Loading...
Permit CITY OF TIGARD MASTER PERMIT 111 2..- COMMUNITY DEVELOPMENT Permit#: MST2017-00452 13125 SW Hall Blvd.,Ti Date Issued: 11/22/2017 T[GAR.L and OR 97223 503.718.2439 9 Parcel: 2S 111 DA13800 Jurisdiction: Tigard Site address: 8890 SW GREENING LN Subdivision: APPLEWOOD PARK NO.3 Lot: 131 Project: GANDA Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $4,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 5 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof to PV system 5.8 KW N P P Y Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: GANDA,ELVIS J&LAURA SOLARCITY CORPORATION Required Items and Reports(Conditions) 8890 SW GREENING LN 6132 NE 112TH AVE TIGARD,OR 97224 PORTLAND,OR 97220 PHONE: PHONE: 503-894-6903 FAX: 866-445-7459 Total Fees: $518.52 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OA 952-001-0090. Y u may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued /(: �10 By: -C% i�-� Permittee Signature: l�G L< (,af � Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application r Residential l()lt()tNlt ! O51.1f0i 1 City of Tigard ,. ,, 'I:(:,\r' i O i DatclBy Permit No v 1111 r, 13125 SW Hall Blvd Tigard,OR 97223 Plan ily: i` l&/� ' �/�"Ul 2_� /S2. Y Other Permit; Phone: 503.718,2439 Fax: 503.598.1944 l t ,y UatelDv: T 1 ,#t?t l Inspection Line: 503.639.4175 - ; ' , D a t c Rcadye liy: lard: See Page 2 for Internet; www.tigard-or.gov Notified/Method: / 17 Supplemental Information rift WORK of 1.ANIBB.F Q New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the , - work indicated on this application. ttl-and 2-family1► �lI oPCammerctal/i�ndu Valuation: $ 4000 dwellingatrial ❑Accessory building 0 Multi-family Number of bedrooms; Master builder 0 Other: Number of bathrooms: „.. — E, - JOB sinITl FOIBBA M"RF3 B f�It , ” Total number of floors: Job site address: 8890 SW Greening reeving Ln, Newdwelling area: square feet City/State/ZIP: Tigard,OR 97224 Garage/earport area: square feet Suite/bldg./apt.no.: Project name: Elvis Ganda Covered porch area: square feet Cross street/directions to job site; Deck area: square feet Other structure area: square feet REQVIR : DATAtbMM to `CH KLI T Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/panel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the s_. azsciurrio OF W I <; >... work indicated on this application. Valuation: $ PV ROOF MOUNT Existing building area: square feet 5.8 KW New building area: square feet ger POO ,l Ty o ` R , _ ' 0 TEM = , Number of stories: Name: Elvis Ganda Type of construction: Address: 8890 SW Greening Ln, Occupancy groups: City/State/ZIP: Tigard, OR 97224 Existing: Phone:(562 ) 881 8215 Fax:( ) New: F � t P ath ` 1 t er t 4' Business name: _.... - 3 ;".,. . `,. _ ; salareity Corp Structural plan review fee(or deposit): Contact name: Melissa Farias FLS plan review fee(if applicable): Address:6132 NE 112th Ave. Total fees due upon application: City/State/ZIP: Portland OR 97220 Phone:( ) fax::( Amount received: 503 $94-6903 186ff 445-7459 ,' t a, " All P a E-mail:Melissa.Farias@SolarCity.com �€ ' Commercial and residential prescriptive installation of 10.,r ,,‘, -:-4m ._ :! ,_I ' r .,...- .. roof-top mounted PhotoVoltaic Solar Panel System. Business name:SolarCi(y Corp. Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon• Address: 6132 NE 112th Ave Solar Installation Specialty Code checklist. City/State/ZIP: Portland OR 97220 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 503) 894-6903 Fax:(186(1 44S-7459 State surcharge(12a%®ofpermit fee) $21.60 CCB lie.: 180498 Total fee due upon application: $201.60 • Authorized signaturesf )i( i This permit application expires if a permit is not obtained 4 *6.1 Ywithin 180 days after it has been accepted as complete. Print name: Melissa Fari. Date: 11.13.17 *Fee methodology set by fila-County Building Industry Service Board. 1:\Hui lding\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) o - ' Electrical Permit Application _ , l OR(Ill 1( l' 1 sl 0\1 \ IA U V 1 b Z017 Received City of Tigard Date/B : ICEINEMPM III,- 13125 SW Hall Blvd.,Tigard,OR 97221 i y (it: `i '.,4:-.:::‘1 I Plan Review Other Permit: Phone: 503.718.2439 Fax: $03.59p.) Inspection Line: 503.639.4175 c Ready/By:. 21 Sec Page 2 for Internet: www.tigard-or,gov Notified/Method: NMI Supplemental inforaintion i4;141.-Cfkitii*- ,'Il''' '''' "' ''' ''' i--- 11---'" a„--4,, Mot --AA:4Q,,,q .' ::'' Please check all that apply(submit,Z sets of plans writerns checked below); 0 New construction '''' Addition/alteration/replacement El Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition [7:1 91.h!,.... , , , where the available fault cunent 0 Marinas and boatyards. ii,.t.,,,,,',' 1,::,-;= exceeds 10,000 amps at 150 volts or 0 Floating buildings: PE C t''','):ae.‘vtPCTIQE '''^^'-------:''7' less to ground,or exceeds 14,000 0 Commercial-use agricultural E 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building amps for all other installations buildings. 0 Multi-family 0 Master builder , , 0 Other:_ T , 0 Emergency rnegetur0 Installation of 150 KVA or 0ncy.system. larger separately derived system. I 6',` SITE INDORNIAVD* AND L s -',,,''ts', El Addition of new motor load of 0"A","Ii",:1-2","1-3", 100111'or More. Job no.: Job site address: 8890 SW Greening Ln, 0 Six or mom residential units. 0 itenur,:ta7nin vehicle parks. City/State/ZIP: Tigard, OR 97224 13 Health-care facilities. 0 Supply voltage for more than 0 Nazardotts locations. 600 volts nominal. Suite/bldg./apt.no.: 1 Project name: Elvis Ganda El Service or feeder 600 amps or more. SCAB'4,ii11'i;' Cross street/directions to job site: Descripdaa Qt_y. Vet. Total New residential single-or multi-family dwelling unit. Includes attached garage, Subdivision: 1 L01 no.: 1,000 sq.ft.or less 168.54 4 Ea.addi 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: ,,.,,,„ _ ,, Limited energy,residential 75.00 2 - , -,:;:'11. tl N C°T-:...:11-W4AC -;;;--I'i.''---' Limited d1:1:rgyve strittlii-fam' multi-family 75.00 2 PV ROOF MOUNT residential(with above sq.11.) Renewable Energy ";' See Page 2 5.8 KW+ Energy Storage System services or feeders installation,alteration,and/or relocation = '---- --,--- 200 amps or less 1 100.70 100.70 2 -, - --, , 201 amps in 400 amps --7: ''2 1"':Al i::''' 'o ''''''--':::'-. ' - ':': - o TEMairr ' - 133.56 2 Name: Elvis Ganda401 amps to 600 amps 200.34 2 Address: 8890 SW Greening Ln, 601 301 amps to 1,000 amps -- -04 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP: Tigard,OR 97224 Temporary services or feeders installation,alteration,and/or Phone:( 562) 881-8215 1 Fax:( ) relocation 200 amps or less 5936 I Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: . .. ' -----1:*"t : Branch circuits-new,alteration,or extension,per panel i A.Fee for branch circuits with above service or feeder fee, 5 each branch circuit 7.42 37.10 2 Business name:SolarCity Corp. B.Fee for branch circuits without Contact name: Melissa Fariasservice or feeder fee,first 56,,18. 2 branch circuit Address: 6132 NE 112th Ave Each addi branch circuit 7.42 f 2 Miscellaneous(service or feeder not included) City/State/ZIP:Portland, OR 97220 Each manufactured or modular 67.84 2 Phone:(5 03 ) 894-6903 I Fax::(1866) 445-7459 dwelling,service and/or feeder Reconnect only 67.84 2 E-mail:melissa.Parias@Solar-rit ,.COM Pump or irrigation.circle 67.84 2 Sign or outline lighting 67.84 2 Business name: Signal circuit(s)or limited-energy See SolarCity Corp, panel,alteration,or extension. Page 2 2 Address: 6132 NE 112th Ave Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr City/State/ZIP: Portland OR 97220 ' Investigation(1 hr min) 66.25/hr 1_ __ _ phone:(--ii-.5) 894-6903 I Fax:4866) 445-7459 Industrial plant(I hr min) 78.18/hr Inspections for which no fee is , hr00.00,.hr Suprv.Lie.: 58735 . cd 5icall listed(.5 nun CCB Lie.: 180498 i Electrical Lie.: c562 IT Suprv.Electrician signature,required:Jt' - Subtotal: Plan review(25%of permit fee): Print name: Nicholas Armstrong Date: 11.13.17 State surcharge(12%of permit fee):. Authorized signature: ---- . , TOTAL PERMIT FEE: t 'Ills permit application expires if a permit is not obtained within 180 1 Date: 11.13.17 Print name: Melissa Faria ',„.',) days after If has been accepted as complete. " Number of inspections allowed per permit. TABtatidiargermits1ELC_PemnitApp_ELkERE.dac Rev 05/2 1+2015 440-4615TO IJOSICOMAVED i } Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: REI S !NIA. 4 4NL� . Fee for all residential systems combined $75.00 neveriptlor I Pec. ` r • Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100,70 2 5.01 t0l5kva 1 133.56 133.56 2 El Audio and Stereo Systems 15.01 to 25 kva 20034 -2 11 Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301_04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 5100 kva(tee in accordance with 552.26 2 ElHeating,Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systems In excess of 25 kva: each additional kva over 25 7.42 3 El Vacuum Systems* X100 kva-no additional charge 0.0 3 ❑ Each additional itlspectiun over allowable in any of the above: Other: Each additional inspection is 66.251 hr d charged at rod hourly(1 hr min) Inspections for which no fee is 90,00.'lir SpeCificalij,listed (',5 h CO ERC.I4L;WORK ONL ' £LCC3 in) Fee for each commercial system $75.00 Subtotal: (SEE OAR 91S-309-0000) Plan review,if required(25%ofpermit fee): State surcharge(12%ofpermit fee): Check Type of Work Involved: TOTAL PERMIT FEE: ❑ This permit application expires if a permit is not obtained within ISO Audio and Stereo Systems days after it has been accepted as complete. * Number of insp tions allowed per permit. n Boiler Controls El Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm installation ❑ HVAC I Instrumentation ❑ Intercom and Paging Systems El Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls El Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:lfduildulg:PrrmosTIZ.fernaIApp EI.R.131411 doc Rev 05/2/2013 fit: Cit of Tigard ��� ��+c �� y. g N 0 V 1 1a 21117 Building Division e l 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 301 d`s TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 8890 SW GREEING LN City: TIGARD Zip: 97224 Owner's Name: ELVIS GANDA Date: 11.13.17 Contractor's Name: SOLAR CITY CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure ® Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes N Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ® Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist.docx Is the construction Type of material wood and does ® Yes the construction qualify If"Yes", qualifies for Construction as "conventional light 111No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for Elthe 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is RoofingCheck the type of ❑ of wood Yp one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ID No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/Photovoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ID Yes "Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directlyto inches inches, qualifies for the Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 1:/Building/Forms/Photo V oltaic-Checkl ist.docx Submittal Documents required for Prescriptive,Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules • Manufacturer: REC Model Number: 260 Listing Agency: UL1703 4 I:/Building/Forms/Photovoltaic-Checklist.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8890 SW GREENING LN, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2017-00452 Inspection Type: Inspector: 199 Electrical final Jeff Grove Result: PASS Comments: Violation Summary: Inspector Contractor