Loading...
Specifications sr 0. 1J J3 MAIN / S/_ 7 c-c `/ 1 / 7'7 10-13-15 Roseburg `�7 " / 6 11:02am A Forest Products Connpam 1 of 1 CS Beam 4.21.0.1 1ctnBeamEngine 4.13.8.1 Materials Database 1534 Member Data Description: Member Type:Joist Application: Floor Top Lateral Bracing:Continuous Bottom Lateral Bracing:Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, U240 total Dead Load: 12 PSF Deck Connection:Glued&Nailed Filename: Beam1 19 7 0 m 19 7 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) N/A 1.750" 821# — 2 19' 7.000" Wall DFL Plate(625psi) N/A 1.750" 821# — Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 631#(395p1f) 189#(118plf) 2 631#(395p1f) 189#(118plf) Design spans 19' 8.750" Product: DBL 11 7/8" RFPI-20 19.2" O.C. PASSES DESIGN CHECKS Minimum 1.75"bearing required at bearing#1 Minimum 1.75"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4048.'# 7280.'# 55% 9.79' Total Load D+L Shear 821.# 2840.# 28% 0' Total Load D+L TL Deflection 0.4605" 0.9865" U514 9.79' Total Load D+L LL Deflection 0.3542" 0.4932" L/668 9.79' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% SIMPSON Mpoductnamesamtademaksoftheir espectiveownes KAMI L HENDERSON EWP MANAGER copy ght(c>2o7s by s meson st ang re company lnc.nLL RICI ns lzeseRveo. PACIFIC LUMBER&TRUSS "Passing is defined as when the rtrember,floor joist,beam or giNer,shown on this dravirg meets appliraWe design cdteda for Loatls,Loading COMdior¢,antl Spans listed on this�.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer s spedfications. 503-858-9663 • 0 Roseburg J4 BASEMENT 10-13 15 11:01am A Forest Pmducts Company 1 of 1 CS Beam 4.21.0.1 lanBeamEngine 4.13.8.1 Materials Database 1534 Member Data Description: Member Type:Joist Application: Floor Top Lateral Bracing:Continuous Bottom Lateral Bracing:Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: U480 live, L/240 total Dead Load: 12 PSF Deck Connection:Glued&Nailed Filename: Beam1 10 6 0 10 0 0 2060 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 302# — 2 10' 6.000" Wall DFL Plate(625psi) 3.500" 3.500" 870# — 3 20' 6.000" Wall DFL Plate(625psi) 3.500" 1.750" 287# — Maximum Load Case Reactions Used for applying peed bads(or rine loads)to carrying meters Live Dead 1 239#(179plf) 63#(47plf) 2 669145020lf) 201#(151p1f) 3 229#(172p1f) 58#(43plf) Design spans 10' 3.375" 9' 9.375" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 654.'# 2820.'# 23% 4.33' Odd Spans D+L Negative Moment 874.'# 2820.'# 30% 10.5' Total Load D+L Shear 441.# 1220.# 36% 10.49' Total Load D+L End Reaction 302.# 1151.# 26% 0' Odd Spans D+L Int.Reaction 870.# 1775.# 49% 10.5' Total Load D+L TL Deflection 0.0643" 0.5141" U999+ 4.85' Odd Spans D+L LL Deflection 0.0540" 0.2570" U999+ 4.85' Odd Spans L Control: Max Int React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% SIMPSON AtpmductRum"are trademarhsofthew nespectiveowners KAMI L HENDERSON EWP MANAGER Stiongl`Ie' copydgtt(c)2015bysimpsonstmgreconoaml�uLRlclnsr�serty®. PACIFIC LUMBER&TRUSS "Passing rs defined as when the member,fioorjoist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading condhons,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed M a qualRed designer or design professional as required for approval This design assumes product installation according to the manufacturer s specifications. 503-858-9663