 24- may not be listed by certain approval agencies, or listing may volt system power up to 4.0 A (FCPS-2456) or up to 6.0 A be in process.Consult factory for latest listing status. (FCPS-2458). Both resettable and non-resettable power • UL Listed: S635,S674 options are available. Resettable outputs are created by con- • ULC Listed:S635(FCPS-24S6C&FCPS 24S8C) necting the resettable output from the FACP to one or both of the FCPS inputs. • CSFM Approved: 7315-0028:225 Example 3: Use addressable control modules to activate the • MEA: 299-02-E FCPS instead of activating it through the FACP notification • FM Approved appliance circuits.This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding Ordering Information system architecture in various applications. FC VAC remocharger power supply. S6: For example, an addressable control module is used to acti- ncud s4main6.0 printed20 ciircuit board,transformers, enclosure vate the FCPS,and an addressable monitor module is used to (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985Dj),and sense FCPS trouble conditions. Local auxiliary power output installation instructions. from the FCPS provides power to the addressable control module. FCPS-24S6C: Same as above,ULC-listed. *NOTE:Addressable FACPs are capable of locating control and FCPS-24S6R: Same as FCPS 2456 with red enclosure. monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes man re inted Sync Follower/Generator Note (15"H x 14.5"W board, i[cm:38.1 H x 36.83W 6.985D]),and In some installations, it is necessary to synchronize the flash installation instructions. timing of all strobes in the system for ADA compliance. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Strobes accomplish this by monitoring very short timing pulses Includes main printed circuit board, transformers, enclosure on the NAC power which are created by the FACP. When (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installed at the end of a NAC wire run, the FCPS-24S6/-2458 installation instructions. can track (i.e. "follow") the strobe synchronization timing FCPS-24S8C Same as above, ULC-listed. pulses on the existing NAC wire run.This maintains the overall system flash timing of the additional strobes attaches to the FCPS-24S8R: Same as FCPS 2458 with red enclosure. FCPS. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure When the FCPS-24S6/-24S8 is configured(via DIP switch set- tings) as a"sync follower,"the FCPS's NAC outputs track the (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and strobe synchronization pulses present at the FCPS's sync installation instructions. input terminal.The pulses originate from an upstream FACP or ZNAC-4: Class A(Style Y)NAC option module. other power supply. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire When the FCPS-2456/-2458 are configured (via DIP switch smoke detector power. settings) as a "sync generator,"the FCPS's sync input termi- BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In Series data sheet DN 6933). "sync generator"mode,the sync type(System Sensor,Whee- lock,or Gentex)is selectable via DIP switch settings. System Sensor®and NOTIFIER®are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. IS 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. — C E R T F E R We cannot cover all specific applications or anticipate all requirements. MUM6INpNIFACi11111� All specifications are subject to change without notice. 1.............. MUM QUALITY SYSTEMS � ..... For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 2 of 2—DN-6927:A2•5/17/13 10 DN-6999:E Monitor Modules NMM-100(A), NMM-100P(A), NZM-100(A), NOT! Fl E Ro and NDM-100(A) for FireWarden Series by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- e % 4111110 tact input devices, such as conventional heat detectors and _- - pull stations, or monitor and smoke detectors NZM-100 A power a circuit of two-wire NMM-100(A)is a standard-sized modulet y ' (ypicall mounts to a 4"[10.16 cmj square box)that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. "'""" 7. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm)H x 2.75"(6.985 cm)Wx 0.65"(1.651 cm)D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. may.. �:.. -�: „� �. �. ft NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. NMM-100(A)(Type H) NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B to monitor normally-open supervisory devices with special (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol that greatly (provided) terminates the Style B circuit. No resistor is increases the speed of communication between analog intel- required for supervision of the Style D circuit. ligent devices. Intelligent devices communicate in a grouped NMM-100(A)OPERATION fashion. If one of the devices within the group has new infor- mation,the panel CPU stops the group poll and concentrates Each NMM-100(A) uses one of the available module on single points. The net effect is response speed greater addresses on an SLC loop. It responds to regular polls from than five times that of other communication protocols. the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit(IDC). A flashing NMM-100(A) Monitor Module LED indicates that the module is in communication with the conol• Built-in type identification automatically identifies this current limitations m tati ns on thel. The EDe latchesloop) steady on alarm (subject to device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional NMM-100(A)SPECIFICATIONS power required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 375 pA(LED flashing), 1 corn- • Direct-dial entry of address: 01 —99 on FireWarden-100- munication every 5 seconds,47k EOL. 2, 01 —50 on FireWarden-50. • LED flashes during normal operation and latches on Maximum IDC wiring resistance: 1500 Ohms. steady to indicate alarm. Maximum IDC Voltage: 11 Volts. The NMM-100(A)Monitor Module is intended for use in intel- EOL resistance:47K Ohms. ligent, two-wire systems, where the individual address of Temperature range:32°F to 120°F(0°C to 49°C). each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Humidity range: 10%to 93%noncondensing. Device Circuit(IDC)for normally-open-contact fire alarm and Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x supervisory devices.The module has a panel-controlled LED 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x indicator. 2.125"(5.398 cm)deep box. NMM-100(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual NMM-100P(A) Mini Monitor Module fire alarm pull stations,waterflow devices, or other normally- • Built-in type identification automatically identifies this open dry-contact alarm activation devices. May also be used device as a monitor module to the panel. DN-6999:E•07/30/2015—Page 1 of 4 11 • • Powered directly by two-wire SLC loop. No additional Wire length:6"(15.24 cm)minimum. power required. • High noise(EMF/RFI)immunity. NZM-100(A) Interface Module • Tinned,stripped leads for ease of wiring. • • Direct-dial entry of address:01—99 on FireWarden-100-2, Supports compatible two-wire smoke detectors. 01 —50 on FireWarden-50. Supervises IDC wiring and connection of external power source. • High noise(EMF/RFI)immunity. 3 1415 0 1 ADDRESS 0 1 • SEMS screws with clamping plates for ease of wiring. 13 2 12 3 1 3 • Direct-dial entry entry of address:,01—99 on FireWarden- 1110 5 LOOP 4 100-2,01 —50 on FireWarden 50. 9 $ _ 6 9 6 5 • LED flashes during normal operation. TENS 8 • LED latches steady to indicate alarm on command from ONES control panel. I The NZM-100(A) Interface Module is intended for use inintelligent, addressable systems, where the individual I I address of each module is selected using built-in rotary O 1..... 0 A U switches. This module allows intelligent panels to interface p W and monitor two-wire conventional smoke detectors. It trans- :: > m mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel.All two-wire detectors being monitored must be UL compatible with the I module. NZM-100(A) APPLICATIONS The NMM-100P(A)Mini Monitor Module can be installed in a Use the NZM-100(A) to monitor a zone of two-wire smoke single-gang junction directly behind the monitored unit. Its detectors. The monitored circuit may be wired as an NFPA small size and light weight allow it to be installed without rigid Style B (Class B) or Style D (Class A) Initiating Device Cir- mounting. The NMM-100P(A) is intended for use in intelli- cult.A 3.9 K Ohm End-of-Line Resistor(provided)terminates gent, two-wire systems where the individual address of each the end of the Style B or D (class B or A) circuit (maximum module is selected using rotary switches. It provides a two- IDC loop resistance is 25 Ohms). Install ELR across termi- wire initiating device circuit for normally-open-contact fire nals 8 and 9 for Style D application. alarm and security devices. NMM-100P(A) NMM-100P(A)APPLICATIONS NZM-100(A)OPERATION Use to monitor a single device or a zone of four-wire smoke Each NZM-100(A) uses one of the available module detectors, manual fire alarm pull stations,waterflow devices, the controesl on an SLCd reportslepo. It responds tod theular usll( pen/ or other normally-openthe control panel and its type and status (open/ dry-contact devices. May also be normal/short) of its Initiating Device Circuit (IDC). A flashing used to monitor normally-open supervisory devices with spe- LED indicates that the module is in communication with the cial supervisory indication at the control panel. Monitored cir- control panel. The LED latches steady on alarm (subject to cuit/device is wired as an NFPA Style B (Class B) Initiating current limitations on the loop). Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NZM-100(A)SPECIFICATIONS NMM-100P(A)OPERATION Nominal operating voltage: 15 to 32 VDC. Each NMM-100P(A) uses one of the available module Maximum current draw:5.1 mA(LED on). addresses on an SLC loop. It responds to regular polls from Maximum IDC wiring resistance:25 Ohms. the control panel and reports its type and the status (open/ normal/short)of its Initiating Device Circuit(IDC). Average operating current: 270 pA, 1 communication and NMM-100P(A)SPECIFICATIONS 1 LED flash every 5 seconds, 3.9k eol. Nominal operating voltage: 15 to 32 VDC. EOL resistance:3.9K Ohms. Average operating current: 350 pA, 1 communication External supply voltage (between Terminals T10 and T11): every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). • DC voltage:24 volts power limited. Maximum IDC wiring resistance: 1500 Ohms. • Ripple voltage: 0.1 Vrms maximum. • Current: 90 mA per module maximum. Maximum IDC Voltage: 11 Volts. Temperature range:32°F to 120°F(0°C to 49°C). Maximum IDC Current:450 pA. EOL resistance:47K Ohms. Humidity range: 10%to 93%noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Temperature range:32°F to 120°F(0°C to 49°C). 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Humidity range: 10%to 93%noncondensing. 2.125"(5.398 cm)deep box. Dimensions: 1.3"(3.302 cm)high x 2.75"(6.985 cm)wide x 0.65"(1.651 cm)deep. Page 2 of 4—DN-6999:E•07/30/2015 12 ITIOO(A) DualMonitorModule . csF!7300o028.0230 (NMM100NMM100PNzM T he NOM-100(A) Dual Monitor Module is intended for use in 100); 7300-0028:0237(NOM-100). intelligent, two-wire systems. It provides two independent two- • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); wire initiating device circuits(IDCs)at two separate,consecutive 227-03-E Vol.3(NDM-100). addresses.It is capable of monitoring normally open contact fire alarm and supervisory devices.The module has a single panel- Product Line Information controlled LED. NOTE: The NDM-100(A)provides two Style B(Class B) IDC cir- NOTE:"A"suffix indicates ULC-listed model.cuits ONLY. Style D(Class A) IDC circuits are NOT supported in NMM-100(A):Monitor module. any application. NMM-100P(A):Monitor module, miniature. NDM-100(A)SPECIFICATIONS NZM-100(A):Monitor module,two-wire detectors. Normal operating voltage range: 15 to 32 VDC. NDM-100(A): Monitor module, dual, two independent Class Maximum current draw:6.4 mA(LED on). B circuits. Average operating current:750 pA(LED flashing). SMB500:Optional surface-mount backbox. Maximum IDC wiring resistance: 1,500 Ohms. NOTE: See installation instructions and refer to the SLC Wiring Maximum IDC Voltage: 11 Volts. Manual,PN 52304. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. NDM-100(A)AUTOMATIC ADDRESSING The NDM-100(A)automatically assigns itself to two address- able points,starting with the original address. For example, if the NDM-100(A) is set to address"26", then it will automati- cally assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A),and NDM-100(A)modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635. • ULC:S635. • FM Approved. DN-6999:E•07/30/2015—Page 3 of 4 13 + r Notifier®and FireWarden®are registered trademarks and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF 1 E We cannot cover all specific applications or anticipate all requirements. =ME I MMIFACIIRJIYII All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.corn Page 4 of 4—DN-6999:E•07/30/2015 14 • NC-1 00(A) dn-7000:a2•Ai-360 Control Module for ® NOTIFIER® FireWarden Series Panels by Honeywell General The NC-100(A) Addressable Control Module provides NOTI- FIER's FireWarden Series intelligent control panels a super- vised Class B (Style Y) of Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the NC-100(A) to be activated, either manually or through panel programming, on a select(zone or area of coy- =" erage)basis. trtunicort4 Features • Built-in type identification automatically identifies these •ARAN MRpn devices to the control panel. • �..; .; • Internal circuitry powered directly by two-wire SLC loop. 1 The NC-100(A) module requires power(for horns, strobes, rihN 117) etc.). • Integral LED "blinks" when communicating, and turns on40 steady when activated. s • High noise immunity(EMF/RFI). � �-� �- "-� � �•, ,. :"_ • The NC-100(A) may be used to switch 24-volt NAC power. • Wide viewing angle of LED. NC-100(A) • SEMS screws with clamping plates for wiring ease. • Direct Decade entry of address: 01 —99 with FireWarden- 100-2(C),or 01-50 with the FireWarden-50(C). Specifications Applications Normal operating voltage: 15 to 32 VDC. The NC-100(A)is used to switch 24 VDC audible/visual power. Maximum SLC current draw:6.5 mA(LED on). Average operating current:350 pA(LED flashing). Construction External supply voltage:maximum 80 volts(RMS or DC). • The face plate is made of off-white heat-resistant plastic. Drain on external supply: 2 mA maximum (using internal • Controls include two rotary switches for direct-dial entry of EOL relay). address setting. • The NC-100(A) is configured for a single Class B (Style Y) EOL resistance:47K ohms. or Class A(Style Z)Notification Appliance Circuit. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%non-condensing. Operation Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Each NC-100(A) uses one of the module addresses on a SLC loop. It responds to regular polls from the control panel and 2.125"(5.398 cm)deep box. reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED Agency Listings and Approvals blinks with each poll received. On command, it activates its internal relay.The NC-100(A) supervises Class B (Style Y)or In psome cases, certain modulesmay may not be process. Consult y certain fa- Class A(Style Z)notification or control circuits. listapproval agencies, or listing be in fac Upon code command from the panel,the NC-100(A) will dis- tory for latppt• oved status. connect the supervision and connect the external power sup- FM approved ply in the proper polarity across the load device. The • UUULC Listed:file S635. disconnection of the supervision provides a positive indication • CSFM approved:file 7300-0028:230. to the panel that the control relay actually turned ON. The •external power supply is always relay-isolated from the com— munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable)will identify the module to the con- trol panel. dn-7000:a2•06/17/10—Page 1 of 2 15 • Contact Ratings Current Maximum Load Rating Voltage Description Application 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5 A 30 VDC InCoded (L/R=Sms) 1 A 30 VDC InCoded (L/R=2ms) .3 A 125 VAC Inductive (PF=0.35) Non-Coded Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded Product Line Information NC-100: Intelligent addressable control module. NC-100(A): Intelligent addressable control module, ULC listed version. SMB500:Optional surface-mount backbox. CB500: Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in the same junction box as NC-100(A). NOTE: For installation instructions, see document 156-2592-001 and refer to the SLC Wiring Manual, document 52304. The NC- 100R(A) relay module, previously on this data sheet, is now on DN-60383. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. x iiimimmap C E R T F E Q We cannot cover all specific applications or anticipate all requirements. BMW SMANNIKIN All specifications are subject to change without notice. QUALITY SYSTEMS •........, For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 2 of 2—dn-7000:a2•06/17/10 16 • NDN-6995:D•A1-320 P-100(A) Series Addressable Photoelectric N OT I F I E R® Detectors by Honeywell Addressable Devices General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs).The NP-100T(A)adds thermal sensors that will alarm rt >e at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly w locate a fire during its early stages, potentially saving preciousAVOW,' rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional " NP-100(A) in B210LP(A) Base accessory, PN RA100Z(A). The NP-100R(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detec- tor housings. Features OPTIONS • Remote LED output connection, PN RA100Z(A). SLC LOOP • Two-wire loop connection. Applications • Unit uses base for wiring. Use photoelectric detectors in life-safety applications to provide ADDRESSING a broad range of fire-sensing capability, especially where smol- dering fires are anticipated.Ionization detectors are often better • Addressable by device. than photoelectric detectors at sensing fast,flaming fires. • Rotary, decimal addressing: 01 –99 with FireWarden-100-2 and NSP-25,and 01 –50 with FireWarden-50. Construction ARCHITECTURE These detectors are constructed of off-white fire resistant plas- tic.• Unique single-source, dual-chamber design to respond NP-100(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. • Sleek,low-profile design. appearance. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. • Removable cover and insect resistant screen for sim le field NP-100(A) series plug-in detectors use a detachable mounting cleaning, p base to simplify installation,service and maintenance. Mount base(all base types)on an electrical backbox which is at OPERATION least 1.5" (3.81 cm) deep. For a chart of compatible junction • Withstands air velocities up to 4,000 feet-per-minute (20 m/ boxes,see DN-60054. sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC • Factory preset at 1.5% nominal sensitivity for panel alarm loop, end-of-line resistors are not required. Wiring `T-taps" or threshold level. branches are permitted for Style 4(Class B) wiring. NP-100R(A) • Visible LED"blinks"when the unit is addressed(communicat- mounts in a DNR(A)/DNRW duct detector housing. ing with the fire panel)and latches on in alarm. Operation MECHANICALS Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25, or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Circuit • Mounts to:single-gang box,3.5"(8.89 cm)or 4.0"(10.16 cm) (SLC). It responds to regular polls from the system and reports octagonal box,or 4.0"(10.16 cm)square electrical box(using its type and status. a plaster ring—included). The addressable photoelectric sensor in the NP-100(A) series OTHER SYSTEM FEATURES has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient protec- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tion. sending an alarm level signal. Because of its unipolar chamber, • 94-VO plastic flammability rating. the NP-100(A) series is approximately two times more respon- • Low standby current. sive than most photoelectric sensors.This makes it a more sta- ble detector. DN-6995:D•2/11/2015—Page 1 of 2 17 • Detector Sensitivity Test INTELLIGENT BASES Each detector can have its sensitivity tested(required per NFPA NOTE:"A"suffix indicates ULC Listed model. 72, Chapter 14 on Inspection, Testing and Maintenance) when NOTE:For details about intelligent bases and their mounting, see installed/connected to a FireWarden-100-2 or FireWarden-50 DN-60054. addressable fire alarm control panel.The results of the sensitiv- ity test can be printed off the FireWarden-100-2 or FireWarden- B210LP(A): Plug-in detector base (included); standard U.S. 50 for record keeping. flanged low-profile mounting base. B210LPBP:Bulk pack of B210LP;package contains 10. Specification B501(A):Standard European flangeless mounting base. Voltage range: 15—32 VDC(peak). B501 BP: Bulk pack of B501;package contains 10. Standby current:300 NA @ 24 VDC. B200SR(A): Intelligent sounder base capable of producing LED current:6.5 mA @ 24 VDC(latched"ON"), sound output with ANSI Temporal 3 or continuous tone. Replaces 8501 BH series bases in retrofit applications. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B224RB(A): Plug-in System Sensor relay base. Screw termi- Size:2.1"(5.33 cm)high;base determines diameter. nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating:2.0 —B210LP(A):6.1"(15.5 cm)diameter. A @ 30 VDC resistive;0.3 A @ 110 VDC inductive; 1.0 A @ 30 —B501(A):4.1"(10.4 cm)diameter. VDC inductive. —B200SR(A):6.875"(17.46 cm)diameter. B224B1(A): Plug-in System Sensor isolator detector base. —B224RB(A):6.2"(15.748 cm)diameter. Maximum 25 devices between isolator bases(see DN-6994). Weight:3.6 oz.(102 g). ACCESSORIES Operating temperature range: for NP-100(A): 0°C to 49°C F110: Retrofit flange to convert B210LP(A) to match the (32°F to 120°F); for NP-100T(A):0°C to 38°C (32°F to 100°F). B710LP(A) profile,or to convert older high-profile bases to low- NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C (-4°F profile. to 158°F). F110BP:Bulk pack of F110;package contains 15. Temperature:0°C—49°C(32°F—120°F). F210: Replacement flange for B210LP(A)base. Relative humidity: 10%—93%,non-condensing. RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to a Listings U.S. single-gang electrical box. For use with B501(A) and B210LP(A)bases only. Listings and approvals below apply to the NP-100(A), NP- SMB600:Surface mounting kit 100T(A), and NP-100R(A) detectors. In some cases, certain M02-04-00:Test magnet. modules may not be listed by certain approval agencies,or list- ing may be in process.Consult factory for latest listing status. M02-09-00:Test magnet with telescoping handle. • UL Listed:S1115. XR2B: Detector removal tool.Allows installation and/or removal • ULC Listed:51115. of detector heads from bases in high ceiling applications. • CSFM:7272-0028:0231. XP-4:Extension pole for XR2B.Comes in three 5-foot(1.524 m) • MEA:243-02-E Vol.2. sections. • Maryland State Fire Marshal:permit 2173. T55-127-010: Detector removal tool without pole. • FM approved. BCbox of 06: Black detector covers for use with NP-100(A) only; box of 10. WCK-200B:White detector covers for use with NP-100(A)only; Product Line Information box of 10. NOTE:`A"suffix indicates ULC Listed model. NP-100: Addressable photoelectric detector; B210LP base included. NP-100A: Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TH:Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B210LP base included. NP-100RA: Same as NP-100R with ULC Listing for use with a NOTIFIER® and FireWarden® are registered trademarks of Honeywell DNRA duct detector housing;B210LPA base included. International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF 1 E O We cannot cover all specific applications or anticipate all requirements. MINOR BMAMMON'S All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier,Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6995:D•2/11/2015 18