Loading...
Plans (69) '"Global Protect Values: SILENT i Project Name;Artistic Auto Bod KNIGHT 1 y 1, standby Hours•.) 5 1 Pro}ect1 al I Alarm Mins;: 5 f TO i =P'roiiarez By, Phillips Electronics ( = -Oer ting Fapttyrr 1 2 5104 Calculations Date,.10/9/2017 I 'oltageDrop Vltaining" Version 0521 10 'fhreshdd°%;� 10 Panel ID: 5104 Model 5104 Fire Communicator Max NAC Current: 0.75 Amps, Location: Volts,' 12 VDC Max Panel Curren`t 1.3=Amps Ckt;# Circuit Name Current Draw Wire AWG Ohms Per .Length(ft} Actual Volts c o q Standby .Alarm &Type 1000°Ft One-Wad; Ohms OL kDrop 5104°= 5104 Fire Comm. 0.075 0.135 5230 5230 LCD Remote 0.000 0.000 IDC-1 ..; Init- iating Device Ckt 1 - 0.000 . 0.000 IDC-2 . InitY iatinnc Device Ckt 2 _ 0.000 0.000 IDG,,=3 Initiating Device Ckt 3 _ 0.000 0.000 IDG-4 Initiating Device Ckt 4 _ 0.000 0.000 IDC-5 Initiating Device Ckt 5 _ 0.000 0.000 IDC-6 Initiating Device Ckt 6 0.000 0.000 NAC-1 Notification' AppI Ckt 1 0.000 0.000 #12 Solid 0.00 1.59 20 40 0.00% Total Standby Current(Amps] 0.075 0.135 Total Alarm Current-(Amps} Standby Timein Hours 24, 0.083 Alarm Time In Minutes/60 (5 Mins}, Total Standby AH'Required 100.2..80040000001::3;0000....001008_300035000,, .801) 0.011 Total Alarm'AH Required Total Combined AH°Required 1.81 Command Shortcuts Multiply By The berating Factor 1.20 Page Battery AmpHours Required >2.17°' Configure Circuits Print Pa e CITY OPTIGARD REVIEWED FOR CO COMPLIANCE Approved: I t, 1 OTC: ( J Permit#: , 72Ot7 oO ( �, t Address: `�'� ''5'4 -2C (- Suite •• . , ,L.2.a.__. L.7 By: i wv Date: OFFICE COPY N . . TIGARD UlPER ALARM MAP ,r,..,.A.,0i ,0 T w Iiii).•.* E Nr '' s 4111 U/ / 1st Floor , MAP LEGEND sbect • Man Door(7) = 0 Garage Door(10) = p --- I 0,-,--1 0 On/Off Keypad(3) _....- _r = C v;', LL Interior Camera(?) ...., , 4 """ Exterior Camera(?) 1 inedi(A6C01. ---oi: _ .... , • iminnu , )0:‘l'T Vi-Ter FliAt(1V. *'s.. 41 • &AAA's (NIo,H, , . 1111111111im Body , , sl'of-) - , . , r , ....., r i ) Ail 1:1111.111 illi i iiwitti, e •4 OF .... - C ....._ krle.., E • F,r,.. )4,..,/,,, c, ,,t•i&,, F.,_,A,,\ gia 40/4- E . 5..,, ER 4 rE aliMel.106.1.... ..,‘ N TIGARD UPPER ALARM MAP ,�,,:,zix4, -1:E 2nd Floor s s______- _.,.,= ;__ .. _ ____ MAP LEGEND • Man Door(4) —..--1...,- 0 On/Off Keypad(1) I Interior Camera(?) �'"-i r `� ��1p I /F _.� i 1 Exterior Camera(?) /7 pii ___ _ ,) NNNe_. In 1 , ---‘. I DGCIS )IQ per G 11111) • \sr- 11IIIH tIN 4i 1..—.1 i-- Pica— ,'.1( 1 ( '',;,~ OF < . • M JIIM y� cz � 1 C\ ? FIRE ALARM ACCESSORY ItSILENT 10413 Fire Control KNIGHT Communicator © OCT 16 2017 by Honeywell TA ,, If P'iNSDAtie teeliability and value inn in v i o • igital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines—eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard—the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800-328-0103. Model 5104B the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a 60 seconds, it will automatically six-zone fire control communicator switch to the other to report the providing digital fire reporting over failure. I •' ordinary telephone lines, The communicator will signal eliminating the need for costly activation, restoration and trouble leased lines. It's UL 864 and NFPA conditions on any of six inputs. If ito *MS, 72 approved for monitoring local an application requires a different evacuation controls. input configuration, the individual �� p g dua As a stand-alone unit, it can be input styles may be changed by Modal 5104B used to monitor: using a Model 7181 Fire Zone • Sprinkler systems for waterfiow, Converter Module. The 7181 also supervisory, and gate valve allows use of two-wire type smoke Dual phone line interface Automatic tamper conditions. detectors, instead of the normal self tests every 24 hours with report four-wire contact type, for sent to central station. • Automatic fire detection systems automatic fire detection • Reports in SIA and most major for structures that are not applications. communications formats. required to have a fire alarm system but want property Features • 60 hours of standby power. protection (e.g. to call the fire • UL 864 Listed as an NFPA 72 • Operates on loop start phone lines department after hours). Central Station or Remote Station ahead of the building PBX system. Monitors dry contact alarms, protected premise unit. • A single, programmable output is • • FM approved. provided for alarm or dialer failed trouble and supervisory outputs, conditions(cannot be used for •then transmits a separate code Can be used as a stand-alone or as evacuation purposes). for each. a add-on DACT. The Model 51048 is fully • Six fully supervised inputs:one Class A(Style D)input, and five supervised. Its microprocessor Class B (Style A)inputs. constantly runs programs to • Downloadable for remote monitor AC, standby battery, zone programming. inputs and telephone line • Fuseless overload protection with connections. If a fault condition is automatic reset circuitry and fault detected, it sounds a local trouble indicators—eliminates the cause of audible and reports the condition to most field calls. FIRE/ARM ACCESSORY 5104B Fire Control Communicator Specifications Mechanical: Electrical Dimensions: 12.25"W x 14.5"H x 3.0"D Add-on Applications-UL Listed (31.1cm W x 36.8 cm H x 7.6cm D) Input: 120 VAC 60 Hz 40 watts Weight: 15 lbs.(6.75 kg) Current: Color: Red Standby 50 mA Alarm 135 mA Optional Accessories: Stand Alone Applications 5230 Remote Annunciator/Programmer Input: 120 VAC 60 Hz 40 watts 5561 Download Package Standby: 12 volt 7 amp hour rechargeable battery 7181 Fire Zone Converter Module 5230 Remote Annunciator(three maximum per system) 7860 Telephone Connecting Cord for RJ31X Jack(2 required) Load: 60 mA standby 6712 12 volt,7AH rechargeable battery 120 mA alarm Communication Formats: SIA,SK 3/1,Sescoa 3/1,Contact ID, Indicator Lights(LEDs): SK 4/2,Radionics BFSK Power On(Green) Approvals: Trouble Silenced(Yellow) UL Listed-UL864/NFPA 72 Central and Remote Supervising Until Trouble is Cleared/Flashing=Supervisory Station Fire Alarm System Service. Dialer Failure(Yellow) FM Approved Telephone Line Fault(2 Red) CSFM Approved Inside Cabinet at L1 and L2 Inputs MEA Telephone Requirements: FCC Registration#:AC698R-17462-AL-E RINGER EQUIVALENCE 0.08 Type of Jack:RJ31X(2 required) Model 5230 Remote The Model 5560 SKSS Alphanumeric Annunciator Downloading Package The 5104B can be programmed Allows for remote programming through the use of the optional and status checking of the 5104. Model 5230 Remote Alphanumeric Includes a 3 1/2-inch disk and Annunciator. Programming options Silent Knight proprietary modem. include: telephone numbers, Allows the installing company to KF reporting format, account number, view the default programming, loop response times (electronic modify it, and if necessary, ® son i retard), test time, output activation, troubleshoot the system. Designed � user and installer codes. System to be used on an IBM or programming is stored in a non- compatible PC. The downloading volatile EEPROM chip which is software also contains programs for reprogrammable hundreds of times. other Silent Knight downloadable Model 5230 The 5104B accommodates up to products. 5 1/4-inch disks available three remote annunciators via a upon request. four-wire connection.A quick- connect plug allows temporary connection of the annunciator for programming. FIRE ALARM ACCESSOR 5104B Fire Control Communicator 120VAC 60 Hz U L-LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 5104B 6 Channel Silent Knight Model 5230 Communicator (optional) Remote Annunciator Alarm Contact (3 max per system) (N.O.Typical) 0,"Trouble Contact, Tel. Line#1 To RJ31X (N.C. Typical) 00' Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Add-On DACT Application SILENT KNIGHT MODEL 51048 120VAC 60 Hz I 6 Channel Silent Knight Class A Input Communicator Model 5230 (supervised) 0-0-0--0--0— (optional) Max 5 waterflow devices as per NFPA 72 Remote Annunciator (3 max per system) • Class B Inputs Wheelock (supervised) MB-G10-12-R Gate valve tamper or PIV Tel.Line#1 • supervisor-must connect To RJ34X normally open Model 6712 12VDC 7 AN Tel.Line#2 MODEL 5104B BLOCK DIAGRAM Stand-alone Waterfiow Application Fw . r Communicators: ercantile Models • Universal full event sole path cellular commercial UL and NFPA 72 Fire Code-Compliant,the StarLink Series fire alarm reporting from any panel brand,virtually Wireless Commercial Fire Alarm Communicators provide universal support for any brand 12V to 24V fire alarm control anyvvhere panel,reporting in Contact ID and 4/2. With broadest coverage •For use as primary or backup communications on all footprint available in Verizon Network Certified TM CDMA or GSM 12V-24V control panels and FACPs that communicate 3/4G models on the AT&T network,as well as mercantile models, all provide the most economical solution and for easy,versatile using Contact ID and 4/2(such as on legacy panels) installation. • Reports to any Central Station nationwide,with your Safeguard Accounts&Reliability.For applications currently Choice of cellular networks:Verizon Network Certified relying upon quickly-disappearing traditional phone lines, CDMA or GSM 3/4G on AT&T StarLink wireless communicators can be used for primaryor backup communications,and will not only safeguard the fire • Easy,flexible installation, activation &online account alarm reporting transmissions for the future,but provide the management end user monthly savings for each costly FACP-dedicated landline they replace. And,for upgrading older wireless firealarm • Cost-saving cellular models and plans for any code communicators on 2G and other phased-out cellular networks, requirement.Substantial savings over monthly dedicated standard StarLink Fire Models,SLE-CDMA-FIRE and SLE-GSM landline charges.And,$70 saving incentive with any 2G FIRE,offer a$70 tradeup incentive to help defray the cost of the Communicator upgrade(unlimited). hardware replacement to the advanced state-of-the-art StarLink model of choice. Flexible Performance&Reporting Options.StarLink Fire provides full data reporting,as a primary or backup;to any central station of your choice,without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes and requirements,mirth supervisory check-ins from 2i00 ,� seconds,to 5 minut�.to an hour, ;The units are very easy ly activated,plans and options are selected,and 24/7 account management is provided all through wwwnapcocomnet.com, And,Starlink Fire Communicators are easily connected to any panel or Fire Afarm,Control Panel(FACP)standardly i.. operating"between 12N/and 24V. Flexible in any K, application,Start-ink Fire also comes in standard,or x fir' "le-Models in metal housings,with code- compllant su t i ,wrtt rr or without using ,cooduit and choke of power o�* ,� powered Ahe panel, 0E404 4100)00 e * Tp�r'3uI ...«-_. ..F- ..,wino.... .-......r9.....:-. , �<. � .» �c�rstl7irarrt stari�rd or xrrercatt#rle ine�(ir#�s(right and k respectiva(yr twt Universal sole Path Fu � rsMapco tarin e • Choice of plans with varying supervisory check-ins from •• 8on rs f=uH High-�`Mapco Panel remote 200 seconds,to S-minutes to 1 hour,Verizon or AT&T uploading/downloading • Patented Signal Boost'r signal amplification circuit COMPLIANCES;NFPA72 Editions:2013,2010,2007; $.;',, and high-gain performance antenna for longer range UL 864,9th Ed.,UL161 O,UL985,UL1023, Nce`'' / and reliability nationwide NYFD(as back-up);CSFM r ` , • Money-saving 2G Tradeup incentive cream 1 "EE1 ..p ' -++✓ NETWORK °4.W • ; Vefl QR CERTIFIED,tymmt itrIAL(IRAQI Otr il: r< • '1/47,4 e • • ;: - < > $E �Cbli�lA F & scrim IIIb gral„S • . • Durable A .plastic ing irldf th1 keyhole slats for SLE-CSF( standard"ABS (Red)Fire Sole Path Alarm m (for sir rr ircia!appli ion- l wit#i ale gang Gorr�i mun tor,CDMA,Vernon-N r#Gets boxers,} SU as e,but GSM`314 3 an AT&TlNetwork • C3tmensitnls �-��x<?"7'`/8"�x 1 7f8"t#�t�# ., • Weight 13 5 0i SLEC A -A Com atizon l Fire Mer the model la red metal housing,COMA for backup euse ery/charger)..O,Optional ,Activatia iCatCW 1`-Gree CRF2°plug-iin.trarrsfzi nen may be used,where codes permit • Patented Signal Boost'"•signal a i cation circuit and high- SLE3/4+ -CF PS as.above,but GSM 3/4G on AT&T Network gain pe I'' ;gaac antenn BLECDM#-CF$Commercial Fire Mercantile model in red metal • Operating torment: to 49° to 93% housing on CDMA,Verizon-Network Certified Powered directly humidiiy(non c 1e ) from control panel • 12V-2!tV S 'n contact SLE3/4G-CFB as above,but GSM 3/4G on AT&T Network Support all bran%�S t�m�rtutlit:�rtyrig in,Cort ID ar►c#4/2 • Powered by Panes,t,ow urrent draw,71mA standby.200mA ACCESSORIES: ransrnit SLE-DLEXT Optional,as above,for downloading,extends distance NIERC"�1.1 ? to Napco panel up to 100' • Locking:Metal En IrewKh Hinged door& 2 key-siots for wall TRF20 Optional Plug in AC Transformer, 16.5V/20VA(use is subject mounting(LEDindicators inside). to local code compliance) • Oirr ions -9-SfS1x 11.3/4"x 3-3/8"D(HxWxD) SLE-DLCBL Optional High-Speed Napco Panel Up/download cable • Weight 8 lbs(ix.,power supply models) • Electrical Ratings for 120VAC,60Hz For Models with Power Supply: Input Voltage: 120VAC Nominal • input Current:400mA maximum • Maximum Charging Current 200mA • Electrical Ratings for+12V • For Models without Power Supply: • Input Voltage: 11-15V DC(power-limited output from listed control panel) • Input Current:71 mA with peak RF transmission current of 200mA. • Electrical Ratings for the IN 1 Burg/Fire Input: • • Input Voltage:9-15VDC L • Maximum Input Current:Up to 2mA from FACP NAC circuit • Electrical Ratings for IN 2 and IN 3: • Maximum Loop Voltage:15VDC • Maximum Loop Current: 1.2mA • Electrical Ratings for 3 PGM Outputs: Erdil N�RC0• Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not activevT + - • Maximum PGM Sink Current 50mA mount. 333 Bayview Ave.,Amityville,NY 11701 USA 1-800-645-9445 •Fax:1-631-789-9292 • Operating Environment 0 to 490C(32-120'F),up to 93% IIII www.napcosecurity.com humidity(non-condensing) • 12V-24V Universal FACP Support,auto-current sensing. \------ NErwoRK N U°4mi' CERTIFIED Support all brands communicating in Contact ID and 4/2. COMPLIANCES:NFPA 72 Editions:2013,2010,2007; UL 864,9th Ed.,UL1610,UL985,UL1023;NYFD(as back-up);CSFM *StarLink Fire are also rated to support Intrusion/Burglaryolarm reports where applicable.StarLink°'and Signal Boost are trademarks of NAPCO.Pats.Pending.-Speciricatkms subjecttadtarjga - ®NAPCO,NAPCo Security Technologies Inc(NASDAQNSSC) A676 2,016.1 - - r % *%/wean Vetfzon '`it, 1 V erc�iks ✓ ..�' i �t�'s'hs, . . * '' ' <rx�c�'w FIRE ALARM ACCESSORY 5104B Fire Control Communicator SILENT KNIGHT MODEL 5104B 120VAC 60 Hz Silent Knight 6 Channel Model 5230 Class A Input 0 Communicator , (optional) (supervised) Remote Annunciator (3 max per system) 0 Class B Inputs Wheelock (supervised) MB-G10-12-R Heat detectors,manual 10/' (optional) pull stations and Tel. Line#1 contact type Model 6712 To RJ31X smoke detectors _ 12VDC 7 AH M, Tel. Line#2 MODEL 5104B BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application (For Communication Only) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries.The secondary approved digital communicator to telephone line (number)at alternating supply shall be capable of supplying 24-hour intervals in accordance with power, under maximum normal load, transmit the fire alarm and supervisory and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. central station over the remaining The communicator shall be able to The digital communicator shall provide phone line.A signal shall also be transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format(Security Industry Association). six supervised detection circuits. One phone service.The shall be Class A(Style D)and five shall control/communicator shall be able to The alarm signals transmitted to the be Class B (Style A).The detection report the loss of either phone line central station shall indicate which of circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches,gate valve supervisory failed first. If both lines fail, a local zones are in trouble. Restoral from switches,thermal detectors andsignal shall sound. alarm or trouble shall be capable of contact-type smoke detectors communicating to Silent Knight, and intermixed as desired and permitted by The control/communicator shall have other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours.The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines,seize the phone line setting a program within the panel. i SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are PN 350349,Rev Cl by Honeywell subject to change without notice.For more information,contact Silent Knight ©2010 Honeywell International Inc. 12 Clintonville Road,Northford,CT 06472-1610.Phone:(800)328-0103, Fax:(203)484-7118. www.silentknight.com