Loading...
Plans (65) fill Approved plans MILLER shall be on jo Sit ; a _ CONSULTING ENGINEERS OCT 4 2017 ',,,i'l Yy¢s:, 1 . STRUCTURAL CALCULATIONS `a; 7.1 A:'-' :- Wells Residence Front Shear Wall Analysis 15226SW Greenfield Drive, Tigard, Oregon Exteriors, Inc. September 27, 2017 Project No. 171116 12 pages OFFICE COPY Principal Checked: )441 CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: OTC: [ I C. -` 1 Permit#: MS-fra_O 1-7" 0 0 3-7 4- ,,,.` `'=Address. ) ^, r rt ,,r,•_il r ! � l ,j ti FL,sPIE 33333 Date: lo-l,p —1-1 { r! (nit=GON , , F nr. LX! 7liVI i> al cat`s *** LIMITATIONS *** Miller Consulting Engineers, Inc. was retained in a limited capacity this project. This design is based upon information provided byte client, who is solely responsible for accuracy of same. No responsibility and or liability is assumed by or is to be assigned to the engineer for items beyond that shown on these sheets. Engineering Practical,Diverse Structural Solutions Since 1978 9570 S W Barbur Blvd.,Suite 100, Portland,Oregon 97219-5412 Phone:(503)246-1250 Fax:(503)246-1395 www.miller-se.corn Building Code: 2014 Oregon Structural Specialty Code Soils Report: No Soils Report by: N/A Dated: N/A Soil Bearing: 1500 PSF Retaining Walls: No Equivalent Fluid Pressure(active): N/A PCF Passive bearing: N/A PCF Friction: N/A Structural System: Building Structure Vertical System:Wood framed Construction Lateral Sys: Flexible Diaphragm/Wood shearwalls Element Roof Floor Corridor Garage Load Type Dead Dead Dead Dead Basic Design Value(PSF) 15 15 15 10 Loads: Load Type Snow Floor Live Corridor Live Deck Live Value(PSF) 25 40 100 40 Deflection Criteria U240 U360 U360 U360 Lateral Design Parameters: Wind Design:ASCE 7-10 Wind Speed(3 sec Gust):_ 120 _ MPH Exposure B Importance Factors Iw= 1.00 IE= 1.00 Is= 1.00 I;= 1.00 Risk Cat: II (ice w/wind) (seismic) (snow) (ice) Seismic Design Latitude: 45.460965 Seismic design parameters are based on published Longitude: 122.808690 values from the USGS web site. 2%PE in 50 years,0.2 sec SA=Ss 2%PE in 50 years,1.0 sec SA=SI (Site class B parameters are indicated on this page,for actual site class used in design,refer to seismic design summary) Design Summary: Existing residence. Design shear walls above garage for new window openings.No changes in the profile or plan of the structure. Index of Calculations: Design summary: pages 1-3 Gravity Design: pages 4-5 Lateral Design: pages 6-12 Art 9570 SW Barbar Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred Mi Portland,OR 97219 15226SW Greenfield Drive, Tigard, Location 9 � Oregon Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 1 of 12 www.miller-se.com By Ck'd f-, Date Page ENGINEERS • GRAVITY FRAMING REFERENCE Cul TIN F7eC1S/ING,FIAT,'NG, .11.5tAil 4.r.ID Di HEADERS with axes,S'h'2/ri 4—RIMERS HEADER (CALC ON NEXT PAGE) / IHI _1! 4f 'iI 7 11 !�-1�—+ I. I �__�Y,o OF u I I �� I ! !; 1 III Ii ' ; I }(,u 0 II II „„. +j 1 „,„ I �74n1a I 74 riu i + 2,4.£ra.?fn� 1 — .__ i{ II ' - --- F✓nmi,�y ii ii I + i II `I, � ;r { ._ I . .I t _, N FI€ADFR S d rc,,, . II f I jI + I ' • 1 I i I 1 I � I i /1,)EIISate gW I�F51O(jfF.>ij-F FIssIEId Or SALE %a= l'c' '1,5�ir4 ,OR. o 1'1'i l 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred NS Portland,OR 97219Ilk 15226SW Greenfield Drive,Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 4 of 12 www.miller-se.com By Ck'd 1 Date Page ENGINEERS fai F 0 R T E , MEMBER REPORT Level,HDR PASSED 1 piece(s) 6 x 10 Douglas Fir-Larch No. 2 Overall Length:3'3" + + o 0 III 0 All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. Design Results: _ Actual @ Location; Allowed,; '.' Result,, LDF Load:Combination(Pattern) System:Wall Member Reaction(lbs) 1187 @ 0 5156(1.5(T) Passed(23%) -- 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Header Shear(lbs) 517 @ 11" 6810 Passed(8%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Use:Residential Moment(Ft-lbs) 964 @ 1'7 1/2" 6937 Passed(14%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Code:IBC 2012 Live Load Defl.(in) 0.003 @ 1,7 1/2" 0.108 Passed(L/999+) -- 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology:ASD Total Load Defl.(in) 0.004 @ 1'7 1/2" 0.162 Passed(L/999+) -- 1.0 D+0.75 L+0.75 S(All Spans) • Deflection criteria:LL(L/360)and TL(L/240). •Top Edge Bracing(Lu):Top compression edge must be braced at 3'3"o/c unless detailed otherwise. •Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 3'3"o/c unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports(lbs) Supports Total Available Required Dead Floor Snow Total Accessories Live 1-Trimmer-DF 1.50" 1.50" 1.50" 316 715 447 1478 None 2-Trimmer-DF 1.50" 1.50" 1.50" 316 715 147 1478 None Tributary Dead Floor Live Snow Loads Location(Side) Width (0.90) (1.00) (1.15) Comments o-Self Weight(PLF) 0 to 3'3" N/A 13.2 1-Uniform(PSF) 0 to 3'3" 11' 15.0 40.0 25.0 ROOF/FLOOR 2-Uniform(PSF) 0 to 3'3" 2' 8.0 - - WALL /�� Weyerhaeuser Notes (t�SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. `1� Weyerhaeuser expressly disclaims any other warranties related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application,input design loads,dimensions and support information have been provided by Forte Software Operator 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred Ell Portland,OR 97219Mb 15226SW Greenfield Drive, Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 5 of 12 www.miller-se.com By Ck'd l Date Page ENGINEERS • ASCE 7-10 Seismic Design S,= 95.30% Risk Targeted Maximum Considered Earthquake(Figure 22-1,22-3,22-5,and 22-6)(pages 158 through 165) S1= 42.00% Risk Targeted Maximum Considered Earthquake(Figure 22-2,22-4,22-5,and 22-6)(pages 158 through 165) Fa= 1.12 Table 11.4-1,page 55 Fv= 1.58 Table 11.4-1,page 55 Sus=F,S,= 1.07 eqn.11.4-1 page 55 Su,=F„S1= 0.66 eqn.11.4-2 page 55 Sos=(2)Sus/(3)= 0.71 eqn.11.4-3 page 55 SD,=(2)Snw1/(3)= 0.44 eqn.11.4-4 page 55 Site Class D Table 20.3-1,page 152 Risk Category II Table 1.5-1,page 2 Seismic Force Resisting System A.Bearing Wall System 15.Light framed(wood)walls sheathed with wood structural panels rated for shear resistance Seismic Design Category(short per.) D Table 11.6-1,page 56 Seismic Design Category(1 sec) D Table 11.6-2,page 56 Seismic Design Category D (Controls) R= 6.50 Table 12.2-1,pages 60-62 = 3.00 Table 12.2-1,pages 60-62 Cd= 4.00 Table 12.2-1,pages 60-62 IE= 1.00 Importance factor,Table 1.5-2,page 4 CT= 0.02 Table 12.8-2,page 72 x= 0.75 Table 12.8-2,page 72 h„= 20 R,defined in section 12.8.2.1,page 72 T= 0.189 Eqn.12.8-7,page 72 k= 1.00 Section 12.8.3,page 73 Cu= 1.4 Table 12.8-1,page 72 Ta„„.= 0.265 section 12.8.2,page 72 C,= 0.109 Eqn.12.8-2,pg 72 T�= 16 Fig.22-12 through 22-16,page 170-173 C,= 0.360 need not exceed-Eq.12.8-3&12.8-4,page 71-72 C,= 0.031 shall not be less than-Eq.12.8-5&12.8-6,page 72 C,= 0.109 (control) TRIB WEIGHT TO GARAGE SHEARWALL 2nd Floor Trib 330 2nd Floor wt 15 psf 2nd Floor wt 4950 lbs Roof area trib 320 sqft Roof wt 15 psf Roof wt 4800 lbs Wall area trib 144 sqft Wall wt 8 psf Wall wt 1152 lbs Total wt to sh 10902 lbs Cs= 0.109 V= 1192 lbs Ultimate V= 840 lbs Allowable D°Cs jr ca aot 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred A Portland,OR 97219 15226SW Greenfield Drive, Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 6 of 12 www.miller-se.com By Ck'd 14'1 Date Page ENGINEERS WIND LOADING ANALYSIS - Main Wind-Force Resisting System Per ASCE 7-10 Code for Enclosed or Partially Enclosed Buildings Using Method 2:Analytical Procedure(Section 27&28)for Low-Rise Buildings Job Name: Subject: Job Number: Originator: Checker: Input Data: 11•11111=MIENISMN Wind Speed,V= 120 mph (Wind Map, Figure 26.5-1A-C) Bldg.Classification= II (Table 1.5-1 Risk Category) Wind • Exposure Category B (Sect.26.7) B Ridge Height, hr= 26.00 ft.(hr>=he) Eave Height, he= 19 00 ft. (he<=hr) Building Width= 60:00 ft. (Normal to Building Ridge) 1111��=��==� v Building Length= &O.6115- ft. (Parallel to Building Ridge) L Roof Type= Gable (Gable or Monoslope) Plan Topo. Factor, Kzt= 1.00 (Sect.26.8&Figure 26.8-1) Direct. Factor, Kd= 0.85 (Table 26.6) Enclosed?(Y/N) Y (Sect.26.2&Table 26.11-1) Hurricane Region? N 4 8 hr h<=60' Resulting Parameters and Coefficients: 1111 IN he El Roof Angle, 0= 13.13 deg. L Mean Roof Ht., h= 22.50 ft.(h=(hr+he)/2,for angle>10 deg.) Elevation Check Criteria for a Low-Rise Building: 1. Is h<=60'? Yes,O.K. 2. Is h<=Lesser of L or B? Yes,O.K. External Pressure Coeffs., GCpf(Fig.28.4-1): (For values,see following wind load tabulations.) Positive&Negative Internal Pressure Coefficients, GCpi(Table 26.11-1): +GCpi Coef.= 0.18 (positive intemal pressure) -GCpi Coef.= -0.18 (negative internal pressure) If h< 15 then: Kh=2.01*(15/zg)^(2/a) (Table 28.3-1) If h>= 15 then: Kh=2.01*(z/zg)^(2/a) (Table 28.3-1) (Note:z not<30'for Exp.B) a= 7.00 (Table 26.9-1) zg= 1200 (Table 26.9-1) Kh= 0.70 (Kh=Kz evaluated at z=h) Velocity Pressure:qz=0.00256*Kz*Kzt*Kd*VA2 (Sect.28.3.2, Eq. 28.3-1) qh= 21.95 psf qh=0.00256*Kh*Kzt*Kd*V^2 (qz evaluated at z=h) Design Net External Wind Pressures(Sect. 28.4.1): p=qh*[(GCpf)-(+/-GCpi)] (psf, Eq.28.4-1) Wall and Roof End Zone Widths'a' and'2*a'(Fig.28.4-1): a= 6.00ft. 2*a= 12.00 ft. 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 4111111 Suite One Hundred Portland,OR 97219 15226SW Greenfield Drive, Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 www.miller-se.com By Ck'd -. Date Page 7 of 12 ENGINEERS MWFRS Wind Load for Load Case A MWFRS Wind Load for Load Case B Surface GCpf p=Net Pressures(psf) Surface *GCpf p= Net Pressures(psf) (w/+GCpi) (w/-GCpi) (w/+GCpi) (w/-GCpi) Zone 1 0.47 6.38 14.28 Zone 1 -0.45 -13.83 -5.93 Zone 2 -0.69 -19.10 -11.20 Zone 2 -0.69 -19.10 -11.20 Zone 3 -0.43 -13.38 -5.48 Zone 3 -0.37 -12.07 -4.17 Zone 4 -0.37 -11.98 -4.08 Zone 4 -0.45 -13.83 -5.93 Zone 5 - --- --- Zone 5 0 40 4.83 12.73 Zone 6 --- --- --- Zone 6 -0.29 -10.32 -2.41 Zone1 E 0.71 11.70 19.60 Zone 1E -0.48 -14.49 -6.59 Zone 2E -1.07 -27.44 -19.54Zone 2E -1.07 -27.44 -19.54 Zone 3E -0.62 -17.49 -9.59 Zone 3E -0.53 -15.59 -7.68 Zone 4E -0.54 -15.89 -7.99 Zone 4E -0.48 -14.49 -6.59 Zone 5E --- --- --- Zone 5E 0.61 9.44 17.34 Zone 6E --- --- --- Zone 6E -0.43 -13.39 -5.49 *Note: Use roof angle 0=0 degrees for Longitudinal Direction. For Case A when GCpf is neg. in Zones 2/2E: For Case B when GCpf is neg.in Zones 2/2E: Zones 2/2E dist.= 30.00 ft. Zones 2/2E dist. = 30.00 ft. Remainder of roof Zones 2/2E extending to ridge line shall use roof Zones 3/3E pressure coefficients. MWFRS Wind Load for Load Case A,Torsional Case MWFRS Wind Load for Case B,Torsional Case Surface GCpf p=Net Pressure(psf) Surface GCpf p=Net Pressure(psf), (w/+GCpi) (w/-GCpi) (w/+GCpi) (w/-GCpi) Zone 1T --- 1.59 3.57 Zone 1T --- -3.46 -1.48 Zone 2T --- -4.77 -2.80 Zone 2T: __ --- -4.77 -2.80 Zone 3T -3.35 -1.37 Zone 3T --- -3.02 -1.04 Zone 4T 3 00 -1.02 Zone 4T --- -3.46 -1.48 Zone 5T --- --- --- Zone 5T --- 1.21 3.18 Zone 6T --- --- --- Zone 6T --- -2.58 -0.60 Notes: 1. For Load Case A(Transverse), Load Case B(Longitudinal),and Torsional Cases: Zone 1 is windward wall for interior zone. Zone 1 E is windward wall for end zone. Zone 2 is windward roof for interior zone. Zone 2E is windward roof for end zone. Zone 3 is leeward roof for interior zone. Zone 3E is leeward roof for end zone. Zone 4 is leeward wall for interior zone. Zone 4E is leeward wall for end zone. Zones 5 and 6 are sidewalls. Zone 5E&6E is sidewalls for end zone. Zone 1T is windward wall for torsional case Zone 2T is windward roof for torsional case. Zone 3T is leeward roof for torsional case Zone 4T is leeward wall for torsional case. Zones 5T and 6T are sidewalls for torsional case. 2.(+)and(-)signs signify wind pressures acting toward&away from respective surfaces. 3. Building must be designed for all wind directions using the 8 load cases shown below. The load cases are applied to each building corner in turn as the reference corner. 4.Wind loads for torsional cases are 25%of respective transverse or longitudinal zone load values. Torsional loading shall apply to all 8 basic load cases applied at each reference corner. Exception:One-story buildings with"h"<=30',buildings<=2 stories framed with light frame construction,and buildings<=2 stories designed with flexible diaphragms need not be designed for torsional load cases. 5. Per Code Section 28.4.4,the minimum wind load for MWFRS shall not be less than 16 psf. as 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred Portland,OR 97219 15226SW Greenfield Drive, Tigard, Oregon IS Location Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM 9/27/17 www.miller-se.com By Ck'd Ike, Date Page 8 of 12 ENGINEERS Low-Rise Buildings h<=60' O ., 0 CX Co .a> 411111 s Al `- S •"Y � �� Q�y^�r 4 i CK- Ccnu % 4). et16044 /ftrdYOM Cutrrc r - ;440001 0 MIN 0 '''. t � o Load Case A 1 a D lo U .` a ,c t ti 1 ixoww,s ntaMf `Cs` cora ower 14 1r> 0 T5 0 a v xb +o T' 0 Q c� �y d 0t4 LoCase w Basic Load Cases � :L � Zyy i^_`. � a ( I1 IN Case A Torsion .,,� Case B Torsion 'MM 943CTA'N Di...vA TO.V OM" ANKS Transverse Direction Longitudinal Direction Torsional Load Cases 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 11,4Suite One Hundred Portland,OR 97219 I 15226SW Greenfield Drive, Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM 9/27/17 9 of 12 www.miller-se.com By Ck'd 1 ->7 Date Page ENGINEERS WIND AREA CALCULATIONS ■. -'.;�iliiiiilrfiii�iiniiitiiii�ii 7niiii talliin iiiilii g ia' r �� �•nmm�minlnnnlnmm�llnnllsnnl�Innonul�mlmunnn:,_....,_.. °�-�� •Imnl�mm�nl�munmm�lumm�ull�nul�nulnlnnnlimmn "11�1111�IIIIiluNn111an111�1n['/IIIII�I►11lIiI111IIIIIIIICii1111II , . .,1II�IIII�IIIII�immiIIII�II�I�IIIil..■.....t 11111 ZONE Il .1misIIIIIiIIIIIS111111I1111 m ZONE 2,3 II11�111' II 11.iipl1�I-IIII�IIIIII`�I�Ilr�—Il�I�/(IIlr(Il�nulun�Ill1Il112E.31E i■ 114 .1111 11M11 I1d11iIII _ 1 FNpLAm ^ t1■Jl f�� rrrhIZO 1IJ1,,,1 D ■ l1(■k®IlL.E4E ZONE iI'' llilI11I11■ III�t Ii11 ,1nI2E,3E ' (�� ) .- —. - — —inI eEccbb-LAluKLoI I im ■IIII1Il1IlPhI8IPE!, � J I1 ,I„ ,I, II II h 11,1IIn NI1 , ZONE i.r-1 FNPLATE MGM 2E,3E Fll 4/cf di of 1 ZONE 1,4 ZONE tE,4E l ■ 11 _ J FNILOORIEYJLR 7 at 4 INTERIOR SHEAR WIND TO WIND TO • J' WALL LINE INTERIOR EXTERIOR WALL WALL LEFT $ E. LVATi0N ZONE 1+4: (49FT2 + 57 FT2) * (18.72PSF) = 1984 LBS ZONE 1 E+4E: (43 FTA2 + 37 FT2) * (28.12 PSF) = 2250 LBS ZONE 2+3: (32 FT2 + 40 FT2) * (16 PSF) = 1152 LBS ZONE 2E+3E: (32 FT2 + 20 FT2 + 14FT2) * (16 PSF) = 1056 LBS TOTAL WIND FORCE: 6442 LBS * (0.6ASD) = 3866 LBS *Wind controls the lateral design 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred St Portland,OR 97219Mk 15226SW Greenfield Drive, Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 10 of 12 www.miller-se.com By Ck'd 14.6-1, Date Page ENGINEERS SHEAR WALL CALCULATIONS Vr7 t, t II ! _I I 11 1, - i � il 2.31/4—• <' " �' . ,E13 ItAWu I � r 1 „nom^' i I � I r I it .• ) O I! V.. j I ii 74t7O 76ri10 /6xz0 j 1 4 l !; .1er,Ercis7i Nn= �. t F✓fmin7 It ii 1 I . I I1-16^-• i ( i .M m 4t.i i� l _ E,,c,l � HQ\OFR$ FrAmin \7 ' T L _.._.._. - _.__.______ -_-_.___."____.____ \ I I n I . 1 I ELEVATION OF WALL FRAMING WITH NEW OPENINGS i OT g i LJE115 Rx51DE1ts $OAJ_E Ya= I-° )5`I2'Zn 3k) Gc-E.14 'tE-kcc Dr 1,�jca•c ✓OA , Qi .T.i V MAX = 3866 LBS / (12.33' OF WALL PIERS BETWEEN WINDOWS) = 313 PLF CALCULATE STRAP TENSION AROUND OPENINGS ON NEXT PAGE USE 1/2" SHEATHING W/ 8D NAILS AT 6" OC EDGE AND 12" OC FIELD (CAPACITY = 364 PLF) s44 go`/c 71^-4,..444.4.4 ¢-z,it wr..e 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred Portland,OR 97219 l 15226SW Greenfield Drive,Tigard, Oregon Location 9 9 Client Exteriors, Inc. MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 BAM9/27/17 11 of 12 www.miller-se.com By Ck'd -1 Date Page ENGINEERS Punched Shearwall Analysis: Level:Roof Level Line:111 Segment Segment 1 This analysis uses the force transfer method of designing a punched shearwall. The free body diagrams shown,are for a generic condition. The input values H1&L1 should reflect the shortest sections adjacent to the window openings. Sequent Length. L V= 3866 lb Total shear force in segment L. _ L. L, L= 24.5 ft Total length of wall L,= 2.00 ft Smallest wall pier length L2= 3.00 ft Length of opening I . L3= 10.16 ft Remaining full height wall length I H= 9.50 ft Overall height of wall H�= 2.50 ft Critical section depth H2= 2.50 ft Height of opening \—Lontinuous strap above and below openings Single Upening Sequent Length, L k L L. Fh= 552 lb=3866/24.5`(2+0.5`3) Horizontal force at critical section'. _ I i P� �I Fv= 591 lb=552*(2.5+0.5*2.5)/(2+0.5*3) Vertical force at critical section. Sheathing Requirements: I _ X— Shearwall 15/32"APA Rated Sheathing Use 8d Nailing Single Sided Sheathing \\\ Use 40%SheanallIncrease Multiple Upenings `Lontinuouss strap above Side panels: and below openings Shear= 318 plf=3866/(2+10.16) Shear in wall piers. L. SL, Wall Type= A 'A'=8d At 6"o.c.edges,12"o.c.field 1.1 Vc= 364 plf 318 <364 OK Top and bottom panels: _,,� Shear= 236 plf=591/2.5 Shear in panel above opening. n Wall Type= A 'A'=8d At 6"o.c.edges,12"o.c.field F Vc= 364 plf 236 <364 OK 'Use Type A shear wall(8d At 6"o.c.edges,12"o.c.field)for all of Segment 1 on wall line R1 at the Roof Level shearwalls. Strap Requirement: P= 355 lb=591*(0.5*3)/2.5 Critical strap force. Tension= 355 lb per strap Tc= 845 lb 355 <845 OK Use Simpson CS22 strap(s)x 24.5'long above and below opening. Strap to extend full length of shear wall segment with shear wall edge nailing requirements. Strap to be placed over sheathing and nailed to blocking. Sole Plate Base Anchorage: Shear= 158 plf=3866/24.5 Shear at top and bottom plates. Wall Type= A can be used for sole nailing and anchor bolt spacing Vc= 364 plf 158 <364 OK 9570 SW Barbur Blvd Project Name Wells Residence Front Shear Wall Analysis Project# 171116 Suite One Hundred Portland,OR 97219 Location 15226SW Greenfield Drive, Tigard, Oregon MILLER Client Exteriors. Inc. Phone 503.246.1250 CONSULTING Fax 503.246.1395BAM 9/27/17 12 of 12 www.miller-se.com By Ck'd } Date Page ENGINEERS