Report (33) p STREET TREE
TIGARD CERTIFICATION
I, ,Aic.€u ekt.,sis , owner/agent forr-Pouti tiztikEs / t oL. - ,
(PLEASE PRINT) (PERMIT HOLDER)
do hereby cert that the following location meets
City of Tigard land use and development standards
for street tree installation and is consistent
with the approved site plan.
a)56,2—
PERMIT NO.: c--C 20 - .Et-
Sl
SHE ADDRESS: 13 3 30 S JP E ACji PQU 14-4 (S12-2AC
SUBDIVISION:
Mo IdfsT f2.4cg LOT#:
SIGNATURE: DA1J: o q- IF - 17
(OWNER/AGENT)
RECEIVED & �
VERIFIED BY•
DAM:IJ: 9/ 1/ 17
1-1 TTY F TIGARD
Tree location verified per approved site plan.
I:\Building\Forms\StreetTreeCertificate 05/30/2012
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, LA US.C.tLPc ( Yt,t iE sS'EtJ. , am the general contractor or the owner-builder
at the following address:
Site Address: ' 3,3 3 U cow 1f„au.-t r-PutA.vA-A.. 12 2erce
City: t G. 1IS I Oct N
Permit#: c-d- Zolko - 00 41
Subdivision/Lot#:
b N \OE.ST 21 e2- T'X-9-/V-6
and/or
Map and Tax Lot#: 8c
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: ,�, / - Date: 09-15 I 1
- eral :
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: Jurisdiction:
MST2oito-00 I C� F
Site Address: 3330
�tFK,lrl Qt.u.rti7t�Z.RRC£
Subdivision/Lot#:
uo d-T�t k Ec r- 1L v Trtga.Ac E
and/or
Map and Tax Lot#: SS / S .
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code Ni 107.2)1
Si
gnature: �-�, Date: Ocf- is-- i 7
O er/ ' �' :�"'�."�; onzed Agent
Print Name: G 1
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
1:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT' FORM
tG 1 Lt r eArtYLLS7EaJc 4 , am the galeal contractor or the owner—builder
at he fbllowing address:
Site Address: 1333 T EAc.{r4 }PU L rv►
Cit'Pol-{N SlAtItto 00 IS
Permit#: IMST2..o!to- 0041-
- #- 1
Snbd4visionfLot# u.044-14he- r R I vital I (1-4 tCE
and/or „
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1
Ventilation I am notifying the building official that I have installed tbe hOisstvre Banni.er as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet.this code , . ..
teen
rkr7Thh ground surface of the under-flooris
with space covered with 6-mil black polyethylenesheeting ,
[2 oints lapped 12"at seams and
[Erg:tending up the foinadation walls 12".
She: , r _ Date: 0 -
"*-- T,,P-wiaL.. o'ice°-*-.e. ti
L' ereES- .doo 09/13/2016
ST" 1,Zc1(7 ._ 00 ae20
CT ENGINEERING
INC 180 Nickerson St.
Suite 302
Seattle,WA 98109
(206)285-4512(V)
(206)285-0618(F)
asolomon@ctengineering.com
BULLETIN
Date: September 18, 2017 Number: CT-34 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 15 (Plan 17B)—Braced Wall Panel Adjacent to Garage Door
Drawings Affected: Detail 19/S1.2
Description/Action:
This bulletin provides response to RFI, design clarifications and/or variation requests for the `River
Terrace SF' project located in Tigard, Oregon.
At the locations where the top plate has been overnailed to the underside of the garage door header,
contractor to add (3) Simpson A35 framing angles that attach to both the top plate and garage door
header.
PR
��GI4��
Ni
q d
4REGIAlik
22,1c'1cc<c'
09/18/2017
CALL WITH ANY QUESTIONS
Issued by: Arnold R. Solomon Date: Sept. 18, 2017
Distribution:
Contact Information:
Ken Wilde Polygon Northwest Company
Alexia Fukui Milbrandt Architects
R:\15238 River Terrace SF\Bulletins\15238_2017.09.18_CT34_Lot 15(Plan 17B)-Braced Wall Panel Adjacent to Garage Door.doc
Structural Engineers