Loading...
Permit 1111 CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT COMMUNITY DEVELOPMENT Permit#: FPS2017-00147 Date Issued: 09/28/2017 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S101AD03200 Jurisdiction: Tigard Site address: 12909 SW 68TH PKWY 290 Project: Thenell Subdivision: WEST PORTLAND HEIGHTS Lot: 9-25,PT Project Description: Fire alarm notification devices for TI. Contractor: POINT MONITOR CORPORATION Owner: PACIFIC REALTY ASSOCIATES 5863 LAKEVIEW BLVD STE 100 ATTN: N PIVEN LAKE OSWEGO, OR 97035 15350 SE SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-627-0100 PHONE: FAX: 503-627-0110 FEES Description Date Amount Specifics: Permit Fee-COM 09/28/2017 $72.61 12%State Surcharge-Building 09/28/2017 $8.71 Type of Use: COM Plan Review-Fire Life Safety-COM 09/28/2017 $29.04 Class of Work: ALT Type of Const: IIB Info Process/Archiving-Sm$0.50(up to 09/28/2017 $2.50 Occupancy Grp: B Height: 40 ft 11x17) Stories: 4 Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: No Alarm Type: Automatic Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $112.86 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $1,229.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. IssuedBy: � Permittee Signature: 6V .0, Cy) 770 !!l�/// Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Et E 1 .h Fire Protection System SEP 2 7 2017 FOR OFFICE tS,1 ONL1 City of Tigard CITY OF TIGARD Received Date/13 : 9 cz"-er"/ _ Permit No S /7 00/y7 1111 3 13125 SW Hall Blvd.,Tigard,OR 972 Phone: 503.718.2439 Fax: 503.598. t ILDING I N G D I V3 S I O o; Other Permit: L,,2/7-aOZGI b T I t,A R D Inspection Line: 503.639.4175 Date Ready/By: Internet: www.tigard-or.gov Notified/Method 4� S See Page l2 fnr t� upp Informationementa Oji 1i_.. i2 jeic47— TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ®Commercial/industrial Valuation: $ ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builderNumber of bathrooms: \ 0 Other. 'Q JOB SITE INFORMATION AND LOCATION Total number of floors: 't tki Job site address:12909 SW 68th Pkwy. New dwelling area: square feet City/State/ZIP:Portland,OR 97223 Garage/carport area: square feet (.,1 Suite/bldg./apt.no.:290 Project name:Thenell Law Group Covered porch area: square feet U\ Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERGIAL.USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTTON OF WORK work indicated on this application. Fire alarm notification devices Valuation: $1,229 Existing building area: square feet New building area: square feet 0 PROPERTY OWNER. TE Number of stories: V Ve Name:Tinned Law Group Type of construction: Address:12909 SW 68th Parkway#290 /> Occupancy groups: !) City/State/ZIP:Portland,OR 97223 Existing. Phone:( ) Fax:( ) New: ID APPLICAN I 0 CONTACT PERSON NOTICE Business name:Point Monitor Corp. All contractors and subcontractors are required to be Contact name:Brooke Williams licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:5863 Lakeview Blvd#100 jurisdiction in which work is being performed.If the City/State/ZIP:Lake Oswego,OR 97035 applicant is exempt from licensing,the following reasons apply: Phone:(503)627-0100 Fax::( ) E-mail:bwilllams@pointmonitor.com CONTRACTOR BUILDING PERMIT FEES* Business name:Same as above (Pteasert(erroJtesebedate1 Permit fee: Address: City/State/ZIP: State surcharge(12%of permit fee): FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application submittal.) CCB lic.:135901 Total permit fees: Authorized signature �� Amount received: \_ --� __ .----- This permit application expires if a permit is not obtained Print name:Ben Breit Date:9/26/17 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I.Building Permits FPS-PamitApp_031016.doc 440-46137{11 O2COM-V.'EB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: ❑ New system Number of sprinkler heads: Number of alarm devices: ® Addition or 0 1-10 heads: Affidavit required and ® 1-5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3)copies of sketch showing area to existing of work within building structure of work within building structure system 0 11+heads: Plan review required and 0 6+devices: Plan review required and (3)sets of plans. (3) sets of plans. Additional description of work: Type of System(Complete A,B,C or D as applicable): b � A.) Commercial Sprinkler Sprinkler Type ❑ Wet 0 Dry Additional Standpipes Information: Sprinkler Supply Line ❑ Yes 0 No Hazard Group Density Design Area K.Factor Sprinkler Project Valuation: 1 $ B.) Type I Hood*Fire ttP $obiSlyAteM Hood Project Valuation: I $ C.) Fire Alarm Submittal shall Battery Calculations ® Yes include: Individual Component 1.1 Yes Cut Sheets Fire Alarm Project Valuation: I $ D.) Residential Sprinkler(Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq.ft. Fire Protection Permit Fees Project valuation subtotal(see A,B&C above): $ Permit fee based on project valuation(see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ (::\Users\bwilliams\llcsktop\I'I;R\11T 1'ORMS\fire permit-city of tigard.doc 2 RECEIVED City of Tigard SEP 2 7 2017 permit No.: 7-ea/ 7 111 al 13125 SW Hall Blvd, Tigard,OR : SI Phone 5017/8 2439 Fax 503 598 196401 I Y ik..,-iARF) Date Received: I Inspection Line. 503 639.4175 BtJILDIN(7: f',11.1iSk."1 5\ ACe0t4-- RI) Internet www.tigard-or go' FIRE ALARM SYSTEM AFFIDAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (MAXIMUM OF 5 DEVICES WITHOUT PLANS) Project Name: Thenell Law Group Occupancy: Same Job Address: 112909 SW 38th Pkwy#290, Portland, OR 97223 Suite: 290 Contractor: Point Monitor Corp. Phone: 503-627-0100 Valuation of work: $ 1,229 Type of System: (check one) ORequired NNon-required (check one) NAutomatic ['Manual E]Both Total number of devices added or moved under this permit process is 5 total per tenant space. Number of Proposed Smoke/Heat Detectors: To be Added(1 5) /To be Relocated(.5) Number of Proposed Manual Alarm Stations: To be Added on /To be Relocated(max 5) Number of Proposed Notification Appliances: To be Added 0).5) 3 /To be Relocated(.5) 2 1, Ben Breit Oregon Construction Contractors Board No. 135901 certify the following is true and defines the scope of work for this project: a) All work complies with the current state-adopted NFPA-72 and the authority having jurisdiction. b) All notification appliances are located in accordance with the current state-adopted NFPA-72. c) Smoke/Heat detector spacing complies with current state-adopted NFPA-72 and the authority having jurisdiction. d) Exposed wiring will not be covered until inspected. e) Final approval shall be subject to on-site tests and inspections. f) Voltage drop is adequate to operate all appliances. g) Battery supplies are capable of supporting the system modifications. h) Compatibility of appliances and devices are in accordance with the FACP manufacturer's specifications. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • Electrical permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: &--77. Date: 9/26/17 Print Name: Ben Breit I lBuildingiFonns\rireAlarmAffidavit_071514 docx Page 1 of I