Permit (48) � CITY OF TIGARD MECHANICAL PERMIT ''- COMMUNITY DEVELOPMENT Permit#: MEC2017 00626 T i 'AJC D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/31/2017 Parcel: 2S113AB01400 Jurisdiction: Tigard Site address: 7358 SW DURHAM RD Project: Coram Subdivision: None Lot: None Project Description: Mechanical work associated with a clean room renovation,the installation of a negative pressure suite& installation of(2)RTU's. Contractor: DIAMOND CONTRACTORS INC Owner: PACIFIC REALTY ASSOCIATES LP 4224 NE PORT DR ATTN: N PIVEN LEE'S SUMMIT, MO 64064 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 816-650-9200 PHONE: FAX: 816-650-9279 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 10/27/2017 $1,819.38 Class of Work: ALT Type of Const: IIIB Plan Review 10/27/2017 $454.85 12%State Surcharge-Mechanical 1 0/2 712 0 1 7 $218.33 Occupancy Grp: F-1 Occupancy Load: Stories: 4 Info Process/Archiving-Lg$2.00(over 10/27/2017 $92.00 11x17)Valuation: $68,220.00 Info Process/Archiving-Sm$0.50(up to 10/27/2017 $20.00 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: 1 Vent Systems: Total $2,604.56 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: 4 reheat Duct Work: 1 coils, 1 fan Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Pp ermittee Signature: .AIME Wilk/di Call 503.639.4175 by 7:00 a.m.for the next available inspectitQd. -. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. D Mechanical Permit ApplicaitEC � L FOR OFFICE:USE ONLY City of Tigard 1 Received 13125 SW Hall Blvd.,Tigard,OR 97223 !,u G 1 2(i1 i Date/By: gi 7 ilis Permit No.:M tC��7_� Phone: 503.718.2439 Fax: 503.598.1960 / tP Plan Review 7 .1..I C A R i) Inspection Line: 503.639.4175 / 'i e k IA Date/By: r-1 ( lE, t Other_erne /7 M1449-6/'-:,76 see Page 2 for r Internet: www,tigard-or.gov IL. 1 c. tote ed/MothReady/Bo lung: G DIV' Oat iotificd/iMcthod•• 31, 11 � ��2/� �/ //4/111 Supplemental Information TYPE OF'WORK CO1ji, 1:y:CIAL FEES`'SCBEDUM-USE.CHECKLIST o New construction �1 Addition/alteration/replacementippAitr Mechanical permit fees*are based on the value of the work �' performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: „ mechanical materials,equipment,labor overhead,and rf j� 'CA' (ORy'OF-CONSTRUCTIO - , Z. � Value:$ (ie0 1-and 2-family dwelling i:# Commercial/industrial 0 Accessory buildingSWEN'I1A s EQ r 1.,-'t '`7 fIEJ* ❑Multi-family ❑Master builderFor special information use checklist 0 Other: Description 1 Qty, 1 Ea. i Total n -JOB BITE INFORMATION AND LOCATION,. - Heatinglcooling: Job site address: 7358 SW Durham Rd. Air conditioning 46.75 Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Portland, OR 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: I Project name: CVS Coram Portland Renovation Heat pump 61.06 Cross street/directions to job site: SW Upper Boones FerryRd. Duct work 23.32 Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Other: Lot no.: 23.32 Tax map/parcel no.: Other fuel appliances: Water heater 23.32 • DESCRIPTION OF WORK Gas fireplace/insert THIS PROJECT INCLUDES THE RENOVATION OF AN EXISTING fireplace vent for water heater or gas 33.39 CLAN ROOM SUI I E, I HE INS I ALLA!ION OI A NEGA I WE li h 23.32 PRESSURE SUITE AND THE. DITION OF 2 ROOF TOP UNITS. Logd/pelletstov 23.32 TENANT SPACE IS APPROXIMATELY 12,417 SF.AREA OF Wood/pellet fireplace/insert 33.39 ALTERATION IS APPROXIMATELY 1,669 SF. Wood ftrepler/flusert 23.32 Chimney/liner/fiue/vent i 23.32 PROPERTY OWNER I © ITSANT Other: 23.32 ame:CVS/HEALTH, INC. Erik Bracone Range nmentaerkitc stand ventilation: Range hood/other kitchen .4 ddress:4785 Granite Dr. equipment 33.39 ' itylState✓ZIP: Rocklin, CA 95677 Clothes dryer exhaust 33.39 Single-duct exhaust(bathrooms, 'hone:(916)532-1744 toilet co t#artments ut31i rooms 23.32 Fax:( ) Attic/crawl••ace fans 23 32 • s❑APPLICA111'1 j iajCONTSlCT�'PERSON Other: Business name; 23.32 ,'•, GPD Engineering and Architecture Professional Corp. Fuel piping: Contact name:Shawn Finley 514.15 for first four;54.03 for each additional Furnace,etc. Address:520 S. Main Street, Suite 2531 Gas heat purnp ' 'City/State/ZIP: Akron, OH 44311 Wall/suspended/unitheater 11.q Water heater Phone:(614)588 8060 Fax::( ) Fire'lace —_ E-mail: sfinle Range ' y@gpdgroup.com CONTRACTOR Barbecue ,. Clothes dryer(gas) ' s Business name: TED - 1 t\-“10�N INC other: � p c" t � P1�. °4'1* Address:"V ' l V �isiL MECHANICAL Ramat r* City/State/ZIP; Subtotal .,..—.,-t—___ ,,,-a! / ( - r Minimum permit fee($90.00) Phone:($ 1(4) 5--0 Fax: Plan review(25%of permit fee) UC) ( \�) (r,soy CCBIic.: /a to'7 State surcharge(12%ofpermit fee) TOTAL PERMIT FEE jj This permit application expires If a permit is not obtained within 180 Authorized s t>fre: t days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board I Print name: C, # _. � ^ I Date: 1:4 3uildingTermitAMEC_Pe=mBApp_o40113.doe g 'Sjj��ff��. 44 617T 1/07/cOM/WEB) Mechanical Permit Application - City of Tigard Page 2 -Supplemental Information Commercial&Multi-Family Fee Schedule: Total Valuatton: :., PermiitFee•x ,. A, $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $2.54$3e first$10,000.00 and 4foreaor ch additional$0000 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $I00,000.0I and up $2 and 92 for each additional$100 00 o fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Buiiding\Pernuts\MEC PermitAPP_040113.doc 2 /'•I.� GPD GROUP. ArchitectslEngineerslPlanners Glaus,Pyle,Schomer,Burns&DeHaven,Inc. www.gpdgroup.com 1-800-955-4731 LETTER OF TRANSMITTAL REAttAttention Plans Examiner ention 8/14/2017 Job No 2016285.50 Coram Portland Renovations— Bulletin 1 To City of Tigard Permit Center AUG 16 2011 Re drawings 13123 SW Hall Blvd. -. TY OF TIGARD Tigard, OR 97223 tit TIMING DIVISION WE ARE SENDING YOU ❑ Attached 0 Under separate cover via the following items: ❑ Shop drawings 0 Prints ® Plans El Samples 0 Specifications ❑ Copy of letter 0 Change order 0 Sepias 0 COPIES DATE NO. DESCRIPTION 2 08-11-17 Coram Portland Renovations drawings—Bulletin 1 —wet sealed 1 08-14-17 Tigard MEP permit app- signed 2 cut sheet RTU-1 2 cut sheet RTU-2 2 Calcs - Portland Seismic Anchorage Analysis-Stamped THESE ARE TRANSMITTED as checked below: ❑ For compliance 0 Approved ❑ Submit copies for distribution For your use El Approved as noted ❑ Return corrected documents El As requested El Revise&resubmit 0 PRINTS RETURNED AFTER LOAN TO US ❑ For review and comment 0 Rejected ❑ ❑ FOR BIDS DUE REMARKS: Please accept this application for MEP permit and review at your earliest convenience. Feel free to contact me at any time with questions—614-588-8060/sfinlevCc�gpdgroup.com. Thank you. Sincerely, Shawn Finley GPD Group/1801 Watermark Drive,Suite 210 Columbus,Ohio 43215/ph:614.588.8060 Copy to file Signed If enclosures are not as noted,kindly notify us at once. AKRON I ATLANTA I CLEVELAND I COLUMBUS I INDIANAPOLIS I MARION I PHOENIX I SEATTLE I YOUNGSTOWN City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7358 SW DURHAM RD, TIGARD, OR, 97224 January 31 , 2018 at 10:20:14 AM Record Type: Record ID: Commercial - Mechanical MEC2017-00626 Inspection Type: Inspector: 699 Mechanical final Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor