Plans (73) S 12-cr/2 aif.“ . I 1 5/5 '5 / (d OFFICE COPY F . . ; ,i . Bulletin 110 Rev. W Model G °_ - ' `Automatic Sprinklers '11MIN 1, _.r' > ;w r,� §pa iidy Upright, p$� .S nPy Pendentlia CD C . vni C And Conventional Product Description tt- The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construcif'''''*- tion. The fusible alloy is captured in the cylinder of the ' m solder capsule by a stainless steel ball. When the fusible • 19 alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler.When this happens, ` the lever is released to spring free from the sprinkler so - Ai that all of the operating parts clear from the waterway al- lowing the deflector to distribute the discharging water. T E Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based Upright Pendent alloys for maximum corrosion protection. Lead plated,wax ,1„..„,,,i,,„m,„,,,,,,,,e, coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers ..,v �� are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by mark- ; t ings that appear on several of the operating parts and by an identifying color that appears on the frame. j Sprinkler Types Standard Upright-This deflector configuration is normal- ly used with exposed piping installations. Water is distrib- uted laterally and downward in a wide pattern approximat- ing a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent-This deflector configuration is nor- Application and Installation mally used where the space above the piping is limited Standard sprinklers are used in fixed fire protection sys- or where a concealed piping installation is employed.The tems: Wet, Dry, Deluge or Preaction. Care must be exer- discharge characteristics of the standard pendent are cised that the orifice sizes, temperature ratings, deflector virtually identical to the standard upright as described styles and sprinkler spacings are in accordance with the above. latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. Large and Small Orifice -By varying the orifice size, a The sprinklers must be installed with the Reliable Model large or small orifice sprinkler is created that will distrib- D Sprinkler Wrench. Any other type of wrench may dam- ute as much as 40% more water or 65% less water than age the sprinkler. the normal 1/2" (15mm)orifice sprinkler. The approvals or listings of Reliable Automatic Sprin- klers by major approving organizations are shown in the Conventional -This deflector configuration is used pri- tabulated list provided on the back of this bulletin. marily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceil- ing with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra-high hazard installations. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data "K" Factor Sprinkler Sprinkler Identification Sprinkler Type Height Approvals - Number(SIN) US Metric SSU SSP Standard-Upright(SSU)and Pendent(SSP) Deflectors Marked to Indicate Position '/2"(15 mm)Standard Orifice with 1/2"NPT(R1/z)Thread 5.62 81.0 2'/8"(73 mm) 1,2,3,4,5,6,7 R1025 R1015 '/16"(11 mm)Small Orifice with'/2"NPT(R1/2)Thread 4.24 61.0 2'/e"(73 mm) 1,5 i R1013 3/e"(10 mm)Small Orifice with 1/2"NPT(R'/2)Thread 2.82 40.6 2'/6"(73 mm) 1,2,5 R1021 R1011 5/16"(8 mm)Small Orifice with 1/2"NPT(R1/2)Thread 1.98 28.5 2'/a"(73 mm) 1,5 R1022 R1012 17/32"(20 mm)Large Orifice with 1/2"NPT(R'/2)Thread 7.96 114.7 2'/6"(73 mm) 1,2,5 R1026 R1016 17/32"(20 mm)Large Orifice with 3/4"NPT(R3/4)Thread 8.20 118.2 2 15/16"(75 mm) 1,2,5 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 3,4,5 R1027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 3,4,5 R1024 R1014 Conventional—Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4.10 59.1 73 mm 4 R1074 15mm Standard Orifice with(R'/2) Thread 5.62 81.0 73 mm 3,4,5,7 R1075 20mm XHH with(R3/4)Thread 8.20 118.2 75.4 mm 3,4 R1077 Temperature Ratings sprinklers with soap and water, ammonia or any other clean- Sprinkler Maximum ing fluids. Remove any sprinkler that has been painted (other Ambient Frame 11> lied damaged in anyA stock of Classification Rating applied) or way. spare Temperature Color than factory a sprinklers should be maintained to allow quick replacement of °F °C °F °C damaged or operated sprinklers. Prior to installation, sprinklers Ordinary 135 57 100 38 Black should be maintained in the original cartons and packaging un- Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White til used to minimize the potential for damage to sprinklers that High 286 141 225 107 Blue would cause improper operation or non-operation.Use only the (1)Frame color does not apply to painted or plated sprinklers Model D Sprinkler Wrench for sprinkler removal and installation. -Use sprinkler rating as identified on operating parts. Any other type of wrench may damage the sprinkler. Approval Organizations Finishes(1) 1. Underwriters Laboratories, Inc. and UL Standard Finishes Certified for Canada(cULus). IP.Bronze —All Temperature Ratings 2. Factory Mutual Research Corporation Chrome —All Temperature Ratings 3. Loss Prevention Council White(2) —All Temperature Ratings 4. Pleniere Assemblee Only Frame and Deflector are Painted 5. VdS Schadenverhutung GmbH Special Application Finishes 6. N.Y.C. BS&A No. 587-75—SA or Bright Brass Plated —Only frame,deflector and cap are plated. 135°F(57°C), 165°F N.Y.C. MEA 258-93-E (74°C),212°F(100°C)Temp.Rating. 7. EC Certificate: 1438-CPD-0054(R1015) Black Plated —Only frame,deflector and cap are plated.All Temp.Ratings. Polyester Coated(2)(4) —Only frame and deflector are coated. 1438-CPD-0053(R1025) Lead Plated —165°F(74°C),212°F(100°C)and 286°F(141°C)Temp.Ratings. 1438-CPD-0052(R1075) Wax-Coated(31 —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. 1438-CPD-0056(R1077) Wax-Coated Over Ordering Information Lead Plated(3) —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. Specify (11 Other colors and finishes are available.Consult factory for details. 1. Model G 121 UL listed and NYC MEA Approved only. (3) 212°F(100°C)brown wax may be used on 286°F(141°C) 2. Deflector sprinklers when maximum ambient temperatures do not exceed 150°F • Upright (66°C).UL Listed,FM Approved,NYC MEA 258-93-E. • Pendent 0) FM Approved for R1027 only. • Conventional 3. Nominal Orifice Maintenance 4. Inlet Thread Model G Sprinklers should be inspected and the sprinkler 5. Temperature Rating system maintained in accordance with NFPA 25. Do not clean 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co.,Inc. ® Recycled ® (800)431-1588 Sales Offices Paper Reliabl (800)848 6051 Sales Fax Corporate Offices Revision lines indicate updated or new data. (914)829-2042 www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.04/15 P/N 9999970005 OFFICE COPY Bulletin 014 Rev. P W ® Model F1FR Series "tenable Quick Response 0 Glass Bulb Sprinklersit lo Model Fl FR56 Sprinkler T)rp .' ': . Standard Spray Upright `' �� ` Standard Spray Pendent , ,`; Conventional Upright/Pendent � �(�� IIIM Vertical Sidewall CI fl./ l i-�, Horizontal Sidewall ... Model Fl FR56 RecessedS r pe , Upright Pendent onventional Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types0i _ 1 Standard Spray Pendent ` Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed Pendent/Fl/F2 Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent } Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 �;k s �„`, `air 1,4 Recessed Sprinkler Types a Standard Spray Pendent ' � Model F1 FR56LL&F1 FR42LL Low Lead Spnnlder Recessed Concealed Recessed Types Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead Content Listing &Approvals II The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin PendentF11F2 kler. Product Description 1. Underwriters Laboratories Inc. and Certified for Reliable Model F1FR series sprinklers , Canada(cULus) in accordance with ANSI/UL199. are quick-response automatic sprin- 2. FM Approvals (FM) klers with a glass bulb thermal element. w 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhutung GmbH (VdS) Model F1FR series sprinklers are Stan- 5. Underwriters Laboratories Inc. and Underwriters dard Spray sprinklers, with the excep Laboratories of Canada Certified for Health Effects tion of the Model Fl FR56 Conventional XLH Recessed to NSF/ANSI Standard 61 Annex G (ULH) sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- The Model F1FR Series automatic sprinklers utilize a 3.0 CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) mm frangible glass bulb.These sprinklers have demonstrat- (EC) ed response times in laboratory tests which are five to ten UL Listing Category times faster than standard response sprinklers. This quick Sprinklers,Automatic&Open (VNIV) response enables the Model Fl FR Series sprinklers to apply Quick Response Sprinkler water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 r At normal temperatures, the glass bulb contains the fluid Model F1FR Series sprinklers must be installed with the in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands,forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model Fl FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal Model Fl FR Series Recessed sprinklers are to be installed sidewall, and vertical sidewall deflectors as shown in Fig. 1,Fig.2,or Fig.3,as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model F1FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model Fl FR series sprinkler configurations. Concealed Sprinklers Model F1FR Recessed Pendent and Recessed Horizon- Model F1FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig.5,as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1 FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model Fl FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler. Model Fl and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. the sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons,shown in Fig.2,provide a sprinkler assemblies are completed by the installation of a 1/2-inch(12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1 FR56 Concealed Pendent and Model F1 FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP cov- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm)or 5/8-inch (8mm)of cover cover plate adjustment. In addition,a low profile Model CCP adjustment. Do not install Model Fl FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm)of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm)diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model F1FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed.When inserting or remov- Data Sheets, and the requirements of the Authority Hav- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction.Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is corn- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup.Final adjustment is made Fl FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place.Remove the bulb protector at the time when the sprin plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1 FR56 Concealed Pendent and Model F1 FR56LL of the bulb protector before this time may leave the bulb vul Concealed Pendent sprinklers or the use of the Model CCP nerable to damage.Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with clasp by hand. Do not use tools to remove bulb protectors. which it is not specifically listed my prevent good fire pro tection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity:Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Sprinkler Listings K-factor Deflector/ Installation Approval Model Diameter Orientation Height Wrench SIN and Notes Approvals US Metric inches mm inches mm Pendent 2.25 57 Dor W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D or W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 Dor W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D or W2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 Dor W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D or W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 Dor W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 Dor W2 RA1423 cULus 1,2 Pendent 2.25 57 Dor W2 RA1414 cULus,FM, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, 1,2,3,4 LPCB,VdS,EC F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D or W2 RA1425 cULus,FM, 1,2,3,4 LPCB,VdS, EC "Conventional 2.25 57 Dor W2 RA1475 LPCB,VdS, EC 4 (Pendent or Upright)" Pendent 2.25 57 Dor W2 RA1415 cULus, ULH 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 Dor W2 RA1435 cULus,FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus,FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall 2 25 57 Dor W2 RA1485 cULus,FM, 1,2,3,9 (Pendent or Upright) LPCB (I)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4>Available with LPCB and VdS approved Polyester coating. (5>VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (7)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only.FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches(102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification 100°F(38°C)Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C)Max. Model Deflector/ Temp. Ambient Temp. Orientation 135°F(57°C) 155°F(68°C 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp. Rating i Temp.Rating Temp. Rating Temp. Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus -- Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus, ULH -- Recessed Pendent -- cULus, ULH -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- Upright cULus Pendent cULus,FM, LPCB,VdS,EC Recessed Pendent cULus,FM,LPCB,VdS,EC -- F1FR56 Concealed Pendent" cULus cULus,VdS,EC cULus -- Upright cULus,FM,LPCB,VdS, EC "Conventional LPCB,VdS,EC (Pendent or Upright)" Pendent -- cULus,ULH -- F1FR56LL Recessed Pendent -- cULus,ULH -- Concealed Pendent* -- cULus,ULH -- Horizontal Sidewall cULus,FM F1FR56 Recessed Horizontal cULus, FM Sidewall F1FR56 Vertical Sidewall(Pen cULus, FM, LPCB dent or Upright) " Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F(74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus,ULH cULus, ULH cULus,ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB,VdS, cULus,FM,LPCB, cULus,VdS,EC RA1414 EC VdS, EC F1FR56LL Recessed Pendent cULus,ULH cULus, ULH cULus,ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 2 1/4"HOLE DIA. [57.2mm] 1 15/16"DIA [49.2m,-J / 1" X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER I WRENCH BOSS \ \ / FACE OFFITTING TO FACE OF CEILING DIMENSION II \ I / II F1 ESCUTCHEON - AT MAXIMUM RECESS = 1[25.4mm] T��\�� ,L J II AT MINIMUMM RECESS = 3/8'[9.Smm] F1 ESCUTCHEON 072 F2 ESCUTCHEON 3/4'[l9mm] I` /AT MAXIMUM RECESS = 3/4[19mm] ADJUSTMENT AT MINIMUM RECESS = 3/8[9.5mm] F2 ESCUTCHEON /III ®osvu 1/2—12.7mm] O s !r'1 ! III /�////� ADJUSTMENT !il F) ESCUTCHEON II I Vs" AT MAXIMUM RECESS = 7/8[22.2mm] O11 I�� .2mr /AT MINIMUM RECESS = 1-5/8[41.3mm] 1 [3.2mm] F2 ESCUTCHEON ,i LI q AT MAXIMUM RECESS = 1-1/8[28.6mm] �� AT MINIMUM RECESS = 1-5/8[41.3mm] 2 27/32"DIA. [72.2mm] Hg. 1 Model F1FR56,F1FR56LL,F1FR42,F1 FR40,F1FR42LL,F1FRXLH&F1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon L _ -I I- r=-_=-= FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON j/ A AT MAXIMUM RECESS = 1725.4mm] AT MINIMUM RECESS = 3/8 79.5mm] 4Fl ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8"[34.9mm] AT MAXIMUM RECESS = 3/4"[19mmJ AT MINIMUM RECESS = 2-1/16"[52.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8 741.3mm] 2 1/4" HOLE DIA. -•.-1/8" AT MINIMUM RECESS = 2-1/16752.4mm] [57.2mm] . [3.2mm] 1" X 1/2" REDUCER --- ' -- 'kI Y wxy '` r,NI (1) ' )11111111', i II. � � 4"-12" 1 15/16"" DIA.'ku 11ill i�����iJI� ��II [ ] >_�___ 101.6mm-304.Smm [49.2mmJ wu I IiI -:y, 2 27/32" DIA. inii r ' III!il!IIIII� / CEILING TO 11 ` iiLi ��,J [72.2mm] DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST WRENCH BOSS.SPRINKLER `\ Fl ESCUTCHEON 3/4719mm] ADJUSTMENT f F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 013FWJE RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW _I_ - 2 5/8" DIA. 2 5/16" DIA — HOLE IN CEILING CUP Illy"-- -— /-/- --/7-;7-/i ; 1 1/2" MAX. ,;;;;;;� 1101-1:9-111111111;; ' ////1///A ���� "j, FACE OF FITTING "" "' TO FACE OF CEILING �£_-If a I p I�� DIMENSION CEILING—/ - +� ,;\ a 1 iiiiiiil i i =; gy p.,.,_� 1/2" MAX. == 15/16" COVER ADJUSTMENT COVER PLATE [ ASSEMBLY /3 5/16" DIA. SPRINKLER / CONCEALED, 1/2" ADJUSTMENT 017FG01A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. 1" x 1/2" REDUCING TEE OR ELBOW 1.1,11 If -- -------+F - - - -+--- - 4+ --- - 11 — — �---, 1 r-, 2 5/8" DIA. 2 5/16" 0/A — ' - = , HOLE IN CEILING L J CUP IIMi ice'_-' 1 1/2'k' MAX. FACE 0 Vd I FACE OF FITTING IIIA - SII ////47,;;;;;z1 """ ���jl 0 j�l TO FACE OF CEILING ../..,1 ., I....... DIMENSION CEILING -- .,0.111 064.e .... 5/16" MAX. —I 3/4" COVER ADJUSTMENT COVER PLATE } ASSEMBLY 5/16" DIA. SPRINKLER CONCEALED, 5/16" ADJUSTMENT o17Fco2A Fig.5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch(8.0mm)adjustment-Model CCP cover plate Maintenance Material Data The Model F1 FR Series sprinklers should be inspected and Frame: DZR Brass,QM Brass,or Low Lead Brass the sprinkler system maintained in accordance with NFPA 25.Do not clean sprinklers with soap and water,ammonia or Deflector: CDA Alloy 220,260,or 510 any other cleaning fluids. Remove dust by using a soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming. Replace any sprinkler which has been Cup: CDA Alloy 651 or 693 painted(other than factory applied)or damaged in any way. Washer: Nickel Alloy 440 or 360,coated with PTFE A stock of spare sprinklers should be maintained to allow Adhesive Tape quick replacement of damaged or operated sprinklers. Bulb: Glass Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate) Ordering Information —0. Bronze Brass Chrome Specify: Chrome Plated Chrome White 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Polyester Plated F1 FR42LL F1 FRXLH F1 FR56 F1 FR56LL Coated 141151161 White Painted [ ][ ][ ][ ] Special Application Finishes 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Sprinkler Escutcheon Cover platet1t Pendent][Upright][Conventional][Horizontal Sidewall] Electroless Nickel Electroless Nickel Brass Bright [Recessed Horizontal Sidewall Vertical Sidewall] PTFE>'> PTFE g Sidewall][Vertical Bright Brass(3) Bright Brass Black Plating 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Black Plated Black Plated Black Paint 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Black Paint(2116) Black Paint Off White68°C 175°F 79°C 200°F 93°C 286°F(141°C)] Off White'2>161 Off White Satin Chrome ( k[ ( )][ ( )][ ( )] Chrome Dull Chrome Dull 5. Sprinkler Finish (1)Other finishes and colors are available on special order. Consult the 6. Escutcheon Model: [F1][F2][FP] factory for details.Custom color painted sprinklers may not retain their 7. Escutcheon Finish (where applicable) UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, 8. Cover plate Model: [standard profile CCP 1/2-inch unless specified otherwise. (12.7mm) adjustment][low profile CCP 5/16-inch (2) cULus Listed only. (3) 200°F(93°C)maximum. (8.0mm) adjustment] (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 9. Cover plate Temperature Rating: [135°F(57°C)for use (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and with Ordinary Temperature sprinklers][165°F (74°C) RA1415 (Pendent) in standard black or white. Corrosion resistance in for use with Intermediate Temperature sprinklers] other polyester colors is available upon request. 151 FM Approvals finish as"Polyester coated"applies to SIN Number 10. Cover plate Finish RA1414,RA1435 and RA1425 in standard black or white. 161 LPCB and VdS Approved finish applies only to RA1425,RA1414,RA1418 Note: When Model Fl FR Series Recessed sprinklers are ordered, the (VdS)and RA1475. sprinklers and escutcheons are packaged separately. 171 cULus listed Corrosion Resistant 7. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. 4% Recycled Reobid (800)431 1588Sales Offices Paper ' (800)848-5051 Sales Fax Revision lines indicate updated or new data. (914)829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in u S.A.03/17 P/N 9999970300