Plans (43) SCOPE OF WORK FIRE EQUIPMENT SYMBOL LIST goo gO, MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM ����'p y� SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT �'o m WHICH INCLUDES THE ADDITION OF DUCT DETECTOR MONITORING, Y NOTIFIER 'Se HORN/STROBES, AND STROBES. I7 FIRE ALARM CONTROL PANEL NFW2-100 REV 3 EXISTING EXISTING g o EXISTING N O V 22 2017 I FIRE ALARM CELLULAR COMMUNICATOR 30401 OCF EXISTING EXISTING 1 j EXISTING CITY OF TiGARD NOTIFIR n REMOTE FIRE ALARM ANNUNCIATOR N-ANNE80 EXISTING EXISTING �z BUILDING DIVISION EXISTING ©� GENERAL NOTES n SPRINKLER FLOW SWITCH (BY OTHERS) BY OTHERS MONITORED BY NMM-100P 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA Q SPRINKLER TAMPER VALVE (BY OTHERS) BY OTHERS MONITORED BY NMM-100P i V% e 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE NOTIFIERi--1 THAN ONE FLOOR SHALL BE RISER RATED. ® ADDRESSABLE MINI MONITOR MODULE NMM-100P MOUNTS INSIDE 1-GANG MOUNTS INSIDE 1-GANG 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. a NOTIFIER 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND O4 ADDRESSABLE RELAY MODULE NC-100R EXISTING EXISTING LIGHTNING PROTECTION DEVICES. EXISTING Ce 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL. BE MECHANICALLY NOTIFIER �/ PROTECTED. FD MANUAL PULL STATION - ADDRESSABLE NOT-BG12LX EXISTING EXISTING Id. 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS EXISTING "FIRE ALARM CIRCUIT". NOTIFIER 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE 2qPA 72). PHOTOELECTRIC SMOKE DETECTOR NP-100 EXISTING EXISTING co 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION OFFICF,V COPY EXISTING OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). iii NOTIFI0R IX 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR 1� FIXED TEMPERATURE HEAT DETECTOR NHS NG EXISTING EXISTING Ii AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH EXISTING Q SECTION 14.6.2.4 (NFPA 72). CITY OF TIGARD 6 DUCT SMOKE DETECTOR BY OTHERS MONITORED BY NMM-100P 1 REVIEWED FOR CODE COMPLIANCEHORN/STROBE - WHITE SYSTEM SENSOR 4' SQUARE, 4" OCT, SINGLE OR �" MIN TO LENS BOTTOM AFF Cl) El (NAC AND CANDELA NOTED AT DEVICE) P2WL DOUBLE GANG BACK BOX 96' MAX TO TOP OF LENS AFF ♦ ' Approved: 6' MIN TOP OF LENS TO CEIUNG OTC: 1 I _ STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR l (NAC AND CANDELA NOTED AT DEVICE) SWL DOUBLE GANG BACK BOX 80" MIN TO LENS BOTTOM AFF A 90" MAX TO TOP Or LENS ATF Permit#: 71),c a pi-7 —Q 0 ) IL T C El CEIUNG MOUNT HORN/STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT, OR DOUBLE rEII# vsUR LENS TO CEILING 0 1� Address: i 9j l3 S 704-h A✓ '�' (NAC AND CANDELA NOTED AT DEVICE) PC2WL GANG BACK BOX W C CEIUNG MOUNT HORN/STROBE - RED SYSTEM SENSOR 0 I— SUite#: PC2RL EXISTING EXISTING O SITE ��_ �- EXIST (NAC AND CANDELA NOTED AT DEVICE) EXISTING Q �/J Br Date: 7 GENTEX Z Q AB 24 VOLT WATER FLOW BELL GB6-24 EXISTING EXISTING Z (7 - - EXISTING W I•= V J SW DARTMOUTH STREET DOCUMENT ENCLOSURE WITH INTERNAL SPACE AGE W - � • DOC SSU00685 EXISTING EXISTING 0 m z G sIP irI —_- ■ =1�----� op—iFLASH STORAGE EXISTING �/ i�• , ' m -b- z BUILDING A I ♦W♦ W Q LL V Z ' �tz 2 �141 '1='�– _ - m LLT = J Iia M. .r. V o O II m _ Q U ti "f - . t �p I „ .11it�r w TELEDATA `' �' W ' I I v II I I I �� z w �. •.`` �' SYMBOL DESCRIPTION Q � N LL z > j/// �//// J., I uni141 z PHONE JACK REVIEWED/APPROVED:, a II / �i,e�BUILDING C �� � REkt, OF WORK //i/% // N ‘ -- ----CQ1-- I 9 c .1 I ////i j/// DWG REVS/DATE I — ® / 0 11/21/17 I I 1i II e,I ' i / , I �i �1 '— I ���,�5��/ 1 1 t I BUILDING C - FLOOR 2 DRAWN BY: �� A NGM I"- ! '— /r � �`_ CHECKED BY: I - - - - i a BJB I � , FILE NAME: ELMHURST ST. DEDICATIONI AREA OF WORK FA.dwg I I �� 1 w NOT TO SCALE DRAWING#. FA-1 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 1 OF 5 BATTERY CALCULATIONS NOTIFICATION CIRCUIT SCHEDULE gtom 4 NOTIFIER NFW2-100 REV 3 (ELEC RM) VOLTAGE DROP CALCULATIONS W(2g PART # DESCRIPTION OW STANDBY STANDBY TOTAL ALARM ALARM TOTAL CKT # DEVICE LOCATION / AREA CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT o ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP % NFW2-100 MAIN CIRCUIT BOARD 1 0.1450 0.1450 0.2750 0.2750 5 N-ANN-80 REMOTE ANNUNCIATOR 1 0.0150 0.0150 0.0400 0.0400 N-1 HORN/STROBE FLR1- HALL 108, LOBBY 100 FACP 0.217 130 14 0.17 20.23 YES 0.85% NOT-BG12LX PULL STATION ADDR 1 0.0004 0.0004 0.0005 0.0005 N-2 HORN/STROBE FLR2- LOBBY 200, ADVANCED ENDO FACP 0.764 490 14 2.30 18.10 YES 11.27% NP-100 PHOTOELECT ADDR HEAD 5 0.0003 0.0015 0.0065 0.0325 N-3 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% N-4 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% Z NH-100 HEAT DETECTOR HEAD 2 0.0003 0.0006 0.0065 0.0130 NMM-100P MINI MONITOR MODULE 6 0.0004 0.0024 0.0050 0.0300 *****END-OF-UNE METHOD OF CALCULATION NC-100R RELAY MODULE 4 0.0003 0.0012 0.0065 0.0260 GB6-24 6" WATERFLOW BELL 1 0.0000 0.0000 0.1000 0.1000 1` illi PC2WL HORN/STROBE - 15 CD 1 0.0000 0.0000 0.0710 0.0710 1it 4 P2WL HORN/STROBE - 15 CD 5 0.0000 0.0000 0.0540 0.2700 P2WL HORN/STROBE - 30 CD 1 0.0000 0.0000 0.0740 0.0740 SWL STROBE - 15 CD 5 0.0000 0.0000 0.0430 0.2150 SWL STROBE - 30 CD 1 0.0000 0.0000 0.0630 0.0630 PC2RL HORN/STROBE - 15 CD 1 0.0000 0.0000 0.0710 0.0710 PC2RL HORN/STROBE - 150 CD 1 0.0000 0.0000 0.2170 0.2170 N-3 SPARE NAC 1 0.0000 0.0000 0.0000 0.0000 > N-4 SPARE NAC 1 0.0000 0.0000 0.0000 0.0000 Ce STANDBY TOTAL 0.1661 ALARM TOTAL 1.4980 C *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DERATE STANDBY 0.1661 X 24 = 3.9864 CO - ALARM 1.4980 X 0.0833 = 0.1248 - �/• TOTAL AH = 4.1112 4.9335 Li. BATTERIES TO BE INSTALLED: 7.0 AH Q FIRE ALARM OPERATIONAL MATRIX SYSTEM OUTPUTS 0 P�& g�P4� P�O�P +� O co i ,�a� Q °) w �� •c° �, e 10 c 4. .•z• 0 o �- e2 e2 � ` 0 II ° �0 SG cjP' 0 0e,,+4- .c�Pct 0J4� .2y,ct, Zz < >- cg'P $ A -1 J04 JP�J ,tP et O0 40 caEi � V- e- y `.Y0ke, dciP S� (a J - V� .PQ`QdyQ�yQ .JP4JPtP 6POc.,PPs�,c4, misSYSTEM INPUTS P. � � � � Pa Pv Po Q # P � � � NOTES: Qw N PULL STATION • • • • � � W Q SMOKE DETECTOR - NON ELEVATOR • • • • C.) z III = 1 SPRINKLER FLOW SWITCH • • • • • U O Q SPRINKLER TAMPER SWITCH • • Q Y DUCT DETECTOR • • >( U 00 WN COMM TROUBLE • • Q D_ u) 1.V 0 '- LOSS OF AC POWER AT FACP • • a' `- `'L' OPEN CIRCUIT • • DWG REV.I DATE DISCONNECTION OF BATTERIES • • 0 11/21/17 GROUND FAULT • • SMOKE DET. - ELEVATOR LOBBY MAIN FLOOR • • • • • DRAWN BY: SMOKE DET. - ELEVATOR LOBBY OTHER FLOORS • • • • • NGM CHECKED BY: SMOKE DET. - ELEV MACH RM/TOP OF SHAFT • • • • • •• . BJB HEAT DET. - ELEV MACH RM/PIT/TOP OF SHAFT • • • • • • FILE NAME: SHUNT VOLTAGE MONITOR • • FA.dwg DRAWING#: PRESS SIGNAL SILENCE KEY • • FA-2 PRESS RESET KEY • ORIG.SHEET SIZE:11-x 17' #OF DWGS IN SET: SHEET 2 OF 5 DETECTOR SCHEDULE MODULE SCHEDULE FIRE ALARM RISER DIAGRAM (TYPICAL) 80 0 =meq J Q m ADDRESS DEVICE LOCATION / AREA ADDRESS DEVICE LOCATION / AREA f° D-1 PHOTO FLR1, ELECTRICAL ROOM 106 - AT FACP M-1 SPARE SPARE w w D-2 SPARE SPARE M-2 MONITOR FLR1, ELECTRICAL ROOM - COMM TROUBLE 5 D-3 SPARE SPARE M-3 FLOW FLR1, MECH/SPRKLR RM 105 - WET FLOW AT RISER ;g D-4 SPARE SPARE M-4 TAMPER FLR1, MECH/SPRKLR RM 105 - WET TAMPER AT RISER © 0. 0 dM D-5 SPARE SPARE M-5 TAMPER FLR1, IN VAULT - DBL CHK VALVE ( -- D-6 SPARE SPARE M-6 SPARE SPARE TYPICAL PWR al © l IBY OTHERS Q2 D-7 SPARE SPARE M-7 SPARE SPARE 14/2C FPLR / D-8 SPARE SPARE M-8 PULL FLR1, LOBBY 100 - PULL AT MAIN ENTRY SLC TO FACP . , D-9 PHOTO FLR1, AT ELEVATOR LOBBY M-9 SPARE SPARE 18/2C FPLR _ 0i; II%M 8 D-10 PHOTO FLR1, AT ELEVATOR CONTROLS M-10 SPARE SPARE �` D-11 HEAT FLR1, AT ELEVATOR CONTROLS M-11 SPARE SPARE Q D-12 SPARE SPARE M-12 RELAY FLR 1, ELEVATOR RECALL TO MAIN g D-13 SPARE SPARE M-13 RELAY FLR 1, ELEVATOR RECALL TO ALT r- � lt ilit D-14 SPARE SPARE M-14 RELAY FLR 1, ELEVATOR HAT FLASH ELECTRIC ROOM 106 D-15 SPARE SPARE M-15 RELAY FLR 1, ELEVATOR SHUNT TRIP \ AUX 24VDC I 0-16 SPARE SPARE M-16 MONITOR FLR 1, ELEVATOR SHUNT VOLTAGE . SLC 1 6 EOL 44.7k0 0-17 SPARE SPARE M-17 SPARE SPARE r NOTIFIER 2 I o 2 10 2 EOL_4.7k0 ` D-18 SPARE SPARE M-18 SPARE SPARE NFW2-100 T D-19 SPARE SPARE M-19 SPARE SPARE ®FAC FACP 3 ---SPARE EOL 4.7k0Ce D-20 SPARE SPARE M-20 SPARE SPARE ® W/INTEGRAL 4 SPARE EOL e•7k0 1i. D-21 PHOTO FLR2, AT ELEVATOR LOBBY M-21 SPARE SPARE f DACT D-22 PHOTO FLR2, AT TOP OF ELEVATOR SHAFT M-22 SPARE SPARE D-23 HEAT FLR2, AT TOP OF ELEVATOR SHAFT M-23 SPARE SPARE 120VAC DEDICATED CO D-24 SPARE SPARE M-24 MONITOR FLR 2, DUCT DETECTOR (VERIFY LOCATION ON AS-BUILT) L— —1 0-25 SPARE SPARE M-25 SPARE SPARE D-26 SPARE SPARE M-26 SPARE SPARE ICe ***SPARE CONTINUES*** ***SPARE CONTINUES*** TO/FROM FACP Q 18/4C 07-- D-99 I SPARE (SPARE M-99 I SPARE SPARE 1 FLR 1 LOBBY 100 I -1i Cl) I NOTIFIER I I N-ANN-80 I\'-- r L FAA J Z" ' OC•1 or D_ W SLC TO FACP 0 O l- 18/2C FPLR 0 Q Q) g Z a >- r 1 r ELEVATOR EQUIPMENT CLOSET 1 W i ( ) TOP OF SHAFTLLI ©. / RECALL TO MAIN TO W w N OTHER LOBBIES ©_ ,RECALL TO ALT ELEVATOR r ' LL ,HAT FLASH CONTROLS `� Z = SHUNT TRIP Z W MAIN LOBBYim' CABINET Y P SHUNT VOLTAGE PAN SHUNT TRIP V �/ LLI El 0 0 0 0 Et ELEVATOR PIT W j 18/2C FPLR L I L J < 0_ DWG REV./DATE * INSTALLED IF NEEDED 0 11/21/17 NOTE: WIRE TO BE FPL, FPLR OR FPLP PER NEC DRAWN BY: NGM CHECKED BY: BJB FILE NAME: FA.dwg DRAWING A. FA-3 ORIG.SHEET SIZE:11"x 17" it OF DWGS IN SET: SHEET 3 OF 5 888 WFiA R c 00 1 2 3 4 5 • .0 rd It „ti it k • A I 1 1.1 ISI 1 11 Iwin� 11C111 1 //; hz1 .. // , ' " - ' $ ' // WNW 41 3 i' 2 '-' -,VERIFY LOCATION —,-_ / - / /// 1./ /a , — — V- = ---. '-it`4 BY OTHERS - / ' / . .:,. , " j j� / , / i ., N-2.2 / / 1 � / 30CD it:174V / ¶I� 221 14 ✓ i I C / / 1 N-2.5 1 Z31 I N-2.3 / —� '/ T ' , /1 ,i-, /)// .2, . / cC II_LSL.ZJ. i fli !' f ■ r �t I '2D4 I / ' Ce TREATIvIIENT 5 �r -a- _ C/, ZZZZ ��a� f _ / XIS ,/ ;1N •,.:. N-213 - % / Jr „ /X / V C 11I L, A j /j Lf / /' _ / �1 FROM ACP '/ / (/------ N-2.6 1/1 1-61- I itieD N EOL 4 /� / / i�� •/ �/ % / 1 / O, FLRt M // j N f'.Y11IIiIc\ 6 / /Amy/ / //�,— / / „ / / rn CC w I - ®� / nii OFFICE 1 r ����/, / /, /' // ✓ / i ' / 2 // //' 0 o C (/) -223-#1 / / ' / // / / / I �/' / 0 W N-2.9 I N-212 „ir•� . Isco ' 15co �IE'i��ll �.„ � /� x 9%/' � %' / % �/�j72 W o - //y // / „' / // / / / ' /// ,/' / / 5 uf iii illiL7 ( CD 0 NI L I` / , m 1 1-CD ■w■ / / z liG ix , LLI N 27 , --i i ✓ i/ / / - // / / L / W � V 15CD j" / / j = / _. _ ,,,,, . Z. . - ----, / / / y ,/ „ , ,, // / ,•y // ; ,' / / L_Z22J / / / : -,/ II it r; ! :_ ;. - - / � - �/ / �, / / cl ll') , '/'''/'// /: ,/ 1.1 :/ '1;/,'/1:// i N-2.8• 30CD I STAFFT I _ �� '�� /�/' � %� / /� , /✓, // / ,'// -DWG REV.!DATE . = 0 11/21/17 / - , / '/ / • / // ,7 / • , ,2 , // /. ' � / �� /� / / / /DRAWNBY: , _I II 1 II -II II— II l -II II II II 11 E - _ _ // i/ //' / // i � / I NGM ,/ 'r // // ' // / ` CHECKED BY: � „, ___11/ —II II IL-'-- BSB FILE NAME FA.dwg (aki FLOOR 2 0 8, 16' DRAWING#: FA-4 (al / SCALE: 1/8"=1,—0" ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 4OF5 . 8E8 *.Qga qJ •m W N g of iB Ilt 6 • SLC - SLC - TO NEXT DEVICE FROM FACP SLC IN SLC OUT OR OR i PREVIOUS DEVICE (TYPICAL 18I2C) (TYPICAL 1R'2C) TO FACP FOR N o O SLC + • SLC + OPTIONAL CLASS A ii Ce O Ii C MONITOR MODULE Q C cam, ( 1) - - m ,, r�� ,0� o 6 7� nn 6 7 8 �`` • Ohio 11r 1110 r L ADDRESS Ce jl F7 �I I I FROM NAC RSOURCE y + ^, V TO ODEVICE 320 3\-'�j Q PREVIOUS DEVICE ,: i . .i I- _ EOL(4.71(0) 10 100 Or TENSONES 1 NAC - NAC - LOOP NAC IN NAC OUT � Cl)1 •S . r/ (TYPICAL 14/2C) (TYPICAL 14/2C) (—) (+) (+) (—) NAC + NAC + YELLOW VIOLET `RED BLACK [ % - IP , \ / Z TYPICAL 18I2C \. TYPICAL 1820 / Elm 0 N li CNI Co) J EOL CC W O imp:„...„,.---- ��I er, ; 47Kne O O �- OO q, L-! \ 0 IX CAUTION: DUCT DETECTOR Z z DO NOT LOOP WIRE UNDER BREAKMINAL 1.WIRE RUN TO PROVIDE SYSTEM SENSOR (BY OTHERS) LU 2 UNIVERSAL MOUNTING PLATE SUPERVISION OF CONNECTIONS. e 9 S A A e S 9 S = W G 5 SW,P2W,SCW,PC2W CI z 0 z Z 0 Z z A z ' Z O 0 0 0 C) 0 Lu L-SERIES:SWL,P2WL, ALARM TROUBLE SUPERVISORY W SCWL,PC2WL Z Q Q ) SYSTEM SENSOR Z 0I- Q 0 NOTIFICATION DETECTOR MONITOR Q` 0 SCALE: NTS ODUCT SCALE: NTS /el 0 U) ' 0 ' Q DWG REV./DATE 0 11/21/17 DRAWN BY: NGM CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#: FA-5 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 5 OF 5