Report (42) NFPA 72, Chapter 4-Central Station The Prime Contractor:. Central Station Location: Means of transmission of signals from the protected premise to the central station: McCulloh Multiplex Digital Alarm Communicator One-Way Radio Two-Way Radio Others Means of transmission of alarms to the public fire service communications center: 1. 2. System Location: Organization Name/Phone Representative Name/Phone Installer Frahler Electric Supplier Service Organization Siemens Moses Frangopolous 503-207-1900 Location of Record (As-Built) Drawings: On Site Location of Owners Manuals: On Site Location of Test Reports: A contract, dated N/A for test and inspection in accordance with NFPA standard(s) No.(s) dated is in effect. 2. Certification of System Installation This system has been installed in accordance with the NFPA standards as listed below, was inspected by Frahler Electric on 10-31-17 , includes the devices listed below and has been in service since 10-31-17 X NFPA 72, Chapters 4 _ 5 6 _ 7 _ 10 X NFPA 70, National Electrical Code,Article 760 X Manufacturer's Instructions Oth (specify): Signed: Date:10-31-17 Organization:Frahler Electric Updated: 10/3/2013 Page 2 3. Certification of System Operation All operational features and functions of this partial system were tested by Siemens Industry Inc. on 10-31-17 and found to be operating properly requirements of: p g pro erl in accordance with the x NFPA 72, Chapters _ 4 _ 56 _ 7 10 x NFPA 70, National Electrical Code,Article 760 x Manufacturer's Instructions Other(specify): Signed: Date:10-31-17 Organization:Siemens Industry Inc. 4. Alarm Initiating Devices and Circuits MANUAL a) Manual Stations BG—CHEMICAL b) Combination Manual Fire Alarm and Guard's Tour Coded Stat onsers Coded AUTOMATIC Coverage: Complete YES a) Smoke Detectors: Ion Photo b) Duct Detectors: Ion Photo c) Heat Detectors: FT RR FT/RR d) Sprinkler Water Flow Switches: Noncoded,Activating RC e) Other(list): Transmitters Coded 5. Supervisory Signal Initiating Devices and Circuits GUARD'S TOUR a) Coded Stations b) Noncoded Stations Activating Transmitters c) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations Note: Combination devices recorded under 4(b)and 5(a). SPRINKLER SYSTEM a) Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches Activating Transmitters b) Building Temperature Points c) Site Water Temperature Points d) Site Water Supply Level Points Updated: 10/3/2013 Page 3 Electric Fire Pump: e) Fire Pump Power f) Fire Pump Running g) Phase Reversal Engine-Driven Fire Pump: h) Selector in Auto Position i) Engine or Control Panel Trouble j) Fire Pump Running Engine-Driven Generator: k) Selector in Auto Position I) Control Panel Trouble m) Transfer Switches n) Engine Running Other Supervisory Function(s) (specify): 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: a) Bells Inch Speakers b) Horns c) Chimes d) Other: e) 4 Visual Signals Type:Multi candela speaker strobe 3 with audible w/o audible f) Local Annunciator 7. Signaling Line Circuits: Quantity and Style of signaling line circuits connected to system: Quantity: Style: 8. System Power Supplies a) Primary(Main): Nominal Voltage: Current Rating: Overcurrent Protection: Type: Location: Current Rating: b) Secondary(Standby): Storage Battery: Amp-Hour Rating Calculated capacity to drive system, in hours: 24 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Updated: 10/3/2013 Page 4 c) Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: 0 Emergency System described in NFPA 70,Article 700 0 Legally Required Standby System described in NFPA 70,Article 701 0 Optional Standby System described in NFPA 70,Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software a) Operating System Software Revision Level(s):CSGM 18.04 b) Application Software Revision Level(s):See onsite backup c) Revision Completed by:Sam C. Siemens Industry Inc. (name) (firm) 10. Comments: Project Scope— Add notification appliances per design.Tie into existing strobe and audio circuits.Test during general buiding evac CorreCorrell Digitally signed by Correll Samuel ll UN:senalNumber=LOU IKSLS, givenName=Samuel,sn=Correll, Samuel o=Siemens,cn=Correll Samuel nare.2n7 in it II-cc-17-mm. Eng.Spec II 10-31-17 (signed)for Alarm Service Company (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s)are: None (signed)for Alarm Service Company (title) (date) Upon completion of the system(s) satisfactory test(s)witnessed (if required by the authority having jurisdiction: (signed) representative of the authority having jurisdiction (title) (date) Updated: 10/3/2013 Page 5