Plans (62) OFFICE COPY ' ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A t. AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN . k EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING SFF 2 1 1017 EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE �`'i #` GALV GALVANIZED HAZARDS PER ART. 690.17. `I, ,iI� f °_,a c f t.'s`., GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). OFFICE COPY Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR CITY OF TIGARD kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC REVIEWED FOR CODE COMPLIANCE LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN Approved I • (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY OTC: NEUT NEUTRAL UL LISTING. F NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE Permit#: ms-1-ao i"7 - no 3 6a OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE Address: i t33 R A Sc,'i--S u,N,c PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. Suite#: PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE By: ....=:t- Date: 9 -a-7 _ i SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT . W WATT PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT PV2 SITE PLAN ' ,,,_ PV3 STRUCTURAL VIEWS AND CALCULATIONS $ `' ` CutsheetsPV4THREE AttachedLINEDIAGRAM LICENSE GENERAL NOTES OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC s RGC, CGC1 AND 2012 IBC. >' M 2. ALL ELECTRICAL WORK SHALL COMPLY WITHrya � 0 THE CURRENT NATIONAL ELECTRIC CODE AS Si kori h center 0c;) ` • AMENDED BY THE OREGON ELECTRICAL SPECIALTY 0 � CODE. ore ' MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Tigard - REV BY DATE COMMENTS EITICEI DATE COMMENTS ©©© UTILITY: Portland General Electric CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-9703003 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE NANCY FRASER Nancy Fraser RESIDENCE Cody Anderson -,- s 5 L . BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13386 SW SATSUMA 4.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTSORGANIZATION, EXCEPT MODULES: BEAVERTON OR 97007 THE SALE AND USE OF INCONNECTION RESPECTIVE�TM (16) TRINA SOLAR # TSM-300DDO5A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE PERMISSION OF TESLA INC. ABB ; PV1-3.6—OUTD—S—US—Z—A COVER SHEET PV 1 9/19/2017 PITCH: 26 ARRAY PITCH:26 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories 0 I ---\ I ---, i D ; : ( Inv ) Front Of House LEGEND • 0 (E) UTILITY METER & WARNING LABEL _2" FSB ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS Cl —sMP ® ® I_DC -.i DC DISCONNECT & WARNING LABELS W w AG AC DISCONNECT & WARNING LABELS o c o o c �-I oo rn ® o o c - o 0 DC JUNCTION/COMBINER BOX & LABELS (E) DRIVEWAY C/) OD DISTRIBUTION PANEL & LABELS C 0 0 C c cn LC � LOAD CENTER & WARNING LABELS ® ® ® ® O DEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN A v STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r„---i it ;" INTERIOR EQUIPMENT IS DASHED L-J SITE PLAN N TOTAL ARRAY AREA (SF): 288 Scale: 1/8" = 1' �, TOTAL ROOF AREA (SF): 1852 W `+ E TOTAL ARRAY AREA IS a 15.53 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA . ��� �� " s CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9703003 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE NANCY FRASER NancyFraser RESIDENCE CodyAnderson INIMMI BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN MOLE OR IN CompMount Type C 13386 SW SATSUMA 4.8 KW PV ARRAY T 5 L n PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULE �' BEAVERTON,TOR 97007 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-300DDO5A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. ABB # PVI-3.6-OUTD-S-US-Z-A SITE PLAN PV 2 9/19/2017 1444. (E) 2x4 0 ---'' \ 6'-4" /- 5-4" / 5-5"-- 1'-z'1 (E) LBW SIDE VIEW OF MP1 NTS PRE-MANUFACTURED TRUSS A STRUCTURE MEETS THE PRESCRIPTIVE REQUIREMENTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES OF THE OSSC SECTION 3111 LANDSCAPE 72" 24" 39" 0" STAGGERED PORTRAIT 48" 20" 64" 0" TOP CHORD 2X4 @ 24"OC ROOF AZI 180 PITCH 26 STORIES:2 ARRAY AZI 180 PITCH 26 BOT CHORD 2x4 @24"OC Comp Shingle 09.192017 X ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS ANDY IS ALONG RAFTERS. Version#69.5 DESIGN SUMMARY i' Joi3te,Spec Design CI a Design Code ASCE 7-10 PV MODULE Importar`ce,Factor = I 1.0 5/16" BOLT WITH INSTALLATION ORDER ultimate Wind Speed V Ult 95 mph ' Fig 1609A Exposure, to V ` Section 26 7 FENDER WASHERS LOCATE RAFTER, MARK HOLE Ground Snow Load pg 25 0 psf ASCE Table 7-1 ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT F ` �_ HOLE. ZEP ARRAY SKIRT (6) tli : ,. '� (4) (2) SEAL PILOT HOLE WITH ° 3 � � ,'.,_:illi �� ��� ���., ��� POLYURETHANE SEALANT. MP Name MP1 ZEP COMP MOUNT C o Roofing Okn tt-0 - ZEP FLASHING C ��.]� �� � l[L• t / Standoff Comp Mount Type �.���� �r (3) INSERT FLASHING. & titch. 0 ���Gm � ii A SLIRLL:PV 25.0 psf r�� rv_ ��'j u— / CI st 2LL Not[-PV 25.0 psf ' (E) COMP. SHINGLE !IW (4) PLACE MOUNT. (E) ROOF DECKINGAgillik‘MIIIII (5) INSTALL LAG BOLT WITH 'i , ortin fift4 ' yob '7Y-1'r' MP Name MP1 5/16" DIA STAINLESS (5) SEALING WASHER. AX—Spading 7 STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES - INSTALL LEVELING FOOT WITH y X Cantilever 24" WITH SEALING WASHER (6) _ oach ., " _BOLT & WASHERS. - 'I-Cantilever NA (2-1/2" EMBED, MIN) ., s > 48„ _ '. - q :° X-Cantilever 20" (E) RAFTER 1 STAN DOFF a V-Spacing .:164" ' $1Y-Cantilever NA = ° Layout g@f€fid` �` Scale: 11/2" = 1' X and Y are maximums that are always relative to the structure framing that supports the PV. Xis across rafters and Y is along rafters. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9703003 0 0 PREMISE OWNER: DESCRIPTION: DESIGN:CONTAINED SHALL NOT BE USED FOR THE NANCY FRASER Nancy Fraser RESIDENCE Cody AndersonT - 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13386 SW SATSUMA 4.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS Moon BEAVERTON, OR 97007 ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-300DDO5A.18(II) SHEET: REN DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME PERMISSION OF TESLA INC. RJVERTER. ABB # PVI-3.6-OUTD-S-US-Z-A STRUCTURAL VIEWS AND CALCULATIONS P V 3 9/19/2017 / / • GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:NoMatch Inv 1: DC Ungrounded # OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: INV 1 —(1)ABB 1 PVI Inverter; Zigbee 3600W, 2ABELA —(16)TRINA SOLAR TSM-30DDD040M ,Bl RGC, CGC1 33 892 205 AFC! nverter; Zigbee 3600W, 277V/240V/208V, 96%/96%/96% PV Module;30 ,270.6W PTC,40MM,lBillk Frame,MC4,ZEP,1000V,Wht BckSht Underground Service Entrance INV 2 Voc: 39,g Vpmax: 32.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 225A MAIN SERVICE PANEL (E) 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! Inverter 1 IND 200A/2P ® ABB A DC+ Vstart = 200V PVI-3.6—OUTD—S—US—Z—A I Dc- MP 1: 1x8 --°R (E) LOADS r 1 EGC W—ij A L1 L2 , 290V I I � �� DC+ I ea 20A/2P EGC/ ---- DC+ SJI ZDC+ Vstart= 200V CO IO ��B GEC 1 N __ DC- J C- 'p MP 1: 1x8 cli �-B 1 I GND I---_EGC_ 111111--- _ GC I J' (1)Conduit Kit; 3/4" EMT N EGC/GEC - z-z C, — GEC r 1 TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I II I I I I I I I I j Voc* = MAX VOC AT MIN TEMP POII-(1)SBreaaker,,D2OA/2P, 2 Spaces PV BACKFEED BREAKER /A C DC —(2)Grouid Rod /-� 5/8 x 8, Copper 1 1 1 AWG#10, THWN-2, Black AWGX110, PV Wire, 600V, Black Voc* =354.38VDC Isc =9.64 ADC 1 O L0-(1)AWG#10, THWN-2, Red 5H(2) (1)AWG #10, THHN/THWN-2, Green EGC Vmp =260.8 VDC Imp=9.19 ADC (1)AWG#10, THN-2, White NEUTRAL Vmp =240 VAC Imp=16 MC (1)Conduit Kit; 3/4" EMT -(1)AWG#8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4" EMT (2)AWG#10, PV Wire, 600V, Black Voc* =354.38 VDC Isc =9.64 ADC O (1)AWG#10, 1HHN/THWN-2,Green EGC Vmp =260.8 VDC Imp=9.19 ADC ISL(1)Conduit Kit; 3/e EMT I i CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9703003 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE NANCY FRASER Nancy Fraser RESIDENCE Cody Anderson T -- S L R BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 13386 SW SATSUMA 4.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NODULES: BEAVERTON OR 97007 ORGANIZATION, EXCEPT IN CONNECTION WITHs THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-300DDO5A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A THREE LINE DIAGRAM PV 4 9/19/2017 • Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC - A (AC)(P01) WARNING (POI) Per Code: OPERATING CURRENT Per Code: Per Code: MAXIMUM AC INVERTER OUTPUT IFC 605.11.1.4 - v NEC 690.54 NEC 690.64.6.7 OPERATING VOLTAGE CONNECTION OT Label Location: q© OVERC RRETNT' PHOTOVOLTAIC DC (DC)(INV) DEVICE DISCONNECT Per Code: NEC 690.14.C.2 �- -° -�- "` Label Location: WARNING (AC) (P01) Per Code: Label Location: ELECTRIC SHOCK HAZARD NEC 690.17 4 �+ DC INV Label Location: DO 4OTT3UCHTERM{ S ( ) WARN V ( )( ) TERMINALS ON BOTH LINE AND Per Code: MAXIMUM POWER- (DC) (INV) LOAD (D S AY BE EN 'I E ELECTRIC SHOCK HAZARD POINT'CURRENT(Imp)�A THE DC CONDUCTORS OF THIS NEC 690.35(F) Per Code: IN THE OPEN POSITION�tN MAXIMUMPHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POWER- v NEC 690.53 ' POINTT VOLTAGE TAGE(Urnp}� - UNGROUNDED AND INVERTER IS MAY BE ENERGIZED MAXIMUM SYSTEM v UNGROUNDED VOLTAGE(Voc) SHORT-CIRCUITA CURRENT(Isc) Label Location: (AC) � Lab PV SYSTEM DISCONNECT FOR UTILITY OPERATION Label Location: WARNING (DC)(CB) ELECTRICAL SHOCK HAZARDPer Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING: ELECTRIC SHOCK DC VOLTAGE IS HAZARD.DO NOT TOUCH NEC 690.17.4; NEC 690.54 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT WARNING (DC) (INV) MAXIMUM AC Per Code: OPERATING VOLTAGE', - V ELECTRIC SHOCK HAZARD IFA GROUND FAULT IS'INDICATED NEC 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS ' NEC 690.64.6.4 Label Location: PHOTOVOLTAIC SYSTEM AC PHOTOVOLTAIC AC (AC) (P01) C(C):CCon Disconnect dt DISCONNECT Per Code: (CB): Combiner Box NEC 690.14.C.2 Label Location: (D): Distribution Panel (DC): DC Disconnect CAUTION (D) (P01) (IC): Interior Run Conduit Per Code: PHOTOVOLTAIC SYSTEM (INV): Inverter With Integrated DC Disconnect ) J CIRCUIT IS BACKFED NEC 690.64.6.4 (LC): Load Center (M): Utility Meter (P01): Point of Interconnection Label Set 0 ZS Comp Edge Zone Calculations 1 of 4 • ZS Comp Edge Zone Calculations 2 of 4 e alar 3/26/15 a Sot 3/26/15 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing= calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Load Duration Wind Snow € 40 design load landscape= 15.35 27.64 27.64 psf o � Uplift= 656 lbs N/A design load portrait= 12.28 27.64 27.64 psf Lateral= 357 lbs 290 lbs '' 85818 note:use 10 psf minimum Down Force= 1074 lbs 771 lbs Snow Calculations y To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment Spacing Calculations °'0.,,y ;art. Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 Uplift Spacing x /16 degrees. Allowable Uplift Load FOR PAGES1-4 uplift spacing= Ground Snow Load= 30 psf module length or width x design load Roof Pitch Wind Uplift Calculations 14 30 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf p=qh GCN (snow load spread over the length of the rafter) qh=0.00256 K,K21 Kd V2 I Down Force Load Roof Pitch Basic Wind Speed= 120 mph Combinations: 14 30 Exposure= C Roof Zone= Edge Zone D+S= 31.16 25.10 psf Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof Kit= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.75S_ 31.59 9,ipsf Vorst Case Roof Pitch= 14 degrees lc= 0.85 from Table 6-4 a Roof Height= 30 GCN landscape=-1.6 Allowable Spacing for Down Force Jscape effective area= 13.0 ft2 GCN portrait=-1.5 771lbs in lortrait effective area= 21.7 ft2 landscape down force spacing = 39"x 31.91psf x 144 ft2 =89" Piandscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf 7711bs in portrait down force spacing= 65"x 31.91psf x 144 ft2 =53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf lb landscape uplift spacing = 39 6 26.73 psf x 144 ft2 = 87" portrait uplift spacing = 65"656 25 89 psf x 144 in =56" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 ZepSotar 3/26/15 Z p to 3/26/15 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load Maximum Uplift Pressure Landscape= -27.73 lateral spacing= module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf p,=Cs pf Roof Pitch= 31 45 degrees landscape module spacing = -1.4545 x 31.91 psf+120.7273 = 74" pf=0.7CeC1Ipg Ce= 0.9 C,= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing =-0.8182 x 31.91 psf+79.909 = 54" I= 1.0 p5= 16.1 10.2,psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" 30° 27° 30° Lateral Force Component Lateral 74" 4r, 4 ,, Down Force Load Roof Pitch ' Module Deflection 74" 54" Combinations: 27 30 31 45 D+S= 13.50 '`14.43 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.75S 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 2901bs in landscape lateral spacing= 39"x 14.49 psf x 144 ft2 =74" 2901bs in portrait lateral spacing = 65"x 14.49 psf x 144 ft2 =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2901bs in • portrait lateral spacing= 65"x 13.50 psf x 144 ft2 =48" '"r,$olarCity ®pSolar Next-Level PV Mounting Technology +$OlafClty ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs , Leveling Foot [ lo tirmaxr zep =w ,�, �,r vst&�yatia Part No.850-1172 ETL listed to UL 467 I r 3 :',,..-----::::,,,,,i,:,„,,,,,4,,, '11:4'77;:::,, 41.7. "---,1_,_,I,..,,p,„: ..,..,.,,,,„,_ ,,,_" , ' t 1, I - Yap Orawe _ ^° " r e ar, s+�t 41 "WrComp Mount ��� _ Part No.850-1382 Listed to UL 2582 Iii, .iihrt, Mounting Block Listed to UL 2703 OOMPgT�e __ ,�?®`� Description PV mounting solution for composition shingle roofs "`j FA Works with all Zep Compatible Modules °0Mp0s� Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 17031111111111111i Ili( I • Wind tunnel reportto ASCE 7-05 and 7-10 standards11.;„...- .• -.1111/ik • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps zepsolar.com Part Nos.850-0113,850-1421, zepsolar.com L50eo0,L 567 Listedd 156 to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warrantyfor each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Additional highlights Solar inverters — RS-485 communication interface (for connection to laptop or data logger) �, 1_,-(,,,,:',..,,j""" Available with the optional VSN300 Wifi Logger Card for easy and affordable wireless monitoring �.� . = — Compliant with NEC 690.12 when used with ABB's Rapid Shutdown device — Comes standard with DC Arc Fault -" € Circuit Interrupter(AFC!)to complylnio 4-$11%,,-.4 with NEC 690.11 € rte''`I „mss Technical data and types ra' ' Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US General specifications = - € 3300 Nominal output power 3000W 3600W W 3800W 4200W 3000 3300' • 3300 3600 - 4000 . 4000' 3300 4200 4200' 4200 4600' 4600' Maximum output power wattage w W w w w W w w w W w w ' 4 ''4 .; Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V InPk1t etre ) Number of independent MPPT channels 2 2 2 2 royr, r€ , Maximum usable power for each channel 2000W 3000W 3000W 3000W f Absolute maximum voltage(Vmax) 600V Start up voltage(Vstart) 200V(adj.120-350V) . " Full power MPPT voltage range ..._, 160-530V • 120-530V 140-530V ... 140-530V Operating MPPT voltage range 0.7 x Vstart 580V(>_9oV) Maximum current(Idcmax)for both MPPT in 20A 32A 32A 32A .:1---C1/'r, ":,....11,11.28:): parallel... ... ...._.. €€ r Maximum usable current perchannel 1OA 16A 16A 16A el12 5A = 20 OA 20 OA 20 OA Maximum short circuit current limit per ,�{` channel - ..... 4 a, Number of wire landing terminals per channel 2 pairs .1110:a ' Array wiring termination Terminal block,pressure clamp,AWG20 AWG6 rr Output side(AC) Grid connection type 10/ Split- 10/ 10/ Split- 10/ 10/ Split 10/ 10/ Split 10/ .�.. . .. 2W PJ/3 W 2W _ 2W 0/3W 2W 2W.....l...PJ/3W 2W 2W 0/3W • ...2W...._. Adjustable voltage range(Vmin-Vmax)(V) 183- 211- 244- 183-2211- i 304- 183- 211- 344 183- 211- 244- 228V 264V 304V 228V 264V ; 304V 228V 264V 304V 228V 264V 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(la,m°.) 14.5A i 14.5A , 12.0A i 17.2A 16.0A 16.0A i 16.0A 16.0A 16.0A : 20.0A 20.0A 20.0A Power factor >0.995(adjustable to±0.8) This family of single-phase string The high-speed MPPT offers real- Highlights Total harmonic distortion at rated power <2°' inverters complements the typical time power tracking and improved — Single-phase and three-phase output Grid wiring termination type Terminal block,Pressure clamp,AWG20AWG6 number of rooftop solar panels energy harvesting. grid connection Input preteetiori devices .. Reverse protection Yes enabling homeowners to get the most The flat efficiency curve ensures high- — Wide input-voltage range for Over voltage protection type Var€stor,2 for each channel efficient energy harvesting for the size efficiency at all output levels allowing increased stringing flexibility and PV array ground fault detection Pre start-up R°„and dynamic GFDI(requires floating arrays) of the property_ a consistent and stable performance energy harvesting Output protection devices across the entire input voltage and — The high-speed andprecise MPPT Anti-island€ng protection Meets UL1741/IEEE1547 requirements p gOver voltage protection type Varistor,2(L L/L-G) This Inverter offers a dual input output power range. algorithm offers real-time power Maximum AC OCPD rating 20A 20A i 15A • 25A 20A 20A 20A l 20A 20A 25A 25A 25A section that processes two strings The transformerless operation gives the tracking and improved energy flioiency "" Maximum efficiency y 96.9% 97% 97% 97% with independent Multiple Power Point highest efficiency of up to 97.0 percent. harvesting CEO efficiency 96% Tracking(MPPT). The wide input voltage range makes — Outdoor NEMA 4X rated enclosure et'atieg performance This is especially useful for rooftop the inverter suitable to low-power for unrestricted use under any Nighttime consumption <0 6W„ms installations with two different installations with reduced string size. environmental conditions Stand-by consumption <BWa Oommuntoation I orientations from two sub-arrays This rugged,outdoor inverter has — Integrated DC disconnect switch User interface 16 characters x 2 lines LCD display oriented in different directions,or been designed to be a completely in compliance with international Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt.),VSN300 Wifi Logger Card(opt.) ..,Environmental unbalanced strings(for example:East sealed unit,to withstand the harshest Standards(-S Version) Ambient air operating temperature range 13°F to i 140 F(-25°C to 60°C)with derating above 122°F(50°C) and West). environmental conditions. Ambient air storage temperature range ............. -40°F to €176°F(40°C to 480°C) The dual-input sections with Relative hum€dity 0-100%RH condensing Acoustic noise emission level <50 db(A)@1 m independent MPPT enable a more AL 11 ID Maximum operating altitude without derating 6560ft(2000m) optimal energy harvesting condition. P vier andproductivity Cepabil'to enabled at nom nal AC voltage and th suffice t DC powers ailabie. for a better world'' 2 ABB solar inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD Block diagram of F'VI-3.0/3.6/3.814.2-TL-t3UT'D Support and service For more information please contact ©Copyright 2015 ABB.All rights „, ,,,� ,oCP&', LINE PARALLEL ABB supports its customers with a your local ABB representative or visit: reserved.Specifications subject to „,�,,,lb ❑' ❑ ❑ ' ❑ ',_'�' "" dedicated,global service organization g ■ than e without notice. " ■" www.abb.com/solarinverters 11 „ n more than 60 countries,with strong a } a gq,1 '''?t v „,,,_,0 ❑ o o o �!, �� •�. ��� IIII . r ■ regional and national technical partner ' „ 1 www.abb.com t____ networks providing a complete range of ri _ AROi I pc o`&, lite cycle services. ,;, V .22,,,,,, ittiu M _ rEa CURRENT a „z rvz ,rvz , i irvz Z ■ -2„ ,__1 , ■.,ra CC w n i . RTN TUVRheinlend WIRING BOX "-` t„C rv,nol•• oC)0 ,,,, .,.. i_..., 5 X COri� }-'t G6YlYR ■« C US � US DETECTION Y l'i ■ This inverter is marked with one of the m no nn,„«LR n ■ two certification marks shown here(TuV t. or CSA). 'Remote control function not available on-A version ' PV{-4.�OUTD-SUS, PVI,. 2-OUTD•US s : ,. AF@Yd:__,._,,, = nom .. / __ r ,manna U4b tUW 2G% 3M6 Mtr6. So% sure 74k &H6 �99% lUU4Bropy %'Wti9tatl OUIPat Pt._ - „. ,„o,.,, o ` ' rota*.. w lsMtN,beHn Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-QUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mechanicatapecifeatiorts , Enclosure rating,,.,......- ..._ NEMA 4X ..._ Cooling Natural convection DimensionsHxWxD 33.8x128x87in(859x325x222mm)' Weight ..... .... ......... .... ......... ..... .............. ..... <47 31b(21:3kg)' ........... .... ..... Shipping weight ............ ......... ...... ._._.......... ..._...... ....__.... <601b(27.0kg)2 ............... ..,............... Mounting system pWall bracket ............. ..... ...,. ......._. p... .... u .. . ...... Bottom:(2) re drilled opening for�inch conduits and concentric markings for 1 inch (both sides)and 11/2 inch conduit(DC side only) Conduit connectionsz Sides:(2)pre-drilled opening for 3 inch conduits with concentric markings for 1 inch (both sides)and 1/o inch conduit(DC side only) Back,(2)concentric markings for 3 inch and 1 inch conduits - .................. ... DC switch rating(per contact)(A/V) 25/600 _Safety and✓*ronmpliance Isolation level Transformerless(floating array) Safety and EMC standard UL1741,UL1741SA)draft(,IEEE1547,IEEE1547.1,CSA-C22.2 N.107.1 01 tj1' :UL 16996,FCC Part 15 ClassB...., Safety approval °CSA..or cTUVw .. ... .. Regional Compliance Rule 21,HECO,NEC 2014 690 11 NEC 2014 690.12 with ABB Rapid Shutdown device Avelabta,models. '. , With DC switch,wiring box,arc fault detector and PVI-3.0-OUTD-S PVI-3.6-OUTD S PVI-3.8-QUTD S PVI-4.2-OUTD-S- ' interrupter US-A US-A US-A US-A 2.When equipped with optional DC switch and wiring box. All data is subject to change without notice Power and produrctivity AL 11 ID for a better world'' Product flyer for PVI-3.0/3.6/3.8/4.2-TL-oUTD I ABB solar inverters 3 ` MonoMulti Solutions Trfina mount FRAMED 60-CELL MODULE t �,�...... ._«._,_" ""...........:... .,,...W PRODUCTS POWER RANGE THE TSM-DD05A.18(Q) I 280-305W ELFCTR CA DATA(STC) rPeak Power Watts Pmax(Wp)` 275 280 285 290 295 300 305 Trin a m o u nt , ,* ,PowerOutputTolerance•Pewx(W) 0,--+5 y ,y €?IMENS GNS OF P`J IzAOGtILE(mmiinches) Maximum Power Voltage-Vmre M 31.4 31.7 31-8 32.2 32.5 32-6 32.9 {,. 391/37.0 Maximum Power Current-Inver(v) 8.76 8,848.97 901 9,0B 9.19 928 ' ' t -� ►. Ii- k '14)h MODULE D( ! R Open Circuit Voltage-Von M 38.7 39.0 393 39.5 39.7 39.9 40.2 E..®�j 11 _ I Q ShottCircuitCurrent lsc(A). 9.26 935 '9.45 930 950 9.64 9.72 NdTenmre Module Efficiency rt, 16.8 17.1 17.417.718.0 18.318.6v (%) $ STCI d 1000W/',Cell Temperature 25'C,Air Mass AM 1.5. ,� ,�,-�,�, _.. qr1100 'Measuring tolerance.-13%. .. _♦-T.:..}y,,..,....---+i*---�d�....r....- [i:£`PoCAt.DATA(NOCT) ra 1OC"I Y TALLINE M: ULE At _e 0 ®rn io Maximum Power-Pmnx(Wp) 205 209 212 216 220 223 227 _ ...... '.iiir Masa7num Power Voltage-um.M 29,2 29A :293 ; 29,9 - 30,2 30,4 308 000312 I. Maximum Power Current Imre(A) 7.02 7.10 7.17 7.23 7.28 7.35 7.42 o oa3 whom_a Open Circuit Voltage-Vac M 36.0 36.3 36.6 36.7 36.9 37.1 37':3 P OUTPUT RANGEi e \ Short Circuit Current-Isc(A) 7.48 7.55 7.63 7.67 7.71 7.78 7.84 oa Ba =,-,I , �� NOCT:Irradiance at 800W/m2,Ambient Temperature 20"C,Wind Speed l m/s. Maximize limited space with top-end efficiency _ __ _____ yi, 40/1.57 992/39.1 �+F 2 MECHANICAL DATA ' y =Up to 18F)W.,2rnpower dens ty BackV ew ty •l_ow thermal coefficients f().greater energy production at high '°' Solar Cells Monoc stalline 156.75 x 156.75 mm(6 inches) ;perating temperaturesC:11 o 64AXIN . FF Ci C 41� CeD Orientation 60 ceRfRN 301 J Module Dimensions 1650 x 992 x 40 mm(65.0 x 39.1 x 1.57 inches) 11/0.43 on ,cant Weight 19.6 kg(43,1 Ib) ighly reliable due t( stringent quality central , _ ._ ,ate 6\1r c Glass 3.2 mm(013 inches),High Transmission,AR Coated Tempered Glass s 9 =Over 30 in hou e tests(UV,TC,HE,and many more) '''''''.;;POSITIVE G) RA •In-house testing goes wet beyond certification requirements Backsheet White •PIl resistant Frame •10[)%El.double inspection Anodized Aluminium Alloy 1 . J-Box IP 65or1P67 rated ' J_ Frame Foundedrvhem 1997,Irina Solar is the wxt sol s leading c - a Cables - Photovoltaic Technology Cable 4.0mm'(0.006 inches'), comprehensive solutions provider for solar energy,we 35/1 3e believe Jose cooperation with our partners is critical I to success. ma Solar now distributes is PVproducts - Certified to withstand the most challenging (A-A) 1000mm(39.4 inches) to over 60countries all over the world.Trine isable to ' '^V environmental conditions 1 I-V CURVES OF PV MODULE(305W) Connector i MCA provide exceptional service to each customer in each marketands.applementour innovative,reliable •2400 Pa wind load itior', vies products with the backing of Trina as a strong, ,owwam, Fire Type UL 1703 Type 2 for Solar City bavkabe partner.We areommitted to building `5400 Pa Snow loud c strategic,mutually beneficial collaboration with •35 mm hail stones at 97 km/h installers,developers,distributors and other partners. 2 It 3 a ` TEMPERATURE RATINGS MAXIMUM RATINGS Comprehensive ProCliictsV ., NOCTiNominaioperanng Cell Temperature) 44°C(±2'C) Operational Temperature 40-+85°C And System Certificates 441111 .0 a 20 30 90 50 vaweM iemperatateGaaffxJentoEPNax 0.3995lC MaxmamSYstemVulpge 1 N3UtsC(( EC3 I EC61215/I EC61730/U I.t 703/IEC6':701/1EC62716 . I ISO 90011 Quality Management System P-V CURVES OF PV MODULE(305W) Temperature Coefficient of Voc -0.29%/'C ' 11300VDC(UL) ISO 14001:Environmental Management System 000wrm, 'Temperature Coefficient ofhr €';0.05961°C Max Series Fuse Rating 5A 15014064:Greenhouse gases Emissions Verification --- ___-- aoo (DO NOT connect Fuse n Combiner Box with two or more strings m OHSAS 18001:Occupation Health and Safety am --- BOOW/^''-- --- - parauel connectonl Management Systen, LINEAR PERFORMANCE WARRANTYallai. aoo 10 Year Product Warranty 25 Year Linear Power Warranty )3/ WARRANTY PACKAGING CONFIGURATION xis �. (( '''9''''''''''''' t fi a, a y--'`�F >< 10 year Product Workmanship Warranty Modules per box:30 pieces p, A 3i r a t o f°'»Trrna 5o o o m o k, 0 Voltage(V) IS(�,.. � • PV CYCLE '25 Year linear Powee Warranty Modules per 4q.erntta€ner:840 pieces Q' ,near 0,, tart �' ` (Please referto product warranty for details) I. r_ ;' te, 1 CAUTION:READ SAFETY AND INSTALLATION INSTRUCFIONS BEFORE USING THE PRODUCT. I ¢'" Trim t€hoar°harrun y ,a<,;Jar J.'N..Wai/i 1y /''�'''{� O 2017 Trina Solar Limited.All rights reserved.Specifications Included in this datasheet are subject to change without notice. rinaso1y - ,,, Trina olar Version number:TSM_EN_2017_A www.trinasolar.com isiiiii