Loading...
Plans (132) VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION nrj. DOCUMENTS AND OTHER DATA SHALL NOT PREVENT N` ,V 1. 4 Z017 THE CODE OFFICIAL FROM 4 REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 0 Tog ,.:.*)4 34)(3'1- 16Gn ArJGLC 2*'i 1"SCRay./ �1 P1 I C ES 1 PL Fl C 3/8",r y C'oNCRer ursiT DA•,:gvAIL - 4- PtrCE5 c RauND $"714 K CoNcRCTC 5LAV r Acw DowN TE1AIL CITY OF TIGARD REVII WLD FOR CODE COMPLIANCE 3 1----�� Approved: OTC: i I Permit#: ,A I - O Address: catWar 0 )0 Suite#: By' Date: Lt (r 1166°• OFFICE COPY MAGNo HUMNR1E- 1 Iez SW COMM CIffL. Sr. RNGL1= DETAIL TIG A(Zi> cREG1or.! TAB 3 ocoas farrier SUBMITTAL Project Magno Date Tuesday, August 22, 2017 Larry Goodroe Airefco, Inc dew 90 rodst Table Of Contents Project:-Untitled38 08/22/2017 Prepared By:Larry Goodroe 12:47PN HP-1 3 Unit Report 4 Performance Summary 4 Acoustic Summary 5 Certified Drawing 10 Unit Feature Sheet 12 15 Commercial Split Systems Builder 1.39g Page 2 of 12 Project:—Unt tled38 HP-1 Prepared By:Larry Goodroe 08/22/201 12:47P HP-1 Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Commercial Split Systems Builder 1.39g Page 3 of 12 Unit Report For HP-I Project:-Untitled38 08/22/2017 Prepared By:Larry Goodroe 12:47PN • ' ' •:-Mr; Outdoor Unit Parameters Unit Quantity:., 1 Unit ModeU 38AUQ Unit Size. 10 Tons Voltage' 230-3-60 V-Ph-Hz No.of DX Circuits:..............„...... . .. 1 System Parameter System Quantity.............................................I Refrigerant Type: PURON Compressor Quantity: 1 Compressor Type. Hermetic Std,Capacity Steps' 100 No.of Outdoor fans: 2 Outdoor Unit Dimensions and Weight Unit Length' 4 11.4" Unit Width: 3'9.9" Unit Height: 4"2.4" Unit Shipping Weight. 470 lb Unit Operating . ....... .... ... 575 lb Warranty Information(Note:for US&Canada only) NOTE: Please see Warranty Catalog 808-218 for explanation of policies and ordering methods. Ordering Information Part Base Unit-Outdoor 38AUQD12A0A5-0A0A0 1 Base Unit Al/Cu Condensing Coil Single Circuit Dual Stage Refrigerant Options 1 Service Options-None 1 Electrical Options-None 1 Packaging Options-Standard 1 Standard Electrical Mechanical Controls 1 Refrig Circ/Compressor Staging-Single Circuit/Dual Stage(size 07, 1 08, 12 only) Commercial Split Systems Builder 1.39g Page 4 of 12 • Performance Summary For HP-1 Project:—Untitled38 08/22/2017 Prepared By:Larry Goodroe 12:47PN • System: System Quantity- 38AUQ012 1 Altitude: 1 EER @ ARI Conditions: 11.0 ft IEER• .0 Hi TempCOP• 13.8 IPLV: 3.3 Suction Line Loss. NA System meets ASHRAE 90.1 min EER requirement. 1.4 °F Liquid and Suction Line Sizing Pipe Length Liquid Line Size Suction Line Size 0-25 1/2 1 1/8 26-50 1/2 11/8 51-75 1/2 1 1/8 76-100 1/2 1 1/8 Outdoor Unit Parameters Unit Quantity:1 PartNumber: 38AUQD12A0A5-0A0A0 Unit Model: 38AUQ Unit Size: 10 Tons No.of DX Circuits: 1 Voltage: 230-3-60 V-Ph-Hz Cig Ent Air DB: 95.0 °F Htg Ent Air DB: 47.0 °F Outdoor Electrical Data Unit Voltage: 2304-60 V-Ph-Hz Unit#1 MCA 39.0 Amps Unit#1 MOCP: 50.0 Amps Total Compressor Power of Unit#1: NA Voltage Range Min: 187 V Voltage Range Max: 253 V Compressor RIA: 15.9/15.6 Compressor LRA: 1101110 Compressor Quantity: 1 Fan Motors Qty: 2 Notice:Outdoor unit elect.data is based on 230-3-60 *Single Circuit,Two-Stage Compressor Option Heat Pump System Htg HP Capacity: 104.00 MBH Htg HP Integrated Capacity: 104.00 MBH Heating HP Compressor Power:7.38 kW Htg Ent Air DB Temp: 70.0 °F Htg Lvg Alr DB: 94.1 °F . High Temp COP: 3.3 • Commercial Split Systems Builder 1.39g Page 5 of 12 Performance Summary For HP-1 Project:—Untitled38 08/22/2017 Prepared By:Larry Goodroe 12:47PN Acoustics Sound Power Levels,db re 10E-12 Watts Outdoor Unit(dB) A-Weighted Total Level 84.2 63Hz 84.8 125Hz 92.0 250Hz 80.8 500Hz 82.6 1000Hz 78.4 2000Hz 74.0 4000Hz 69.2 8000Hz 67.8 Sound Message Sound foraug012 Acoustic Note: 1.The indoor sound power data is estimated sound power levels.It is based upon a limited amount of actual testing with the estimated sound power being generated from this data in accordance with ARI standard 370 for large outdoor refrigerating and air-conditioning equipment. 2.The indoor duct sound power data is estimated based on the ASHRAE calculation approach from the ASHRAE handbook 1987 HVAC Systems&Applications,Chapter 52. 3.The acoustic center of the unit is located at the geometric center of the unit. 4.All estimated sound power levels,dB re 1 Picowatt should not be guaranteed or certified as being the actual sound power levels. Commercial Split Systems Builder 1.39g Page 6 of 12 Performance Summary For HP-1 Project:-Untitled38 08/22/2017 Prepared By:Larry Goodroe 12:47PN Advanced Accoustics Parameters 1.Unit height above ground: 1.0 ft NQ >' 2.Horizontal distance from unit to receiver: 20.0 ft N 3.Receiver height above ground: 5,7 ft i • "irti7"--- \ 4.Height of obstruction: 0.0 ft ` 0 \\ o..••• \ Horizontal dist.from obstruction to receiver. 0.0 ft \ NiO 6.Horizontal dist.from unit to obstruction: 0.0 ft ; 0 N Detailed Acoustics Information Octave Band Center Frequency,Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center(Lw),dB 84.8 92.0 80.8 82.6 78.4 74.0 69.2 67.8 93.6 A-Wgted Sound Power Levels at Unit's Acoustic Center(LwA),dBA 58.6 75.9 72.2 79.4 78.4 75.2 70.2 66.7 84.2 Sound Press.Levels at Dist.Specified above(Lp),dB 60.5 67.7 56.5 58.3 54.1 49.7 44.9 43.5 69.3 A-Wgted Sound Press.Levels at Dist.Specified above(LpA),dBA 34.3 51.6,47.9 55.1 54.1,50.9 45.9 42.4 59.8 Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program,it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this,no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Commercial Split Systems Builder 1.39g Page 7 of 12 • • Acoustic Summary For HP-1 Project:-Untitled38 Prepared By:Larry Goodroe 08/22/201 12:47P Outdoor Unit Parameters: Tag Name: HP-1 Unit Model. 38AUQ Unit Size: 10 Tons • System Type: Dx Heat Pump _ Refrigerant Type: PURON Compressor Quantity: 1 ;4 Q Compressor Type. Hermetic SAdvanced Accoustics O 0 Parameters 1.Unit height above ground: 1.0 ft 0 `I 2.Horizontal distance from unit to receiver. 20.0 ft 3.Receiver height above ground: 5.7 ft 4.Height of obstruction: 0.0 ft 5.Horizontal distance from obstruction to receiver: 0.0 ft 6.Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Frequency,Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center(Lw),dB 84.8 92.0 80.8 82.6 78.4 74.0 69.2 67.8 93.6 A-Wgted Sound Power Levels at Unit's Acoustic Center(LwA),dBA 58.6 75.9 72.2 79.4 78.4 75.2 70.2 66.7 84.2 Sound Press.Levels at Dist.Specified above(Lp),dB 60.5 67.7 56.5 58.3 54.1 49.7 44.9 43.5 69.3 A-Wgted Sound Press.Levels at Dist.Specified above(LpA),dBA 34.3 51.6 47.9 55.1 54.1 50.9 45.9 42.4 59.8 Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program,it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this,no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Acoustic Note: 1.The indoor sound power data is estimated sound power levels.It is based upon a limited amount of actual testing with the estimated sound power being generated from this data in accordance with ARI standard 370 for large outdoor refrigerating and air-conditioning equipment. 2.The indoor duct sound power data is estimated based on the ASHRAE calculation approach from the ASHRAE handbook 1987 HVAC Systems&Applications,Chapter 52. 3.The acoustic center of the unit is located at the geometric center of the unit. 4.All estimated sound power levels,dB re 1 Picowatt should not be guaranteed or certified as being the actual sound power levels. Commercial Split Systems Builder 1.39g Page 8 of 12 • • Certified Drawing for HP-1 Project:-Untitied38 08122/201 Prepared By:Lany Goodroe 12:47P a1, (10C1iC4 30.all It. tail.) L [101.I (a./.c CON0 1 (line 0 604111, all 1151 [WKII)Ifli(f IIS. ) el. If 10. 0. III. 0. OS 14 1 ( 1 I 1101.1110(111 I1111•)•5,2N•M10,41.1.1I 171 10 IN II N iI ii N 11 1 1108.11 111117.11 11111.0 .2.1/1 1101.11 1141.11 10()1, 11I411.1•N.111.1.I1-SN.1.1 IS) Ill IN 61 1 11 II 0 lI 11 11140.61 (1 ISO.11 11 1311.0 4.1111111.01 11,07-Il(0(11) 151111.15.25.)-1).51-)-5 111 IN 15 N II 10 II 31 11 4 11111.11 0111).11 15111.11 14•11 11170.0 1147-110(11) /4471114.10,101.10,50.1.10 III III 14 0I It 11 U 4 IS 41 11(41.11 /11511.21 15 1140,11 34.314 111/1.11 1411.11.0(111 .1-5,110.1.11.51,-3.0 IN IN 10 N 111 f1 11 N 't0 N 10101.11 11114.21 lS 111.11 0.10 1101,71 3110-0 1100 111711.1.11,154.0.60.1.5 SBS 7n 10 1 , N / 11 14 III N 0101.11 71110.11 15111.11 0.314 1103.11 1142.11(11211 llll711•J•II.NO•YN-SN•)•0 Mi In 111 SI 1 4 if IB II II 111111.71 II(1511 71161.4 4.1111111.01 111,1A,11510111 7011711.1.11,40.1.1,S15.-N 31 111 14 5 )1 (1 it 30 II 11 13 1111.0 71110.51 (I 1111.21 040 11111.11 1114.111,11M1 -1.11,110-1.10.5(5-1.1, IN 11 14 41 11 Ii 11 li 011 I0 111151.71 tt(*14.11 it 1111.41 4.11(1111,11 1110.11 1111111.3.II,40.3.I.51.3.5 III 10 111 0 IN 11 II IS 111 Ii II 111,31. 211101.1) 211141.11 0.1110215.71 11301.11 III)/ lil4)0.1.11,112.0.11,515.1-4 166 a. In N 04 4 tie N 150 11 111w.5) 11110.11 2I(01.61 50-11117)1.71 1141-11172/ 1111111•)-11,160.1-N.57f.1-) IIS 231 III 10 111 51 Ii 1 011 It II 1111.61 21 101.71 14 041.41 $1.101 11/11.21 1141-1 177(1 I1I11.1..I.110.1.0.11,.1.1 01, el 11 11 I0 20 In 54 IN 1 11101.11 0113.51 21101.11 1.1)1171.21 30401 110l11.1.1I.i011.515•00 iii ill I5 0 51 4 10 10 41 I1 77151.11 411415.11 11131.0 44,1 001.0 711100.110 151710-1.1,1)-3.5.51.5•) 40 III I4, 11 1,I 55 If 30 10 II N 564.11 7I 00.11 1I 1113.13 111/1 11575.1 11140e,414) 211011.1.11,211.1.66.115-34I 12) 01 III II III 51 If II III II 1011141 21110.61 41 15011 10.11 11211.21 101.1? 20101.).1,,25.3.11,51.1.0 51$ 01 IN 41 1N 51 11 0 10 10 I1 1511.4 71 0011 tJ 101 21. 1.15 1111.21 NOTES: 1. MINIMUM CLEARANCE (LOCAL CODES OR JURISOICTEON MAY PREVAIL): A. BOTTOM 0 B.OUTDOORiO COlt. FOR(PROPER AIRBLE SEFLOW:1RNHES.INCHES ONE SIRE. 12 EKCHES THE OTHER. 7HE SIDE GETTING THE GREATER CLEARANCE IS OPTIONAL- STANDARD CLEARANCES ON REMAINING TRO SIDES. C.OVERHEAD: 60 INCHES. 10 ASSURE PROPER OUTDOOR FAN OPERATION. 0. BETREEN UNITS:CONTROL BOX SIDE. AZ INCHES PER NEC. E. BETWEEN UNIT AND UNGROUNDED SURFACES.CONTROL 80X T6BITNPC F. BEWEENUANDBLOCKOR CONCRETE NULLS AND OTHER GROUNDED SURFACES, CONTROL BOR SIDE. 42 INCHES PER NEC 2.WITH EXCEPTION Or THE CLEARANCE FOR THE OUTDOOR CDII AS STATED 11,NOTE 18. A REMOVABLE FENCE OR BARRICADE REQUIRES NO CLEARANCE. 3. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE FROM WOOD OR CLASS A, B OR C ROOF COVERING MATERIAL. 1T(l0714 38AU500319 Commercial Split Systems Builder 1.39g Page 9 of 12 • Certified Drawing for HP-1 Project:-Untided38 08/22/201? Preoared ay:Larry Goodroe 12:47PN ........... , ! "u". !,:‘`,."'**7,..ve,r,=.,!Vd."CLVIcr=1* wi!YYY.,Y,-..-!-,..,...,1 1.! ,iiMi''' -,'' gdziAlamo,,......,!-Y!!,''.'VfilaY,1"=?'"'I 4.4,,4,:,:e 144 4;Alitemilli ' . I * .7. ,4 11 1 1 1 I f ia7441117:sreif;, i 'M:cA:11111,1,. 14'lit&M'ii:V.--','—j;-11111,---7'), ,v.,,,...,,, ., t • , 1 ,,,,::::,,ori‘,,,,/ ar-*r=•'' . ' ' 1 II . 11.1.0.11111111014Wn I 1,040t.,, if RE -... AP viEr, TOP'Mt , ! it .il-I'I- ,Pliigai4 i .......... 1 I ' 'IVM i _____I :.1.7.f:ilf-: I.'--„ .MI=.; i I ---,.., I s"-C.D. I'I-TAI,It T.'t,,',In'4"1"„ ; 1 ,iffX.rtZ.VIITI--,, I i It I - , .,,,• , , i I . ineemammicausummorate I immimuitimmisate I I i ,,,, enemonnommumearann 1 I KM StM YEW 8,o1 --- ----'!,..,"-- L;0,,51.,I 1.0',,,,O.1,!;ILKF i„EFT&M VIEW '---[!:';t • i ...-4, --- FR=Vei i i 1 . im,ot HI ),14 i 1,3ii';,,'1: I 3:“,/: , l'f40 :. .i4.1-:.:- C1S !?.;14 1 3A'""" H 1._ Commercial Split Systems Builder 1.39g Page 10 of 12 - . - .. .. ' 0 cum ftwoocs Gemini - 38AUCI COMMERCIAL SPLIT SYSTEMS AIR-COOLED HEAT PUMP UNITS with PURON®REFRIGERANT 6 TO 20 TON These commercial quality air-cooled heat pump units are easily connected by refrigerant lines and low voltage control wiring to matching Carrier packaged air-handling units or other suitable evaporator units.They are ideal for new construction or renovation applications where quality and performance are required. ., . !A* Z 0 i f6r,:00 11 Certified to ISO 9001:2000 ATE , Iv I:, 1 COMIP „ Ptuon. BASE UNIT STANDARD FEATURES: • Puronfi (R-410A)HFC refrigerant partial charge • Single-stage cooling capacity control on models • All models utilize round copper tube,plate fin Condenser Coils • Standard one-year unit warranty and 5-year compressor plan • Cooling operating range up to 125 F(52 C)and down to 35 F(2 C) • Brass suction and liquid line service valves • Fully Hermetic Scroll compressor with crankcase heater and suction line accumulator • New terminal boom facilitating simple safety circuit troubleshooting and simplified control box arrangement. 24-volt 75va control system • High pressure and loss of charge protection. • Comfort AlertTM Diagnostic Board: • LED Go-No-Go and fault code • Built in time guard anti-short cycle • Phase protection • Fault code retention logic • Low voltage compressor contactor protector • UL and UL,Canada apply to standard units;575-volt units UL,Canada only. ARI_ . vral C 1(12,us stiatimmtone 1.0144 • Full perimeter base rails with built-in rigging adapters and fork truck slots • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection • Direct drive permanently lubricated condenser fan motors • All units factory run tested • Compressors mounted on independent vibration isolators Commercial Split Systems Builder 1.39g Page 11 of 12 TAB 4 ocoas SUBMITTAL Job Title: Mango Humphry's Elevation: (ft) 203 Date: 8/24/2017 Submitted By: Loren Adams JOHNSON AIR PRODUCTS 2220 SE 9TH AVENUE PO BOX 15098 PORTLAND, OR 97293 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: Iadams@johnsonair.com INGREENHECK Building Value in Air. P.O.Box 410 Schofield,WI 54476 (715)359-6171 FAX(715)355-2399 www.greenheck.com Generated by:ladams johnsonair.com CAPS 4.24.1283 G:Uob Data Files\Loren A\20171G-M\Mango Humphry's.gtcj Page 1 of 3 1NGREENHECK Printed Date: 8/24/2017 Job: Mango Humphry's Building Value in Air. Mark: Louver-Damper Combo Model: GCE-402 GCE-402 4 in. Frame, Gravity Exhaust Damper Blade APPLICATION & DESIGN GCE-402 is a combination weather louver and gravity backdraft damper designed to protect air exhaust openings in building exterior wall. Design incorporates a drainable head member,J style stationary louver blades,pressure/gravity operated damper blades and sloped sill to provide maximum resistance to rain and weather.Recommended application is in close proximity(preferably ducted)to an exhaust air fan as pressures required to operate the GCE-402 may exceed pressure differentials available without an adjacent fan. PRODUCT DETAILS Frame: 4 in.x 0.081 in.Frame Thickness Frame Type: Flanged,1.5 in.,Exterior Internal View Blades: 0.063 in,Adjustable Blade Thickness Material: Aluminum Sizing: Nominal Blade/Jamb Seals: Yes Axle Bearings: Synthetic Axle Material: Steel Shape: Rectangular furnishedwi.,,EI.,..,CDTE. SECT. Heal pGcp,tiTn:,...x,Ts,saEHt SECT. 1 1 p.ry.--,.0'_''.-25:1i n:n d er?),:::11 OPTIONS &ACCESSORIES Finish: Mill ,..„..,"7'?"*... ..* Bird Screen: 0.75 in.x 0.05 in.,Flat Expanded Aluminum,Internal, Mill Finish Warranty: 1 Yr(Standard)Product Warranty Width and Her SUMMARY ik ,,,, • ,' , T ' , , . . FREE FREE . DRIVE ACTUATOR S .6 19,1;,.. T?"i. : (:a1-1:‘, .W, (in4' H CIO AREA(fig)AREA(%*) ARRO. ! MODEL 'gi , ..,, 3-1 1 1 36 i 36 t 3.49 I 38,8 1 None 1 1 1 1 0 Total Louver Qty: 1 Total Weight(lb): 36 Louver Area(112): 9 Total Ship Sect.: 1 -*Weight shown rs an estimate only based on the defautt base product configtoetatn without opeons or aCCeSSOrt&S, Larger opernngs may reglatre bold assembly of multiple lottver panels to make up the overall opening sae.Indtwcioel louver panels are designed to withstand wIndloads up to a maximum or 25 PSF(sae and otedieuration dependant).Desige,materials and installation of structural reinforcement required 100dequetey st.pport large secaons or multiple seater,assentblres vetfial a large °venlig are not provided by Greenback.Unless specifically Mei:bated,the ttalowmg are NOT is.;ickided Cr the quote PrO`aded:shooter-al steel,malaaltan hardware fanch,ors.angle COO C0.5-q140U5 anMeS.slams,tasteners,Inserts,backer rod and sealant),field measuring and/or instatebon,miscellaneous flasnmg,tram or endue:4ms,blank off oaros,rtLation covers or mull on '-' hardware,hmged frames or removable subtrames,custom birdansect screen.a-coat,metallic endlor motto paint fimshes,bituminous Palate for ankke metala ant'aPfillcaofri taxes.stamPed and sealed structural calcutabons salsa=calm/aeons or job speak engineered submatal drawings, _ . Generated by:ladams@johnsonaircom CAPS 4.24.1283 GAJob Data Files‘Loren A‘20171G-M1Mango Humphry's.gfej Page 2 of 3 0.GREENHECK Printed Date: 8/24/2017 JoBuilding Value to Air. Mark: Lou er-DamperaMano gmper Model: GCE-402 Louvers Product Limited Warranty Thank you for purchasing Greenheck louvers.Greenheck warrants this equipment to be free from defect in material and workmanship for a period of 1 year from the date of product shipment.Any units or parts,which prove defective during the warranty period,will be repaired or replaced at our option when returned to our factory,transportation prepaid.Unless agreed upon otherwise Greenheck will not be held responsible for costs associated with removal or Installation of product(s). The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer.This limited warranty will be void if payment from Customer Is not received within a commercially reasonable time frame.GREENHECK MAKES NO OTHER WARRANTY,EITHER EXPRESS OR IMPLIED.REGARDING ITS PRODUCTS,OR ITS SELECTION AND APPLICATION,INCLUDING,BUT NOT LIMITED TO,COMPLIANCE WITH BUILDING CODES,SAFETY CODES,LAWS,MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE.This limited warranty Is extended solely to the Customer.It is nontransferable and non-assignable,and the Customer shall not permit or authorize its employees,agents,representatives or customers to claim,represent or imply that this limited warranty extends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty,Greenheck shall have no liability for and product failure claims. Failure to pay Greenheck in Ml for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s)replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period. Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. This limited warranty may not be modified by anyone and may not be changed by such things as purchase order forms or acceptance forms,unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations,Including,but not limited to,those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail,postage prepaid,return receipt requested to: Greenheck,Attn: Louver Sates,525 Western Road,Schofield,WI 54476. By proceeding to use our products and services on your project,you accept the terms of these limited warranties. Generated by:ladams@johnsonalr.com CAPS 4.24.1283 G:1Job Data Files1Loren A120171G-M\Mango Humphry's.gfcj Page 3 of 3