Loading...
Report (30) Af�w/? - 009?S 4 1 2,S 5 S S Gr/ (1V(- /4j OFFAL 1 PY GAS FURNACES ( !Eii1ü1) ? , , z , z E . ., . , . Upflow/Horizontal PRODUCT SPECIFICATIONS Bulletin No.210590 November 2017 Supersedes January2017 DEC $ 2011 vo - 1yrrwii- !i,..-;.;-,1 w4a & R t. y„. ,_ ar 4 , . ((EED A. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons MODEL NUMBER IDENTIFICATION ML 180 UH 070 XP36B Unit Type T Cabinet Width ML=Merit Series® A=14-1/2 in. B= 17-1/2 in. C=21 in. Stages 1=Single-Stage 1 D=24-1/2 in. AFUE 80=80% Nominal Add-On Cooling Capacity 24=2-2.5 tons 36=2-3.5 tons Configuration 48=4 tons UH=Upflow/Horizontal 60=4-5 tons Nominal Gas Heat Input 045=44,000 Btuh Blower 070=66,000 Btuh P=PSC Multi-Speed Blower Motor 090=88,000 Btuh 110=110,000 Btuh t Low NO. 135=132,000 Btuh X=Units meet California Nitrogen Oxides standards 'Indoor coils with the same letter designation will physically match the furnace. i. FEATURES CONTENTS - a � 0:„ Blower Data 14 r--------------#:;,,,w,,,,4-4:=4:,... .,., , Dimensions- Furnace/Coil Combined Dimensions..13 Dimensions-Horizontal Position 11 , Dimensions- Upflow Position 10 4.' _ 11 ' Features 2 3 Gas Heat Accessories 8 " High Altitude Derate a ':14.1 '1 Installation Clearances 9 Model Number Identification 1 lU Optional Accessories 8 ' ?+ Optional Accessory Dimensions 12 \ f' Specifications NOTE-MLI8QUH FURNACES ARE NOT AVAILABLE IN CANADA! WARRANTY APPLICATIONS Input capacities of 44,000, 66,000, 88,000, 110,000 and DuralokTm Aluminized Steel Heat Exchanger-Limited twenty year warranty in residential applications,ten 132,000 Btuh. years in non-residential applications. Energy efficiency(AFUE)of 80%. Limited five year Compact cabinet for upflow, horizontal-left or horizontal- All other covered components -warranty in residential applications,one year in applications,one year in non- right applications. residential applications. Utility room, alcove, closet, crawl space, basement or Refer to Lennox Equipment Limited Warranty certificate attic installation. en included with equipment for details. Lennox add-on indoor coils, high-efficiency air cleaners APPROVALS and humidifiers can easily be added toi furnace. Units are Certified by AHRI. Shipped factory assembled with all controls installed and wired. Units tested and rated according to US DOE test Ready for installation in upflow or horizontal right-hand procedures and FTC labeling regulations. position without any modifications. Horizontal left-hand "X" models approved by the California Energy position requires repositioning of pressure switch. Commission and meet California Seasonal Efficiency Removable bottom seal panel shipped in place for side requirements and California Nitrogen Oxides (NOx) return air is easily removed for bottom/end return air Standards. applications. ISO 9001 Registered Manufacturing Quality System. Each unit factory test operated to ensure proper Blower data from unit tests conducted in Lennox operation. Laboratory air test chamber. ML180UH/Page 2 FEATURES HEATING SYSTEM Q Flame Rollout Switches (2) Manual reset switches are factory installed on the front 0 Lennox DuralokTM Heat Exchanger Assembly Heavy gauge aluminized steel heat exchanger. of the burner box. Switches provides protection from abnormal operating Crimped seam clamshell type design. Designed for normal expansion and contraction. conditions. Minimum resistance to Limit Control air flow. Automatic reset, primary limit is accurately located on Heat exchanger has vestibule panel on all units. been laboratory life ;Optional Accessories cycle tested in excess of industry standards. High Altitude Pressure Switch Kit Required on most units for proper unit operation at Compact size of heat altitudes from 4,501 to 7500 ft. _;. exchanger permits low overall design of furnace Natural Gas to LPG/Propane Conversion Kit cabinet. Required for field changeover from natural gas to LPG/ ® Inshot Burners Propane. Aluminized steel inshot burners provide efficient, LPG/Propane to Natural Gas Conversion Kit trouble-free operation. Required for field changeover from LPG/Propane to Burner venturi mixes air and gas in correct proportion natural gas. for proper combustion. Vent Adaptor(Upflow Applications Only) Burner assembly is removable from the unit as a single Allows venting through a component for ease of service. masonry chimney without the (�2imm�'I ®SureLight®Hot Surface Ignitor need of a flue liner. Tough, reliable, long-life,trouble-free performance. Manual reset temperature IV Silicon nitride ignitor. sensor protects against it 7m. abnormal operating conditions. 178 mm) Cemented to steatite block for protection against current leakage. Sensor wiring may be routed t Ignition leads are constructed of nickel plated copper from either side of adaptor. + and are enclosed in high temperature Teflon®insulation Minimum winter design for dependable operation. temperatures: -10°F when used with interior masonry chimneys. 0 Gas Control Valve +5°F when used with exterior masonry chimneys. 24 volt redundant combination gas control valve combines manual shut off switch(On-Off), automatic Refer to Winter Design Temperatures Map on page electric valve(dual)and gas pressure regulation into a 6 for application information.Also refer to the compact combination control. installation instructions for detailed information. ®Combustion Air Inducer BLOWER Shaded pole heavy duty blower prepurges heat ®Multi-speed direct drive blower. exchanger and safely vents flue products. Statically and dynamically balanced. Pressure switch proves blower operation before Resiliently mounted. allowing gas valve to open. Blower assembly easily removed for servicing. Operates only during heating cycle. Blower speeds are easily changed on the integrated Direct access allows inducer assembly to be rotated furnace control. See blower performance tables. 90°clockwise or counterclockwise to facilitate easy vent attachment in horizontal applications. ML180UH I Page 3 FEATURES ®CONTROLS Night Service Kit SureLight®Integrated Furnace Control Contains most commonly used service parts: Contains all necessary controls and relays to operate • Furnace Control furnace. • Ignitor Combustion air inducer is controlled by the integrated • Flame sensor furnace control. Prior to ignition, a pre-purge cycle • Gas valve for 15 seconds is initiated.After the main burners are . Transformer turned off, a post-purge cycle for 5 seconds is run. Flame sensor assures safe and reliable operation. Universal Service Kit-Switches Should loss of flame occur,flame sensor controls will Kit contains: initiate 4 re-attempts at ignition before locking out unit • Primary limits (for each model) operation for 60 minutes. • Pressure switches (for each model) Watchguard type circuit automatically resets ignition • Flame rollout switches (for each model) controls after one hour of continuous thermostat • Secondary limits (for each model) demand after unit lockout, eliminating nuisance calls for service. Optional Accessories Fan control consists of adjustable blower timed-off Air Filter and Rack Kit for Horizontal Return Air delay(60, 90, 120, 180 seconds-factory setting 120 (End)Applications seconds)and fixed blower timed-on delay(45 seconds). Washable or vacuum cleanable polyurethane frame For air-conditioning applications, blower is automatically type filter and external end return air rack available for energized on thermostat demand for cooling. field installation. Integrated furnace control has one red LED to indicate Rack has filter door for easy filter servicing. status and indicate diagnostic codes. Push button recall Flanges on rack allow easy duct connection. of the last 5 diagnostic codes aids in troubleshooting. Integrated furnace control has built-in twinning capability See dimension drawing. ("TWIN"terminal on control)to operate two furnaces Air Filter and Rack Kit for Upflow Side Return Air simultaneously without any additional controls.A field Applications-Not for use with Return Air Base supplied isolation relay is required to operate the Washable or vacuum cleanable polyurethane frame twinned (no thermostat connection)furnace. type filter and external side return air rack available for Two accessory terminals furnished for additional power field installation. supply requirements for 120 volt(less than 1 amp) Available in single and ten pack kits. power humidifiers and powered air cleaners. Rack has filter door for easy filter servicing. 24 Volt Transformer Flanges on rack allow easy duct connection. Furnished and factory installed on outside of control Field installs on either side of unit cabinet. See box. 40VA transformer has fuse wired in series. dimension drawing. Field Wiring Make-Up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed on right side of furnace. Optional Accessories Thermostat Thermostat(programmable/non-programmable)is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. ML180UH I Page 4 FEATURES CABINET Optional Accessories Low-profile, narrow width cabinet allows easy Horizontal Suspension Kit installation. Provides suspension of unit and indoor coil in horizontal Heavy-gauge, cold rolled steel construction. applications. Pre-painted cabinet finish. Allows complete service access. Flue outlet on top of cabinet for upflow applications, Consists of corner mounted hanging brackets with can be relocated to either side of cabinet for horizontal vibration isolators, return air end support rail and applications. hardware for assembly. Flanges provided on supply air opening for ease of Metal hanging straps must be field provided. plenum connection or alignment with indoor coil. ® Insulated cabinet with foil faced insulation on sides and Return Air Base back of heating compartment. A field fabricated transition or Return Air Base is required when using an IAQ product higher than 14- Complete service access. 3/16 in. installed next to the unit and serviced from the ®Safety interlock switch automatically shuts off power front. IAQ products higher than 20 in. require a field to unit when blower compartment access panel is fabricated transition. removed. Base must be used for 60C and 60D models with air Gas piping and electrical inlets are provided in both volumes over 1800 cfm in upflow applications when sides of cabinet. only one side return is required. Return Air Entry: Cabinet is shipped flat for easy field assembly and is For bottom/end return-air entry for upflow/horizontal pre-painted steel to match the furnace. applications, remove furnished bottom seal panel from See Dimension Drawing. cabinet. High Performance Economizer For side return-air entry(upflow applications only), (Commercial Applications Only) corners are marked on either side of cabinet for return Designed for applications requiring outdoor air to be air cut-outs. utilized in a commercial HVAC system.Allows the See dimension drawings. entry of fresh outdoor air for free cooling, reducing the NOTE -60C and 60D size units that require air requirement for mechanical cooling. volumes over 1800 cfm must have one of the Heavy gauge galvanized steel cabinet lined with thick following: fiberglass insulation. 1. Single side return air with transition, to Mixed air sensor, outdoor air sensor and 24VAC accommodate 20 x 25 x 1 in. cleanable air filter. transformer furnished. Required to maintain proper air velocity. Approved for California Title 24 building standards. 2. Single side return air with Optional Return Air ASHRAE 90.1-2010 compliant. Base See separate Product Specifications bulletin for 3. Bottom return air. additional information and available control and sensor 4. Return air from both sides. options. 5. Bottom and one side return air. FILTER (not furnished) See Blower Performance Tables for additional Filter and provisions for external mounting must be field information. provided. Coil Match-Up All furnaces exactly match Lennox cased upflow indoor coils and horizontal indoor coils with same letter designation (A, B, C, D) in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. Lennox uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See coil bulletin for additional information. Low Leakage Cabinet All models have less than 2%air leakage and meet ANSI/ASHRAE Standard 193-2010 "Method of Test for Determining the Air Tightness of HVAC Equipment". ML180UH/Page 5 99%WINTER DESIGN TEMPERATURES FOR THE CONTIGUOUS UNITED STATES 5°F -10F 17°F "ar -WE 11191rr.. 27°F tilir , �' 5°F LT r.. � lili 'llr'. .. -10F 37°F W III OW _..„e i li b. lit 11641111",--A lib•- pia* .1\1 h, ',Ilk itITS,11111aWile". � 27°F '���� 37°F 111 This map is a necessarily generalized guide to temperatures in the contiguous Unites States.Temperatures shown for areas such as mountainous regions and large urban centers may not be accurate.The data used to develop this map was taken from the 1993 ASHRAE Fundamentals Handbook(Chapter 24,Table 1: Climate Conditions for the United States). Reprinted with permission from NFPA 54: National Fuel Gas Code 1999, National Fire Protection Association, Quincy, MA 02269.This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject,which is represented only by the standard in its entirety. ML180UH/Page 6 SPECIFICATIONS Gas Model No. MLI80UH045P24A ML180UH045P36A MLI80UH070P24A MLI80UH070P36A Heating Model No.-Low Nox -- ML180UH045XP36A Performance 1 --- ML180UH070XP36A AFUE 80% 80% o Input-Btuh 44,0008, 80% Output-Btuh 35,00044,000 66,000 0 66,000 35,000 54,000 50,060 Temperature rise range-°F 20-50 Gas Manifold Pressure(in.w.g.) 3.5/10.0 .15- 0. .53 - 0.60 .53 60 0. Nat. Gas/LPG/Propane 3.5/10.0 3.5/10.0 3.5/10.0 High Static-in.w.g. 0.50 Connections Flue connection-in. round 0.500 0.50 4 44 4 4 4 4 in. Gas pipe size IPS 1/2 Indoor Wheel nom.dia.x width-in. 10 x 7 1/2 1/2 1/2 Blower Motor output-h 10 x 8 10 x 7 10 x 8 p p 1/5 1/3 1/5 1/3 Tons of add-on cooling 1.5-2 2-3 Air Volume Range-cfm 345-1130 1.512 2-3 Electrical 650-1670 420-1160 785- 1660 Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 3.1 6.1 3.1 6.1 Maximum overcurrent protection 15 15 Shipping Data 15 15 lbs.-1 package 105 110 114 119 SPECIFICATIONS Gas Model No. ML180UH090P36B ML180UH090P48B ML180UH110P48C Heating Model No.-Low Nox --- ML180UH090XP48B Performance 1 AFUE 80% 80% o Input-Btuh 88,00080/o Output-Btuh 71,000 88,00071 89,000 110,000 Temperature rise range-°F 25-55 25,055 5 Gas Manifold Pressure(in.w.g.) 3.5/10.0 -10.055 25-55 0. Nat. Gas/LPG/Propane 3.5/ 3.5/10.0 High Static-in.w.g. 0.50 Connections Flue connection-in. round 04 4 0 in. 4 4 4 Gas pipe size IPS 1/2 1/2 Indoor Wheel nom.dia.x width-in. 10 x 9 1/2 Blower Motor output-hp 1/3 10 x 10 10 x 10 Tons of add-on cooling 2-3 1/2 3 1/2 - Air Volume Range-cfm 680-1795 4 3 4 Electrical Voltage 920-2160 910-2170 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.1 8.2 8.2 Maximum overcurrent protection 15 Shipping Data 15 15 lbs.- 1 package 131 183 151 SPECIFICATIONS Gas Model No. ML180UH110P60C ML180UH135P6OD Heating Model No.-Low Nox Performance , ML180UH110XP60C --- AFUE 80% Input-Btuh 110,000 80% 107,000 Output-Btuh 89,000 Temperature rise range-°F 25-55 3107,000 60 Gas Manifold Pressure(in.w.g.) 3.5/10.0 .5 - 0. Nat.Gas/LPG/Propane 3.5/10.0 High Static-in.w.g. Connections Flue connection-in.round 0 4 .50 04 in. 4 4 Gas pipe size IPS 1/2 Indoor Wheel nom.dia.x width-in. 11-1/2 x 10 1/2 Blower Motor output-hp 1 11 x 11 Tons of add-on cooling 4-5 1 Air Volume Range-cfm 1355-2715 4-2 Electrical Voltage 1380-2810 120 volts-60 Data Blower motor full load amps 10 hertz- 1 phase Maximum overcurrent protection 11.5 15 15 Shipping Data lbs.- 1 package 161 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 174 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. ML180UH/Page 7 OPTIONAL ACCESSORIES-ORDER SEPARATELY "A"Width "B"Width "C"Width I "D"Width Models Models Models Models CABINET ACCESSORIES Horizontal Suspension Kit-Horizontal only 51W10 65W75 51W1050W98 51W1050W99 51W10 51 W00 Return Air Base-Upflow only 10U53 10053 10U53 10U53 High Performance Economizer(Commercial Only) FILTERS 87L96 87L97 87L98 'Air Filter and Rack Kit Horizontal(end) 87L95 Size of filter-in. 14x25x1 18x25x1 20x25x1 25x25x1 Single 44J22 44J22 44J22 44J22 Side Return9 Ten Pack 66K63 66K63 66K63 66K63 Size of filter-in. 16x25x1 16x25x1 16x25x1 16x25x1 NIGHT SERVICE KITS 68W80 68W80 68W80 68W80 Universal Service Kit-Switches 89 IW19 89W19 89W19 89W19 Night Service Kit VENTING 18M79 18M79 Vent Adaptor-6 in.conn.size upflow applications only I 18M79 18M79 'Cleanable polyurethane,frame-type filter. GAS HEAT ACCESSORIES Natural Gas High Altitude Natural Gas to LPG/Propane High Altitude Input Pressure Switch Kit LPG/Propane Kit to Natural Gas Kit Orifice Kit 0-4500 ft. 4501 -7500 ft. 7501 -10,000 ft. 0-7500 ft. 7501 -10,000 ft. 0-7500 ft.11K49 7501 -10,00 t. 11K44 73W81 045 No Change 80W52 80W51 73W81 73W37 070 No Change 80W52 80W51 11K49 11K44 73W81 73W37 090 No Change 80W52 80W51 11K49 11K44 11 K49 11 K44 73W81 73W37 80W52 110 No Change 80W57 73W37 135 No Change 80W52 80W51 11K49 11K44 73W81 HIGH ALTITUDE DEBATE NOTE-Units may be installed at altitudes up to 2000 ft.above sea level without any modifications. At altitudes above 2000 ft,units must be derated to match information in the shaded areas shown below. NOTE-This is the only permissible derate for these units. Line Pressure-in.w.g. Gas Manifold Pressure(Outlet)in.w.g. Input 0-2000 Feet 2001 -4500 Feet 4501 -7500 Feet 7501 -10,000 ft. Minimum Maximum Natural LPG/ Natural LPG/ Natural LPG/ ' Natural LPG/ Natural LPG/ Gas Propane Gas Propane Gas Propane Gas Propane Gas Propane 045 3.5 10 3 2 10 3 10 3.5 10 4.5 11 13 070 3.5 10 3.2 10 2.8 10 3.5 10 4.5 11 13 090 3.5 10 3.2 10 2.7 9.6 3.5 10 4.5 11 13 110 3.510 3.5 10 3 9.6 3.5 10 4.5 11 13 135 3.5 10 3.5 10 2.9 9.6 3.5 10 4.5 11 13 1 Natural Gas High Altitude Orifice Kit required. ML180UH/Page 8 INSTALLATION CLEARANCES-INCHES(MM) UPFLOW POSITION B1 HORIZONTAL POSITION Vent Type T peType C Sides 0 0 � Vent Type T e B1 ( ) 0(0) Yp TypeC Rear 0(0) 0(0) IIIIIIEIIIIII ,2 2 ( ) Top � 1 (25) Rear 0(0) 0(0) Front��® 2-1/4(57) Top �0(0) ,0(0) Front(service/alcove) 24(610) 24(610) Front 2-1/4(57) Floor Combustible Front(service) 24(610) 24(610) Combustible Floor Combustible Flue 6(152) Combustible NOTE-Air for combustion must conform to the methods outlined in the National Flue�® 6(152) NOTE-Fu for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ANSI-Z223.1). NOTE In the U.S.flue sizing must conform to the methods outlined in the Fuel Gas Code(NFPA 54/ANSI-2223.1). NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-2223.1)or applicable current National Fuel Gas Code(NFPA 54/ANSI-2223.1)or applicable provisions of local building codes. Left side requires 4 in.if single wall vent is used on 14-1/2 in.cabinets,2 in.on provisions of local building codes. 17-1/2 in.cabinets. Line contact installation permissible between jacket top or sides and building joists. ML180UH/Page 9 DIMENSIONS-INCHES(MM)-UPFLOW POSITION 3-1/8(79) NOTE-60C and 60D size units that require second stage -r---,. m®� ®m •• air volumes over 1800 cfm(850 L/s)must have one too,�m n of the following: D ' 1.Single side return air with transition,to accommodate 20 x 25 x 1 in.(508 x 635 x 25 mm)cleanable air + filter.Required to maintain proper air velocity. / SUPPLY AIR 2.Single side return air with optional Return Air Base OPENING 3.Bottom return air. FLUE OUTLET m m m m m 4.Return air from both sides. 01111 5.Bottom and (Top) m m one side return air. no0 a m m See Blower Performance Tables for additional information. m m m m m mmmmm ', mmmmm 2 Flue outlet may be horizontal but furnace must be ....---- 1-N--3 OPTIONAL 1...I__23-314 ________� vented vertically EXTERNAL (603) s Optional External Side Return Air Filter Kit is not for use SIDE RETURN 25 with the optional Return Air Base. AIR FILTER KIT (635) (Either Side) TOP VIEW 3/4(19) 27-3/4(705) Front Panel 3-1/4(83) 9/16 E— A 3(76)Right 1(494)6 (14) B --el 9/16(14) 6-3/4(171)Left —���•m........• _ 2FLUE OUTLET L . ELECTRicALIN(EitherSide) -\ / 9-118(232)Right LET ' _ 1sOPTIONAL8-5/8(219)Lefte (Either Side) ®®aea®®aaa®a® EXTERNAL jl ®®®®®oo®a®Iii SIDERETURN ' aeae�eaeo�®Ba oc®®®®®®® c®® AIRFILTERKIT (Either Side) 5 318(137)Right GAS PIPING INLET 33 ' (Either Side) GfOD O=00 C C G=Ga (838) 2-3/16(56)Left 0 1 ELECTRICAL I 23 _I 1-1/2 INLET(Either Side) r (584) I (38) ,.. ar:) ..\ 14-314 (375) I Side Return 1416 Air Opening (356) (4 6) (Either Side) __I 1-15116(49) 5!8 3-1/4 23-1/2 3/4 (16) (83) (597) 3/4 I_ �— C �(19) Bottom Return (19) 1 �I� Air Opening Bottom Openingrn Air SIDE VIEW FRONT VIEW ■■■0■M■■3■■■©■� Model No. D ®®®®®®® mm ML180UH045P24A 330 4 3/4 121 ML180UH045P36A 14-1/2 368 13-3/8 340 ML180UH070P24A MLI80UH070P36A 159 ML180UH090P36B 17-1/2 446 16-3/8 416 16 406 6-1/4 ML180UH090P48B 203 ML180UH110P48C 21 533 19-7/8 504 19-1/2 495 8 ML180UH110P60C ® 584 9-3/4 248 ML180UH135P600 622 23-3/8 594 ML180UH I Page 10 DIMENSIONS INCHES(MM)- HORIZONTAL POSITION LEFT-HAND AIR DISCHARGE 1 Flue outlet may be from end but furnace must be vented vertically I I GAS PIPINGrINLET (Top or Bottom) 9-1/8(232)Top 8-5/8(219)Bottom I AIR ELECTRICAL INLET FLUE OUTLET FLOW (Top) (Top or Bottom) 3 76 1 —f- 06D 3/4(19) -t---�_ aTo--p—f- (171) �—� Front Panel --►I 5-3/8 op T (171) 2-3/16(56)Bottom 1.0_2(77-0357 FLUETOP VIEW (/1) O(EndET (838) 27-3/4 14 ) (705) 1 00000 �r p3/4 19) 9/16 19-7/16 00000 0000 0000 (14) (494) 00000 0000 0000] I mor 0000 0008 I 4-1/4 0000 0080 ® 23-1/2 SUPPLY B 0000 0000 (108) A 0000 000 AIR (597) AIR • + 0808 8000 8080 iiia 8000 0008 FLOW A OPENING I 0808 0808 C RETURN 0000 0080 AIR 00 a. D I 0000 0080 1 00 00 0000 0000 OPENING END VIEW �— - 3-1/8 FRONT VIEW END VIEW ) RIGHT-HAND AIR DISCHARGE 1 Flue outlet may be horizontal but GAS PIPING INLET furnace must be vented vertically (Top or Bottom) ELECTRICAL INLET FLOW (Top or Bottom) 6-3/4 FLUE OUTLET (171) (Top) 3/4(19) Front Panel j ` o __ 3(76) -2-3/16(56)Top 5-3/8(137)Bottom 8-5/8(219)Top TOP VIEW 9-1/8(232)Bottom ri 27-3/4 (705) 33 FLUE OUTLET 27-3/4 (838) (End) .43-1/8(705) ill I—T --- fir (79) 11 23-1/2 4-1/4 0008 8080 00 00 (597) 0000 0000 I D (108) 0800 0800 8 e0 19-7/16 RETURN 0000 8080 C A AIR 0000 0000 1 (494) FLOW 0008 0808 9/16 AIR 0 0000 0000 A SUPPLY B (14) OPENING_____________ _______j 0000 0808 00800 0008 8000 00000 AIR 0000 0000 08080 0080 0808 00000 OPENING 00800 END VIEW (19) 00000 -- FRONT VIEW END VIEW 9/163/4 Model No. ®11.11:®!�- D ML180UH045P24A ® in mm ® mm MLI80UH045P36A ML180UH070P24A 14-1/2 368 13-3/8 340 ML180UH070P36A 330 4-3/4 121 ML180UH090P36B ML180UH090P48B ML180UH110P48C 17-1/2 446 16-3/8 416 16 406 6-1/4 159 ML180UH110P60C 21 533 19-7/8 504 19-1/2 495 8 203 ML1801JH135P60D 24-1/2 622 23-3/8 594 IllEa 584 9-3/4 248 ML180UH/Page 11 OP1IONAL ACCESSORY DIMENSIONS- INCHES(MM) HORIZONTAL (END) FILTER KIT 1- 1/4 (3224-3/4 1 1 r 5/8 (629) (16) B T- 5/8Oil Furnace Catalog (16) Cabinet Number in, mm in. mm Width A 324 B RETURN B 87L9687L95 1814 457356 16-3/412-3/4 425 A AIR OPENING AIR FLOW C 87L97 21 533 18-3/4 476 5/8 D 87L98 25 635 23-3/4 603 (16) 23-1/2 (597) I U AIR FILTER 5/8 (Furnished) (16) SIDE VIEW FRONT VIEW Optional Return Air Base (Upflow Applications Only-For use with A,B,C and D cabinets) FURNACE I _00000000000® FRONT O I — , I IFSBADI I 23(584) 3-1/4f_ — Overall WITHOUT / (83) I (Maximum) 1 Mi1lnimu9m) I IAQ CABINET, 2 Maximum 22-7/16 INDOOR AIR A SINGLE Unit side return air 14(356) I (570) It 4 QUALITY RETURN AIR I I Opening l I Overall I II CABINET PLENUM ) L—J (Maximum) AIR FLOW (PCO,Filter MUST — Cabinet,etc.) COVER BOTH II — UNIT AND 4--- - SIDE RETURN RETURN 7 1/4 5-5/843) AIR OPENINGS AIR BASE (1 OPENINGS JI (184) Either Side N ——— 23 3/4 OPTIONAL (584) (19) 14-1/2(368)A Width(65W75) RETURN 26 7l8 17-1/2(446)B Width(50W98) AIR BASE (683) 21 (533)C Width(50W99) SIDE VIEW 24-1/2(622)D Width(51W00) NOTE-Optional Side Return Air Filter Kits are not for use with Optional Return Air Base. Both the unit rsdn it n air opening dimensions for units requi ng 1800 cfm or more of air(W x H):23 xd the base return air openg must be covered by a single plenum or A1111 in.(584 x 279 mm). The Minimum unit aideereair P imensions shown. opening r openings be u amust be cut incommodate thefield.There are cutting guides stenciled num or IAQ cabinet on the cabinet for the side return air Side returne furnace cabinet. opening.The size of the opening must not extend beyond the markings nth356 mm),is preferred. 2 To minimize pressure drop,the largest opening height possible,up to ML180UH/Page 12 DIMENSIONS-INCHES(MM)-FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION Model No Cased Uncased (C33 only) A B A B CX34 C35/CX35 C33 in. mm in. mm in. mm in. mm - -- 33-18A 12-1/`318 45-1/2 1156 9-3/4 248 42-3/4 1086 CX34-19A-6F --- C33-19A 16-1/2 419 49-1/2 1257 9-3/4 248 42-3/4 1086 --- -`- 33-24A 16-1/ 419 49-1/2 1257 14 356 47 1194 CX34-18/24A-6F 035/0X35-18/24A-6F \�/ CX34-18/24B-6F C35/CX35-18/245-6F C33-24B 16-1/2 419 49-1/2 1257 13-7/8 352 46-7/8 1191 j CX34-18/24C-6F C33-24C / CX34-25A-6F 35/CX35-24A-6F 33-25A 18-1/ 470 51-1/2 1308 16-1/4 413 49-1/4 1251 �j I'l � A CX34-25B-6F C35/CX35-24B-6F 33-258 18-1/2470 51-1/2 1308 15-7/8403 48-7/8 1241 / I / A CX34-306=6F 33-30B CX34-300-6F -- 33-300 20-1/ 521 53-1/2 1359 17-3/4 451 50-3/4 1289 • / B CX34-30A-6F . 033 30A 20-1/2 521 53-1/2 1359 18 457 51 1295 CX34-31A-6F 35/CX35-30A-6F 33-31A 22-1/' 572 55-1/2 1410 21-1/4 540 54.1/4 1378 • 33 ee., all /� ' , (838) CX34-31B-6F 035/0X35-306-6F C33-31B 22-1/2 572 55-1/2 1410 20-1/4 514 53-1/4 1353 >o !1V( CX34-36A-6F 35/0X35 30/36A-6F 33-3M 24-1/ 622 57-1/2 1461 22-1/8 562 55-1/8 1400 •, a CX34-36B-6F C35/CX35-30/36B-6F C33-36B 24-1/2 622 57-1/2 1461 21-7/8 556 54-7/8 1394 CX34-36C-6F 35fCX35-30/36C-6F 33-36C 4-1/ 622 57-1/2 1461 21-1/4 540 54-1/4 1378 • CX34-38A-6F C35/CX35-36A-6F C33-38A 24-1/2 622 57-1/2 1461 22-1/4 565 55-1/4 1403 CX34-38B-6F 35/CX35-3613-6F 33-38B 24-1/ 622 57-1/2 1461 22 559 55 1397 CX34-426-6F --- C33-428 24-1/2 622 57-1/2 1461 21-7/8 556 54-7/8 1394 CX34-438-6F 35/CX35-4813-6F 33-43B 27-1/4699 60-1/2 1537 26-1/4 667 59-1/4 1505 CX34-43C-6F 35/0X35-480-6F allEarairiS 699 60-1/2 1537 25-3/4 654 58-3/4 1492 --- -- C33-440 24-1/2 622 57-1/2 1461 21-1/2 546 54-1/2 1384 0X34-44/486-6F --- C33-48B 24-1/2 622 57-1/2 1461 22-1/8 562 55-1/8 1400 CX34-44/480-6F - 33-480 r4-1/ 622 57-1/2 1461 21-1/2 546 54-1/2 1384 CX34-49C-6F C35/CX35-49C-6F C33-49C 9-1/2 749 62-1/2 1588 28-1/2 724 61-1/2 1562 CX34-50160E-6F 35/CX35-50/60C-6F 33-50/600 699 60-1/21537 24-3/4 629 57-3/4 1467 CX34-600-6F --- C33-600 321Pi3 648 58-1/2 1486 24-3/4 629 57-3/4 1467 CX34-620-6F X35-60C-6F 33-62C 1-112 800 64-1/2 1638 30-5/8 778 63-5/81616 CX34-620-6F CX35-60D-6F C33-62D 29-1/2 749 62-1/2 1588 28-3/4 730 61-3/4 1568 HORIZONTAL POSITION Model A I B Number in. mm in. I mm CH33 CH33-18A-2F 21-112 546 54-1/2 1384 B-<--------------14:93CH33-24/30A-2F, CH33-428-2F, 26-1/2 673 59-1/2 1511 (838) CH33-36A-2F, CH33-48C-2F, A CH33-36B-2F, CH33-60D-2F r/ 2* CH33-36C-2F, CH33-44/4882F, CH33-62D-2F 31-1/2 800 64-1/2 1638 /i =dist„. 11111 CH33-50/60C-2F, // _ \� CH35 C N i;e I 000�o CH35-18A-2F, CH35-36A-2F, 26-1/2 CH35-24A-2F, CH35-36B-2F, 673 59-1/2 1511 ue�� ---''cI 111 CH35-2413-2F, CH35-360-2F, ,aooa ��'I,; CH35-30B-2F, CH35-42C-2F, CH35-48C-2F CH35-30A-2F, CH35-51C-2F, 31-1/2 880 64-1/2 1638 CH35-428-2F, CH35-60D-2F CH35-48B-2F, ML180UH/Page 13 BLOWER DATA ML180UH070P36A PERFORMANCE(Less Filter) ML180UH045P24A PERFORMANCE(Less Filter) Air Volume/Watts at Various Blower Speeds External Air Volume/Watts at Various Blower Speeds External Medium- Medium- Medium- Medium- Static High Low Static High LOW Pressure High Low Pressure High Low in•w.9. cfm Watts cfm Watts cfm Watts cfm Watts in.W.9. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1130 453 900 328 750 261 680 237 0.00 1660 696 1370 604 1095 495 935 386 0.10 1115 432 885 321 735 255 670 230 0.10 1620 658 1365 568 1115 468 945 374 020 1100 _413 870 imioi720 249 655' 223 " 020 1580 621 1355 535 1135 442 960 362 0.30 1070 396 855 304 700 241 640 217 0.U.4©0 ���� 562 1300 478 :.1100 403 945 335 ;.. 595 1335 513 1130 423 955 350 0.40 1030 375 830 294 685' 234 620 209 0.50 990 356 800 283 655 223 590 200 0.50 � � ��� 1270 420 .''1035 358 880 301 450 1080 382 925 320 0.60 930 , 335 750 261 • 0 207 s 535 ' 186 0.70 870 315 705 245 540 193 490 1750.70 1245 458 1125 393 975 333 835 282 158 0 80 1160 434 1045 364 : 915 310 775 262 0,80 785 285' 615 223 455 175 405 0.90 615 247 485 196 375 157 345 143 0.90 1045 393 940 334 830 283 785 268 ML180UH045P36A PERFORMANCE(Less Filter) ML180UH090P36B PERFORMANCE(Less Filter) Air Volume I Watts at Various Blower Speeds External Air Volume I Watts at Various Blower Speeds External Static Medium- Medium- Low Static Medium- Medium- Low High High Low High High Low Pressure Pressure in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0 00 1795 781 1450 606` 1195 464 970 390 0.00 1670 711 1335 614 1140 485 925 388 ; 0.10 1620 663 1335 577 1130 470 940 37666 �'�� 1760 ��� ���� 547" 11?0 440 975 368 0205 452 970 378 1570 619 1330 543 1115 455; 950 3 0.30 1525 598 1315 511 1140 432 950 349 0.30 1685 656 1410 525 1170 420 980 356 040 1470 552 1275 491 1125 413 945 336 040 1630 625 1370 501 1150 400 955 340 0.50 1400 525 1235 455 1085 384 925 317 0.50 1535 569 1315 469 1125 391 925 326 0.60 1330 486 1185 422 1050 361 885 300 0.60 1470 533 1275 440 1085 367 910 309 0.70 1225 450 1135 395 995 336 840 283 00.8© 1365 490 ��85 407105 380 835 344 314 785 266 840 290 0,80 . 1135 418 1010' 359 925 315 785 '' 258 ' 0.90 1160 430 1000 352 815 285 680 258 0.90 1020 388 930 329 820 278 650 227 ML180UH070P24A PERFORMANCE(Less Filter) ML180UH090P48B PERFORMANCE(Less Filter) Air Volume/Watts at Various Blower Speeds External Air Volume I Watts at Various Blower Speeds External Medium- Medium- pew Static High Medium Low Static High Watts High Low Pressure Pressure in w g cfm Watts cfm Watts cfm in.w.9. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1160 , 450 1005 380 865 309 `' 0.00 2160 873 1825 775 1515 649 1260 544 0.10 1135 439 990 369 845 299 0.10 ,2030 804 1780 719 1525 613 1280 518 0.20' 1115 429 975 358 820 289 0.20 1910 740 1740 666 1535 MI 1305 493 0.30 1085 410 955 348 790 279 0.30 1840 698 1705 643 1500 551 1305 474 040 1045 389 925 335 775 270 0.40 1770 664 1635 594 1460 517 1280 445 0.50 1015 374 885 321 735 260 0.50 1665 625 1560 567 1410 483 1225 420 0.60 965 358 835 307 700 248 0.60 1585 595 1470 523 1330 451 1190 391 0.70 890 335 780 289 635 232 0.70 1470 561 1365 483 1260 421 1115 368 0.80 810 315 700 268 560 214 0,80 1355 514 1230 433 1155 392 1020 338 0.90 715 289 565 238 420 189 0.90 1200 471 1120 399 1020 345 920 315 ML180UH 1 Page 14 BLOWER DATA MLI80UH110P48C PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium- Medium- Low Pressure High Low in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2170 980 1845 792 1565 678 1270 564 0.10 2125 919 1820 747 1555 648 1300 540 0.20 2080 862 1790 705 / 1540 619 1335 516 0.30 2015 807 1745 652 1545 587 1335 498 0.40 1940 748 1695 629 1505 552 1320 470 0.50 1850 716 1635 581 1470 523 1295 449 0.60 1775 679 1575 560 1395 484 1235 417 0.70 1680 637 1470 508 1320 450 1170 387 0.80 1560 592 1350 469 1205 404 1050 345 0.90 1425 546 1190 424 1060 362 910 307 MLI80UH110P60C PERFORMANCE(Less Filter) Air Volume/Watts at Different Blower Speeds External Bottom Return Air,Side Return Air with Optional Return Single Side Return Air-Air volumes in bold require field Static Air Base, Return Air from Both Sides or Return Air from fabricated transition to accommodate 20 x 25 x 1 in.air filter Pressure Bottom and One Side. in order to maintain proper air velocity. in.w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2575 1391 2270 1050 1845 860 1430 661 2715 1509 2175 1103 1695 858 1410 653 0.10 2520 1359 2250 1034 1860 841 1455 654 2605 1454 2160 1060 1740 848 1430 651 0.20 2465 1329 2230 1018 1870 823 1480 647 2505 1401 2150 1018 1785 838 1450 649 0.30 2385 1307 2180 981 1885 809 1540 646 2435 1349 2115 991 1795 818 1485 638 0.40 2295 1256 2105 942 1865 778 1570 638 2350 1308 2070 965 1805 801 1480 631 0.50 2200 1214 2055 909 1845 762 1570 619 2260 1274 2010 929 1785 775 1480 621 0.60 2130 1186 1985 882 1795 741 1550 604 2175 1228 1955 901 1755 752 1490 611 0.70 2015 1150 1890 848 1720 711 1505 580 2085 1186 1850 853 1710 722 1460 594 0.80 1905 1105 1810 815 1675 687 1470 565 1965 1147 1785 818 1640 689 1425 567 0.90 1795 1054 1710 779 1545 647 1375 533 1830 1094 1700 794 1555 662 1355 545 MLI80UH135P60D PERFORMANCE(Less Filter) Air Volume/Watts at Different Blower Speeds External Bottom Return Air,Side Return Air with Optional Return Single Side Return Air-Air volumes in bold require field Static Air Base,Return Air from Both Sides or Return Air from fabricated transition to accommodate 20 x 25 x 1 in.air filter Pressure Bottom and One Side. in order to maintain proper air velocity. in.w.g. Hi•h Medium-Hi•h Medium-Low Low Hi•h Medium-Hi•h Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2785 1492 2205 1083 1665 840 1345 632 2810 1528 2185 1100 1705 835 1260 622 0.10 2750 1441 2220 1056 1725 825 1395 625 2725 1463 2180 1075 1715 827 1320 624 0.20; 2720 1392 2235 1029 1785 810 1445 618 2640 1400 2180 1051 1720 819 1380 626 0.30 2605 1362 2220 1002 1820 800 1460 623 2575 1374 2165 1005 1790 803 1420 622 0.40 2495 1312 2185 968 1845 779 1485 616 2495 1343 2145 988 1775 791 1450 617 0.50 2420 1275 2135 939 1825 767 1505 605 2405 1292 2105 948 1780 777 1470 610 0.60 2335 1234 2080 909 1825 753 1495 593 2305 1257 2045 914 1775 753 1480 593 0.70 2220 1190 1995 864 1760 716 1475 576 2215 1214 1970 884 1740 727 1455 583 0.80 2120 1157 1890 835 1680 686 1435 558 2110 1170 1890 851 1675 699 1430 565 0.90 1985 1102 1790 794 1605 656 1390 536 1985 1122 1790 811 1600 667 1380 543 ML180UH/Page 15 REVISIONS Sections Description of Change Gas Heat Accessories Updated Natural Gas to LPG/Propane Kit catalog numbers for all inputs. otslGN A....1 CE RTIFI E DT. W4I4 www.ahridirectory.org CER71FtEO Visit us at www.iennox.com !! 1VJV1JI ' For the latest technical information,www.LennoxPROs.com Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries,Inc. OFFI R„ , C PY 4AC13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM AIR CONDITIONER FORM NO.4AC13-100(10/2017) • R410a Refrigerant • High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity • Top discharge directs hot air away from living area and shrubbery • All units factory run tested • Available with louvered panel or wire guard coil protection • Easy access to electrical panels • Corner mounted service valves for easy hook-up and service • Liquid line filter drier shipped loose • Charged for 15 feet of interconnecting tubing • All units ETL and ETLC approved and AHRI certified WARRANTY 10 year limited warranty on compressor,10 year limited warranty on all parts,extended warranty available' 'Warranty provides for a total of 10 years of limited warranty coverage(Standard 5-year limited parts warranty plus an additional 5year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 70 year coverage.Unregistered equipment defaults to 5-year coverage. Lifetime limited heat exchanger warranty applies to registered equipment only (Standard 20 years with no online registration).See full warranty at www.alliedair. r. } com for terms,conditions and exclusions. I M, ow'rFR LIMITED PARTS Am 10-YEAR �t4► 1RFffDe: WARRANTY CUS I Page 1 f r SPLIIT SYSTEM AIR CONDIRD I MODEL NUMBER GUIDE 4AC13B/L24P - 7,8A R410 A I TT li-MINOR REVISION CODE AC=CONDENSER MAJOR REVISION CODE 13-13 SEER NOMINAL VOLTAGE P-208-230V/60HZ FAMILY/COIL PROTECTION SINGLE PHASE B=WIRE GUARD NOMINAL CAPACITY L=LOUVERED 24-24,000 BTUH ELECTRICAL AND PHYSICAL DATA Compressor Fan Motor Weight(lbs.) Voltage/ Min. Max Fuse R�9e Voltage �arcuit , Model' 14z. " Range; . (Amps)* ' Rated Locked Full Load Rated Nnm ,(oz Yr :�m Phase' (Amps) ' Load Rotor ' (Amps) ' . HP RPM" ' (Amps)f (Amps) 4AC13`18P 208-230/60/1 197-253 10.9 15 8.1 39 0.7 1/10 1010 62 125 136 4AC13`24P 208-230/60/1 197-253 141 20 10.7 ' 53 0.7 1/10 1010 63 126 137 4AC13`30P 208-230/60/1 197-253 15.6 25 11.6 59 1.1 1/5 1090 82 139 147 4AC13"36P 208-230/60/1 197-253 20.1 35 15.2 70 1.1 1/5 1090 84 141 149 4AC13`42P 208-230/60/1 197-253 28.1 45 21.1 90 1.7 1/4 825 104 184 194 4AC13`48P , 208-230/60/1 197-253 31.9 50 24.1 100 1.7 1/4 825 124 181 192 4AC13`60P 208-230/60/1 197-253 29.4 60 22.1 120 1.7 1/4 830 144 194 205 =B or L B=Wire.Guard L=Louvered t Overcurrent protection device ++ Factory charge adequate for 15 feet of line set.Adjust per Installation Instructions. UNIT DIMENSIONS&SOUND RATINGS Note:Dimensions listed are unit sizes w/o packaging P Ohne rasions 4ouf+d .. . B Ratui93 ' `\\������I�� %ce ."- A-width ' B-depth C height EdBa) '��� may'; On) (in.) Ort.) �>� > Yil 4AC13'18P 24.25 24.25 25 74 11111111 III ii{III{�/// // t II 1iIIIA VIII ,I 11, IIIIIIllllq� ---- hI�IIIIIpllllglll 4AC73`24P. 24.25 24.25 25 74 i,Ilillllliiq ,_.III Illillillllll 4AC13*30P 24.25 24.25 29 74 1i 11111;11111 IIIIIIIIIIlIIIIIIIII'��� 4AC73`36P 24.25 24.25 29 74 I " 1111 IIIIIIIIIIIIIII IIII II'.1.1.1.i..11111111111 ; 'Illllglllllllll IIIJ1 4AC13*42P 11 28.25 28.25 29 79 VIII { II u,,,�iilllqI i DIIlillllllllll 4AC13*48P 28.25 28.25 33 79 111 ",iI I�I IIII, III II i 11111111"i'gl 1111 I!' IIgIIII!; IIIIIIIIIIIIIDII �i 4AC13*60P 28.25 28.25 29 80 i c'�1 c�;.'!i mss, =8 or L B=Wire Guard L=Louvered Page 2 • SPLIT SYSTEN1 AIR C I ITI NER 4 COOLING PERFORMANCE WITH EVAPORATOR COILS tNodit Refrdgeran r ReMgerant- fndpor Metering' oisngctio i size , DevrCg .. c Rates! Rated SEER 'EER AHRI Sensible CFM .Outdoor Indoor .'Evaporaaf Co8.3 . .. Capacity Capacity o "? Air Handier , 8rs pistAri TXSI E(C,H,M,U)1P23(A,B)+TOR 13.00 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/86 3/8 or 1/4' 0.053 A4TXV01 op rIn E(C,M,U)1P24(A,B)+TDR 13.00 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8' 3/8 or 1/4' 0.053 A4TXV01 E(C,H,M,U)1P29A+TDR 13.00 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8' 3/8 or 1/4' 0.053 A4TXV01 E(C,H,M,U)1P23(A,B)+TDR 13.00 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/85 3/8 or 1/4' 0.057 A4TXV01 , E(C,M,U)1P24(A,B)+TDR 13.00 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/85 3/8 or 1/4' 0.057 A4TXV01 sry ▪ E(C,H,M,U)1P29A+TDR 13.00 11.00 22800 16800 800 5/8 f 3/8 3/4 3/8 `8/85 3/8 or 1/4' 0.057 A4TXVO1 ▪ E(C,M,U)1P30(A,B)+TDR 13.00< 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/86 3/8 or 1/4' 0.057 A4TXV01 E(C,H,M,U)1P36(A,B,C)+TOR 13.00 11.00 22800 16800 800 5/8 3/8 3/4 3/8 :5/8' 3/8 or 1/4': 0.057 A4TXV01 E(C,H,M,U)1P23(A,B)+TDR 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 a E(C,M,U)1P24(A,B)+TDR 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 0 E(C,H,M,U)1P29A+TDR 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 U E(C,M,U)1P30(A,B)+TDR 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P36(A,B,C)+TDR 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 , E(C,H,M,U)1P36(8,C)+TDR 13.00 11.00 34000 25000 1200 3/4 3/8 7/8 3/8 3/46 3/8 0.072' A4TXV01 E(C,H,M,U)1p43(S,C)+TDR 13.00 11,00 34000 25000 1200 3/4 3/8 7/8 3/8 3/46 3/8 0.072 A4TXV01 E(C,H,M,U)1p500+70R 13.00 11.00 34000 25000 1200 3/4 3/8 7/8 3/8 3/46 3/8 0.072 A4TXV01 E(C,H,M,U)1P43C+TDR 13.00 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/46 3/8 0.075 A4TXV01 v E(C,H,U)1P49C+TDR 13.00 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/46 3/8 0075 A4TXV01 E(C,H,M,U)1P50C+TDR 13.00 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/46 3/8 0.075 A4TXV01 E(C,H,U)1p490+TDR 13,00 11.00 47000 34300 1600 7/8 3/8 7/8 318 7/8 3/8 0.082 A4TXV02 4 E(C.H UyIP62C+TOR- 13.00 11.00 47000 34300 1600 7/8 3/8 7/8 3/8 77/8 3/8 0.082 A4TXV02 E(C,H,U)1p620+'{DR 1300 11.00 47000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 a E(C,H,U)1P49C+TDR 13.00 11.00 57000 41000 1800 7/8 3/8 7/8 3/8 7/8' 3/8 0.090 A4TXV02 0 40 E(C,H,U)1P62C+TDR 13.00 11.00 57000 41000 1800 7/8 3/8 7/8 3/8 7/8' 3/8 0.090 A4TXV02 Q E(C,H,U)1P620+TDR 13.00 11.00 57000 41000 1800 7/8 3/8 7/8 3/8 7/8' 3/8 0.090 A4TXV02 7 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 270/240. 2 Required to achieve AHRI rating. • =B or L B=Wire Guard L=Louvered Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 270/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" 6 For lines 25 ft or over,use 7/8" 7 For lines 25 ft or over,use 7-7/8" Page 3 Y SPLIT SYSTEN 1 AIR CONDITIONER COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES indoor Refrigerant Refrigerant Expansion, Connection Line Size Device Rated Rated variable MI 1„-, Sensible , CFM Outdoor Indoor o Evaporator Speed SF.,ER Capacity Capacity ° Coil Furnace CtIH STUN c or, o 4 a 0 „ Air- HanC3ler Y a x v l r? ;i BCS3M18C`***P 13.0 11.0 17,600 13,380 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° BCE3M18C****P BCS3M24C*`**P 13.0 11.0 17,600 13,380 650 3/4 3/8 3/4 3/8 5/85 3/8 or l/4° BCE3M24C****P BCS2M24V**``P 14.0 12.0 17,600 13,380 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° BC53M24E***`P 14.0 11.0 17,600 13,380 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,H,M,U)1P23A 80G1DF045AE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P23A 80G1UH045AE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 333///888 /S ort/4° E(C,H,M,U)1P23A 80G2UH070AV12 14.0 12.0 17,600 13,380 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,H,M,U)1P23B 80G1DF070BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,H,M,U)1P23B 80G1UH070BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,H,M,U)1P23B 95G1DF045BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P23B 95G1UH045BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 ort/4° E(C,H,M,U)1P23B 95G1UH070BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P23B 95G2DF045BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° 0. E(C,H,M,U)1P238 95G2DF070BV16 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° o E(C,H,M,U)1P23B 95G2UH0456V12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/$i 3/8 or 1/4° r,2 X r U E(C,H,M,U)1P23B 95G2UH0706V12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° 0 Q E(C,H,M,U)1P29A 80G1DF045AE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,H,M,U)1P29A 80G1UH045AE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P29A 80G2UH070AV12 14.0 12.0 17,600 13,380 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,H,M,U)1P29B 80G1DF0708E12 14.0 .12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,H,M,U)1P29B 80G1UH070BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P29B 95G1DF045BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/44 E(C,H,M,U)1P298 95G1UH045BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P29B 95G1UH070BE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,H,M,U)1P29B 95G2DF045BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/a 3/E 5/8r 3/8 or 1/a° E(C,H,M,U)1P298 95G2DF070BV16 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/44 E(C,H,M,U)1P29B 95G2UH045BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8� 3/8 or 1/4° E(C,H,M,U)1P29B 95G2UH070BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P19A 80G1DF045AE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or t/4° E(C,M,U)1P19A 80G1UH045AE12 14.0 1111:55_ 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8r 3/8 or 1/4° E(C,M,U)1P19A 80G2UH070AV12 13.5 17,600 13,380 650 3/4 3/8 3/4 3/8 5/85 3/Sort/4° =B or L B=Wire Guard L=Louvered Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all A/lied Air Enterprises furnace and AH products. 4 For lInes 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 4 SPLIT SYSTEM AIR CONDITIONER 4AC :' COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES Model° Refrigerant Refrgerantndapr,` Connection Line Size x13aEt51on baYtce Vartablef, Rated :Rated e Evaporator Speed,', SEER AR( i Co�1 Furnace, ' Capacity Cayacjty CFM Outdoor ' Tndoor' p or -' 8fik1M 67Yt1H «� Air Handier . ' t 1, E(C,M,U)1P19B 8OG1DFO7OBE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P19B 80G1UH070BE12 14.0 11.5 78,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/44 E(C,M,U)1P19B 95G1DF045BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/44 E(C,M,U)1P19B 95G1UH045BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P198 95G1UH0700E12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,M,U)1P19B 95G2DF0458V12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P196 95G2DFO7OBV16 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,M,U)1P19B 95G2UH045BV12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4° E(C,M,U)1P19B 95G2UH070BV12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° CO E(C,M,U)1P24A 80G1DF045AE12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P24A 80G1UH045AE12 14.0 11.5 18,000 13,680 6503/4 3/8 3/4 3/8 5/85 3/8 or 1/44 rn rn Q E(C,M,U)1P24A 80G2UH070AV12 13.5 11.5 17,600 13,380 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° o E(C,M,U)1P24B 80G1DF070BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4' E(C,M,U)1P24B 80G1UH070BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/44 E(C,M,U)1P24B 95G1DF045BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P24B 95G1UH045BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 7/44 E(C,M,U)1P24B 95G1UH070BE12 14.0 11.5 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/44 E(C,M,U)1P24B 95G2DF045BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/4° E(C,M,U)1P24B 95G2DF0700V16 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/4. E(C,M,U)1P24B 95G2UH045BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/4° E(C,M,U)1P246 95G2UH070BV12 14.0 12.0 18,000 13,680 650 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4' €3C53M24C****P CE3M24G"'*'P 73;0 11.0 22,800` 17,330 800: 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 BCS2M24V****P 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4* 8CS3M30E****P 14.0 11.0 22,800 1;330 800 3/4 3/8 ,3/4 3/8 5/86 - 3/8 or 1/44 i1. NE(C H M,U)1P23A 80G1DF045AE12' 14.0 12.0 23,000 17,480 800' 3/4 3/8 3/4 ' 3/8 55/85 3/8©r 1/4k E(C,H,M,U)1P23A 80G1UH045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 8/8s 3/8 or 1/44 E(C,H,M,U)1P23A 80G2UH070AV12 14.0 12.0 22,800 17330 800 3/4 3/8 3/4 3/8 5/86 3/8 Or 1/44 4 E(C,H,M,U)11,236 80G1DF07013E12 133 = 11.5 23,000 17,480 800 ' 3/43/8 3/4 3/ 8 Si 3/8 or 1/44 E(C,H,M,U)1P238 80G1UH0708E12 13.5 tl.5 .! 23,000 17,480' 800 3/4 3/8 3/4 3/8 5/$5 3/8 or 1/44 E(C,H,M,U)1P238 9SG1DF0458E12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,P1,U)1P238 95G1UH0458E12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/86 3/8 or 1/44 =B or L B=Wire Guard L=Louvered Note.' 7 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on al/Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 5 PI IT SY',`,Trztvl AIRCONDiTIONER COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES ,'t Indoor Model . Re{r 4rant 1 8{ri9size J4 sa03100 M_ , ' ottorr lute size pevice'' a Rated Rated ` o Yarlable ARl Sensible Outdoor indoor Spud SEER EER - --AR* l' CapacltY c Evapoitm - 0 • • w B ), Furnace' 97UH BTUH F c*S �'s pr o c'' tx a Air Handler ur o it yr t- vi' E(C,H,M,U)1P238 95G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/4' E(C,H,M,U)1P23B 95G2DF045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P23B 95G2DF07OBV16 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/44 E(C,H,M,U)1P23B 95G2UH045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4' E(C,H,M,U)1P23B 95G2UH070BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P29A 80G1DF045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,H,M,U)1P29A 80G1UH045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4' E(C,H,M,U)1P29A 80G2UH070AV12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P29B 80G1DF070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P29B 80G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P29B 95G1DF045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P29B 95G1UH045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P29B 95G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 a E(C,H,M,U)1P29B 95G2DF045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 o N E(C,H,M,U)1P29B 95G2DF070BV16 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° N 1.* o F M a V E(C,H,M,U)1P29B 95G2UH045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° 1. E(C,H,M,U)1P29B 95G2UH070BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P36A 80G1DF045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P36A 80G1UH045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P36A 80G2UH070AV12 14.0 12.0 22,800 17.330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P36B 80G1DF070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/44 E(C,H,M,U)1P36B 80G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8' 3/8 or l/44 E(C,H,M,U)1P368 95G1DF045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/44 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/44 E(C,H,M,U)1P36B 95G1UH045BE12 E(C,H,M,U)1P36B 95G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 E(C,H,M,U)1P36B 95G2DF045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 ' E(C,H,M,U)1P36B 95G2DF070BV16 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,H,M,U)1P36B 95G2UH045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/4' E(C,H,M,U)1P36B 95G2UH070BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8' 3/8 or 1/44 E(C,H,M,U)1P36C 95G2DF090CV20 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/44 =B or L B=Wire Guard L=Louvered Note: 21 CertifiedRequired to in accordance with Unitary Air Conditioner Certification Program,which is then basedTXV onis AHRIrequirStandared. d 270/240 and achieve AHRI rating. If NA(Not Applicable)is in the piston column, 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 6 SPLIT SYSTEM V CONDITIONEF 4, CIS COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES indoort Model Refrrg8rant Refrigerant, JPanal Connection Line Size Ebevici#rtl l7eve Variable '' Rated Ratted ARI Sensible aevaporator Speed SEER F.tzft >~apael;Y+ capacity `"CFM' Outdoor Indoor Coil Furnace Alt Handler, c 3 �s uY E(C,H,M,U)1P36C 95G2DF110CV20 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,H,M,U)1P36C 95G2UH090CV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4' E(C,M,U)1P19A 80G1DF045AE12 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4' E(C,M,U)1P19A 80G1UH045AE12 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P19A 80G2UH070AV12 14.0 11.5 22,600 17,180 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P198 80G1DF0708E12 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P19B 80G1UH070BE12 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P198 95G1DF045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P19B 95G1UH045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P19B 95G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4" E(C,M,U)1P19B 95G2DF045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P19B 95G2DF070BV16 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P19B 95G2UH045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" Q. E(C,M,U)1P19B 95G2UH070BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24A 80G1DF045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4' r` > M � x E(C,M,U)1P24A 80G1UH045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" o E(C,M,U)1P24A 80G2UH070AV12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P248 80G1DF070BE12 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24B 80G1UH070BE12 13.5 11.5 23,000 17,480 800 3/4 3/8 3/4 3/8 5/8s 3/8 or 1/4" E(C,M,U)1P24B 95G1DF045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24B 95G1UH045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24B 95G1UH0706E12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24B 95G2DF045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24B 95G2DF070BV16 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P24B 95G2UH045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4' E(C,M,U)1P24B 95G2UH070BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P30A 80G1DF045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P30A 80G1UH045AE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P30A 80G2UH070AV12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" E(C,M,U)1P3OB 80G1DF070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4" =B or L B=Wire Guard L=Louvered Note: 7 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 270/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 7 COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES Indoor Indoor Model Refrigerant Refrigerant Expansion Connection Line Size Device BRated Rated Variable ARISensible Outdoor Indoor Evaporator Speed x CFM SEER EER Capacity Capacity Coil Furnace BTUH STUN o v He > Q or a v c Y°„ w Air Handler a 4 _ : a 4 E(C,M,U)1P30B 80G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P3OB 95G1DF045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° 0. E(C,M,U)1P3OB 95G1UH045BE12 14.0 12.0 22,800 17,330 800 3/4 3/8 3/4 3/8 S/85 3/8 or 1/4° E(C,M,U)1P30B 95G1UH070BE12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 S/85 3/8 or 1/4° N M o >< E(C,M,U)1P30B 95G2DF045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° o d a E(C,M,U)1P3OB 95G2DFO7OBV16 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P3OB 95G2UH045BV12 14.0 12.0 23,000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° E(C,M,U)1P3OB 95G2UH070BV12 14.0 12.0 23.000 17,480 800 3/4 3/8 3/4 3/8 5/85 3/8 or 1/4° BCS3M30C****P 13.0 11.0 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 BCE3M30C****P BCS2M36V****P 14.0 12.0 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 BC53M30E****P - 14.0 11.0 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23A 80G1DF045AE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23A 80G1UH045AE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23A 80G2UH070AV12 13.5 11.5 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 80G1DF070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 8061DF090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 80G1UH070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 0 E(C,H,M,U)1P23B 80G1040908E16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 M M 5 tot E(C,H,M,U)1P23B '95G1DF045BE12 13,5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 a r .- 0 QE(C,H,M,U)1P23B 95G1DF0708E16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P2313 95G1UH0459E12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 95GIUH070BE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 95G2DF045BV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B . 95G2DF070BV16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 95G2UH045BV12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P23B 95G2UH0708V12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29A 80G1DF045AE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29A 80G1UHO4SAE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29A 80G2UH070AV12 13.5 11.5 28,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 80G1DF070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 =B or L B=Wire Guard L=Louvered Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 270/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 8 SPLIT SYSTEIRI AIR CONDITIONER 4AC13 COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES tndatr- htotlel Refr j4rarrt Refrisprant trrdoo r . to 11/10.Size EXParitsiar1 'Devce ;? „ Varrabte = 'sated '.Rated' Evaporator , Spud SEER EER ARI 1 Senslbfe - t3uttlgpr.; ndaor .`. C t Fumace 08pacttY BTUI4y Fht t p .pr t 1„„ r 7`lfH EA sc ,` r+ Air Hatutter J ° , -1 E(C,H,M,U)1P29B 80G1DF090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 80G1UH070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 80G1UH090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G1DF045BE12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G1DF070BE16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G1UH045BE12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G1UH070BE12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G2DF045BV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G2DF070BV16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)12298 95G2UH045BV12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P29B 95G2UH070BV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36A 80G1DF045AE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36A 80G1UH045AE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 a E(C,H,M,U)1P36A 80G2UH070AV12 13.5 11.5 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 0 M E(C,H,M,U)1P36B 80G1DF070BE12 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 M E(C,H,M,U)1P36B 80G1DF090BE16 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 o E(C,H,M,U)1P36B 80G1UH070BE12 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 80G1UH090BE16 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 95G1DF045BE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 95G1DF070BE16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 95G1UH045BE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P368 95G1UH070BE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 95G2DF045BV12 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 95G2DF070BV16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36B 95G2UH0458V12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P366 95G2UHO7OBV12 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36C 95G1DF090CE16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36C 95G1UH090CE16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36C 95G2DF090CV20 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P36C 95G2DF110CV20 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 =B or L B=Wire Guard L=Louvered Note: T Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 270/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 9 13 SPLIT SYSTEM AIR CONDITIONEr< ;A . COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES �dilbr Refrigerant Refrigerant todow ..' Expansion, Connection Line SizeMG‘del Devicem Rated Raced X Variable AES , ,SeSslbie ,CFM outdoor Indoor Cvaporator _Speed SEER EER Capa a capad Coil ' 'Furnace BMW_< BTU“ ii„ is „ 4 ' or 3 't3 . .3 to 3 tl O Air 1,Candler E(C,H,M,U)1P36C 95G2UH090CV12 14.0 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 80G1DF070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 80G1DF090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 80G1UH070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 80G1UH090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G1DF045BE12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G1DF070BE16 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G1UH045BE12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G1UH070BE12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G2DF045BV12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G2DF0708V16 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43B 95G2UH045BV12 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P438 9SG2UHO7OBV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 a E(C,H,M,U)1P43C 95G1DF090CE16 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 0 E(C,H,M,U)1P43C 95G1UH090CE16 13.5 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 o a (� E(C,H,M,U)1P43C 95G2DF090CV20 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43C 95G2DF110CV20 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,H,M,U)1P43C 95G2UH090CV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P30A 80G1DF045AE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P30A 80G1UH045AE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P30A 80G2UH070AV12 13.5 11.5 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 80G1DF070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 80G1DF090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 80G1UH070BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 80G1UH090BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P30B 95G1DF045BE12 13.5 11.5 29.000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 95G1DF070BE16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 95G1UH045BE12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P3OB 95G1UH070BE12 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P308 95G2DF045BV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 =B or L B=Wire Guard L=Louvered Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 10 SPLIT SYSTEM AIR CONDITIONER COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES iIndoor _ - ndoo Refrigerant RefrigerantIndoor Mode Expansion Connection Line Size E Variable Rated Rated Device o Evaporator Speed SEER EER ARI i Sensible B Coil Furnace Capacity Capacity CFM Outdoor Indoor b' or a BTUH BTUH o ;9 "c Air Handler 4 2 g. 0 Pt d' 'g'. cr '' ri.cocr J 47 .4 - E(C,M,U)1P3OB 95G2DF0703V16 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P309 95G2UH045BV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 0 E(C,M,U)1P308 95G2UH0709V12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 M E(C,M,U)1P30C 95G1DFO9OCE16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 M o M i X Q E(C,M,U)1P30C 95G1UH090CE16 13.5 11.5 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 O Q 't E(C,M,U)1P30C 95G2DF090CV20 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P30C 95G2DF110CV20 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 E(C,M,U)1P30C 95G2UH090CV12 14.0 12.0 29,000 21,750 1000 3/4 3/8 3/4 3/8 3/4 3/8 BC53M36C****P BCE3M36C****p 13.00 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/48 3/8 BCS2M36V**"*p 13.50 11.00 34.000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 BCS3M36E****P 14.0 11.0 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36B EFVI2BC 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36B 80G10F0909E16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36C 80G1DF110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36B 80G1UH090BE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,11,U)11,36C 80G1UH090CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36C 80G1UH110CE20 13,50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 a E(C,H,M,U)1P36C 80G2UHl10CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 to M E(C,H,M,U)1P36C 95G10F090CE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 43 r E(C,H,M,U)1p36C 95G1DF11QCE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 a i- 4 d' E(C,H,M,U)1P36C 95G2DF090CV20 13,50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 4 E(C,H,M,U)1P36C 95G2DF110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,MU)11)36C 95G1UH090CE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/4' 3/8 E(C,H,M,U)1P36C 95G1UH110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36C 95G2UH090CV12 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P36C 95G2UH090CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/4' 3/8 E(C,H,M,U)1P36C 95G2UH110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P438 EFV12BC 13,50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P438 80G1DF090BE76 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/$ E(C,H,M,U)1P43C 80G1DF110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P438 80G1UH090BE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 =B or L B=Wire Guard L=Louvered Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over use 3/8" 5 For lines 25 ft or over use 3/4" Page ii SRI IT SYSTEM AR CONDITION:ER 4AC13 COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES Refrigerant Refrigerant Indoor Expansion Indoor Co tt*t ion'' Line Size Device Model Rated Rated Variable : ARI Sensible cFm , Outdoor lndoar Evaporator Speed SEER EER capacity Capacity g 3 Furnace #'tUH 15TUH c G w r Air Handleruoi .2 sr E(C,H,M,U)1P43C 80G1UH090CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 80G1UH110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 80G2UH110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G1DF090CE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/4° 3/8 E(C,H,M,U)1P43C 95G1DF110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G2DF090CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G2DF110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G1UH090CE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G1UH11OCE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G2UH090CV12 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P43C 95G2UH090CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 0. E(C,H,M,U)1P43C 95G2UH110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 1.0 E(C,H,M,U)1P5OC EFV16CC 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 o X V E(C,H,M,U)1P50C 80G1DF110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 O. Q E(C,H,M,U)1P5OC 80G1UH090CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 80G1UH110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 80G2UH110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G1DF090CE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/4° 3/8 E(C,H,M,U)1P50C 95G1DF110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G2DF090CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G2DF110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G1UH090CE16 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G1UH110CE20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G2UH090CV12 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G2UH090CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 E(C,H,M,U)1P50C 95G2UH110CV20 13.50 11.00 34,000 24800 1200 3/4 3/8 7/8 3/8 3/46 3/8 BCS3M42C`"""P 13,0 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 CI- BCE3M42C****P M BCS2M42V*"**P 13.5 11.5 40,000 29,200 1400 7/8 3/8 718 3/8 3146 3/8 r 4.1 BCS3M42E****P 14.0 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 =B or L B=Wire Guard L=Louvered Note. 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 12 L;1 SYSTEM ;SIR CONDITIONER 4,(13 COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES lrtipor . , . Refrigerant ttefrlgerant Ct nnection ExAanslon Y Lin `Seze YariaWe . dated, Ram _ TSerticb,''' , �s`, E`a r�ttu �ARI '-5ensrbfe o Spend, ,.,SE-6:14' SEER EER 2 C41t Furnace C7C38Cf ! CapactF: CFM ts�tdoor Indoor or BTU . BTUFI . c e 'Air l4andier t„ --5 ''''Zi � � � yr .0 � ..i u'f BCS2M48V'""P 13.5 11.5 40,000 29,200 14007/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43B 80G1DF090BE16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43B 80G1UH0906E16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43B 95G1DF070BE16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 8OG1DF110CE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 8OG1UH090CE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 80G1UH11OCE2O 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95G1DF090CE16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95G1DF110CE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95G1UH090CE16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95GIUH11OCE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95G2DF090CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95G2DF110CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,M,U)1P43C 95G2UH090CV20 13.5 ns 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 0. CNI et E(C,H,M,U)1P43C 95G2UH110CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 2 E(C,H,U)1P49C 80G1DF110CE20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 o x U d Tr E(C,H,U)1P49C 80G1UH090CE20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 Q E(C,H,U)1P49C 80G1UH710CE20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 80G2UH11OCV20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G1DF090CE16 13.5 11:0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G1DF110CE20 13.5 11.040,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G1UH09OCE16 13.5 11.5 40.000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G1UH110CE20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G2DF090CV20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G2DF110CV20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G2UH090CV20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,H,U)1P49C 95G2UH110CV20 13.5 11.0 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,M,U)1P50C 8OG1DF11OCE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,M,U)1P50C 80G1UH090CE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/as 3/8 E(C,M,U)1P50C 80G1UH11QCE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 E(C,M,U)IPSOC 80G2UH110CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/40 3/8 =B or L 8=Wire Guard L=Louvered Note. 1 Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. /f NA(Not Applicable)is in the piston column,then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 13 SPLIT ' 5 M AIS CONDITIONER COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES Indoor " Refrigerant irxparision Refrt9erar+t ' Siz Model Connection Line Size Device ' Rated',, Rated Vanabig X,RI , sible Outdoor Indoor Evaporator '`Speed ' S� EER; Capacity' Capacity CFM'• i 13 0 y Coil, cufnat 870H 810F1 - a Air ridier, a E(C,M,U)1P50C 95G1DFO90CE16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 E(C,M,U)1P5OC 95G1DF110CE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 0, E(C,M,U)1P50C 95G1UH090CE16 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 N No * E(C,M,U)1P50C 95G1UH110CE20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 p F M a c U E(C,M,U)1P50C 95G2DF090CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 Q E(C,M,U)1P5OC 95G2DF110CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/46 3/8 E(C,M,U)1P5OC 95G2UH090CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/4' 3/8 E(C,M,U)1P50C 95G2UH110CV20 13.5 11.5 40,000 29,200 1400 7/8 3/8 7/8 3/8 3/4' 3/8 BCS3M4EC****P 13.00 11.00 47,000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 A. BCE3M48C****P 00 0 'et N s . 13.50 11.00 47,000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 o 1,__< r BC52M48V**•P o a t,j Q 1. BCS3M48E'***P 14,0 11.0 47,000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 BC53M60C****P 13.00 11.00 57,000 41000 1800 7/8 3/8 7/8 3/8 7/8' 3/8 0. BCE3M6OC****P 0N IO o 0 X M BCS2M60V****P 13.50 11.00 57,000 41000 1800 7/8 3/8 7/8 3/8 7/8' 3/8 o Q 5 4 4. BC53M60E****P 13.5 11.0 57,000 41000 1800 7/8 3/8 7/8 3/8 7/8' 3/8 =B or L B=Wire Guard L=Louvered Note. I Certified in accordance with Unitary Air Conditioner Certification Program,which is based on AHRI Standard 270/240 2 Required to achieve AHRI rating. If NA(Not Applicable)is in the piston column,then 7XV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. 4 For lines 25 ft or over,use 3/8" 5 For lines 25 ft or over,use 3/4" Page 14 SPLITS'y'STEM AlFZ CONDITIONER 3 TONER AI3 COOLING PERFORMANCE- EXTENDED RATINGS trrdoor Outdoor Tamp-O8 E Model, 1ttCtoor 95.... Outdoor Temp -65. 82 105 MOd81 Pist64tor U$/WB Piet# ,`F ` tnstatled 5tvh '� S/T kW ,. Stull '6/T �� �� "tXY SIT' kW Btuh S/T„ 'kW 8tuh . SIT kW Btuh 85/72 19,900 0.67 1.49 19,000 0.71 1.61 18,500 0.74 1.71 17,400 0.76 1.78 16,300 0.77 1.38 a U^° 80/67 18,800 0.69 1.38 18,300 0.73 1.74 18,000 0.76 1.64 16,700 0.78 2.19 15,300 0.80 1.33 E'1P19 Q 75/63 17,400 0.74 1.33 16,900 0.78 1.47 16,700 0.81 1.58 15,500 0.83 1.65 14,200 0.85 7.28 a 75/57 16,400 0.83 1.30 16,100 0.88 1.44 16,000 0.91 1.55 14,900 0.93 1.61 13,600 0.95 1.25 85/72 23,200 0.65 1.66 23,100 0.70 1.90 23,100 0.74 2.08 22,300 0.76 2.20 21,400 0.77 1.90 a N 80/67 22,900 0.69 1.65 23,000 073 2.03: 23,000 0.76 2.06 21,700 0,79 2..51 20,300 0.81 1.69 E'IP24 4 75/63 ' 22,700 0.74 1.65 22,000 0.78 1.84 21,400 0.81 1.99 20,100 0,83 2.06 18,800 0.85 1.76 75/57 22,300 0,83 1.64 21,500 0.88 1.82 20,800 0.91 1.95 19,500 0.93 2.02 18,200 0.95 7.72 85/72 31,900 0.66 2.74 30,700 0.70 2.46 29,700 0.73 2.72 27,900 0.75 2.81 26,200 0.76 3.02 a 80/67 30,100 0.68 2.12 28,900 0.72 2.03 28,000 0.75 2.61 26,300 0.77 2.51 24,700 0.78 2.91 U E'1P29 Q 75/63 2Z900 0.79 2.11 26,800 0.80 2.34 25,900 0.80 2.51 24,300 0.82 2.60 22,800 0.84 2.80 v 75/57 2Z100 0.82 2.07 26,000 0.87 2.29 25,100 0.90 2.46 23,600 0.92 2.55 22,200 0.94 2.74 85/72 42,100 0.61 2.40 39,890 0.64 ' 2.86 38,200 `0.67 3.22 35,650 0,70 3.61 33,100 0.73 3.99 a 80/67 39,900 068 2.38 37,010 0.73 2.85 34,800 0.76 3,21 32,750 0.79 3.58 29,500 0.81 3,95 i E'1P36 75/63 37,900 0,71 2.36 34,727 0,75 2.82 32,300 078 317 29,600 0.82 3.53 26,900 0.86 3,88 75/57 35,800 1.00 233 32,570 1.00 2.77 30,100 1.00 311 27,150 1.00 3.47 24,200 1.00 3.82 85/72 46,800 0.65 1.66 44,900 0.68 2.91 43,500 0.71 3.86 41,000 0.73 4.02 38,500 0.74 6.17 a U7 80/67 44,500 0.67 1.65 42,500 0.70 2.03 41,000 0.73 3.73 39,600 0.75 2.51 38,200 0.77 6.13 E'7P43 v 75/63 44,200 0.68 1.65 40,600 0.74 2.75 37,900 0.78 3.59 35,600 0.80 3.72 33,400 0.82 5.71 75/57 40,800 0.71 1.64 38,600 0.80 2.70 36,800 0.87 3.51 34,600 0.89 3.64 32,400 0.91 5.60 85/72 61,100 0.63 3.56 57,870 0.6.5 4.50 55,400 0.66 4.57 ' 52,000 0.69 5.03 48,600 ' 0.77 5.48 °' 80/67 56,800 0.69 3.49' 53,230 0.71 4.06 50,500 0.73 4.50 46.800 0.76 4.95 '43,100 0.79 5,39 E'1P49 Q� 75/63 53,300 0.72 3.44 49.447 0.75 4.01 46,500 0,77 4.44 42,800 0.80 4.92 39,100 083 5. 9 75/57 47.000 1.00 3.39 43,713 1.00 3.95 41,200 1:00 4,38 38,500 1.00 4.85 35,800 1.00 5.31 85/72 69,800 0.61 4.02 66,457 0.63 4.75 63,900 0.64 5.30 59,950 0.67 5.87 56,000 0.69 6.44 a to 80/67 65,400 0.68 3.96 61,490 0.70 4.72 58,500 0.71 5.30 54,600 0.74 5.83 50,700 0.77 6.36 E'1P49 a< 75/63 61,400 0.71 3.90 56,923 0.73 4.59 53,500 0.75 5.12 49,650 0.78 5.70 45,800 0.81 6.27 75/57 45,400 1.00 3.83 46,760 1.00 4,54 47,800 1.00 5.09 45,600 1.00 5.67 43,400 1.00 6.24 Note. Extended data shown is actual for mode/s listed and typical for all AHRI matches. * =B or L B=Wire Guard L=Louvered Page 15 4a�'i l,I DY a CONDI ,ION ACCESSORIES DESCRIPTION _ WHEREUSEI '''. CATALOG NUMBER Crankcase Heater 18,24,30,36 93M04 Crankcase Heater 42,48,60 93M05 Hard Start Kit 18 10J42 Hard Start kit 24,30,36,42,48,60 88M91 18,24,30,36,42,48,60 34M72 Compressor Low Ambient Kit 18,24,30.36 14W00 Sound Blanket 42,48,60 14W01 Short Cycle Protector 18,24,30,36,42,48,60 47J27 Freezestat 3/8"tubing 93G35 Freezestat 518"tubing 50A93 Time Delay Relay 18,24,30,36,42,48,60 58M81 3 Loss of Charge Kit 18,24,30,36,42,:48,60 84M2 TXV Kit 18-36 A4TXV01 TXV Kit 42-60 A4TXV02 4LLIED TM Air Enterprises 1-800-448-5872 AI'.specf'.cat lons and'I'''.ustrations sub,ect to change without notice and without incur(ng obi,gations. Printed',n the US.A. FORM NO.4AC13-100(10/2017) ©2017 A'.I•ed A Fnterprisec LLC,a Lennox Internatonal Inc.Company Page 16