Plans (62)
r Markup Legend SPRINKLER SYMBOL DEFINITION 1 COLOR/LINETYPE LEGEND / \ R BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). Delete Une / \ / O XXX-XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. w u MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O ;^o =1/2"PIPE SIZE Add Line — — SPRINKLER MODEL(TVP) r ry q j 1 .. CITY OFTIGARD =3/4"PIPE SIZE HEAD SYMBOL(NP) J �-� ^ O ilii,d =1"PIPE SIZE - u Add Tee I Approved rte% — — =1-1/4"PIPE SIZE w a o Vv �z H Conditionally Approved [ > ,._ Add Elbow = .YPw3 See Letter to: Follow 0 Add Coupling I I z a Att<Iciled c°;�w3 Add Head -`� ; -' - Permit Number: MST a 017 - 00216 s � • Address: /304/7 Ski) /69A% AUG, 4= I Delete Head ,7 F I'^'n nna ¢�� By: /4G 67 `,),:;,..-:./2- 1'7-26/7 C�� H Dl h��.�- �z,- .E z5 Move Head u ,4-9za°z °'0x0. E Note:All revisions must be reviewed by Uponor + - - .4 m o"s,7F o Table FOO2-1 z�°ooF4,?', Multipurpose Fire Safety Systems z i° m 2 2'' m z~o The Uponor Residential Fire Safety System is a residential fire protections °°• z n97.°3 =�' system the installed lcontractors rfdomestic W ° aF3z 3 z V water system. Only licensed taiined by Uponor cain all this Usystem. a `L¢°pUF°aas�Wo W What to do it Changes are Required s=waw 3 m Z d. ' V If any features or obstructions require the addition or deletion of sprinkler 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL w <i a o e h heads,or significant relocation of sprinkler heads,contact the Uponor Design 13.0-,2'a'.,2 x,,-, ,,.1,2,-E.,,;,/7.5°z° m u0.00 9 P P 9 CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST P changesrequireredesignFLOOR TO THIRD FLOOR FLOOR TO SECOND FLOOR '=4E2 .,'21. z=u d' y rT. Department to determine If observed a ° F■� (888.594.7726). i 1 r = g~"' u a p o FLOOR,ABOVE- I 6 06 -' zsy�°°d � �zo (T, MOST HYDRAULICALLY REMOTE HEADS (I \ 2-9 5-0 SH 16-6 0 F OVER \\ 3 m❑°m w �> a 3 f■�■) // \ �AFLI�-GLAZING 6-0.-10 SGD - ,I /// l i tt o`�O'•w a� � . '�> -r____ Li � R ®7 f \ \ 4, I °�°�m eo!yo'yo O HEAD# GPM PRESSURE RE DAT STREET i. \k j/ = m`- 7 /� \\ ° ° Y F Q FLOOR BEL9w - Ir--- a=,e° 1 HEAD H.9 17 59.17 TV NICHE / _ .I ' m \ ,"'=r,E.on a AT+3s" "INSULATE FLOOR t '� 2 HEAD H.10&H.8 26.0049 73.95 A.F.F. . : OVER UNHEATED qa ''I� t o m I / \ \ \ �' > z z c ao G g 5 '- . _ SPACE R� �C+rT \1 I E-° 2x6 WALL W/R-21 BATT INSUL WOOD TREAD,MAX. RISER 8" F N y x o z¢ _ w II - au `��F ozs �5E4 CEIL1NeksiD / di I r FACTORY-BUILT / M�� ADD OR REMOVE STEPS AS Liv,.+9_,3,,."ABV•`./ ; f7,4 I I�-_-, DIRECT-iVENT GAS FIREPLACE Q }-, \ \ �3'-0' REQUIRED PER SITE CONDITION) r Q x ���r�. / I q VENT UI6 THRU LOW ROOF/ I / \ s 1st drrioor (} P1�E'RR TRUSS MA-B / 'Th N- TILE FfO) H / �� R OC1UP."_ 10 3ra nl or Rv- C ate Tb SOP iIONALEPLA.. RAWd'�S•Cr Bf r0 R F IL 11 SiS.1 MAIN SHUTOFF S DI! a ,�: B W / VALVE LOCATION\ ABOVE Iz TOTAL m L INL.FLOOR TS AND ROOF RAF/ERS D00 SHALL BE I here by certify that this plan,specification, Q a1 / Al \ AT F/1>\ENCL 5 E I \__ _ SELF SING or report was prepared by me or under my SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 Q ' ,� �\ RC-RES-16/ L .-- -,r4, 20-Mia RX�ED direct supervision and that l am NICET ® - - - 1 K=4.9, 162F°, 7/16"Orifice,Maximum Spacing 18'x18' •r v. 2' 9" 3'--113/./ 3 32. s'A4 j L "I d LIVkle• INSULATE FLOC/OVER Sprinkler head demand: 17gpm @ 12 RADON t RADON\^I UNHEATED sPACEs / 1-1/2"AquaPEX T. 1�FURN. 6A�5 \ Tandem 2-Car certified at Leve IV. RC-RES-18 p I }E ucnoN � SYSTEM 1 !o N Garage REDUCTION I ROXLS-16 T, _i w I-11° 3,4- 10)'2 2' 6 -•v 2'-8° .I C _I SYSTEM _�.� „_ - - -_I - SYS M to Bk :1 a OCCUPANCY Brent D Kotula SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 .� [� ��� Date: Reg.No.113889 �__° a UIQ x.22 - ,e :..:.I WALLY.1(.IISH: 35" ® - - - 14 K=4.9, 162F°,7/16"Orifice, Maximum Spacing 16'x16' t ►5 ��,o � O - \-- .v GWB CEILI FINISH RC-RES-16 Sprinkler head demand: 13 gpm @ 7.04 h� �I 1 � 5'SOW =a i .1 5 t. . 4._1. RD DOWN ss" TYPE" cwH G 2-6 __,7_t _ 1 FOR DUCT RUN FIRE-TAPE A BIFOLD �,'. ■ •�. - M.26 i I - ., I SULATE COC9"W17AF*'9E7f�oSENJU Model RC-RES175 Residential Flat Concealed Pendent 558464 II ;i, o ( . 6 - i BELOW CEILING v Qill ��. ,12,,. / ) I ` / - - 'DER STAIRS K=4.9, 175F°,7/16"Orifice,Maximum Spacing 14'x14' �I II �p�}fpp I- _ a Ar ■ "\- �y i- - LEVEL.INSULATE ® 1 p 9 wl �I�IY C RLr SCI I \ I D LANDING za're I FLOOR ABOVE. Sprinkler head demand: 13gpm 7.04 RC-RES-14-175 P @ A PLANT s N1X1 'p ! a' , 3i- 2 \ km= ,1 SHELF �: I B .-'4-`• m � m " ,.-� '1$ 0 fI ,1 �� I f � I op� �'L�J INSULATE WALL E. \ISI E.-16 ,. ;� c�21 V7111 � � =MI +42 A. F. �.�� (� ___ `- I�E,�f��;f7DETAIL 4/D1 I— O x \ ,n, HHETiE ADJACENT a a / 'R�I�RYE. �i / 'S F _ _I t TO HEATED SPACE q §RES-14-1 5—T 7, A �, M I V o L t '- r• vi I• ��A A'�8-, w- I e m it ' RADON �-I O:::mr�i-I �� ,I�)H,R �A 'I IIS " / •[ 1 T.33 w W4 IE. M �!� Q j f9e -L. t• • .: t S �-- ►7 D5 Q ( T29 I\ MAX. RISER 8" IUB z Li, 3'- ':3 9 ��SQ r }- �--' RC,:,, - . ,� i �F\ tr'.7074-TREAD, (ADC OR REMOVE STEPS AS � \ z o ,AYOQ I RE4UIRED PER SITE CONDITION / / SiW O a. V, ® LRfS 1 AOGESSJ s P H������ I ) V G g CURRENT STATIC EXTERIOR WALL 7- < +"" Wr -- r, , 2 a' W a a w a WATER PRESSURE ELEV=109' I, e�D CAP r' �I MI vi \_ cr1 0 0 0 ~=m u -0 BIPASS "! - C-RES-16 g (^ a nI■ % .` i H. wI1® r�JN T HRR PARTY WALL ' u v, fV O V u<J vl z p H.' G THROUGH FURRING j1_:::Tryi T. No STATIC: SOOpsi / \ \p Try i� E TYPICAL (V M 1-1/4"AquaPEX N 1 1,5 3 x�RC-RES-18 V 0 €� it //7 S TO SYSTEM Tech Rml A —- 0 ,I�1 j '� / '''",,,,,,11-0 R� E C I NG i ' j PP;��©� - -1.15Din./Fam. I W I TO HOT WATER HEATER 1 j '""I oC 3 oh ,s w / 5.1 TYP. SULATE FLOOR OVER ABoa P •,per ` Bedroom 2/ 0 , uRCr�RESs1=@cEs j • m m o / ELEV=104' swamp- r I _ ° ®m ce �/ o Y Y �_ .-m `"1 IIiLI�_FL0On Porch I '® s-o 7-oono W 1/4"FULLPORT - s;sr I j '® 'I W z w % BALL VALVE �' ..d m ut os-axox L re BELOW 7-0 EGRESS XOX r ���0_. FLOORr'ROVE 11 Q W a ROOF , 3'-77/2. 2•-7Y 13'_2.. D5 �/ ~ >m - D �,�/ =m M �r� LL / 1-1/4"WATTS LF25AUB-Z3 moi\ .._ e H V w 6 % 0 OR EQUIVALENT 1..�. n I- �,3 8g g a ELEV=100' ELEV=100' / (15PSI LOSS FLOWING 26P3 THIRD FLOOR %, "z �•'., SECOND FLOOR - FIRST FLOOR g°V a ////////////1 SHEET DESCRIPTION 35'OF 1"METER 100'OF ' F100/ y �1 n — ' F100, i �1 u - t n . F100 • If I ALL LEVELS Ft 1"COPPER-K 1-1/2"AquaPEX 1I' - 1:-0" 1/`P - 11-0 1/`t 11_011 = / 4 WATER SERVICE DETAIL _ S 115 SHEET NUMBER A F100 NTS 1/4"=1'-0" © UPONOR - CONFIDENTIAL F100 Y v Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND I [BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). o OO XXX-XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. w Delete Line 1 BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. a z MAXIMUM SPACING(TYP) —x._ =1/2"PIPE SIZE ' g Add Line — — — — SPRINKLER MODEL(TYP) �'" o HEAD SYMBOL(TVP) �� =3/4"PIPE SIZE C a�W a Add Tee I =1"PIPE SIZE 0 3'u N w = 1-1/4"PIPE SIZE w o LI wv �a Add Elbow c,n S n ASaw� Z�'^�3 Add Coupling I t7 ti 12 ry�am Add Head 1 2 3 . I XDelete Head Vyy zF Cgzoo Move Head O iO Note:All revisions must be reviewed by Uponor u❑a❑m Uap1`C3 ianu Table F002-1 '''°"'.;.0 ',1z "" to Multipurpose Fire Safety Systems z ❑`-=<° _o-❑❑zaz s-u The Uponor Residential Fire Safety System is a residential fire protections ce m o a o<'�P"><¢ system Installed in combination with the cold side of the domestic potable W ❑ 'o 9 y i°z°z ,o F, water system. Only licensed contractors trained by Uponor can install this °_ ¢a nZ 5< y y system. 141V6. WP4 3 ¢"'' a V a awu�`�"y¢ What to do if Changes are Required y�4W��❑ >0'❑O��u oz•,u zz _y 1 If any features or obstructions require the addition or deletion of sprinkler 0 z o a < heads,or significant relocation of spnnkler heads,contact the Uponor Design 0,-........,,,..20v)0_Su` =.;5 n a''5FZ 5,�❑,O. ,E, Department to determine if observed changes require a redesign x ❑ N <m (888.594.7726). _ _ _ ♦ 4. 0.. n2,1' .'2?-,' � I } ps } j i r { I 'hi F'� ?amca.❑e,a xu ?za 1 7 0 5-0 x0X 20A FLOOR.ABOVE -'Z' i z �. y ?1—\1,1.1 EGRESS p6 'z °i m' O — 1-0 6-01F OVER L 2-9 5-4SH WOOD TREAD,MAX.RISER 8" o v o ° ❑ o LJ I ( 6-0 6-f0 SGD SWUM-Gm-NO-1 (ADD OR REMOVE STEPS AS m�h o y w u 1 REQUIRED PER SITE CONDITION) 3'_0" `y❑9.m F,;�° mz"-'� F aa�ox�_o�,m FLQQR BROW TV NICHE R3 CCUP. N z y z 3 z c INSULATE FLOOR 0 /® -�I n {, e F y S x o z a o`' x""< AT+36" ! --�1--- Si5.1 MAIN SHUTOFF •EPLACE 1' a 4 OVER UNHEATED I DIRECT a u o S z o o z � SPACE `--A.F.F. VALVE LOCATION • • ABOVE _KO -16 2.6 WALL W/R-21 BATF INSUL. n °� 1 I WATEF m R.iS'ED CEILNG FACTOR�''BUILT -, •SELF-CLOSING — _—__ H. +9.--A"ABV,. DIRECT-VENT GAS HFIEPLACE -'I I - WWW 20 -,--- s r� ,IuaFR cC (� I VENT UP THRU LO ROOF it (PER TRUSS MA UR 0 I 4 C 1-'/."AquaPEX TO Tandem 2-Car �SG'7! FURN. �DIREC �r D7 TILE HEARTH N IL; D4 E jC FURNF NetaStee,Bedr4 01 I OPTIONAL ttT SYSTEM H.11 ROOF Garage RADON there by certify that this plan,specification, IA i a '® INSUL.I FLOOR JOISTS OOF RAFTERS J [BELOW r : PANCY" i." REDUC or report was prepared by me or under my ,8 ' SYSTEI direct supervision and that I am NICET Q A7�F/P ENCLOSURE WALL FINISH - Certified at Level IV. N UrQ A RC-RES-160 I GWB CEILING FINISH I p [__.5 N 5'-5}•`4 - 3'-3y' 3 713f4 m 2' ' INSULATE FLOOR OVER' 'Wing I 1 C1 4 - L 54"TYPE'X'GWB FURR '9�J__— 1 4_1. RADON UNHEATED SPACES -- - -. - n RADON( �rIR.E�T,APE ALL FOR DUCT RUN 5, ' T.17 RC-RES-1 _II,i REDUCTION " IOY I REDUCTION /�^'tl r+rA I, LAO' I Brent D Kotula SYSTEM 2'-B" 3'-I pi ,r2:" 2' 2 3'-10" I'-II'®c, SYSTEM BELOW CEILING U ER STAIRS _•.� 1 r "� �PIT m LEVEL. INSULATE - AND LAND( I 2 Date: Reg.No.113889 CCT`. �f ` FLOOR ABOVE. / I I V I Ank 1 5 SH1 '122- 1 , ■ 7_,_ 1"AQUAPEX INTERLEVEL i �' -j2-, i Z=' - - // / • 3 I I y 4'-1° D1 81FOLD 10'Q CONNECITONS FROM SECOND I I / /BSO TE WALLa ��gt��� 7 FLOOR TO THIRD FLOOR � M,26 �" _ \3 PER DETAILLLo i x4 FLA ^�• PLANT•".� " / \ i___� •2 r' �•�4•ES � _� / / WHERE ADJAER7 RADOt` _6- _ 24'78 m�2 T(J • ES-16 t,a•�� II / I � f n / �1-�70 HEATED SPACE ��__ REDUC 11nSYSTEI B. h SHELF N�.1 2r6' �� v / i SEE- m.1 O(� • L'_•�F(e` 'P" W 1"AQUAPEX INTERLEVEL / q� U4 F( f E It lot �. f • \f!h '1" LVO/WALL AT ,,CONNECTIONS FROM FIRST FA i T.33 I / T J`.t - \ DETAI, a=o r - +42"A.F.F. FLOOR TO SECOND FLOOR \ \ t_ -0- o o.a I I - ...Ail ' I I. • ' a �,., WOOD ODD ORE RfiMOVE SRTEP��B" i'� II 16 e z z n C,zll 0 6 f. RES 149 _ _ _ / ( AS D5 < m v I r 1 , •� ©. p YrT F. t // \UIRED PER SITE CONDITION _ LJJ r / Lr OPEN 70'B„,,, � II ©RyYSTEM SEE SI-/ \ , RC-RES-16I�`i J \r 5< W ,:_11-1-1 H f r t� U4 1 iI.',c! —; �I ( T.. Q T j '.35 Entry =2 - o s&P Y LAD .,,C-RE '� i �I ` LNC LLJ 111D,:,0<Z 0 ~ 07� o A ' • i M f z o a, !L A, 42 w �I<_ �e" //_ I' _ F. Z N °°uaavw�izo \T� 6-0 BIPA___ u n WOOb Z -'� 18 ~a < ILL...LLLN N O 0 I '-- 9 ,® -•I" GWBTTHROUGH FURRI, MN D4) I I`w` M CC Ns w LL t1 s 6._t 1II TYPICAL j �® �. ge rl TYP. 7RC-RES-18 I I—� LU 1 j im i Tech Rm. Ely �' jJ4_ ' .Q6-G7D SD� ii_i� e _ Pwdr. —H FI INSULATE I7\ room 2e e j uNH® R{3 �� j `� 3' r1 Yz Y 1 Q (� FLOOR ABOVE ' r AT Q w LU m¢z ru I m a>•� _L__.„_ FLOOR BELOW-<------'1' I STEPS "" m',`..*-1F.,, m v 65 2-6 6 SH 2-6 5-E SH rc g5 �� EGRESS F j / > H •+ y g ru 7-0 5-0 SOO 7-0 5-0 UN1 LI r r 1 I in' m /i In j I ROOF I n I I I T I I I1+ 3,g_3ugga i roost a z 12 3 THIRD FLOOR --2 . SECOND FLOOR FIRST FLOOR t T- LLSHEET DESCRIPTION MIRROR Fioi 1411 = 11_011 F10 1411 = 11_011 Flol , 1/4" = 11_Ou SHEET NUMBER 2 .. 5 0 5 15 'v Imo _ __ _ t O c UPONOR - CONFIDENTIAL F101 ,.. U r • A uaSAFETM GENERAL NOTES' Senju RC-RES:Open Web Truss/TJI Construction InsulationIn areas eeasu �Recommendations ce ould be taken In unheated attic spaces See General Notes 8"2"5"7 for Architectural Q • ProPEX LF Brass Fire Sprinkler Adapter Tee shcover Uponor deD:tubing insulation with insulation.frer. ee n Feature Requirements Pshould follow the guidelines of the insulation manufacturer. See Uponor T z f 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic r ' /� O W 8 SECTION 3.3.11.3. Required.If - �h-on Nut Installation guidelines(Provided in Contractors Documents package or online "/Y///// ft H Blocking is Used, Is ' 1�"Min. at www.Uponorpro.com). -,„o 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Use The 2 Top IF =noTHIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND UA1 "Max. p UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Strew Holes. )• t Bolcom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. C a-'R p If no adtlitinal floor area is created No Additional Sprinkler Is Required. ^°G I racket t°Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or a m w¢ 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adayter , - other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less L O 17:2:T)u RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket I the recommended extreme weather installation instructions to isolate and +I W u PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE l �--�- I protect system components from extreme temperatures. Because this I RGRES-16 I d v N z SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE ,'� /// • B�\ / system also delivers domestic cold water directly to plumbing fixtures, 9'-0"or less ,,,,,II k",,,,,,' z a SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 11/2',' ¢ },, i Uponor highly recommends that you protect the tubing with adequate ,',E Full Courso i L insulation in warm weather areas to minimize heating of the cold water o u o m 5 .w 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Sa�ews supply w ft°;0 3 NFPA 13D 2016 EDITION. In Bottom jliWes! �� 0 / 2''''',_.: 'i Installation methods include,but are not limited to: 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. -� E.,`'',','°r w 3 " �y • Tenting over the fire sprinkler piping. 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free flat- .. r" ` • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft,be more than 2'-0" Concealer Senju \. Concealed Flat Increased depth of blown-in Insulation. deep,more than 9'-0"wide and be with in the coverage area of the Alo= '' DAMAGED MUST BE REPLACED. P e Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. o z z e z h F m m ��� °p 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to z�o E'o a x 3 protect all components during application.Consult with the spray foam a x?o F`-'o p m 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5"5.3 Distances From u L. a�>z ❑ a o i P tY P -z�„ aym° Heat Sources ffo_ffSfH`oms 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Consultation with local building officials is encouraged to ensure compliance r - m m a-x -�c WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND d a o m o 7 cmi u PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LlI,B ass.Fire �` ' $$,, with local building codes. Ordinary Intermediate S° 8..z z=c 3 s a AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler a ter T///r Fl sKron Nut r Adapter Heat Source Temp. Temp. °z °oo d FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM �' // I 135°-170° 175°-225° R2,",2,-,:."1 '4.g'2.o m 0 y o WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE '� Bendln PEX Tubin 36" 12" z' o a o▪ft_ THIS SIGN". / !, g g Side of Fireplace W g°o°za o Q�o o a z } -( 1>✓ Mn The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" W'm p m $o Fz i 3 a 1 z Max. the outside diameter(6 x OD). 42•• 12^ I° z a 5 z p 10.ALL INTERIOR PIPING TO BE UPONOR"AquaPEXp"UNLESS NOTED. Wood Burning Stove - t••r a°.F y Are Sprin ler7Ydap)et - � s tt race or muss Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Kitchen Range 18" 9" Q a z e_o z o o z ' ra kit-to 11.UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket' `_-�- tubing to facilitate 90-degree rigid bends. g J z z 9 n y x y�'d y /' Wall Oven 18,• y, V a e�..� ¢ / `�� 18^ g•• y uN`'oz°u'zz°y<mC 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2"/• } Recommended Tubing Length Between Fittings Un Hot ir Flues sHeat Ducts , m o z , z LL Z: z,,m BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Cour / 18" 9" CI m-. RESTRICTIVE SPACING LIMITATIONS. Thread S re/<.� a ft ft's u o r T Fitting Size Minimum Tubing Length u 1-f i�` Uninsulated Hot Water Pipes 12" 6" - ❑o N S o a H m In Top H es L_j 3/8"ProPEX Fitting 2^ 2 a G'2 y z u o!R 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING �,' Side of Hot Air Diffuser 24" 12 a g_I p i,ft a a MOUNTED OBSTRUCTIONS. '/ 1/2"ProPEX Fitting 2 1/2" Front of Hot Air Diffuser 36" 18" g ° 2 a m 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3 o 0 0 9 o j y o y 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Lead-Free,Fief, 6^ 3^ 4.,Ii r;�• A t o SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Concealed ben u \• _.. ' - 1"ProPEX Fitting 4 1/2" Furnace _ o o z m m a ft u U y J Concealed Flat 6^ 3^ o m Sprinkler Head 5OW-250W Light Fixture _, y s y_o y m _ P Cover Plate 1 1/4"ProPEX Fitting 5 1/2" 25OW-499W Fixture M ft u s ft O P o',u z 2 z z u o. 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN12" 6" CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS Light3 m S t°a 3 THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ ft 9 ft 2 o z a o z aL m 9 ft w I auu_�Fo'�a 16.NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. \ N Uponor flings ar T"tubing(white)and ProPEX'"EP Fittings and ProPEX'" • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Brass Fittings are approved for exposed installation where the following THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FP PER SPRINKLER. conditions are met.(UL 1821 Approved) • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY _ WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: - '.m /r)1170:O (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. n m ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open r5::= °m I here by certify that this plan,specification, (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. I (D or report was prepared by me or under my SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). direct supervision and that I am NICET (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT(1.7 M) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. Q❑ Certified at Level IV. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ \I - THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55" L XI 1.66" ALONG THE FINISHED FLOOR. are used. �I 1 Brent D Kotula c THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation in 3o Hanger 1" Hanger() 2 d 9 9 Date: Reg.No.113889 PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER Tubing Support Spacing: SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. E tr (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. Enough togAllow the Tubing to Expand andt �rt the Tubing,Yet Relaxed Contract)ARCHITECTURAL FEATURE. 2. Do not use supports that will damage the tubing.Inspect metal supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are T 5 17.NFPA 13D 8.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor AquaPEX'"tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. y • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each THROUGH 8.3.8. Floor and at a Mid-story Guide. 0 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT°(5.1 M')AND LESS m 4 o • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT " MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test f=c (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M'). The In-line Flow Test can be constructed on site. It performs a flow test to a.o$ c 04 (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE High Upstream Pressure ensure proper system operation and flow(see Figure FO01-B). r j r^ F_, MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. If the upstream pressure exceeds 80 psi a pressure reducing valve may fft w -• n v • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND need to be installed. Some jurisdictions may require a pressure reducingro Q 0 mo rima v SIMILAR STRUCTURES valve regardless of upstream pressure. Uponor AquaPEX < F-`�,ti • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE Tubin j W W f, EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND t CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, g 1-1/ z 0 z CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING LLJ w N PURPOSES. ,, ;1 ___ _� _- .. .. 0 w • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR _TT! - _ V Li z bj cJ¢6 a F AR: I aFaazow >_ • U IT,.1.00 SPRINKLER PROBED ION SHALL BE BEQUIR OR IN THE CONCEALED HEC ONCE LEVE SPACE. UPIED AREAS O THE �� /-J�- -- W M 0 O-8?2,i m w • 8.3.5.1.1 WHERE THE FUEL-FIRED Q ''�^1 WHE EQUIPM S AS u Male Threaded Coupling ProPEX Fire V/ N U V s¢a z0 0 m DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE ��'' Sprinkler Adapter N N 0 INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIREDr. EQUIPMENT FROM THE OCCUPIED SPACE. Ir -- 1"Ball ValveCe 0 • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT -- --To Hot Water Heater Male Threaded Coupling - 7"I ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. y Female Threaded 1 rye • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING 2 E "' Tee with Water H '--i l+ z g 3 CONDITIONS: v Pressure Gauge O O 1 w (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED g '" 0-- Pressure Gauge Sprinkler Orifice _W- (Optional) - ,'O.,w~O E ` 100 FT°(2.83 M3). t t^ IEQ c° x H (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS '" _ 1 ` f z m c it AT THE LOWER CEILING ELEVATION. y i_ Main Fire Sprinkler Flow Testto W °`a z 2 (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE c _ .--Shut-off Valve To ensure the system provides enough water for proper fire sprinkler W ry -+ m,:,_-1`:9 67, TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. 'n1 performance,you should conduct a flow verification test. < (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M')SHALL BE PERMITTED TO HAVE A PLASTIC COVER. _ LL IIr. Uponor Warning Signs > H '`" i ft C ru r ^ • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS o l o„j Note: The NFPA 13D Installation Standard does not require flow 11 (9 1°':,',41.E' >m O m 0§:w c.e (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR I. verification. Z I_,1 a 3 LL ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED �, ,Y,3 w a a as Pressure Reducing Beforeperforming a flow verification test,confirm the water pressures by PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. o ri • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING c i O Valve contacting the Water and Sewer Department of your local city. Ensure the E p ly O z 24 EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. o - available water pressure matches the pressure used in the system design. F 18. INSULATION GUIDE LINES PER NFPA 13D.I. c ftSHEET DESCRIPTION Note: The sprinkler plan indicates the most hydraulically remote sprinkler • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE •- (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS u • USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY ¢ your local code. INSULATED TO MAINTAIN 40°F. rn •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea atnotify the fire ay speector at least inspection hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER O SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in i CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Contractors Documents package or online at www-Ups com)for a Troubleshooting. PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. , (__. more lIf there Setup, ons please Performing inontattg theUponor. and Li ,80 psi © UPONOR - CONFIDENTIAL FO 0 1 17- PRV Set Pressure