PFI2017-00279 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
!is COMMUNITY DEVELOPMENT Permit#: PF12017-00279
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 01/03/2018
Parcel: SEG734
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: SEG734,Associated with address 11730 SW 95th Avenue. PGE Job M2409413. 2 Pole Set to fix
VD/Flkr Issues and Aerial Crossing. Open Delta OH Service.
Owner: FEES
Description Date Amount
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
AMY SWEANY
10800 SW AVERY ST.
TUALATIN, OR 97062
PHONE: 503-612-2935
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant II �
Signature: Q Q , li l 1 b
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12017-00279
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI—Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI—Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs. pavement markings, mailboxes, etc. shall be
reinstalled or replaced, with like kind of material. Obtain City approval of restoration work.
PFI—Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI—Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI—Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345 (Tigard School District)and other service providers impacted by such closure.
PFI—Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI—Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI—Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI—Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI—Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI—Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work. Applicant shall coordinate the work
with affected utility agencies.
PFI—Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17- NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit. Call Ken Fisher at 503 816 6146 or Kenny@tigard-or.gov
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
DEC 2 6 2017
City of Tigard CITY OF TIGARD
PLANNING/ENGINEERING
PUBLIC WORKS —ENGINEERING
Public Facility Improvement (PFI) Permit
TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way)
TYPE 1—Franchise Utility Work
Check one: gUtilides ❑ Sidewalk/driveway approach ❑Streetimprovements performed by NWN, PGE
Detailed description:
PGE Job M2409413 and/or utility agency.
2 Pole Set to fix VD/Flkr Issues and Aerial Crossing. ❑ TYPE 2–Sidewalk/Driveway/Sewer
Open Delta OH Service Work performed for the purpose of:
• Sidewalk installation or repair.
• Driveway approach installation
Property address/location(s): 11730 SW 95th Avenue and/or repair
Tigard, OR 97223 • Sanitary sewer lateral installation
and/or main line tap
Applicant: Portland General Electric[Submitted by Amy Sweany] F-1TYPE3—Full scale Development
pp Work performed with Land use
Address: 10800 SW Avery St. approval which includes any of
City/state: Tualatin, OR Zip: 97062 the following:
Phone: 503-612-2935 Email: preregcoord@pgn.com • Subdivisions or Partitions
Contact name: SDPM James Chrisman Phone: 503-736-5749
• Street widening
• Mainline installation for Sanitary
)
(
Contractor: PGE See Above sewer, Storm sewer, Tigard water
and/or Tigard Water Service Area
CCB#: Expiration:
Address: SUBMIT COMPLETED APPLICATION TO;
City/state: Zip: City of Tigard
Planning/Engineering
Phone: Email: 13125 SW Hall Blvd.
Contact name: Phone: Tigard,OR 97223
Applications for"minor work in light-of-way"
Engineer: N/A only may be emailed to:
rowpennits a,tigard-or.gov
Address:
FOR ONLY
City/state: Zip: f 1-
Phone: Email: Case No.: t`1�0 13 -002
Contact name: Application submittal fee: $ 42-'
Additional fees: $
Estimated value of work is required(if over$5,000):$ 13,613.01 Application accepted:
(witlun the public right-of-way) By: A Date:
Application reviewed:
Is work related to a LAND-USE DECISION? ❑ Yes IO No
If so,please specify (MLP,SDR,SUB, etc.) case#: By: & UL�Date:
Applicant notified: I
Is work related to a BUILDING PERMIT? ❑ Yes EKY No By: S� Date:
If so,please specify(BUILDING PERMIT)case#: i:\ENG\Permitapplications\pfE_application Rev.12/16/2016
t _ ....._ ,,,,.. .,.. ... .. ....................� s„�.. .m....,,.x..n..»,iS.«&xi .wr,.,.... .x... .._,. .».......,. ,.,,,...,,. ._...,.......»,..�.»';?»,,l3' aY
City of Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 wwwtigard-or.gov 503-718-2421 • Page 1 of 4
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if
required by the city pursuant to TMC 15.041.140.
* With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different
people,the applicant must be the purchaser of record or a lessee in possessiou with written authorization from the owner or an agent of the
owner. The owner(s) must sign this application in the space provided or submit a written authorization with this application. Franchised
Utilities are not required to obtain the owner's signature on the application
BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT:
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject
ro.ert .
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any peri-nit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
12 01
Applicant/Authorized Agent's signature Print name Date
SIGNATURES of each owner of the subject property, if required.
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov 503-718-2421 Page 2 of 4
l E C E `fix 4� b,
DEC 2 S 2017
CITY OF Y,rl- r)
PLAN NING/Et• G1*,A;EERIN(;�
Page 84 2011 Edition
Stationary Lane Closure with Flagging Diagram 320
Diagram 320 covers total closure of one lane of a two-lane, two-way
roadway. See the detail inset for the layout if using a single flagger to control
both directions of traffic on low volume roads (less than 400 ADT)with good
sight distance as discussed below.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Flaggers at each approach are required if any of the following
conditions exist:
a. Night Operations.
b. Work space is over 200 feet in length.
c. Sight distance is less than 750 feet from each approach
through the lane closure.
d. Traffic volumes are greater than 400 ADT.
4. The length between the Flagger Ahead signs shall not exceed one
mile. Use Diagram 340— Lane Closure with Pilot Car if exceeding one
mile.
5. Cones should be used to outline the work space when curves or other
roadway alignments prevent clear direction for the motorists to pass
the work space safely.
6. Cones along the work space are recommended when posted speeds
are 45 mph or greater, when working under heavy traffic or when travel
lanes are narrower than 11 feet.
7. Extended queue signing (see Diagram 5-4) should be used when
traffic queues extend beyond the initial advance warning sign.
8. When flagging near an intersection, the"Flagger Ahead" (CW23-2)
sign should be visible to traffic entering from any side road. Additional
advance warning and Flagger Ahead symbol signs may be placed on
the side road(s).
9. Sign set-up and flagger placement shown may be used for intermittent
full road closures of 20 minutes or less.
10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should
be considered on high volume or high speed roads, or when extended
queues are expected.
Chapter 5 September 2016
----- -------------- ry
Cn 1 a
C I
CD
�^ I Sinle Flager Operation I '
d J,, ,
o vai t. uWi o N o I gg ( M
for Low Volumes I (Optional) 0 0-
CD
w I (ADT<400) m smP59>I �} O
N v an W ``' I I BE ..:
a o 0 o L�
0 0 0 a a ^ FsAccER PREPARED ONE LANE
CL A;.s b s A c s: TO STROAD
OP
a AHEAD
o U, o w W
O O O O m
m — — — r — — — • ROAD
AH
WORK
� n
K +i K K I AHEAD
o a ca a
� I c\ �1 aSAW
I o
M m � " G o � N� M I � I]RR wfSw I N
I
IQ AF�AD
roptknen I [—A B B
I------------------------ Tt :+
1
1 mile I -n`
f max. —1 tt1
C B B A
Buffer
Protection Vehicle
wl TMA(both Optional}
WORK See Chapter 4
AHEAD; BE (Q
ONE LANE
RO
P s%o� Two Flagger Operation -U
AH TO wCD
UI (Optional) O 0
m
F t+ J. ..�.►.
M
Z .J
G)
OVERHEAD LEGEND
• .. "` M INSTALL FACILITIES
C1
'. ________ INSTALL 2-#2 ACRS OH PRIMARY&
1-#2 ACSR LOW NEUTRAL
I__........__...._.... .:.,R - -- INSTALL 1-40 AL-OX OH SECONDARY
4551 .e iiTK: i a • ^d10 INSTALL CUTOUT
PL�SSi: zDo-03 • .......... SIZE FUSING AS NOTED
INSTALL B-PHASE AVIAN COVER -
RLMOVi 36170 200�1
12MAOV
O i - f
...... A50 60001 % -. .......... _......__.....__........ POLES
0 3
S
1 54 POLE CLASS(l,2,3,4,Hl,H2,S)
.........ITJ ...... .....
POLE HEIGHT(FEET)
::ar:• 020m03 O FRAMING TRANSMISSION 8 DISTRIBUTION(SEE CODES BELOW)
........... .............
D37
FRAME DISTRIBUTION-LC10729,MU 0037
AVIAN (JPH LOFT SGL IT,TANG,PIM
ryry yy //^^ FRAME DISTRIBUTION SLACK 2,MU POLY)(2PH BFT IT Oel DE,SLACK SPAN,POLh
�Z C1i--35D
3z • ANCHORS o
W
x W
8'LEAD
5
O. 'B`7 1,375 LBS)
- ANCHOR CODE At A3 A5 A7 A8
In
_ _ GUYING x = i u
s1988 ................. -..... ................ .......- -.............. O O O O u0 0
-._..__2.142 CO F25T 0 G76 (PRI-1,375 LBS)
f A50
' uACK sPAN
9p
-- -- -- --- �jBio INSTALL A7 PL-59 7200V
PL-55 " 1 GUY GI G4 G7 GI i GI 22
SOKVA A 12 IOKVA 8 g 12()240V T GUYS c2 Gs GS GT1 n 23
3 GUYS G7 G6 G9 GI 1 G2 24
s `
412
n:m EXISTING METER SERVICE
£ 3 PHASE 12M40V
i OPEN DELTA CONNECTED LOAD b:
44.BKW PHASE LOAD
VT v5
6.3M 3-PHASE LOAD
.......TIP ......._.... ....._ --_.-._.-..
REMOVE AERIAL CROSSING
35-5
_.... _......
880e .............
CONSTRUCTION NOTES: OH
40
•
I. SEE THE PGE ELECTRIC SERVICE REQUIREMENTS(ESR)BOOK FOR THE FULL SEE
Of REQUIREMENTS.THE ESR BOOK CAN BE FOUND AT hnpr/�.-w+.pardandRenerol.com
• "" "- I Z. CUSTOMER IS RESPONSIBLE FOR ORTNNING ALL BUILDING AND ELECTRICAL PERMITS FOR
.-....-.._.................._.._- THE APPROPRIATE MUNICIPALITY.CUSTOMER IS ALSO RESPONSIBLE FOR ORATINING ALL
1 EASEMENTS AND TREE-TRIMMING PERMITS,AS REQUIRED.
3. ALL TREE TRIMMING IS REWIRED EO BE COMPLETED PRIOR TO PGE INSTALLING SERVICE.
4. CONTACT PGE SERVICE COORDINATOR IN ORDER TO RECENT AN APPROVED METER
SPOT AND CONFIRM THAT THE SERVICE WILL MEET ALL APPLICABLE CODE CLEARANCE
REONREMENTS OVER GOUND.STREETS,PARKING LOTS,ROOFS,DECKS AND BALCONIES,
ACROSS OR BESIDE OTHER OVERHEAD UNUrY WIRES.ANO ADJACENT TO WINDOWS.
,.... •... `_.-__ ....-....... ............ ..._...........__. ................ ............. 5. AFTER PASSING THE APPROPRIATE MUNICIPAL ELECTRICAL INSPECTION,
-- CUSTOMER TO RfOUESI AN INSPECTION 8Y PGE BY CONTACTING A SERVICE COORDINATOR
AT 800-542-.8818 OR 503 323-6700 IN THE PORTLAND AREA PGE WILL NOT ENERGIZE
IF THE SERVICE UNTIL ALL INSPECTIONS HAVE BEEN PERFORMED.
PGE CONSTRUCTION DRAWING
AS-BUILT VERIFICATION & NESC VIOLATIONS CORRECTED
IM-55 IM-59 errs This do-mem accu,alely represents FIELD Construction,
INSTALL: INSTALL: SAFBTY Foreman: Date:
FIPJM General Foreman: Date:
45-3 (Signature only required for field construction changes.)
50-3 SDPMIENG REVIEW: JASBUILT BY DESIGNER:
'1/} CONTACT SERVICE COORDINATOR DAM. 12/2a17 SCALE:NTS ACC—r 1070001 AWO:1000004545 oe NO M2409413
107 D37 FOR TRENCH AND CONDUIT INSPECTION PRIOR
LINE WI
IO AACKFR1 PGE LL NOT INSTALL WIRE nTLF
LINE
uNrx TRENCH a nox AACKnI_ED. PGE—John Stevenson
SERVICE COORDINATOR CIRCUO SIZE
503-323-6700 OR 800-542-8818(SALEM) TIGARD-13361 17x22
WEST
107 BUCK ATTENTION CALL 811 BEFORE YOU DIG PG� O7CA I30 S
8'L OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED - n' II730 SW 95TH AVE,71GARD,OR 97223
Al
1,375# BY THE OREGON UTILITY NOTIFICATION CENTER. DESCRIPTION
THOSE RULES ARE SET FORTH IN OAR 952-001-0010 ` 2 Pole Set to fix VDflkr Issues and Aerial Crossing.Open Delta OH Service
B-PHASE AVIAN COVER G16 PRI 1,375# THROUGH 952 001 0090 YOU MAY OBTAIN COPIES OF COUNTY FCT/oms) WORK WITH SHEET
THE RULES BY CALLING THE OREGON UTIUTY eEAVERroN WASHINGTON C11350 T of I
NOTIFICATION CENTER ADMINISTRATION @ (S03-232-1987)
LINE CREW CENTER DESIGN BY PHONE(503J DRAWN BY
B-PHASE AVIAN COVER TO REQUEST UTILITY LOCATES CALL THE OREGON Know whats below. LAMES CHRISMAN 736-5749 CESAR DEL ROSARIO
UTILITY NOTIFICATION CENTER,811 AT LEAST Call before you dl �RTa+
T BUSINESS DAYS PRIOR TO EXCAVATION. y 9• O PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED