Permit (91) zi CITY OF TIGARD MECHANICAL PERMIT a ' COMMUNITY DEVELOPMENTih Permit#: MEC2017-00888 TE GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/09/2017 Parcel: 2S115AB00200 Jurisdiction: Tigard Site address: 16100 SW 113TH AVE Project: Woodspring Apartments Subdivision: WILLOW-BROOK-FARM Lot: 25 Project Description: Gas furnace replacement for office. Contractor: SPECIALTY HEATING&COOLING INC Owner: ED ENVIRONS WOODSPRING LLC ET AL 7500 SW TECH CENTER DR STE 130 BY HAMILTON, ZANZE&COMPANY TIGARD, OR 97223 THE PRESIDIO OF SAN FRANCISCO 37 GRAHAM ST STE 200B SAN FRANCISCO, CA 94129 PHONE: 503-620-5643 PHONE: FAX: 503-681-0793 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 11/09/2017 $182.65 Class of Work: ALT Type of Const: Plan Review 11/09/2017 $45.66 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 11/09/2017 $21.92 Stories: Info Process/Archiving-Sm$0.50(up to 11/09/2017 $1.50 Project Valuation: $4,200.00 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units<10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 1 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $251.73 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth i DAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 , .800.332.2344'. �A` Issued By: Permittee Signature: ?' it Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONLY City g C* .1 Received 1.< - of Tigard fi Permit No.: I.Ill 13125 SW Hall Blvd.,Tigard,OR 97223 y Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: T I G A R D Inspection Line: 503.639.4175 Date Ready/By: ® See Page 2 for Internet: www.tigard-or.govt T -, RDNotified/Method: Illigil Supplemental Information 3UILD NNNG ritVISION TYPE OF WORK COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ 41 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT J SYSTEMS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: A/b/OC) 6/ C/ SIA) /13 Ar ir conditioning 46.75 Job site address: OC'S. Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Z Qvd e/ l' 7 74/ Furnace 100,000+BTU(ducts/vents) 54.91 v✓ �L Heat pump _ 61.06 Suite/bldg./apt.no.: Project name:1)c d 11Y7 7 ��@21C, '7 Duct work 23.32 Cross street/directions to job site: V Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF:WORK Gas fireplace/insert 33.39 /� Gy Flue vent for water heater or gas XP/ll)« D O? Q`$' �UIf-tioce L /r 977j fireplace 23.32 n (/Cf Log lighter(gas) 23.32 q6,_S' -iiiP�Ei L {4i.e- Ci L .. Wood/pellet stove 33.39 (� Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ISL—PROPERTY OWNER 0 TENANT Other: 23.32 Environmental exhaust and ventilation: Name: Leiepepe:P�gdJI/ trbAiRJ Range hood/other kitchen /1/ © equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: /./(,aVd/ ®lpr 970707/7 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(fe, ) 63? 7W 9' Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT ®i CONTACT PERSON Other: 23.32 Business name:Specialty Heating&Cooling Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Jeff Schwab Furnace,etc. Address:7500 SW Tech Center Dr Gas heat pump Wall/suspended/unit heater City/State/ZIP:Tigard,Or.97223 Water heater Phone:(503)616-0773 Fax: :( ) Fireplace Range E-mail:jeffs@specialtyheating.com Barbecue CONTRACTOR Clothes dryer(gas) I Business name:Specialty Heating&Cooling Other: MECHANICAL PERMIT FEES* Address:7500 SW Tech Center Dr Subtotal City/State/ZIP:Tigard,Or.97223 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503)616-0773 Fax:( ) State surcharge(12%of permit fee) CCB lic.:66578 TOTAL PERMIT FEE 7//1/ This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: / * Fee methodology set by Tri-County Building Industry Service Board -+ /, Print name: J �c-it 4, Date:Date: ///q4 7 I:ABuilding\Permits\MEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Family Fee Schedule: Total Valuation: Permit Fee: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 16100 SW 113TH AVE, TIGARD, OR, 97224 November 21 , 2017 at 10:22:48 AM Record Type: Record ID: Commercial - Mechanical MEC2017-00888 Inspection Type: Inspector: 699 Mechanical final Chip Barnett Result: PASS - NoCofO Comments: Minor Label #ELS616268 Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 16100 SW 113TH AVE, TIGARD, OR, 97224 November 21 , 2017 at 10:22:48 AM Record Type: Record ID: Commercial - Mechanical MEC2017-00888 Inspection Type: Inspector: 699 Mechanical final Chip Barnett Result: PASS - NoCofO Comments: Minor Label #ELS616268 Violation Summary: Inspector Contractor