Loading...
Specifications (4) Pe5,4c I?-- ar?? f 16-175-54r ? RECEIvED NOv277017 CITY OF TIGARD BUILDING DIVISION CALCULATION SUMMARY Project Name:OPTION CARE Drawing No. Project Location: 16195 SW72ND AVENUE City: TIGARD, OR 97224 Design Areas Design Area Name Calc.Mode (Model) Occupancy Area of otal Water Pressure Application Source ti) MM. M ® Density Pr in. M ® Pressure in. Calculated Hose Margin To IIMIIII Demand(HW) ON GP II ® Flow Heads ®� Streams INN 1500 MIN Required ®© Source 94 0.2 250 Date 11/9/2017 File:C:1 Project FileslOption Care1FP Drawings\OCP_1.dw9 Copyright©2002-2012 Tyco Fire Protection Products Page 1 t ' HYDRAULIC CALCULATIONS for Job Informn City: TIGARD, OR 97224 ProjectatioName.OPTION CARE Date:111812017 Contract No. Project Location: 16195 SW 72ND AVENUE Contractor Information PORTLAND, OR 97210 City: Name of Contractor: VIKING SPRINKLE E-mail:PORTLAND, .MCQ 97 10 oeVIKINGSPRINKLER.NET MARTI Address: 2345 NW FRONT AVE Phone Number: 503-227-1171 Name of Designer: MCQ Authority Having Jurisdiction: CITY OF TIGARD 1 Destgf1 CLEAN ROOM Remote Area Name Remote Area Location OH GP II Occupancy Classification 0.2 Density(gP mlft2) 1500 Area of Application(ft2) 120 12 c 2 0 1.�s-1;, Coverage per Sprinkler(ft2) 8�4c�, Sprinklers 0 0._.- S' Number of Calculated Sp 4 In Rack Demand(gpm) VIrtYi3 250 Special Heads �� 18 Hose Streams(gpm) 552.1 ire#`--7. '"""" Total Water Required(incl.Hose Streams)(gpm) 94 Required Pressure at Source(psi) Wet Type of System 963 gel Volume-Entire System (gal) Water Supply Information 03131117 72ND AVE&UPPER BOONES FERR Date W1 Location Source Notes File:C:\ Project Files\Option Care\FP Drawing s\OCP-1.dw9 Page 2 Copyright©2002-2012 Tyco Fire Protection Products Date 111912017 Job:OPTION CARE Node Labels: Off Diagram for Design Area : 1 Pipe Labels: Off lOntimi7pr Hydraulic Simnlifipol ♦1r5 VPI t,- Date 11/9/2017 File:C:1_Project Files 1Option Care\FP Drawings\OCP-1.dwg Copyright©2002-2012 Tyco Fire Protection Products Page 3 , Job:OPTION CARE Hydraulic Analysis for : 1 Calculation Info Demand Calculation Mode Hazen-Williams Hydraulic Model Water @ 60F (15.6C) FluidluidName V ) N/A for Hazen-Williams calculation. Fluid Weight, ( N/A for Hazen-Williams calculation. Fluid Dynamic Vissccoosity, (Ib�s/ft2) Water Supply Parameters Supply 1 :W1 IIIIIIIIIr0� 110 6826 Supply Analysis ResidualAvailable Static Pressure Total Demand Required Pressure Flow Pressure (psi) (gpm) (gpm) (psi) Pressure Node at Source (psi) (psi) 110 86 6826 109.9 552.1 MEI W1 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) 250 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 250 Total Hose Flow(gpm) Sprinklers 302.1 Ovehead Sprinkler Flow(gpm) 0 InRack Sprinkler Flow(gpm) Other(custom defined)Sprinkler Flow(gpm) 0 302.1 Total Sprinkler Flow(gpm) Other 0 Required Margin of Safety(psi) 94 W1 -Pressure(psi) 302.1 W1 -Flow(gpm) N/A Demand w/o System Pump(s) File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Page 4 Copyright©2002-2012 Tyco Fire Protection Products Date 11/9/2017 Job:OPTION CARE Hydraulic Analysis for: 1 Ss.pot it 'E1&rn t?tEfiBnd *Add SKS Hos. 150. { ( i t 140 rla t , 130 • 110 t 1. • 1'® , I $O I ti ? { .. �{ t ! i r i jj , i i 30 1 20 Ya. _... i 0 0 20:425.003000 3506 4006 4600 5000 5500 0400 0600 7000 Flow,gpm °1 II Date 11/9/2017 File:Cl Project Files\Option Care1FP Drawings IOCP-1.dwg Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job:OPTION CARE Hydraulic Analysis for : 1 Graph Labels 1111111111111111111112211 Label Description Flow (gpm) Pressure (psi)® 0 110 Supply point#1 -Static ® 6826 86 Supply point#2-Residual 0 D1 Elevation Pressure 94 D2 System Demand 302.1 94 D3 System Demand+Add.Out.Hose Curve Intersections &Safety Margins Safety Margin Intersection Flow (gpm) Pressure (psi) Flow (gpm) Pressure (psi) @ 109.9 329 Supply 111111011111111123/1111 Calculated Open Heads Required Type Coverage K-Factor Density Flow UM Density Flow MN Head Ref. Head (psi) __® (9pm/Psi'/z) (gpm/ft2) (gpm) (psi) (gPm/ftz) (gpm) MIN 0.228 Overhead 120 0.2 Sprinkler MOM v 0.208 Overhead 120 0.2 10 Sprinkler 0.201 Overhead 120 0.2 1111 EOM MOM Sprinkler 0.207 Overhead 1111 120 Sprinkler 0.2 EOM EIMIli 0INSIN .2 Overhead II 120 0 2 Nala Sprinkler 0.206 Overhead 120ill 0 2 MEM MEM Sprinkler 1111 0.23 Overhead111 120IIIII 0 2 Sprinkler 0.207 Overhead 120 0.2 IIMIN MEM Sprinkler ® 20.9 IIII 0.213in 0.2 ENO Overhead 120 11111 Sprinkler 11111 0.205 Overhead 120 0 2 Sprinkler ® 20.4 IIIII 0.211On Overhead 120 0 2 Sprinkler ® 11111110 0.202 Overhead 120 0 2 Sprinkler 1111 SIMIN File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Page 6 Copyright©2002-2012 Tyco Fire Protection Products Date 1119/2017 Job:OPTION CARE Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y gpm/psis/a ft ft psi ft2 ft 2 HEAD 5.6 0 749.01 Overhead Sprinkler 0 120 176.2 11 HEAD 5.6 0 789.01 Overhead Sprinkler 0 120 174.2 9 HEAD 5.6 0 779.01 Overhead Sprinkler 0 120 174.2 7 HEAD 5.6 0 769.01 Overhead Sprinkler 0 120 174.2 3 HEAD 5.6 0 749.01 Overhead Sprinkler 0 120 166.2 12 HEAD 5.6 0 789.01 Overhead Sprinkler 0 120 164.2 5 HEAD 5.6 0 759.01 Overhead Sprinkler 0 120 174.2 10 HEAD 5.6 0 779.01 Overhead Sprinkler 0 120 164.2 8 HEAD 5.6 0 769.01 Overhead Sprinkler 0 120 164.2 6 HEAD 5.6 0 759.01 Overhead Sprinkler 0 120 164.2 1 HEAD 5.6 0 737.01 Overhead Sprinkler 0 120 164.2 4 HEAD 5.6 0 753.01 Overhead Sprinkler 0 120 160.2 011 NODE 9 749.76 Node us.Tee 0 166.2 023 NODE 788.26 Node us.Tee 0 9 164.2 029 NODE 778.26 Node us.Tee 0 9 164.2 035 NODE 768.26 Node us.Tee 0 9 164.2 382 NODE 758.26 Node us.Tee 0 9 164.2 021 NODE 788.26 Node us.Tee 0 9 161.7 020 NODE 778.26 Node us.Tee 0 9 161.7 006 NODE 737.76 Node us.Tee 0 9 161.7 005 NODE 749.76 Node us.Tee 0 9 161.7 019 NODE 9 768.26 Node us.Tee 0 161.7 004 NODE 753.76 Node us.Tee 0 9 161.7 017 NODE 758.26 Node us.Tee 0 9 161.7 018 NODE 9 761.06 Node us.Tee 0 161.7 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 7 r , Job:OPTION CARE Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y gpm/psis ft ft psi ft2 ft 041 NODE 9 761.06 Node us.Tee 0 151.47 075-0 NODE 9 762.06 Node coupling 0 156.75 075-I NODE 9 762.06 Node coupling 0 157.07 078 NODE 14.33 762.06 Node us.Tee 0 164.03 079 NODE 14.33 760.67 Node us.Tee 0 164.03 080 NODE 14.33 748.58 Node us.Tee 0 164.03 081 NODE 14.33 736.08 Node us.Tee 0 164.03 082 NODE 724 14.33 Node us.Tee 0 164.03 083 NODE 711.5 14.33 Node us.Tee 0 164.03 084 NODE 14.33 699.42 Node us.Tee 0 164.03 085 NODE 14.33 686.92 Node us.Tee 0 164.03 086 NODE 14.33 674.75 Node us.Tee 0 164.03 087 NODE 14.33 662.25 Node us.Tee 0 164.03 101 NODE 14.33 662.25 Node us.Tee 0 108.03 103 NODE 14.33 674.75 Node us.Tee 0 108.03 104 NODE 14.33 686.92 Node us.Tee 0 108.03 105 NODE 14.33 699.42 Node us.Tee 0 108.03 106 NODE 711.5 14.33 Node us.Tee 0 108.03 107 NODE 724 14.33 Node us.Tee 0 108.03 108 NODE 14.33 736.08 Node us.Tee 0 108.03 146 NODE 14.33 773.17 Node us.Tee 0 164.03 109 NODE 14.33 748.58 Node us.Tee 0 108.03 110 NODE 14.33 760.67 Node us.Tee 0 108.03 111 NODE 14.33 773.17 Node us.Tee 0 108.03 145 NODE 14.33 785.25 Node us.Tee 0 164.03 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:OPTION CARE Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y gpm/psis/z ft ft psi ft2 ft 112 NODE 14.33 785.25 Node us.Tee 0 108.03 144 NODE 14.33 793.25 Node us.Tee 0 164.03 113 NODE 14.33 793.25 Node us.Tee 0 108.03 143 NODE 14.33 797.75 Node us.Tee 0 164.03 114 NODE 14.33 797.75 Node us.Tee 0 108.03 142 NODE 14.33 809.83 Node us.Tee 0 164.03 115 NODE 14.33 809.83 Node us.Tee 0 108.03 116 NODE 14.33 822.33 Node us.Tee 0 108.03 141 NODE 14.33 822.33 Node us.Tee 0 164.03 117 NODE 14.33 834.42 Node us.Tee 0 108.03 140 NODE 14.33 834.42 Node us.Tee 0 164.03 118 NODE 14.33 846.92 Node us.Tee 0 108.03 139 NODE 14.33 846.92 Node us.Tee 0 164.03 119 NODE 14.33 859 Node us.Tee 0 108.03 120 NODE 14.33 871.5 Node us.Tee 0 108.03 121 NODE 14.33 883.58 Node us.Tee 0 108.03 122 NODE 14.33 896.08 Node us.Tee 0 108.03 138 NODE 14.33 859 Node us.Tee 0 164.03 137 NODE 14.33 871.5 Node us.Tee 0 164.03 136 NODE 14.33 883.58 Node us.Tee 0 164.03 134 NODE 14.33 896.08 Node us.Tee 0 164.03 135 NODE 14.33 888.96 Node us.Tee 0 164.03 278 NODE 14.33 888.96 Node us.90 0 185.94 279-0 NODE 8 42 888.96 Node coupling 0 185.94 279-I NODE 7 67 888.96 Node coupling 0 185.94 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:OPTION CARE Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Hgroup K-Fact. Elev X Type Fitting Stat. Pres. Coverage Y gpm/psi1/2 ft ft psi ft2 ft 280-0 NODE 5.63 888.96 Node coupling 0 185.94 280-I NODE 3.79 888.96 Node coupling 0 185.94 281 NODE 888.96 Node coupling 0 0'5 185.94 290 NODE3 946.49 Node us.Tee 0 199.03 W46.4 SUPPLY Supply -3 g0 979 0 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: (1 ft) 0 5.6 24 1 3x(us.90)=6 20.42 120 18.4 011 9 24 1.049 6 0.1817 -3.9 26.42 4.8 011 9 24.7 1 lx(us.Tee-Br)=5 4.5 120 19.3 005 9 48.7 1.049 5 0.6738 0 9.5 6.4 005 9 27.4 2 4 120 25.7 004 9 76.1 2.067 0 0.0566 0 4 0.2 004 9 27.7 2 4.5 120 25.9 017 9 103.7 2.067 0 0.1005 0 4.5 0.5 017 9 50.5 2 1x(us.Tee-Br)=10 2.8 120 26.3 018 9 154.2 2.067 10 0.2094 0 12.8 2.7 018 9 147.9 2 lx(us.Tee-Br)=10 10.24 120 29 041 9 302.1 2.067 10 0.7278 0 20.24 14.7 041 9 0 2.5 lx(coupling)=1 6.29 120 43.8 075-0 9 302.1 2.469 lx(us.90)=6 7 0.3063 0 13.29 4.1 075-0 9 0 2.5 0.32 0 47.8 BFV-N 075-I 9 302.1 0 0 7.4884 0 *** 0.32 2.4 075-I 9 0 2.5 lx(us.Tee-Br)=12 12.28 120 50.2 078 14.33 302.1 2.469 2x(us.90)=12 24 0.3063 -2.3 36.28 11.1 078 14.33 -80 2.5 11.11 120 59 146 14.33 222.1 2.635 0 0.1262 0 11.11 1.4 146 14.33 -11.8 2.5 12.08 120 60.4 145 14.33 210.2 2.635 0 0.114 0 12.08 1.4 145 14.33 -7.6 2.5 8 120 61.8 144 14.33 202.7 2.635 0 0.1065 0 8 0.9 144 14.33 -5 2.5 4.5 120 62.7 143 14.33 197.7 2.635 0 0.1017 0 4.5 0.5 143 14.33 -3.8 2.5 12.08 120 63.1 142 14.33 193.9 2.635 0 0.0982 0 12.08 1.2 142 14.33 -0.7 2.5 12.5 120 64.3 141 14.33 193.2 2.635 0 0.0975 0 12.5 1.2 141 14.33 3.3 2.5 12.08 120 65.5 140 14.33 196.5 2.635 0 0.1006 0 12.08 1.2 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x(name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 140 14.33 5.9 2.5 12.5 120 66.7 139 14.33 202.4 2.635 0 0.1063 0 12.5 1.3 139 14.33 9.3 2.5 12.08 120 68.1 138 14.33 211.7 2.635 0 0.1155 0 12.08 1.4 138 14.33 13.3 2.5 12.5 120 69.5 137 14.33 225 2.635 0 0.1293 0 12.5 1.6 137 14.33 18.2 2.5 12.08 120 71.1 136 14.33 243.3 2.635 0 0.1494 0 12.08 1.8 136 14.33 23.7 2.5 1x(us.Tee-Br)=16.47 5.38 120 72.9 135 14.33 266.9 2.635 16.47 0.1774 0 21.85 3.9 135 14.33 35.1 2.5 lx(us.90)=8.24 21.92 120 76.8 278 14.33 302.1 2.635 8.24 0.2231 0 30.15 6.7 278 14.33 0 4 lx(coupling)=1.32 5.91 120 83.5 279-0 8.42 302.1 4.26 1.32 0.0215 2.6 7.23 0.2 279-0 8.42 0 4 0.75 0 86.2 Gate A2360 279-I 7.67 302.1 0 0 0.0115 0.3 *** 0.75 0 279-I 7.67 0 4 lx(coupling)=1.32 2.05 120 86.5 280-0 5.63 302.1 4.26 1.32 0.0215 0.9 3.36 0.1 280-0 5.63 0 4 1.83 0 87.5 Ames3000SS 280-I 3.79 302.1 0 0 1.2044 0.8 *** 1.83 2.2 280-I 3.79 0 4 1x(coupling)=1.32 3.29 120 90.5 281 0.5 302.1 4.26 1.32 0.0215 1.4 4.61 0.1 281 0.5 0 6 lx(us.Tee-Br)=51.84 74.12 140 92 290 -3 302.1 6.4 2x(us.90)=48.39 100.23 0.0022 1.5 174.35 0.4 290 -3 0 8 200 140 93.9 W1 -3 302.1 8.55 0 0.0005 0 200 0.1 W1 94 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright 0 2002-2012 Tyco Fire Protection Products Page 12 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Path No: 2 11 0 5.6 24.1 1 3x(us.90)=6 20.42 120 18.5 023 9 24.1 1.049 6 0.1831 -3.9 26.42 4.8 023 9 24.8 1 lx(us.Tee-Br)=5 2.5 120 19.5 021 9 48.9 1.049 5 0.6788 0 7.5 5.1 021 9 0 2 10 120 24.5 020 9 48.9 2.067 0 0.025 0 10 0.2 020 9 49.1 2 10 120 24.8 019 9 98 2.067 0 0.0905 0 10 0.9 019 9 49.9 2 lx(us.Tee-Br)=10 7.2 120 25.7 018 9 147.9 2.067 10 0.1939 0 17.2 3.3 018 29 Path No: 3 90 5.6 24.2 1 3x(us.90)=6 20.42 120 18.7 029 9 24.2 1.049 6 0.1846 -3.9 26.42 4.9 029 9 24.9 1 lx(us.Tee-Br)=5 2.5 120 19.7 020 9 49.1 1.049 5 0.6845 0 7.5 5.1 020 24.8 Path No: 4 7 0 5.6 24.6 1 3x(us.90)=6 20.42 120 19.3 035 9 24.6 1.049 6 0.1902 -3.9 26.42 5 035 9 25.3 1 lx(us.Tee-Br)=5 2.5 120 20.4 019 9 49.9 1.049 5 0.7049 0 7.5 5.3 019 25.7 Path No: 5 3 0 5.6 24.7 1 1x(us.Tee-Br)=5 10.42 120 19.4 011 9 24.7 1.049 2x(us.90)=4 9 0.1916 -3.9 19.42 3.7 011 19.3 Path No: 6 12 0 5.6 24.8 1 lx(us.Tee-Br)=5 10.42 120 19.6 023 9 24.8 1.049 2x(us.90)=4 9 0.193 -3.9 19.42 3.7 023 19.5 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Path No: 7 5 0 5.6 24.9 1 3x(us.90)=6 20.42 120 19.7 382 9 24.9 1.049 6 0.1941 -3.9 26.42 5.1 382 9 25.6 1 lx(us.Tee-Br)=5 2.5 120 21 017 9 50.5 1.049 5 0.7197 0 7.5 5.4 017 26.3 Path No: 8 10 0 5.6 24.9 1 1x(us.Tee-Br)=5 10.42 120 19.8 029 9 24.9 1.049 2x(us.90)=4 9 0.1946 -3.9 19.42 3.8 029 19.7 Path No: 9 8 0 5.6 25.3 1 lx(us.Tee-Br)=5 10.42 120 20.4 035 9 25.3 1.049 2x(us.90)=4 9 0.2005 -3.9 19.42 3.9 035 20.4 Path No: 10 6 0 5.6 25.6 1. 1x(us.Tee-Br)=5 10.42 120 20.9 382 9 25.6 1.049 2x(us.90)=4 9 0.2046 -3.9 19.42 4 382 21 Path No: 11 1 0 5.6 27.4 1 lx(us.Tee-Br)=5 12.92 120 23.9 006 9 27.4 1.049 3x(us.90)=6 11 0.2321 -3.9 23.92 5.6 006 9 0 2 12 120 25.6 005 9 27.4 2.067 0 0.0085 0 12 0.1 005 25.7 Path No: 12 4 0 5.6 27.7 1 lx(us.Tee-Br)=5 11.92 120 24.4 004 9 27.7 1.049 3x(us.90)=6 11 0.2363 -3.9 22.92 5.4 004 25.9 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Path No: 13 078 14.33 0 2.5 1.39 120 59 079 14.33 80 2.635 0 0.0191 0 1.39 0.0 079 14.33 -15.8 2.5 12.08 120 59.1 080 14.33 64.2 2.635 0 0.0127 0 12.08 0.2 080 14.33 -12.9 2.5 12.5 120 59.2 081 14.33 51.3 2.635 0 0.0084 0 12.5 0.1 081 14.33 -10.6 2.5 12.08 120 59.3 082 14.33 40.8 2.635 0 0.0055 0 12.08 0.1 082 14.33 -8.8 2.5 12.5 120 59.4 083 14.33 31.9 2.635 0 0.0035 0 12.5 0.0 083 14.33 -7.5 2.5 12.08 120 59.4 084 14.33 24.4 2.635 0 0.0021 0 12.08 0.0 084 14.33 -6.6 2.5 12.5 120 59.5 085 14.33 17.8 2.635 0 0.0012 0 12.5 0.0 085 14.33 -6.1 2.5 12.17 120 59.5 086 14.33 11.7 2.635 0 0.0005 0 12.17 0 086 14.33 -5.8 2.5 lx(us.Tee-Br)=16.47 12.5 120 59.5 087 14.33 5.9 2.635 16.47 0.0002 0 28.97 0 087 14.33 0 1.25 3x(us.Tee-Br)=18 57.33 120 59.5 101 14.33 5.9 1.38 18 0.0036 0 75.33 0.3 101 14.33 0 2 12.5 120 59.7 103 14.33 5.9 2.157 0 0.0004 0 12.5 0 103 14.33 5.8 2 12.17 120 59.8 104 14.33 11.7 2.157 0 0.0014 0 12.17 0.0 104 14.33 6.1 2 12.5 120 59.8 105 14.33 17.8 2.157 0 0.0031 0 12.5 0.0 105 14.33 6.6 2 12.08 120 59.8 106 14.33 24.4 2.157 0 0.0056 0 12.08 0.1 106 14.33 7.5 2 12.5 120 59.9 107 14.33 31.9 2.157 0 0.0092 0 12.5 0.1 107 14.33 8.8 2 12.08 120 60 108 14.33 40.8 2.157 0 0.0145 0 12.08 0.2 108 14.33 10.6 2 12.5 120 60.2 109 14.33 51.3 2.157 0 0.0222 0 12.5 0.3 109 14.33 12.9 2 12.08 120 60.4 110 14.33 64.2 2.157 0 0.0336 0 12.08 0.4 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 15 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) 110 14.33 15.8 2 12.5 120 60.9 111 14.33 80 2.157 0 0.0505 0 12.5 0.6 111 14.33 11.8 2 12.08 120 61.5 112 14.33 91.9 2.157 0 0.0652 0 12.08 0.8 112 14.33 7.6 2 8 120 62.3 113 14.33 99.4 2.157 0 0.0755 0 8 0.6 113 14.33 5 2 4.5 120 62.9 114 14.33 104.4 2.157 0 0.0827 0 4.5 0.4 114 14.33 3.8 2 12.08 120 63.2 115 14.33 108.2 2.157 0 0.0883 0 12.08 1.1 115 14.33 0.7 2 12.5 120 64.3 116 14.33 108.9 2.157 0 0.0893 0 12.5 1.1 116 14.33 -3.3 2 12.08 120 65.4 117 14.33 105.6 2.157 0 0.0844 0 12.08 1 117 14.33 -5.9 2 12.5 120 66.5 118 14.33 99.7 2.157 0 0.0758 0 12.5 0.9 118 14.33 -9.3 2 12.08 120 67.4 119 14.33 90.4 2.157 0 0.0632 0 12.08 0.8 119 14.33 -13.3 2 12.5 120 68.2 120 14.33 77 2.157 0 0.0471 0 12.5 0.6 120 14.33 -18.2 2 12.08 120 68.8 121 14.33 58.8 2.157 0 0.0286 0 12.08 0.3 121 14.33 -23.7 2 lx(us.Tee-Br)=12.31 12.5 120 69.1 122 14.33 35.1 2.157 12.31 0.011 0 24.81 0.3 122 14.33 0 1.25 3x(us.Tee-Br)=18 57.33 120 69.4 134 14.33 35.1 1.38 18 0.0969 0 75.33 7.3 134 14.33 0 2.5 lx(us.Tee-Br)=16.47 7.13 120 76.7 135 14.33 35.1 2.635 16.47 0.0042 0 23.6 0.1 135 76.8 Path No: 14 146 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 60.4 111 14.33 11.8 1.38 24 0.0129 0 81.33 1 111 61.5 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 16 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Path No: 15 145 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 61.8 112 14.33 7.6 1.38 24 0.0056 0 81.33 0.5 112 62.3 Path No: 16 144 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 62.7 113 14.33 5 1.38 24 0.0026 0 81.33 0.2 113 62.9 Path No: 17 143 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 63.1 114 14.33 3.8 1.38 24 0.0015 0 81.33 0.1 114 63.2 Path No: 18 142 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 64.3 115 14.33 0.7 1.38 24 0.0001 0 81.33 0 115 64.3 Path No: 19 079 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.1 110 14.33 15.8 1.38 24 0.022 0 81.33 1.8 110 60.9 Path No: 20 080 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.2 109 14.33 12.9 1.38 24 0.0152 0 81.33 1.2 109 60.4 Path No: 21 081 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.3 108 14.33 10.6 1.38 24 0.0105 0 81.33 0.9 108 60.2 Path No: 22 082 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.4 107 14.33 8.8 1.38 24 0.0075 0 81.33 0.6 107 60 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 17 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Path No: 23 083 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.4 106 14.33 7.5 1.38 24 0.0055 0 81.33 0.5 106 59.9 Path No: 24 084 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.5 105 14.33 6.6 1.38 24 0.0044 0 81.33 0.4 105 59.8 Path No: 25 085 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.5 104 14.33 6.1 1.38 24 0.0037 0 81.33 0.3 104 59.8 Path No: 26 086 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 59.5 103 14.33 5.8 1.38 24 0.0034 0 81.33 0.3 103 59.8 Path No: 27 116 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 65.4 141 14.33 3.3 1.38 24 0.0012 0 81.33 0.1 141 65.5 Path No: 28 117 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 66.5 140 14.33 5.9 1.38 24 0.0036 0 81.33 0.3 140 66.7 Path No: 29 118 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 67.4 139 14.33 9.3 1.38 24 0.0083 0 81.33 0.7 139 68.1 Path No: 30 119 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 68.2 138 14.33 13.3 1.38 24 0.016 0 81.33 1.3 138 69.5 File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 18 Job:OPTION CARE Hydraulic Calculations PIPE INFORMATION Path No: 31 120 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 68.8 137 14.33 18.2 1.38 24 0.0287 0 81.33 2.3 137 71.1 Path No: 32 121 14.33 0 1.25 4x(us.Tee-Br)=24 57.33 120 69.1 136 14.33 23.7 1.38 24 0.0466 0 81.33 3.8 136 72.9 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 28.88 ft/s occurs in the following pipe(s): (041-018) *** Device pressure loss(gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing.The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 19 . _ Job:OPTION CARE Device Graphs Pressure vs. Flow Function Design Area: I; Supply Ref.:WI: Supply Name:VV1 125120 1 • 1 . 115 • ' , 110 . . 105 100 95 . - SO Cr 75 1" 1 70 60 - 55 50 45; - I , 35 i . . ., 30 20 . . 15 10 flow,gpm Pressure Loss Function Design Area: 1; DFP Ref.: 459 (Ames3000SS, Size— 4); Inlet Node; 280-1; Outlet Node: 280-0 I ..,.., 1 , 1 " $45- I i 1 1- . i 7A5- • c„. I.. = _ I , ' in 5 45- • , I VI I . e _ D. 445:1 1 ' , - 1 3 45- i I 2.24,11'psi AtD 302.1 gpm . 1 245 . 4 eler: .. ., . . . . , ! . 145 t ' i , . . . 045-- I , , ^-• .—, rq C4 rn rn -er .s. ,..n .1 NO ..C. r.. e-- F low,gpm File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 20 Job:OPTION CARE Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 458 (BFV-N, Size Z5); Inlet Node: 075-I; Outlet Node: 075-0 r 5 511- __ , .. E 4,511- i O 11 �. i i F I I . 2.4 psi Q 302.1 ppm ry 611 r jOr ; i 1,e,11 011 i j . I r i r r , r , , r r r � r r � r e r Flow,gprn Pressure Loas Function Design Area: 1; Valve Ref.: 460 (Gate An6o, Size= 4); Inlet Node: 279.I; Outlet Node: 279-0 . i ci 743- V a 0243- . 1. i 0psi©,302.1 gpm ..r r i r r r 1 r r r p o on o 40 O N "N N oN Flow,gpm File:C:\_Project Files\Option Care\FP Drawings\OCP-1.dwg Date 11/9/2017 Copyright©2002-2012 Tyco Fire Protection Products Page 21