Loading...
Report (2) /4 S T)-0/7tit ( FIVF G� Z LTC NOV 8 2017 10372 SW Bonanza Way Tigard, OR 97224 LAUREN THOMAS °t: 11GA1) 503-317-1023 CONSULTING,LLC BUILDING DiVISiON LTCstructural@gmail.com Gerhard Dormer Addition 14275 SW 125th Tigard, Oregon Client: Garza Construction LTC#: 17-55ADS Date: 11/1/17 By: Lauren Thomas, P.E. r M fF, Vit: yf r;4 No. of Calculation pages included: R8 pages Engineer has been retained in a limited capacity for this project. The design of this project is based upon information provided by the Client who is solely responsible for the accuracy. No responsibility and/or liability is assumed by, or is to be assigned to the Engineer for items beyond that indicated on these sheets. C. ( ° ) (4-4-- rb) rer. 4 C 1 •"--;\. r ..)c--t. :7 .„...._ ,.„ 0 c G., , 67:1', 2 :74) 3 , —3 '2, ,.... \ -- c <--- s, ' tf ,-.7.,, --_) )( -). -- , C \ c,„ - , trt c____Q i ,----------- -'--- -- = \u-2- -,-_,_ \ Cp(-1-7 ---- ,3 ' 1 ' ' f ::)- 1: A ----- ‘17;) \' ' C--) •- ," L__z 7' c/0 z R- O ? .._.„ . 4? 1 ,--51:-, f' 7- 4- SOO Lf (.., 55 t 44 V \\ (q ICt fa) ,.....,..___ Project Name Gerhard Dormer Addition/Front Porch Project# 17-55ADS LTC Location 14275 SW 125th, Tigard, Oregon LAUREN THOMAS CONSULTING LIC Client Garza Construction 10372 SW Bonanza IN ay Tigard,OR 97224 503-3174023 LIcstructural(a gmail com By LMT Date 10/31/17 Page ( ,. of , • FL t..-„ck,17 (--,-;"-e(2.--C.0 :- (15 .4- .\. (2-) ,---)( ' --; ?-'0 VT.- .----L------. ___. .- ____.._...._._ r , _ , z 7: -_-_ L43,4) \C F- ,1-\,) •7--, vs-Lt.: ,--- ' .---- ,,t. ) ,i ,,--) (46)(4 a \ ceOP'-'4(-- CL._ V' YY\ - L ' 0\ r1 L..) 27 if f t , 1 cy,,,y,\M. \ ) „,, f i 4 7, • ------ ..-- -- ! 1 ttlaProject Name Gerhard Dormer Addition/Front Porch Project# 17-55ADS C Location 14275 SW 125th, Tigard, Oregon LAUREN THOMAS CONSULTM LIC Client Garza Construction 10372 SW Bonanza Way Tigard,OR 97224 Ltrstr:13:03.alg°m23ail.com By LMT Date 10/31/17 Page c7,16,. of r(z..., 2 tz} A- I4 i ( V) 3 Ai 7..... 5th- 43(6._72+,� G t2.2�`� i\Aror-s. A (---3—,m) ( l -') 4 1,(p(40 (g) ' -4- a4 �( 4- C dol( 10)( t V ) ,G Z (a )( 1 )( 4Ct®1(_� ,2t2 , A-2 z ( /3 ( /t5 - 3 , ( /44-7,6-41 v 0\(1 ,2`JCki4-7u•-( 0,4.3 0 c - :>:_)--fiz_L,.0 Li") i-DD.e tom, n ' 1-Kari Sf S t/4 ?VIA PH A. tel. k.)(4--0 S F '� .-rig- !,(2_ ..S. 'i'M z• 34-7 i\r34-o -;_S 0 0 r- c- 4 , -( (&) -e- 3`*°. -"1:-.7 Ha-2 ( q) (/0)(M)2--h 4- ( /0)(4i1) ( / )")2-1 4. ((0)(9)(i0)(1 z..... 2_,s- 141.1- 2* 3e, - 2-1 (2 / , z 440z. 1, Project Name Gerhard Dormer Addition Project# 17-55 LTC I Location 14275 SW 125`}', Tigard, Oregon LAUREN THa,As c°tom t,t�°LL� Client Garza Construction 10372 SN'Borenr�N'ay Tigard,OR 97224 503.327.1023 igy LMT Date 6/12/17 Page of i() Ltcstructural gmaiLcom A loi . , if,_ cu-,3 avit-t SIMPSON Anchor Designer TM Company: Date: 11/1/2017 Engineer: Page: 1/4 Strong-Tie $O Project: Versionon 2 2.3..5555.372 Address: Phone: E-mail: 1.Proiect information Customer company: Project description:LTC 17-55 Customer contact name: Location:Tigard,Oregon Customer e-mail: Fastening description: Comment: 2,Input Data&Anchor Parameters General Base Material Design method:ACI 318-11 Concrete:Normal-weight Units:Imperial units Concrete thickness,h(inch):6.00 State:Cracked Anchor Information: Compressive strength,fc(psi):3000 Anchor type:Concrete screw LP.,v: 1.0 Material:Carbon Steel Reinforcement condition: B tension,B shear Diameter(inch):0.500 Supplemental reinforcement:Not applicable Nominal Embedment depth(inch):3.750 Do not evaluate concrete breakout in tension:No Effective Embedment depth,her(inch):2.780 Do not evaluate concrete breakout in shear: No Code report:ICC-ES ESR-2713 Ignore 6do requirement:Not applicable Anchor category:1 Build-up grout pad:No Anchor ductility:No h..(inch):5.83 Base Plate cec(inch):4.19 Length x Width x Thickness(inch):2.00 x 10.00 x 0.25 Cmc(inch):1.75 Smin(inch):3.00 Load and Geometry Load factor source:ACI 318 Section 9.2 Load combination:not set Seismic design:Yes Anchors subjected to sustained tension:Not applicable Ductility section for tension:D.3.3.4.3(a)3-6 is satisfied Ductility section for shear:D.3.3.5.3(a)is satisfied Qo factor:not set Apply entire shear load at front row:Yes Anchors only resisting wind and/or seismic loads:Yes <Figure 1> ZO Ib 1500 II Oft-Ib 4 ...t4r Oft-Ib Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company nc 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com J company: SIMPSON Anchor DesignerTM Date: 11/1/2017 Page: 2/4 Engineer: Strong-Tie Software Project: 1,-P‘Aws-sai-a.."'" Version 2.3.5555.372 Address: Phone: E-mail: <Figure 2> 8 8.00 (.1 48.00 6.00 Recommended Anchor Anchor Name:Titen HD®-1/20 Titen HD,hnom:3.75"(95mm) Code Report Listing:ICC-ES ESR-2713 - _ Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company'nc 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: Date: 11/1/2017 Engineer: Page: 3/4 Software Project: St>t'Orig-Tie Version 2.3.5555.372 Address: Phone: E-mail: 3.Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nue(lb) Vuax(lb) Vuay(Pb) J(Vuex)2+(Vuay)2(Pb) 1 0.0 0.0 750.0 750.0 2 0.0 0.0 750.0 750.0 Sum 0.0 0.0 1500.0 1500.0 Maximum concrete compression strain(%o):0.00 <Figure 3> Maximum concrete compression stress(psi):0 Resultant tension force(Pb):0 Resultant compression force(Ib):0 Eccentricity of resultant tension forces in x-axis,e'Nx(inch):0.00 Eccentricity of resultant tension forces in y-axis,e'Ny(inch):0.00 Eccentricity of resultant shear forces in x-axis,e'vx(inch):0.00 01 X 02 Eccentricity of resultant shear forces in y-axis,e'vy(inch):0.00 8.Steel Strength of Anchor in Shear(Sec.D.6.1) Vsa(lb) fgrouw g} qlgrout0Vsa(Ib) 4790 1.0 0.60 2874 9.Concrete Breakout Strength of Anchor in Shear(Sec.D.6.2) Shear perpendicular to edge in y-direction: Vby=minI7(la/da)°'2Jda.i..Jfocal15;9.1eJfccal1 5f(Eq.D-33&Eq.D-34) le(in) da(in) A.. fo(psi) cal(in) Vby(Ib) 2.78 0.50 1.00 3000 6.00 5615 0Vcby=0(Avc/Avco)'Fed v 'v'Ph.VVby(Sec.D.4.1 &Eq.D-30) Avo(in2) Avoo(in2) Ted Y'c.v Y'h v Vby(lb) 0 0Voby(lb) 66.00 162.00 0.767 1.000 1.225 5615 0.70 1504 Shear parallel to edge in y-direction: Vbx=minI7(le/da)02JdaAaJfcco115;9.1. fcca/1.5I(Eq.D-33&Eq.D-34) /e(in) de(in) A. f'0(psi) col(in) Vb.(Pb) 2.78 0.50 1.00 3000 2.00 1081 glVcbgy=1b(2)(Avc/Avoo)f'ec,vY'ed,vy'c,vy'h,vVbx(Sec. D.4.1 &Eq. D-31) Avc(in2) Avco(in2) geov Ted N'o,v Y'h,v Vbx(Pb) 0 glVobgy(Pb) 36.00 18.00 1.000 1.000 1.000 1.000 1081 0.70 3026 10.Concrete Pryout Strength of Anchor in Shear(Sec.0.6.3) OVcpg=OkcpNcbg=Okcp(ANc/ANco)PecN yed,N P,N 17 opNNb(Eq.0-41) kg, ANC(in2) ANco(in2) gecN ged,N `'o,N yop,N Nb(Ib) 0 Øl/pg(lb) 2.0 100.82 69.56 1.000 0.844 1.000 1.000 4316 0.70 7391 11.Results Jnteraction of Tensile and Shear Forces(Sec.D.7) Shear Factored Load,V..(Ib) Design Strength,eV, (lb) Ratio Status Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company nc 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com [�t Vr if m SIMPSON Anchor Designer TM Company: Date: 11/1/2017 Engineer: Page: 4/4 Strong-Tie• Software Project: Version 2.3.5555.372 Address: Phone: E-mail: Steel 750 2874 0.26 Pass T Concrete breakout y+ 1500 1504 1.00 Pass(Governs) Concrete breakout x+ 1500 3026 0.50 Pass(Governs) Pryout 1500 7391 0.20 Pass 112"0 Titen HD,hnom:3.75"(95mm)meets the selected design criteria. 12.Warnings -Per designer input,ductility requirements for shear have been determined to be satisfied—designer to verify. -Designer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company'nc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com / F ' jT I ( € - d if ``l ciy -- 0Alwe < < _ COi ` Y U ' .f6 `L , -4 (- 1. ____ 4- 1 I I( k 4,-1 ) (,4) ( (4) -t- U acv( -� t. 0 (4 o) ` 534 Si- -e7,0 6,,k-00--D(....__0,--- ------ z , (-)-2,:) ___:: L__)--2. 0,,, .,-.ccV0 o _ Project Name Gerhard Dormer Addition/ Front Porch Project # 17-55ADS LTC Location 14275 SW 125`h, Tigard, Oregon LAUREN TNOMac CONSULTNL.LLC Client Garza Construction 10372 SW Bonanza Way Tigard,OR 97224 n � 503.3174023 BY LMT Date 10/31/17 Page of \��-' Lltslructunlld gmaiLcom J