Loading...
Report (29) CT ENGINEERING INC / 180 Nickerson St. f o�b2 Suite 302 J 1,1 C54) ,(rj_W�prey h tL Seattle,WA 98109 � (206)285-4512(V) (206)285-0618(F) asolomon@ctengineering.com BULLETIN Date: August 28,2017 Number:CT-08 Project#: 16043 Project Name: River Terrace MF Attached: None Subject: Lots 171 & 174—Simpson Strong-Wall foundations Drawings Affected: Description/Action: • This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River Terrace MF' project located in Tigard, Oregon. Based on our review of the plans and the construction photographs provided by Polygon, it's our recommendation that the cracked concrete stem walls for the Simpson Strong-Walls be epoxy injected to provide proper concrete cover for the anchor rods. No fix/repair is required for the anchor rod connections to the concrete footing as, per the information we received from Polygon, it's our understanding that the anchor rods have proper embedment&concrete cover into the footings. I N4-0 �`y�,�`�•�REG i k��, ` 22, FF FS T. G 08/28/2017 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: Aug. 28, 2017 Distribution: Contact Information: Sam Scott Polygon Northwest Company Alexia Fukui Milbrandt Architects S:\16043 River Terrace(Areas 1 &2)\Bulletins\16043_2017.08.28_CT08_Lots 171 &174-Simpson Strong-Wall foundations.doc Structural Engineers