SGN2001-00039 CITY OF TIGARD SIGN PERMIT
A� a
DEVELOPMENT SERVICES PERMIT#: SGN2001-00039
13125 SW Hall Blvd.,Tigard, OR 97223 (503) 639-4171 DATE ISSUED: 2/21/2001
EXPIRATION DATE:
BUSINESS NAME: LOWE'S HARDWARE PARCEL: 2S101AC-01901
SIGN LOCATION: 12615 SW 72ND AVE
APPLICANT/AGENT: ZONE: C-G
BUSINESS TAX NO: JURISDICTION: TIG
SIGN
PERMANENT: X FREESTANDING: FREEWAY:
TEMPORARY: WALL: Y ELECTRONIC:
OTHER: BILLBOARD: BALLOON:
SIGN DIMENSIONS: 2'X 18'
TOTAL SIGN AREA: 36 sq.ft.
WALL AREA: 9,600 sq. ft.
WALL FACE (DIRECTION): W
SIGN HEIGHT: 2 ft.
PROJECTION FROM WALL: 8 in.
ILLUMINATION: INT
DESCRIPTION OF SIGN: Installation of(1)one 36 sq ft permanent wall sign.
MATERIALS: ALUM
EXISTING SIGNS: 1
ELECTRICAL PERMIT REQUIRED: Y
BUILDING PERMIT REQUIRED: N
ADMINISTRATIVE EXCEPTIONS:
TOTAL PERMIT FEES: $ 50.00
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes
and all other applicable laws. All work will be done in accordance with approved plans. A sign permit shall expire 90
days from approval date. A temporary sign shall ex ire 30 days from approval date. A balloon sign shall expire 10
rlavc from annrnval data APPROVED
APPROVED BY: /
PERMITTEE SIGNATURE:
DATE: 2/21/2001
Y�
7f'-0 SIGN PERMIT APPLICATION
CITY OF TIGARD 13125 SIV Hall Blvd.. Tigard, OR 97223 (503) 639-417/ FAX: (503) 684-7297
GENERAL INFORMATION
Name of Development/Project
Site O w S z v.41%0 FOR STAFF USE ONLY
Address/ Street Address
Location
12 S cJ �vePermit No.: S Git)Z s, � —y 602) g
Suite/Bldg.# City/State Zip +
�-- Expiration Date: ,
OTZ-
Name Receipt#:
Property EF*4Lt bW P4r- G Approved By:
Owner Mailing Address Suite Date: u.� f
Q lawEcc_ Map/TL#: �YDD
City/State Zip Phone, Zoning: U Wit'" >
WR q8 V25-22I S-7Y
Tenants es Name
Business Electrical Permit Required?�� ❑ No
Y, _
L-O t.✓E ,
Name Building Permit Reguired�, : ❑ Yes s No
�v Ccs
Sign AveouAae Rev.12/1/2000 i:\cu ln\masters\revised\si n permita doc•- -
S�v
Contractor Mailing Address Suite
(Prior to i suan e,armit 66 f�., 01-1 q�
copy of all City/State zip Phone
licenses are REQUIRED SUBMITTAL ELEMENTS
( �
required if VOAWGIrl"es— U6 05 q}7 3 (Note: applications will ngA be accepted
expired in the Oregon Const.Cont.Board Exp.Date without the required submittal elements)
City of Tigard's License#1 y� ' I .?q/o Z
database)
Completed Application Form
Proposed ® Permanent EJFreestanding ❑ Freeway
Sign ❑ Temporary R'wall ❑ Electronic 2 Copies of Site/Plot Plan, Drawn to Scale
(Check all that ❑ •(3 copies,if a building permit is required)
apply) Other ❑ Billboard ❑ •
Balloon size requirement: 81/2"x 11",or 11"x 17"
[�t New sign? ❑ Alter to existing sign? ❑ 2 copies of elevations, drawn to scale
Sign Dimensions: , (3 copies,if a building permit is required)
Z K {& size requirement: 81/2"x 11",to 24"x 36"
Total Sign Area (sq. ft.): -3,G
fV $50.00 Fee (Permanent sign, any size)
Sign Data Total Wall Area (sq. ft.) ❑T $15.00 Fee (Temporary sign, any type)
o *6 o 1400 '
(Complete all Direction Wall Faces (circle one):
items in this NOTES:
section) N S E NE NW SE SW
♦ Wall signs do not need to be drawn to scale,
Height to top of sign (feet): 2 ' but must include dimensions of wall face and
Projection From Wall (inches): g e1 sign placement.
Copy: NDoow W *W Yip ♦ Wall signs do not require site/plot plans.
Materials: .4L0'A4.t10uM ♦ Freestanding signs over 6 ft. required a
Will sign have illumination? a Yes ❑ No
building permit.
Type: ' a Internal ❑ External • If work authorized under a sign permit has not
Are there any existing freestanding or wall signs at this been completed within ninety (90) days after
location, including wall signs that overlap a tenant space? the issuance of the permit, THE PERMIT WILL
EJ Yes [:] No BECOME NULL AND VOID.
If"yes", a list or diagram of all sign dimensions and (OVER FOR SIGNATURES)
square footage must also be submitted.
I hereby acknowledge that I have read this application, that the information given is
correct, that I am the owner or authorized agent of the owner, and that plans submitted are
in compliance with the City of Tigard.
DATED this day of ?-eexuAP y . 20 01
Signature of Owner/Agent
PUJ r.>,.1
Contact Person Name Phone No.
Receipt #: 27200100000000000723
_.. Date: 02/2112001
T 1 0 E M A R K
COMPUTER SYSTEMS, INC.
Line Items:
Case No Tran Code Description Revenue Account No. Amount Due
SGN2001-00038Sign Permii 100-0000-437000 $50.00
SGN2001-00039Sign Permit 100-0000-437000 $50.00
SGN2001-00040Sign Permit 100-0000-437000 $50.00
SGN2001-00041Sign Permit 100-0000-437000 $50.00
SGN2001-00042 Ign ermlt 100-0000-437000 $50.00
Payments:
Method Payer Bank No Acct Check No Confirm No. Amount Paid
Check VANCOUVER SIGN CO 0 24201 $250.00
TOTAL AMOUNT PAID: $250.00
E A
HARLAN LAWS
I C 0 R P 0 R A T 1 0 N
Signa of Success
U.S.70&NC 98
Interchange
SOUTH ELEVATION Drawer 15070
SCALE:1/64"= 1'
Durham, N.C.27704
T. 919.596.2124
F. 919.596-0421
E. Info@hadanlaws.com
www.hadanlaws.com
This design is the
=1 property of Harlan
9 11 nnin 11 n 11 11 11M _41*1� IIL Laws Corporation
and cannot be used
or distributed
NORTH ELEVATION , c g D v • S Q- f r• - 3 Zo n 3 D without the approval
SCALE:1/64"=1' = q 6 o a 4 of said company
B 36 * Project:
LU U At
i� A-t,Low ats l,E f s (D AJ A 6 r- l.� �(o � � �
Tigard,Oregon
Phase:
EAST ELEVATION ❑ Conceptual
SCALE:1/64"=1' ■ Design Development
0
❑ Final Production
Date: 12-19-00
Drawn by: S.A.
L000%0 t TY Scale: AS NOTED
App rr' ad..............
.......
2 (,�.,Afl(jil
I
7 :rsw
012-107
t F�t?tb41T NO
- [
WEST ELEVATION 3Z� �ALLoo1,Q� - Revision: 01-23-01
�,s+s le.«r tc� Follow._..-..-.._.............................
SCALE:1/64"= 1' Title.
�,�a f;.,. � � Building Elev.
y' -__ – __ $ �. Z h— Page#:
G.2
F__0_"
i
° WnA C0
° RP0R LAWS
C O H P O N A T I O N
Signa of Success
U.S. 70&NC 98
SCALE: 1/2" = 1'-0" Interchange
Drawer 15070
n SPECIFICATIONS: NOTES: Durham, N.C. 27704
1919.596.2124
Sign Area: 36.00 sq. R. Electrician: Must supply all electrical and hook up of F. 919.596-0421
Quantity: One(1) all signage. E. Info@hadanlaws.com
www.harianlaws.com
Colors: Cabinet: (gg 172 a-3 Blue) Finished in acrylic urethane enamel
Stripe: (PMS#200 Red) Finished in acrylic urethane enamel
Copy:White 2"aluminum channel This design is the
property of Harlan
Construction: Single face internally illuminated cabinet fabricated of Laws Corporation
aluminum(.080 face, .063 returns,8"depth). Copy routed out and
backed with 3/16"thick acrylic. Existing frame and cannot be used
8"return or distributed
Illumination: Internal illumination by high output fluorescent lamps without the approval
Primary to exit out back,thru wall.All wiring U.L.Approved. Threaded rod Thru-bolt& of said company
Seal holes
Installation: Cabinet mounted on steel framing as shown.
Project:
Electrical Requirements: UI2161 Article 600 NEC paragraph 23. Service door
(1)20 amp ground fault circuit @ 277 v. Ln 12
Interior Tigard,Oregon
Exterior
Phase:
SECTION @ SIGN CABINET ❑ Conceptual
■ Design Development
❑ Final Production
Date: 12-19-00
Drawn by: S.A.
Scale: AS NOTED
CD
Dwg.#: 012-107
Revision: 01-23-01
Title: Sign C
LOADING CANOPY ELEVATION Page#: G.6
Scale 3/32"=1'-O"