Plans
OFFIcE COPY ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. A NATIONALLY-RECOGNIZED TESTING . CONC CONCRETE LABORATORY SHALL LIST ALL EQUIPMENT IN DC DIRECT CURRENT COMPLIANCE WITH ART. 110.3. EGC EQUIPMENT GROUNDING CONDUCTOR 3. WHERE ALL TERMINALS OF THE DISCONNECTING (E) EXISTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, EMT ELECTRICAL METALLIC TUBING A SIGN WILL BE PROVIDED WARNING OF THE OC 201 7 FSB FIRE SET-BACK HAZARDS PER ART. 690.17. GALV GALVANIZED 4. EACH UNGROUNDED CONDUCTOR OF THE CITF GEC GROUNDING ELECTRODE CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY BUILDING 1 /SION GND GROUND PHASE AND SYSTEM PER ART. 210.5. HDG HOT DIPPED GALVANIZED 5. CIRCUITS OVER 250V TO GROUND SHALL I CURRENT COMPLY WITH ART. 250.97, 250.92(B). Imp CURRENT AT MAX POWER 6. DC CONDUCTORS EITHER DO NOT ENTER OFFICE COPY Isc SHORT CIRCUIT CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kVA KILOVOLT AMPERE ENCLOSURES TO THE FIRST ACCESSIBLE DC CITY OF TIGARD kW KILOWATT DISCONNECTING MEANS PER ART. 690.31(E). REVIE D FOR CODE COMPLIANCE LBW LOAD BEARING WALL 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN MIN MINIMUM RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY Approved: (N) NEW UL LISTING. OTC: NEUT NEUTRAL 8. MODULE FRAMES SHALL BE GROUNDED AT THE NTS NOT TO SCALE UL-LISTED LOCATION PROVIDED BY THE Permit#: r c -4-„ ,-1)-7-cab(4,4_4- OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING Address: P1.�a.Er .5 w Amt AVG. L PROPERTY LINE HARDWARE. P01 POINT OF INTERCONNECTION 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE Suite #: PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS. $y; Date: SCH SCHEDULE �� in-z;1- 1-7 S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT � Sheet 1 COVER SHEET 'Iv; ' e �_ Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS LICENSE GENERAL NOTES �� � ,� Sheet 4 UPLIFT CALCULATIONS - � Sheet 5 THREE LINE DIAGRAM Sheet 6 ELECTRICAL CALCULATIONS OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC � Cutsheets Attached RGC, CGC1 AND 2012 IBC. t 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRIC CODE ASfar . AMENDED BY THE OREGON ELECTRICAL SPECIALTY �� CODE. MODULE GROUNDING METHOD: ZEP SOLAR ' � ` AHJ: Tigard _ o° REV BY DATE COMMENTS 121:11113:11 DATE COMMENTS UTILITY: Portland General Electric .. ©©© CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER JB-9723845 0 0 PREMISE OWNER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE KEVIN CR A WFOR D _ BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: Kevin Crawford RESIDENCE Derrick Olds T S L �I SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13265 SW ASH AVE 5.1 KW PV ARRAY n PART TO OTHERS OUTSIDE THE RECIPIENTS TIGARD, OR 97223 -= THE SALE AND EXCEPTES THIN E CONNECTION (M 17)sTRINA SOLAR # TSM-300DDO5A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: PERMISSION OF TESLA INC. INVfR7ER: SHEET: REV: DATE Delta ; Solivia 5.2 TL COVER SHEET 1 10/13/2017 i \ .,-,,, ✓ ` MP1 PITCH: 25 ARRAY PITCH:25 f 0 AZIMUTH: 130 ARRAY AZIMUTH: 130 :. MATERIAL: Comp ShingleSTORY: 1 Story f =; i �� 11 . -. ;4 _ v 4 1 L�keq QiatC'C� ° ° I. �\ AA,, i X ' t` ,., f=\� r rte',4: �.F - l , ,,,. '2 "'-- 1 i E3; j,,.. i s� '- N it / f N a . � LEGEND 4�7? ., Front Of House 10 (E) UTILITY METER & WARNING LABEL I®I INVERTER W INTEGRATED DC DISCO & WARNING LABELS RELAY AUTOMATIC RELAY Ac I-4-1 AC DISCONNECT & WARNING LABELS ENERGY STORAGE SYSTEM FOR STAND —1 0 o r--„-4„, ® ALONE OPERATION D %� LESS; _ I@I DISTRIBUTION PANEL & LABELS ?00 ° 0 F-_,, Lc LOAD CENTER & WARNING LABELS a (E)DRIVEWAY A DEDICATED PV SYSTEM METER 0 0) RSD RAPID SHUTDOWN IIISTANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR RSD Gisiaa CONDUIT RUN ON INTERIOR GATE/FENCE ® Lc AC II RELAY o HEAT PRODUCING VENTS ARE RED H'•-1 O -1--- i-------:,7,,,, r,, ' '' INTERIOR EQUIPMENT IS DASHED 0 x . PLAN f f, SITE t. Y ' '� r s TOTAL ARRAY AREA (SF): 306 TOTAL ROOF AREA (SF): 2258 /32" = 1'a �A Scale: 3 '` 7" ' ,,,,,,„1, --1I-----,,„1,i AREA IS O 1' 10' `� TOTAL ARRAY a 13.54 21' _ CONTAINED L A THE INFORMATION HEREIN ::: ER: B-�7238�l � PERCENT QF TOTAL RQQF AREA v`Y0 PREMISE OER: -FOR mpSYSTEM: KEVIN CRAWFORD DESCRIPTION: SHALL IT BE DISCLOSED IN WHOLE OR IN Kevin Crawford RESIDENCE DESIGN: _ _ PART ORGANIZATION, OTHERS OUTSIDE THE CONNECTION WITH Comp Mount Type C 13265 SW ASH AVE Derrick Olds THE SALE AND USE OF INITHE RESPECTIVE�TM M 17) TIGARD, OR 97223 5.1 KW PV ARRAY = 5 L n TESLA EQUIPMENT, WITHOUT THE WRITTEN (17) TRINA SOLAR # TSM-300DD05A.18(II) PAGE NAME: PERMISSION OF TESLA INC. INVERTER: Delta # Solivia 5.2 TL SHEET: REV: DATE: SITE PLAN 2 10/13/2017 (E) 2x4 0 .\111. 1 \ PRE-MANUFACTURED TRUSS STRUCTURE MEETS THE } PRESCRIPTIVE REQUIREMENTS 4",001 2" 7'_9" / 6'-1" / OF THE OSSC SECTION 3111 f (E) LBW A SIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 39" 0" STAGGERED PORTRAIT 48" 20" 64" 0" TOP CHORD 2x4 @ 24"OC ROOF AZI 130 PITCH 25 ARRAY AZI 130 PITCH 25 STORIES: 1 BOT CHORD 2x4 @24"OC Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16" BOLT WITH I INSTALLATION ORDER I FENDER WASHERS ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. SEAL PILOT HOLE WITH ZEP COMP MOUNT C — (4) POLYURETHANE SEALANT. J __. �_'� ZEP FLASHING C �� ' J ,� �_��� ��S (3) INSERT FLASHING. (E) COMP. SHINGLE PLACE MOUNT. (E) ROOF DECKINGMEI J 5/16" DIA STAINLESS (5) (5)I INSTALL LAG BOLT WITH I STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES SEALING WASHER. WITH SEALING WASHER (6)I INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) BOLT & WASHERS. (E) RAFTER 0 STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL- THE INFORMATION HEREIN rNUMB ER: JB-9723845 OO PREMISE OMMER: CONTAINED SHALL NOT BE USED FOR THE DESCRIPTION: DESIGN: BENEFIT OF ANYONE EXCEPT TESLA INC., NORNTING SYSTEM: KEVIN CRAWFORD Kevin Crawford RESIDENCE Derrick Olds .� SHALL TOIT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13265 SW ASH AVE T 5 L n PART CRGANIZ OTHERS OUTSIDE THE RECIPIENTS 5.1 K W P V ARRAY THE SALE AND EUSE XCEPT IN OF THE CONNECTION ULE& A SOLAR # TSM-300DD05A.18(II) TIGARD, OR 97223TESLA EQUIPMENT, WITHOUT THE WRITTENPERMISSION OF TESLA INC. RTER: lta # Bolivia 5.2 TL PAGE NAME: SHEET: REN. DATE STRUCTURAL VIEWS 3 10/13/2017 10.13.2017 DESIGN SUMMARY 9 Job#Version 3845 Jab#9723845 Design • -1> Importer-actor ASCE - Ultimate Wind Speed 1 '�fl: V Utt 95 mph - Exposure Category Fig.t 1806. Ground Snow Loadpg 2 p �CEtTale 17 25.0 psf ASCE Table 7-1 MP Name MP4 ' 9ETtt81 e Standoff Comp orn• f , awi SL/RLL:PV 25.0• f SL/ :Notr.P r ,. --- MP Name MP1 Ca 72" X-Cantltever 24" Y rn ' � Y.Ca�ifever � NA X-CCantilever 20• o S4 Y-Cantilever NA X and Y are maximums that are alwa s relative to the structure framin that su.sorts the PV. Xis across rafters anti Y is alone rafters. CONTAINED ALA THE INFORMATION HEREIN NUMBER: g_g 723845 00 CONTAINED SHALL NOT BE USED FOR THE PREMISE OWNER: BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: KEVIN CRAWFORD DESCRIPTION: SHALL IT BE DISCLOSED IN WHOLE OR IN Kevin Crawford RESIDENCE DESIGN: PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C 13265 SW ASH AVE Derrick Olds ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES, 5.1 K W P V ARRAY T ` L. r"1 THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-300DD05A.18(II) TIGARD, OR 97223 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. INVERTER: Delta # Solivia 5.2 TL PAGE NAME UPLIFT CALCULATIONS SHAT: REV 4 1 100/13/2017 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES BOND (N) #8 GEC TO ONE (E) GROUND Panel Number:BR2040B200 INVERTER SPECS MODULE SPECS ROD AND ONE (N) GROUND ROD AT Meter Number:24550832 Inv 1: DC Ungrounded INV 1 -(1)Delta # Solivia 5.2 7L ABEL: AAR �!1 (( LICENSE PANEL WITH IRREVERSIBLE CRIMP Underground Service Entrance Inverter;5200W, 240V/208V, 97.5%/97.5%, Zigbee, PLC -(17)PV MoRINA dule 300W,270.6W PTC,40MM,Blk Frame,MC4,ZEP,1000V,Wht BckSht ORGC,18GC1 18 INV 2 INV 3 Voc: 39.9 Vpmax: 32.6 E 200A MAIN SERVICE PANEL Ise AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E) 200A/2P MAIN CIRCUIT BREAKER (N) 125A BRYANT (E) WRING LOAD CENTER Inverter 1 IND Delta AUTOMATIC RELAY DD CUTLER-HAMMER Ol Z I Disconnect ® y (. Delta I A I A 200A 2P Solivia 5.2 TL -+� DC+ i /\ / � A �• n 125A/2P 30A 2P �� Dc- I MP1: 1x9 - --. I 240V I r 1 . \. • -• -• •- n L11- J EGC J N L2 •� Dc+ E-Gf-E� -- ------- GND _�_ N DC- II- El -L-► I ?DC+ I T l © 0r- T EGC/ I •� DC+ �� \J GEC '1 �_ DG -"�L N�--- LJ G 4� MPl: 1x8 EGG! N L2 L1 GEC I 1 GND I-___EGC_ - ____�- .GC -L- I 30 2P DD L1 _T r �LJ J, Z I il • 1.121] Z X I JENERGY STORAGE V _- i 1.,,, ____ E<c SYSTEM OAS 2002P i i � 00 L1 i- i ' ry X ENERGY STORAGE TO 120/240v SYSTEM -• •- SINGLE PHASEI I L__ EGC _.,--,... i. UTILITY SERVICE I II --• • I I (E) LOADS I I I I I I I i I (E) 200A Main Service Panel Voc* = MAX VOC AT MIN TEMP POI-(1)Groygd Roc 5 8 x 8, Copper X -(2)Tesla 109217D-03-D-ST ZAC P WERWALL 5.8kVA; Home Energy Storage,13.5KWH - Rev C, Stackcil �W2,0 -'(2)Delta #Solivia -(1)Tesla 1118431-00-G " Smart RSS Rapid Shutdown, 600V, 20A NEMA 4X, MC4 DC BACKUP GATEWAY; for ACPW2.0, ASY, NA with 3G w/Antenna, PW2.0, 10kAIC T -(2)CUTLER-HAMMER #BR230 -(1)Siemens!E08695, BK200A Breaker; 30A/2P, 2 Spaces I Circuit Breaker MBK200A/ 2P, 22kAIC [ -(1)CUTLER-HAMME2 , BR230 B (1)Cutler-Hammer/DG224URK Breaker; 30A 2P, 2 Spaces General Duty Disconnect, 200A, 240Vac, Non-Fusible, NEMA 3R -(1)BRYANT/BR81P -(1)CUTLER-HAMMER!DG200NK Load Center; 125A25A,, 120/240V, NEMA 3R Ground/Neutral it; 200A General, Heavy Duty(DG, OH), NEMA 1, 3R -(1)CUTLER-HAMMER I BR2125 Breaker; 125A/2P, 2 Spaces _m_m__ -(3-)AWG#3/0, THWN-2, Black.._ __ _._._.,._ _ MANG_ - �6, THWN-2, Green EGC/GEC B (1)AWG 3 it(1)AWG#10, THWN-2, Red k (1)Conduit Kit 2"EMT 1 I� ( (2)AWG X10, PV Wire, 600V, Black Voc* =398.67 VDC Isc =9.64 ADC (3)AWG/2/0, THWN-2, Black (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21.6 MC 1 v (1)Con #10, THHN/T 600V, Green -(1 AWGOEGC Vmp =293.4 VDC Imp=9.19 ADC ® (1)AWG . THWN-Z, GREEN EGC/GEC 1) #6..THWN-2, Green EGC GEC- 1 Conduit Kit; 3/47 EMT I (1 Conduit Kit; 3/4" EMT . . . . . . . . . . . . . . . . . . . . Cu, Stranded; 1 _ (1)AWG y2, THWN-2, Black /'' ' ' ' ' ' ' =354.38 VDC Isc=9.64 ADC -(1(I)Conduit Kit; 1-1/2" EMT ®� f (1)AWG X12, THWN-2, Red (2 AWG 10, PV Hire, 600V, Black Voc* O (1)AWG#10, 7HHN/THWN-2, Green EGC Vmp =260.8 VDC Imp=9.19 ADC (1)AWG #2, THWN-2, White NEUTRAL (1)Conduit Kit; 3/4` EMT (1)AWG#10, THWN-2, Black -(1)AWG#6, THWN-2, Green EGC/GEC-(1)Conduit Kit; 1-1/4"EMT el g-(1)AWG#10, THWN-2, Red (1)AWG#10, THWN-2, White NEUTRAL -(1)CONDUIT KIT - -(1)AWG 110. THWN-2. Green E 1 x 10'EMT Conduit CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9723845 00 PREMISE OWNER: I CONTAINED SHALL NOT BE USED FOR THEDESCRIPTION: BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: KEVIN CRAWFORD DESIGN: SHALL TOIT OBE DISCLOSED OUTSIDEIN WHOLE OR IN CompMount T 13265 SW ASH AVE Kevin Crawford RESIDENCE Derrick Olds �, PART ORGANIZATION, OTHERSEXCEPT TTHEORECIPIENTS �e 5.1 KW PV ARRAY _. 5 L n THE SALE AND USE OF INTHE CONNECTION (17)STRINA SOLAR # TSM-300DDO5A.18(II) TIGARD, OR 97223 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. INVERTER: Delta # Solivia 5.2 TL PAGE NAME: SHEET: REV: DATE: THREE LINE DIAGRAM 5 10/13/2017 ELECTRICAL CALCULATIONS Module: 17 Trina:TSM 300DD05A.18(II) 270.6 Inv Power WPTC Inverter 1: 1 Delta Solivia 5.2 TL 0.98 5200 4485.2 Voltage Drop Calculations Version 5_8.0 Module: Trina:TSM 300DD05A.18(II) 270.6 Vdrop= Imp) (2 Length)*(Resistance) / Vmp) Imp(A) Max.Length(ft) Wire Inverter 2: String: 9.19 75 AWG#10 at Max Ave Hi:87 deg F Module: Trina:TSM-300DD05A.18(II) 270.6 Vdrop= (9.19 150 0.00124 Ohms) / 246.49 0.69 Inverter 3: Branch: 9.19 100 AWG#10 at Max Ave Hi:87 deg F Vdrop= (9.19 200 0.00124 Ohms) / 293.4 0.92 Module: Trina:TSM-300DD05A.18(II) 270.6 Inverter 4: Total voltage drop in DC conductors= 1.62 Inverter: 21.6 15 AWG#10 at 240V Total: 17 Modules Vdrop= (21.6 30 0.00124 Ohms) / 240 V 0.14 Total Inv Pwr: 5200 4485.2 PTC Combined: at 240V Photovoltaic Module Electrical Specifications: Total STC: 5100 Vdrop= Ohms) / 240 V Voc: 39.9 V deg F deg C Vmp: 32.6 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.14 Isc: 9.64 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= Imp: 9.19 A Record Hi Temp: Tvoc: -0.12 V/deg C Tisc: 4.82 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf TVoc Data Branch Circuit Type A 1 way wire length: N/A Delta Solivia 5.2 TL Voc Correction Factor: Inverter Min Vdc Input: 146 1 strings per branch 1 1 strings per branch 2 9 Trina:TSM 300DD05A.18(II) 9 modules per seriesstring Voc= 359.1 Min Vmp at Max Temp: 246.49 8 Imodules per series string Max Voc at Min Temp: 398.67 Voc= 359.1 V Voc= 319.2 V Vmp= 293.4 Vmp= 293.4 V Vmp= 260.8 V Isc= 9.64 Inverter Max Vdc Input: 600 Imp= 9.19 Max String Size: 13 Isc= 9.64 A Isc= 9.64 A 1-way wire length: 100 Imp= 9.19 A Imp= 9.19 A Icont= 12.05 Art 690.8(A)(1) Icont= 12.05 A Icont= 12.05 A Art 690.8(A)(1) 1.a Conductor: AWG#10 PV Wire 2.a Conductor 1: N/A Conductor 2: N/A Icont*1.25=(Amps) 15.06 Conductor 1 Conductor 2 30 deg C ampacity= 40 Icont*1.25=(Amps) 15.06 15.06 1.b Icont=(Amps) 12.05 30 deg C ampacity= N/A N/A Start ampacity 40 2.b Icont=(Amps) 12.05 12.05 Temperature derate(%=F) 0.76 Start ampacity N/A N/A Conduit fill derate(%_#) 1 Temperature derate(%=F) N/A N/A Derated ampacity 30.4 Conduit fill derate(%=#) N/A N/A 1.c Derated ampacity N/A N/A Icont*1.25=(Amps) 15.06 2.c Term 1 Term 2 Ampacity 40 Temp table N/A N/A 1.d Icont 1.25=(Amps) 15.06 Icont*1.25=(Amps) 15.06 15.06 OCP Size= 20 Ampacity N/A N/A Inverter Type A Output 2.d OCP Size= I20 20 Delta Solivia 5.2 TL 1 way wire length: 15 ft Icont= 21.6 A Art 690.8(A)(1) Combined Inverter Output Service Voltage= 3.a Icont*1.25=(Amps)p ) 27 Art 690.8(6)(1) Total Inverter Power= 1 way wire length= 15 OCP Size= 30 Art 240.6(A) Icont=#of inverters max inverter current Art 690.8(A)(1) 3.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 (cont=(Amps) Icont*1.25=(Amps) 27 4.a Icont*1.25=(Amps) 27 Art 690.8(6)(1) 30 deg C ampacity= 40 OCP size= 30 Art 240.6(A) 3.c Icont=(Amps) 21.6 4.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 Icont*1.25=(Amps) 27 Temperature derate(%=F) 0.91 30 deg C ampacity= 40 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 21.6 Derated ampacity 36.4 Start ampacity 40 3.d Icont*1.25=(Amps) 27 Temperature derate(%=F) 0.91 Ampacity 35 Conduit fill derate(%=#) 1 Derated ampacity 36.4 4.d Icont*1.25=(Amps) 27 Ampacity 35 CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9723845 00 PREMISE OWNER: DESCRIPTION: DESIGN: D CONTAINED SHALL NOT BE USED FOR THE KEVIN CR A WFOR D Kevin Crawford RESIDENCE Derrick Olds _ BENEFIT ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: T s S L n SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13265 SW ASH AVE 5.1 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITHU THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-300DDO5A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: PERMISSION OF TESLA INC. SHEET: REV: DATE: Delta # Solivia 5.2 TL ELECTRICAL CALCULATIONS 6 10/13/2017 CAUTION: SOLAR CIRCUIT' Label Location: Label Location: t Label Location: ) MAXIMUM AC A (AC)(POI) WARNING Label Location: Per Code: OPERATING CURRENT (P01) IFC 605.11.1.4 MAxIMUM Ac Per Code: OPERATING VOLTAGEaimi V NEC 690.54 INVERTER OUTPUT NEC Code: Label Location: CONNECTION NEC 690.64.8.7 PHOTOVOLTAIC DC (DC)(INV) DO NOT RELOCATE DISCONNECT THIS OVERCURRENT Per Code: DEVICE NEC 690.14.C.2 Label Location: WARN NG (AC)(POI) Per Code: ELECTRIC SHOCK HAZARD Label Location: Do DICT T( UGH TIERTINALS` NEC 690.17(4) A/�/ Label Location: MAXIMUM POWER �a (DC)(INV) TERMINALSON BOTH LINE AND W�//� N I �' (DC)(INV) POINT CURRENT(Imp)- LOAD SIDES MAY BE ENERGIZED Per Code: MAXIMUM POWER Per Code: IN THE OPEN POSITION ELECTRIC SHOCK HAZARD POINT VOLTAGE(Vmp)�V NEC 690.53 THE DC CONDUCTORS OF THIS NEC 690.35(F) MAXIMUM SYSTEM PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN V7LTAGE(Voc} vUNGRt7UNDED'AND INVERTER IS SHORT CIRCUIT- MAY BE'ENERGIZED CURRENT(Ise) A UNGROUNDED Label Location: PV SYSTEM (AC) DISCONNECT FOR UTILITY OPERATION Label Location: WARNING (DC)(CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) TERMINALS ON BOTH LINE AND Label Location: PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION INTERCONNECTION DC VOLTAGE IS WARNING ELECTRIC SHOCK Per Code: ALWAYS PRESENT WHEN HAZARD.DO NOT TOUCH NEC 690.17.4; NEC 690.54 SOLAR ARE TERMINALS.TERMINALS ON EXPOSED SOLAR MODULES SUNLIGHT T BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC allil WARNING (DC)(INV) OPERATING CURRENT A Per Code: MAXIMUIvf AC ELECTRIC SHOCK HAZARD OPERATING VOLTAGE V IF AGROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: CAUTION (P01) DUAL POWER SOURCE Per Code: Label Location: SECOND SOURCE IS PHOTOVOLTAIC AC (AC)(P01) PHOTOVOLTAIC SYSTEM NEC 690.64.B.4 DISCONNECT Per Code: (AC):AC Disconnect NEC 690.14.C.2 (C): Conduit Label Location: (CB): Combiner Box CAUTION (D) (P01) (D): Distribution Panel PHOTOVOLTAIC SYSTEM (DC): DC Disconnect CIRCUIT Is BACKFED NEC 690.64.8.4 (IC): Interior Run Conduit Per Code: (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (P01): Point of Interconnection Label Set STORAGE SYSTEM LABELS ENERGY STORAGE SYSTEM ON SITE Label Location: BACKUP LOAD CENTER Label Location: Service Disconnect Backup load Center (BLC) LOCATED WITHIN LINE OF SIGHT Per Code: NEC 408.4 CAUTION Label Location: Back up load Center (BLC) Label Location: DO NOT ADD NEW LOADS Per Code: ENERGY STORAGE SYSTEM ON SITE Service Disconnect NEC 220 LOCATED ON ADJACENT WALL CAUTION Label Location: Main Panel THIS PANEL HAS SPLICED FEED- Per Code: ENERGY STORAGE SYSTEM ON SITELabel Location: THROUGH CONDUCTORS. NEC 312.8(3) Service Disconnect LOCATION OF DISCONNECT AT ENERGY LOCATED ON OPPOSITE WALL STORAGE BACK UP LOAD PANEL WAR N I N Label Location: ENERGY STORAGE SYSTEM ON SITE Service Location: Main Panel Disconnect INVERTER OUTPUT CONNECTION LOCATED INSIDE Per Code: DO NOT RELOCATE THIS NEC 705.12.D.2.3.b OVERCURRENT DEVICE WARNING Label Location: THIS EQUIPMENT FED BY MULTIPLE Main Panel CAUTION Label Location: SOURCES. TOTAL RATING OF ALL Per Code: DUAL POWER SOURCE Main Panel OVERCURRENT DEVICES, EXCLUDING NEC 705.12.D.2.3.c SECOND SOURCE IS Per Code: MAIN SUPPLY OVERCURRENT DEVICE, ENERGY STORAGE SYSTEM NEC 705.12.D.3 SHALL NOT EXCEED AMPACITY OF BUSBAR. lif *I 'HENT L F w ?ft�Ii1L R�E 'Lim 4- *4* twila 1 i T H Tie 1H 7E 96 THE . N1 T THE ORM 4F aLiaarr INC, 8 Z Comp Edge Zone Calculations 1 of 4 Zep Solar 3/26/15 ZS Comp Edge Zone Calculations 2 of 4 eo 3/26/15 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= Allowable Down Force Load checked. module width x design load Wind Down Calculations General Design Information: All variable the same as above except for roof pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph Roof Pitch System Weight= 3 psf Ground Snow Load= 30 psf 14 30 45 GCN landscape= 0.5 0.9 0.9 Comp Mount Allowable Loads GCN portrait= 0.4 0.9 0.9 load design R g landscape= 15.35 27.64 27.64 psf Load Duration Wind Snow Uplift= 656 lbs N/A - .-iii design load Lateral= 357 lbs 290 lbs portrait= 12.28 27.64 27.64 psf 85818 Down Force= 1074 lbs note:use 10 psf minimum 771 lbs OREGON Snow Calculations fir. To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment SpacingCalculations ':44-0,,,t- 'R,0'` Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 Uplift Spacing EXPIRES- 1201degrees. /15 uplift spacing= Allowable Uplift Load FOR PAGES 1-4 module length or width x design load Ground Snow Load= 30 psf Wind Uplift Calculations Roof Pitch 2014 OSSC and ASCE 7-10 Method 2 14 I 30 p=qh GCN Design Snow Load 29.11 25.98 psf qh=0.00256 lc Kit Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 120 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof Kit= 1.0 per 6.5.7.2 D+0.6*W= 12.91 19.18 psf Vorst Case Roof Pitch= 14 degrees K D+0.75*0.6*W+0.755 31.59 3 -:`'psf d= 0.85 from Table6-4 Roof Height= 30 GCN landscape=-1.6 Allowable Spacing for Down Force Iscape effective area= 13.0 ft2 GCN portrait=-1.5 portrait effective area= 21.7 ft2 down spacing landscape7711bs in force = x144-=89" Plandscape= -49.13 psf 39"x 31.91psf ftz qh= 30.71 psf Pportrait= -46.06 psf portrait downspacing 7711bs in force Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) p g= 65"x 31.91psf x 144 ftz =53" design load landscape= -27.73 psf design load portrait= -25.89 psf e uplift s spacing 656 lbs in landsca pP g = 39"x 27.73 psf x 144 ftz =87" s 656 lbs in portrait uplift spacing g = x144 2=56" 65"x 25.89 psf ft ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 • Ze 3/26/15 Za 3/26/15 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing=-1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load Maximum Uplift Pressure Landscape= -27.73 lateral spacing= module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf p5=C5 pf Roof Pitch= 31 45 degrees landscape module spacing= -1.4545 x 31.91 psf+120.7273 = 74" pf=0.7CeCfIpg Ce= 0.9 C5= 0.71 0.45 Cf= 1.2 pf= 22.68 22.7 psf portrait module spacing= -0.8182 x 31.91 psf+79.909= 54" = 1.0 p5= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral 30° 2 30 Lateral Force Component 4"' 44'* Down Force Load Roof Pitch Module Deflection 4"I 54" Combinations: 27 30 31 45 D+S= 13.50 L4 49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 2901bs in landscape lateral spacing= 39"x 14.49 psf x 144 ft2 =74" 2901bs in portrait lateral spacing = 65"x 14.49 psf x 144 ft2 =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2901bs in portrait lateral spacing= 65"x 13.50 psf x 144 ft2 =48" ` •'_ Model RSS-600 4-2 Connection Diagram: r_ € _ DELTA RAPID SHUTDOWN BOX �_. ',,,, _ tpNPy ON ROOF WITHIN 10'OF PV . rr b , . .-mac • CV5 € =. • € a C US a r'� �- ,� �i is € 'xi"mer; z�, .. � €l `[�r.,�, ryE € , 4 ' i_f�- ;,100 tfig , 8° DCPV+ a,E AC AC:,».- - : DC PS- One conduit ::: AKER GRID - ....._ _ AC for all wiring itI — f ' 5V SIGNAL ¢e .._ Technical Specifications Input Ratings I 'Ill: 3 � Max�aysle [tape = 600V 00 5b0V t C �_ avrrrrs 31ated Input Currenef t _ 1' 4 115122 x mer Rated Input Curtrin l'-' 20A _ 10A: > IST Fuse Rating N/A 15A Output Ratings lumbero€Ott T 1 2 ted'Output Curr gt per Ci cull20A 20A t` ' Maximum Current C troted Conductor 25A QutputTerm€nalWreSze DAWG t - Output Conduit Size' N/A 3/4 # idles) Control S€gnaJ TAitttto PLC;;Signat ;5V'Si l Wire // ' n SV Signal Wire Vottage eting !A 60W EV Signal Wire S Ttange t{A 14AWG i. Shutdown "`'� General Data Rapid "'tea Enclosure S3se'in Inches Lax 1N x D�rnrn) 7''',7 x 5.91* :08(2Q©4 i.5 tt 5 ) I2'',0-.:ii 44 x 10 aCa,'(5:(x'15 X 255 1 s.d iirsA� Weight 2rs(1?31s( .4gt Delta e I t� � 7. Inverters y y input Connectors MC-4 PV onne to or mphet of k4`Connector MO•t / �nhect r Amphenol H4 t srin tttr Device Output Connecters MC-4 PV onneetor-:o lmphen©l H4 Connector S rrrtln>l eks Operating Temperature 40-t F#40 70 ----E-_-3_3:1_ 15 F +{ b C} Delta's Rapid Shutdown Devices provide an automatic disconnect of 600VDC Storage Te perature 4Ei t s# (d0 8 } 4tf F#4@ 5 residential or small commericial PV array system,fully compliant with the Rapid Humidity �,x100% i-100% for Shutdown requirements of NEC 2014 article 690.12. It is compatible with Deltas May,Operat€ngAititud3 20�41t� zrveseaievef = bovc$eai et single-phase residential inverters. Warranty = TYears - 10Yea , KEY FEATURES Standard Compliance EnclosureProtectlopRat€ng RtAAX _ NEMA4�C •NEMA 4X Protection safety UL 174A 212.2691:47124_ - (x'11;CSA2 1T-1 •Compact and Lightweight NEC Code NEC2�i14A ce - ttty 014Artii e 2 •Rack Mount Installation = Delta Products Corporation,Inc. •Fast Connect with PV Connectors 46101 Fremont Blvd. •Compliant with NEC 2014 article 690.12 Fremont, CA 94538 Sales Email: Inverter.Sales@delta Corp.com •PLC Communication(Model RSS-600 1-1 only) Support Email: Inverter.Support@delta-corp.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 S�o Support Hotline: +1-877-442-4832 Support(Intl.): +1-626 369 8019 C I Us Monday to Pnday from lam to Spm PST(apart from Holidays) l./ (i �.� � oCii kELTA - wwLN.delta-americaS.COm WWW.delta-americas.COm�SOlarinverters Delta Solar Inverters Datasheet for SolarCity 'I- --II-:--- t4iglreiiIR INPUT(DC) 600 V 380 V 85-550 V 200-500 V 189 A 20,0 A 20.0 A per MPP tracker t ' , 25.0 A per MPP tracker w oicyCity i I I 4200 W 5000 5600 W S 1 b Internal t- 07-4I - ' SoIarCity ', ,,,,,-, :I OUTPUT(AC) - , 3000W38W5200W 66° W7600w 3000W@208Vi 33°°W2°8V1 52°°W@2°8VI 6::W:2°8VI 660 0 W°20 8VI 3000w@240v3800;@240V52001@240V0W240V7600W0240 183-228V@208V/211264V@240V 144 A@ 208 V/ 15.8A@208V/ 24.0 A@208 tit 31,7 p,@ 20,8,v/ 34.7 A@ 208V/ , ' 1 12.5 A@240V 15.8 A@ 240 V 21.6 A0240 V 27.5 A@ 240 V 31,7A@ 240V , 8 • - 60 Hz ,, 59.3-60.5 14z, . 6 C' v , 570-63.0 Hz ,x 15 W <3% ›699 0.85i-0.85c <50 db(A)@ Im - ';.741,4r,,, -----_-----r-t-1,- . : . 4:-.-z-- ' GENERAL SPECIFICATION 98% :`-'7--t"--r-r;(1.C11:',',-'?:'4',1, /01-!,": ' --, --,' 1,--- 97.6%@ 208V/97,5%@ 240V 1 '''ll11-:',4itfl::,/it',i'':',"":„,tP,4 _ 11 • --, 4 l f - vll,kit,,, „i ,r,,,,lif „ ' _ .._,,_ ,, _ -13-158°F(25-70°C)I.derating 122°F(50°C) v 1 __v., ......4. .... I ,. - vv-'-4 ' ' ' -40 185 FI 40 85 C) 0-100% 2000m above sea level MECHANICAL DESIGN ' 12.5 x 15.8 x 88 S1(495 x 401 x 216 atm) 26.80 15.8x 8.5 in(680x 401 x 216 mrn) 43.0lbs(ig-6 kg) 65.0 lbs(29.5 kg) . Natural Convectien. Spring terminals in conneetton box AWG - AWG 12-AWG 6 Copper(According to NEC 31015) 2 pairs of spring terminals in connection box 4 pairs of spring terminals in connection box AWG 12-AWG 6 Copper(According to NEC 690.8) ZigBee 3 LEDs,4-Line LCD Diecast Aluminum STANDARDS/DIRECTIVES NEMA 4X,1E060068-2-11 Sett mist Solar Inverters UL 1741 Second Edition,CSA 022,2 No 107.1-01 UL 1998 Transformerless (TL): 3.8 kW, 5.2 kW, 6.6 kW, 7.6 kW NEC 690.35,UL 1741 CRD IEEE 1547,IEEE 1547.1 FCC part 15 Class B , • Wide Operating Voltage Range:85-550V 1JL 169913(Type 1)NEC 690.11 UL 1741 CAD PVFISS,NEC 690.12(with SMART ASS) • Wide Operating Temperature Range:-13- 158°F(-25•--70°C) ANSIC121(meet 1%Accuracy) California Rule 21,RECO Compliant 1EEE1547 • High CEC Efficiency: 97.5% WARRANTY - Integrated AFCI (Arc Fault Circuit Interruption) 10 years . - NEMA 4X plus Salt Mist Corrosion Protection Delto Prodacts Corporation,Inc. 46101 Fremont Blvd, • Natural Convection Cooling Fremont,CA 94538 Sales Email iriverter saloslSdeltaww corn • Dual MPPT(5.2kW/6.6kW/7.6kW) Sales Hotline:+1-877-440-5851 or+1-626-369-8021 Support Hotline:+1-877-442-4832 • Compact and Lightweight Support(Intl.):+1-626-369-8019 61 hELTil • UL 1741 /IEEE 1547/IEEE 1547.1 /CEC Monday to Friday from 7 arn to 5 pm PST(apart from Holidays) (J' fiII Listed/UL 1699B(Type 1)/NEC 690.11 ELT c US POWER WALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use.Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, load shifting,and backup. Powerwali's electrical interface provides a simple connection to any home or building.Its revolutionary compact design achieves market-leading energy density and is easy to install,enabling owners to quickly realize the benefits of reliable,clean power. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240 V Dimensions 1150 mm x 755 mm x 155 mm (45.3 in x 29.7 in x 6.1 in) Feed-In Type Split Phase Weight 125 kg(276 lbs) Grid Frequency 60 Hz _....... Mounting options Floor or wall mount Total Energy 14 kWh Usable Energy 13.5 kWh 755 mm 155 mm (29.7 in) (6.1 in). Real Power,max continuous 5 kW(charge and discharge) . _. Real Power,peak(1001 7 kW(discharge only) Apparent Power,max continuous 5.8 kVA(charge and discharge) Apparent Power,peak(10s) 7.2 kVA(discharge only) Maximum Supply Fault Current 10 kA... Maximum Output Fault Current 32 A 1(45.3 in) 15037 Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/.1.0 adjustable Power Factor Range(full-rated power) +/ 0.85 __ C Internal Battery DC Voltage 50 V Round Trip Efficiency'' 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS 'Values provided tor 25&C.)77°F)3.s kW oharge/dres,af ge power. '.AO to battery to AC at brgronretf of Ste. Operating Temperature -2(1°C to 50°C(-4'F to 122°F) Operating Humidity(RH) Up to 100%,condensing Storage Conditions —20°C to 30°C(4W to 86W) COMPLIANCE INFORMATION Up to 95%RH,non-condensing State of Energy(SoE):.25%initial Certifications UL 1642,UL 1741,UI..1973, Maximum Elevation 3000 m(9843 ft) UL 9540,UN 38.3 ___ _...... _ _...... --- -- - ---- - - - -- - - Environment Indoor and outdoor rated Grid Connection Worldwide Compatibility - --- ---- ---- --- - --- --- -- -- __ Enclosure Type NEMA 3R Ernissions FCC Pari 15 Class B,ICES 003 - ---- ---- ---- --- ---- ---- - -- -- ---- --- --- ---- --- --- - -.-- Ingress Rating IF67(Battery&Power Electronics) Environmental RoHS Directive 2011/65/EU IPSO(Wiring Compartment) Seismic AC156,IEEE 693-2005(high) Wet Location Rating Yes Pollution Degree Rating _... P03. _....... Noise Level e lm <40 dBA at 30°C(86°F) TES LFI F8.A COM/ENERGY Mono Multi Solutions T 4 X1'1 ou 1t FRAMED 60-CELL MODULE E..._..W.�...d._,-��._.�..,a..._.._ ._...,.,�,_......__....,, PRODUCTS POWER RANGE ELECTRICAL DATA(SIC) THE 7 - TSM-DD05A.18(I1) 1 280-305W Peak Power Watts-Pour(Wp)` 275 280 - 285 290 295 300 305 [ Power Output Tolerancefimax(W} ;0»+5 ----- , Tana ill o LJ nt 1,---_-.*' ; ,,r.._ 1�, .__�_..,( DIMENSIONS OF PV MODULE(mmJinches) Maximum Power Voltage-Vm.M - 31.4 31.7 31.8 32.2 32.5 32.6 32.9 1 s v3za Maximum Power Cul-rent-tawr(A) -- 8.76 8,84 8.97 i9.01 9.08 9.19 9.29• _-- MODULE .-_, a Open Circuit Voltage Voc M 38.7 39.0 39.3 39.5 39.7 39.9 40.2 ae m. t__ ... ---4-- .4. - -4--_,.. -1 j LI Ill 1 o Short Circuit-Current-Isc(A) 926 935 945 '.'9,50 - 935 9.64 9.72 -lam Module Efficiency cy rh(%) 16.8. 17.1 17.4 17.7 18.0 18.3 18.6 POWER WALL Backup Gateway IIThe Backup Gateway for Tesla Powerwall provides energy management and monitoring for solar self-consumption,load shifting,and whole- home or partial-home backup. The Backup Gateway controls connection to the grid,automatically detecting outages and providing a seamless transition to backup power.When equipped with a circuit breaker,the Backup Gateway can b. 'be installed at the service entrance. art The Backup Gateway communicates directly with Powerwall,allowing you to monitor home energy Use and manage backup energy reservesfrom any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS h AC Voltage(Nominal) 230 V.120/240 V Dimensions 740 mm x 378 mm x 129 mm ilitt Feed-In Type Single&Split Phase (29 1 n x 14.9 in x 5.1 in) _... _ Weight 16.4 kg(36 lbs) Grid Frequency 50 and 60 Hz - - -- -- Mounting options Wall mount Disconnect Current 200 A i'i Maximum Input Short Circuit Current 10kA 378mm 129mm Overcurrent Protection Device' 100--200 A;Service Entrance Rated (14.9 in) (5.1 in) Overvoltage Category Category III BIP*4 AC Meter Revenue grade(+/-1%) r Connectivity Ethernet,Cellular(30),Wi-Fi II User Interface tesla App ( Operating Modes Support for solar self-consumption, load shifting,and backup 740 mm Backup Operation Automatic disconnect for seamless (29.1 in) backup transition Modularity Supports up to 10 AC-coupled Powerwalls Warranty _.. 10 years II __.. Tut breaker required fer installation at service entrance_ COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS0 Certifications UL 1642,UL 1741,IEC 62109-1, Operating Temperature --20CC to 50"C(4'F to 122'F) CSA 022.2.107.1 ''' -- --- -.. . - ---- -.--.. -.-.-- Operating Humidity(RH) Up to 100%,condensing Grid Connection Worldwide Compatibility - - --- ---- ---- --- _...... Maximum Elevation 3000 m(9843 ft) Emissions FCC Part 15 Class B,ICES 003, -- --- ---- ---- ---- - - IEC 61000-6-3,EN 55024, Environment Indoor and outdoor rated EN 301489-1,EN 301489-7, Enclosure Type NEMA 3R EN 301489-17 __.. _..... _..... __ _ _._. Ingress Rating IP44 Environmental RoHS Directive 2011/65/EU, - --- ---- ---- ---- ---- ---- -- WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation Seismic AC156,IEEE 693-2005(high) TvSL EsrAco7