Specifications (44) S raL00 G&/�' 11-7" 5`)//. RECEIVED OFFICE COPY OCT 26 2017 CITY OF TIGARD STRUCTURAL CALCULATIONTL 'DING } FOR RESIDENCE REMODEL 12723 SW SORREL DOCK COURT TIGARD, OR 97223 _AO PROFFs�� • 12, 110 1111 •-E •N �0 ✓G/Y 15 ‘,11'n' yN e. Novo I EXPIRES:12/31/16 Contents Notes Ni Detail A Dl Contact Person: John E Nordling,PE Calculations Cl -C2 NORDLING Proj. No.: 17-288 A STRUCTURAL RESIDENCE SORREL DOCK ENGINEERS, LLC H.E.L.P.GROUP INC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:OCT 2017 By:JEN Sheet No.:COVER • :•• • The existing residence remodel from a structural standpoint consists of the removal of two interior bearing walls between the first and second floors. New beams,support columns and footings will be added. As is typical with all remodels,field discrepancies may be present which may not be apparent prior to demolition/construction. During construction any questionable as-built framing or discrepancies to noted details i to be brought to the attention of the engineer for review and modification will be made if/as required. All construction is to conform to local code requirements. Use Simpson hardware. Provide multiple studs/posts under beams and verify alignment to solid beam/foundations below. Verify that the existing support grade is in good condition suitable for foundation support with a minimum bearing pressure of 1500 psf. If questionable soils are encountered, consult with a geotechnical engineer. Verify that all construction is properly protected and sealed against water penetration. Conform to appropriate code and industry/construction methods. Co-ordinate all structural framing and connections with the existing conditions in regards to alignments,elevation ties with existing framing,etc. Report any conflicts to the engineer prior to construction. Shore the existing framing as required until all new construction is in place and secure. 1. Existing 2 x 10 at 10 inches on center second floor joists eld veri 2. New 3.5 x 9.25 parallam beam(8'-6"maximum span opening. cate beam either under the existing floor joists or cut and hang the floor joists from the side of the beam. If under,connect the existing floor joists to the beam with (2)-10d toe-nails from each side. If hung,use Simpson"LUS410"hangers. 3. Provide multiple studs or 4x post under new beam and secure with stud or blocking each side nailed to the beam. 4. Align 4 x 4 post from crawl space footing to first floor and from first floor to second floor beam(note 1). Provide Simpson"BC40"at first floor, • Simpson"EPC4Z"at new beam. Footing to be l'-9"x l'-9"x 10" with(3)-#4 x 1'-3"each way,3 inches clear of bottom of footing. Connect 4 x 4 post in crawl space to new footing with Simpson"ABA44Z". • • PRop4r Neo 11.7 12,187 r•-- 1 • G., vo 5. 1No \-\- EXPIRES:12/31/16 • NORDLING Proj. No.: 17-288 77 I STRUCTURAL RESIDENCE 111 SORREL DOCK ENGINEERS, LLC H.E.L.P.GROUP INC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:OCT 2017 By:JEN Sheet No.: Ni I • . {610 00DH MI 040. VI -�� 1!,'.g" ` y : oo is ee < d a \\,....„...._... ...7"— ( sae a 21,, �- _ ^ee{ t•1 MEW liy 13 16'-13/4" --e- t6 — rfull6,-1"1 i MA 61',12;7.5• ..1 remAe —r UIP --c / zee, r 12•.10" {, yt_-1V-1—„ x v En N 1'-4" Cr) 1 uee ,,-4"—e^ J ! 1 4, 13,.1 Ar �J k F PROPOSED r .....N 1 4 . _,,,-,-,• -,___L4 ``. 4'-4 1/2"ietvr I a er:- !..."--- ; /' 1.r,, MD GARAGE "">`" 21'1"X 6'-3" , 0PRO4if 12,18 p �l 0 J` G . A} • pyN E. NORo\'\� ' • ( EXPIRES:12/31/16 NORDLING Proj. No.: 17-288 k STRUCTURAL . RESIDENCE SORREL DOCK ,;. ENGINEERS, LLC H.E.L.P.GROUP INC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:OCT 2017 By:JEN Sheet No.: D1 -.. .... .6 .0.. S. .0. ........—F..." --,.. I K7 ...... -.-, 1 6 kir..1 5. 1 ,r,_ 16:HIsm. remels!howl if, — A : —1;ESt IP; °S.* . VII tOtIS rjiM 203. • I • ,-- . 14,1 6'-1 ---1, _ ...„.,_ 1. 1. cr-1-07 • 1 I • t) 2260 . . .......--*„. I UP i 7- I r, I cti r-q" , t51.-4. a . . Z; • . • 12-10 A .1, 4 us"-.7" i•Y--T-4" ' • . • 1 r- 2LGA • • t ' T-6"„,.(4‘. 15'-gl" --0 r to k A f.. PROPOSTD .I. i . ‘..... ... . ., . -4--4'.4 1/2" tj ... ei . . , . , C i 1.4, $ i • • • I ..- •.. .''''Ai. • GARAGE SI. 21-1 X 6-3" • • . . . • . • • . . .. . , . • • NORDLING Proj. No.: 17-288 4 STRUCTURAL SORREL # 4' .,4-t- ENGINEERS, LLC RESIDENCE DOCK;•- H.E.L.P.GROUP INC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:OCT 2017 By:JEN Sheet No.: Pt . .... . . . . . . . , ' " • . . . . . , A S-Atpvt.A, Az•-,6,1t, .•"''' ''' ''''''' ,. •. '' ''' '! ...k...'4,:-":.:-*5`.' ;..1;).,,,-- .3,:c; r •'•t'."-?. ett'':;1'• ... ...... . ... ..., ' r.,‘,..7,,,e1,„(0).,,,..5.07, : ,tei•4` . • CeS.C,ei I. STIFIIN 40-3 318" Tied .a.,, 1 • — --A- ! 1.• z 11$5.10__.I tli1 r.5 4 ., 1 ::'Z. ____a_ II I L_ 1 i 0:41 li ri> , I ,...._ . , .. . \... ,, . . . h „,-.. "----:=1-o vj'''--- — ' UP — •••,.,..., .- ,-k' • 6'-10" WE r 36E t •`',' F•n'-' L 14 I c4 i e e (4:&1 4-=i 1('-.5 ' .. Apr 1 1V6" _ 5, 1 \..../ 7....--i 1 . . .4. ,,„,, ! I - - .7...c. I . I ... - 1 . t•r-tiv=•e-tte, N •••••...••••••••••.••,.• -.-—— 5'-2"---- l't7 - — ) : iT' 5 i N -- 1 •-' i 1-11 1/2" r .... ,.„ ... MOON • 21'-7"X . . . ... '.• . , . , . .. . . ..., , e . . . . • . . , . . i.5 1:14,01ftee, • • -.,,. .. :15ti)21..". /1,,,6'i-e•Y ..,0.vo, . 4,.......,..._................. t PV.f. !..; :.. .. .. .... I 4 ,....•••'.. . -..•''''.....s.,,...„ i ..,.,. ."'....•: "•.•••711••104 ti i'''.. ........ ••. /•?. ft. .-. - ljee".•'>'.. ,-;'-' j p ; , c.„.„.,. -• ... . , ..___ . ,v ,...___ __.... ... -,-z, i , ( • • A. 1 11 if1 ,... 1 . . • . • . • . • . NORDLING . Proj. No.: 17-288 STRUCTURAL ENGINEERS, LLC 171111Z'4 404081V 1111 RESIDENCE SORREL DOCK H.E.L.P.GROUP INC 8775 SW 111th,Suite 200•Beaverton OR,97008 Date:OCT 2017 By:JEN Sheet No.: , h` 40'-3 518" 1 9'-3'118" _ • 9'-'1" _ —9,-8.' w 9'-10" m ... ........ NG, t^ L ATTIC ISTAIRWELL ATTIC � 9 � 3 —}e—5'-10 112" 8 — �'-3 112" { Yr 19'-6 1/2"—gN , r—A, / ats_4Thilli ... a 10._1n are i N47 .. In 1 • NORDLING Proj. No.: 17-288 STRUCTURAL RESIDENCE 5 , SORREL DOCK ;, ENGINEERS, LLC H.E.L.P.GROUP INC 6775 SW 111th,Suite 200.Beaverton OR,97008 Date:OC! 2017 By:JEN Sheet No.: 173 . , A .. ,. . ; . , .. 3 ,c ( rkfr it15). Tilei41:4-. --,--. • ' T-:„7--,L;-;:: :-.,—..........."). : .m7,—,-;t..7.74.7"*1--'1" ' , , , . a '14 fge A 1:1 kr./ IV q; it'!i (y -• . •- .. .. .. 3i1t.;.7 cit. r)L- TAY— ....-'•%... ,,,,,„..,-............--,-----"'"—N,,,,,,....„,.) ... • . . ... . . COT. 1.. -- it et.,40.-s., :.,1? tire, S C c$Yr-i- -6.',L0.,-• -,- k.k ,7 _....i gifC: 6.-1,4P C c, k. c:.„‘. .. ) --,,...----------'-------' ....,---" . , . NORDLING k STRUCTURAL ! LiAJ 1 ENGINEERS, LLC , 11119°V li, prof. No.: 17-288 RESIDENCE SORREL DOCK H.E.L.P.GROUP INC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date:OCT 2017 By:JEN Sheet No.: 61 Nordling Structural Engineers LLC 6775 SW 111th, Suite 200 Beaverton, OR 97008 Date:10125117 Page: MULTI-SPAN TIMBER BEAM DESIGN SORREL DOCK RESIDENCE A-(TL) A-(IL) 8-(TL) B-(LL) GENERAL DATA - 1 2- -4 5- All Spans Simple Support?? : YES Spans Length ft : 8.00 8.00 7.50 7.50 End Fixity: Pin:Pin Pin:Pin Pin:Pin Pin:Pin Beam Width in : 3.500 3.500 3.500 3.500 Beam Depth in : 9.25 9.25 9.25 9.25 CALCULATED VALUES -OK- -OK- -OK- -OK- F'b-Modified Allow. psi : 2990.0 2990.0 2990.0 2990.0 fb-Actual. psi : 1394.5 961.7 1225.6 845.2 F'v-Modified Allow, psi : 304.8 304.8 304.8 304.8 fv(actual)* 1.5 psi : 109.3 75.4 100.8 69.5 Moment @ Left k-in : 0.0 0.0 0.0 0.0 Moment @ Right k-in : 0.0 0.0 0.0 0.0 Max.Mom.@ Mid-Span k-in : 69.6 48.0 61.2 42.2 X-Dist ft : 4.00 4.00 3.75 3.75 Shears: Left k : 2.90 2.00 2.72 1.87 Right k : -2.90 -2.00 -2.72 -1.87 Reaction @ Left DL k : 0.90 0.00 0.84 0.00 LL k : 2.00 2.00 1.87 1.87 Total k : 2.90 2.00 2.72 1.87 Reaction @ Right DL k : 0.90 0.00 0.84 0.00 LI k : 2.00 2.00 1.87 ' 1.87 Total k : 2.90 2.00 2.72 1.87 Max.Deft.@ Mid Span in : -0.152 -0.105 -0.118 -0.081 X-Dist ft : 4.00 4.00 3.75 3.75 DESIGN DATA Le:Unsupported Length ft : 0.00 0.00 0.00 0.00 Fb:Basic Allowable psi : 2600.0 2600.0 2600.0 2600.0 Fv:Basic Allowable psi : 265.0 265.0 265.0 265.0 Elastic Modulus ksi : 1900 1900 1900 1900 Load Duration Factor 1.15 1.15 1.15 1.15 APPLIED LOADS Use Live Load on This Span ? Yes Yes Yes Yes Uniform DL plf : 225.0 0.0 225.0 0.0 LL plf : 500.0 500.0 500.0 500.0 QUERY VALUES Location ft : 0.00 0.00 0.00 0.00 Shear 11 : 2.90 2.00 2.72 1.87 Moment k-in : 0.00 0.00 0.00 0.00 Deflection in : 0.000 0.000 0.000 0.000 V4.4B2 lc)1983.95 ENERCALC Bruce W.Kenny,KW060914SL-A