Report (43) ik...., AV
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: MST 20 l "I- — OO i 1 q Jurisdiction: G 0E- M CDA'f2.,�
Site Address: 1 3 1 g Z %LJ GALt
Subdivision/Lot#: Nb ':TI4 t.%)SST t Vf:g--Tes-2AC�'
and/or
Map and Tax Lot#: I 6 -+
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: 1 /' Date: I 2 ' — n, .:_/, ., . /A .rized Age t
.7
Print Name: LAutdeldor (., .ITL151'E).L ST"'-4.,,L_
t ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official drat be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms>RES HighEfficiaicyLighting.doc 07/01/08
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, ,. Loot CA.1.2_5766.5,1 , am the general contractor or the owner-builder
at the following address:
Site Address: 1 19 Z 42+a cA14-r3, 12-4.4 `s E. —r 0.2Ac t
City: -r'I cA-zi / 81-f f L i co Cs
Permit#: MST 2.011 - bO I 1
Subdivision/Lot#: t`1b2_17 t lJ'E57- T24 TTS-RA-c-6
and/or
Map and Tax Lot#: --+
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and
OAR 918-480-0140,I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: 12. - - 1 3-
/;,/, . r Owner-Builder
I:\BuiMingtFotm\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, AueLt N-4usi5,6 1 , am the general contractor or the owner-builder
at the following address:
Site Address:
. 14;t cAlA&Mai t,4£ "ref2.2.Ace
City: Ti G,A-iilk / Hi oo
Permit#: MST 2.1) 11- — O b l k°1
subdivision/Lot#: o to e"ar ,t Y 'T'�Zf2JkC L�
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
�e ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Joints lapped 12"at seams and
[�Extending up the foundation walls 12".
Signature: Date: 12 - Os - ' 1-
s , .i':PT"or er-B
I:1Buiidmg\Fam\RES-MoistureBarria.doc 09/13/2016