Report (42) NFPA 72, Chapter 4-Central Station
The Prime Contractor:.
Central Station Location:
Means of transmission of signals from the protected premise to the central station:
McCulloh Multiplex
Digital Alarm Communicator One-Way Radio
Two-Way Radio Others
Means of transmission of alarms to the public fire service communications center:
1.
2.
System Location:
Organization Name/Phone Representative Name/Phone
Installer Frahler Electric
Supplier
Service Organization Siemens
Moses Frangopolous
503-207-1900
Location of Record (As-Built) Drawings:
On Site
Location of Owners Manuals:
On Site
Location of Test Reports:
A contract, dated N/A for test and inspection in accordance with NFPA standard(s)
No.(s) dated
is in effect.
2. Certification of System Installation
This system has been installed in accordance with the NFPA standards as listed below, was
inspected by Frahler Electric
on 10-31-17 , includes the devices
listed below and has been in service since 10-31-17
X NFPA 72, Chapters 4 _ 5 6 _ 7 _ 10
X NFPA 70, National Electrical Code,Article 760
X Manufacturer's Instructions
Oth (specify):
Signed:
Date:10-31-17
Organization:Frahler Electric
Updated: 10/3/2013
Page 2
3. Certification of System Operation
All operational features and functions of this partial system were tested by Siemens Industry Inc.
on 10-31-17 and found to be operating properly
requirements of: p g pro erl in accordance with the
x NFPA 72, Chapters _ 4 _ 56 _ 7 10
x NFPA 70, National Electrical Code,Article 760
x Manufacturer's Instructions
Other(specify):
Signed:
Date:10-31-17
Organization:Siemens Industry Inc.
4. Alarm Initiating Devices and Circuits
MANUAL
a) Manual Stations BG—CHEMICAL
b) Combination Manual Fire Alarm and Guard's Tour Coded Stat onsers Coded
AUTOMATIC
Coverage: Complete YES
a) Smoke Detectors: Ion Photo
b) Duct Detectors: Ion Photo
c) Heat Detectors: FT RR FT/RR
d) Sprinkler Water Flow Switches: Noncoded,Activating RC
e) Other(list): Transmitters Coded
5. Supervisory Signal Initiating Devices and Circuits
GUARD'S TOUR
a) Coded Stations
b) Noncoded Stations Activating Transmitters
c) Compulsory Guard Tour System Comprised of Transmitter Stations
and Intermediate Stations
Note: Combination devices recorded under 4(b)and 5(a).
SPRINKLER SYSTEM
a) Coded Valve Supervisory Signaling Attachments
Valve Supervisory Switches Activating Transmitters
b) Building Temperature Points
c) Site Water Temperature Points
d) Site Water Supply Level Points
Updated: 10/3/2013
Page 3
Electric Fire Pump:
e) Fire Pump Power
f) Fire Pump Running
g) Phase Reversal
Engine-Driven Fire Pump:
h) Selector in Auto Position
i) Engine or Control Panel Trouble
j) Fire Pump Running
Engine-Driven Generator:
k) Selector in Auto Position
I) Control Panel Trouble
m) Transfer Switches
n) Engine Running
Other Supervisory Function(s) (specify):
6. Alarm Notification Appliances and Circuits
Quantity of indicating appliance circuits connected to the system:
Types and quantities of alarm indicating appliances installed:
a) Bells Inch
Speakers
b) Horns
c) Chimes
d) Other:
e) 4 Visual Signals Type:Multi candela speaker strobe
3 with audible w/o audible
f) Local Annunciator
7. Signaling Line Circuits:
Quantity and Style of signaling line circuits connected to system:
Quantity: Style:
8. System Power Supplies
a) Primary(Main): Nominal Voltage: Current Rating:
Overcurrent Protection: Type:
Location: Current Rating:
b) Secondary(Standby):
Storage Battery: Amp-Hour Rating
Calculated capacity to drive system, in hours: 24
Engine-driven generator dedicated to fire alarm system:
Location of fuel storage:
Updated: 10/3/2013
Page 4
c) Emergency or Standby System used as backup to Primary Power Supply, instead of using a
Secondary Power Supply:
0 Emergency System described in NFPA 70,Article 700
0 Legally Required Standby System described in NFPA 70,Article 701
0 Optional Standby System described in NFPA 70,Article 702, which also meets the
performance requirements of Article 700 or 701
9. System Software
a) Operating System Software Revision Level(s):CSGM 18.04
b) Application Software Revision Level(s):See onsite backup
c) Revision Completed by:Sam C. Siemens Industry Inc.
(name) (firm)
10. Comments:
Project Scope—
Add notification appliances per design.Tie into existing strobe and audio circuits.Test during general buiding evac
CorreCorrell Digitally signed by Correll Samuel
ll UN:senalNumber=LOU IKSLS,
givenName=Samuel,sn=Correll,
Samuel o=Siemens,cn=Correll Samuel
nare.2n7 in it II-cc-17-mm. Eng.Spec II 10-31-17
(signed)for Alarm Service Company (title) (date)
Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA
standard(s):
System deviations from the referenced NFPA standard(s)are: None
(signed)for Alarm Service Company (title) (date)
Upon completion of the system(s) satisfactory test(s)witnessed (if required by the authority
having jurisdiction:
(signed) representative of the authority having jurisdiction (title) (date)
Updated: 10/3/2013