Loading...
Report 4kiza/7 -602- CE1V 0-.0 w ),/-t , Date: June 27, 2017 OCT 6 2017 I 'OF TIG ARD _:.•••••••••••••••••••••••••m. Katie Stana Tower Engineering Professionals Crown Castle B1 IL"INC DIVISION 326 Tryon Road 2055 S. Stearman Drive Raleigh, NC 27603 Chandler, AZ 85286 (602) 845-1747 (919) 661-6351 crown(c�tepgroup.net Subject: Structural Analysis Report Carrier Designation: T-Mobile Co-Locate Carrier Site Number: PO01316D Carrier Site Name: 1-5 & Highway 217 Crown Castle Designation: Crown Castle BU Number: 824674 Crown Castle Site Name: 1-5 & Highway 217 Crown Castle JDE Job Number: 444541 Crown Castle Work Order Number: 1420913 Crown Castle Application Number: 395487 Rev. 0 Engineering Firm Designation: TEP Project Number: 37852.122902 Site Data: 14020 SW 72nd Ave., Tigard, Washington County, OR 97224 Latitude 45°25'11.37", Longitude-122°44'44.74" 98 Foot-Monopole Tower Dear Katie Stana, Tower Engineering Professionals is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 1050099, in accordance with application 395487, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Existing + Proposed Equipment Note:See Table I and Table II for the proposed and existing loading, respectively. Sufficient Capacity This analysis has been performed in accordance with the 2014 Oregon Structural Specialty Code (2012 International Building Code) based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per Section 1609.3.1 as required for use in the TIA-222-G Standard per Exception#5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. All modifications and equipment proposed in this report shall be installed in accordance with the appurtenances listed in Tables 1 and 2 and the attached drawing for the determined available structural capacity to be effective. We at Tower Engineering Professionals appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. S/RUC Ttio 4.4 Structural analysis prepared by: Timothy Vicisko/TSA PROP , Respectfully submitted by: William H. Martin, P.E., S.E. OREGON ' 7 „AS*444 1 .' ►0 EXPIRES: 12/31/2018 f r 98-ft Monopole Tower Structural Analysis Report June 27, 2017 TEP Project Number 37852.122902,Application 395487, Revision 0 CCI BU No 824674 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2)ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing Antenna and Cable Information Table 3- Design Antenna and Cable Information 3)ANALYSIS PROCEDURE Table 4- Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 5 -Section Capacity(Summary) Table 6-Tower Component Stresses vs. Capacity 4.1) Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations • L tnxTower Report-version 7.0.5.1 98-ft Monopole Tower Structural Analysis Report June 27, 2077 TEP Project Number 37852.122902,Application 395487, Revision 0 CC/BU No 824674 Page 3 1) INTRODUCTION This tower is a 98-ft monopole tower manufactured by Summit Manufacturing, Inc. and designed by Paul J. Ford & Company in January of 1996. The tower was originally designed for a wind speed of 85 mph per ANSI/EIA-222- E for the appurtenances listed in Table 3. TEP did not visit the site. All information provided to TEP was assumed to be accurate and complete. 2)ANALYSIS CRITERIA The analysis has been performed in accordance with the ANSI/TIA-222-G-2-2009 Structural Standard for Antenna Suggortino Structures and Antennas —Addendum 2 using a nominal 3-second gust wind speed of 93 mph with no ice, 30 mph with 1.0 inch ice thickness, and 60 mph under service loads with the following design criteria: T of Analysis: Rigorous Structural Analysis Classification of Structure: Class II Exoosure Category: Exposure C Topographic Catego : Category 1 Earthquake Category: Not Considered Earthquake effects may be ignored per this standard for site locations where Ss does not exceed (Site Location Ss= 0.974). 1.0. Table 1 -Proposed Antenna and Cable Information Center Nrt,m: Mounting Line Antenna �►n Number Feed Level (ft) Elevation tenna Model of Feed Line Note (ft) Antennas Manufacturer Lines Size(in) 3 Andrew TMZXXX-6516-A3M w/Mount Pipe 98.0 100.0 3 Nokia FHFB 3 Nokia FRLB 1 1-3/5 1 3 Nokia FRIJ 1 Raycap RNSDC-7771-PF-48 Notes: 1) See"Appendix B-Base Level Drawing"for assumed feed line configuration. Table 2 -Existing Antenna and Cable Information Center Number Mounting Line Antenna' Number Feed Level(ft) Elevation of Manufacturer Antenna Model of Feed Line Note (ft) Antennas Lines : Size(in) 3 SBNHH-1 D65C 7 Commscope 98.0 3 w/ Mount Pipe 16 7/8 100.0 Andrew ETM19V2S12UB 1 5/16 1 99.0 3 Commscope TME-ETM19V2S12UB i 98.0 d 1 Tower Mounts (Platform Mount[LP 601-1] 2 Notes: 1 1) Existing equipment 2) Existing equipment to be removed;not considered in this analysis ,_ tnxTower Report-version 7.0.5.1 98-ft Monopole Tower Structural Analysis Report June 27, 2017 TEP Project Number 37852.122902,Application 395487, Revision 0 CCI BU No 824674 Page 4 Table 3 -Design Antenna and Cable Information Mounting CenterLie Number of Antenna Number Feed Levu{ft) Elevation Manufacturer Antenna Model of Feed Line { ) Antennas Lines Size in 98.0 98.0 12 { ) . . _ Decibel DB978 85.0 85.0 1 Generic 4-ft Dish w/Radome (6 GHz) 50.0 50.0 1 Generic 4-ft Dish w/Radome (6 GHz) - 3)ANALYSIS PROCEDURE Table 4- Documents Provided Document Remarks Reference Source Geotechnical Report Dames& Moore I 3510067 CCISites Tower Foundation Drawings Miller Consulting Engineers 3510066 Tower Manufacturer Drawings Paul J. Ford and Company 3510068 CCISites CCISites 3.1) Analysis Method tnxTower(version 7.0.5.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) The tower and foundation were built in accordance with the manufacturer's specifications. 2) The tower and foundation have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2, and "Appendix B—Base Level Drawing". 4) All tower components are in sufficient condition to carry their full design capacity. 5) Serviceability with respect to antenna twist, tilt, roll, or lateral translation, is not checked and is left to the carrier or tower owner to ensure conformance. 6) All antenna mounts and mounting hardware are structurally sufficient to carry the full design capacity requirements of appurtenance wind area and weight as provided by the original manufacturer specifications. It is the carrier's responsibility to ensure compliance to the structural limitations of the existing and/or proposed antenna mounts. TEP did not analyze antennas supporting mounts as part of this structural analysis report. This analysis may be affected if any assumptions are not valid or have been made in error. Tower Engineering Professionals should be notified to determine the effect on the structural integrity of the tower. tnxTower Report-version 7.0.5.1 98-ft Monopole Tower Structural Analysis Report June 27, 2017 TEP Project Number 37852.122902,Application 395487, Revision 0 CC/BU No 824674 Page 5 4)ANALYSIS RESULTS Table 5 -Section Capacity(Summary) SectionComponent No. Elevation(ft) J Size Critical Type Element P(Ib) pai'°W(lb) %Capacity Pass/Fail Li 98-63 Pole TP19.071x13.75x0.188 1 --- -3292.20 818126.00 68.7 Pass L2 63-30.5 Pole TP23. 38x18.316x0.188 2 6 -5703.75 956996.00 ' 101.4 Pass' L3 30.5-0 Pole TP27.9x22.731 x0.25 3 -9492.56 1479940.00 . 91.0 Pass Summary Pole(L2) 101.4 Pass' Rating= 101.4 Table 6 -Tower Component Stresses vs. Capacity Notes Component Elevation(ft) %Capacity Pass/Fail 2 Anchor Rods - 51.4 Pass 2 Base Plate 74.1 2 Base Foundation Soil Interaction - Pass 86.3 Pass 2 Base Foundation Structural _ - - 82.0 Pass Structure Rating (max from all components) = J 101.4% Notes: 1) A structure rating of 105%or less is within engineering tolerances and considered acceptable. 2) See additional documentation in"Appendix C-Additional Calculations"for calculations supporting the%capacity listed. 4.1) Recommendations 1) If the load differs from that described in Tables 1 and 2 of this report, "Appendix B —Base Level Drawing" or the provisions of this analysis are found to be invalid, another structural analysis should be performed. 2) The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. tnxTower Report-version 7.0.5.1 98-ft Monopole Tower Structural Analysis Report June 27, 2017 TEP Project Number 37852.122902, Application 395487, Revision 0 CC/BU No 824674 6 Page 6 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 7.0.5.1 I 98.0 ft i � l DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION I I I (2)3"x 6"SideLight 198 FHFB 98 -- 1. 2.4"Dia x Oft Mount Pipe 198 FRLB 98 SBNHH-1D65C w/Mount Pipe 198 FRLB 98 SBNHH-1 D65C w/Mount Pipe 98 .—__....—__....—. FRLB ............._ ..---...._.__... ._... ....__98_...._—.....— ..y 111 SBNHH-1D65C w/Mount Pipe 98 FRIJ 98 . 11 ETM19V2S12UB 98 FRIJ 98 o mIII ETM19V2S12UB '98 -- FRIJ 98 .� 1 w ^o ma it ETM19V2S12UB 98' RNSDC-7771-PF-48 98 0 `�' °' II TMZXXX-6516-A3M w/Mount Pipe 98 2.4"Dia.x 6'Mount Pipe 98 TMZXXX-6516-A3M w/Mount Pipe 982.4" (4)2 4 Dia x 6 Mount Pipe 98 TMZXXX-6516-A3M w/Mount Pipe !98 2.4"Dia.x 6'Mount Pipe 98 it j FHFB ......--- __.........___ g8 ..._____.. .__ Platform Mount[LP 601-1] 98 FHFB _._.....----........ __.. ii MATERIAL STRENGTH GRADE Fy.—_...__ Fu GRADE . Fu _ ...._—... i A607-65 65 ksi 80 ksi A607-60 , 60 ksi 175 ksilir A TOWER DESIGN NOTES I 1. Tower is located in Washington County,Oregon. 63.0 ft 4 2. Tower designed for Exposure C to the TIA-222-G Standard. II 3. Tower designed for a 93 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 1.00 in ice.Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. i 1 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING:101.4% 11 ii • II 8i Q `rico t sn I 11 1111 i ' Gp .—._._—..... ... .... ........__ ._..... 30.5 ft L 4 1 9 II i l ALL REACTIONS it ARE FACTORED it S I AXIAL 22899/b n 1 roE n m• 11 SHEAR MOMENT I 1226 Ib 107641/b-ft 1 TORQUE 163/b-ft 11, 30 mph WIND-1.000 in ICE AXIAL 9504 lb SHEAR MOMENT I • 9531 lb r ` 759359 lb-ft 0.0 ft j TORQUE 738 lb-ft v a REACTIONS-93 mph WIND a '° m E Y n 8 n I ,- z F-- to F m (7 1 3 Tower Engineering Professionals 'Ob'I--5&Highway 217(BU 824674) 326 Tryon Road Project:TEP No.37852.122902 Raleigh, NC 27603 Client:Crown Castle Drawn by:TSA Aped' Tower Engineering Professionals Phone:(919)661-6351 Code: TIA-222-G Date:06/27/17 Scale: N FAX:(919)661-6350 Path:c Dwg No. � � � Job Page 1-5 & Highway 217 (BU 824674) 1 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tiyon Road Raleigh,NC 27603 Client Phone:(919)661-6351 Designed by FAX.: (919)661-6350 Crown Castle TSA Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Washington County, Oregon. Basic wind speed of 93 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 1.000 in. Ice thickness is considered to increase with height. Ice density of 56 pcf A wind speed of 30 mph is used in combination with ice. Temperature drop of 50°F. Deflections calculated using a wind speed of 60 mph. A non-linear(P-delta)analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments-Diagonals ) Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification Ai Use Clear Spans For Wind Area SR Leg Bolts Resist Compression V Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable NI Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice i Bypass Mast Stability Checks V Consider Feed Line Torque Always Use Max Kz Ai Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile J Project Wind Area of Appurt. Use TIA-222-G Bracing Resist.Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-G Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC.6D+W Combination p `y p � Secondary Horizontal Braces Leg ) Sort Capacity Reports By Component ' Include Shear-Torsion Interaction Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius t t t Sides in in in in L1 98.00-63.00 35.00 2.500 18 13.750 19.071 0.188 0.750 A607-65 (65 ksi) L2 63.00-30.50 35.00 3.500 18 18.316 23.638 0.188 0.750 A607-65 (65 ksi) Job Page tnxTower1-5 & Highway 217 (BU 824674) 2 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX:(919)661-6350 TSA Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L3 30.50-0.00 34.00 18 22.731 27.900 0.250 1.000 A607-60 (60 ksi) Tapered Pole Properties Section Tip Dia. Area I r C I/C J It/Q w w/t in in2 in4 in in in3 in' in in LI 13.962 8.071 187.571 4.815 6.985 26.853 375.388 4.036 2.090 11.147 19.365 11.238 506.283 6.704 9.688 52.258 1013.232 5.620 3.026 16.141 L2 18.984 10.789 447.947 6.436 9.304 48.143 896.482 5.395 2.894 15.433 24.003 13.956 969.621 8.325 12.008 80.747 1940.518 6.979 3.830 20.428 L3 23.622 17.839 1138.988 7.981 11.547 98.637 2279.475 8.921 3.561 14.242 28.330 21.940 2119.189 9.816 14.173 149.521 4241.167 10.972 4.470 17.882 Tower Gusset Gusset Gusset Grade Adjust.Factor Adjust. Weight Mull. Double Angle Double Angle Double Angle Elevation Area Thickness Aj Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Spacing Diagonals Horizontals Redundants ft f2 in in in in LI 98.00-63.00 1 1 1 - L2 63.00-30.50 1 1 1 L3 30.50-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Component Placement Total Number Start/End Width or Perimeter Weight Type Number Per Row Position Diameter ft in in pf Safety Line 3/8 C Surface Ar 98.00-0.00 1 1 0.000 0.375 0.220 (CaAa) 0.000 Step Pegs(5/8"SR)7-in.w/30" C Surface Ar 98.00-0.00 1 1 0.000 0.350 0.487 step (CaAa) 0.000 ********** Feed Line/Linear Appurtenances Entered As Area Description Face Allow Component Placement Total C4AA Weight or Shield Type Number Leg ft ft2/ft pf 1/2"Cable(Lights) B No Inside Pole 98.00-0.00 1 No Ice 0.00 0.400 1/2"IIce 0.00 0.400 1" ce 0.00 0.400 *98* ATCB-B01(5/16) B No Inside Pole 98.00-0.00 1 No Ice 0.00 0.075 1/2"Ice 0.00 0.075 1"Ice 0.00 0.075 LDF5-50A(7/8) B No Inside Pole 98.00-0.00 16 No Ice 0.00 0.330 1/2"Ice 0.00 0.330 1"Ice 0.00 0.330 Job Page mxTower� 1-5 & Highway 217 (BU 824674) 3 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tiyon Road Raleigh,NC 27603 Client Phone:(919)661-6351 Designed by FAX:(919)661-6350 Crown Castle TSA Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft ft2/f Pf ASU9325TYP01(1-3/5) B No Inside Pole 98.00-0.00 1 No Ice 0.00 1.614 1/2"Ice 0.00 1.614 ********wt 1"Ice 0.00 1.614 Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Section Elevation In Face Out Face ft ft2 ft2 ft2 ft2 lb L 1 98.00-63.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 257.92 C 0.000 0.000 2.538 0.000 24.75 L2 63.00-30.50 A 0.000 0.000 0.000 0.000 0.00 - B 0.000 0.000 0.000 0.000 239.49 C 0.000 0.000 2.356 0.000 22.98 L3 30.50-0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 224.75 C 0.000 0.000 2.211 0.000 21.56 Feed Line/Linear`Appurtenances Section Areas - With Ice Tower Tower Face Ice AR AF CAAA CAAA Weight Section Elevation or Thickness In Face Out Face ft Leg in ft' ft' ft2 ft' lb LI 98.00-63.00 A 2.185 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 257.92 C 0.000 0.000 33.121 0.000 500.58 L2 63.00-30.50 A 2.069 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 239.49 C 0.000 0.000 30.755 0.000 464.83 L3 30.50-0.00 A 1.850 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 224.75 • C 0.000 0.000 27.458 0.000 396.62 Feed Line Center of Pressure Section Elevation CPQ CPz CPx CPz Ice Ice ft in in in in L1 98.00-63.00 0.000 0.104 0.000 0.735 L2 63.00-30.50 0.000 0.105 0.000 0.821 L3 30.50-0.00 0.000 0.105 0.000 0.856 Shielding Factor Ka itixTower Job Page 1-5& Highway 217 (BU 824674) 4 of 13 Project Date Tower Engineering Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tiyon Road Raleigh,NC 27603 Client Phone:(919)661-6351 Crown Castle Designed by FAX:(919)661-6350 TSA Tower Feed Line Description Feed Line K, K, Section Record No. Segment Elev. No Ice Ice L1 2 Safety Line 3/8 63.00-98.00 1.0000 1.0000 LI 3 Step Pegs(5/8"SR)7-in. 63.00-98.00 1.0000 1.0000 w/30"step L2 2 Safety Line 3/8 30.50-63.00 1.0000 1.0000 L2 3 Step Pegs(5/8"SR)7-in. 30.50-63.00 1.0000 1.0000 w/30"step Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ° ft ft2 f lb ft fi (2)3"x 6"SideLight B From 4.00 0.000 98.00 No Ice 0.09 0.09 0.98 Centroid-Le 0.000 1/2"Ice 0.14 0.14 2.46 - g 5.000 1"Ice 0.19 0.19 4.70 2.4"Dia x 4-ft Mount Pipe B From 4.00 0.000 98.00 No Ice 0.87 0.87 14.64 Centroid-Le 0.000 1/2"Ice 1.12 1.12 22.02 ***98*** g 3.000 1"Ice 1.37 1.37 32.24 SBNHH-1D65C w/Mount A From 4.00 30.000 98.00 No Ice 11.63 9.79 82.45 Pipe Centroid-Le 5.000 1/2"Ice 12.35 11.31 171.76 g 2.000 1"Ice 13.07 12.85 271.01 SBNHH-1D65C w/Mount B From 4.00 30.000 98.00 No Ice 11.63 9.79 82.45 Pipe Centroid-Le 5.000 1/2"Ice 12.35 11.31 171.76 g 2.000 1"Ice 13.07 12.85 271.01 SBNHH-1D65C w/Mount C From 4.00 25.000 98.00 No Ice 11.63 9.79 82.45 Pipe Centroid-Le 5.000 1/2"Ice 12.35 11.31 171.76 g 2.000 1"Ice 13.07 12.85 271.01 ETM19V2S12UB A From 4.00 30.000 98.00 No Ice 0.72 0.20 11.20 Centroid-Le 0.000 1/2"Ice 0.82 0.27 16.08 g 2.000 1"Ice 0.94 0.35 22.52 ETM19V2S12UB B From 4.00 30.000 98.00 No Ice 0.72 0.20 11.20 Centroid-Le 0.000 1/2"Ice 0.82 0.27 16.08 g 2.000 1"Ice 0.94 0.35 22.52 ETM19V2S12UB C From 4.00 25.000 98.00 No Ice 0.72 0.20 11.20 Centroid-Le 0.000 1/2"Ice 0.82 0.27 16.08 g 2.000 1"Ice 0.94 0.35 22.52 TMZXXX-6516-A3M w/ A From 4.00 30.000 98.00 No Ice 8.73 3.33 54.51 Mount Pipe Centroid-Le -5.000 1/2"Ice 9.18 4.01 111.96 g 2.000 1"Ice 9.63 4.66 175.98 TMZXXX-6516-A3M w/ B From 4.00 30.000 98.00 No Ice 8.73 3.33 54.51 Mount Pipe Centroid-Le -5.000 1/2"Ice 9.18 4.01 111.96 - g 2.000 1"Ice 9.63 4.66 175.98 - TMZXXX-6516-MM w/ C From 4.00 25.000 98.00 No Ice 8.73 3.33 54.51 Mount Pipe Centroid-Le -5.000 1/2"Ice 9.18 4.01 111.96 g 2.000 1"Ice 9.63 4.66 175.98 - FHFB A From 4.00 30.000 98.00 No Ice 3.63 2.39 52.90 Centroid-Le -5.000 1/2"Ice 3.89 2.62 80.57 g 2.000 1"Ice 4.15 2.85 111.97 FHFB B From 4.00 30.000 98.00 No Ice 3.63 2.39 52.90 • Job Page ° tnx ower 1-5& Highway 217 (BU 824674) 5 of 13 Project Date Tower Engineering Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Phone:(919)661-6351 Designed by Crown Castle FAX: (919)661-6350 TSA Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ° ft ft2 ft2 lb ft ft Centroid-Le -5.000 1/2"Ice 3.89 2.62 80.57 g 2.000 1"Ice 4.15 2.85 111.97 FHFB C From 4.00 25.000 98.00 No Ice 3.63 2.39 52.90 Centroid-Le -5.000 1/2"Ice 3.89 2.62 80.57 g 2.000 1"Ice 4.15 2.85 111.97 FRLB A From 4.00 30.000 98.00 No Ice 2.07 0.78 59.52 Centroid-Le 0.000 1/2"Ice 2.25 0.90 74.83 g 2.000 1"Ice 2.43 1.03 92.75 FRLB B From 4.00 30.000 98.00 No Ice 2.07 0.78 59.52 Centroid-Le 0.000 1/2"Ice 2.25 0.90 74.83 g 2.000 1"Ice 2.43 1.03 92.75 FRLB C From 4.00 25.000 98.00 No Ice 2.07 0.78 59.52 Centroid-Le 0.000 1/2"Ice 2.25 0.90 74.83 g 2.000 1"Ice 2.43 1.03 92.75 FRIJ A From 4.00 30.000 98.00 No Ice 2.43 1.01 44.10 Centroid-Le 5.000 1/2"Ice 2.63 1.16 60.48 g 2.000 1"Ice 2.84 1.32 79.68 FRIJ B From 4.00 30.000 98.00 No Ice 2.43 1.01 44.10 Centroid-Le 5.000 1/2"Ice 2.63 1.16 60.48 g 2.000 F Ice 2.84 1.32 79.68 FRIJ C From 4.00 25.000 98.00 No Ice 2.43 1.01 44.10 Centroid-Le 5.000 1/2"Ice 2.63 1.16 60.48 g 2.000 1"Ice 2.84 1.32 79.68 RNSDC-7771-PF-48 A From 4.00 30.000 98.00 No Ice 3.18 1.20 20.00 Centroid-Le 0.000 1/2"Ice 3.40 1.35 42.75 g 2.000 1"Ice 3.63 1.50 68.68 2.4"Dia.x 6'Mount Pipe A From 4.00 0.000 98.00 No Ice 1.43 1.43 21.90 Centroid-Le -2.500 1/2"Ice 1.93 1.93 37.81 g 0.000 1"Ice 2.31 2.31 55.56 (4)2.4"Dia.x 6'Mount Pipe B From 4.00 0.000 98.00 No Ice 1.43 1.43 21.90 Centroid-Le 0.000 1/2"Ice 1.93 1.93 37.81 g 0.000 1"Ice 2.31 2.31 55.56 2.4"Dia.x 6'Mount Pipe C From 4.00 0.000 98.00 No Ice 1.43 1.43 21.90 Centroid-Le -2.500 1/2"Ice 1.93 1.93 37.81 g 0.000 1"Ice 2.31 2.31 55.56 Platform Mount[LP 601-1] C None 0.000 98.00 No Ice 28.47 28.47 1122.00 1/2"Ice 33.59 33.59 1513.66 ************** 1"Ice 38.71 38.71 1905.31 Load Combinations Comb. Description - No. - 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg-No Ice 3 0.9 Dead+1.6 Wind 0 deg-No Ice 4 1.2 Dead+1.6 Wind 30 deg-No Ice 5 0.9 Dead+1.6 Wind 30 deg-No Ice 6 1.2 Dead+1.6 Wind 60 deg-No Ice 7 0.9 Dead+1.6 Wind 60 deg-No Ice t XTOWer Job Page 1-5& Highway 217 (BU 824674) 6 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX. (919)661-6350 TSA Comb. Description No. 8 1.2 Dead+1.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+1.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+1.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+1.6 Wind 240 deg-No Ice 20 1.2 Dead+1.6 Wind 270 deg-No Ice 21 0.9 Dead+1.6 Wind 270 deg-No Ice 22 1.2 Dead+1.6 Wind 300 deg-No Ice 23 0.9 Dead+1.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+1.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Maximum Member Forces Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. lb lb ft lb-ft L1 98-63 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -12438.38 -1838.65 -1174.03 Max.Mx 8 -3322.27 -208245.56 3064.34 Max.My 14 -3307.06 2959.98 -210083.18 Max.Vy 8 6903.30 -208245.56 3064.34 Max.Vx 14 6961.28 2959.98 -210083.18 Max.Torque 2 -757.92 L2 63-30.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -16851.51 -2029.14 -1742.59 Max.Mx 8 -5717.33 -446680.47 5994.44 � �werJob Page 1-5 & Highway 217 (BU 824674) 7 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tiyon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX: (919)661-6350 TSA Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. lb lb ft lb-ft Max.My 14 -5709.88 5888.21 -450367.28 Max.Vy 8 8205.46 -446680.47 5994.44 Max.Vx 14 8262.90 5888.21 -450367.28 Max.Torque 2 -750.02 L3 30.5-0 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -22899.45 -2083.77 -2276.35 Max.Mx 8 -9490.62 -747411.06 9042.24 Max.My 14 -9490.44 8965.69 -753045.69 Max.Vy 8 9427.23 -747411.06 9042.24 Max.Vx 14 9482.07 8965.69 -753045.69 Max.Torque 2 -740.44 Maximum Reactions Location Condition Gov. Vertical Horizontal,X Horizontal,Z Load lb lb lb Comb. Pole Max.Vert 30 22899.45 -1225.81 5.33 Max.Ha 20 9503.95 9413.80 -87.76 Max.H, 2 9503.95 -87.76 9468.54 Max.Mx 2 752548.49 -87.76 9468.54 Max.Mx 8 747411.06 -9413.80 87.76 Max.Torsion 14 710.15 87.76 -9468.54 Min.Vert 17 7127.96 4782.90 -8243.87 Min.H. 8 9503.95 -9413.80 87.76 Min.H, 14 9503.95 87.76 -9468.54 Min.M, 14 -753045.69 87.76 -9468.54 Min.M, 20 -746737.95 9413.80 -87.76 Min.Torsion 2 -737.87 -87.76 9468.54 Tower Mast Reaction Summary Load Vertical Shear,, Shear, Overturning Overturning Torque Combination Moment,M Moment,M lb lb lb lb ft lb-ft lb ft Dead Only 7919.96 0.00 0.00 202.29 -272.68 -0.00 1.2 Dead+1.6 Wind 0 deg-No 9503.95 87.76 -9468.54 -752548.49 -9616.99 737.87 Ice 0.9 Dead+1.6 Wind 0 deg-No 7127.96 87.76 -9468.54 -741759.70 -9380.65 724.52 Ice 1.2 Dead+1.6 Wind 30 deg-No 9503.95 4782.90 -8243.87 -656269.91 -381833.43 703.78 Ice 0.9 Dead+1.6 Wind 30 deg-No 7127.96 4782.90 -8243.87 -646864.45 -376237.62 688.89 Ice 1.2 Dead+1.6 Wind 60 deg-No 9503.95 8196.46 -4810.27 -384176.24 -651861.52 479.58 Ice 0.9 Dead+1.6 Wind 60 deg-No 7127.96 8196.46 -4810.27 -378686.68 -642379.00 467.16 Ice 1.2 Dead+1.6 Wind 90 deg-No 9503.95 9413.80 -87.76 -9042.30 -747411.06 134.63 - Ice 0.9 Dead+1.6 Wind 90 deg-No 7127.96 9413.80 -87.76 -8960.37 -736552.96 127.82 Ice 1.2 Dead+1.6 Wind 120 deg- 9503.95 8108.71 4658.27 368683.80 -642744.66 -237.04 � �� �� Job Page 1-5 & Highway 217 (BU 824674) 8 of 13 Tower Engineering Project Date -- Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX (919)661-6350 TSA Load Vertical Shear„ Shear, Overturning Overturning Torque Combination Moment,M, Moment,M lb lb lb lbft lbft lb-ft No Ice 0.9 Dead+1.6 Wind 120 deg- 7127.96 8108.71 4658.27 363311.59 -633399.27 -236.62 No Ice 1.2 Dead+1.6 Wind 150 deg- 9503.95 4630.90 8156.11 647653.80 -365840.58 -542.83 No Ice 0.9 Dead+1.6 Wind 150 deg- 7127.96 4630.90 8156.11 638252.24 -360495.70 -535.30 No Ice 1.2 Dead+1.6 Wind 180 deg- 9503.95 -87.76 9468.54 753045.69 8965.99 -710.15 No Ice 0.9 Dead+1.6 Wind 180 deg- 7127.96 -87.76 9468.54 742124.20 8904.99 -697.42 No Ice 1.2 Dead+1.6 Wind 210 deg- 9503.95 -4782.90 8243.87 656758.32 381176.24 -697.40 No Ice 0.9 Dead+1.6 Wind 210 deg- 7127.96 -4782.90 8243.87 647222.68 375757.50 -682.67 No Ice 1.2 Dead+1.6 Wind 240 deg- 9503.95 -8196.46 4810.27 384666.29 651193.27 -500.94 No Ice ` 0.9 Dead+1.6 Wind 240 deg- 7127.96 -8196.46 4810.27 379046.09 641890.97 -488.03 No Ice 1.2 Dead+1.6 Wind 270 deg- 9503.95 -9413.80 87.76 9542.79 746737.95 -162.34 No Ice 0.9 Dead+1.6 Wind 270 deg- 7127.96 -9413.80 87.76 9327.24 736061.48 -154.90 No Ice 1.2 Dead+1.6 Wind 300 deg- 9503.95 -8108.71 -4658.27 -368174.51 642077.76 230.72 No Ice ' 0.9 Dead+1.6 Wind 300 deg- 7127.96 -8108.71 4658.27 -362938.43 632912.24 230.41 No Ice 1.2 Dead+1.6 Wind 330 deg- 9503.95 -4630.90 -8156.11 -647146.16 365184.76 564.16 No Ice 0.9 Dead+1.6 Wind 330 deg- 7127.96 4630.90 -8156.11 -637880.27 360016.59 556.17 No Ice 1.2 Dead+1.0 Ice+1.0 Temp 22899.45 0.03 0.03 2276.35 -2083.77 -0.55 1.2 Dead+1.0 Wind 0 deg+1.0 22899.45 5.34 -1165.02 -97606.85 -2751.39 147.08 Ice+1.0 Temp 1.2 Dead+1.0 Wind 30 deg+1.0 22899.45 585.12 -1011.49 -84576.28 -52389.74 162.34 Ice+1.0 Temp 1.2 Dead+1.0 Wind 60 deg+1.0 22899.45 1008.12 -587.06 -48240.05 -88551.49 133.85 Ice+1.0 Temp 1.2 Dead+1.0 Wind 90 deg+1.0 22899.45 1225.81 -5.33 1635.50 -107628.47 70.16 Ice+1.0 Temp 1.2 Dead+1.0 Wind 120 22899.45 1002.79 577.83 51688.20 -87897.45 -13.64 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 150 22899.45 575.88 1006.16 88503.78 -51256.49 -93.19 deg+1.0 Ice+-1.0 Temp 1.2 Dead+1.0 Wind 180 22899.45 -5.32 1165.04 102186.66 -1442.90 -147.93 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 210 22899.45 -585.11 1011.49 89157.17 48192.70 -163.41 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 240 22899.45 -1008.11 587.06 52820.80 84353.55 -135.21 deg+1.0 Ice+1.0 Temp - 1.2 Dead+1.0 Wind 270 22899.45 -1225.79 5.34 2943.93 103432.68 -71.59 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 300 22899.45 -1002.78 -577.83 -47105.85 83699.17 12.46 ' deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 330 22899.45 -575.88 -1006.16 -83921.29 47059.10 92.28 deg+1.0 Ice+1.0 Temp Dead+Wind 0 deg-Service 7919.96 20.43 -2203.92 -174225.73 -2433.74 173.93 Dead+Wind 30 deg-Service 7919.96 1113.28 -1918.86 -151932.92 -88691.58 167.53 Dead+Wind 60 deg-Service 7919.96 1907.82 -1119.65 -88873.42 -151260.50 116.12 Dead+Wind 90 deg-Service 7919.96 2191.17 -20.43 -1943.94 -173374.25 34.02 Dead+Wind 120 deg-Service 7919.96 1887.40 1084.27 85563.51 -149110.20 -56.68 Job Page ' wer 1-5 & Highway 217 (BU 824674) 9 of 13 Project Date Tower Engineering Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tiyon Road Raleigh,NC 27603 Client Phone:(919)661-6351 Crown Castle Designed by FAX (919)661-6350 TSA Load Vertical Shear, Shears Overturning Overturning Torque Combination Moment,M, Moment,M lb lb lb 1b711 lb ft lb ft Dead+Wind 150 deg-Service 7919.96 1077.90 1898.43 150199.60 -84964.64 -132.07 Dead+Wind 180 deg-Service 7919.96 -20.43 2203.92 174642.61 1871.14 -172.47 Dead+Wind 210 deg-Service 7919.96 -1113.28 1918.86 152349.40 88128.70 -167.20 Dead+Wind 240 deg-Service 7919.96 -1907.82 1119.65 89289.97 150697.11 -117.26 Dead+Wind 270 deg-Service 7919.96 -2191.17 20.43 2360.97 172810.65 -35.49 Dead+Wind 300 deg-Service 7919.96 -1887.40 -1084.27 -85146.07 148546.87 56.34 Dead+Wind 330 deg-Service 7919.96 -1077.90 -1898.43 -149782.24 84401.82 133.19 1 Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX Comb. lb lb lb PY PZ %Error lb lb lb 1 0.00 -7919.96 0.00 -0.00 7919.96 -0.00 0.000% 2 87.76 -9503.95 -9468.54 -87.76 9503.95 9468.54 0.000% 3 87.76 -7127.96 -9468.54 -87.76 7127.96 9468.54 0.000% 4 4782.90 -9503.95 -8243.87 -4782.90 9503.95 8243.87 0.000% 5 4782.90 -7127.96 -8243.87 -4782.90 7127.96 8243.87 0.000% 6 8196.46 -9503.95 -4810.27 -8196.46 9503.95 4810.27 0.000% 7 8196.46 -7127.96 -4810.27 -8196.46 7127.96 4810.27 0.000% 8 9413.80 -9503.95 -87.76 -9413.80 9503.95 87.76 0.000% 9 9413.80 -7127.96 -87.76 -9413.80 7127.96 87.76 0.000% 10 8108.71 -9503.95 4658.27 -8108.71 9503.95 -4658.27 0.000% 11 8108.71 -7127.96 4658.27 -8108.71 7127.96 -4658.27 0.000% 12 4630.90 -9503.95 8156.11 -4630.90 9503.95 -8156.11 0.000% 13 4630.90 -7127.96 8156.11 -4630.90 7127.96 -8156.11 0.000% 14 -87.76 -9503.95 9468.54 87.76 9503.95 -9468.54 0.000% 15 -87.76 -7127.96 9468.54 87.76 7127.96 -9468.54 0.000% 16 -4782.90 -9503.95 8243.87 4782.90 9503.95 -8243.87 0.000% 17 -4782.90 -7127.96 8243.87 4782.90 7127.96 -8243.87 0.000% 18 -8196.46 -9503.95 4810.27 8196.46 9503.95 -4810.27 0.000% 19 -8196.46 -7127.96 4810.27 8196.46 7127.96 -4810.27 0.000% 20 -9413.80 -9503.95 87.76 9413.80 9503.95 -87.76 0.000% 21 -9413.80 -7127.96 87.76 9413.80 7127.96 -87.76 0.000% 22 -8108.71 -9503.95 -4658.27 8108.71 9503.95 4658.27 0.000% 23 -8108.71 -7127.96 -4658.27 8108.71 7127.96 4658.27 0.000% 24 -4630.90 -9503.95 -8156.11 4630.90 9503.95 8156.11 0.000% 25 -4630.90 -7127.96 -8156.11 4630.90 7127.96 8156.11 0.000% 26 0.00 -22899.45 0.00 -0.03 22899.45 -0.03 0.000% 27 5.33 -22899.45 -1164.85 -5.34 22899.45 1165.02 0.001% 28 585.09 -22899.45 -1011.46 -585.12 22899.45 1011.49 0.000% 29 1008.08 -22899.45 -587.04 -1008.12 22899.45 587.06 0.000% 30 1225.61 -22899.45 -5.33 -1225.81 22899.45 5.33 0.001% 31 1002.75 -22899.45 577.81 -1002.79 22899.45 -577.83 0.000% 32 575.86 -22899.45 1006.13 -575.88 22899.45 -1006.16 0.000% 33 -5.33 -22899.45 1164.85 5.32 22899.45 -1165.04 0.001% 34 -585.09 -22899.45 1011.46 585.11 22899.45 -1011.49 0.000% 35 -1008.08 -22899.45 587.04 1008.11 22899.45 -587.06 0.000% 36 -1225.61 -22899.45 5.33 1225.79 22899.45 -5.34 0.001% 37 -1002.75 -22899.45 -577.81 1002.78 22899.45 577.83 0.000% - 38 -575.86 -22899.45 -1006.13 575.88 22899.45 1006.16 0.000% 39 20.43 -7919.96 -2203.91 -20.43 7919.96 2203.92 0.000% 40 1113.28 -7919.96 -1918.86 -1113.28 7919.96 1918.86 0.000% 41 1907.82 -7919.96 -1119.65 -1907.82 7919.96 1119.65 0.000% 42 2191.17 -7919.96 -20.43 -2191.17 7919.96 20.43 0.000% 43 1887.40 -7919.96 1084.27 -1887.40 7919.96 -1084.27 0.000% 44 1077.90 -7919.96 1898.43 -1077.90 7919.96 -1898.43 0.000% 45 -20.43 -7919.96 2203.91 20.43 7919.96 -2203.92 0.000% � � Job Page 1-5 & Highway 217 (BU 824674) 10 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Phone:(919)661-6351 Designed by FAX:(919)661-6350 Crown Castle TSA Sum of Applied Forces Sum of Reactions Load PA' PY PZ PA' PY PZ %Error Comb. lb lb lb lb lb lb 46 ' -1113.28 -7919.96 1918.86 1113.28 7919.96 -1918.86 0.000% 47 -1907.82 -7919.96 1119.65 1907.82 7919.96 -1119.65 0.000% 48 -2191.17 -7919.96 20.43 2191.17 7919.96 -20.43 0.000% 49 -1887.40 -7919.96 -1084.27 1887.40 7919.96 1084.27 0.000% 50 -1077.90 -7919.96 -1898.43 1077.90 7919.96 1898.43 0.000% Non-Linear Convergence Results Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 5 0.00000001 0.00053721 3 Yes 5 0.00000001 0.00019925 4 Yes 6 0.00000001 0.00028920 5 Yes 6 0.00000001 0.00006826 6 Yes 6 0.00000001 0.00026578 7 Yes 6 0.00000001 0.00006077 8 Yes 5 0.00000001 0.00015091 9 Yes 5 0.00000001 0.00005697 10 Yes 6 0.00000001 0.00027163 11 Yes 6 0.00000001 0.00006416 12 Yes 6 0.00000001 0.00028788 13 Yes 6 0.00000001 0.00006938 14 Yes 5 0.00000001 0.00010036 15 Yes 5 0.00000001 0.00003851 16 Yes 6 0.00000001 0.00026175 17 Yes 6 0.00000001 0.00005960 18 Yes 6 0.00000001 0.00028418 19 Yes 6 0.00000001 0.00006666 20 Yes 5 0.00000001 0.00029086 21 Yes 5 0.00000001 0.00010697 22 Yes 6 0.00000001 0.00028009 23 Yes 6 0.00000001 0.00006707 24 Yes 6 0.00000001 0.00026460 25 Yes 6 0.00000001 0.00006214 26 Yes 4 0.00000001 0.00020068 27 Yes 5 0.00041021 0.00086763 28 Yes 6 0.00000001 0.00026299 29 Yes 6 0.00000001 0.00024862 30 Yes 5 0.00041281 0.00096444 31 Yes 6 0.00000001 0.00026520 32 Yes 6 0.00000001 0.00027124 33 Yes 5 0.00041239 0.00092378 34 Yes 6 0.00000001 0.00024340 35 Yes 6 0.00000001 0.00025480 36 Yes 5 0.00040734 0.00088912 37 Yes 6 0.00000001 0.00022563 38 Yes 6 0.00000001 0.00022333 39 Yes 4 0.00000001 0.00067223 40 Yes 5 0.00000001 0.00017654 41 Yes 5 0.00000001 0.00014995 42 Yes 4 0.00000001 0.00030019 43 Yes 5 0.00000001 0.00014290 44 Yes 5 0.00000001 0.00016171 45 Yes 4 0.00000001 0.00053461 46 Yes 5 0.00000001 0.00014599 for Job Page 1-5 & Highway 217 (BU 824674) 11 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle TSA FAX: (919)661-6350 47 Yes 5 0.00000001 0.00016917 48 Yes 4 0.00000001 0.00035033 49 Yes 5 0.00000001 0.00014922 50 Yes 5 0.00000001 0.00013383 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L 1 98-63 26.769 46 2.465 0.011 L2 65.5-30.5 11.762 46 1.809 0.004 L3 34-0 2.966 46 0.812 0.001 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 98.00 (2)3"x 6"SideLight 46 26.769 2.465 0.011 11507 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L 1 98-63 114.852 16 10.626 0.046 L2 65.5-30.5 50.633 16 7.805 0.018 L3 34-0 12.795 16 3.504 0.006 Critical Deflections and Radius of Curvature Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 98.00 (2)3"x 6"SideLight 16 114.852 10.626 0.047 2843 Compression Checks Pole Design Data tnxTower Job Page 1-5 & Highway 217 (BU 824674) 12 of 13 Project Date Tower Engineering Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tryon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 FAX. (919)661-6350 Crown Castle TSA Section Elevation Size L Lu Kl/r A Pu 4Pn Ratio No. Pu ft f ft in2 lb lb rap L1 98-63(I) TP19.071x13.75x0.188 35.00 0.00 0.0 11.012 -3289.95 818126.00 0.004 L2 63-30.5(2) TP23.638x18.316x0.188 35.00 0.00 0.0 13.639 -5701.46 956996.00 0.006 4.8.2(1.01 CR)-2 L3 30.5-0(3) TP27.9x22.731x0.25 34.00 0.00 0.0 21.940 -9490.24 1479940.00 0.006 Pole Bending Design Data Section Elevation Size Mux 4M, Ratio Mr rpMn Ratio No. Mux y M v ft lb ft lb-ft 4,Mu,, lb-ft lb-ft ()My Ll 98-63(1) TP19.071x13.75x0.188 212149.17 310589.17 0.683 0.00 310589.17 0.000 L2 63-30.5(2) TP23.638x18.316x0.188 454502.50 450865.00 1.008 0.00 450865.00 0.000 L3 30.5-0(3) TP27.9x22.731x0.25 759359.17 840475.00 0.903 0.00 840475.00 0.000 Pole Shear Design Data Section Elevation Size Actual 4V„ Ratio Actual 4,T Ratio No. V V T Tu ft lb lb 4 Vn lb ft lb:ft OT. L1 98-63(1) TP19.071x13.75x0.188 7027.24 409063.00 0.017 716.92 621937.50 0.001 L2 63-30.5(2) TP23.638x18.316x0.188 8328.27 478498.00 0.017 700.60 902833.33 0.001 L3 30.5-0(3) TP27.9x22.731x0.25 9544.52 739971.00 0.013 697.40 1683000.00 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. Pu M x M,„ Vu T Stress Stress ft vi,„ itMz oM„v 4„Vn 4,,,Tn Ratio Ratio Ll 98-63(1) 0.004 0.683 0.000 0.017 0.001 0.687 1.000 4.8.2 L2 63-30.5(2) 0.006 1.008 0.000 0.017 0.001 1.014 1.000 4.8.2 L3 30.5-0(3) 0.006 0.903 0.000 0.013 0.000 0.910 1.000 4.8.2 � �werJob Page 1-5 & Highway 217 (BU 824674) 13 of 13 Tower Engineering Project Date Professionals TEP No. 37852.122902 11:17:35 06/27/17 326 Tiyon Road Raleigh,NC 27603 Client Designed by Phone:(919)661-6351 Crown Castle FAX: (919)661-6350 TSA Section Capacity Table Section Elevation Component Size Critical P ()Pana„, % Pass No. f Type Element lb lb Capacity Fail L1 98-63 Pole TP19.071x13.75x0.188 1 -3289.95 818126.00 68.7 Pass L2 63-30.5 Pole TP23.638x18.316x0.188 2 -5701.46 956996.00 101.4 Pass' L3 30.5-0 Pole TP27.9x22.731x0.25 3 -9490.24 1479940.00 91.0 Pass Summary Pole(L2) 101.4 Pass' Rating= 101.4 Pass' Notes: 1) A structure rating of 105%or less is within engineering tolerances and considered acceptable. Program Version 7.0.5.1-2/1/2016 File:C:/Users/tsashani/Desktop/In Progress/37852/73647_122902_8246741-5&Highway 217 SA/tnxTower/824674 LC5.eri 201 98-ft Monopole Tower Structural Analysis Report June 27,CCI BU No 824674 7 TEP Project Number 37852.122902, Application 395487, Revision 0 Page 7 APPENDIX B BASE LEVEL DRAWING tnxTower Report-version 7.0.5.1 ' l AI 48 g I - (PROPOSED) / (1) 1-3/5" TO 98 FT LEVEL .." N Q (INSTALLED) / / " • (1) 5/16" TO 98 FT LEVEL / / \ %. (16) 7/8" TO 98 FT LEVEL ••• I 1 Q4 Q1 1 • • Q3 Q2 / 1 6 ' (INSTALLED) (1) 1/2" TO 101 FT TOWER LIGHTING \ / / \ N -..... ,,.- � \ / i • CLIMBING PEGS W/ SAFETY CLIMB BUSINESS UNIT: 824674 TOWER ID: C_BASELEVEL ,2017 98-ft Monopole Tower Structural Analysis Report CC/BJuneU No27824674 TEP Project Number 37852.122902,Application 395487, Revision 0 Page 8 APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report-version 7.0.5.1 Square, Stiffened / Unstiffened Base Plate, Any Rod Material - Rev. F /G Assumptions: 1)Rod groups at corners. Total#rods divisible by 4. Maximum total#of rods=48(12 per Corner). 2)Rod Spacing=Straight Center-to-Center distance between any(2)adjacent rods(same corner) 3)Clear space between bottom of leveling nut and top of concrete not exceeding(1)*(Rod Diameter) Site Data Base Reactions BU#: 824674 TIA Revision: G Site Name: 1-5&Highway 217 Factored Moment,Mu: 759 ft-kips App#: 395487, Rev. 0 Factored Axial, Pu: 10 kips Anchor Rod Data Factored Shear,Vu: 10 kips Eta Factor, r) 0.5 TIA G(Fig.4-4) Qty: 8 Diam: 2.25 in Anchor Rod Results Rod Material: A615-J' : TIA G-->Max Rod(Cu+Vu/r)): 133.7 Kips Yield, Fy: 75 ksi Axial Design Strength, cD*Fu*Anet: 260.0 Kips Strength, Fu: 100 ksi Anchor Rod Stress Ratio: 51.4% Pass Bolt Circle: 35 in Anchor Spacing: 6 in Plate Data Base Plate Results Flexural Check PL Ref. Data W=Side: 34 in Base Plate Stress: 33.4 ksi Yield Line(in): Thick: 2.25 in PL Design Bending Strength, cD*Fy: 45.0 ksi 20.18 Grade: 50 ksi Base Plate Stress Ratio: 74.1% Pass Max PL Length: Clip Distance: 0 ; in 20.18 N/A-Unstiffened Stiffener Data(Welding at both sides) Stiffener Results Configuration: Unstiffened Horizontal Weld : N/A Weld Type: ** Vertical Weld: N/A Groove Depth: <--Disregard Plate Flex+Shear,fb/Fb+(fv/Fv)^2: N/A Groove Angle: <--Disregard Plate Tension+Shear,ft/Ft+(fv/Fv)^2: N/A - Fillet H.Weld: in Plate Comp. (AISC Bracket): N/A - Fillet V.Weld: in Pole Results Width: in Pole Punching Shear Check: N/A Height: in Thick: in Max PL Length Notch: in eld Line Grade: ksi # Anehcrs� Weld str.: ksi at corner= �5t St = BASE PL OB/4I; I,� A � THICKNESS �� tAOGhOr, Typ. f je>------ ' STIFFENED CONFeCURATION Q / ° ASSUMED IN TOOL / \\ B.c. Pole Data { /:1/ 1• I� Diam: 27.9 in / t•, // i I Thick: 0.25 in ,.‘,-\c-',//., / f ;' // Input fa:ear Sure �. at B C for Single Grade: 60 ksi // Anchor- Lose #of Sides: 18 °0"IF Round � '�' o � I -7, Pole w/ O F DIAM = D I hs I I Anchor SpacIng Same As S+,ffee :pacing, V/ �1 -1, Except for SI ale Corner iAnchor (Input Clear Spacer **Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CCIplate v2.0 Analysis Date: 6/27/2017 T O W E PASS PASS I-5&Highway 217(BU 824674) ENG NEERING PROFESSIONALS Results Summary: LC1 LC2 TEP#: 37852.122902 Soil Interaction: N/A N/A Analysis: TDV 6/27/2017 Drilled Caisson Tool-Input Foundation Structural: 49.3% 6.9% Check: TSA 6/27/2017 Code Revisions: : Tower Type:14L-t,1-1,,,L0 LC1 LC2 Shaft Information Moment: kip-ft Diameter: ft Axial(download):a kip Projection: ft Shear: kip Caisson Length: ft Axial(uplift): kip f'c: s ksi Max EC: 0.003 in/in Cage 1 Reinforcement Tie Bar Size: (fy=60.0 ksi) Clear Cover to Tie: in(Cage 0=42.00m) Tie Bar Spacing:,2,1,7,:c in Vertical Bar Size:' Vertical Bar Quantity: (p=0.983%) fy: a ksi E: € ksi COPIF: NE R ER 1-5&Highway 217(BU 824674) PRo�so� TEP#: 37852.122902 Analysis: TDV 6/27/2017 Reinforcement Capacity Check: TSA 6/27/2017 2.5 • • 1.5 - • • • 1.0 - 0.5 - • • 0.0 - -2.5 -2,0 -1.5 -1.0 -0.5 0 0 0.5 1.0 1.5 0 2 5 • • -0.5 • -1.0 - • • -1.5 - • • 2.5 LC1 LC2 Vu= 9.5 9.5 kip Vc= 229.5 230.3 kip fy,tie= a r Vs= 48.9 48.9 kip 4Vn= 208.8 209.4 kip Capacity= 4.6% 4.6% PASS PASS LC1 LC2 Mu= 759.4 107.6 kip-ft 4Mn= 1540.2 1558.3 kip-ft Capacity= 49.3% 6.9% PASS PASS I M 1 1 I I I 1 I f I I I • Pad& Pier Monopole Foundation with Piles Site Name: 1-5 &Highway 217 Site Number: BU 824674 TEP#: 37852.122902 Calcs By: TDV Date: 6/27/2017 Checked By: TSA Date: 6/27/2017 Pad Structural Check Pier Shape= Round DPIEP.-..... 1 DPIER= 4 ft ( As In^2 LPIER= 3 ft ( /ft) 0.527 tPAD= 2 ft PIER Fy(ksi) 60 DPILE= 1 ft f —, — — b(in) 12 Loc= 9 ft A • d (in) 21 tP�n Fc(ksi) 4 LPAD= 10.5 ft A _ n= 4 <__#Piles ' r `^I length pier to piles (ft) 2.5 Pile Capacity= 97.5 k Force in pile(Kip) 84.1 DP1LE->-4 p= P(unfactored)= 7.92 k .-_._ _i_nc—_ a 9.3 , c 0.387 M+(V*(tpad+Lpier))= 807,01 k-ft —_.__.__.._Lr'an Moment(K*ft)/ft 40.1 0.9*Mn (K*ft)/ft 48.9 Lpier above grade= 1 ft WCONC= 46.5 k Soil Unit Wt= 115 psf %Capacity . li,, Wsoil= 27.0 k WCONC uplift= 34.9 k FP=WCONC+Wsoil+P Wsoil uplift= 20.2 k Pile to Pad Connection FP= 82.9 k FP uplift= 62.2 k Bar size 5 R= P/n±M/V2*Loc Number of Bars 4 Fy(ksi) 60 Area of Bar 0.31 Tension= 47.9 k Compression= 84.1 k Tension= 66.96 a Capacity= 4 , Capacity 444441-1- I 6/21/2017 Design Maps Summary ReportGS Design Maps Summary Report User-Specified Input Report Title 7 Wed8246lune4 21,2017 18:54:40 UTC Building Code Reference Docu• ment 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 45.41983°N, 122.74576°W Site Soil Classification Site Class D — "Stiff Soil" I Risk Category /II /II I a ,:i-: .;:,;"-,.**''' ,. ,...'":-,,::::-:-',-, .. ,•`--of VI kot-,i07:60,* Iti '*.::'. ,..,;.. ' :.: 0.- ,'' '- i." .'4',,ii*ii'-gloc4 44,41N 1 - 1 4"' .,,,-.*-1, s,...,..,,..— ,A4r, ,' , ,•••' _, ..x� "'LII '� " � Y Ln ...;... °;'.... :::1..:::Ir'',-.•';4-'*.::;'J.-.. '-'*+*:::#'.-(r.4' por 7,.. .,4 „„,-- ..:ii --- ::::- ' •-.,'Atioie ,..1": -',' ,1-.'f' 4., liit ' . 4 4i,,..1,-e . ' .--1. n .�' d �s - 1- g. ;:,:. „ . -,:e. ..11-40.„.., _., ,... wk. -, .., r -USGS-Provided Output SS = 0.974 g SMS = 1.082 g Sos = 0.721 g S1 = 0.422 g SMl = 0.665 g SD1 = 0.444 g For information on how the SS and Si values above have been calculated from probabilistic (risk-tathrgeted) and deterministic ground motions in the direction of maximum horizontal response, please return to e application and select the"2009 NEHRP"building code reference document. Response Spectrum Lesegn ReSP42r1Se Sptrurr, la a 1172 1. lei sm a £1 • Q f g+ +a.48 sn �` , yea f !a s] a 114 X515 Ca.,I £1'114 Y C>.177 112] .140rar,,q !:..£43 100 1110 f.SOt.r�1 1.53 ..iia >1�:ka ra, a4,3 !.'!..:X3 Ea+'s ;,!aa T:.'�a 1. 7 '.f.3 la]ft,noci.I(sec.j PSCIOd T(sic) •Although this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or implied,as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. https://earthquake.usgs.gov/designmaps/us/summary.php?tem plate=minimal&latitude=45.4198258,1ongiiude=-122.745761111111&siteclass=3&riskcategory=08,e... 1/1