Loading...
Permit (99) CITY OF TIGARD MASTER PERMIT ` ' ! . '' COMMUNITY DEVELOPMENT Permit#: MST2017-00365 Date Issued: 10/09/2017 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DC11900 Jurisdiction: Tigard Site address: 17286 SW JEAN LOUISE RD Subdivision: POLYGON AT WEST RIVER TERRACE Lot: 119 Project: ALVARADO Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $10,270.28 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea adds 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Roof Top PV system. Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF 0 Owner: Contractor: ALVARADO,KATHERINE L&ROBERT GBLUE RAVEN SOLAR LLC Required Items and Reports(Conditions) 17286 SW JEAN LOUISE RD 1220 S 630 EAST,STE 430 SHERWOOD,OR 97140 AMERICAN FORK,UT 84003 PHONE: PHONE: 385-498-4408 FAX: Total Fees: $324.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable la . All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if w. m iss a for ore the 180 yv days. ATTENTION: Oregon law requires ou to follow the rules adopted by the Oregon Utility Notification Center f;,,'hose+^ru, are-''et • r in OAR 952-001-0010 through OA 952-001 090. Si may obtain copy of a rules or direct questions to OUNC by calling 503.23 or 1,,800 332'2 Issued By: •tre' 1 Permittee Signature: err Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY x CIt of Tigard -4 ft Received �5 // ] �' ./� p� Yg 3t .r t :$� Date/By: I /342 / Permit No.�1 L.STOV//-7' 042 Jt®� 111 e 13125 SW Hall Blvd.,Tigard,OR 97224.'''.' ' Plan Review �� Phone: 503.718.2439 Fax: 503.598.1960 Date/By: ) 0— 3 Other Permit: TIGARD Inspection Line: 503.639.4175 qy Date Ready/By: 1 ® See Page 2 for Internet: www.tigard-or.gov SEP fd Noti d/Method: w jq(t? J Supplemental Information ,3. <. ! TYPE , ' ;life. j lhern EiAT"A,I-.'-m..-: ,,...--°;-- ---7-,-iLLXN+ . ❑New construction btiii,c it#an'�`' a . ' > ' Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ElAddition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the \ ° to t ® ` , 1 �t\; work indicated on this application. �� .�-� r, =:r ���yvvwwvvva\w\how.v � ,, xs � ,�, .�� ��,a '.,-,AV I; $$10,270.28 01-and 2-family dwelling ❑Commercial/industrial ❑Accessory building ElMulti-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: Total number of floors: Job site address:17286 SW Jean Louise Rd New dwelling area: square feet City/State/ZIP:Sherwood, OR 97140 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Alvarado 4.85kw Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet v 1,IRED D' ' U RCIAL-VSE ,. is ,iia,,;,,>:,; . .- -�-� .: , Subdivision:CPO4b bull mtn Lot no.:R2196007 Permit fees*are based on the value of the work performed. } Tax map/parcel no.:2S106DC11900 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the ‘ vv 1 work indicated on this application. Rooftop solar PV 4.85kw Valuation: $ Existing building area: square feet New building area: square feet ` PROP r o<,- Vii't ,N4-;-*,O TENAN'x a �v� -,- =' Number of stories: Name:Robert Alvarado Type of construction: Address:17286 SW Jean Louise Rd Occupancy groups: City/State/ZIP:Sherwood, OR 97140 Existing: Phone:( )503-307-3723 Fax:( ) New: PPLICANT . ,,N,'� ' v CONTACT PERSON ,' BUILDING PERMIT FEES*v Business name: Blue Raven Solar (Pleaserefertofeeschedule) Structural plan review fee(or deposit): Contact name: Zach Schofield Address: 1220 S 630 E STE 430 FLS plan review fee(if applicable): City/State/ZIP: American Fork,UT 84003 Total fees due upon application: Phone:(385) 482-0045 Fax: :( ) Amount received: E-mail: permittin de blueravensolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES** g• Partment c� Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1220 S 630 E So/ar Installation Specialty Code checklist. City/State/ZIP: American Fork,UT,84003 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( ) Fax:( ) State surcharge(12%of permit fee): S2I.60 CCB lie.: #210112 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained �/ within 180 dad s after it has been accepted as complete. * Print name Jeffery Lee Date-09/26/2017 Fee methodology set by Tri-County Building Industry Sere ice Board. I: Building Permits BUP-RESPenwitApp.doc 02/24/2011 440-4613T(II/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY Received City of Tigard Cl k Date/By: Permit#: q 13125 SW Hall Blvd.,Tigard OR 91F23 s g 1 Plan Review lig 111 Phone: 503.718.2439 Fax: 503.59$.1960 Date/By: Related Permit#: Inspection Line: 503.63 9.4175 rra Ready eady D ate/Baay: Jris: I ® See Pagrie 2 forTIGAR } Internet: www.tigard-or.gov l:,1P2 8 ?0 17 Notified/Method: Supplemental Information ormation cl >tICie /WkYPU /w_ : ../=iint. a „ ; %% tite � \atkplo » ,, ws/ iti El New construction ❑■ Addition/alte”.t r /3e i °Eethei x in 0 Please check all that apply(submit 2 sets of plans w/items checked): ❑Demolition , � rl f a i > ❑wSehrevriecethoer afveaedilearbl4e0f0aualmt pcurrentore ❑❑Marinas g aonvderboatyards.i., AW-s.,.,.- d-0 � � eWoN � fr exceeds 10,000 amps at 150 volts or ❑Floating buildings. ■ 1-and 2-familydwellingless to ground,or exceeds 14,000 ❑Commercial-use agricultural ❑ ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. El Multi-family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or �� C"J (4 0J t; ! i& I ice/ iir Emergency system. larger separately derived ❑❑Addition of new motor load of system. Job#: Job site address:17286 SW Jean Louise Rd 100HP or more. ❑"A","E","1-2","1-3", ❑Six or more residential units. occupancy. City/State/ZIP:Sherwood, OR 97140 ❑Health-care facilities. ❑Recreational vehicle parks. ❑Hazardous locations. ❑Supply voltage for more than Suite/bldg./apt.#: Project name:Alvarado 4.85kw 600 volts nominal. ❑Service or feeder 600 amps or more. Cross street/directions to job site: 9 ��s l !IVO- Description Qty. I Each I Total * New residential single-or multi-family dwelling unit. Subdivision:CPO4b bull mtn Lot#: R2196007 Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#:2S106DC11900 , .' ! ' . ` %- 1 N„..%.. Limited energy,residenti0 sq.ft.or al 33.92 1 „ �,.T d� 75.00 2 Rooftop solar PV 4.85kw (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) m oRenew2 ✓moi ��,<.�.� �� �„� % ., V17, --y-';SIX-3,":3 �� Servicesable Ener or feeders installation,alteration,SeePa ande /or relocation Name:Robert Alvarado 200 amps or less 100.70 2 Address:17286 SW Jean Louise Rd 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Sherwood, OR 97140 601 amps to 1,000 amps 301.04 2 Phone:(503-)307-3723 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:rgalvarado58@gmail.com relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 W W Branch circuits-new,alteration,or extension,Per panel D AP's ICANTES€ 0\; . P A.Fee for branch circuits with Business name: Blue Raven Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: Brittany Gardner B.Fee for branch circuits without 1220 S 630 E STE 430 service or feeder fee,first Address: branch circuit 56.18 2 City/State/ZIP: American Fork,UT,84003 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(385 ) 482-0045 Fax: : ( ) Each manufactured or modular ermittin de artment r blueravensolar.com dwelling,service and/or feeder 67.84 2 Email: P g P Reconnect only 67.84 2 CONTRACTOR ', Pump or irrigation circle 67.84 2 Business name: Blue Raven Solar Sign or outline lighting 67.84 2 Address: 1220 S 630 E STE 430 Signal circuit(s)or limited-energy 0 See Page 2 2 panel,alteration,or extension. Each additional inspection over allowable in any of the above City/State/ZIP: American Fork, UT.84003 Additional inspection(I hr min) 66.25/hr Phone:( 385)482-0045 Fax: ( ) /te //, Investigation(I hr min) 90.00/hr Email: permitting.department a.blueravensolar.com � Industrial plant(I hr min) 78.18/hr Inspections for which no tee is 90.00/hr CCB Lic.: 210112 Electrical Lie.: C1214 Suprv.Lic.: 0976-° specifically listed(/z hr min) ELECTRICAL PERMIT FEES T Suprv. Electrician signature,required: Subtotal: I Print name: Sam Collier 00,_/;l‘_ Date: ❑Plan Review Required(250 of permit fee): State surcharge(12%,of permit fee): Authorized signature. TOTAL PERMIT FEE: "phis permit application expires if a permit is not obtained within 180 r �� Print name: Ben Wade Date:09/26/2017 dais after it has been accepted as complete. * Ntunho of inspections alloised per permit. I:'BuildinoPeroin H C_Pennit.App_-1 5 EREdoe Ree 06 1-?III° 4411-46 1511 1 1 11°(O1l lIIEB City of Tigard 'I Building Division 13125 SW Hall Blvd, Tigard, OR 97223 ¢ { 28 Phone: 503.718.2439 Fax: 503.598.1960 T I GARD Inspection Line: 503.639.4175 rF ` t www.tigard-or.gov 11 E r 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 17286 SW Jean Louise Rd City: Sherwood Zip: 97140 Owner's Name: Robert Alvarado Date: 09/26/2017 Contractor's Name: Blue Raven Solar CCB #: 210112 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? 0 No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure n Yes If"Yes", qualifies for "C" or less? No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ■ Yes the prescriptive path. and/or their accessory Ground structures. n No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than 10 Yes the prescriptive path. above No i Building,Forms/PhotoVoltaic-Chccklist.docx Is the construction material wood and does I] Yes Type of If"Yes", qualifies for the construction qualify Constructionas "conventional light n No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. n Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. n If"Yes", qualifies for Yes the prescriptive path. n No Is the combined weight n Yes of the PV modules and If"Yes", qualifies for racking less than or E No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation n Yes layout in accordance If"Yes", qualifies for with Section 305.4(3) of the 2010 Oregon Solar n No the prescriptive path. Code? Metal Single layer If roofing material is Roofing Check the type of n of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. • of composition shingle. Is the roof mounted • Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for No the prescriptive path. to the roof framing or blocking directly? 2 I:iBuilding Forms/PhotoVoltaic-Chccklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? n Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 'A"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ( I No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for III solar modules module to the roof Yes the prescriptive path. surface. I I No 3 l:/Building/Fonns/PhotoVoltaic-Checklist.docx a Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:Trina Solar Model Number:285 TSM-DDO5A.05(II) Listing Agency: CUS 4 I:/Building/Forms'PhotoVoltaic-Chccklist.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17286 SW JEAN LOUISE RD, SHERWOOD, OR, 97140 Record Type: Record ID: Residential - Master Permit MST2017-00365 Inspection Type: Inspector: 299 Final inspection Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 17286 SW JEAN LOUISE RD, SHERWOOD, OR, 97140 Record Type: Record ID: Residential - Master Permit MST2017-00365 Inspection Type: Inspector: 199 Electrical final Jeff Grove Result: PASS Comments: Violation Summary: Inspector Contractor