Loading...
Plans (33) • OFFICE COPY _m ".1",; -,:.T. � ,, —A+• -- LIZ *� ....-- -- Z: �w L -o-.,- = ..* rmuav tl'65685' .= tY-Z amu- ZZ Z1- \ O� H1 I ., awn swtia svrm ..._ •._... ..,s .:: isuv.11 L'LV vam ..�;,. .: aau s LI' ccwra ... ,!//1� EXISTING OVERHEAD �' o SPRINKLER LINES `� EXISTING 6" MAIN i = ki 3 0 \ GENERAL NOTES w •- q n CM(OF TIGARD d \4. 1. WESTERN STATES FIRE PROTECTION(WSFP}SCOPE OF WORK IS A TENANT pi ° REVIEWED FOR CODE COMPLIANCE IMPROVEMENT IN AN EXISTING COMMERCIAL SHELL SPACE.ALL EXISTING PIPING j y ^ TO REMAIN. NEW PIPING AND UPRIGHT SPRINKLERS TO BE PIPED FROM EXISTING i�' F Approved: f] PIPING USING A MECHANICAL TEE. 0C: [ I 2. ALL NEW PIPING TO BE SCH.10 OR SCH. 40 BLACK STEEL WITH GROOVED OR TIE INTO EXISTING�', THREADED FITTINGS. Pc'mit#: f P SZQ1-'- 00 1 q 2 6" MAIN W/ , 3. ALL NEW MATERIALS TO BE NEW AND UL LISTED. 411118 Address: )1+1(10 7a1.1 d v MECHANICAL TEE 4. PAINTING OF PIPE AND PROTECTION FROM PAINT IS NOT IN CONTRACT. c 5. OWNER IS RESPONSIBLE TO PROVIDE HEAT AT ALL TIMES WHERE WET PIPE St) to t$: 00 " N 1 la SPRINKLER SYSTEM IS INSTALLED 6. FOR CLARITY, HANGERS ARE NOT SHOWN ON DRAWINGS BUT HANGERS WILL By r - ) }- Date: jar )-1,- )-3BE INSTALLED PER NFPA 13. SECTION VIEW SYSTEM DESIGN CODE: FULLY SPRINKLERED PER NFPA 13, 2013 ED., AREA OF WORK—-_� SYSTEM TYPE: WET �d N SPRINKLERS: QUICK RESPONSE 1 s DESIGN CRITERIA: LIGHT HAZARD CITY OF _F.IGARD .. N ti. _ �_ � 3III DI I DIVISIOQ �r _ DRAWING LEGEND -o f - 3 g '-6 t'-� 3'-6 -- 3'-6 =1''-3---4. - 69,2- 1-3 3,- II � 44 6`" 6-" 14 DENOTES PIPE HANGER 4. XQ DENOTES NODE POINT ao785p °° ���.4 )� iiir - ��` ; _ � � '� � �' _°' *1'-0 FF t DENOTES DISTANCE ABOVE FINISHED FLOOR =aaaaaa __ _ _. .._ I--I _ : OREGON 4, T } 4' 8= 3'1 -3'=9-175— E-14 m0 �ti t , o i �. ,_,0� Water Supply o F 30,20 �� _ I a � i I+ , it , I► , m Static Pressure: 105 psi SAMMY SCREW IN EXPIRES: 4?`7I( , +» . 1~ Residual Pressure: 98 psi WOOD JOIST a z N 1680 GPMN — �_ � �. FlowRate: o a z zs CO g �o N CS cn" Hydraulic Information Sprinkler Legend 2X Solid OCCUPANCY CLASSIFICATION Light Hazard Wood Joist c g Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temp l '�► ,� e h DENSITY 0.100gpm/ft2 for 1500.00ft2(Actual 873.37W) 0 Reliable RA1425 F1 FR 13 5.6 Upright 1A Quick Bronze 200°F 4 o TOTAL HOSE STREAMS 100.0 Total = 13 TOTAL HEADS FLOWING 12 All K-FACTOR 5.6 Thread Sammy a Rod 11111111 GST 20 TOTAL WATER REQUIRED 313.6 CONTRACT NUMBER: a n Pipe LG1837TOTAL PRESSURE REQUIRED 68.25 S r■ 11kIer P Ikiiiw\ DRAWN BY M St adelman Swivel of RISER (gp ) 313.6 DATE -01-17 Ring SCALE BASE of RISER(psi) 68.25 1/8" = 1'-0" SAFETY MARGIN (psi) +36.44 (34.8%) SCALE: 118" = 1'-O" � ' cOPY \��/' FLOOR/AREA: OFFICE SHEET NUMBER FP-1