Report (72) Pes)-0(7.-a414 Capitol o&o0 s-w �l Electric Co., Inc. RECEIVED October 9, 2017 OCT i 7 2017 CITY OTGA BUILDING DIVISION Plans Examiner City of Tigard Building Services 13125 SW Hall Blvd. Tigard, OR 97223 Re: Tenant Fire Alarm System Additions Farmer's TI 6600 SW Hampton Street Tigard, OR 97223 Please find attached building and electrical permit applications, three sets of plans, calculations, and product submittals for the fire alarm tenant improvements at the address shown above. Occupancy Group: B The fire alarm system design includes the following: 1. Install new ADA synchronized fire alarm notification devices in the tenant space including (33) horn/strobes & (22) strobes. 2. Install (1) new NAC power supply. 3. Install (1) duct smoke detector for supervisory shutdown of RTU 10. 4. We will pre-test the fire alarm devices prior to requesting a final fire alarm inspection. Please contact me if you have questions or comments. Respectfully, Shane Terce Project:Manager/Estimator Fire/Life Safety Division Capitol Electric Company, Inc. (503)262-0405 Direct shane@cepdx.com NICET Level II, Fire Alarm Systems #140599 11401 NE Marx • Portland, Oregon 97220-1041 • 503-255-9488 • Fax 503-257-7121 CCB# 48748 • www.capitolelectricco.corn NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. RECEIVED (503)255-9488 Office (503)255-1966 Fax OCT 17 2017 Job Name: Farmers TI 1 '� ARD Job Address: 6600 SW Hampton Street Tigard, OR 97223 BUILDING DIVISION Job Number: Conductor Wire Gauge 14 Prepared By: Shane Tercek Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) 3.07 `Date: 10/4/2017 Cable Length In Feet(source to end of line) 0 Total Circuit Current 0 Nominal System Voltage 20.4 Panel Description: Potter PSN-106 Minimum Device Voltage 16 Panel No.: 1.1 Output No.: 1 Point To Point Method EOLv 20.40 Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock Load Centering Method EOLv 20.40 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device „_ . .r. v. 1 s.are 20.40 2 -- 20.40 3 --_- 20.40 4 -- 20.40 5 ---� 20.40 6 -- 20.40 7 -- 20.40 8 ---_ 20.40 9 ---� 20.40 10 -- 20.40 11 -- 20.40 12 -- 20.40 13 -- 20.40 14 -- 20.40 15 -- 20.40 16 -- 20.40 17 -- 20.40 18 20.40 19 ---- 20.40 20 ---_ 20.40 Farmer's TI EOLv Calc NAC, 6 CKT(20.4V Nominal).xls OUTPUT 1 NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503)255-9488 Office (503)255-1966 Fax Job Name: Farmer's TI Job Address: 6600 SW Hampton Street Tigard, OR 97223 Job Number: Conductor Wire Gauge 14 Prepared By: Shane Tercek Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) 3.07 Date: 10/4/2017 Cable Length In Feet(source to end of line) 538 Total Circuit Current 1.641 Nominal System Voltage 20.4 Panel Description: Potter PSN-106 Minimum Device Voltage 16 Panel No.: 1.1 Output No.: 2 Point To Point Method EOLv 17.54 Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock Load Centering Method EOLv 17.69 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet) 1 S.OFFICE AREA HSW 75) H/S-Wall,White,Hi 75Cd 0.148 42 19.98 2 S.OFFICE AREA HSWC 15) H/S-Ceil, White, Hi 15 Cd 0.082 20 19.79 3 S.OFFICE AREA STWC (15 Stb-Ceil, White 15 Cd 0.061 28 19.55 4 S.OFFICE AREA STWC (30 Stb-Ceil, White 30 Cd 0.085 29 19.31 5 S.OFFICE AREA HSW 15 H/S-Wall, White, Hi 15 Cd 0.082 25 19.12 6 S.OFFICE AREA HSWC (15) H/S-Ceil, White, Hi 15 Cd 0.082 39 18.83 7 S.OFFICE AREA HSW(75) H/S-Wall, White, Hi 75 Cd 0.148 19 18.70 8 S.OFFICE AREA STWC (30) Stb-Ceil, White 30 Cd 0.085 26 18.55 9 S.OFFICE AREA STWC 15) Stb-Ceil, White 15 Cd 0.061 26 18.41 10 S.OFFICE AREA STWC (15) Stb-Ceil, White 15 Cd 0.061 37 18.23 11 S.OFFICE AREA HSWC (30 H/S-Ceil, White, Hi 30 Cd 0.102 29 18.10 12 S.OFFICE AREA HSWC (15 H/S-Ceil, White, Hi 15 Cd 0.082 42 17.93 13 S.OFFICE AREA HSWC (30) H/S-Ceil, White, Hi 30 Cd 0.102 28 17.84 14 S.OFFICE AREA HSWC (15) H/S-Ceil, White, Hi 15 Cd 0.082 32 17.74 15 S.OFFICE AREA HSWC 15) H/S-Ceil, White, Hi 15 Cd 0.082 43 17.64 16 S.OFFICE AREA HSWC (75) H/S-Ceil, White, Hi 75 Cd 0.148 41 17.57 Nam S.OFFICE AREA HSWC 75) H/S-Ceil, White, Hi 75 Cd 0.148 32 17.54 18 -- 17.54 19 ---- 17.54 20 --_-■ 17.54 Farmer's TI EOLv CaIc NAC, 6 CKT (20.4V Nominal).xls OUTPUT 2 NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503)255-9488 Office (503)255-1966 Fax Job Name: Farmer's TI Job Address: 6600 SW Hampton Street Tigard, OR 97223 Job Number: Conductor Wire Gauge I 14 I Prepared By: Shane Tercek Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) I 3.07 I Date: 10/4/2017 Cable Length In Feet(source to end of line) I 613 I Total Circuit Current I 1.868 I Nominal System Voltage I 20.4 I Panel Description: Potter PSN-106 Minimum Device Voltage I 16 I Panel No.: 1.1 Output No.: 3 Point To Point Method EOLv 16.53 Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock Load Centering Method EOLv 16.88 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device e 1 N&S CENTER OFFICE AREA HSW(75) H/S-Wall, White, Hi 75 Cd 0.148 87 19.40 2 N&S CENTER OFFICE AREA HSW 110) H/S-Wall, White, Hi 110 Cd 0.197 38 19.00 3 N&S CENTER OFFICE AREA HSWC (15) H/S-Ceil, White, Hi 15 Cd 0.082 26 18.76 4 N&S CENTER OFFICE AREA HSWC (15) H/S-Ceil, White, Hi 15 Cd 0.082 39 18.41 5 N&S CENTER OFFICE AREA HSW(110) H/S-Wall, White, Hi 110 Cd 0.197 50 18.00 6 N&S CENTER OFFICE AREA HSW(75) H/S-Wall, White, Hi 75 Cd 0.148 46 17.67 7 N&S CENTER OFFICE AREA STWC (30 Stb-Ceil, White 30 Cd 0.085 22 17.53 8 N&S CENTER OFFICE AREA STWC (30) Stb-Ceil, White 30 Cd 0.085 29 17.36 9 N&S CENTER OFFICE AREA STWC 15) Stb-Ceil, White 15 Cd 0.061 32 17.20 10 N&S CENTER OFFICE AREA HSW(75 H/S-Wall, White, Hi 75 Cd 0.148 23 17.09 11 N&S CENTER OFFICE AREA HSWC 95 H/S-Ceil, White, Hi 95 Cd 0.176 72 16.81 12 N&S CENTER OFFICE AREA HSW(75) H/S-Wall, White, Hi 75 Cd 0.148 50 16.67 13 N&S CENTER OFFICE AREA STWC 95) Stb-Ceil, White 95 Cd 0.163 50 16.57 14 N&S CENTER OFFICE AREA HSW(75) H/S-Wall, White, Hi 75 Cd 0.148 49 16.53 16 15 =--- 16.53 _ 17 16.53 16.53 18 -- 16.53 19 20 --.. -_ 16.53 16.53 Farmer's TI EOLv Calc NAC, 6 CKT(20.4V Nominal).xls OUTPUT 3 NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503)255-9488 Office (503) 255-1966 Fax Job Name: Farmer's TI Job Address: 6600 SW Hampton Street Tigard, OR 97223 Job Number: Conductor Wire Gauge I 14 I Prepared By: Shane Tercek Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) I 3.07 I Date: 10/4/2017 Cable Length In Feet(source to end of line) I 478 I Total Circuit Current I 1.136 I Nominal System Voltage I 20.4 I Panel Description: Potter PSN-106 Minimum Device Voltage I 16 I Panel No.: 1.1 Output No.: 4 Point To Point Method EOLv 17.99 Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock Load Centering Method EOLv 18.73 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet) (135 H/S-Wal 1 NE OFFICE AREA HSW I, White, Hi 135 Cd 0.242 232 18.78 2 NE OFFICE AREA STWC (15 Stb-Ceil, White 15 Cd 0.061 19 18.68 3 NE OFFICE AREA STW (30 Strobe-Wall, White 30 Cd 0.085 23 18.56 4 NE OFFICE AREA STWC 15) Stb-Ceil, White 15 Cd 0.061 26 18.44 5 NE OFFICE AREA HSW 185) H/S-Wall, White, Hi 185 Cd 0.282 21 18.35 6 NE OFFICE AREA STWC (15) Stb-Ceil, White 15 Cd 0.061 95 18.12 7 NE OFFICE AREA HSW 30) H/S-Wall, White, Hi 30 Cd 0.102 52 18.01 8 NE OFFICE AREA HSW(135) H/S-Wall, White, Hi 135 Cd 0.242 10 17.99 9 17.99 10 17.99 11 17.99 12 -_- 17.99 13 17.99 14 -_- 17.99 15 17.99 16 -_- 17.99 17 17.99 18 -_- 17.99 19 17.99 20 17.99 Farmer's TI EOLv Calc NAC, 6 CKT (20.4V Nominal).xls OUTPUT 4 NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503) 255-9488 Office (503)255-1966 Fax Job Name: Farmer's TI Job Address: 6600 SW Hampton Street Tigard, OR 97223 Job Number: Conductor Wire Gauge 14 Prepared By: Shane Tercek Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F) 3.07 Date: 10/4/2017 Cable Length In Feet(source to end of line) I 477 I Total Circuit Current I 1.011 I Nominal System Voltage I 20.4 Panel Description: Potter PSN-106 Minimum Device Voltage I 16 Panel No.: 1.1 Output No.: 5 Point To Point Method EOLv 18.21 Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock Load Centering Method EOLv 18.92 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device 1 W OFFICE AREA HSW(15 H/S-Wall,White, Hi 15 Cd 0.082 180 19.28 2 W OFFICE AREA HSWC (15) H/S-Ceil, White, Hi 15 Cd 0.082 37 19.07 3 W OFFICE AREA HSW (15) H/S-Wall, White, Hi 15 Cd 0.082 25 18.94 4 W OFFICE AREA STWC (30) Stb-Ceil, White 30 Cd 0.085 42 18.74 5 W OFFICE AREA HSW 15 H/S-Wall, White, Hi 15 Cd 0.082 29 18.62 6 W OFFICE AREA STWC 15 Stb-Ceil, White 15 Cd 0.061 16 18.56 7 W OFFICE AREA STWC (15) Stb-Ceil, White 15 Cd 0.061 22 18.49 8 W OFFICE AREA HSW 15 H/S-Wall, White, Hi 15 Cd 0.082 17 18.44 9 W OFFICE AREA MEZZANINE HSW(110) H/S-Wall, White, Hi 110 Cd 0.197 79 18.25 10 W OFFICE AREA HSW(110 H/S-Wall, White, Hi 110 Cd 0.197 30 18.21 11 18.21 12 13 , =-� 18.21 18.21 14 -- 18.21 15 -- 18.21 16 _ 17 ■ =-�- 18.21 18.21 18 -= 18.21 19 ---_ 18.21 20 ---- 18.21 Farmer's TI EOLv Calc NAC, 6 CKT(20.4V Nominal).xls OUTPUT 5 NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503)255-9488 Office (503)255-1966 Fax Job Name: Farmer's TI Job Address: 6600 SW Hampton Street Tigard, OR 97223 Job Number: Conductor Wire Gauge 14 Prepared By: Shane Tercek Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) 3.07 bate: 10/4/2017 Cable Length In Feet(source to end of line) 260 Total Circuit Current I 0.741 Nominal System Voltage 20.4 Panel Description: Potter PSN-106 Minimum Device Voltage I 16 I Panel No.: 1.1 Output No.: 6 Point To Point Method EOLv 19.54 Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock Load Centering Method EOLv 19.81 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device Feet) 1 NW OFFICE AREA HSW(110) H/S-Wall, White, Hi 110 Cd 0.197 110 19.90 2 NW OFFICE AREA STWC (15) Stb-Ceil, White 15 Cd 0.061 34 19.79 3 NW OFFICE AREA STWC 15 Stb-Ceil, White 15 Cd 0.061 21 19.72 4 NW OFFICE AREA STWC 15) Stb-Ceil, White 15 Cd 0.061 20 19.67 5 NW OFFICE AREA MEZZANINE HSW(15) H/S-Wall, White, Hi 15 Cd 0.082 30 19.61 6 NW OFFICE AREA MEZZANINE HSW 15) H/S-Wall, White, Hi 15 Cd 0.082 26 19.56 7 NW OFFICE AREA MEZZANINE HSW(110 H/S-Wall, White, Hi 110 Cd 0.197 19 19.54 8 --1 19.54 9 -- 19.54 10 ---_ 19.54 11 -- 19.54 12 ---- 19.54 13 -- 19.54 14 --_- 19.54 15 -- 19.54 16 -- 19.54 17 ---�� 19.54 18 -- 19.54 19 -- 19.54 - 20 -- 19.54 Farmer's TI EOLv Calc NAC, 6 CKT(20.4V Nominal).xls OUTPUT 6 NAC EXTENDER BATTERY CALCULATIONS CAPITOL ELECTRIC CO., INC. (503) 255-9488 Office, (503)255-1966 Fax JOB NAME: Farmer's TI ADDRESS: 6600 SW Hampton Street Tigard,OR 97223 DATE: 10/4/17 PANEL DESCRIPTION: NAC 1.1 PREPARED BY:Shane Tercek DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE QUANTITY CURRENT CURRENT CURRENT CURRENT NAC EXTENDERNr Potter PSN-106 Power Supply 1 0.06 0.060 0.200 0.200 CIRCUIT#1 ''' spare 0.000 mn� pini, m,r� rva 0.000 0.000 - iu ipl r 0.000 0.000 s y 0.000 -ii 0.000 0.000 " �c � r!� � 0.000 CIRCUIT#4r fi TOTAL 0.000 o , ) Whlk HSW 75 Cd H/S-Wall (H) 2 � � �i ,� �w 'u� 0.148 0.296 Whlk HSW 15 Cd H/S-Wall (H) 1 9tid rI(m Whlk HSWC 75 Cd H/S-Ceiling (H) 2 0.0820.082 Whik HSWC 30 Cd H/S-Ceiling (H) 2 0.148 0.296 , ,�,�"u�` ' ',°°; 0.102 0.204 Whlk HSWC 15 Cd H/S-Ceiling (H) 5 " L � I 0.082 0.410 Whlk STWC 30 Cd Strobe-Ceiling 2 0.085 0.170 Whik STWC 15 Cd Strobe-Ceiling 3 0.061 0.183 0.000 �i fl h�ll�k irui viii(( ��fi - ro ,r • irk 0.000 '`s" rN ' TOTAL 1.641 ���� l � m, , CIRCUIT#3 � rn � nw ~ Whlk HSW 110 Cd H/S-Wall (H) 2 !I ,. ;"oi n r • ' 0.197 0.394 Whlk HSW 75 Cd H/S-Wall (H) 5 """ 0.148 0.740 Whlk HSWC 95 Cd H/S-Ceilings (H) 1 , '" � � :"���,��� �ti�11� ��� � 0.176 0.176 0.000 Whlk HSWC 15 Cd H/S-Ceiling (H) 21 �°!u „ K' r p Ni Lam.?'. � � 0.082 0.164 Whik STWC 95 Cd Strobe-Ceiling 1 jib ' iii �i, ," � 0.163 0.163 Whlk STWC 30 Cd Strobe-Ceiling 2 ,! u,r , Whlk STWC 15 Cd Strobe-Ceilingi 0.085 0.170 1 :' • �i� gin' 0.061 0.061 0.000 t` ,Ii 1 IIS i 'r 7 TOTAL 1.868 CIRCUIT#4 s " , t fl • Whik HSW 185 Cd H/S-Wall (H) 1 �" " "; .w� �'! Tti ,'r 0.282 0.282 Whlk HSW 135 Cd H/S-Wall (H) 2r'9 "^'' °i, '` 0.242 0.484 H Whlk HSW 30 Cd H/S-Wall arm. ( ) 1Ll>'I»aN ,(1L� � i( 1 XIS 0.102 0.102 Whlk STW 30 Cd Strobe-Wall 1mss tl11vi � �� .!�� � ^: 0.085 0.085 Whlk STWC 15 Cd Strobe-Ceiling 3 °gib„ " mi ° 0.061 0.183 rG'i��n,r tiff w711W f mu,�e.. c&. 0.000 0.000 "' 0.000 iw 11 u , 0.000 i � TOTAL 1.136 Farmer's TI Batt Calc Potter PSN-106 NAC Panel (20.4V Nominal).xls Page 1 of 2 NAC EXTENDER BATTERY CALCULATIONS CIRCUIT#5 ku11d •IiNlii S NIPtin¶ � gaNgl ,. 0.000 Whlk HSW 110 Cd H/S-Wall (H) 2 „ iu��w .., ... . i 0.197 0.394 Whlk HSW 15 Cd H/S-Wall (H) 4 ur n ' �'�Iili 6Gm 0.082 0.328 - Whlk HSWC 15 Cd H/S-Ceiling (H) 1ap� u� � '�� �� 0.082 0.082 Whlk STWC 30 Cd Strobe-Ceiling 1 ,, ,uni W,i „ 0.085 0.085 Whlk STWC 15 Cd Strobe-Ceiling 2 � �i � °per"'l 0.061 0.122 0.000 0.000 0.000 TOTAL 1.011 CIRCUIT#6 uifl ,.,. ak al m,... i � p'....,.. id 0.000 Whlk HSW 110 Cd H/S-Wall (H) 2 p ° . ' ; 0.197 0.394 Whlk HSW 15 Cd H/S-Wall (H) 2 iii'<«' 0.082 0.164 Whlk STWC 15 Cd Strobe-Ceiling 3 ti ; rP 0.061 0.183 �������.� �.�a� �":u•, �: 0.000 0.000 u ilU�fii3 s � 0.000 0.000 0.000 ___ TOTAL 0.741 CAPITOL ELECTRIC CO., INC. (503)255-9488 Office, (503) 255-1966 Fax JOB NAME: Farmer's TI ADDRESS: 6600 SW Hampton Street Tigard,OR 97223 DATE: 10/4/17 PANEL DESCRIPTION: NAC 1.1 PREPARED BY:Shane Tercek DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE QUANTITY CURRENT CURRENT CURRENT CURRENT AUXILIARY DEVICES 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 STANDBY TOTAL CURRENT: 0.060 STANDBY HOURS: 24 STANDBY AMP HOURS: 1.440 NAC DEVICE CURRENT 6.397 ALARM TOTAL CURRENT: I 6.597 ALARM MINUTES: 5 ALARM AMP HOURS: 0.550 TOTAL CALCULATED AMP HOURS 1.990 APPLIED SAFETY FACTOR 1.20 MINIMUM AMP HOURS REQURED 2.388 _ SELECTED BATTERY SIZE 12 EACH 12 VOLT, 7 AMP HOUR BATTERIES Farmer's TI Batt Calc Potter PSN-106 NAC Panel (20.4V Nominal).xls Page 2 of 2 Wheelock° ExcederTM Series ii/ COOPER Notification EjetrEE.-"ZIT' Finally, Design and Safety Meet... �3a1`6'L If�f) p L M "m- Whama� ^40 m P .x„"m, „a. .l „�, v (A 0 i �I i F ani Description: The Wheelock®ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced Save up t0o in current draw* total cost of ownership. Installers will benefit from its comprehensive � � feature list, including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test . Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. -Save up to 1♦4% ** cost of installation. The Wheelock®ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single to Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings,can be set without the use of a tool and are located behind the appliance to prevent tampering. ka Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting1VDC Mltiple Voltages base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a till 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 10 8 Candela Settings*** it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if rs Univeal Mounting Base *** required. Wall models provide an optional locking screw for extra Ceiling and Wall secure installation, while the ceiling models provide a captivated Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. Environmentally Friendly tall Low Current Draw Compatibility and Requirements Synchronize using the Wheelock®Sync Modules or panels with,built-in Wheelock®Patented Sync Protocol -Compatible With UL"Regulated Voltage"using filtered VDC or unfiltered VRMS!input voltage Strobes produce 1 flash per second over the"Regulated.Voltage"range *Compared to competitive models **"Patented **Compared to previous models • NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed In bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT, VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Nofes' General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". -All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of.93%(±2%)UL 464(85%UL 1971). - •Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only), Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ►ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 gni 0.205 0.253 0.110 0.140 ►STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 ' 0.205 0.253 G 0.110 ii�liu,rll� �.� Horn Strobe Ratings per UL 1971 &UL 464 at 24 VDC UL Max Current*at 99 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC 0.HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 ►HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.125 UL Max Current*at 95 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 = 0.139 0.163 0.186 w,�� ,,T, 0.230 lr 0.272 0.122 0.153 d du..`a:a1 ya 'n�A� iro u''iln,. HSC 8.0-33.0 0.073 0.087 0.139 0.163 :. 0.230 0.272 0.122 UL Max Current*at 90 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 °iy;i 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 aa: 'i 0.120 Horn Ratings per UL 464 fi Model Regulated Voltage 99 dB 95 dB 90 dBit! p Range VDC HN 16-33.0 0.064 0.044 0.022 ,, HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.0111 7 ' ' fid" HNC 8.0-17.5 0.047 0.026 0.017 pi a o ,A * IA max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the,, UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units). For audibles the"max current is.usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings,see installation instructions. Specification & Ordering Information Strobe Sync w/SM, Mounting Model Candela DSM or 12/24 VDC* '11)) Options PS-6&PS-8 x Horn Strobes o 0 U) HSR 15/1575/30/75/95/110/135/185 X X ro UMB** O HSW 15/1575/30/75/95/110/135/185 X X o UMB** U HSRC 15/30/60/75/95/115/150/177 X X y. UMB** 0 HSWC 15/30/60/75/95/115/150/177 X X ro UMB** o Strobes v U 5 0 E STR . 15/1575/30/75/95/110/135/185 X X UMB** 143 STW 'p 15/1575/30/75/95/110/135/185 X X c6 UMB** E STRC 'r' 15/30/60/75/95/115/150/177 X X N UMB** 0 STWC C 15/30/60/75/95/115/150/177 X X UMB** tv Horn c i _ (perp R 0HNR 4ii° Thai a a 3rINwr'C h" X X UMB** HNW rIa IIo 1I , 4�� idiiia 'ti;u X X aj UMB** N HNRC �hIM� Ia 'iG�i�Piapu,u /� i9j�r�'!.,;{"',, ���, ,('.�. X X UMB*. CO V G 9..,.:.:...:. iH1:.C,�i.�uill��kii..i19,i�1��FD� ,r�.„SvV5;" ....,.,�,:ub co W HNWC 00 µl CpHIab U 7 -r' X X UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend { , HN —Horn:' ST =Strobe HS =Horn Strobe. ' C =Ceiling Mount € I,' W White «. Example 1: STRC Strobe', Red'Ceiling Mount : )1a Example 2:`HSR;=Horn Strobe, Red,Wall Mount ;;., '" Example 3: HSW,=Horn Strobe,White,Wall Mount ' Examp =t„ •Le WHSP, Nl w err a.. ,'''-'1,,,t:':.:fr;* :'''2, ' 4-.14'e.. t i ,t'''...7.':'; litli 0 C) h Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 troubleshooting and easy spot mounting options checking (wall models only) NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects,and.Engineers Specifications The notification appliances shall be Wheelock®ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn,strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6"D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63"D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain(1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 11/09 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. 4401 Wilson Boulevard,Suite 220 Long Branch,NJ 07740 Sarasota, FL 34243 Arlington,VA 22203 P:800-631-2148 P:941-487-2300 P:877-459-7726 F:732-222-8707 F:941-487-2389 F:703-294-6560 www.coopernotification.com 10111. Cooper Notification is Wheelock° i',1; SAFEPATH® WAVE COOPER Notification P POTTER PSN SERIES The Symbol of Protection POWER SUPPLY UL,cUL,CSFM Listed • PSN-64 has 6 amps regulated with 4 Outputs ► • PSN-106 has 10 amps regulated with 6 Outputs • Outputs Rated at 3 amps maximum each 3' • May be configured as up to three class"A"Style"Z"notification circuits • 3 amp,24 VDC programmable output power : • Supervised Battery Charger:27.3 @ IA(supports 7-55 AH batteries) mi • Easy to install cabinet with leveling mounts and key lock 011% • Wiring knockouts provided on sides and top of cabinet '40, • Two Trouble Relays(5A at 30VDC) General System Trouble(programmable for AC delay) Low AC Trouble with optional delay settings • Diagnostic LED's patent peadwg Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault(Amber),AC(Green),Battery Fault(Amber) • Trouble Memory feature captures troubles which have previously restored • Synchronized notification appliance circuits C US Potter/AMSECO®,Wheelock*,Gentex®,System Sensor LISTED lr� S2930 7315-0328.0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal Electrical Specs: Stock Number:3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 3006446 PSN-106 Black Enclosure • Standby Current 60 mA • Alarm Current 200 mA* *no external load Description The PSN series of notification power supplies offers reliable notification Sensor®strobe devices. Each output can be configured the same sync power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash. The panel will any derating. recognize the type of input being supplied and pass this through to the The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected and has a regulated 24 VDC output. In addition,the panel can charge on each output independently. up to 55 AH batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an for securing the door.Ample electrical knockouts are provided on the installer to review past troubles and make the necessary repairs.Each sides and the top, allowing the installer options for running wires and output has an LED to pin point the exact circuit where a problem may maintaining the correct separations. have occurred.Relays are provided for monitoring the general system The power supply offers an industry leading Quadrasync function that and AC failure. allows for multiple strobe circuits of different brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Potter Electric Signal Co.,LLC • St. Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REV C2 PAGE 1 OF 2 11/12 P POTTER PSN SERIES The Symbol of Protection POWER SUPPLY PSN-106 Wiring Diagram .° 120/240 VAC GND FAULT o Jumper Position DETECT ENABLE ON IIo sl 01 OFF 120VAC 50Hz-60Hz 240VAC 50Hz-60Hz Black Connect to separate White unswitched AC circuit Ground Status LED's O - -p�,� ONACI NAC2 NAC NAC4 NACS NACS DCPWR t AlI II o —p,...! 'S7 'SS r • 0 CO ]aaaaeaa_a]Ieaeaeaoa_] 0H N El o o aeaee sI COMM Fuse ...... II I o faeaeea]s2 ❑ ❑ a (47 ❑ o Neggga]53 0 0 ❑ Factory Installed o HOOP S4 Interconnect. AC Power o BOW ss ✓ Low Battery O • Gad Fault r Comm O o NUN'S6 la Bulk Options J1aaEl OOO,®e®. ® ��-- (�I ��il t O O NAC I! NAC2 SACS NAC4 SACS SACS DC PWR REF NI 7 IN2 O �� - LOW c _ + - + - * - + - + + - + MI +FOT; - +FOI IILLANC COM YNO NC COM NO Battery+ 1.J{ / Battery- -..w- •._- Common Ielays are Q ,2 Optional E.O.L. non-power limited. ° Reference E O.L. E O.L. DC Power Trigger Battery connect oa(non-power limited). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Use two(21 l2V batteries connected Lt seriessupply is triggered.There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further power supply shall operate on either 120 or 240 VAC input.The panel indication of the troubles present.The panel shall have selectable Trouble shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. housing up to 18 AH batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet. power without degradation overtime.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits ofstrobe appliances.The power supply shall synchronize system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit of the system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of Class AB operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864. In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above Thns(input tracking),Potter/AMSECO®sync, Gentex®Sync, System mentioned sync patterns as an input and pass this signal through and Sensor®Sync or Wheelock®sync. The LEDs shall provide indication synchronize the outputs to match the input flash pattern. of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 11/12 ': i. g / 7 ,� L -' NP • NP7- 12 NP7- 12FR Sealed Rechargeable Pe Lead Acid Battery •NOMINAL VOLTAGE: 12V •CHARGE RETENTION(shelf life) 12V, 7.OAh at 68°F(20°C): •NOMINAL CAPACITY: 1 month 97% 20 hr.rate of 0.35A to 10.5V 7.0Ah 3 months 8951s 10 hr.rate of 0.65A to 10.5V 6.5Ah 6 months 85% 'e'er• �� � 5 hr.rate of 1.19A to 10.2V 5.95Ah .004 1 hr.rate of 4.20A to 9.60V 4.2Ah •LIFE EXPECTANCY: 185± STANDBY USE 3 to 5 years •WEIGHT(approx.): 6.17 pounds CYCLE USE (approx.): 060~ 020 (2.80 kgs.) 100%depth of discharge 250 cycles 50%depth of discharge 550 cycles �Ae •ENERGY DENSITY(20 hr.rate): 30%depth of discharge 1200 cycles o1 g I Wil _ 1.49 WH/cubic inch(91.0 WH/liter) N •SEALED CONSTRUCTION: INCH = MM •SPECIFIC ENERGY(20 hr.rate): Can be operated in any position 250 6.35 13.6 WH/pound(30 WH/kg) without leakage. .185 4.70 .124 3.15 •INTERNAL RESISTANCE OF CHARGED •STANDARD TERMINAL: .098 2.49 BATTERY: Quick Disconnect.187 .031 ±,004 30 milliohms(approx.) or Optional.250 060 1.52 .031 0.79 +MAXIMUM DISCHARGE CURRENT •HOUSING MATERIAL: ABS Resin .020 0.51 WITH STANDARD TERMINALS: .004 0.10 40 amperes •OPTIONAL: Container and cover made from •MAXIMUM SHORT-DURATION Flame Retardant ABS DISCHARGE CURRENT: (UL94-V0/L.O.I.>28%) Dimensions 210 amperes •OPERATING TEMPERATURE RANGE: C'-'%' CHARGE 5°F to 122°F Ci w (-15°C to 50°C) ns W • rzs�,d o�w� P\ ('si ) DISCHARGE -4°F to 140°F [r,,I aa,y - i "°� DIMENSIONS:MM(INCHES) Ul listing pending-File No MH16464 ` t 5,,01TM ri—e°900--0 44 Power/Fu//Solutions la Publication No:US-NP7-12-02 •July 2005 DISCHARGE CHARACTERISTIC TEMPERATURE EFFECTS IN RELATION CURVES AT 25°C (77°F) TO BATTERY CAPACITY (V) (V) (0) 12V 6V 4V Battery Battery Battery NP temperature 25°C(1'"!°F) (A') i30 8.5�4.33--_- --■�, re' 120 CW9 1201 6.o" CO. ��—ice--" ``��\. , 4 100 CP _ o �,,"„ ,"' 005 h O1CP ti.0- 5.5-3.6) 1 80 it1.0- 5.0'3.33114 ,,'t„����CA.2C.°.t(AOD5CA; 6 021 Cr C O O 6CA y 4.0'1 4.5-3.0 ' �tCA., __ H 4D + ICA _�I� III 6a' 4.0..:.0) ._.'i"2CA LYI I- 20 �� _ ■ ,■■,........ a 3GA 1 2 4 8 8 10 20 40 60 2 4 0 8 10 20 -..1011111111111111110 I m n -20 -10 0 10 20 30 40 50 (°C) Discharge Time —� -24 14 32 50 68 86 104 122 (°F) 4 Temperature SELF DISCHARGE CHARACTERISTICS OPEN CIRCUIT VOLTAGE VS REMAINING CAPACITY (%) 100 14)D AT 25°C(77°F) 1 r J 75 — a.... z 18.0 •. E 50 E120°C(68°F) a � ..... Y._....__�� et 40°C(104°F) w I I 30°C(86 F) o°' , 25 - . ... - _.i_._.....__.._ 11.0 _.__ f 1 ( 0 ' 100. I 3 6 9 12 I 15 78 0 20 40 60 80 100 STORAGE TIME(MONTHS) REMAINING CAPACITY(%) CYCLE SERVICE LIFE IN RELATION FLOAT SERVICE LIFE TO DEPTH OF DISCHARGE m TESTING CONDITIONS:DISCHARGE CURRENT:0.1TC AMP.(F.V.1,711/CELL) aJ CHARGING CURRENT:0.09C AMP. °° CHARGING VOLUME:125%OF DISCHARGED CAPACITY Ze TESTING CONDITIONS:FLOATING VOLTAGE 2.25 TO 2.3011/CELL a WI%) AMBIENT TEMPERATURE:20°C TO 25°C(68°F TO 77°F) ? AMBIENT TEMPERATURE:20°C TO 22°C(64°F TO 72°F) 120 '"I, 1120 120 c5Iii a 60 i- 100%0.0,0. 50%D.O.D. 30%DEPTH OF DISCHARGE r 40 � 20 cc cr D 1 2 3 4 5 5.5 us a 20 d D LIFE(YEARS) 200 400 600 800 1000 1200 1400 NUMBER OF CYCLES When the battery will be used by current in excess of 3C,consult with EnerSys prior to use. CHARGING METHODS(At 20°C) Cycle use: Maximum charging current 1.75A Charging voltage 14.4 to 15.0V CAUTION *Avoid short circuit Standby use: Float charging voltage 13.50 to 13.80V *Do not charge in a sealed container. + EnerSys EnerSys EMEA Represented by: P.O. Box 14145 Brussels, Belgium 11er Reading, PA 19612-4145 Tel:+32(0)2 247 94 47 USA EnerSys Asia -"a""solr,rru a Tel:+1-610-208-1991 Guandong, China +1-800-538-3627 Tel:+86 755 689 9220 Printed in U.S.A. www.enersys.com ©2005 EnerSys.All rights reserved. Trademarks are the property of EnerSys and its affiliates unless otherwise noted. SYSTEM�... SENSOR ' . . • 4-Wire Photoelectric Duct Smoke Detector The InnovairFlex-Series are the only duct smoke fieN detectors flexible enough to fit configurations fromInnovr square to rectangular and everything in between. Features The InnovairFlex D4120 4-wire photoelectric duct smoke •Photoelectric,integrated low flow technology detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. •Air velocity rating from 100 ft/min to 4,000 ft/min(0.5 m/s to 20.32 This unit senses smoke in the most challenging conditions,operating m/sec) in airflow speeds of 100 to 4,000 feet per minute,temperatures •Versatile mounting options:square or rectangular configuration of—4°F to 158°F,and a humidity range of 0 to 95 percent(non- •Plug-in sensor offers superb false alarm immunity and the latest condensing).A plug-in sensor head offers improved false alarm sensor technology immunity and simple installation,testing,and maintenance.An improved cover design isolates the sensor head from the low-flow •Broad ranges for operating temperature(-4°F to 158°F)and feature for simple maintenance. humidity(0%to 95%non-condensing) •Patented sampling tube installs from front or back of the detector The InnovairFlex housing provides ample wiring space,a 3/4-inch with no tools required conduit knockout,and built-in short circuit protection to prevent damage to sensitive components during installation.High contrast •Increased wiring space with a newly added 3/4-inch conduit terminal designations make wiring easy.With its 2:1 sensor-to-power knockout capability,the power board of the D4120 may be used to monitor •One easy-access Test/Reset button and improved LED status a second sensor,D4S,simultaneously(i.e.,supply and return side). •Patented interconnect feature for multi fan shutdown As many as 50 InnovairFlex detectors can be interconnected.When one unit senses smoke,all interconnected detectors will switch •New high contrast terminal designations their relays;only the detector sensing smoke will go into alarm,thus •Built-in short circuit protection from operator wiring errors pinpointing the fire source. •Field selectable settings for configuring the detector An easy-access Test/Reset button makes it possible to test the unit •Two DPDT Form-C relay contacts with the cover on.Three DIP switches can be used to configure field •24 VAC/DC or 120 VAC selectable settings:cover tamper delay,number of sensors to be controlled,and shut down on trouble option.Each power board •Backward compatibility with existing Innovair products,including has two LEDs that can be used to indicate the status of connected remote accessories sensors,and a quick reference imprinted on the cover explains the LED status indications(Standby,Maintenance,Trouble,and Alarm). The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring.The new InnovairFlex product line is compatible with all previous Innovair Agency Listings models,including remote test accessories. WARNING:Duct smoke detectors are NOT a substitute for open • '' MSFM U� 414f; area smoke detectors;NOT a substitute for early warning detection; LISTED APPROVED approved NOT a replacement for a building's regular fire detection system. 5911 3029700 3242-1653207 2202 Refer to NFPA 72 and 90A for additional information. InnovairFlex'"Duct Smoke Detector Specifications Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlex""D4120 Photoelectric Duct Smoke Detector.The detector housing shall be UL listed per UL 268A specifically for use in air handling systems.The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular.The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute(0.5 to 20.32 meters/second).The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors.The detector shall be capable of providing a trouble signal in the event that the front cover is removed.It shall be capable of local testing via magnetic switch,test button on the cover,or remote testing using the SSK451 Multi-Signaling Accessory or the RTS451 KEY Remote Test Station.Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. • Physical Specifications Size:(Rectangular Dimensions) 14.38 in(37 cm)Length;5 in(12.74 cm)Width;2.5 in(6.36 cm)Depth (Square Dimensions) 7.75 in(19.7 cm)Length;9 in(22.9 cm)Width;2.5 in(6.35 cm)Depth N Weight: 2.5 lbs(1.14 kg) Operating Temperature Range: D4120&D4S:-4°to 158°F(-20°to 70°C); D4P120:-40°to 158°F(-40°to 70°C) Storage Temperature Range: D4120&D4S:-22°to 158°F(-30°to 70°C); D4P120:-40°to 158°F(-40°to 70°C) Operating Humidity Range: 0%to 95%relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/min(0.5 to 20.32 m/sec) Electrical Ratings Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 HF max. 270 pF max. N/A Reset voltage: 3.0 VDC min. 2.0 VAC min. 10 VAC min. Reset time:(with RTS451) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time:(by power down) 0.6 sec.max. 0.6 sec.max. 0.6 sec.max. Power up time: 35 sec.max. 35 sec.max. 35 sec.max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements:(Using No Accessories) Max.standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max.alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Contact Ratings Alarm initiation contacts:(SPST) 2.OA @ 30 VDC(resistive) Alarm auxiliary contacts:(DPDT) 10A @ 30 VDC(resistive);10A @ 250 VAC(resistive);'/2 HP @ 240 VAC;'/a HP @ 120 VAC Note:Alarm auxiliary contacts shall not be connected to initiating circuits of control panels.Use the alarm initiation contact for this purpose. Supervisory contacts:(SPDT) 2.OA @ 30 VDC(resistive);2.0A @ 125 VAC(resistive) Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA151/APA451 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z 0 mA n/a 12 mA Max. RTS151/RTS151KEY 0 mA/12 mA n/a 12 mA Max. RTS2/RTS2-AOS 3.OmA max 16 mA Max. with strobe:55 mA max;without strobe 30 mA max Note:Any combination of accessories may be used such that the given accessory loads are:110 mA or less at the Aux output,and 50 mA or less at the Alarm output Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector.The tube locks securely into place and can be removed by releasing the front or rear locking tab(front locking tab shown below right). �` a d a'. . oiti� .'. , -,-,4411:-:-..: lif, ,..-11.v.:: = — 1 �a � �� m�� E� ¢z� " li illi :32-4, a liJi. ii . , uirr`aa` °1iiiilo= nq gg A05-0419-002