Report (51) f `a. -Pl°5ZO/` —' V/� FIRE SPRINKLER RECEIVED Product Data For: NOV 2 7 2017 CITY OF TIGARD BUILDING DIVISION OPTION CARE 16195 SW 72ND AVENUE TIGARD, OR 97224 PREPARED BY: FIRE PROTECTION Viking Automatic Sprinkler Co. 3245 NW Front Avenue Portland, OR 97210 24 Hrs 0: 503.227.1171 F: 503.227.1552 OR CCB #64837 • Metro Lic #2816 • WA LIC #VI-KI-NA-5373NT Boise • Longview • Medford • Portland • Seattle Submittal Date: November 09, 2017 TABLE OF CONTENTS SECTION#1-SPRINKLER HEADS • Viking VK100 Upright Sprinkler • Viking VK102 Pendent Sprinkler • Viking VK462 Pendent Concealed Sprinkler • Viking Sprinkler Escutcheons • Viking Sprinkler Clean Room Cover Plate • Viking Sprinkler Expansion Plate • Viking 6 Head Box SECTION#2-VALVES • Victaulic Grooved Butterfly Valve • Victaulic Zone Valve with Inspectors Test r , Page 1 of 6 NIKING ® MICROMATIC®STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-9454501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com 1. DESCRIPTION The Viking Micromatic® Standard Response Upright VK100 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes and tem- perature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts.(Note:FM Global approves the ENT coating as corrosion resistant.FM Global has no approval classification for Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed)on deluge systems.Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS cOus cULus Listed: Category VNIV > FM Approved: Classes 2001, 2002,2015, 2017, 2043 NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi(0.5 bar)t Maximum Working Pressure: 175 psi(12 bar)wwp Factory tested hydrostatically to 500 psi(34.5 bar) Thread size: 1/2"NPT, 15 mm BSP Nominal K-Factor:5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to-65 °F(-55°C) Overall Length:2-3/8"(60 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). **Metric K-factor measurement shown is in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers:Belleville Spring-Exposed, Screw and Pipcap-ENT plated. ttNot for FM Approval. Ordering Information:(Also refer to the current Viking price list.) Order Micromatic®Standard Response Upright VK100 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix:Brass=A, Chrome=F,White Polyester=M-/W, Black Polyester=M-/B,Wax Coated=C, Wax Over Polyester= V-/W, ENT=JN Temperature Suffix: 135 °F(57 °C)=A, 155 °F(68 °C)= B, 175 °F(79 °C)= D, 200 °F(93 °C)= E, 212 °F(100 °C)=M, 286 °F (141 °C)=G,360°F(182 °C)=H, 500 °F(260 °C)=L. For example, sprinkler VK100 with a 1/2"thread, Brass finish and a 155°F(68 °C)temperature rating=Part No. 12986AB Available Finishes And Temperature Ratings: Refer to Table 1. Form No. F_052014 17.10.05 Rev 17.1 Replaces Form No.F_052014 Rev 16.2 (Added new standard wrench 21475) , 1 Page 2 of 6 NIKINGII(I1 ® MICROMATIC®STANDARD RESPONSE UPR TECHNICAL DATA SPRINKLER VK1 OIGHT(K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings Ml 49058 Telephone: � O8this Fax:269418-1680 Email: rp.com Vi heVikngwebs t for the latest edtionof techncal da a page:www•ik nggouppinecom Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench:Part No.21475M/B(available since 2017). B.Standard Wrench for Wax Coated Sprinklers:Part No. 10896W/B C.Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/B*(available since 2006) *A1/2"ratchet is required(not available from Viking). Sprinkler Cabinets: A.Six-head capacity:Part No.01724A(available since 1971) B.Twelve-head capacity: Part No.01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION the lfire conditions,ssmbly.Water flowing through'n the glass the sprinkler oaf ce strikes the spank ergdeflector,,forming la uniform spray pattern sealing spring asse y to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic®Standard Response Upright Sprinkler VK100 is available through a network of domestic and international distributors.See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Cap Wrench Flat 21475 10896 Standard Sprinkler Standard Sprinkler Wrench for Wax Wrench 21475M/B Coated Sprinklers 10896W/B Figure 1: Standard Sprinkler Wrenches Form No.F_052014 17.10.05 Rev 17.1 Page 3 of 6 \ilium® MICROMATIC®STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269.818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F(57 °C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38 °C) Red Intermediate 175 °F(79°C) 150°F(65°C) Yellow Intermediate 200 °F(93°C) 150°F(65 °C) Green High 286 °F(141 °C) 225°F(107°C) Blue Extra High 360°F(182°C) 300°F(149 °C) Mauve Ultra High3 500 °F(260 °C) 465°F(240°C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester,and ENT Corrosion-Resistant Coatings4:White Polyester,Black Polyester,and Black PTFE in all temperature ratings.ENT in all temperature ratings except 135°F(57 °C). Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: 155 °F(68°C)Lt. Brown Wax 175 °F(79 °C)Brown Wax 200°F(93 °C)Brown Wax 286°F(141 °C)Dk. Brown Wax5 Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C), response time may be severely retarded. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings.For ENT coated automatic sprinklers,the waterway is coated. 5 Wax melting point is 170°F(76°C)for 286°F(141 °C)temperature rated sprinklers. Form No.F_052014 17.10.05 Rev 17.1 , 1 Page 4 of 6 ® MICROMATIC®STANDARD II(IIsK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com Listings and Approvals' Sprinkler Thread Size Nominal K-Factor Overall Length (Refer also to UL Design Criteria.) Base Part SIN Number' NPT BSP U.S. metr)c2 Inches mm cULus. VdS LPCB (E Standard Orifice 12986 VK100 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B3,C4,D2,E5 — -- 12993 VK100 — 15 mm 5.6 80.6 2-1/4" 57 Al,B3,C4,D2,E5 — — NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 10138 VK100 1/2" 15 mm 5.6 80.6 2-1/4" 57 Al,B3,C4,D2,E5 — — 10193 VK100 — 15 mm 5.6 80.6 2-1/4" 57 Al,B3,C4,D2,E5 — — — Approved Temperature Ratings A-135°F(57°C),155°F(68°C), 175°F(79°C), Approved Finishes 200°F(93°C),286°F(141 °C),and 360°F(182 °C) 1 -Brass,Chrome,White Polyester'',and Black Polyester'•' B-135°F(57°C),155°F(68°C),175°F(79°C), 2-Brass and Chrome and 200°F(93°C) 3-Wax-Coated Brass and Wax Over Polyester' C-286"F(141 "C) 4-High Temperature 200°F(93°C)Wax Coating(corrosion resistant);maximum ambient tem- D-500°F(260°C)7 perature allowed at ceiling=150°F(65°C) E - 155 °F (68 °C), 175 °F (79 "C), 200 °F (93 5-ENT' °C),286°F(141 °C), 360°F(182°C),and 500"F (260°C)7 Footnotes 1 Base part number is shown.For complete part number,refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 'cULus Listed as corrosion resistant. 'Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300 r*F(149e 49 C).Where ambient temperature rated sprinkler heUltra-Highmay ie tsemperature urerated sprinkler is significantly reduced below 300°F(149°C), the { cULus Listina Reauirements: The Viking Micromatic®Standard Response Upright Sprinkler VK100 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light,Ordinary,and Extra Hazard occupancies. •The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT:Always refer to Bulletin Form No.F_091699-Care and Handling of Sprinklers.Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. nto dpi o. Viking nspri ds ofs are NFPA,o be in- stalled in accordance with the latest edition of Viking technical data, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards,whenever applicable. Form No.F_052014 17.10.05 Rev 17.1 1 ' r Page 5 of 6 N11<ING MICROMATIC®STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com Sprinkler Base Thread Size Nominal K-Factor Overall Length Part Number' SINFM Approvals' NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) Standard Orifice 12986 VK100 1/2" 15 mm 5.6 80.6 2-1/4" 12993 VK100 57 Al,B2,C3,D1,E4,F6 15 mm 5.6 80.6 2-1/4" 57 NOTICE-Product Below-Limited Availability(Contact Local Viking Office) Al,D7,E4,F6,G5 10138 VK100 1/2" 15 mm 5.6 80.6 2-1/4" 10193 VK100 57 Al,B2,C3,D1,E4,F6 15 mm 5.6 80.6 2-1/4" 57 Approved Temperature Ratings Al,G5,D1,E4,F6 A-135°F(57°C), 155°F(68°C), 175°F(79°C),200 °F(93°C),212°F(100°C),286°F(141°C),and 360°F Approved Finishes (182°C) 1 -Brass,Chrome,White Polyester',and Black Polyester" B-135°F(57°C),155°F(68°C),175°F(79°C),200°F 2-Wax-Coated Brass(corrosion resistant) (93°C)and 212°F(100°C) C-286°F(141 °C) 3-High Temperature 200°F(93°C)Wax Coating(corrosion resistant);maximum ambient E-155°F(68°C) 4-Wax-Coated Brass and Wax Over Polyesters F-155°F(68°C), 175°F(79°C),200°F(93°C),286°F (141 °C),360°F(182°C),and 500°F(260°C)5 5-White Polyester and Wax-Coated Brass(corrosion resistant) G-135°F(57°C),155°F(68°C), 175°F(79°C),and 6 ENT6 200°F(93°C) Footno s 'Base part number is shown.For complete part number,refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 'Other colors are available on request with the same Approvals as the standard colors. s Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. R EKARRE yal Reauiromn • The Viking Micromatic® Standard Response Upright Sprinkler VK100 is is FM Approved as standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data 9 p Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to:minimum water supply requirements,hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No.F 091699-Care and Handling of Sprinklers.Also refer to page SR1-3 for gen- eral care,installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. Form No.F_052014 17.10.05 Rev 17.1 Page 6 of 6 NIIIKING® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269945- 50e 8is lEmail:418-1680 rp.com Visit the Vik9gWs t for the latest edtionof tht chncada a page:www•vika990pingcom Sprinkler wrench 13577WIB** must be used for installing wax coated sprinklers. Step 1:Carefully slide the t wrench sideways around the deflector,ensuring engage- ment with the sprinklger wrench flats. Wax Coated Upright Sprinkler **A 112"ratchet is required Step 2: Carefully press the wrench downward and ensure engagement with the sprinkler (not available from Viking) wrench flats. Figure 2:Socket Wrench 13577W1B for Wax Coated Sprinklers Replaces Form No.F_052014 Rev 16.2 Form No.F_052014 17.10.05 Rev 17.1 (Added new standard wrench 21475) Page 1 of 7 ® MICROMATIC®STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION The Viking Micromatic® Standard Response Pendent VK102 Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and X, temperature ratings to meet design requirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts.(Note:FM Global approves the ENT coating as corrosion resistant.FM Global has no approval classification for Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed)on deluge systems. Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS c gL OS cULus Listed: Category VNIV e ". FM Approved: Class Series 2000 vas VdS Approved: Certificate G414006&G414004 tj LPCB Approved E CE Certified:Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2021 0CCCF Approved:Approved by the China Certification Center for Fire Products(CCCF) NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi(0.5 bar)t Maximum Working Pressure: 175 psi(12 bar)wwp Factory tested hydrostatically to 500 psi(34.5 bar) Thread size: 1/2"NPT, 15 mm BSP Nominal K-Factor:5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to-65°F(-55°C) Overall Length:2-1/4"(57 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000tt or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly:Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. tfNot for FM Approval. Ordering Information:(Also refer to the current Viking price list.) Order Micromatic®Standard Response Pendent VK102 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix:Brass=A, Chrome= F,White Polyester=M-/W, Black Polyester=M-/B,Wax Coated=C, Wax Over Polyester= V-/W, ENT=JN Form No.F_031414 17.10.05 Rev 17.2 Replaces Form No.F_031414 Rev 17.1 (Added new standard wrench 21475) Page 2 of 7 II(IIK ® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Temperature Suffix: 135 °F (57 °C)=A, 155°F(68°C)= B, 175°F (79°C)= D,200 °F(93°C)= E, 212°F (100°C)=M,286 °F (141 °C)=G,360°F(182°C)=H, 500°F(260°C)=L. For example,sprinkler VK102 with a 1/2"thread, Brass finish and a 155°F (68°C)temperature rating= Part No. 12987AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No.21475M/B(available since 2017). B.Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B(available since 2000) C. Socket Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B*(available since 2006) D.Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool**Part No. 15915(available since 2010.) E. Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/B*(available since 2006) *A W ratchet is required(not available from Viking). **Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool.Ideal for sprinkler cabinets.Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No.01724A(available since 1971) B.Twelve-head capacity: Part No.01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,the heat-sensitive liquid in the glass bulb expands,causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector,forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic®Standard Response Pendent Sprinkler VK102 is available through a network of domestic and international distributors.See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No.F_031414 17.10.05 Rev 17.2 Page 3 of 7 NIKING® MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384..464 Fax:269-8184680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary Ordinary 100 °F(38 °C) Orange 155°F(68 °C) 100 °F(38 °C) Intermediate 175 °F(79 °C) Red Intermediate 150°F(65 °C) Yellow 200 °F(93 °C) 150 °F(65 °C) High 286 °F(141 °C) Extra High 225°F(107°C) 360 °F(182 °C) 300°F(149 °C) Ultra Highs 500°F(260 °C) Mauve 1111112311111 Sprinkler Finishes: Brass, Chrome,White Polyester, Black Polyester, and ENT 465°F(240°C) Corrosion-Resistant Coatings•: White Polyester and Black Polyester in all temperature ratings. ENT in all temperature ex- cept 135 °F(57°C). Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: 155 °F(68 °C)Lt. Brown Wax P ature ratings 212 °F(100 °C)Dk. Brown Waxs 1 286 °F7(1 1)C)Dk. Brown Wa Brown Wax O°F(93 °C)Brown Wax 1 The sprinkler temperature rating is stamped on the deflector. Footnotes 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C), response time may be severely retarded. °The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are com- patible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings.For ENT coated automatic sprinklers,the waterway is coated. s Wax melting point is 170°F(76°C)for 212°F(100°C)and 286°F(141 °C)temperature rated sprinklers. Wrench Flat Protective Sprinkler Cap 21475 • 10896 Standard Sprinkler eSprinkler /B Standard Sprinkler Wrench for Wax Coated Sprinklers 10896W/B Figure 1: Standard Sprinkler Wrenches Form No.F_031414 17.10.05 Rev 17.2 Page 4 of 7 MICROMATIC®STANDARD NIKING® TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings Ml 49058 akin cor com ite for the latest edition of this technical data page www.vikinggroupinc.com Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@v' g p Visit the Viking webs Listings and Approvals' Nominal Overall Length (Refer also to ULd Approvals' Criteria.) Sprinkler Thread Size K-Factor ��'��� Base Part SIN UM mm Number' NPT BSP U.S. metric' Standard Orifice A2,84,B2Y F2,G2Y v - 12987 VK102 1/2" ® 5.6 80.6 2-1/4" 57 Al,B4,B1Y,C5,D3,E6,G6Z�� A2,B4,B2Y F2,G2Y - - 5.6 80.6 2-1/4" 57 Al,84,B1Y,C5,D3,E6,G6Z�� - _ E7 129899VK102 �® 0 - E7 5.6 80.6 2-1/4" 57 - - 10229 VK102 1/2" 5.6 80.6 2-1/4" 57 20229 VK102 v® - - - NOTlCE-Product Below-Lim+te®ability(Contact Local V�D3,E6ff'G6Z v - - 10139 VK102 1/2" ® 5.6 80.6 57 Al,B4,B1Y,C5, - - - 10173 VK102 v® 5.6 80.6 �® Al,84,B1Y,C5,D3,E6,G6Z 101111210133 18020 VK102 ® 15 mm 5.6 80.6 2-1/4" 57 Al,64,B1Y,C5, D3,E6,G6Z A2,64,B2Y F2,G2X F2910 Approved Temperature Ratings A-135"F(57°C), 155°F (68°C), 175°F(79 Approved Finishes °C),200"F (93"C),286°F (141 "C), and 360 Approved Escutcheons °F(182°C) 1 - Brass, Chrome, White Polyester56, and Black X with the Viking Micromatic® Model B-135°F(57°C), 155°F(68°C), 175°F(79 Polyesters'" 2-Brass,Chrome,White Polyester',and Black Polyester6 E_1,E-2,or Recessed Recessed Escutcheon °C- and"F200(141 "C) C) 3-Brass and Chrome Y - Standard surface-mounted escutcheon or the C-286 26 4-Wax-Coated Brass and Wax Over Polyesters Viking Microfast®Model F-1 Adjustable Escutcheon D-500°F(260"Cy or recessed with the Viking Micromatic®Model E-1, E-155"F(68°C),175°F(79'C),200°F(93 5-High Temperature 200°F(93°C)Wax Coating(corm- oE-2r E-3 Recessed hed Escutcheon Z Standard- surface mounted escutcheon or re- 'F 286"F(141 ° ) 360"F(182°C),and 500 sceiling resistant);150"F(65 maximum ambient temperature allowed at Z -ed wita the surface-mounted Vikce Mornted °ModelhEnt F (260°C)' F- 155"F(68°C), 175°F(79"C),200°F(93 6-ENT' °C),286°F(141°C), and 360°F(182"C) 7-Chrome G-155°F(68"C),175"F(79"C), and 200'F (93°C) Footnotes ule. 2 Base part number is shown•For pressure is measured in bar Viking's pr�ureinceeasurred in kPa,divide the metric K factor shown by 10.0. 'Ties t K-factor shoes the is for usewhen Pass 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. °cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. nee time of the Ultra-High temperature rated sprinkler Sprinklers of Ultra-High and atur ratingr are intended rated sprinkler is significantly igni cantly reducedar below 300f enclosures (149 normal the response temperatures above 300°F(149°C).Where the ambient temperature around the Ultra-High may be severely retarded. °CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-0021. 9 MED Certified,Standard EN 12259-1,EC-certificate of conformity 0832-MED-1003 and 0832-MED-100B. 1°MED Certified,RINA Certificate No.MED497705C5. ru LIQ i isting Requirements: The Viking Micromatic®Standard Response Pendent Sprinkler VK102 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light,Ordinary,and Extra Hazard occupancies. sprinklers must be followed. •The sprinkler installation rules contained in NFPA 13 for standard spray pendent e information.Viking sprinklers are to be installed in similar accordance with the latest IMPORTANT:Always refer to Bulletin Form No.F_091699-Care and Handling of Sprinklers.dAlso refer to page F 080614 for nd general care, installation, and maintenance appropriate standards of NFPA, LPCB,APSAD,V alsoon with Viking technical s oof data,the app p the provisions governmental codes,ordinances,and standards,whenever applicable. Form No.F_031414 17.10.05 Rev 17.2 ® Page 5 of 7 TECHNICAL DATAMICROMATIC®STANDARD RESPONSE PN11(ING T SPRINKLER VKE02 K5. Telephone: The Viking Corporation,210 N Industrial Park (KJr.s� p 269-945-9501 Technical Services:877.384- Ve: the VikingDrive,Hastings MI 49058 website for the latest edition of th s technical ax: data page Email:techsvcs@vikingcorp,com g www.vikinggroupinc.com Sprinkler Base Number'Bas' Thread Size Nominal K-Factor Par ®® Overall Length �® FM Approvals' ' VK102 ® Standard Orifice 1111132. VK102 (Refer also to Design Criteria below) 12989 VK102 1111.11111= 5.6 80.6 5.6 80.6 a® Al,B2,C3,D1,E4,Gly,G4Z NOTICE-Product Below- ® Al,B2, 10139 VK102 ®® Limited Availability(Contact Local VikingC3,D1,E4,Gly,G4Z 10173 v 5.6 80.6 Office)VK102 ® ® 18020 ® 5.6 80.6 �® Al,A1B2,C3,D1,E4,G1Y,G4Z VK102 Approved 5.6 80.6 i Al,62,C3,D1,E4,G1 Y,G4Z A - 135 °F Temperature Ratings C). 5 (57 °C), 155 F °C), 175 F Al,B2,C3,D1,Gly 2C) °F 20041 °CF (93 °C), ° 212 °F (100° °C) and 360°F(182°C) B-135F 1 (57 ),a d3°F 155 (93°C),and 212°F(100° )(68°C)' 175°F(79°C),200°F 1 - Brass, Chrome, White Polyester", and C 286°F(141 °C) Black Polyester d Finishes Approved Escutcheons Y Standard surface-mounted -500°F(260°C)5 2-Wax-Coated Brass eon or the Viking mounted escutch- E-155°F (corrosion resistant) 9 Microfast® Model F-1 (68°C), 175°F(79°C 3 High Temperature 200 °F Adjustable Escutcheon or recessed with the (141 °C),360°F(182°C ) 200°F(93°C),286°F Coating(corrosion resistant; (93 °C) Wax Viking ed Escutche ),and 500°F(260°C s bieont tem Model E-1, E-2, or E-3 ) maximum am- Recessed Escutcheon 2001E(93(C�°C)' 155 °F(68 °C) 175°F(79 °C) and 150°F(65 C)ture allowed at the ceiling = Z Standard surtacemounted escutcheon F- G-155°F(68°C 4- F or re- cessed with the Viking Micromatic® 'Base Part number is shown.For s Metric K-factor shown is for use complete part num Footnotes when pressure is measuredrin aVikrWhenurrent price schedule. 2 This table shows the listingssand approvals °Other ble solors owre available on rnd oh the same Approvals at the time of printing.pressure ist measuredman in kPa,divide the metric lapprovals. s 9•Check with the manufacturer for Sprinklers of Ultra-High temperature rating as the standardby 10.0. Where the ambient tem are intended for use inside ovens,dryers,colors. any additional approvals. temperature rated s temperature around the Ultra-High temperature rated sprinkler is or significantly smilarndosures prinkler may be severely retarded. with no 6 FM approved as corrosion reduced below 30mpal operating temperatures above 300'F resistant. F(149°C, (149°C). the response time of the Ultra-High E1LAD2rov111RP ) The Viking Micromatic®Standard Response Pendent Sprinkler VK102 indicated in the FM q � � .... Sheets(includingPs an dpr specificis is FM Data Sheetal2.0 application and installation requirements, referee FM Global Loss Prevention Data Sheets� Approved as standard response Non-Storage e Sheets nData design,ceiling slope and os Prevention minimum andt montanmulto NOTE:The FM installationstain �the latest a 9 pendent sprinkler as re guillo ablnes rs a cin to, but not ton M Loss Prevention Data guidelines may differ from cULus and/or NFPq wable spacin minimum water supply g and deflector distance below the ceiling. IMPORTANT:care,Always refer todBulletin For maintenance information. -Viking critean. edition of Vikin �No.F 091699-Care and Handling of Sprinklers.thepr general sprinklers are to be installed inAlso accordancew th the latest appropriate standards of NFPA,FM Global LP page080614 for Form No.F 031414 17.10.05 codes,ordinances,and standards,whene edr app(licable,imilar organiza- tions, 17.2 Page 6of7 MICROMRESPONSE PNDENT STANDARD NIKING® TECHNICAL DATA SPRINKLER VK102 (K5.6) J Hastings M149058 cor corn v.king p The Viking Corporation,210 N Industrial Park Drive, vikinggroupinc.com 0 www. Telephone:26he Viking Technical Services:877-384-5464 :69 data page Email:techsvcs@ Visit the Viking website for the latest edition of this technical 1111 if tS ,, ' ' 7:' 14'ii: '' . f f 1 . ' . . ''S' ..,.:4 Sprinkler wrench l3655W!B** for recessed pendent sprinklers **A 112" ratchet is required Carefully slide the wrench sideways around (not available from Viking) the protective cap,ensuring engagement with -41111111'' the sprinkler wrench flats Figure 2: Wrench 13655WIB for Recessed Pendent Sprinklers . l • ',# R 4 fi`- ,49; • F. ,4 ' P � .r� 1: Carefully slide the ,"_ 1`"' Step s around the wrench ''''"' ki esideway engage- ment n a e- lit, deflector,ensuring g g ment with the sprinklger wrench flats. f"' Wax Coated Pendent Sprinkler Sprinkler wrench 13577W.113** ff must be used for installing and wax coated sprinklers. Step 2:Carefully press the wrench upward ensure engagement with the sprinkler wrench **A 112" ratchet is required flats. (not available from Viking) 1flats. B Figure 3: Socket Wrench for Wax Coated Sprinklers Form No.F_031414 17.10.05 Rev 17.2 1 ® MICROMATIC®STANDAPageRD7of 7 TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings Ml 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm)minimum (15 mm) 2-1/2"(64 mm)maximum NPT 2-1/8" ,, �, (54 mm) .4" . 4.. .. , , 2-3/16" �' A 1-1/2" (56 mm) 1-3/4" 2" (38 mm) 1 (45 mm) (51 mm) Min. Max. __t___,ppsspsp. Installed with a standard Installed with a Microfast 1/8"surface-mounted Note:At maximum,adapter is escutcheon Model F-1 Adjustable exposed 1/2"(13 mm)from face Escutcheon of ceiling Figure 4: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon ill 11 Ceiling Opening Size: 2-5/16"(59 mm) minimum 2-1/2"(64 mm)maximum 2-1/8" 2-1/8" 44, (54 mm) (54 mm) 1-3/4" 1-1/8" 1-1/8" (45 mm) , (29 mm) 2'", (29 mm) Max. i,• Min. (51 mm) ,, x Min. Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 5: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No.F_031414 17.10.05 Rev 17.2 Replaces Form No.F_031414 Rev 16.2 (Added new standard wrench 21475) Page 1 of 6 ® MIRAGE®STANDARD AND IRKING MIRAGE® DATA OR CONCEALED PENDENT SPRINKLER VK462 AND HP SRIThe Viking Corporation,210 N Industrial Park Drive, HastingsMIl49058 KLER VK463 K5.6 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs vikin c Visit the Viking website for the latest edition of this technical data page. @ g °rp•com 1. DESCRIPTION Viking Mirages Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a lowAlt - profile cover assembly that provides up to 'W (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate.The"push-on","thread-off'design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of w #r service or removing the sprinkler.The Electroless Nickel PTFE(ENT)coating has been investigated for installation in corrosive atmospheres and is cULus Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly,the cover plate is not plated. 2. LISTINGS AND APPROVALS c o� us cULus Listed: Category VNIV inl ^ FM Approval: Class 2015 Fits NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 " `' LPCB Approved: Ref. No.096e/12 CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Qr' CCCF Approved:Approved by the China Certification Center for Fire Products(CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi(0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working 7 psi (0.5 bar) up to 250 psi (17.2 bar)for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating"250"stamped on the deflector.Sprinkler VK462 is rated to a maximum 175 psi(12 bar)nwwp from the minimum Factory tested hydrostatically to 500 psi(34.5 bar) Thread size: 1/2"(15 mm)NPT Nominal K-Factor:5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to-65°F(-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE ApprovalsLONLY is 5 psi Approval, (0.35bar). 1-Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly:Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter:Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No.F_103005 17.02.02 Rev 17.1 Replaces Form No.F_103005 Rev 16.1 (Added PNs for CCCF Approved sprinkler) • Page 2of6 MIRAGE®STANDARD AND QR CONCEALED PENDENT TECHNICAL DATA SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 vlkin corp.com Telephone:269-945-9501 Technical Services fort 877484-5464 8e-546est edition Fax: 26f 9 18 1 8 al data pagechSVcs@ 1 9 p Visit the Viking website Cover Assembly MMaterials: C11000 Cover:Copp Base:Brass UNS-C26000 or UNS-C26800 Springs:Nickel Alloy Solder: Eutectic Ordering Information:(Also refer to the current Viking price list.) or Brass finish and 13503JN for ENT finish.VK463-HP base part No. 13667A Viking Mirage®Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: o e Specify sprinkler: Base Part No.VK ra 1350A addingthe appropriate suffix for the temperature rang ber: Te petoreSui : 155°temperature rating by175 (79°C)=D,200°F (93°C)=E Temperature Suffix: 155°F (68°C)= 13667A6. For example,sprinkler VK463 with a 155°F (68°C)temperature rating= Cover Plate Assembly:Base Part No. 13504(2-3/4"diameter),Base Part No.13642(3-5/16"diameter), f the finish or se Part and h.15394 Co the appropriate suffix cover (square coverand plate,3ratu a diameter) Specify finish temperature rating of the cover plate assembly by adding Antique Brass = B-/A, Brushed Brass = B-/B,temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, q er=E-IB,Painted White=M-/W,Painted Ivory=M-/I,Painted Black=M-/B Brushed CoppUL(139°F(59°C)FM and LPCB)=A, 165°F (74°C)=C (74°C)temperature rating= 13504FC. TemperatureaSuffix:ve135°F(57°C) Chart. temperature rated cover plate only.Refer to the Approval For example,cover 13504 with a Polished Chrome finish and a 165°F Note:Square cover plate 15394 cULus Listing is for the 135°F(57°C) Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B(available since 2006),or B.Head Cabinet Wrench Part No. 14031***(available since 2006) C.Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the ets large diameter cover (available since 2007) **Requires a'/2"ratchet(not available from Viking).***Optional for removal of the protective cap.Ideal for sprinkler Sprinkler Cabinet Part No.01731A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION approaches its operating temperature,the cover plate detaches. Continuedan fire heating ns,when the edtemperaturesprinkler causes the heasprip ser Water flowing through the sprinkler orifice strikes the sprinkler deflector, heating of the exposed causes heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY V9 P ikin S rinklers VK462 and VK463 are available throughThea net workCoof pdomes is and international distributors. See The Viking Corporation web site for the closest distributor or contact 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No.F 103005 17.02.02 Rev 17.1 k y Page 3 of 6 ® MIRAGE®STANDARD AND TECHNICAL DATA OR CONCEALED PENDENT SPRINKLER VK462 AND HP The Viking Corporation,210 N Industrial Park Drive, HastingsMI 4 058 RINKLER VK463 K5.6 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvc Visit the Viking website for the latest edition of this technical data page. s@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155°F(68°C) 100°F(38 °C) 135°F(57°C)cULus Intermediate 175°F(79 °C) 150°F(65 °C) 139 F(59 C FM and LPCB Red Intermediate 200°F(93°C 165 °F(74 °C) Coverr Plate Finishes:Polished Chrome,Brushed Chrome,Bright Brass,Ant quo Brass,Brushed Brass,Brushed Copper,Painted Yellow or Painted Black5 °C 165°F 74 °C Sprinkler Finishes:Brass and ENT PP White,Painted Ivory, Corrosion Resistant Coatings':ENT 'The sprinkler temperature rating is stamped on the sprinkler deflectoFootnotes 2 ed on NFific 13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Refersto specific installation standards. 'The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval tests cannot and do not represent all possible corrosive environments. Prior to installation,verify Having Jurisdiction. t with , suitable the proposed environment. For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces, lewaterwawitbut, the for the •rin. is exNosed. tared to the end-user xter thrfess nclre ding th ces,including th Sprinkler Mill Nominal Maximum Base Part No.' ®®®actor Water Working Listingsalsand Approvals' Pressure (Refer Design Criteria) 13503A 1/2° Standard Response Applications �0 �® 1/2° v 5.6 80.6 175 psi(12 bar) ® mai 80.6 175 psi(12 bar) v�v - ® 5.6 80.6 175 psi(12 bar) vv v 13503A ®®® Quick Response Applications vvv� 13503JA 80.6 175 psi(12 bar) �� 1/2° ®m 80.6 175 psi(12 bar) aa� VK463 ®® 5.6 80.6 250 psi 17.2 bar)3 ®nava Cover Plate Assembly Temperature Ratings'®vvvv Sprinkler Temperature Ratings V 135°F(57°C)cULus Listed cover 13504', 13642'(large diam- A-155°F(68°C) eter),or 15394'(square cover plate) Cover Plate Assembly Finishes" B-175°F(79°C)and 200°F(93°C) W 165°F(74°C)cover 13504'or 13642'(large diameter) 1- Polished Chrome,Brushed Chrome,Bright Brass, B C.200°F(93°C) x-165°F(74°C)cover 13504',or 13642'(large diameter) AntiqueaiteBrass,PaintednIvory,Brass, ai teed ac Y-135°F(57°C)cover 13504'LPCB Approved as 139°F(59°C Painted White, or Painted Black CopPer Z-165°F(74°C)cover 13504' Footnotes 2 Brass 'Part number shown is the base part number.For complete part number,refer to current Viking 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown The Water Working Pressure rating is stamped on the deflector. price list schedule. This chart shows the listings and approvals available at the time of printing.Other approvals may be in process. Check with the manufacturer for approvals. by 10.0. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. 'Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.32. any additional 'VdS Approved,standards VdS 2344:2005-12,VdS 2100-25:2008-01,and EN 12259-1:1999+A1:2001 + 8 CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2032. 9 The 135/139°F cover has an orange label.The 165°F(74°C)cover has a white label. A2:2004+A3.2006,Certificate G4080021. "Painted finish consists of Polyester Baked Enamel.Other paint colors are available on request with the same listings as the standardaint approvals apply for any paint manufacturer.Contact Viking for additional information. 11 cULus Listed as corrosion resistant. NOTE:Custom colors are indicated on a label inside the cover assembl .Refer to Fi.ure 1. P colors.Listings and Form No.F_103005 17.02.02 Rev 17.1 t f Page 4 of 6 -I--.--------.m••••N1KjING MIRAGE® STANDARD AND ® OR CONCEALED PENDENT TECHNICAL DATA SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 vlkin Cor Com 269-945-9501 Technical Services: 877384-5464 eFan:2f69- technical data pagechsvcs@ 9 p' Telephone: Visit the Viking website for th r g t Mine aledlPendent rements: inklers 462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of Mirage® for standard Peove coverage pendent spray sprinklers as indicated below. NFPA 13 standard Covera a • For hazard occupancies up to and including Ordinary Hazard,Group II. NFPA 13. • MProtection areas and maximum spacing shall be in accordancie with the talled in ables provided inh NFPA 13.Maximum spacing allowed is 15 ft.(4.6m). • Minimum spacing allowed is 6 ft.(1.8 m)unless baffles • Minimum distance from is 4 (102mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between rdistance shall be measured perpendicular to the wall. •The sprinkler obstruction rules contained sprinklers must be followed. NOTE:Concealed pnklsprinklers must be installed in neutral or negative pressure plenums only. YaS Aoo The ssprinkler can a ins te ceiling massive ceiling)or in a false ceiling made of light materials. a) can be installed in a type andconcrcanbe only activated by heat.The housing is not tight. b c)Thislsprinkler isti n guidelinesector fixed ace andisOH protectedccbya a n y be alled n c)Follow installation of current standards,CEA4001VdS and EN12845.These sprink'nrwh ch thle false ceiling ng isP H OH occupa - cies,except in OH4. type'Domed CCP'shall not be installed in false ceilings NOTES: Due to the design the sprinkler water extinguishing system. the design the sprinkler type Domed-CCP' shall tnonot fbe ilse nstalled in in false ceilings in which during a fire the pressure above the false ceiling mayDue to 9 The ri assumed to ber higherthan thetco pressure for this approval is heat. The criterion for the dropping Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. Sprinklers.Also refer to Bulletin 4. Replace the plastic cover and do not remove until the cover is installed. of Always refer to Bulletin Form No.F_091699 -Care and Handlingsprinklers rs are toB 11 in IMPORTANT: 8061 Vik standardssprods ofrs NFPA, b in- stalledtechnical data,the appropriate Form No. F 080614 for general cest�editionlaof Viking maintenance information. Viking codes,ordinances,and in accordancehwith the latest APSAD,VdS or other similar organizations,and also with the provisions ofg standards,whenever applicable. Q\'\�p CUS TCS t:•-) n 4. O vIKING• All custom color painted cover plates will have an identifying label affixed to the inside of the cover that 3-5116" (84 mm) indicates the custom color and will have a representative sample(a paint dot)of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly 15394 Form No.F_103005 17.02.02 Rev 17.1 NI!IOWA ® Page 5 of 6 STATECHNICAL DATA R1 CONCEALED AND SPRINKLER VED PENDENT Telephone: The Viking K462 AND M 269-945-9501 TechnicalgServices:Corporation,210 N Industrial PSPRINKLER HP 8 Visit the an rvices:877-384.5464 Fax:aft Drive, 1lastin VK463inor .6 Viking website for the latest edition of this technical data Pa e. -818"1680 Email:techsvcs Page. @vikingcorp,com Sprinkler Base Part No.' ` ® Nominal K-Factor Maximum 13503A ®®®® Water Working ®® •� Pressure (Refer FM Approvals, 80.6 175 also to Design Criteria Sprinkler Naliam Plate Psi(12 bar) below.) Ratings B 175°F(68°C) w- 139 Cover AssemblyeTemperature Ratings �r F(79 erTemperatureed 2u °F °C) or 9°F(59°C)(square cover 135041, 136421(large diameter Cover Plate Assembly. 74 Plate) ) 1 -Polished Finishes' A-155 X 163 165 F( °C)cover 135041,13 , Chrome,Paintededd Chrome, 94 (square cover 642 (large diameter),or Brass, Antique Brass, Bright plate) vorBruy,or aiBrushed 'Part shown is the base Copper, Brass, part number.ForFootnotes IYOry or Painted Black White, Painted 2 Mart numbermeasurement complete shown is whenPart number,r 'This chart shows the FM Approvals pressure is refer to current Viking approvals. K-factorls. swn is when e athe time of printing. Bar.When price st schedule. pressure iy b measured process. in .kPa,Check divide the metric °The 139°F(59°C) 9 Other approvals cover has an orange label. may be in Process. with the K factor shown s Painted finish consists of Polyester Baked The 165° by 10.0. ListingsF(74°C manufacturer for and approvals applyEnamel. )COVer has a white label. any additions NOTE:Custom for anyOther paint colors colors paint manufacturer.Contact Viking for additional information. are indicated on a label available n request with the same listings as the standard assembly.Refer to Figure 1. paint colors. EM-BPProval eO,i Viking Concealed Pendent Sprinkler VK462 is FM Approved Approval Guide.For specific application and installation r ket 2-0). FM Global Loss Prevention as a standard res o,cuslope pd tData response Non-Storage e Sheets requirements,reference the latest applicableg Concealed NOTE: obsrn mi S and contain guidelines mtedFMpendenttersprinkler supply r as indicated The FM installation peand maximumrelating to, but not ctorted to: below Prevention Data Sheetsin the FM Sh guidelines may differ fromallowable spacing, end deflector distanceminimum (including desig IMPORTANT: cULus and/or NFPA criteria. the tceiinrequirements, hydraulic Data RTANT Always refer to SR1-3 for general care, Bulletin IMPinstallation, Form No. F 091699 - with the latest edition of Viking maintenance informateion. and Handling of Sprinklers.Also refer to page standards, organizations, data, the appropriate standards lers ofare to be installed in ac- cordancewheneher similarorg ,and also with the provisions of governmental codes,FPA, M Global' �pC6, ordinances,and Form No. F 103005 17.02.02 Rev 17.1 1 Page 6of6 MIRAGE® STANDARD AND 4R CONCEAL CD462 AND HP VIKING® TECHNICAL DATA SPRINKLER V SPRINKLER VMC463 K5.6 Corporation,210 N Industrial Park Drive,Hastings Ml 49058 vikingcorp.com The Viking 7-384-5464 Fax:269:818-1680 al data page.hsvcs@ 2-114" (57 Telephone: Visit the Viking website for the latest edition of this diameter opening hone:269 945-9501 Technical Services: required in mm)e Sprinkler and AI ceiling. Adapter Assembly Sprinkler Wrench . Protective cap *< Part No.14047W1B** ..„,aw removed .� �, , • Use wrenchPt _ r s,a „ ,,..,,,..._ 14047WIB** v - ;1. t t ward and Step 2: Carefullypress the wrench a ement with the deflf turn slightly to ensure eng 9 Step 1 the sprinklyr wrench flets. eslide the Carefully wrench sideways around the dector and pins Sprinkler the installation wrench flat Sprinkler sprinkler by applyingOT instaghten. frame arms NEVER install the the arms, DO N wrench across frame rinkler wrenchesViking se Use Numbers the designated sp *. A.leak tight , ** or 14031 �..� turning the sprinkler clockwise Part ever b IB should-b2 turns beyond finger tight. 1 t per Wrench Usage Figure 3: P (Not available from Viking) �s f 44 Sprinkler Installation and Prop ** A112”ratchet is required 2-1116" (52 mm) (15 mm)NPT 2-9116" (65 mm) Minimum 112" \ Maximum � --.0•0.------ 20 r 3lfil+" s 2-314" (70 mm) or �.. - (84 mm) i ...v - 3-5116 sprinkler activation,the deflectornk�►body to approximately Upon sp 13/16"(21 mm)below the sp roximately Cover Installation F_103005 Rev 15.1 app Sprinkler Dimensions and No. Figure 4: p Replaces Formupgraded graphics) Form No.F_103005 17.02.02 Rev 17.1 (Added PNs for CCCF Approved sprinklers;rs; Page 1 of 10 NIKING® TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION Viking sprinkler escutcheons are ornamental plates used with 3/8"NPT(10 mm BSP)*, %" NPT(15 mm BSP)*, and '/%" NPT(20 mm BSP)*frame-style pendent and sidewall*sprinklers.The escutcheons are installed between the sprinklers and the ceiling or wall for a pleasing appearance.They are available with several finish options to meet design requirements. Viking recessed and adjustable escutcheons provide a low-profile decorative recessed sprinkler installation.The E-1 Recessed Escutcheon may be recessed up to 5/8" (16 mm). The Model G-1 Recessed Escutcheon allows horizontal sidewall sprinklers to be recessed up to 1/2"(13 mm).The Model F-1 Adjustable Escutcheon has%"(13 mm)total adjustment available. The two-piece design of Viking's recessed and adjustable escutcheons allows in- stallation and testing of the sprinklers prior to installing the ceiling or wall.Viking's Model E-1, F-1, and G-1 Escutcheons feature a slip-on design, while the Model , f E-2 and E-3 escutcheons are threaded(outer cup threads onto the adapter). The Viking adjustable and recessed escutcheons are made to allow for minor E-2 Escutcheon adjustments due to pipe or ceiling pitch.These escutcheons can be removed and reinstalled,allowing access above removable ceiling panels for servicing building } equipment without shutting down the sprinkler system and removing the sprinkler. Viking standard 1/8"(3 mm)style flat and 1"(25 mm)style raised surface-mount- ed escutcheons have a one-piece design. *Refer to the specific sprinkler technical data page for the escutcheon(s) listed and approved for use with the sprinkler. E-3 Escutcheon 2. LISTINGS AND APPROVALS al. Refer to the specific sprinkler technical data pages for sprinkler listings and ap- provals. Sprinklers must be specifically listed and/or approved for recessed in- stallation.When using Viking Model E-1, E-2, E-3, F-1,and G-1 escutcheons for recessed applications,refer to technical data describing the sprinkler model to be used to verify whether the sprinkler is listed and/or approved for recessed installa- tions. NOTE:Viking's thread-on style Model E-2 and E-3 Recessed Escutcheons F-1 Escutcheon carry the same listings and approvals as the slip-on style Model E-1 Recessed Escutcheons. Model E-3 Recessed Escutcheon also meets IBC-ASCE/SEI 7 Codes for Seismic Areas C, D,and E. Raised Surface Mount Escutcheon / '.--,.... -°' IIM G-1 Escutcheon Expansion Pl. - Flat Surface Mount Escutcheon Form No.F_122698 17.02.02 Rev. 17.1 Replaces page 135a-i dated (Removed 13220,06420A and 06912A and added 20123,20369 la and 20371) � . 4 Page 2 of 10 NEKING® TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive, Hastings Ml 49058 wkin corp.com Telephone:269-945-9501 Technical Webs to for the Bates 6edition of thist 1680 al data page.cs@ ' 9 Visit the Viking 3. TECHNICAL DATA Specifications: A.Slip-on Style Model E-1 Recessed Escutcheons Depth of Outer Cup: 1-1/16"(27 mm) Outside Diameter of Outer Cup:3-1/16"(78 mm) Depth of Center Adapter Ring: 11/32"(9 mm)+/-1132"(1 mm) Adjustment Range:Flush to 5/8"(16 mm)recessed NOTE: Escutcheon adapter is stamped"Viking Model E-1". Available since 1987. B.Threaded Style Model E-2 Recessed Escutcheons Depth of Outer Cup: 13/16" (21 mm) Outside Diameter of Outer Cup: 3-1/8" (80 mm) Depth of Center Adapter Ring: 21/32" (17 mm) Adjustment Range: 27/32" (21 mm)total adjustmentwith /" (13 3 mm)maximum recess available.NOTE: Face of escutcheon cu adapter may extend up to 11/32"(9 mm)beyondg e Available since 2000. C.Threaded Style Model E-3 Recessed Escutcheons Depth of Outer Cup: 13/16"(21 mm) (130 mm). (See Figure 4) Outside Diameter of Outer Cup: 5-1/8" Depth of Center Adapter Ring:21/32"(17 mm) Adjustment Range: 27/32" (22 mm)total adjustment with of esch W' peon axmaximum recess available. Note: Face of escutcheon adapter may extend up to 11/32"(9 mm)beyond Available since 2012. D.Model F-1 Adjustable Escutcheons Depth of Outer Cup: 1-1116"(27 mm) "(78 mm) Outside Diameter of Outer Cup:3-1/16mm) Depth of Center Adapter Ring:23tot I(18d'ustment with '/:' (6 mm) maximum recess available. Note: The face of escutcheon Adjustmentadr Range: W up (13 mm) 1 adapter may extend uto'/<"(6 mm)beyond the edge of the escutcheon cup. NOTE:Escutcheon adapter is stamped"Viking Model F-1". Available since 1988. E.Slip-on Style Model G 1-1/16"(27es edmEscutcheons(US Patent No.8,376,060) Depth of Outer Cup: 4" ) mm) Outside Diameter of Outer Cup: (102(37 mm) to 8/12 (33.7°). May be re- cessedDepth of Center Adapter Ring: totalmadjustment available for use with ceilings sloped up extend up to 1/2"(13 Adjustment up to (13Umm),to 5/8" (16 dinmm to'/:" depending on degree of slope.NOTE:The face of escutcheon adapter may mm)beyond the edge of the escutcheon"Viking h up. Model G-1". NOTE:Escutcheon adapter is stamped Available since 2007. F.Expansion Plate(optional) 1. Base Part No. 12620 for useand flat plate concealed sprinklers. May also be used with dry recessed sprinklers, dry standard adjustable sprinklers, Outside Diameter:5" (127 mm) Inside Diameter:2-3/16" (56 mm) Available since 2005. 2. Base Part No. 13128 for use with Domed Concealed Sprinklers. Outside Diameter:5"(127 mm) Inside Diameter:2-15/32" (63 mm)for Part No. 13128. Available since 2005. VK636. 3.Base Part No. 16340 for usewith ConcealedeSprinkler Outside Diameter:5-5/1 (135 mm Inside Diameter:2-3/8"(61 m) Available since 2010. Form No.F_122698 17.02.02 Rev.17.1 M i ® Page 3 of 10 VIKING TECHNICAL DATA SPRINKLER ESCUTCHEONS Telephone: The Viking Cor 269-945-9501 Viking Conical Services:270 N Industrial Park Drive, 49058 Visit theTki877-384-5464 Fax: riv8,Hastings echs Viking website for the latest edition of this technical G.Standard Flat andEmail:techsvcs@vikingcorp.com of this data @vikingcorp,c°m Surface-Mounted Escutcheons page. Depth of Escutcheons: Flat: 1/8"(3 mm Available since 1972 Material Standards: ) Raised: 1"(25 mm) A. Slip-on Style Model E-1 Cold nllSt Style eel Mdel Recessed Escutcheons: B. Threaded StyleG10080 or Stainless Steel UNS- Escutcheons; Model E-2 and E-3 Recessed 530400 C. Model 24 ga.(1 mm)thick 1010-1018 mild steel elG-1 Recessed c nEsscutcheons and Model F-1 D. Adjustablexpnsin Escutcheons:te(optional): Rolled Steel UN EStandard pio and tonal): Cold Rolled Steel U S 6100 Flat Style Part FlataRaised Surface-Mounted Escutcheons: Flat Style PartNumbers 01960A, 01015A, Escutcheons: ty Numbers 00196 02960A, and 05464 *These may also e special07526,and 09596*:Stainless Steel ColdRolledSteel U Raised Style ordered and manufactured from Brass NS-S43000 NS-G10080. or USPart Numbers 019618 026800. and 01016A:Brass U (nonmagnetic material).Contact the manufacturer for more information. Information: NS-026000 Orderingrin mation:(Also refer to the escutcheonsby and adjustable escutcheons are st Viking Y adding the price list.) appropriate suffix for the finish to the be as se escutcheon A.Model F- packages(includes outer cup and adapter). 1 Adjustable and part number. pter. outer cup and adapter), Model E-1, ) Order Viking specify thea E-2,E-3,and G-1 Recessed Escutcheons: appropriate package part number from Table 1. To order as an escutcheon B. Standard Flat and Surface-Mounted Suffix:Bright Mounted package(includes For example, Flat the Model RaisedE- Surface Chrome Escutcheons: S is also available in Antique Bras Specify the flat or raised escutcheon Recessed Escutcheon for Polyester- finixaes. M'�andfiBlack Pot part number from NPT sprinkler, Brass finish=Part No. =M-/B. Table 1. NOTE:Recessed Escutcheons are not included a sod and s, Brushed Copper Brushed Chrome, and Brushed me, AB The 1/2"Model E-1 4. INSTALLATION must be ordered se Brass as standard A. If theproposedParately, allation element, sometA thorit�esf Model Hav Having AuthorityheE-2, E-3, F-1,or G-1 Having Jurisdictiong Jurisdiction Escutcheons re hazard. prior to installation. may limit the use, requires recessingeany of the heat-sensitive operat- ing B. andAll escutcheonRe styles to are AuthorityThe priorrio of depending on the occupancy Having Jurisdiction. quick response sprinklers obe classification. cymust be attached to the s made to thread onto the sprinkler head may also Refer to the to installation. withsprinkler limited due to occupancy capsprior to applying pipe-joint prior to installing the sprinklerhe into the fitting. with protectiveheectiappropriate or sprinklerb shields s must technical datacompoundapor PTFE tape The escuor tae . accordingpage for additional warnings to the sprinkler threads.NOTE:Sprinklers D. Model F- to the followingcaps or shields before applying 1 Adjustable and Model E_ sequence. Y 9 Pipe joint compound escu (Refer to Figures 2-5.) 9 and installation instructions or tape, Step 1: Install all i 2, E-3,and G-1 Recessed and then install the piping and Escutcheons: a minimum 2-5/16"g cut the sprinkler nipple so that the reducingons, 2-1/2" coupling is at the desired location to 4-1/2" 115m mm) diameter opening in the and centered in Step 2:Secure the escutcheon ( m) for Model E-3, or 2-5/8" (66 ceiling or wall for face of the adapteradapter onto the mm) to 3-3/4 Model E-1, E-2, or Step 3:Apply utcheo rest on r o s sprinkler by hand turningthe (95 mm) r Model G-1 h a l shout of shoulder of the s adapter clockwise allow abuild-up of compound pipe-joint co sprinkler wrench boss, onto the sprinkler within ee pound ip the sprinkler mpound or PTFE tape to the external threads of the sprinkler threads.cThe caps or shields before pip-joi NOTE:S applying Pipe jet. compound with protective capslhieonly,taking pound or tape, or bulb shields care not to must be contained Form No. F_122698 17.02.02 Rev. 17.1 M Page 4 of 10 ® DATA SPRINKLER ESCUTCHEONS TECHNICAL Hastings MI 49058 vikingcorP•COm oration,210 N Industrial Pak Drive,H 80 Email techsvcs@vikingcorp.com Viking Corp -384-5464 Fax: e. le hone:269-945-Vis t theTechnicalViking Services:877 care not to over-tightenthread Te website for the latest edition of this technical data pagaking P Visit the special recessed sprinkler wrench only, sprinkler deflector,or fusible element to start or sprinkler into the coupling using new thread 4:Install the sp operating parts.DO NOT use the escutcheon, P normally the unit must removed,the sealing damage the sprinkler occurs, joint beeal leaks, the sprinkler into a fitting• aired and repair all leaks.If a thread leak when system as req applied, finish work completed Test the tape and then reinstalled.This is due to the fact a"or ceiling sprinkler opei rat- ing 5: ound or PTFE PP Dint. damage to the p pipe- joint comp tape isi washed out of lin) s and bulb shields AFTER the are snapkes together. compound sprinkler protectivealland t sprinkler caps longer is a potential for mechanical where gy CAPS AND Step Remove Plastic rinktheY SPRINKLER wh6:ere the simhe pull the ends n th ull them off the sp is installed and there no long s slightly and p s rinklers,turn the cap BEFORE PLACING THE SYSTEM SERVICE! Retain a To BULB SHIELDS.To remove e shields, SPRINKLERS IN the SERVICE! style I escutch- eon a- remove caps from frame style p MUSTBE REMOVEDkler netOM opening size,press on or thread on(dependsexpansion in the spare required or`mall' eon the protective cap the ceiling or wall with the flanges touch the surface of the ceiling The Hang Stepe 7: user)the outerg until the first slide it onto the escutcheonngrall. eon used)the escutcheon cup plate is used, mm). (NOTE:If the optional escutcheon expansionor wall,) adapter recess is 518" (1613 mm). Note:The face of resulting in 27/32" (21 mm)total plate should touch the Model E-1 a the ecditing thed maximum recess iis+2 With the slip-on styledstyle Model Recessed Recessed,the bey rid edge of escutcheonmcup, extend Withto 11132"(9 m ) adapter may With the threaded E-2extend E-3d Recessed Escutcheons, The face of the escutcheon the escutcheon Adjustable d u tar may Note: +, (6 mm). total adjustment range• adjustment range• the maximum recess is1/4" in+h" (13 mm) 13 mm). W adj beyondtale Escutcheon, the edge of the escutcheon the maximum adapter recess is 1/2" With the Model F-1 Adj up to+ i slip-on mm) 1 Recessed Escutcheon, as apterred. DOh the if styletiModel aGre-cut the sprinkler drop nipplecentered in a DO NOT modify the unit.If necessary, coupling is at the desired location and sprinkler nipple so that the reducing sprinkler threads. (The E.Standard Flat and Raisedria cut the sAp anted Escutcheons:n the ceiling or wall. Step 2: Install a piping diameter tethe sprinkler hand turning the escutcheon clockwise onto the care not e maximum 2- 112" (64 mm) bysprinkler.) sprinkler taking Step n excur f the of the sc t ontoo compound or PTFE tape to the the sprint l .) of the Sprinklers external protecve threads apse bulb seonly,musti be contained not to convex surface the escut tcheon f a�e s nt comp ust face toward thTEeSP int of _• be nt Step 3:Apply a small amounound n the sprinkler inlet.NO ound or tape• taking care not to over tig dam of comp l m l e joint comp or tap wrench only, allow abuild-up the special sP or ingicable elnot to to start or thread t - or shields before app Y g p p within the capscouplingusing sprinkler deflector, 4: Install the sprinkler into the complywith the installation Step operating parts.DO NOT use the escutcheon, P age the sprinkler The test must be conducted eounimustrbe removed, new systeme must be tested. cormally seal leahe the sealing sprinkler into a fitting the entire sprinkler tightened. If a thread leak occurs, Step p:Mer installation, ie is nd then oThis is due to the fact that when the jointfeted standards.Make sure the sprinkler applied,and then reinstalled. finish work is comp compound or tapePP joint. a to the sprinkler operat- ingpipe-jRint compcaps and bulb shields AFTER the wall or ceiling ed together. d compound or tape is washed out of the are snapp plastic is installedve sprinklerlonger is a potential for mechaani al damage CAPS AND Step Remove there simplyno theY SPRINKLER esnaped wh6:ere the sprinkler is and pull the ends of the thems off the sprinklers. IN SERVICE! Retain a Tosprinklers,turn the caps slightly and pullPLACING THE SYSTEM To L SHIELDS. remove thee bulb p shields, remove caps from frame sty MUST BE REMOVED cabinet. SPRINKLERS BEFORE as ired. BULB ivecin the spare sprinkler ca sprinkler drop nipple protective me cap re-cut the DO NOT modify the unit.If necessary, Form No.F_122698 17.02.02 Rev.17.1 Page 5 of 10 NIKING 8 TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings Ml 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-8184680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. F. Disassembly: The outer cups of Viking adjustable and recessed escutcheons can be removed and reinstalled without removing the sprinklers to allow access above the ceiling or to replace it, if necessary. 1. For slip-on style Model E-1 or G-1 Recessed Escutcheons and Model F-1 Adjustable Escutcheons, remove the outer cup simply by pulling it outward and away from the wall or ceiling. 2. To remove the outer cup of the threaded style Model E-2 and E-3 Recessed Escutcheons, turn it counterclockwise to un- thread it from the adapter. If it is necessary to remove the entire unit, the system must be removed from service. Refer to maintenance instructions on the appropriate sprinkler technical data page and follow all warnings and instructions. 5. OPERATION Refer to the sprinkler technical data page for the sprinkler model used. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY Viking sprinklers and escutcheons are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_122698 17.02.02 Rev. 17.1 I w Page 6 of 10 NIKING TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings Ml 49058 Telephone:269-945-9501 Technical Services: for the 877-384-5464 4 54 edit edition of this Fax: 1680 Eal data page cs@vikingcorp.com Visit the Vikingwebsite Sprinkler Thread Size Available Finishes Outside Diameter Base Part Number Standard Flat and Raised Surface-Mounted Escutcheons 01960A 11110311111111101111111111 1122=12211 3-5/16"(84 mm) 09488 3/4"(20 mm) 01015A 2-3/4"(70 mm) 02960A 2-3/4"(70 mm) 2-3/4"(70 mm) 07526 3/4"(20 mm) 05464A 3/4"(20 mm) 09596 11111111113131111111111 2-3/4"(70 mm) Raised 01961B016MEM3/4"(20 mm) Raised 01016A - (includes adapter and outer cup) E-1 Slip-on Style Recessed Escutcheon Packages0 mm) 1111113011111111103111 Recessed Slip-on 06419A 1111031111 Recessed Slip-on IMENCEINIMilleMEM 07902 EM=11 Recessed Slip-on 20123 Recessed Slip-on 3/4"(20 mm) 11111111131111331=11-_ 20369 Recessed Slip-on 3/4"(20 mm) E-2 Threaded Style Recessed Escutcheon Packages(includes adapter and outer cup) 1103811110:3111Recessed Threaded INNEIME111111 MECO Recessed Threaded 3/4"(20 mm) . E-3 Threaded Style Recessed Escutcheon Packages(includes adapter and outer cup)INIEEMINIIMMIN 5.118"(13omm) Recessed Threaded 5-1/8"(130mm) Recessed Threaded 3/4"(20 mm) F-1 Adjustable Escutcheon Packages(includes adapter and outer cup) 06911A MEM Adjustable allinarailli - 20371 11111011111 Adjustable 3/4"(20 mm) G-1 Recessed Escutcheon Package(includes adapter and outer cup) 4"(102 mm) Recessed Slip-on 4"(102 mm) EMENI Recessed Slip-on 3/4"(20 mm) - Optional Expansion Plates Available Separatelya � M/B MISW1641, E-1,E-2 Recessed 3/8", 1/2",&3/4" B/B F/B EIB OM 12620 &F-1 Adjustable (10,15,&20 mm) Domed Concealed 1/2"&3/4"(15&20 mm) ME Concealed(for 3/4"(20 mm) 16340 Sprinkler VK636) ess kel PTFE,M/ Escutcheon Finishes:B=BiF=Poli sChrome, / White tyM/B=Black Polyester,JN= Brushed tlc aW16oNavajo WhitePaint,B/A=Antique Bras , = hBrass, IBrushedChrome,E/B= CoperNote:Other colors are available n request with the same listings and approvals as the standard colors.See Sherwin-WilliamColor pInterioCo rSelectionAn color chart. ttEscutcheons 09488,07526,and 09596 may also be special ordered and manufactured from Brass(non-magnetic material).Contact the manufac- turer for more details. Table 1 Form No.F_122698 17.02.02 Rev.17.1 r Page 7 of 10 NilaNG 8 TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. IPer the current edition of NFPA 13: "Escutcheons used with recessed,flush-type,RTANT NOTES assembly."The Viking Corporation will not authorize the sale of unlisted recessed sprinkler assemblies nor assume any liability involving recessed sprinkler assemblies that are not considered cULus Listed,FM Approved,or concealed sprinklers shall be part of a listed sprinkler Listins and approvals vary,depending on the sprinkler model,temperature rating,ifinish,full nd occupancy classification.lrequirements". L\-"J'''',:i0";.4 Viking products are manufactured and tested to meet the rigid requirements of the a signed to be installed in accordance with recognized installation standards.Deviation from the standards or any alteration to the sprinkler after it leaves the factory including,but not limited to:painting approving agency.The sprinklers are de- will nullify the approval and anyThe 9 plating,rpoacoating,or modification,may render the sprinkler inoperative guarantee made by Viking Corporation, and IMPORTANT:Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers.Also refer to the ap- propriate sprinkler data page.Viking sprinklers are designed to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global, LPCB,APSAD, VdS or other similar organiza- tions,and also with the provisions of governmental codes, ordinances, and standards whenever applicable.The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Depth: Adjustable 11/32"(9 mm) +/-1/32"(1 mm) Adapter Ring A s �� �; u. 1 -----f-- „ 0 Ceiling/Wall Opening: Maximum Recess: 2-5/16"(59 mm)Minimum 5/8"(16 mm) 2-1/2"(64 mm)Maximum 2-1/8" Adjustable (54 mm) Outer Cup 1-1/16" i; h (27 mm) .� 1/8,. 31/16 `(( ,r.,ii_____ (3 mm) (78 mm) k aximum Extension: Flush,0"(Omm) Figure 2: Installation of a Slip-on Style Model E-1 Recessed Escutcheon with 5/8"(16 mm)Maximum Recess. Form No.F_122698 17.02.02 Rev. 17.1 0 s Page 8 of 10 NIKING4 ..® TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:website for the 84-5464 Fax:edition 6f981his -1680 Email: al data pagers@vikingcorp.com Visit the Viking Depth: 21132" ill Threaded Adjustable (17mm) Adapter Ring I Maximum { li 11 Recess: f 112" '"" Ceiling/Wall Opening: 2-5116"(69 mm)Minimum (13mm) 2-112" (64 mm)Maximum Threaded Adjustable 2-118" Outer Cup (54 mm) 1+ "s ''''i*Ill 13116" '3, r. (21 mm) Maximum 3-118"9mm) Extension: 3132" (7mm11132" (2mm) (9mm) Figure 3: Installation of a Thread-on Style Model E-2 Recessed Escutcheon with 27132"(21 mm)Total Adjustment. Model E-3 Recessed Escutcheon meets IBC-ASCEISEI 7 Codes for Seismic Areas C, D, and E Allows 1"(25 mm) Depth: Annular Space for 21132" Seismic Threaded Adjustable (17Applications } Adapter Ring � , Maximum Recess: Ceiling/Wall Opening: 112" Recess: . 2-5116"(59 mm)Minimum (13m 4-112" (115 mm)Maximum Threaded `�" Adjustable 2-118" �"t. Outer Cup (54 mm) _________i_ +'' 13!16" A ,r .»,: (21 mm) -- � ��� Maximum 6-116„ 1 Extension: 3132" {130 mm) -� F 11132" (2 mm)�— (9mm) Figure 4: Installation of a Thread-on Style Model E-3 Recessed Escutcheon with 27/32"(21 mm)Total Adjustment. Form No.F_122698 17.02.02 Rev.17.1 e t r Page 9 of 10 NiluNG® TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Depth: Adjustable 23/32"(18 mm) Adapter Ring ___i_ Ali a .... ".1:,,,, ,- ',4' # , Maximum Recess: Ceiling/Wall Opening: 1/4"(6 mm) 2-5/16"(59 mm)Minimum 2-1/2"(64 mm)Maximum 1-1/16" Adjustable 2-1/8" (27 mm) Outer Cup ft(54mmY* 4•`, 1/8" 3-1/16" 1_ (78 mm) Maximum Extension: 1/4"(6 mm) Figure 5: Installation of a Model F-1 Adjustable Escutcheon with 1/2"(12 mm)Total Adjustment. 1/8" 41 (3 mm) Adjustable Outer Cup Adjustable Outer Cup Illilii IIIIE 4 .,,... ---f-- .-; 2-5/6" q" " (66 mm) 7 (102 mm)1.4 Depth )01 1-1/16" (27 mm) Maximum Recess: 1-1/16" —411C-4111" .I (27 mm) T 1/2"(13 mm) Figure 6: Installation of the Model G-1 Recessed Escutcheon with up to 1/2"(12.7 mm)Adjustment. Form No.F_122698 17.02.02 Rev. 17.1 R , 1 Page 10 of 10 NiiiKING® TECHNICAL DATA SPRINKLER ESCUTCHEONS The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. A. +.Si X40_ ii,:l'11r J‘ Keep the leading edge of the HSW deflector parallel Quick Response77 '''''''' E with the ceiling HSW Sprinkler installed with the Model G-1 Shown with sprinkler installed at the peak Recessed Escutcheon of a sloped ceiling with spray directed down the slope. (Refer to the appropriate sprinkler technical data page for listings and approvals.) Figure 7: Model G-1 Recessed Escutcheon Installed with a Residential HSW Sprinkler below a sloped ceiling. Form No.F_122698 17.02.02 Rev.17.1 Replaces page 135a-i dated July 22,2013. (Removed 13220,06420A and 06912A and added 20123,20369 and 20371) * Page 1 of 5 MIMING 0 TECHNICAL DATA CONCEALED SPRINKLER COVER PLATE ASSEMBLIES The Telephone: 269-945-9501 Technical iSeryces: 877-384-5464 ng Corporation,210 N [ Faxal : 269-818-Hastings MI 49058 1. DESCRIPTION 1680 Email: techsvcs@vikingcorp.com Viking Cover Plates are low-profile covers used with Viking Concealed Sprinklers.The covers are installed flush with the wall to provide a smooth appearance,and are available in several standard decorative finishes to meet design requirements. Cover Plates may also be custom ordered with any color byanyceiling or 2. LISTINGS AND APPROVALS paint manufacturer. Viking Refer to the Approval Charts on the applicable Viking Sprinkler Technical Data Pages. 3. TECHNICAL DATA Specifications: Refer to the appropriate sprinkler technical page for sprinkler specifications. Material Standards: -C11000, Brass UNS-C26000 or UNSViking Technical Data may be found on C26800 The Viking Corporation's Web site at Cover Plate Assembly: Copper UNS - Spring: Nickel Alloy http://www.vikinggroupinc.com.Eutkelic Eutectic for cover 15765) include air. The Web site may a more recent Ordering Information: (Also refer to the current Vikin edition of this Technical Data Page. Refer to Tables la, lb, and 2. 9 price list.) Specify finish and temperature rating of the cover plate assembly by addin the a temperature rating to the base part number: g ppropriate suffixes for the finish and the cover For example, cover 09804 with a Polished Chrome finish and a 165 °F(74 °C)temperature rating =09804FC. Available Finishes And Temperature Ratings: Refer to Tables la, lb, and 2. 4. INSTALLATION A.After installation of the Concealed Sprinkler,testing of the system, repairing of all leaks, and installation and paintingof or ceiling, the concealed sprinkler cover plate assembly may be attached. 1. Remove the plastic protective cap from the sprinkler. the wall 2. Remove the cover plate assembly from the protective box, taking care not to damage the assembly. 3. Gently place the base of the cover plate assembly over the sprinkler protruding through the opening**in the ceiling or wall. **Size depends on the sprinkler model used. Refer to appropriate sprinkler data page. 4.Carefully push the cover plate assembly onto the sprinkler,using even pressure with the palm of the hand,until the unfinished brass flange of the cover plate base(or the cover adapter, if used)touches the surface of the ceiling or wall.The maximum adjustment available is'/"(12.7 mm)[1/4"(6.4 mm)for sprinklers VK480,VK481 and VK680].DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler nipple. B. DISASSEMBLY:Cover plates can be removed either by gently unthreading them or pulling them off the sprinkler body(depends on the sprinkler model used). C. RE-ASSEMBLY:The push-on feature of these cover plate assemblies allows easy installation of the cover plates. epends 1. Gently place the base of the cover plate assembly over the sprinkler. 2. Push the cover plate assembly onto the sprinkler, using even pressure with the palm of the hand, until the unfinished brass flange of the cover plate base touches the ceiling or wall. 5. OPERATION During fire conditions,when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the sprinkler causes the operating element to fuse or shatter(depending on the type of sprinkler the sealing assembly. Water flowing through the sprinkler orifice strikes the deflector or flow shaper, forming a uniform spray pat- tern to extinguish or control the fire. ), releasing 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking concealed sprinklers and cover assemblies are available through a network of domestic and international distributor The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE s. See For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_040600 16.02.11 Rev 16.1 Replaces pages 136a-d,dated May 21,2013. (Added VK4880,and 165°F temp-rated versions of residential covers) M 4 Page 2of5 NIIIIKING® CONCEALED SPRINKLER TECHNICAL DATA COVER PLATE ASSEMBLIES The Viking Corporation,210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269445-9501 Technical Services: 877384-5464 Fax: 269-81880 Email: techsvcs@vikingcorp.com TABLE 1a:COMMERCIAL COVER ASSEMBLIES 2-3/4" F, F-/B, B,B-/A, B-/B, VK404(Obs) 20a-e 09804 Flat Pendent 165°F (74°C)=C (70 mm) E-/B, M-/W, M-/I, M-/B VK454 (Obs) VK404 (Obs) 20a-e 2-3/4" VK454 (Obs) IIN 135°F (57 °C) =A 70 mm) Flat Pendent MEIMI F, F-/B, B, B-/A, B-/B, VK408 (Obs) 63a-e 135 °F (57 °C) A 2-3/4" E-/B,M-/W, M-/I, M-/B 11451 Flat Sidewall and 165°F (74 C)_ C (70 mm) 3-5/16" F, F-/B, B, B-/A,B-/B, VK404 and VK454 Flat Commercial (57 ° = =C (84 mm) E-/B, M-/W, M-/l,M-/B (Obs) 11697 (large diameter) andd 1 1655°FF (744°C) VK102 and VK202 F_101912 VK190 F_092003 VK192 F_081311 VK194 F_092103 VK196 F_092203 Domed Pendent/ 135°F (57 °C)=A 3-1/8" F, B, M-/W, M-/l,M-/B VK302 F_033614 12381 Dry Pendent and 165°F (74°C)=C (80 mm) F_102112 MOM F_102212 VK614 and VK616 F_061603 O VK618 F_061503 VK630 F-84h-m051028 135 °F (57°C)=A 3-1/8" VK VK (Obs) 28 13501 Domed Sidewall and 165°F(74°C)= C (80 mm) F VK461 _091506 VK462 and VK463 F_103005 VK462 and VK464 F_062908 135 °F (57 °C)=A 2-3/4" F, F-/B,B,B-/A,B-/B, MRI 13504 Flat Pendent and 165°F (74°C)= C (70 mm) E-/B, M-/W, M-/l, M-/B VK464 F_021606 VK465 F_032107 VK632 and VK634 F_080107 VK461 F_091506 VK462 and VK463 F_103005 VK462 and VK464 F_062908 Flat Commercial 135°F (57 °C)=A 3-5/16" F, F-/B,B,B-/A,B-/B, MRI 13642 (large diameter) and 165°F (74°C)=C (84 mm) E-/B, M-/W, M-/l, M-/B VK464 F_021606 VK465 F_032107 VK632 and VK634 F_080107 Notes 'Base part number is shown.For complete part number,add finish suffix and temperature suffix. 2 Custom colors are also available. 3 Finish Suffixes:Polished Chrome=F,Brushed Chrome rated F-/BlaB, BrighB Brass=B,Antique Brass=B-/A, Brushed Brass= B-/B,Brushed Copper= E-/B,Painted White=M-IW,Painted Ivory=M , (Continued on page 3.) Form No.F_040600 16.02.11 Rev 16.1 . 9 Page 3 of 5 1 NIKING® TECHNICAL DATA CONCEALED SPRINKLER COVER PLATE ASSEMBLIES The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE lb(continued): COMMERCIAL COVER ASSEMBLIES 11111.111111.—" Cleanroom ( Flat Commercial 135 °F(57°C)=A 3-5/16" F-/CR,/W/CR, ' 13642-/CR (large diameter) and 165 °F(74 °C)= C (84 mm) /I/CR,/B/CR 6462(JQR F_022409 Cleanroom 135 °F (57°C) 13642-/CR Flat Commercial =A 3-5/16" F-/CR,/W/CR,/I/CR, (large diameter) and 165 °F(74 °C)= C (84 mm) /B/CR VK464(SR) F_022409 Cleanroom 135 °F(57°C) 15765-/CR Flat Commercial =A 3-5/16" F-/CR,/W/CR,/I/CR, (large diameter) and 165 °F(74 °C)= C (84 mm) /B/CR VK469(QR) F_120508 VK461 F_091506 Flat Commercial F, F-/BBB-/A B-/B VK462 and VK463 F 100305 15394 (square cover 135 °F(57 °C)=A 3-5/16" – plate) and 165 °F(74 °C)= C (84 mm) M-/W, Bl, M-/B VK464 F_021606 VK465 F_032107 VK632 and VK634 F_080107 15765 Flat Pendent 135 °F(57 °C)=A 3-5/16" VK469 F_120508 and 165 °F (74 °C)= C (84 mm) F, M-/VV, M-/I, M-/B VK636 F_121009 Flat HSW 135 °F(57°C)=A 3-5/16" F, F-/B, B, B-/A,B-/BVK538 F_050511 16207 VK481 F lar.e diameter and 165 °F 74 °C = C 84 mm E-/B, M-/W, M-/I, M-/B – 020312 16207 Flat HSW 135 °F(57 ° 3-5/16" lar.e diameter C)=A 84 mm F, M-/W, M-/I, M-/B VK680 F_050611 Notes 1 Base part number is shown.For complete part number,add finish suffix and temperature suffix. 2 Custom colors are also available. 3 Finish Suffixes:Polished Chrome=F,Brushed Chrome=F-/B,Bright Brass=B,Antique Brass=B-/A,Brushed Brass=B-/B,Brushed Copper=E-/B, Painted White=M-/W, Painted Ivory=M-/i, Painted Black=M-/B Form No.F_040600 16.02.11 Rev 16.1 Page 4 of 5 NIKING® CONCEALED SPRINKLER TECHNICAL DATA COVER PLATE ASSEMBLIES The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 2: RESIDENTIAL COVER ASSEMBLIES VK466 F 091606 Domed 3-1/8" F, F-/B,B, B-/A,B-/B, VK458 F_092305 12207 135°F(57 °C)=A (80 mm) E-/B, M-/W, M-/I, M-/B VK468 F_020206 Residential VK4574 F_072607 VK474 F_012109 VK45704 F 100710 an 135 °F °C)=A 2-3/4" F, F-/B, B, B-/A,B-/B, VK4740 F_012811 13504 Flat Residential and (70 mm) E-/B, M-/W, M-/I, M-/B VK488 F_073012 165°F(74°C)=C VK4880 F_061214 2-3/4" F, F-/B,B,B-/A,B-/B, VK425(Obs) 147a-c(Obs) 10786 Flat Residential 135°F (57 °C)=A (70 mm) E-/B, M-/W, M-/I, M-/B VK4574 F_072607 VK474 F_012109 VK45704 F_100710 135°F (57 °C)=A 3-5/16" F, F-/B, B, B-/A, B-/B, VK4740 F_012811 13642 Flat Residential and F_073012 (large diameter) 165°F(74°C)=C (84 mm) E-/B, M-/W, M-/I, M-/B VK488 VK4880 F_061214 VK4574 F_072607 VK474 F_012109 VK45704 F_100710 Flat Residential 135°F (57 °C)=A 3-5/16" F, F-/B, B, B-/A,B/B, VK4740 F_100711 15394 (square cover and (84 mm) E-/B, M-/W, M-/I, M-/B VK488 F_073012 plate) 165°F(74°C)=C VK4880 F_061214 Flat HSW 3-5/16" M_�y VK480 F_121609 16207 Residential 135°F (57 °C)=A (84 mm) (large diameter) Notes 'Base part number is shown.For complete part number,add finish suffix and temperature suffix. 2 Custom colors are also available. 3 Finish Suffixes:Polished Chrome=F,Brushed Chrome=F-/B,Bright Brass=B,Antique Brass=B-/A,Brushed Brass=B-/B,Brushed Copper=E-/B, Painted White=M-/W,Painted Ivory=M-/I,Painted Black=M-/B 4 Not compatible with the 165°F(74°C)temperature rated covers. Form No.F_040600 16.02.11 Rev 16.1 f f Page 5 of 5 I NIKING® TECHNICAL DATA CONCEALED SPRINKLER COVER PLATE ASSEMBLIES The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1...111IIIam IIIII00 -� �- d U j flu I 09804 and 11225 11697 11451 15394 16207 um— 11 otf-- Q -_____—. \ii �� ' ' 1 -- �� it ��I 44 � ..i.L .s..„_.).. ,wm, , ..L, tra: :m I 12207 and 12381 10786 13504 13642 and 15765 13501 Figure 1 TABLE 3 4f'- I ri VK102 12381 VK454 09804, 11225, 11697 . , VK481 16207 VK190 12381 VK457 and VK4570 13504, 13642, 15394 VK488 and VK4880 13504, 13642, 15394 VK192 12381 VK458 12207 VK538 15765 VK194 12381 VK461 13504, 13642, 15394 VK614 12381 VK196 12381 VK462 13504, 13642, 15394 VK616 VK202 12381 VK463 13504, 13642, 15394 12381 VK302 12381 VK618 12381 VK464 13504, 13642, 15394 VK630 VK352 12381 VK465 13504, 13642, 15394 13501 VK353 12381 VKVK631 13501 466 12207 VK632 13504, 13642, 15394 VK404 09804, 11225, 11697 VK468 12207 VK634 13504, 13642, 15394 VK405 (Obs) 09804, 11225 VK469 15765 VK636 15765 VK408 (Obs) 11451 VK474 and VK4740 13504, 13642, 15394 VK425(Obs) 10786 VK680 16207 VK480 16207 Form No.F_040600 16.02.11 Rev 16.1 Replaces pages 136a-d,dated May 21,2013. (Added VK4880,and 165 °F temp-rated versions of residential covers) Page 1 of 5 NIKING TECHNICAL DATA SPRINKLER WRENCHES AND CABINETS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION A.Sprinkler Cabinets Viking sprinkler cabinets are metal enclosures constructed to store an emergency supply of spare sprinklers and a sprinkler instal- lation wrench. NFPA 13 requires a representative number of each type and temperature rating of sprinkler head to be kept in a cabinet on the premises. NFPA 13 also requires a special sprinkler wrench to be provided in the cabinet.This allows for immediate removal and replacement of sprinklers that have operated or that have become damaged. Stock of spare sprinklers should include sprinklers of all the types and temperature ratings as are installed in the sprinkler system, in the following quantities: Number of Minimum Number Sprinklers in of Spare Sprinklers the System Required Under 300 6 300-1,000 12 Over 1,000 24 B.Sprinkler Wrenches Viking sprinkler wrenches are special installation tools specifically designed for use with the various Viking sprinklers and spray nozzles. The appropriate wrenches must be used with the indicated sprinklers and nozzles to provide the proper leverage when tightening sprinklers or nozzles and to minimize slippage during installation. Using wrenches other than the ones designated for installation may damage the sprinkler. Refer to Tables 2a and 2b and the ap- propriate sprinkler or spray nozzle data page for the correct installation wrenches that must be used. Wrenches 10896W/B, 07297W/B, 05118CW/B, 13635W/B, and 16888M/B provide the amount of leverage needed to tighten sprinklers and spray nozzles into pipe fittings while preventing sprinkler damage. No additional tools are necessary with these wrenches. The following wrenches require a separate ''/2 ratchet (not available from Viking) to provide the correct amount of leverage: 08336W/B, 10366W/B,07565W/B, 11663W/B, 13032W/B, 13577W/B, 13619, 15466, 13623W/B, 15467W/B, 15209W/R, 13655W/B, 14031, 14047W/B, 16208W/R, and 16267. The internal diameters of sprinkler wrenches 08336W/B, 10366W/B, 15209W/R, 16036W/B, 16208W/R, and 16267 are designed for use with the sprinkler contained in the protective shell. (A protective shell should be retained in the spare sprinkler cabinet.) Wrench part number 10551W/B is required for threading institutional escutcheon plates onto institutional sprinklers. Wrench part number 10729 is a 2-1/2"(63.5 mm)C-C face spanner wrench used for removing institutional escutcheon plates from institutional sprinklers(refer to the DISASSEMBLY section of institutional sprinkler technical data pages). Wrench part number 15915 is optional for removing protective sprinkler caps and for installing E-1 and F-1 Escutcheons on frame style pendent sprinklers from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Refer to Technical Bulletin Form No. 051808. 2. LISTINGS AND APPROVALS Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals. 3. TECHNICAL DATA Specifications: Sprinkler Cabinets: Designed with four 3/16" diameter holes in back. Spacing of mounting holes:3-1/2"(88.9 mm)length,3-1/2"(88.9 mm)height. Viking Technical Data may be found on The sprinkler cabinet should be located adjacent to the main system riser. The Viking Corporation's Web site at Material Standards: Sprinkler Cabinets: Cold Rolled Steel. Finish: Painted high-gloss red enam- hrtp•//"�"N"vikinggroupinc.com. el interior and exterior, chrome plated door knob. The Web site may include a more recent Wrenches: Ductile Iron, Steel,Acetal, or 50%glass filled nylon(for head edition of this Technical Data Page. cabinet wrenches) Form No. F_122598 Rev. 15.1 ♦ v Page 2 of 5 NIKING® SPRINKLER WRENCHES TECHNICAL DATA AND CABINETS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) A. Sprinkler Cabinets page for use with the specific model/number of sprinklers to be contained 1.Determine appropriate cabinet from Table 1 on this in the cabinet. 2.Specify cabinet part number and quantity needed. B.Sprinkler Wrenches 1.Determine the appropriate wrench for use with the given sprinkler or spray nozzle model from Tables 2a and 2b. 2.Specify the wrench part number and quantity needed. NOTE: Sprinklers and sprinkler wrenches are not supplied with the cabinets;they must be ordered separately. 4. INSTALLATION Refer to the appropriate sprinkler or spray nozzle technical data page. 5. OPERATION Refer to the sprinkler or spray nozzle techical data page for the particular model used. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking sprinkler wrenches and cabinets are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Size Cabinet Cabinet For Sprinkler Models: Capacity Part No. Length Height Depth �17 ' 10-3/16" 4-11/16" 2-9/16" 24A 65 mm) Viking frame style sprinklers 6 sprinklers d IN since (259 mm) (103 mm) Viking frame style sprinklers, 8-9/16" 2-9/16 12 sprinklers 01725A 10-3/16" 6-5 mm) ESFR K14 sprinklers, (6 K25.2 EC mm) K16.8 pendent sprinklers, sprinklers) Available since 1971. (259 mm) (217 and K25.2 EC sprinklers Viking concealed and flush style 13-13/16" 5 11116" 3" sprinklers, ESFR K25.2 and K22.4 5-6 sprinklers 01731A 144 mm (76 mm) pendent sprinklers, and K19.6 Available since 1971. (351 mm) ( ) CMSA sprinklers 9-1/8" 4-1/8" High Challenge®Sprinklers, 03985A 12-5/8" 105 mm) upright ESFR sprinklers, 6 sprinklers Available since 1977 (321 mm) (232 mm) and Intermediate Level Sprinklers Table 1: Sprinkler Cabinets Form No. F_122598 Rev. 15.1 w L Page 3 of 5 INIIKING a TECHNICAL DATA SPRINKLER WRENCHES AND CABINETS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com IMPORTANT NOTES The sprinkler cabinet should be easily accessible. The sprinkler cabinet must not be exposed to corrosive atmospheres or temperatures above 100 °F(38 °C). The stock of spare sprinklers should include an adequate number of sprinklers of each type and temperature rating. The stock of sprinklers must be in good condition. A sprinkler wrench of the appropriate type must be included in the cabinet. Orient sprinklers and sprinkler wrench as indicated in Figure 1 below. CAUTION: When replacing automatic sprinklers in an existing system, be sure to replace with sprinklers of the correct type, thread size, orifice size, temperature rating, and finish. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the appropriate sprinkler data page. Viking sprinklers and spray nozzles are designed to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. \ 7 , 9 � i � i11.� G.� t A c3A 4.f; I��� ��� f�� ��� St1.1 1t, A'.F%J b c StE 5f,il.f:: SI iI ��� i�� ,(,,IC I^:.0 r;lL.°. -El.�GF*rtr .# . .-1, i , 1 tq ,- �' ' J_ ' c^a a :.:= ' ¢ r .'e ft {+t fc . _ii R Figure 1: Correct orientation of sprinklers and wrench inside cabinet. Figure 2: Sprinkler Cabinet 01724A Figure 3: Sprinkler Cabinet 01725A (12-head cabinet shown) (Sprinklers and wrench not included) (Sprinklers and wrench not included) Form No. F_122598 Rev. 15.1 1 M Page 4:6.o):0 5 ® SPRINKLER WRENCHE TECHNICAL DATA AlND CABINETS The Viking Corporation,210 N Industrial Park Drive, Hastings M 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorm For Sprinkler Models: Use Wrench: 10896W/B Available since 2000 �� 10896 Frame-style sprinklers and spray nozzles or 05000CW/B" �'� Wax coated sprinklers and domed 13577W/B Available since Part No.10896W/B concealed pendent sprinklers 2006 replaces 07398W" L Recessed horizontal sidewall sprinklers with protective shields,domed concealed 13655W/B l horizontal sidewall sprinklers, and recessed Available since 2006 part No.13577W/6 &13032WI6 pendent sprinklers Coated and recessed ECOH K14 sprinkler 13032W/B Available since 2004 VIKING men Q�) Standard adjustable and plain barrel dry 07297W/B Available since 1991 sprinklers, K16.8 and ECOH K14 sprinklers Part No.07297W/B Recessed and domed concealed dry sprinklers 07565W/B Available since 1991 High Challenge®sprinklers, upright ESFR 05118CW/B sprinklers, and ELO sprinklers** Available since 1981 Part Nos.07565W/B part No.13655W/B Coated, recessed, and domed 11663W/B >3<11663W/B concealed ELO sprinklers Available since 2001 13635W/B double ended (use Side A) Pendent K14 and K16.8 ESFR sprinklers Available since 2006,or 10285W/B" Pendent K25.2, K22.4 ESFR sprinklers 13635W/B double ended (use Side B) Part No.05118CW/B and K19.6 CMSA Sprinkler VK592 Available since 2006,or 12143W/B" 16888M/B ,A. VIKINC 13635 t B Upright EC K25.2 sprinklers Available since 2011 Part No.13635W/B QR and EC Concealed Sprinklers VK461, 14031t VK462,VK463,VK464,VK465,VK632, and Available since 2006 VK634(also optional for cap removal) Call111111111::3111111111111111.41C QR and EC Concealed Sprinklers 14047W/B (heavy duty) VK461,VK462,VK463,VK464,VK465, Available since 2006 Part No.16888M/B VK632, and VK634 Residential Concealed Sprinklers 13619t (red) VK456,VK457,VK474, and VK488 Available since 2006 (also optional for removal of protective caps) r 'Wrench no longer available.May still be used until wrench replacement is necessary. Part No.14031 Part No.14047W/B ""ELO sprinklers manufactured before Dec.2001 use wrench part number 07297W/B(07565W/B Figure 4a: Sprinkler Wrenches for coated and recessed). tldeal for sprinkler cabinets. Table 2a: Sprinkler Wrenches Form No. F_122598 Rev. 15.1 r l Page 5 of 5 NIKING® TECHNICAL DATA SPRINKLER WRENCHES AND CABINETS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com For Sprinkler Models: Use Wrench: Residential Concealed Sprinklers 13623W/B (heavy duty) VK456, VK457, VK474, and VK488 Available since 2006NI Residential Concealed HSW Sprinkler VK480 16267t or 16208W/R(heavy duty) ___ Available since 2010 Part Nos.13619 Part Nos.13623W/B Mirage®QR ELO Concealed Sprinklers &15466 15467W/B VK636 and VK469 (also optional for 15466t removal of protective caps) Available since 2009 1 Tro Mirage®QR ELO Concealed Sprinklers 15467W/B (heavy duty) ,1 VK636 and VK469 Available since 2009 08336W/B(heavy duty) Part No.16267 Part No.16208W/R Mirage®Concealed and flush style sprinklers Available since 1993 _ Mirage®Concealed and flush style sprinklers 10366W/Bt Available since 1998 ] I p Residential Flush Pendent Sprinklers — -- I. p 15209W/R(heavy duty) VK476 and VK478 Available since 2009 Part No.08336W/B Part No.10366W/B Recessed Flush Dry Sprinklers VK482 18315(heavy duty) Available since 2014 Mirage®and Freedom®Concealed Sprinklers VK461,VK462, VK463, VK464, VK465, 14412t, or 14867 for the large ** VK469,VK474, VK632, VK634,VK636, and diameter cover,Available since 2007 VK488 (optional concealed cover installer tool) Part No.15209W/R Part No.14412 Shipping Cap Remover/ _ �� Escutcheon Installer(optional***) 159151 Available since 2010 J Institutional style flush sprinklers 10551W/B (for installation of the escutcheon plate) Available since 199911110 Part No.14867 Part No.15915 Institutional style flush sprinklers(spanner wrench for escutcheon plate removal) 10729 Available since 1999 _ ***Allows removal of sprinkler caps and installation of E-1 and F-1 escutcheons on frame style r >MIME. pendent sprinklers from the floor. J ( tldeal for sprinkler cabinets. Part No.10551W/B Part No. 10729 Table 2b: Sprinkler Wrenches i i u—; Part No.18315 Figure 4b: Sprinkler Wrenches Form No. F_122598 Rev. 15.1 FireLock® Butterfly Valve �CtauliC" Series 705 with Weatherproof Actuator 10.81 1 , CI ' 1.0 PRODUCT DESCRIPTION • Available Sizes: 2— 12"/50—300 mm • cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa/20 bar. • Designed for fire protection services only. • Features a weatherproof actuator housing Approved for indoor and outdoor use. • Actuation options: Hand wheel (2— 12950—300 mm) • Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS)groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c®,a a LPCB USTED G410001 104j/04 NOTES • Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • System No. Location 1 ! Spec Section Paragraph Submitted By Date 1 — 1 i � Approved Date � —' — — victaulic.com 10.81 5662 Rev H Updated 03/2017 ©2017 Victaulic Company.All rights reserved. 1 jctauli[:' victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB pto 3OOpsi/2068kPa N', , ,,nn/a up to 300psiI2O68kPau"p"t m '' 11-,A- 21h up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 65 ,, 4 to 3, sr/2068kPa a $p O68'kP+3 " �BOpt •' kPa "r a 3 TT P Opp w f = , •n TO' . .-L o- ''''..-5' _� _ ,; _ � , s,�. sem.._, s 3 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 80 o up to 300psr/2068kj'a tup o 0psi/,2068kP r s to 300psi/2063kPa ;+p to300Psi/ 068 .100 , ,,,,,,,,1,/.1,- ... ,._. 5 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 125 .�-, ^� ,�r.�, ..ter 4 ,rel "� , 339.7mm UP to 30 psr/2068kPa ,,r 5pto 00psj%2O 6 kPa i pto 300psi/2068 Pa up tp 'e,psi/ 068kkPa 6 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa� up to 300psi/2068kPa 150 3 r stS s . , , 1,p,.m,, P't4$09psi/2 m,,,,, , F, P= ` r1.1: c. _ -t-;-4 " ,1 W--.,,.:f-„t,.„ 4'7,;,;/..;"1. -4.4454 I up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 200 '10 up to 300psi/2 i68kPp up to SOOpsi/2068kPa a " } -up to 3 a 206#kPa .,,3,, ,.r�. ':14-,. „„.w,>s,Ls.,'". b .,_...,,,,,`,.n.,,,,,' fi w� , ` v1- .' '`+ta,,it, 12 � up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 300 3.0 SPECIFICATIONS-MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2—6"150— 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8— 12"/200—300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12,with electroless nickel coating conforming to ASTM B-733 Seat:Grade "E" EPDM Stems:416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 2—8750—200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing 10—12'7250—300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing . 10.81 5662 Rev H Updated 03/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic victaulic.com • 4.0 DIMENSIONS • Series 705 11 -@J- s• P)H 1•111=1111. *F-elPf Al. 5 C 111.1 !1/4 sss,,,L ,, _} 1 F 1 G E E-- A 1+-D Size Dimensions Actual Outside E to E DIA 1 Nominal Diameter A B C I D E F G H j inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2375 4.25 2.28 6.41 _ 4.00 4.22 450 2.12 60.3 60.3 108.0 57.9 I 162.8 - 101.6 107.2 _114.3` 53.8 21/2 2.875 3.77 2.28 7.54 - _ 4.00 4.22 4.50 1.77 73 73.0 95.8 _ 57.9 191.5 101.6 107.2 114.3 45.0 3.000 3.77 2.28 7.54 76.1 mm - - 4.00 4.22 4.50 ., 1.77 76.1` 95.8 57.9 1915 101.6 107 2 114.3 45.0 3 3.500 3.77 2.53 7.79 _ 4.50 4.22 450 1.77 88.9 88.9 95.8 64.3 197.9 - 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 _ 5.50 4.22- 4.50 ,2.20 108.0 117.6 ` 732 223.E 139.7" 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 _ 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5,88 133 mm 3.35 10.88 _ 4•56 6.19 °6.30 . .2.58 133.0 149.4 85.1 276.4 - 166.6 157.2 160.0 65.5 139.7 mm 5.500 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 __ 139.7 I 149.4 _ 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 5.88 3.35 10.88 _ 6.56 6.19 6.30 2.58 1 141.3 141.3 149.4 85.1 276.4 - 166.6 157.2 160.0 653 159 mm 6.250 5.88 3.84 11.38 0.41 7.52 6.19 6.30 258 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1mm 6500 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 238 } 165.1 149.4 97.5 289.1 10.4 191.0 r 157.2 160.0 653 6 6.625 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 1.90 1683 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 533 5.07 1333 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 203 37.3 254.0 157.2 205.7` 592 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 273 273.0 I 162.6 161.8 1 397.3 35.8 46.0 311.2 205.7 228.6 _ 12 i 736 323.9 � 323 90 165.1 86 9 I 422.7 I 58.4 230 1 71.18 362.0 I 205.7 228.6 14.25 8.10 - NOTE • Optional W/15 mm tap available.Contact Victaulic for details. • • 10.81 5662 Rev H Updated 03/2017 C 2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓atQUlle I 4 victaulic.com • 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/m inches inches of pipe 2 2.375 6 50 °.60.3 1.8 2+/2 2.875 6 65 73.0 1.8 76.1 mm 6- 3 3.500 7 80 88.9 2.1 4 4.500 a.,43 100 e. 11'43 2.4 ; 108 mm 108 mm 2. 2.4 125 X141.3 — 37 __ 133 mm 133 mm 12 3.7 139.7mm 6 6.625 14 150 168.3 4.2 159 mm 159 min 165.1 mm 6.500 14 165.1 4.2 8 .625 X16 -200 10 10.750 18 250 273.0 5.5 12 12'7.50 19 1 • • 10.81 5662 Rev H Updated 03/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic° victaulic.com 5.1 PERFORMANCE Series 705 Cv values for flow of water at+60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for CY values Formulas for K„values AP = 02 Where: pp= Q2 Where: Cy'zz Q=Flow(GPM) K zz Q=Flow(m3/hr) 4P=Pressure Drop(psi) vpp=Pressure Drop(Bar) Q = Cv x 4P C =Flow Coefficient Q = Kv x 1AT Kv=Flow Coefficient Valve Size Full Open Valve Size Full Open Actual Actual Nominal Outside Nominal Outside Size Diameter Flow Coefficient Size Diameter Flow Coefficient inches inches C„ inches inches lc, mm mm mm mm 2 2375 1 2 2375 147 1 50 603 170 50 603 21/2 2.875 2'k 2.875 65 73.0 260 65 73.0 225 76.1 mm 7000 I 260 I 761 mm � 0 225 3 3.500 3 3.500 80 88.9 440 80 88.9 380 4 4.500 820 4 4.500 710 100 1143 100 114.3 108mm 108mm 820 108mm 108mm 710 - 5 5563 5 5.563JJl 125 1413 --._�- 1200 125 141.3 10 - 40 133mm 133mm 1200 133mm 133mm 1040 5.500 5.500 139.7mm 139.7 1200 139.7mm 139.7 1040 6 6.625 6 6.625 150 168.3 1800 150 168.3 � 1560 --— ----- ----- - - 159 mm 159 mm 1800 159 mm 159 mm - -_- 1560 .500 .500 165.1 mm 665 1800 165.1 mm 665 1560 8 8.6258 8.625 200 219.1 3400 200 219.1 2940 10 10.750 10 10.750 250 273.0 5800 _ 250 273.0 5020 12 12.750 12 12.750 300 323.9 9000 300 I 323.9 7790 10.81 5662 Rev H Updated 03/2017 ©2017 Victaulic Company.MI rights reserved. victaulic.com 5 ✓ataulila' victaulic.com • 6.0 NOTIFICATIONS \_ 0 IGO 0 1(0(1 • Read and understand all instructions before attempting to install,remove,adjust,or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove,adjust,or maintain any Victaulic piping products. • Wear safety glasses, hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring 1. The supervisory switch contains two single pole, TED double throw, pre-wired switches. IUUIUO NB NCiION U 2. Switches are rated: CTROUT 10 amps @ 125 or 250 VAC/60 Hz �,- �J•- @ ,��NST 0.50 amps 125 VDC I®I CONDUIT CONNECTORS �` 0.25 amps @ 250 VDC l WIRE NUTS 3. Switches supervise the valve in the "OPEN" position. 5. One switch has two#18 insulated wires per terminal i. I. FIRE ALARM \ TO END-OF-LINE RESISTOR, which permit complete supervision of leads(refer CONTROL ONTRSUPELPANEL \ OR NEXT INDICATOR to diagrams and notes below).The second switch CIRCUIT i ' has one#18 insulated wire per terminal. This double SWITCH N NO COM circuit provides flexibility to operate two electrical CONTACT RATING, t • U 10A AT 125 AND ■ 51 ��/ devices at separate locations, such as an indicating 250VAC, -i ❑ C 0.5A AT 125VDC, light and an audible alarm, in the area that the valve 025 AT 250 VDC ■ 52 • BELL is installed. . ' -I ri r- OR VOLTAGE SOURCE r HORN 6. A#14 insulated ground lead (green) is provided. Switch 1:2 leads per terminal Switch#1 =S1 Switch 2:l lead per terminal For connection to the supervisory circuit of a UL Listed alarm control panel NOTES • The above diagram shows a connection between the common terminal Switch#2=S2 (yellow—SI and yellow-with-orange stripe—S2)and the normally closed terminal(blue—S1 and blue-with-orange stripe—S2).In this example, Auxiliary switch that may be connected to auxiliary the indicator light and alarm wit stay on until the valve is fully open.When devices, per the authority having jurisdiction the valve is fully open,the indicator light and alarm wit go out.Cap off any unused wires(e.g.brown with orange stripe). Normally Closed: (2) Blue • Only SI(two leads per terminal)may be connected to the fire alarm Si control panel. Common: (2) Yellow • The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70(NEC). Normally Closed: Blue with Orange Stripe s2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe , 10.81 5662 Rev H Updated 03/2017 C 2017 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulic° 4 victaulic.com 7.1 REFERENCE MATERILS 10.01:Regulatory Approval Reference GuidAe 29.01:Terms and Conditions/Warranty 1-100:Field Installation Handbook • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard standards ands projectlas Victaulic and the applicable building,safety,ands and related equipment without notice and without incurring obligations. regulations as well Victaulic performance,maintenance, and warning instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries Trademarks or affiliates covering such use or design,or as a recommendation for the use of such Victaulicmand all other marks are the or of material,product,service,or design in the infringement of any patent or other intellectual Victaulic andCoallot,and/or Victaulic its amarks reetthe trademarks in U.S.and/or registered eredr trademarksk. property right.The terms"Patented"or"Patent Pending"refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. • • 10.81 5662 Rev H Updated 03/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 7 ✓ctaulklc ,96 _ __IPS_CARBON STEELPIP.E .FIRE PROT_CTION PRODUCTS _. _ , , � //�� FireLock® Zone Control F ° Module SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS _ SERIES 747M L ,- Designed for NFPA 13 commercial requirements,the Victaulic Series 747M Zone Control Riser k+ ,` Module features a cast body,and is compact and easy to install in zoned wet sprinkler systems. The integrated module body consists of a shut off valve,test and drain valve combination and different orifice sizes(K factors),a UL Listed and FM Approved Flow Switch,and a Pressure Gauge.The Series 747M FireLock Zone Control Riser Module is available in sizes from 11/4 through 6'/32mm-150mm with grooved ends on the main pipe for installation in the horizontal or vertical up-flow positions with UL Listed,FM Approved Victaulic grooved24000 couplings.1'/4-2"modules have an NPT drain port.21/2-6"modules have a grooved drain port. ,a The Series 747M FireLock Zone Control Riser Module is FM Approved and UL and ULC Listed for working pressures up to 365psi/2517 kPa.An optional pressure relief valve kit is available PATENT STYLE PENDING 747Mfor all sizes.The Pressure Relief Valve is FM Approved and UL and ULC Listed for working pressures up to 175psi/1200kPa. DIMENSIONS AprxE.W e ight xal:e® Mod Module BodySze v z ; $- "% x ; ' : * x n A d " TM � t T T ®I- r_:-.74.1''4711!!! 1'!. 1.660 1 11.45 i 720 5.77 3.50 10.05 • 7.48 2.54 15.2 T �,' 1 32 42.2 33.4 290.8 1829 1465 889 255.3 1900 64.5 6.9 I '! i' C 1 Y 1900 1 11.45 7.32 5.77 3.50 10.05 7.48 2.54 15.5 � € __ F 40 48.3 33.4 290.8 1859 146 5 88 9 255.3 190.0 64.5 7.0 Ez 2 603 1 11.4590. 7.55. ' 57 3.508. 15 7.48 254 19.9 50 60.3 33.4 . 290.8 191.8 � 146.5 88.9 2553 190.0 64.5 9.0 2'/2 r 2.875 1 A 12.00 ' 8.41 6.18 425 9.76 : 11.87 4.25 22.7 E -- G 65 73.0 j 42 305 214 157 !: 108 ' 248 302 108 103 A 3 3.500 1 A 12.00 9.42 6.18 I 425 i 9.76 11.87 4.25 23.2 80 889 42 305 239 ; 157 I 108 1.. 248 302 i 108 10.6 1'/.-2732-50 mm Nominal Sizes 4 4.500 l 212.00 9.90 725 i 5 00 10.15 12.62 4.21 30.3 100 114.3 • 60 305 252 184 127 258 321 107 13.8 `�I° 6 , 6.625 2 12.00 10.85 , 8.31 1 600 10.15 13.62 4.24 36.7 150 1683 60 305 276 211 154 258 346 107.7 16.7 B Lir ei � !� lw Onf ccs �.1111_,,,,,,,704::''.1=1.1115 Nomnal Size -' ,nehe, D ' 1 G --{ C 1.25 K5.6 w L5 K5.6 F I, �" 2 K5.6 r( 25 K5.6 K6.9 K8.0 K11.2 3 K5.6 K6.9 K8.0 K11.2 E . 4 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 6 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 A 21-6765.0-150 mm Nominal Sizes Drain type Drain Size Nominal Size (Valves shown above in the"test"position. inches Shown with optional Pressure Relief Valve Kit NPT 1° installed) 1.25 Hose Clamp 15 NPT 1. 2 NPT 1' 2 5 Grooved 1 AnPressure Relief Valve 3 Grooved 1 1/4 ltiBarbed Fitting 4 Grooved_ 2" Hose Clamp 6 Grooved 2° Close Nipple ~-Drain Tubing ElbowlitBarbed Fitting Optional Pressure Relief Valve Kit Detail _. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com NiCt�UliC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.96_1 REV_I FIRE PROTECTION PRODUCTS-DEVICES 10.96 FireLock® Zone Control Riser Module SERIES 747M MATERIAL SPECIFICATIONS Module Body:Cast from ductile iron conforming to ASTM A-536,grade 65-45-12 with integral Victaulic grooved ends.Finish:orange enamel. Shut-off and Test/Drain Valve:Chrome plated brass ball,S 37700 brass clapper,416SS or 410SS shafts,Delrin orifice,virgin Teflon*,enhanced Teflon and EPDM rubber seals. *Teflon is a registered trademark of Dupont Coupling:Any UL Listed,FM Approved Victaulic IPS-sized coupling may also be used.Note: Couplings not included with product. Waterflow Detector:System Sensor Model WFD/WFDTH vane type waterflow detector with sealed retard,visual switch activation,and mechanical delay adjustment.Cover includes tamper resistant security screws and tool.Note:ULC models WFDA/WFDTHA include cover tamper switch. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. A - WARNING • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. cFailure to follow these instructions may result in serious personal injury, - , property damage,or valve leakage. If you need additional copies of this product literature or the valve � ilb installation instructions,or if you have any questions about the safe installation and use of this device,contact Victaulic Company,P.O. Box 31,Easton,PA 18044-0031 USA,Telephone:001-610-559-3300. For complete contact information,visit www.victaulic.com 10.96 3089 REV I UPDATED 712010 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.CO 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. rCtaUI1C® 10.U6 �_ ..