Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (35)
SITE PLAN-OLIVER BLESER PROPERTY LINE co G M( `' O CV CD�q' _200 PMP-MSP ggq�r co 1'.." ° INTERCONNECTION L�3oEg ❑ ,INVERTER DRIVEWAY a 0 z OFFICECOPYo ❑ CO CITY OF TIGARD ° 111 W REVIEWED FOR CODE COMPLIANCE `c. ins ° FApproved v ° et OTC: j R� ❑ 4 ce ° Permit#: 11A° � ��17- 4S2 G�n o `}' ° Address: ij52..- i ren,.t l� r.• �' /` T' ❑ Suite#: alliB _ Dates _ ❑ Laa ❑ • PROPERTY LINE NENERGY W,ip'E Solutions PROJECT INFORMATION s SOLAR OWNER: CONTRACTOR: BUILDING APPLICABLE DATA: ROOF SPECS: SYSTEM INFO: ENERGY SOLUTIONS LLC OLIVER BLESER CODES: EN BOX 887 SINGLE FAMILY 2014 OREGON STRUCTURAL COMPOSITION SHINGLE ROOF (22)SILFAB SLA-310M WATT MONO 12510 SW SUMMER CREST DR. RESIDENTIAL INSTALLATION SPECIALTY W/2X6 TRUSSES DOUGLAS ALL BLACK MODULES BEAVERCREEK,OR 97004 TIGARD OR 97223 503.680.3718 503.597.8477 CODE FIR#2(u 24"ON CENTER 11'9" (1)SOLAREDGE 6000H-US CCB#202002 2014 NEC CODE HORIZINTIAL SPAN ROOF AREA=2695'SQ W/ZIGBEE MONITORING EDGE P320 DC OPTIMIZERS TILT=19 DEGREES SYSTEM SIZE=6.82 KW AZ= 260 DEGREES SYSTEM AREA-_401'SQ<25% LOWEST READING=77% PROJECT NOTES 1. 303.2-PV SYSTEMS AND SUPPORTING STRUCTURE SHALL 6. . CONTINUED...SECTION IS LARGER THAN 150 FEET MEASURED 10. PER 305.4 ITEM 3-TOTAL SYSTEM WEIGHT SHOULD NOT COMPLY WITH REQUIREMENTS OF OSSC CHAPTER 6 OR THE ORSC AS APPLICABLE IN LENGTH OR WIDTH.EXEMPTION IA:WHERE PV ARRAY DOES EXCEED 4.5 PSF.PV MODULES AND RACKING SHALL BE 2. 303.3-ALL PV MODULES TO BE UL 1703 LISTED NOT EXCEED 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF DIRECTLY ATTACHED TO ROOF FRAMING.ATTACHEMENTS 3. 303.5-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION THAT AREA OF THE STRUCTURE,A MINIMUM OF 12"UNOBSTRUCTED SPACING WILL BE 48"ON CENTER MAX.WHEN ATTACHMENT IS IS EQUAL-PV TO ORTE GREATER.THAN THF.ROOF CLASSIFICATION PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF ANY LOCATED WITHIN 3'OF ROOF HIP.EDGE,EAVE.AND RIDGE REQUIRED BY OSSC SECTION 1501.1 HORIZONTAL RIDGE. SHALL BE 24"ON CNETER MAX 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD 11. MAX MODULE HEIGHT WILL NOT EXCEED 12"OFF ROOF 4. 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BF. RATED FOR THEIR USE. CONSTRUCTION WITH 2X4 TRUSSES AT 24"ON CENTER MAX SURFACE 5. 303.4-303.8-PV LAYOUT SHALL NOT RESTRICT EGRESS, EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS IN TABLE 12. SECTION 304.7-MECHANICAL EQUIPMENT'CLEARANCES OF 30" LIGHT,VENTILATION,OR ROOF DRAINAGE 305.4.1 MINIMUM ON ROOF. G. 304.9.1 GE TIL AL PATHWAYS REQUIREMENTS EXEMPTION 1: R. 304.9.5-DISCONNECTS,J-BOXES,COMBINER BOXES OR ON STRUCTURE,WITH A PV ARRAY AREA OF 1,000 SF OR LESS GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAYS pGE METE e y INSTALLED ON A ROOF WITH A SLOPE THAT EXCEEDS 2:12OR CUTOUTS MSP AND WITH AN INTERSECTING ADJACENT ROOF WHERE NO 9. ROOF MATERIAL PATHIS COMPOSITION ROOF,SAR METAL,FOLLOWS _200 13 pMP PRECRIPTIVE IN 2010 OREGON SOLAR CODE 0 ppINT•C1E evi0N Illhh„❑ , i 0 ❑ CO:33 0 tv: i b„i_li pE,. iii Aim 12510 SW Summer o ,3 ,, s-a -013 STANDOFFS ARE ATTACHED EVERY 18"IF 00 ❑ LOCATED WITHIN 3'OF ANY HIP,EAVE,RIDGE, OW . 4011111 OR VALLEY PER CODE. IF OVER 3',STANDOFFS ❑ ,,, ARE ATTACHED EVERY 36"ON CENTER. ENERGY SOLUTIONS, LLC OLIVER BLESER PO BOX 887 12510 SW SUMMER CREST DR. N ENERGY BEAVERCREEK,OR 97004 TIGARD OR 97223 / 503.680.3718 503.597.8477 So�ut�ons CCB#202002 6.82 KW SOLAR ARRAY-RESIDENTIAL W ` E ENLARGED ROOF PLANr _ S PGE METER u ❑ — 200 AMP — MSP POINT OF ❑ INTERCONNECTION — INVERTER • 20' 1'� ` ❑ T. .� I 1 1. 12'6" _o 11 to C7- 0 i ow- ID 45' ❑__ W __ �. •-m - :::. ...�::.✓❑ . •-2 -- ----o--._.o--- ---o--.- -.a.:. j. 0 LOWES READING 17' / 2 571-7, MODULE END CLAMP 2"x6"RAFTER _J_t_� J_I� _J_L_ L. IT I I 1 11 l il j4 f I to LE LAMP COMPOSITION R F 1 I I 1 I 1 1 --- I i i PV MODULE TYP. i / `` -FOOT _���� MODULE MID CLAMP; / I/®� L-FOOT + I 1 I � ' AND" i ' ' ' RACKING RAIL � ---------------AND �� I FLASHING 1 %� f-_I-r - i i i i i i ,/�� 5116"SS LAG SCREW i MIN 2.112"THREAD PENETRATION 11+4" 1 1 t 4 48"MAXIMUM,BETWEEN ATTACHMENTS A MOUNTING PLAN VIEW(PORTRAIT) ®MOUNTING DETAIL PV 8 SCALE. 1"=1'-6" SCALE: 1"=2'-0" 5.25" t.1 ik0C* CpM ,.,- 'r\ I� 2"x6"RAFTER % 1 I tiiiMOUNTING METHOD SCALE: 1"=2'-0" ENERGY Solutions NEW SOLAR PV ARRAY AND ATTACHMENT SYSTEM TO EXISTING ROOF STRUCTURE. 2 ROWS OF MODULES IN PORTRAIT 2 ORIENTATION 161,II Collar Tie: 2 x 4 3g`r i 12ft3in Exterior Wall _ South Elevation Dimensions: • 20° Roof Pitch • Rafters: 2 x 6, 24" O.C. • Load Bearing Walls: 2 x 4 • Ceiling Rafter: 2 x 6 • Table 2308.7.2(1)Allowable span is 12'6"for Douglas Fir#1 RAFTER DRAWING PROJECT REF: Oliver Bleser SITE ADDRESS: 12510 SW Summer Crest Dr, Salem OR 97223 SYSTEM SIZE 6.82 kW 2 Strings of 11 Modules/Optimizers(SilFab Solar 310W/SolarEdge P320) Sheet 3 of 3 Date: November 27, 2017 System Information Labels PV Module Ratings Inverter Ratings Photovoltaic DC Disconnect Module Make SilFab Solar Inverter Make SolarEdge Rated MPP Current = 16.5 A ENERGY Module Model SLA-310M Inverter Model SE6000H-US Rated MPP Voltage = 380 V Max Power = 310 W Max. Output Power = 6000 W Max. System Voltage = 480 V Solutions Open Circuit Voltage = 40.25 V Max. DC Voltage = 480 V Max. System Current = 30.0 A Max Power Point Voltage = 33.05 V Norminal AC Voltage = 240 V Photovoltaic AC Disconnect Short Circuit Current = 9.93 A Max. AC Current = 25 A AC Output Current = 25 A P.O. Box 887 Be Oregon Max Power Point Current = 9.38 A CEC Inverter Efficiency = '139.0% Nominal AC Voltage = 240 V Phone: 5033-680-3718 04 UTILITY 0 © © © © 0 ERVIC 1 ,,'-'\ Junction ®,,/ 11 modules W/ Box INVERTER • +• optimizers in series OCPDMain 200A (at array) O © © CII - -- \C\ —DC —; 1 'I1 35A 11 modules w/ I • optimzers in series• ——z ; —- —�— L—_—1 Main G Service Panel C CI 200A Bus •"'"7:----- � BUILDING GROUNDING ELECTRODE EQUIPMENT SCHEDULE REF DESCRFIION PN NOTES Notes: 1 SOLAR R/MODULE SLA-310M SILFAB SOLAR 310W MONOCRYSTA LUNE MODULE • Equipment, conductors and conduit 2 R/MODULE OPTI IZER P320 SOLAREDGE 320W R/MODULE OPTIMIZER as listed or equivalent. 3 ARRAY MOUNTING HARDWARE TBD FLUSH ROOF MOUNT RACKING SYSTEM • Expected nominal string voltage: 4 JUNCTION BOX TBD FOR TRANSRTON FROM R/WIRE TO CONDUCTORS N CONDUIT 380Vdc. 5 INVERTER SE6000H-US SOLAREDGE 6KW HD WAVE INVItti tx W/DC DISCONNECT ONE-LINE STANDARD ELECTRICAL DIAGRAM 6 MAIN SOLAR OCPD TBD 35A,240V,2-POLE CIRCUIT BREAKER(BACK-FED) 7 MAN SERVICE PANE. N/A 200A BUS WI 200A MAIN BREAKER,240V(EXISTNG) PROJECT REF: Oliver Bleser SITE ADDRESS: 12510 SW Summer Crest Dr, CONDUIT&CONDUCTOR SCHEDULE Salem OR 97223 REF DESCRIP./CONDUCTOR TYPE CONDUCTOR GAUGE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE SYSTEM SIZE 6.82 kW A PV-MARE&BARE GROUND #10/#6 2/1 IN FREE AIR 2 Strings of 11 Modules/Optimizers(SilFab Solar B TMNN-2 #10/#10 4/1 EMT 3/4" 310W/SolarEdge P320) C BARE GROUND #6 1 IN FREE AIR Sheet 1 of 3 D TI-MIN-2 #8/#8 3/1 EMT' 1" Date: November 16, 2017 NOT TO SCALE PORTLAND/HILLSBORO ElevHigh Temp _ Distance above roof Extreme ENERGY 0.4% [2%Avg. 1 0.5" 3.5" 12" Min 62 m 37 °C 32 'C 154`C J 49 'C 46 "C -8 ``: Solutions Correction Temoeratures Voltage Drop calculations; iloomommeme 4Tcob=-8°C-25°C=-33°C 4Thot=(37°C+35°C)-25°C=47°C PV Nominal String Voltage: 380Vdc P.O. Box 887 Flush Roof Mount PV MPPT String Current: 310W x 11 +380V=9.0A Beavercreek, Oregon 97004 DC conductor run is 75 ft(estimated) Phone: 503-680-3718 Module Voltaae Calculations DC Voltage Drop Silfab Solar 310W Mono(SLA-310M) (2 x 75ft x 9.0A x 1.240/kft x 100)/(1000ft/kft x 380V)=0.44% Voc=40.25V Vmp=33.05V Voc Temp Coefficient=-0.30%/°C In=9.93A Imp=9.38A Pmax Temp Coefficient=-0.38%/°C Inverter Output is 240Vac,25A AC conductor run is 15 ft(estimated) Cold Voc=40.25V+(40.25V x-0.30%/°C x-33°C)=40.25V+3.98V=44.2V AC Voltage Drop Hot Vmp=33.05V+(33.05V x-0.38%/°C x 47°C)=33.05V-5.90V=27.1V (2 x 15ft x 25.0A x 0.7780/kft x 100)/(1000ft/kft x 240V)=0.24% SolarEdge P320 Optimizer Max Input DC Power: 320W Max Input DC Voltage: 48V Notes: MPPT Operating Range: 8-48V Max Input In Current: 11A • Ampacity calculations from array to inverter based on 4 current- Maximum DC Output: 15A Min/Max Input String Length: 8/25 carrying conductors in conduit. SolarEdge SE6000H-US Inverter • Interconnection to the main service via a back-fed circuit breaker Max DC Input(V):480V Max DC Input(A): 16.5A in the MSP. Complies with 705.12. Nominal DC Input: 380V Max Power per String: 5700W • Conductor sizing listed is minimum required based on NEC Output voltage: 240Vac Max Output current: 25.0A ampacity calculations for CU conductors. • PV System to be installed and labeled per National Electric Code. String Sizing Specifically: 11 x 310W=3410W -690.4(D) -690.31(B) Label Calculations -690.5(C) -690.35(C)and(F) MPPT DC Current: -690.13(B) -690.5(C) 310W x 22+380V= 17.9A E-limited to 16.5A by the inverter -690.17(E) -705.12(D) • All equipment used UL listed. Conductor Ampacitv.OCPD&Disconnects • Equipment, conductors and conduit as listed or equivalent. Optimizer Output Circuit: • Inverter listed to UL-1741 for grid-interactive use and GFDI 15A x 125%=18.8A(continuous duty) protection. 18.8A+1.00= 18.8A(PV Wire in free air) #12 AWG(rated for 35A into 75°C terminals in free air) #10 AWG selected for compliance with installation instructions 18.8A+0.8+0.76=30.9A(conditions of use-temp and conduit fill) #10 AWG(rated for 35A into 75°C terminals) No fusing required. Only two strings and each lands on dedicated terminals. ELECTRICAL CALCULATIONS DC Disconnect functions integral to inverter. PROJECT REF: Oliver Bleser Inverter Output Circuit: SITE ADDRESS: 12510 SW Summer Crest Dr, 25.0A x 125%=31.3A Salem OR 97223 #8 AWG(rated for 50A into 75°C terminals and required OCPD) SYSTEM SIZE 6:82 kW 35A,240V,2-Pole Back-Fed Circuit Breaker in the MSP Per the AHJ, no AC Disconnect required. Interconnection circuit breaker 2 Strings of 11 Modules/Optimizers(SilFab Solar serves as disconnecting means for the adjacent inverter. 310W/SolarEdge P320) Sheet 2 of 3 Date: November 16, 2017 IRONRIDGE Flush Mount System i ,, . IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashing ,sand is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior p Pre-stamped engineering letters A ,.i structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance F Online software makes it simple to rating of the existing roof. , - create, share, and price projects. UL 2703 Listed System F 20-Year Warranty Entire system and components meetTwice the protection offered by . " , . `- newest effective UL 2703 standard. :'� x i. competitors. og�e,,,.t. .a a..sk.tt:-/...,,2a•..ro ._. ,,'..,, :,.x:,�Yfi,*.`�+.._.f, t-i:ti- .,' a. z u.�«�x':� �:x.,01:). s.4 .3_ �'-1-.4.° *#4, 1 " '''401..',.''�.'� .;�",r zY0. .* 4. d' • XR1O Rail XR100 Rail XR1000 Rail Bonded Splices iri_ .. .......................t..i,ik_ .............,.........„ ..."-:......-LA. A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear& black anod.finish • Clear& black anod. finish • Clear anodized finish • Forms secure bonding UFOs Stopper Sleeves Grounding Lugs Microinverter Kits ., . ... .....„ , _ _ _ .._..,___ L Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled &tubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • 6 different sizes • Single tool installation • Kit comes assembled • Clear& black finish • Clear& black anod. finish • Mounts in any direction • Listed to UL 2703 FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs ' .,...isito 0 -4, --'-': Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to certified attachments. to various heights. • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7"lengths • Mill& black finish • Clear& black anod. finish • Assembled&lubricated • Ships assembled - —0 Design Assistant 7<„,,,,,-; NABCEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems. d`.Y�. t: z, .„p't L .,..bfr- l,, , i ar s.y7,3' .9 ,+ r-,A,"*-,,,,,,-,--,*-- i3 "Iii f`:'drat`”',.t' '�+:-,-, e,..,,t, „ , ,:',„�, fie" , ,,,,,—`.,,77-r","7:+ ," . ; IRONRIDGE FlashFoot 2 3.56 ( ) U tlINA ( 1.02) I (3.67) 1,r 2o T i THIS EDGE TOWARDS ROOF RIDGE Q ( 12.00 ' , i CD- I = (3.00) I Y --"1--( 4.50 ( 9.00) NO. PART NUMBER DESCRIPTION QTY. 1 FM-100-006 ASSY, FLASHING, MILL 1 2 FM-100-008 ASSY, CAP, MILL 1 SCREW, LAG, HEX, 5/16. W/ 3 23-3118-475LGF CUSTOM HEAD, 7/16 HEX W/ 1 KIT, FLASHFOOT 2 FLANGE 4.75E slzE 4 25-3102-000S WASHER, EPDM BACKED A DO OansaNOT LE DRAWING 1 S AI F:1'4 W(I aHT'OaR HIS VIfFI l(IF 1 *Bill of materials shown is for a single FlashFoot 2 assembly. 0 2018 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information. FM-FF2-MAN REV 1.0 Installation Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun, driver with 1/4" bit and 7/16" hex socket. I I, l I 1 % i 3rd course , 1 i' , , i l l Rafter 1 i t 3rd course I I i I I ' I l l I1 , , l r l 1 1 7 I I d se' . . . _ � i2n tour I I r I 9 I I' --- __. 1St course , Locate rafters and snap vertical and horizontal lines Slide flashing, between 1st and 2nd course, so the to mark flashing locations. Drill 1/4" pilot holes, then top is at least 3/4" above the edge of the 3rd course fill with roofing manufacturer's approved sealant. and the bottom is above the edge of the 1st course. ii ' i Line up pilot hole with flashing hole and insert lag Place Cap onto flashing in desired orientation for bolt with bonded washer through flashing. Tighten E/W or N/S rails and rotate 180 degrees. Flash Foot lag bolt until fully seated. 2 is now installed and ready for IronRidge XR Rails. Structural Certification Designed and Certified for Compliance with the International Building Code&ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27"Rain Test"and TAS 100-95"Wind Driven Rain Test"by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See IronRidge Flush Mount Installation Manual for full ratings. Attach rails to either side of the open slot using bonding hardware. Level rail at desired height, then torque to 250 in-lbs (21 ft-lbs). 0 2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information. FM-FF2-MAN REV 1.0 .... ......„.....,„‘, ,.......,......:,.,,,„:„.„ . ......,...„„„,,„„, SLAM .. , :„ ...., ,,,,Si it ,, ..,,, ,D ,, ,...„ N'''''" :- Monocrystalline .. .. SOLAR s -'-",-,;,,,,,--t;.'•,: ,-,,,,k, ,,,,,:---- BAA, 2'15 , 1.- JUST-IN- niiiis TIER IJ III V BANKABLE ' - • - s --""'""-"' ------ TESTED $$$ 10 0 HIGH VOLTS EFROVICT "MPIN...L_II ,/irr 100% MAXIMUM POWER DENSITY ' 3 Silfab's SLA-M 310 ultra-high-efficiency modules are optimized for both Residential and Commercial projects where maximum ' 09/. c 1 1 power density is preferred. e 10 . I a NORTH AMERICAN ' QUALITY MATTERS Silfab's fully-automated manufacturing facility onacrystaifirle mensures precision engineering is applied at every stage.Superior reliability and performance combine to produce one of the highest PV Nit)dtile - quality modules with the lowest defect rate in the industry. NORTH AMERICAN CUSTOMIZED SERVICE Silfab's 100%North American based team leverages just-in-time manufacturing to deliver •CE IEC Ej ("114) .0,111Fraunkt f,-......,....1. unparalleled service,on-time delivery and flexible project solutions. ENSURES MAXIMUM EFFICIENCY44 PPM DEFECT RATE* . 60 of the highest efficiency,premium quality monocrystalline Total automation ensures strict quality control during each cells result in a maximum power rating of 310VVp. step of the process at our certified ISO manufacturing facility. *Asof December 31,2016 ADVANCED PERFORMANCE WARRANTY 25-year linear power performance guarantee to 82% LIGHT AND DURABLE Over-engineered to weather low load bearing structures up ENHANCED PRODUCT WARRANTY to5400 Pa.Light-weight frame exclusively designed with 12-year product/workmanship warranty wide-ranging racking compatibility and durability. BUILT BY INDUSTRY EXPERTS PIDRESISTANT With over 35 years of industry experience,Silfab's technical Proven in accordance to IEC 62804-1 .............. team are pioneers in PV technology and.are dedicated to an .... innovative approach that provides superior manufacturing AVAILABLE IN ...... osNDE:t4;-....... processes including:infra-red.cell sorting,glass washing, All Black : ( .4,,....;:...„...., ,..... automated soldering and meticulous cell alignment. . i ,,,4, .....,:.... li Russell Pacific ... POSITIVE TOLERANCE , (-01+5W)All positive module sorting ensures % •Pi. iSL .- maximum performance Proud Partner .,,..........., Electrical S•,ecifications <:St MB$Mon0c nine,.:` ',_ x Test Conditions STC NOCT Module Power(Pmax) Wp 310 234 Maximum power voltage(Vpmax) V 33.05 29.7 Maximum power current(Ipmax) A 9.38 7.88 Open circuit voltage(Voc) V 40.25 37.2 Short circuit current(Isc) A 9.93 8.14 Module efficiency % 19.0 17.9 Maximum system voltage(VDC) V 1000 Series fuse rating A 15 Power Tolerance WP -0/+5 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25°C•NOCT 800 W/m •AM 1.5•Measurement uncertainty 5 3% •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics mayvary by±5%and power by-0/+SW. Tern. ature'Ratln: 1^ta e : to -e t:,,v-I'' -..-i;,.;:,:i.,,,,,,, 4 -1,-;.,:',.....,, ,f. Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.38 NOCT(t 2°C) °C 45 Operating temperature °C -40/+85 Mechanical Pro.erties and Corna onenits `4' -;- •'- ' .° :-.`2`SiMo . ry l '`' Module weight(±1 kg) kg 19 Dimensions(H x L x D;±1mm) mm 1650 x 990 x 38 Maximum surface load(wind/snow)* N/m2 5400 Hail impact resistance 0 25 mm at 83 km/h Cells 60-Si monocrystalline-3 or 4 busbar-156.75 x 156.75 mm Glass 3.2 mm high transmittance,tempered,antireflective coating Backsheet Multilayer polyester-based Frame Anodized Al Bypass diodes 3 diodes-45V/12A,1P67/1P68 Cables and connectors(See installation manual) 1200 mm a 5.7 mm(4 mm2),MC4 compatible Warranties Module product warranty 12 years 25 years >_97%end of 1st year Linear power performance guarantee z 90%end of 12th year >_82%end of 2515 year CertificationsStl. AA,Mame : Product ULC ORD C1703,UL 1703,IEC 61215,IEC 61730,IEC 61701,CEC listed 4 UL Fire Rating:Type 2(Type 1 on request) Factory ISO 9001:2008 ',,= A Warning:Read the installation and User Manual before { \ handling,installing and operating modules. Drain,,: .g 38 Grountli Third-party generated pan files from PV Evolution Labs available Hole E for download at:www.silfab.ca/downloads e = ° ;r Pallet Count:up to 25 per palletunci >a 'i Mounting Slot . ° 2::Container Count:900 ii� 11 i' j a i m ei El ..c Profile View c II 0 sr LAP ° 04.2.2 Grounding 11 ANgmenelonsinmm i dn Hot, Tolerances timer Z Silfab Solar Inc. Naetolerances:tosmm Drawings not toscale 240 Courtneypark Drive East•Mississauga,Ontario Canada L5T 2S5 Tel+1 905-255-2501 •Fax+1 905-696-0267 1 ggg I ^, info@silfab.ca•www.silfab.ca j c/) solar - • • oc W SolarEdge Single Phase Inverters F-- for North America W SE3000H-US / SE3800H-US / SE5000H-US/ SE6000H-US/ SE7600H-US `pverfe, 12'26 5 ve* Wa '° av •••• • _ S • • Optimized installation with HD-Wave technology is Specifically designed to work with power optimizers mr Record-breaking efficiency fig Integrated Arc Fault protection and Rapid Shutdown for NEC 2017,690.11 and 690.12 off Extremely small Pp 4pr wa R 3P • High reliability without any electrolytic capacitors Built-in module-level monitoring wave • Outdoor and indoor installation Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) • kw!, ti r f : ;,C t _F'.Pe .iaa;,9. �, Ft':I.I �HF Pii` / F..±t td KF{ ,(0)IH if IN!(r,I I 1 1;5 A`ww.soiar IE�f .us solarSingle Phase Inverters for North America SE3000H-US I SE3800H-US I SE5000H-US I SE6000H-US/SE7600H-US .. .............................. . SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA Max.AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min.-Nom.-Max.(183-208-229) V Vac AC Output Voltage Min.-Nom.-Max.(211-240-264) ✓ ✓ ✓ ✓ ✓ Vac AC Frequency(Nominal) 59.3-60-60.5"I Hz Maximum Continuous Output Current 208V - - 24 - - A Maximum Continuous Output Current 240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V 15.5 Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ku Sensitivity Maximum Inverter Efficiency 99 99.2 oi CEC Weighted Efficiency 99 % Nighttime Power Consumption <2.5 W .......... ADDITIONAL FEATURES Supported Communication Interfaces R5485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional'z' Rapid Shutdown-NEC 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL16996,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 211'1,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 0.75-1" Conduit/14-6 AWG DC Input Conduit Size/#of Strings/AWG Range 0.75-1" Conduit/1-2 strings/14-6 AWG Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm Weight with Safety Switch 25.3/11.5 lb/kg Noise <25 d8A Cooling Natural Convection Operating Temperature Range -13 to+140/-25 to+60m(-40°F/-40°C option)rs' 'F/°C Protection Rating NEMA 3R(Inverter with Safety Switch) ,r'For other regional settings please contact SolarEdge support 'Z'Revenue grade inverter P/N:SExxxxH-US000NNC2 `''Pending certification ''Power de-rating from 50'C •'''-40 version P/N:SErxaxH-US000NNU4 (II cs ec. RoHS 55 SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies.Inc.All other trademarks mentioned herein arc trademarks of their respective owners.Date:02/2017 V.01.Subject to change without notice. solar - • • rir W SolarEdge Power Optimizer _ Module Add-On For North America P300 / P320 / P400 / P405 �- 0 oc w 1251¢ $Waw =r�' PV power optimization at the module-level • Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ▪ Flexible system design for maximum space utilization • Fast installation with a single bolt — Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety USIA - RMANY VOLLY SE N( JASAN - C-HINA AUSTRALIA WWW.solaredge.us SolarEdge Power SO�c�r • • �- Optimizer g Module Add-On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 (for 60-cell modules) (for high-power (for 72&96-cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Powero) 300 320 400 405 W Absolute Maximum Input Voltage 48 80 125 Vdc ()Mc at lowest temperature) MPPT Operating Range r 8-48 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 ! 11 10 Adc Maximum DC Input Current 12.5 13.75 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters 128 x 152 x 27.5/ 128x152x35/ 128x152x48/ Dimensions(W x L x H) 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 mm/in Weight(including cables) 770/1.7 930/2.05 930/2.05 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated;MC4 Compatible Output Wire Length 0.95/3.0 1.2/3.9 m J ft Operating Temperature Range -40-+85/-40-+185 . °Cf`F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % ,'I Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(Z( Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes or Orientations ,ti It is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE 0 ©SolarEdge Technologies.Inc.All rights reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies.Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2015 V.01.Subject to change without notice.