Report (43) 415)07-- 0r, 1 0 17/s--- 6to w4/kecit- Northwest The Suppression, Inc , 4 kV IT ) Ft I- ' i irt ,4,-- ,„, EQUIPMENT SUBMITTAL SEP 14 2Iii7 M t:'.1' FOR Fowler Middle School Fire Alarm System Modification 10865 SW Walnut Tigard, OR 97223 8/8/2017 SYSTEM Modification to the existing Fire Alarm System CONTENTS Manufacture Data Sheets 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-6444289 www.nwfire.com CCB#088629 Licensed e Bonded • Insured i di, (7 Northwest west The Suppression, k EQUIPMENT LIST Model Number Description 1 CPU2-640 Addressable Fire Alarm Control Panel 2 LEM-320 Loop Expansion Module 3 SBB-B4 2-Tier Fire Alarm Cabinet 4 DR-B4 2-Tier Fire Alarm Cabinet Door 5 DP-DISP2 Top Row Dress Panel 6 DP-1B 2nd Row Front Panel 7 NFS-LBB Battery Cabinet 8 FSP-851 Addressable Photo Electric Smoke Detector 9 B210LP 6" Base 10 DNR Addressable Duct Detector Housing 11 FSP-851R Addressable Duct Smoke Detector 12 DST 1 Sampling Tube 13 FRM-1 Addressable Relay Module 14 HSR Multi-Candela Horn/Strobe, Wall Mount, Red 15 HSWC Multi-Candela, Horn/Strobe, Ceiling Mount, White 16 STR Multi-Candela, Strobe, Wall Mount, Red 17 STWC Multi-Candela, Ceiling Mount, White 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwbre.com CCB#088629 Licensed • Bonded • Insured DN-7111:G,A-13 . N ® NOTIFIER® Fire Alarm System Intelligent Addressable by Honeywell onKU Intelligent Fire m Control P anels General The NFS2-640 intelFire Alarm ControPanel is part of the ONYX®Series of Fire Alarm Controls from NOTIFIER. ` In stand-alone or network configurations, ONYX Series prod ucts meets virtually every application requirement. The NFG2'840's modular design makes system planning eas- ier. Thopane| can be configured with just a few dsvices for [ small building app|icadona, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. A host of othi available, multi- channel voice; firefighters PC-based graphic annunciators; fire integration networking; advanced detection products for challenging onvmnments, and many additional options. NOTE: Unless called out with a version-specific "E"at the end of the part number, "NFS2-640" refers to models NF$2.-640 and NFS2-640E; similarly "CPU2-640" refers to models CPU2-640 anourua-64oE • FIA-485 annunniatom, including custom graphics. ~ Printer interface(80-column and 40-column printers). Features ` History file with 800—event capacity in nonvolatile memory, • Certified for seismic applications when used with the appro- plus separate 200-event alarm-only file. priate seismic mounting kit. ° Alarm Verification selection per point,with tally. • Approved for Marine applications when used with listed ° Preslgnal/Positive Alarm Sequence(PAS). compatible equipment(see 0N'60g8). • Silence inhibit and Auto Silence timer options, • One, expandable to two, isolated intelligent Signaling Line ° March time/temporal/California two-stage coding/strobe Circuit(SLC)Style 4,6 or 7. synchronization. • Up to 159 detectors (any mix of ion, photn, thermal, or • Field-programmable on panel or on PC, with VeriFire Tools multi-sensor) and 159 modules (Addressable pull otationm, program check,compare,simulate normally open contact devices, two-wire smnko, notifica- tion, or relay) per SLC. 318 devices per loop/636 per FACP • Full OVVERTYkeypad. or netwrk node. • Battery charger supports 18-2O0AHbatteries. • Standard 80-character display, 640-character large display • Non-alarm points for lower priority functions. (NCA-2,or display-less(a node on a network). • Remote ACK/Signal Silence/System Reset/Drill via monitor • Network options: modules. —High-speed network for up to 200 nodes <NFG2'3039. ° Automatic time control functions,with holiday exceptiQns. NFG2'640. NFS-320(C). NFG^32O8YS, NCA-2, DVC, " Surface Mount Technology(SMT)electronics. ONYXVVorom, NFG-3030. NFS-640,and NCA). " Extensive,buiItin transient protection. —Standard network for up to 103 nodes (NFG2-3030. NpS2-640. NFB'320(C). NF8'320SYS. NCA-2, ° pnwerfu|Boolean logic equations. ONYXWorks,NCS, NFS-3030, NFS-640,NCA,AFP-200, • Support for SCS Series smoke control system in HVAC AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes mode. when DVC is used in network paging. NCA-2 AS PRIMARY DISPLAY " 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System • Backlit,84U-chweoto,display. Sensor,Wheelock,or Gentex strobe synchronization. ° Supports SCS Series smoke control system in FSCS mode • Bui�|nA|o,no.Tmub|o.Swuuh1�and Sup*r�spryrelays. when SCS is connected to the NCA-2 used as primary display. • VeriFire®Tools online or offline programming utility.Upload/ Download,save,otom.check,uompae.and simulate panel ~ GuPpo���V�digi/w|eu�in|nnp� databases. Upgrade panel firmware. • Printer and CRT EIA-232 ports. • Autoprogramming and Walk Test reports. • EIA-485 annunciator and terminal mode ports. , Multiple central station communication options: ° Alarm,Trouble,Supervisory, and Security relays, —Standard UDACT RASH8CAA/0INTELL6GENT FEATURES —Internet ' Poll up to 318 devices in less than two seconds, —in\ernat/GSM ° Activate up to 159 outputs in less than five seconds. • 80-character remote annunciators(up to 32). ~ Multicolor LEDs blink device address during Walk Test. y Fully digital, high-precision protocol (U.S. Patent • No moving parts to fail or filters to change. 5,539,389). Early • Manual sensitivity adjustment—nine levels. warning performance comparable to the best aspira- tion,systems at a fraction of the lifetime cost. • Pre-alarm ONYX intelligent sensing—nine levels. Day/Night automatic sensitivity adjustment. FAPT-851 ACCLIMATE PLUS •• Sensitivity windows: LOW-PROFILE INTELLIGENT MULTI-SENSOR —Ion—0.5 to 2.5%/foot obscuration. • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases —Photo—0.5 to 2.35%/foot obscuration. with heat. —Laser(VIEW®)—0.02 to 2.0%/foot obscuration, • Microprocessor-based technology; combination photo and —Acclimate Plusim—0.5 to 4.0%/foot obscuration. thermal technology. —IntelliQuadTM—1.0 to 4.0%/foot obscuration. • FlashScan or CLIP("classic")mode compatible. —IntelliQuadTM PLUS--1.0 to 4.0%/foot obscuration • Low-temperature warning signal at 40°F ± 5°F (4.44°C t • Drift compensation(U.S. Patent 5,764,142). 2.77°C). • Degraded mode—in the unlikely event that the CPU2-640 FSC-851 INTELLIQUAD microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC ADVANCED MULTI-CRITERIA DETECTOR circuits and alarm relay. Each of the four built-in panel • Detects all four major elements of a fire (smoke, heat, CO, circuits includes a Disable/Enable switch for this feature. and flame). • Multi-detector algorithm involves nearby detectors in alarm • Automatic drift compensation of smoke sensor and CO cell. decision(U.S. Patent 5,627,515).) • High nuisance-alarm immunity. • Automatic detector sensitivity testing(NFPA-72 compliant). • Six sensitivity levels. • Maintenance alert(two levels). FCO-851 INTELLIQUADTM PLUS • Self optimizing pre alarm. ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR FSL-751 (VERY INTELLIGENT EARLY WARNING) • Detects all four major elements of a fire. SMOKE DETECTION TECHNOLOGY • Separate signal for life-safety CO detection. • Revolutionary spot laser design. • Optional addressable sounder base for Temp-3 (fire) or • Advanced ONYX intelligent sensing algorithms differentiate Temp-4(CO)tone. between smoke and non-smoke signals (U.S. Patent • Automatic drift compensation of smoke sensor and CO cell. 5,831,524). • High nuisance-alarm immunity. • Addressable operation pinpoints the fire location. • Six sensitivity levels. 9 LC Intelligent Loop t Upto32 Remote DEVICES Displaysift ---- I il14," FSC-851 intent Quad'. I-APT--651 Acclimate Plus' FSL•751 FlashSean0 VIEwc NBG-12LX FMM-1 FRM-1 XP€i10 [..,___,j } .. FSP-851 FlashSoene photo ♦ VO Modules etc. l 4o SLC Intelligent Loop 2 IDC Relay Contact I. i FDU-80 I_ LCD2-80 LCD2-80r * - FSP-851 FSI-351 FST-851 DEVICES 11 '1'1iii1 u Pnoto Ion Thermal "` s r s s �-===31 EIA-485 NBC-12LX FMM-1 FCM-1 XPIl1-M XP5-C KDM▪ -R269 MI Ea 0 69 t airy IDC NAC OR I I EIA-4$5 2048 annunci,tor/control points � t. NCA-2 #_LSV MI I--I L _.1 OR S ,� !i} r g _ I , r with no display i� I C i �� E .TJ _._ IN i 999 I� I = ACM-BR ACM/AEM-24AT � � • LDM-32 t � Relay Control LED Annunciator Custom Graphics Optional 636 point UDACT Dual phone lo lines to ---------i► Central Station Sample I u System NFS2-640 EIA-232 L___ Options "C" cabinet size shown PRN Printer 7111°ok.wmf Page 2 of 8—DN-7111:G•08/09/2012 RELEASING FEATURES self-restoring,and can be used to activate special control func- • Ten independent hazards. tions. • Sophisticated cross-zone(three options). Self-Optimizing Pre-Alarm: Each detector may be set for • Delay timer and Discharge timers(adjustable). "Self-Optimizing"pre-alarm. In this special mode, the detector • Abort(four options). "learns" its normal environment, measuring the peak analog Low-pressure CO2 listed. readings over a long period of time, and setting the pre-alarm • level just above these normal peaks. VOICE AND TELEPHONE FEATURES Cooperating Multi-Detector Sensing: A patented feature of • Up to eight channels of digital audio, ONYX intelligent sensing is the ability of a smoke sensor to • 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX consider readings from nearby sensors in making alarm or pre-alarm decisions.Without statistical sacrifice in the ability to series and DS series; NCA-2 required as primary display). resist false alarms, it allows a sensor to increase its sensitivity • Solid-state digital message generation. to actual smoke by a factor of almost two to one. • Firefighter telephone option. • 30-to 120-watt high-efficiency amplifiers(AA Series). Field Programming Options • Backup tone generator and amplifier option. Autoprogram. This timesaving feature is a special software routine. The FACP "learns" what devices are physically con- HIGH-EFFICIENCY OFFLINE SWITCHING netted and automatically loads them in the program with 3.0 A POWER SUPPLY(6.0 A IN ALARM) default values for all parameters. Requiring less than one min- e 120 VAC(NFS2-640);240 VAC(NFS2-640E). ute to run, this routine allows the user to have almost immedi- ate• Displays battery current/voltage on panel(with display), fire protection in a new installation,even if only a portion of the detectors are installed. FlashScan, Exclusive Keypad Program Edit(with KDM-R2)The NFS2.640, like all NOTIFIER intelligent panels, has the exclusive feature of pro- World-Leading Detector Protocolgram creation and editing capability from the front panel key- At the heart of the NFS2-640 is a set of detection devices and pad, while continuing to provide fire protection. The device protocol---FlashScan(U.S. Patent 5,539,389). FlashS- architecture of the NFS2-640 software is such that each point can is an all-digital protocol that gives superior precision and entry carries its own program, including control-by-event links high noise immunity. to other points. This allows the program to be entered with In addition to providing quick identification of an active input independent per-point segments, while the NFS2-640 simulta- neousiy monitors other(already installed)points for alarm con- device, this new protocol can also activate many output devices in a fraction of the time required by competitive proto- ditions. cols.This high speed also allows the NFS2-640 to have the VeriFire®Tools is an offline programming and test utility that largest device per loop capacity in the industry--318 points can greatly reduce installation programming time, and --yet every input and output device is sampled in less than increase confidence in the site-specific software. It is Win- two seconds.The microprocessor-based FlashScan detectors lows®-based and provides technologically advanced capabili- have bicolor LEDs that can be coded to provide diagnostic ties to aid the installer. The installer may create the entire information,such as device address during Walk Test, program for the NFS2-640 in the comfort of the office, test it, store a backup file,then bring it to the site and download from ONYX Intelligent Sensing a laptop into the panel. Intelligent sensing is a set of software algorithms that provider the NFS2-640 with industry-leading smoke detection capabil- in Chassis and Placement of dCYipi7l t ity, These complex algorithms require many calculations on ahlne each reading of each detector, and are made possible by the The following guidelines outline the NFS2-640's flexible sys- high-speed microcomputer used by the NFS2-640. tem design. Drift Compensation and Smoothing: Drift compensation Rows:The first row of equipment in the cabinet mounts in the allows the detector to retain its original ability to detect actual chassis shipped with the CPU. Mount the second, third, or smoke, and resist false alarms, even as dirt accumulates. It fourth rows of equipment in a CHS-4 series chassis or,for Dig- reduces maintenance requirements by allowing the system to ital Voice Command products, in CA-1 or CA-2. (For DVC and automatically perform the periodic sensitivity measurements DAA2/DAX components see DVC Manual, for DS series corn- required by NFPA 72. Smoothing filters are also provided by ponents see DS-AMP Manual; for DVC-AO applications, see software to remove transient noise signals, such as those AA Series Installation Manual.Other options are available; caused by electrical interference. see your panel's installation manual. Maintenance Warnings: When the drift compensation per- Wiring: When designing the cabinet layout, consider separa- formed for a detector reaches a certain level,the performance tion of power-limited and non-power-limited wiring as dis- of the detector may be compromised, and special warnings cussed in the NFS2-640 Installation Manual. are given, There are three warning levels: (1) Low Chamber Positions: A chassis offers four basic side-by-side positions value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance for components; the number of modules that can be mounted Urgent,indicative of dust accumulation above the allowed limit. in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and Sensitivity Adjust: Nine sensitivity levels are provided for hardware items available for different combinations and config- alarm detection. These levels can be set manually, or can urations of components. change automatically between day and night. Nine levels of It is critical that all mounting holes of the NFS2-640 are pre-alarm sensitivity can also be selected, based on predeter- secured with a screw or standoff to ensure continuity of Earth mined levels of alarm. Pre-alarm operation can be latching or Ground. DN-7111:G•08/09/2012—Page 3 of 8 Layers:The CPU's chassis accepts four layers of equipment, directly to the CPU2-640/-640E. On network systems (two or 'including the control panel.The CPU2-640 fills three positions more networked fire panel nodes), one network display(either (left to right)in the first-installed layer(the back of the chassis); NCA-2 or NCS/ONYXWorks) is required for every system, On its integral power supply occupies the center two positions in network systems, the NCA-2 connects to (and requires) a the next two layers;the optional display occupies(the left)two standard Network Control Module or High-Speed Network positions at the front, flush with the door. Some equipment, Control Module. Mounts in a row of FACP node or in two such as the NCA-2, may be mounted in the dress panel annunciator positions. Mounting options include the DP- directly in front of the control panel. The NCA-2 can be used DISP2, ADP-4B, or in an annunciator box, such as the ABS- as a primary display for the NFS2-640 (use NCA/640-2-KIT) 2D. In CAB-4 top-row applications,a DP-DISP2 and two BMP- by directly connecting their network ports (required in Cana- 1 blank modules are required for mounting. Required for dian stand-alone applications); see NCA-2 data sheet for NFS2-640 applications employing the DVC-EM with DAL mounting options(DN-7047). devices. See DN-7047. Expansion: Installing an LEM-320 Loop Expander Module CP U2440:Central processing unit with integral 3.0 A(6.0 A in adds a second SLC loop to the control panel,The LEM-320 is alarm) power supply fpr en NFS2-84,0 system Includes CPU mounted onto the CPU2-640,occupying the middle-right, sec- factory-mounted on a chassis; one Signaling Line Circuit and(back)slot on the chassis. expandable to two, installation, programming and operating Networking: If networking two or more control panel, each manuals• Order one per system or as necessary (up to 103 unit requires a Network Control Module or High-Speed Net- netwr"rk a'''les)ail a neterork system,: work Control Module. (HS-NCM can support two nodes; see CPU2-640E:Same as CPU2-640 but requires 240 VAC, 1.5 A, "Networking Options" on page 4). These modules can be (3.0 A in alarm). installed in any option board position (see manual), and addi- NCA/640-2-KIT: Bracket installation kit required to mount tional option boards can be mounted in front of the network control modules. NCA-2 to the CPU2-640/-640E's standard chassis. DP-DISP2: Dress panel for top row in cabinet with CPU2-640/ $CDM-R2 Controls and Indicators 640E installed. ADP2-640: Dress panel for middle rows with CPU2-640/6405. Program Keypad; QWERTY type (keyboard layout, see figure). BMP-1:Blank module for unused module positions. 12 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; BP2-4: Battery plate, required. Supervisory; System Trouble; Signals Silenced; Points Dis- LEM-320: Loop Expander Module. Expands each NFS2-640 abled;Control Active;Abort; Pre-Discharge; Discharge, to two Signaling Line Circuits. See DN-6881. Keypad Switch Controls:Acknowledge/Scroll Display;Signal NETWORKING OPTIONS Silence; Drill;System Reset;Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED NCM-W, NCM-F: Standard Network Communications Mod- backlight. ules. Wire and multi mode fiber versions available. See DN- 6861. Product Line Information HHS-NCM-W/MF/SF/WMF/WSFIMFSF: High-speed network communications modules that can connect to two nodes.Wire, • "Configuration Guidelines"on page 4 single-mode fiber, multi-mode fiber, and media conversion • "Networking Options"on page 4 models are available. See ON-60454. • "Auxiliary Power Supplies and Batteries"on page 4 RPT-W, RPT-F, RPT-WF: Standard-network repeater board • "Audio Options"on page 5 with wire connection (RPT-W), fiber connection (RPT F), or • "Compatible Devices, EIA-232 Ports"on page 5 allowing a change in media type between wire and fiber(RPT • "Compatible Devices, EIA-485 Ports"on page 5 WF),Not used with high-Speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, + "Compatible Intelligent Devices"on page 6 • "Enclosures,Chassis, and Dress Plates"on page 6 and hardware. See ON-7048 for specific part num- bars.• "Other Options"on page 7 NFN-GW-EM,NFN-GW-EM-3:NFN Gateway,embedded. See CONFIGURATION GUIDELINES DN-60499. Stand-alone and network systems require a main display, On AUXILIARY POWER SUPPLIES AND SA7TERIES single-CPU systems (one CPU2-640/-6405), display options ACPS-610: 6.0 A or 10 A addressable charging power supply. are the KDM-R2 or the NCA-2. On network systems (two or See DN-60244. more networked fire panel nodes), at least one NCA-2, NCS, or ONYXWorks annunciation device is required. Other options APS2'6R:Auxiliary Power Supply.Provides up to 6.0 amperes listed as follows; of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of KDM-R2:80-character backlit LCD display with QWERTY pro- four positions on a CHS-4L or CHS-4 chassis, See ON-5952, gramming and control keypad. Order two BMP-1 blank mod- ules and DP-DISP2 mounting plate separately. Requires top FCPS-24S6/S8; Remote 6 A and 8 A power supplies with bat- row of a cabinet. Required for each stand-alone 80-character tery charger. See ON-6927. display system, The KDM-R2 may mount in network nodes to BAT Series: Batteries. NFS2-640 uses two 12 volt, 18 to 200 display"local"node information as long as at least one NCA-2 AH batteries. See DN-6933. or NCS/ONYXWorks network display is on the system to dis- play network information. NCA-2: Network Control Annunciator, 640 characters. On sin- gle CP4J2-640/-6405 systems, the optional NCA-2 can be used as the Primary Display for the panel and connects Page 4 of 8•--ON-7111:G•08/09/2012 AUDIO OPTIONS and automatic switchover to backup tone. Order the AA-100 NOTE: For mounting hardware, see "Enclosures, Chassis, and for 70.7 VRMS systems and 100 watts of power. See DN-3224. Dress Plates"on page 6 and peripheral data sheets. DAA Series Digital Audio Amplifiers: Legacy DAA Series DVC-EM: Digital Voice Command,digital audio processor with amplifiers are compatible with DVC systems running SR4.0. message storage for up to 32 minutes of standard quality (4 For specific information on DAA-50 series amplifiers, refer to minutes at high quality) digital audio. Capable of playing up to DN-7046. For information on DAA-7525 Series, refer to DN- eight simultaneous messages when used with Digital Audio 60257. Loop(DAL)devices. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for COMPATIBLE DEVICES, EIA-232 PORTS PRN-6:80-column printer. See DN 6956. use with DVC-EM. Includes the keypad/display. See DN 60726. VS4095/5: Printer,40-column,24V. Mounted in external back- DS-DB: Digital Series Distribution Board, provides bulk ampli- box. See DN-3260. fication capabilities to the DVC while retaining digital audio dis- DPI-232: Direct Panel Interface, specialized modem for tribuition capabilities. Can be configured with up to four DS- extending serial data links to remotely located FACPs and/or AMPs,supplying high-level risers spread throughout an instal- peripherals. See DN-6870. lotion. See DN-60565, DVC-KD: Keypad for local annunciation and controls; status COMPATIBLE DEVICES, EIA-485 PORTS LEDs and24 user programmable buttons. See DN-7046. ACM-24AT: ONYX Series ACS annunciator—up to 96 points DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS switch perof circuit.cuiton ,Actith ve/Alam LEDs can be programmed (blarm or Active LED, Trouble LED, y requires DS-XF7OV step-up transformer. Digital Series Ampli- p g ( l- 9� p powered-up switch ,election) by point to be red, green, or yel- fier,part of the DS-DB system. See DN-60663. low;the Trouble LED is always yellow. See DN-6862. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for AEM-24AT: Same LED and switch capabilities as ACM-24AT, DVC, DS-DB distribution board, and DAX and DAA2 Series expands the ACM-24AT to 48,72, or 96 points, See DN-6862. amplifiers. See DN-60633. ACA:ONYX to 96 points of DVC-AO: DVC Analog Output board provides four analog out- annunciation nwi h AlaermAorSActiven LEDr perpcircuit. Active/ put circuits for use with AA Series amplifiers. Four-channel Alarm LEDs can be programmed(by powered-up switch seise- operation supported. See DN-7045, tion)in groups of 24 to be red, green, or yellow. Expandable to DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- 96 points with one AEM-48A. See DN-6862. bly with power supply;includes chassis. See DN-60556. AEM-48A: Same LED capabilities as ACM-48A, expands the DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier ACM-48A to 96 points. See DN-6862. assembly with power supply;includes chassis.See DN-60556. ACM-8R: Remote Relay Module with eight Form-C contacts. DAA2-7525(E):75W,25 Vrms digital audio amplifier assembly Can be located up to 6,000 ft. (1828.8 m) from panel on four with power supply;includes chassis. See DN-60556. wires. See DN-3558. DAX-3525(E): 35W,25 Vrms Digital Audio Amplifier assembly LCD-80: ACS mode. 80-character, backlit LCD display. with power supply, includes chassis. See DN-60561. Mounts up to 6,000 ft. (1$2$.8 m) from panel. Up to 32 per DAX-3570(E):35W, 70.7 Vrms Digital Audio Amplifier assem- FACP See LCD-80180TH(DN-3198). bly with power supply, includes chassis. See DN-60561. FDU-80: Terminal mode. 80 character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per DAX-5025(E):50W, 25 Vrms Digital Audio Amplifier assembly FAC P. See DN-6820. with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- LCD2-80; Terminal mode. 80-character, backlit LCD display. bly with power supply,includes chassis. See DN-60561, Mounts to -6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. Seeee DN-605548. TELH-1: Firefighter's Telephone Handset for use with the LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- DVC-EM when mounted in the CA-2 chassis. See DN-7Q45. R32; remote custom graphic driver modules, See DN-0551. CMIC-1: Optional microphone and microphone well assembly SCS:Smoke control stations SCS-8, SCE-8,with lamp drivers used with the CA-1 chassis. SCS-8L, SCE-8L; eight (expandable to 16) circuits. See DN- RM-11RM-1SA: Remote microphone assemblies, mount on 4818. ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) TM-4: Transmitter Module. includes three reverse-polarity cir- stand-alone cabinets. See DN-6728. cuits and one municipal box circuit. Mounts in panel module FTM-1: Firephone Control Module connects a remote fire- position (single-address-style) or in CHS2-M2 position. See fighter telephone to a centralized telephone console. Reports DN-6860. status to panel. Wiring to jacks and handsets is supervised. UDACT: Universal Digital Alarm Communicator Transmitter, See DN 6989. 636 channel. See DN-4867. AA-30: Audio Amplifier, 30 watts. Switch-mode power. UDACT-2: Universal Digital Alarm Communicator Transmitter, Includes amplifier and audio input supervision, backup input, 636 channel. See ON-60686. and automatic switchover, power supply, cables. See DN- - 3224. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- AA-120/AA-100: Audio Amplifier provides up to 120 watts of controlled, field-programmable from IBMS-compatible PCs 25 VRMS audio power for the NFS-640.The amplifier contains (requires optional programming kit). Up to 256 programmable an integral chassis for mounting to a CAB-B4, -C4, or -D4 codes. Mounts in BB-UZC or other compatible chassis (pur- backbox (consumes one row). Switch-mode power. Includes chased separately). See DN-3404, audio input and amplified output supervision, backup input, DN-7111:G•08/09/2012—Page 5 of 8 COMPATIBLE INTELLIGENT DEVICES FCM-1: FlashScan NAC control module. See DN-6720.. BEAMHK: Heating kit for transmitter/receiver unit of FSB- FCM-1-REL: FlashScan releasing control module. See ON- 200(5)below. See DN-6985. 60390. BEAMHKR: Heating kit for use with the reflector of FSB- FRM-1: FlashScan relay module. See DN-6720.. 200(S)below. See DN 6985. FDRM-1: FlashScan dual monitor/dual relay module. See ON- BEAMLRK: Long-range accessory kit, FSB-200(S) below. 60709. See DN 6985. NBG-12LX:Manual pull station,addressable. See DN-6726.. BEAMMKR: Multi-mount kit, FSB-200(S) below. See DN- ISO-X: Isolator module. See DN-2243. See DN-2243. 6985. BEAMSMK: Surface mount kit, FSB 200(5) below. See DN- XP6-C: FlashScan six-circuit supervised control module. See 6985. DN 6924. FSB-200: Intelligent beam smoke detector. See DN-6985. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection FSB-200S: Intelligent beam smoke detector with integral sen- zone. See DN-6925. sitivity test. See DN 6985. XP6-R: FlashScan six-relay (Form-C) control module. See FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria ON-6926. Detector. See DN-60412. XP1O-M: FlashScan ten-input monitor module. See ON-6923. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. ENCLOSURES, CHASSIS,AND DRESS PLATES FSI-851: Low-profile FlashScan ionization detector, See ON- CAB-4 Series Enclosure: NFS2-640 mounts in a standard 6934. CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered seperately; requires BP2-4 FSP-851: Low-profile FlashScan photoelectric detector. See battery plate. A trim ring option is available for semi-flush ON-6935. mounting. See DN-6857. FSP-851T: FSP-851 plus dual electronic thermistors that add EQ Series Cabinets: EQ series cabinets will house amplifiers, 135°F (57°C) fixed-temperature thermal sensing. See DN- power supplies, battery chargers and control modules. EQ 6935. cabinets are available in three sizes, "B"through"D". See DN- FSP-851 R: FSP-851, remote-test capable. For use with 60229. . DNR(W). See DN-6935. CAB-BM Marine System: Protects equipment in shipboard FST-851: FlashScan thermal detector 135°F (57°C). See ON- and waterfront applications. For a full list of required and 6936. optional equipment,see DN-60688. FST-851R: FlashScan thermal detector 135°F (57°C) with CHS-4:Chassis for mounting up to four APS-6Rs. rate-of-rise. See DN-6936. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 FST-851H: FlashScan 190°F(88°C)high-temperature thermal amplifiers or one AMG-E and one AA-30. detector. See DN-6936. DP-113: Blank dress panel. Provides dead-front panel for FAPT 851: FlashScan Acclimate Plus low-profile multi-sensor unused tiers;covers DAA2-series or AA-series ampiifier. detector, See ON-6937. NFS-LBB: Battery Box (required for batteries larger than 26 FSG-751: FlashScan VIEW laser photo detector. See ON- AH). 6886. NFS-LBBR: Same as above but red. DNR: InnovairFlex low-flow non-relay duct-detector housing CHS-BH1: Battery chassis; holds two 12.0 AH batteries. (order FSP-851 R separately). Replaces FSD-751 PL/FSD- Mounts one the left side of DAA2 chassis.See DN-7046. 751 RPL. See DN-60429. CA-1:Chassis,occupies one tier of a CAB-4 Series enclosure. DNRW: Same as above with NEMA-4 rating, watertight. See The left side accommodates one DVC and a DVC-KD DN-60429. (optional); and the right side houses a CMIC-1 microphone B224RB:Low-profile relay base. See DN-60054. and its well (optional). See DN-7045. B224BI: Isolator base for low-profile detectors. See ON- CA-2:Chassis assembly,occupies two tiers of a CAB-4 Series 60054. enclosure, The left side accommodates one DVC mounted on a half-chassis and one NFS2-640 or NCA-2 mounted on a B210LP: Low-profile base. Standard U.S. style. Replaces half-chassis. The right side houses a microphone/handset B710LP. See DN-60054. well.The CA-2 assembly includes CMIC-1 microphone.ADDR B501: European-style,4" (10.16 cm)base. See DN-60054. Series doors with two-tier visibility are available for use with B2005: Intelligent programmable sounder base, capable of the CA-2 configuration: ADDR-B4, ADDR C4, ADDR D4 producing a variety of tone patterns including ANSI Temporal (below). 3.Compatible with sychronization protocol. See DN-60054. CFFT 1: Chassis to mount firefighters telephone and one ACS B200SR: Sounder base, Temporal 3 or Continuous tone. See annunciator in a CAB-4 row. Includes TELH-1 firefighters DN-60054. handset for the DVC, chassis, phone well and mounting hard- ware.Order DP-CFFT dress panel separately. FMM-1: FlashScan monitor module. See DN 6720., DP-CFFT: CFFT-1 dress panel. Requires BMP-1 if no ACS FDM-1: FlashScan dual monitor module. See DN-6720.. annunciator is installed. FZM-1:FlashScan two-wire detector monitor module. See ON- ADDR-B4*:Two-tier-sized door designed for use with the CA- 6720.. 2 chassis configuration, ADDR Series doors are similar to FMM-101: FlashScan miniature monitor module. See ON- CAB-4 Series "DR"doors, but a clear window space exposes 6720. Page 6 of 8-ON-7111:0•08/09/2012 Op top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-B4. See DN-7045, DN-6857. ADDR-C4*: Three-tier-sized door, designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045,DN-6857. ADDR-D4*: Four-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. *Use ADDR-B4/C4/D4 when CA-2 chassis is installed in top two rows with NCA-2 or BP-CA2.Use standard door when CA- 2 is not installed in top two rows. Please see the DVC applica- tion guide for additional configuration information. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC, DVC-KD,and CMIC-1. See DN-7045. DPA-2B: Dress panel used with CA-2 chassis assembly. VP-2B: Dress panel, required when CA-2 chassis is installed in the top two cabinet rows. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. BP-CA2: Blank plate for CA-2 chassis. BB-UZC: Backbox for housing the UZC-256 in applications where the UZC-256 will not fit in panel enclosure. Black; for red,order BB-UZC-R. SEISKIT CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-640 and other equipment mounted in CAB-4 Series Enclosures.Includes battery bracket for two batteries up to 26 AH. SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. SEISKIT-PS/2/4: Seismic mounting kit for the FCPS-24S6/S8 and CAB-PS1, Includes battery bracket for two 7 AH or 12 AH batteries. OTHER OPTIONS 411:Slave digital alarm communicator,See DN-6610. 411 UDAC: Digital alarm communicator.See DN-6746. IPDACT 2/2UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for internet communications over customer-provided ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT:V-adaptor option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input: IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket;Red. For Black order IPENC-B. IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- cator. Provides selectable configurable paths: cellular only, IP only,or IP primary with cellular backup.Connects to the primary and secondary ports of a DACT. Replaces IPGSM-CQM. See DH-60695. NOTE:For other options including compatibility with retrofit equip- ment,refer to the panel's installation manual,the SLC manual,and the Device Compatibility Document. DN-7111:G•08/09/2012—Page 7 of 8 , , SYSTEM SPECIFICATIONS System Capacity Agency Listings and Approvals • Intelligent Signaling Line Circuits 1 expandable to 2 The listings and approvals below apply to the basic NFS2-640 • Intelligent detectors 159 per loop control panel. In some cases, certain modules may not be • Addressable monitor/control modules 159 per loop listed by certain approval agencies, or listing may be in pro • Programmable software zones 99 cess.Consult factory for latest listing status. Special programming zones 14 • UL Listed:S635. • • ULC Listed: S635. • LCD annunciators per CPU2-640/-640E and NCA-2 (observe power) 32 • FM Approved. • ACS annunciators per • MEA; 128-07-E. CPU2-640/-640E 32 addresses x 64 points • FDNY:COA#6085. • ACS annunciators per • CSFM:7165-0028:0243. NCA-2 32 addresses x 64 or 96 points • city of Chicago. NOTE: The NCA-2 supports up to 96 annunciator address points . City and County of Denver. per ACM-24A17-48A. • CCCF listed. Specifications When used with the CAB-BM Marine System, appropriate seismic bracket, and marine approved devices, these ONYX • Primary input power: fire alarm control panels are approved by the following agen- -CPU2-640 board: 120 VAC,50/60 Hz,5.0 A. cies: —CPU2-640E board:220/240 VAC,50/60 Hz,2.5 A. • US Coast Guard: 161.002/50/0(Standard 46 CFR). • Total output 24 V power:6.0 A in alarm. • Lloyd's Register: 11/600013(ENV 3 category). NOTE: The power supply has a total of 6.0 A. of available power. • American Bureau of Shipping. This is shared by all internal circuits. NOTE: For information on the CAB-BM marine system, see • Standard notification circuits(4): 1.5 A each. DN-60688. • Resettable regulated 24V power: 1.25 A. • Two non-resettable regulated 24V power outputs: Standards —1.25 A. The NFS2-640 complies with the following UL Standards and —0.50 A. NFPA 72, IBC,and CBC Fire Alarm Systems requirements: • Non-resettable 5V power: 0.15 A. • UL 864,9th Edition(Fire). • Battery charger range: 18 AH—200 AH. Use separate cabi- • UL 1076(Burglary). net for batteries over 26 AH. • LOCAL (Automatic, Manual, Waterflow and Sprinkler • Float rate:27.6 V. Supervisory). • AUXILIARY (Automatic, Manual and Waterflow) (requires Cabinet Specifications TM-4). Systems can be installed in CAB-4 Series cabinets (four sizes • REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory)(requires TM-4). with various door options,see DN-6857). Requires BP2-4 Bat - •Plate. • PROPRIETARY(Automatic, Manual and Waterflow). Not applicable for FM. Shipping Weight • EMERGENCY VOICE/ALARM. • CPU2 640/640: 14.3 lb(6.49 kg). • OT, PSDN (Other Technologies, Packet-switched Data Net- work). • CPU2-640/-640E: 14.55 lb(6.60 kg). • IBC 2000,IBC 2003,IBC 2006,IBC2009(Seismic). Temperature and Humidity Ranges • CBC 2007(Seismic). This system meets NFPA requirements for operation at 0-- 49°C/32—120°F and at a relative humidity 93%±2%RH NOTI•FIRE•NETTM, IntelliQuadTM, and ONYXWorksTM are (noncondensing)at 32°C±2°C(90°F±3°F). However,the trademarks; and Acclimate® PIusTM, FiashScan®, NOTIFIER®, useful life of the system's standby batteries and the electronic ONYX®,VeriFire®,and VIEW®are registered trademarks of Honeywell components may be adversely affected by extreme International Inc.INicrpsoft®and Win�ows®are registered trademarks tempera- ture ranges and humidity. Therefore,it is recommended that Corporation. f Micr000ft Corporation. IBM® is a registered trademark of ISM C this system and its peripherals be installed in an environment ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use with a normal room temperature of 15–27°C/60–80°F of this document is strictly prohibited. 9001I This document is not intended to be used ffor installation accurate.0 purposes. We tryto keepour product information up-to-date ate. We cannot cover all specific applications or anticipate all requirements. 98I EBIM I AWIMCORMS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 8 of 8—DN-7111:G•08/09/2012 DN-6881:Al •A-35 LCM-320 and LEM-320 8 Loop Control and Expander Modules N (�T F R by Honeywell Intelligent Fire Alarm Control Panels General The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER's ONYX®Series of Fire '' ' Alarm Control Panels (FAPs) with Signaling Line Circuits ' (SLCs).The ONYX®Series NF8440/NFS rf 40 supports ones LEM-320; the NES-3030/NFrS2-3030 supports up to five j " LCM-320s and five LEM-3206, The LEM-320 module is `t used to expand the NFS-640/NFS2-640 to a second p, expandga t-..,� loo and to each LCM-320 used on the NFS-3030/ �� f NFS2-3030—each NFS-3030/NFS2-3030 LCM-320 supports �' 0.;an expansion LEM-320. .. ' Features ' �LL'."�� • Up to 12,500 feet(3,810 m)on a Class B(Style 4)SLC loop ANB l,a n, z ` � (twisted-unshielded). gal • Built-in degraded mode increases survivability. • Very simple installation—plug-in style. : f- � • Permits multiple loops in small enclosure, ; f •ai` • , ' Specifications Loop Control Loop Expander Voltage:24 VDC nominal,27.6 VDC maximum. Module Module Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2)twisted-pair wire is 12,500 feet Product Line Information (3810 rn) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2)to 18 AWG (0.78 mm2): LCM-320: Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- -Distance with 12 AWG: 12,500 ft(3,810 m). 320s and five LEM-320s. -Distance with 14 AWG:8,000 ft(2,438 m). LEi -32o: Loop Expander Module. Expands each LCM used -Distance with 16 AWG:4,875 ft(1,486 m), on the NFS-3030/NFS2-3030;expands NFS-640/NFS2-640 to -Distance with 18 AWG:3,225 ft(983 m). tWO;loops -50 ohms maximum per length of Style 6&7 loops. -50 ohms maximum per branch for Style 4 loop, Agency Listings and Approvals Maximum current:for LCM-320: 130 mA;for LEM-320: 100 The listings and approvals below apply to the basic LCM-320 mA;for single SLC loop:400 mA maximum, and LEM-320. In some cases, certain modules may not be NOTE;Maximum short circuit,-.loop will shut down until short-cir listed by certain approval agencies, or listing may be in pro- cuit condition is corrected. cess.Consult factory for latest listing status. Maximum resistance: 50 ohms (supervised and power- • UL:8635 limited). • ULC: S635/CS118 Temperature and humidity ranges: This system meets • FM Approved NFPA requirements for operation at 0-49°C/32- 120°F and • CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 at a relative humidity 93%t 2% RH (noncondensing) at 32°C with NFS-3030/NFS2-3030). 7165-0028:214, 7170- 2°C (90°F t 3°F). However, the useful life of the system's 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- standby batteries and the electronic components may be 0028:244(LEM-320 with NFS2-640). adversely affected by extreme temperature ranges and humid- . PONY:COA#6025(LEM-320 with NFS2-640) ity. Therefore, it is recommended that this system and its • peripherals be installed in an environment with a normal room FDNY:COA#6026(LCM-320/LEM-320 with NFS2-3030) temperature of 15-27°C/60-T 80°F. • City of Denver • Hong Kong • DN-6881.A1 a 06/05/2009—Page 1 of 2 FLASHSCAN, and NOTIFIER® are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Is 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BIiIIIERIN I MINIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6881:A1 •06/05/2009 DN-6857:A•G-190 AB- , :series abinets 8 NOTIFIER ONY Series Backboxel with Looking Doors by Honeywell Peripheral Devices General All cabinets for NOTIFIER fire alarm control panels are fabri- cated from 16-gauge steel. The cabinet assembly consists of two basic parts: a backbox and a locking door. Cabinets are available in either black or red, with or without LEXAN® win- r dows. The LEXAN model provides a tasteful combination to accent the decor of the finest lobby setting. I • The key-locked door is provided with a pin-type hinge, two keys and the necessary hardware to mount the door to the backbox. • The backbox has been engineered to provide ease-of-entry for the installer. Knockouts are positioned at numerous points to aid the installer in bringing a conduit into the enclo- sure with a minimum of hardship. """`• • Right- or left-hand hinges, selectable in the field. Door opens 180°. • Cabinets are arranged in four standard sizes, A (one tier) through D(four tiers),plus a mini cabinet(AA, one tier with- out a battery compartment).See Ordering Information. "°"""p • A trim ring option is available for semi-flush mounting. • Chassis bridge available for assembling multiple CHS-4 chassis external to the backbox. NFS-640 in "B"sized CAB-4 cabinet Ordering Information TR-A4: Accessory semi-flush-mount trim ring,one tier(opening A complete cabinet assembly consists of:a door,a backbox,an 24.062"[61.118 cm]W x 20.062"[50.958 cm]H), BLACK. optional battery plate, and an optional semi-flush trim ring. For NOTE:Black trim rings are used with red or black cabinets. each cabinet required, order one "DR" door and one "SBB" backbox. The BP-4 or BP2-4 battery plate is required for each BP-4: Battery panel for NFS-640 and NFS-3030. Used to cabinet assembly that mounts batteries and/or a power supply cover battery and power supply when lower position is used in in the lower position of the cabinet. The optional trim ring is an backbox. attractive"picture frame'-style black metal ring. BP2-4: Battery panel for NFS2-3030.Used to cover battery and MINI"AA"SIZE, ONE TIER: power supply when lower position is used in backbox. TWO DR-AA4: Door assembly, LEXAN window, one tier(no battery TIER "8"SIZE: compartment),BLACK. DR-B4: Door assembly,LEXAN window,two tiers, BLACK. DR-AA4R: Door assembly,LEXAN window,one tier(no battery DR-B4R: Door assembly,LEXAN window,two tiers,RED. compartment), RED. DR-B48: Door assembly,solid door,two tiers, BLACK. DR-AA4B: Door assembly,solid door,one tier(no battery corn- DR-B4BR: Door assembly,solid door,two tiers, RED. partment),BLACK. $SB-B4; Backbox aseembly,two tiers,BLACK. DR-AA4BR: Door assembly, solid door, one tier (no battery SBB-84R: Backbox assembly,two tiers,RED, compartment),RED. TR-84: Accessory semi-flush-mount trim ring, two tiers (open- SBB-AA4: Backbox assembly, one tier (no battery comport- ing 24.062"[61.118 cm]W x 28.562"[72.548 cm]H), BLACK. ment), BLACK. NOTE:Black trim rings are used with red or black cabinets. SBB-AA4R: Backbox assembly, one tier (no battery compart- ment), RED, BP-4: Battery panel for NFS-640 and NFS-3030. Used to TR-AA4: Accessory semi-flush-mount trim ring, one tier (no cover battery and power supply when lower position is used in battery compartment). backbox. NOTE:Black trim rings are used with red or black cabinets. BP2-4: Battery panel for NFS2-3030.Used to cover battery and power supply when lower position is used in backbox. ONE TIER, "A"SIZE: THREE TIERS, "C"SIZE: DR-A4: Door assembly,LEXAN window,one tier, BLACK. DR-C4: Door assembly, LEXAN window,three tiers, BLACK. DR-A4R: Door assembly, LEXAN window,one tier, RED. DR-C4R: Door assembly,LEXAN window,three tiers, RED. DR-A4B: Door assembly,solid door,one tier,BLACK. DR-C48: Door assembly,solid door,three tiers,BLACK. DR-A4BR: Door assembly,solid door,one tier, RED. DR-C4BR: Door assembly,solid door,three tiers,RED. SBB-A4: Backbox assembly,one tier,BLACK, SBB-C4: Backbox assembly,three tiers,BLACK, SBB-A4R: Backbox assembly,one tier,RED. SBB-C4R: Backbox assembly,three tiers,RED. DN-6857:A•11/30/06—Page 1 of 4 TR-C4: Accessory semi-flush-mount trim ring, three tiers (open- BP2-4: Battery panel for NFS2-3030.Used to cover battery and ling 24.062"[61.118 cm]W x 37.187"[94.455 cm]H),BLACK. power supply when lower position is used in backbox. NOTE:Black trim rings are used with red or black cabinets, ACCESSORIES: BP-4: Battery panel for NFS-640 and NFS-3030. Used to WC-2: Wire channel. Provides a pair of wire trays to neatly cover battery and power supply when lower position is used in route wiring between CHS chassis. backbox. BP2-4: Battery panel for NFS2-3030.Used to cover battery and CB-1: Chassis bridge. Provides a bridge between CHS Series Chassis. power supply when lower position is used in backbox. DP-13: Blank dress panel,covers one CAB-4 tier,BLACK. FOUR TIERS, "D"SIZE: ADP-4B: Annunciator dress panel. DR-D4: Door assembly, LEXAN window,four tiers, BLACK. DR-D4R; Door assembly, LEXAN window,four tiers, RED. Agency Listings and Approvals DR-D4B: Door assembly,solid door,four tiers,BLACK. These listings and approvals below apply to the CAB-4 Series DR-D4BR: Door assembly,solid door,four tiers,RED. Cabinets. In some cases, certain modules or applications may SBB-D4: Backbox assembly,four tiers,BLACK. not be listed by certain approval agencies, or listing may be in process.Consult factory for latest listing status. SBB-D4R: Backbox assembly,four tiers, RED. • UL Listed:file S635(except AA size). TR-D4: Accessory semi-flush-mount trim ring, four tiers (open- • ULC Listed:file CS118 (except AA size). ing 24.062"[61.118 cm]W x 45.812"[116.363 cm]H),BLACK. • Note:Black trim rings are used with red or black cabinets. MEA approved:files 317-01-E,345-02-E (except AA size). BP-4: Battery pane! for NFS-640 and NFS-3030. Used to • CSFM approved(except AA size):files 7165-0028:214(NFS- cover battery and power supply when lower position is used in 030 3 7170-0028:216 (NFS-640), 7165-0028:224 (NFS- backbox. 3030),7170-0028:223(NFS-3030). • FM approved(except AA size). • U.S.Coast Guard approved: 161.002/42/1 (NFS-640). : £ naA.� ,1 . °„ .. . ., ,' ter.: Cabinet Dimensions and Features (13.097) (8.187) j 5.156" 2,d4' CAB4keyho!e.wmf _ •- _r_-- 1 5.93. Knockouts on 1 (15.082) 1.i25 1 , top of cabinets. ` - (2.85®Cm) 1 ' (0.83 I (0.895 Cm) i 7.12' Height of --- -- i i-1- / (18.084) mounting bolt 0.500 1 , -- -t i _ - t - - after installation (1.27 cm) b / KNOCKOUTS: / 5,83' Inner: / 0.875"(2.223) (15.062) Keyhole ice-- Outer: dimensions 0.500 ) 1.125"(2.858) a -- '' (1.27 Cm) `• Vg Top knockout: Inner 1.375'(3,49) Outer 1.750"(4.45) *--- 24"(60.96) --f i +-- 24.125"(61.28) a iq.16); 5.218" 2.063" Ir-4^. ( ) 'V (13254)! (5-24) ► ---96" 40.64 v \ r.-----v. t _ - 1 r _ ,. ! i 1.625" . ! II "A" SIZE� (I I I ! (4.13) 8625" CABINETi , . (21.9^) 20.125" ! 11.281" (51 12) i L 0.313"dia. j i I ._. - , (28.053) (079) 20" I .1, (50.80)• . ' Iw. - 19.5"(49.53) - --► 11 (� ) 1 \ . __ . _ _„i i � ! cab-a4.2003wrnf 2 2.25"(5 72) -- -.. e.a 1_ 6.51 1 (6.51) Lower knockout:I Inner 0.875"(2.22) Outer 1-125"(2.86) Page 2 of 4-DN-6857:A•11/30/06 I Top knockout Inner 1 375"(3.49) Outer 1,750"(4.45) +_.__........_..... 24"(60.96) _........_.. 5.218" 2A6.. 3.... " - 24.125"(61.28) -_--; (13.254) (5.24)► 4"-+w-- 16 (40.64) -r; (4.13) 193 " -#7/- I � 8 \ }1625" 1 "AA" E 4 62°(1 1.74) (35.624) 0.313"da (35.31) _.0 � A ET ' (2794] r...- 1 \ • / :...... . ....._ /cm( 1 .. cab-b4-2003.wm` r l ....._ ...... 4-- 19.5"(49.53) r14-4 -n 4-- 2.56" (6.51) 2.25"(5.722)/ Lower knockout: Inner 0,875"(2.22) Outer 1..125"(286) Top knockout; Inner 1.375"(3.49) Outer 1.750"(4.45) •4----------24"60.96) 5.218" 2.063" 4---- 24.125"(61.28) --a (1016); 1.625" 4 ►N 16"(40.64) (13.254) (5.24) (4 13) jII C Ij-. "B" SIZE .) 6 25" 1 (291 )CABINET 19.781" - (50 24) 28.625" III 28,5" 18.625" (72.71) I 0.313"dia. II I (21.91) ( (0.79) . (72.39) ' �'-' ,J+ I I V----- 19.5"(49.53) --r4--1-•2.25" 11 (5.72) . (cm) �� • , 1 � 4 ! • ) cab-b4-2003.wmf 2.56 ` 2.25"(5.72) "---r.: -a; 4-- (6.51) j Two lower knockouts ' Inner 0.875"(2.22) Outer 1.125"(2.86) Top knockout: Inner 1.375"(3.49) Outer 1.750"(4,45) *---------24"(60.96) >r .__ 10 16 1.625" r 5.218" 063' 24 125'(61 28) w t k * 4 ►r 16 (40.64) + (4.13) (13.254)1 (5.24) 4,- - � I y"C" SIZ I 1 8.625, CABINET ! 11 (21.91) til 1:.,.,' 11 28.094" 8.625" (71.36) 1 (21.91) ail 1 1 tlfi,_-I.. �'--.- 1 I 8.625" 37.25" ' Ilj ( ' I 37.125" I (21.91) (94.62) I I (94.3) f 0.313"dia. (0.79) 1 r z.... k * 19.5"(49.53) _ .r+ 12.25" 1(5.72) . 2.25" i___ ) \ • (5.72) 11 (cm) 1 �i 1 cab-c4-2003.wmf T• J 2 56" j (6.51)l Three lower knockouts r Inner 0.875"(2.22) Outer 1.125"(2.86) DN-6857:A•11/30/06-Page 3 of 4 - r Top knockout. Inner 1.375"(3.49) Outer 1.750"(4.45) �— —24"(60.96) e 24.125"(61.28) .,i (10,16); 1.625" ( 5.218" 2.063" .-4 *14-----16"(40.64) --Di i (4.13) ,, 13.254 (5.24) 1 (a i�—�- "D" SIZE �_ I I �ir CABINET j I I (21.91) 8.625' (21.91) 37.031" w 11 (94.05) 8.625" (21.91) l 8.625" 45,875" (11852) I (116.21) II (21.91) 1 0.313"dia. I r (0.791 t vI I {3�- I I k 4- 19.5"(49.53) ►;e —2.25" I 1 \ 1 (5.72) • 2.25" I (5.72) (cm) sr cab-d4-2003.wmf 2.56" i -# 4— (6.51) Four Iowa,knockouts ' Inner 0.875'(222) ------- ----2;•-:-..=........- ---- -._:; . . Outer 1.126"(2.66) Li I n o n n. I 6857bp4.wmf The BP-4 Battery Dress Panel covers the Main Power Supply and the batteries in the cabinet. "D"sized cabinet Only one BP-4 or BP2-4 is required per 1 with solid door.. cabinet unless an AA cabinet is used(no p. Solid door option available battery compartment). g on all sizes in black or red. ONYX®and NOTIFIER©are registered trademarks of Honeywell Interna- tional Inc.LEXAN®is a registered trademark of GE Plastics,a subsidiary of General Electric Company. ©2006 by Honeywell International Inc.Ali rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO aa, We try to keep our product information up-to-date and accurate. C R T E cr We cannot cover all specific applications or anticipate all requirements, INCL iEMINB 6 PENNIMAN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6857:A•11/30/06 DN-6857:B•0-190 CAB-4 Series Cabinets N OT I F I E Re ONYX® Series Backboxes with Locking Doors by Honeywell Peripheral Devices General All cabinets for NOTIFIER fire alarm control panels are fabri- cated from 16-gauge steel. The cabinet assembly consists of two basic parts: a backbox and a locking door. Cabinets are available in either black or red, with or without windows. The a 1 window model provides a tasteful combination to accent the decor of the finest lobby setting. • The key-locked door is provided with a pin-type hinge, two keys and the necessary hardware to mount the door to the backbox. • The backbox has been engineered to provide ease-of-entry for the installer. Knockouts are positioned at numerous points to aid the installer in bringing a conduit into the enclo- sure with a minimum of hardship. • Right- or left-hand hinges, selectable in the field. Door opens 180°. • Cabinets are arranged in four standard sizes, A (one tier) through D(four tiers),plus a mini cabinet(AA, one tier with- out a battery compartment).See Ordering Information. • A trim ring option is available for semi-flush mounting. * Chassis bridge available for assembling multiple CHS-4 chassis external to the backbox. NFS2-3030 and DVC in"C"sized CAB-4 cabinet Ordering Information TR-A4: Accessory semi-flush-mount trim ring,one tier(opening A complete cabinet assembly consists of: a door, a backbox,an 24.062"[61.118 cm]W x 20.062"[50.958 cm]H),BLACK. optional battery plate, and an optional semi-flush trim ring. For NOTE:Black trim rings are used with red or black cabinets. each cabinet required, order one "DR" door and one "SBB" backbox. The BP-4 or BP2-4 battery plate is required for each BP-4: Battery panel for NFS-640 and NFS-3030. Used to cabinet assembly that mounts batteries and/or a power supply in cover battery and power supply when lower position is used in the lower position of the cabinet, The optional trim ring is an backbox. attractive"picture frame"-style black metal ring. 8P2-4: Battery panel for NFS2-3030.Used to cover battery and MINI"AA"SIZE, ONE TIER: power supply when lower position is used in backbox. DR-AA4: Door assembly,window,one tier(no battery comport- nvo?YEAST", "a„sizE: ment), BLACK. OR-04: Door assembly,window,two titre,BLACK DR-AA4R: Door assembly, window, one tier (no battery corn- DR-B4R: Door assembly,window,two tiers,RED. partment), RED. DR-84B: Door assembly,solid door,two tiers,BLACK. DR-AA4B: Door assembly,solid door,one tier(no battery corn- DR-B4BR: Door assembly,solid door,two tiers, RED, partment),BLACK. SBB-34: Backbox assembly,two tiers, BLACK. DR-AA4BR: Door assembly, solid door, one tier (no battery SBB-B4R: Backbox assembly,two tiers, RED. compartment), RED, y, SBB-AA4: Backbox assembly, one tier (no battery compact- TR-B4:: Accessory semi-flush-mount trim ring, two tiers (open, ment), BLACK ing 24.062"[61.118 cm]W x 28.562"[72.548 cm]H),BLACK. SBB-AA4R: Backbox assembly, one tier (no battery compart- NOTE;Black trim rings are used with red or black cabinets, ment), RED. BP-4: Battery panel for NFS-640 and NFS-3030. Used to TR-AA4: Accessory semi-flush-mount trim ring, one tier (no cover battery and power supply when lower position is used in battery compartment). backbox, NOTE:Black trim rings are used with red or black cabinets. BP2.4: Battery panel for NFS2-3030.Used to cover battery and power supply when lower position is used in backbox. ONE TIER, `A"SIZE: THREE TIERS, "C"SIZE: DR-A4: Door assembly,window,one tier,BLACK. DR-C4: Door assembly,window,three tiers,BLACK. DR-A4R: Door assembly,window,one tier, RED. DR-C4R: Door assembly,window,three tiers, RED. DR-A4B: Door assembly,solid door,one tier, BLACK. DR-C48: Door assembly,solid door,three tiers,BLACK. DR-A4BR: Door assembly,solid door,one tier, RED, DR-C4BR: Door assembly,solid door,three tiers, RED, SBB-A4: Backbox assembly,one tier,BLACK. SBB-C4: Backbox assembly,three tiers, BLACK. SBB-A4R: Backbox assembly,one tier,RED. SBB-C4R: Backbox assembly,three tiers, RED. DN-8857:B•8/11/2010—Page 1 of 4 I TR-C4: Accessory semi-flush-mount trim ring, three tiers (open- ACCESSORIES: ii g 24.062"[61.118 cm]W x 37.187"[94.455 cm]H),BLACK. WC-2: Wire channel. Provides a pair of wire trays to neatly NOTE:Black trim rings are used with red or black cabinets. route wiring between CHS chassis, BP-4: Battery panel for NFS-640 and NFS-3030. Used to CB-1: Chassis bridge. Provides a bridge between CHS Series cover battery and power supply when lower position is used in chassis. backbox. DP-1B: Blank dress panel,covers one CAB-4 tier,BLACK. BP2-4: Battery panel for NFS2-3030.Used to cover battery and ADP-4B: Annunciator dress panel. power supply when lower position is used in backbox. VP-2B: Ventilator panel. FOUR TIERS, "D"SIZE: DR-D4: Door assembly,window,four tiers,BLACK. Agency Listings and Approvals DR-D4R: Door assembly,window,four tiers, RED. These listings and approvals below apply to the CAB-4 Series DR-D4B: Door assembly,solid door,four tiers,BLACK. Cabinets. In some cases, certain modules or applications may DR-D4BR: Door assembly,solid door,four tiers, RED, not be listed by certain approval agencies, or listing may be in process,Consult factory for latest listing status. SBB-D4: Backbox assembly,four tiers,BLACK. • UL Listed:file S635(exceptAA size). SBB-D4R: Backbox assembly,four tiers, RED. • ULC Listed:file CS118(except AA size). TR-D4: Accessory semi-flush-mount trim ring,four tiers(open- • MEA approved:files 317-01-E,345-02-E(except AA size). ing 24.062"[61.118 cm]W x 45.812"[116.363 cm]H),BLACK. • CSFM approved (except AA size): files 7165-0028:0243 Note:Black trim rings are used with red or black cabinets. (NFS2-640),7165-0028:0224(NFS2-3030). BP-4: Battery panel for NFS-640 and NFS-3030. Used to • FM approved(exceptAA size). cover battery and power supply when lower position is used in . U.S.Coast Guard approved: 161.002/42/1 (NFS-640). backbox. • FDNY COA#6038, COA#6058. BP2-4: Battery panel for NFS2-3030.Used to cover battery and power supply when lower position is used in backbox. msµ, .. e '-. : ,-0.--.. ,'.. . '' .. ��... a 'Rets,. -; c ^"4.,t, Cabinet Dimensions andFeatures (13.097) (6.197) 5.156" ' 2.44 ----4;/_ CAB4keyhole.wmf _ 15.93" 1 Knockouts on (15.062) 1.126 ( top of cabinets. {* (2.858 cm) 4-a 0.250 (0.635 cm) 7.12° Height of --Pr -____---�___r / (18.084) mounting bolt 0.500 t ) ti after installation (1'27 nm) _f KNOCKOUTS: I �' J I Inner 5.93' 0.875"(2.223) (15.062) Keyhole ► 1 Outer: E dimensions0.500 1 1.125"(2.858) --��i--- - '�---- (1.27 cm) I Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) + —24"(60.9x) •. 1 5-5(32° 2-1/16" 4—-- 24-1/8"(61.28) (9.16); s-q"-►r- 16"(40.64) ,: �� (131) (824) # --r ___ _ 11', ,',j, t 1 q --I I,/ �rc�f� SIZE1-5;s" I (4.13) 1 1 8 518" CABINET '1 20-1;8 11=9132" 2L9i} 51 12) 5/16"dia. 5/16"dia. (. (28.06) 2Q.. (9.79) (0.79) 1 11.0_,14_____i-- (50.80) f*----19-1/2"(49,53) ► I i 1 (cm) �� I... N cab-a4-2003.wmt 2-9/16" 2-1/4"(5.72) -a. i .1., ,4..-" (F.51) Lower knockout:, Inner 0.875'(2.86) Outer 1.125'(2.22) Page 2 of 4---DN-6857:B•8/11/2010 Top knockout: Inner 1.375"(3.49) - r ' Outer 1.750"(4.45) , 4. 24"(60.96) -4. 5.218" 2.063" 24.125"(81.28) ' (10,161 --", ',42.44.4-- 16"(40.64) -4,,.i 1 N. (13.254)F (5.24) .3.:384 0 .., t - :` (11.74). /• 1 , 14.025" "AA" SIZE (35.624) . 0.313"dia. 10.79) (27.94) (. 5. ;) 4.62" I CABINET (cm) .1, cab-b4-2003.wmf 4-- 19.5"(49.53) ------44-:--4. -•.; 41-- 2.56" 2 (6.51) '• 2.25"(5.72)/ Lower knockout: Inner 0.875"(2.22) Outer 1.125"(2.86) Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) , A--------------24"(60.96) r• I 5-5/32" 2:1/16" 1---- 24-1/8"(61.28) ..., (10.16): 1-5/8" 16"(40.64) --------H (4.13) , (131) (524) f T . I '7-------,7--- i 1 t? 1. - - "B" SIZE ; ,...,-... . , , 1 . 8-5/8" 11 , , (21.91) CABINET 1 ! !i 19-25/32" _. 1 I I 11 1 . 8-5/8" (72.71) : j ' ,',I / i 1 5/16"dia. 5/16"dia- II 1 (7239) (21.91) '---4---. 1 \ 4----19-1/2"(49.53) ----40 i 2-1/4" I / (5.72) . • ' I i . H (cm) ' 1 tr L.., . cab-b4-2003.wmt 2-9/16" / 2-1/4 (5.72) -4-6-, --fiff 4---, (65.088)/ Two lower knockouts i Inner 0.875"(2.88) Outer 1.125"(2.22) Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.451 4---------------24"(50.96) ------0'1 I 5-5/32" 2-1/16" 24-1/8'(61.28) I ..: (10.16): / 1-5/8" -: 16"(40,64) ------4 i (4.13) L...,, (13.1) ; (52.4) ill i 14- `/ '+''' --1---4-1 -,-"T-,--f I "C" SIZE 1 ! ! . \•:--..i., 8-5/8" 11 CABINET . I (21.9)) ! ' . , r i : • . !_____••___._________ 1 1 ---- I , i 1 , 1 111.11 , , 28- /32" -- ; t77 8-5/8" . 37-1/8"F (21.91) (94.62) I (94,3)5/16"dia. 5/16"dia. . 1 ---v . . 1 , (0.75) (079) . \ - - - - , H ,OL? I \ 1k,4 19-1/T(49.53) 44------2-1/4" I r : 1 \ ' . (5.72) 1 i 1 \ 1 1 2-1/4" I i (cm)(5.72) . : 1 _5C .I__- 2-9/16"1 cab-c4-2003,wmt ---,4 4-- (6.51)/ Three lower knockouts/ Inner 0.875"(286) Outer 1.125"(222> DN-6857:B•8/11/2010-Page 3 of 4 s 1 Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) r 24"(60.93) •, 1 5-5/32" 2-1/16" ( ) (19.16): 1-5/8" 24-1/8 91.28 a^ 4.,**---.16 (40.64) --, ; (4.13) (1 1) ! ( �T — �� 3 5 24) ® SIZE i T,_ " " ' I li 8-5/8' CABINET I ' (21.91) — j 8-5/8" (21.91) ' 37-1/32" f w ! (94.06) 8.5/8" (21.91)1 -�— —1-- 45 7/8" 45-3/4" 8.5/8" (11 .52) --- (116.21) (2191) iso 5/t6'dia. 5/16"did, (0.79) (0.79) (_ ''-‘-‘,?t,-- 1 ��' 19 1/2"(49.53) — va ! 2.1/4" ��'� ' (5.72) 2-1/4" (5.72) (CM) l- cab-d4-2003.wmf— r T - 2-9/16 _i.; 4........ {6.51) I / Four lower knockouts Inner 0.875"(2.8E) a-_—_ _ _. _._.,C Outer 1.125"(2.22) 7' n°8i8 ..,.:.........""Pin. n..& °...< 6857bp4.wmt The BP-4 Battery Dress Panel covers the Main Power Supply and the batteries in the cabinet. "D"sized cabinet Only one BP-4 or BP2-4 is required per with solid door. cabinet unless an AA cabinet is used(no Solid door option available battery compartment). § on all sizes in black or red. ONYX®and NOTIFIER®are registered trademarks of Honeywell Interna- tional Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. � ® ®�' We try to keep our product information up-to-date and accurate. c s a T r F r E[> We cannot cover all specific applications or anticipate all requirements. 81MNELMNI IMANIFACiIMIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—ON-6857:B•8/11/2010 - • , , NFS-LBB Battery Cabinet Battery/Peripherals Enclosure Product Installation Document PN 50295:B 07/24/2001 ECN 01-250 This cabinet consists of a backbox with an integral, lockable door that is hinged on the bottom to swing ----- -r down for access. �J ��,_ r- `' It is designed to be mounted a minimum of 6 inches ...--<--- \„_-_----- " "�NJP �. (15,24 cm)below the fire alanu control panel FACP 1 (FACP). When both cabinets are surface mounted, I the knockout in the bottom-right corner of the FACP 1 will line up directly above the knockout in the top- 8 inch right corner of this enclosure. minimum Conduit (15.24 cm) This enclosure should be mounted in a clean,dry, _ _ __ vibration-free area,using the six holes provided. 0 Note:The enclosure has 0.875 in.(2.2225 cm) Battery/Peripherals Enclosure knockouts which accept standard 0,75 in.(1.905 cm) conduit. C____._1 2.801 mm) i I I I 2.66 in. t (87.564 min) 7.730 in. Top . _._. (196.342 mm) --24.125 in.(612.775 mm) --- Left Side Door 3.875 In. 7.730 in. (88'425 mm) 16.00 in.(406.4 mm) I (196.342 mm) 1.___8.00 In. '1 1 !(203.2 mm) 1 i 4.00 in. mg i I , 1 1 2.125 in. (101.6 mm) Ellin 0 .. .... .._._.�,..... . ....._.._(53.975 mm) 1 1 � I I I . 1 • I I 14.06 in. I I (357.124 mm) I I 15.00 In, 1 I 10.00 M. . I (381 mm) I 1 . {254 mm) 1 F. . I 1 14.751n I I (374.85 m O 7.250 in. 1.25 in 23.750 in.(803.25 mm)-----_— (1x4.15 mm) (31.75 mm) Front (without door) 1 Battery/Peripherals Enclosure PN 50295:B 07/24/2001 DN-6935:D•H-202 Fsp.881(A) series NOTIFIER Intelligent Plug.ln Photoelectric Smoke Detectors with FlashScan , by Honeywell Intelligent/Addressable Devices General Notifier FSP-851(A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con ventional detectors. Detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851(A) photoelectric detector's unique optical sensing Ake chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add a • 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851T(A).The FSP-851 R(A)is a remote test capable detector for , use with DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP FSP-$51(A) in B210LP(A) Base series Fire Alarm Control Panels(FACPs). FlashScan®(U.S. Patent 5,539,389)is a communication proto- _B200SR(A):6.875"(17.46 cm)diameter. col developed by Notifier that greatly increases the speed of B224RB(A):6.2"(15.748 cm)diameter. communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion.If one of the devices —B224BI(A):6.2"(15.748 cm)diameter. in the group has new information, the panel's CPU stops the Shipping Weight:5.2oz. (147g). group poll and concentrates on single points. The net effect is Operating Temperature range: FSP-851(A), 0°C to 49°C response speed greater than five times that of earlier designs. (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +/- 10°F Features (7.22°C+/-5.54°C).FSP-851 R(A)installed in a DNR(A)/DNRW, • Sleek,low-profile design. -20°C to 70°C(-4°F to 158°F). • Addressable analog communication. ULt1ILC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ • Stable communication technique with noise immunity. min.),suitable for installation in ducts. Low• standby current. Relative Humidity: 10%-93%noncondensing. • Two-wire SLC connection. Thermal Ratings:Fixed-temperature setpoint 135°F(57°C). • Compatible with FlashScane and CLIP protocol systems. DETECTOR SPACING AND APPLICATIONS • Rotary,decimal addressing(1-99 on CLIP systems, 1-159 on Notifier recommends spacing detectors in compliance with FlashScan systems). NFPA 72. In low airflow applications with smooth ceiling, space • Optional remote,single-gang LED accessory. detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) • Dual LED design provides 360°viewing angle. and higher. For specific information regarding detector spacing, • Visible bi-color LEDs blink green every time the detector is placement, and special applications refer to NFPA 72. System addressed, and illuminate steady red on alarm (FlashScan Smoke Detector Application Guide, document A05-1003, is systems only). available at systemsensor.com • Remote test feature from the panel. ELECTRICAL SPECIFICATIONS • Walk test with address display (an address on 121 will blink Voltage Range: 15-32 volts DC peak. the detector LED: 12-[pause]-1(FlashScan systems only). Built-in functional test switch y external Standby Current(max. avg.): 300pA @ 24VDC (one commu- • activated bxtlmagnet. nication every five seconds with LED enabled). • Built-in tamper-resistant feature. LED Current(max.):6.5mA @ 24 VDC("ON"). • Sealed against back pressure. • Constructed of off-white fire-resistant plastic, designed to InStaftation commercial standards,and offers an attractive appearance. • 94-5V plastic flammability rating. FSP-851(A) plug-in detectors use a separate base to simplify SEMS screws for wiring of the separate base. installation, service, and maintenance, A special tool allows • maintenance personnel to plug in and remove detectors without • Optional relay,isolator,and sounder bases. using a ladder. Mount base(all base types)on an electrical backbox which is at Specifications least 1.5" (3.81 cm) deep. For a chart of compatible junction Sensitivity:0.5%to 2.35%per foot obscuration boxes,see DN-60054. Size:2.1"(5.3 cm)high;base determines diameter. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "7:taps" or B210LP(A):6.1"(15.5 cm)diameter. branches are permitted for Style 4 (Class B) wiring. 2) When —B501(A):4.1"(10.4 cm)diameter. using relay or sounder bases, consult the ISO-X(A) installation —B200S(A):6.875"(17.46 cm)diameter. DN-6935:D•12/08/2011--Page 1 of 2 sheet 156-1380 for device limitations between isolator modules ACCESSORIES and isolator bases. F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low- Agency Listings and Approvals profile. These listings and approvals apply to the modules specified in F110BP:Bulk pack of F110; package contains 15. this document, In some cases, certain modules or applications F210: Replacement flange for B210LP(A)base. may not be listed by certain approval agencies,or listing may be RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to a in process. Consult factory for latest listing status. U.S. single-gang electrical box. For use with B501(A) and • UL Listed:S1115. B210LP(A)bases only. • ULC Listed:S1115(FSP-851A, FSP-851RA,FSP-851TA). SMB600: Surface mounting kit • MEA Listed:225-02-E. M02-04-00:Test magnet, • FM Approved, M02.09-00:Test magnet with telescoping handle. • CSFM:7272-0028:0206. • Maryland State Fire Marshal: Permit#2122. XR2B: Detector removal tool.Allows installation and/or removal BSMI 01313066760036. of detector heads from bases in high ceiling applications. • CCCF Certif.#2004081801000017(FSP 851 T) XP-4:Extension pole for XR2B.Comes in three 5-foot(1.524 m) Certif.#2004081801000016(FSP-851). sections. • U.S. Coast Guard: 161,002/42/1 (NFS-640); 161.002/50/0 T55-127-010:Detector removal tool without pole. (NFS2-640/NFS-320/NFS-3200,excluding B210LP(A)). BCK-200B:Black detector covers for use with FSP-851(A)only; • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- box of 10. 320C,excluding B210LP(A)). WCK-200B: White detector covers for use with FSP-851(A) only;box of 10. Product Line Information NOTE:"A"suffix indicates ULC Listed model. FSP-851; Low-profile intelligent photoelectric sensors Must be mounted to one of the bases fisted below FSP-851A:Same as FSP-851 but with ULC listing, FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C)fixed-temperature thermal device. FSP-851TA:Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE:A"suffix indicates ULC Listed model. NOTE:For details on intelligent bases,see DN-60054. B210LP(A) Standard U.S.flanged low-profile mounting base, 8210LPBP:Bulk pack of B214LP;package contains 10. B501(A):Standard European flangeless mounting base. B501BP:Bulk pack of B501;package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. 8200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces 8501 BH series bases in retrofit applications. 82248B(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A i 30 VDC resistive;0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. -Notifier® and FlashScan® are registered trademarks of Honeywell B224B1(A): Plug-in System Sensor isolator detector base. International Inc. Maximum 25 devices between isolator bases. ©2011 by Honeywell International Inc.AU rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. EAT r F i116-ACID We cannot cover all specific applications or anticipate all requirements. MCINNIS&MANAFMcIIIINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S,A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6935:D•12/08/2011 DN-60054:l•H-320 NIt n e"1 1+ n uses Standard, Relay Isolator, Sounds NOTI8 ER® - and Low-Frequency Sounder Bases by Honeywell Intelligent/Addressable Devices General , Intelligent FlashScan® and CLIP mounting bases and kits provide a variety of ways to install NOTIFIER detectors in any ��, a application. Intelligent detectors can be mounted in either a t flanged or flangeless bases depending on junction box selec Y" g tion (see Junction Box Selection Guide). Across this product " s line, detectors plug in easily to the base with SEMS screws; Flangeless Mounting Base Flanged Mounting Base and models employ various 12 to 24 AWG wire ranges. B501(A) B21OLP(A) Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C � contact relay for control of auxiliary functions such as door , a closure and elevator recall. Isolator bases allow loops to con- tinue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are avail- -�, '; able in temporal and non-temporal pattern versions depend s s, ing on whether the signal is to be used for evacuation purposes. Low frequency sounder bases are UL listed for low Sounder Base Relay Base frequency operation and comply with NFPA 72 requirements 82005(A),B200SR(A), 8224RB(A) for sleeping spaces. B200SCOA This datasheet discusses the following bases: 8501(A), B200S(A), B200S-LF, B200SR(A), B200SR-LF, 8210LP(A), 8224181(A), B224RB(A), B200SCOA, mounting kits, and accessories. ., Specifications Diameter: Low-Frequency Sounder Base i 13200S-LF,B200SR-LF °° • 8501:4.1"(104 mm). • 8224E31, B224RB, 8210LP:6,1"(155 mm). Electrical Ratings • 6.87 5, 7.46 c ). B200SR, 820058-LF B200SCOA: FOR €32005, 8200S-LF, B200SR, 8200SR-LF, 6.875" (17.46 cm}. Wire gauge: 82005COA: • 622481, 822488: 14 to 24 AWG. External supply voltage: 16 to 33 VDC(VFWR) • 821 OLP, 8501, 8200S, B200S-LF, 8200SR, 8200SR-L!, Standby current: B200SCOA: 12 to 24 AWG • 13200S: 500 pA maximum. Temperature range: • 8200S-LF,550 pA maximum, • 8224BI, B224RB, B200S, B200S-LF, B200SR, B200SR- • B200SR:500 pA maximum. LF, B200SCOA:32°F to 120°F(0°C to 49°C). • B200SR-LF: 1 mA maximum. • 821 OLP, 8501:-4°F to 150°F(-20°C to 66°C), Alarm current: Humidity range: 10%to 93%RH, non-condensing, • 82005:35 mA maximum at high-volume setting; System temperature and humidity ranges: This system 15 mA maximum at low-volume setting. meets NFPA requirements for operation at 0°C to 49°C(32°F • 82005-LF, High-volume setting: to 120°F); and at a relative humidity(noncondensing)of 85% at 30°C (86°F) per NFPA, and 93% t 2% at 32°C ± 2°C '-70 mA maximum @ 33.0 VDC. (89.6°F t 1.1°F)per ULC. However,the useful life of the sys- -°90 mA maximum © 24.0 VDC. tern's standby batteries and the electronic components may --140 mA maximum @16.0 VDC. be adversely affected by extreme temperature ranges and . B200S_LF, Low-volume setting: humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal —15 mA maximum C 33.0 VDC. room temperature of 15°C to 27°C(60°F to 80°F). —20 mA maximum ca 24.0 VDC. —25 mA maximum a 16.0 VDC. • 8200SR:35 mA maximum. • B200SR-LF: —65 mA maximum @ 33.0 VDC. DN-60054:1.2/3/2015—Page 1 of 4 —90 mA maximum © 24.0 VDC, B224RB: Relay base. ' ' —125 mA maximum CO 16.0 VDC. B224RBA: Relay base, ULC Listed. • B200SCOA:40mA Max. (DC), 70mA Max. (FWR) SLC operating voltage: 15 to 32 VDC. 622461; Isolator base. SLC standby current: See applicable sensor specification. 6224BIA: Isolator base, ULC Listed. Sound output: MOUNTING KITS AND ACCESSORIES • B200S/B200S-LF, high-volume*: Greater than 85 dBA SMB600: Surface mounting kit,flanged. minimum. F110: Retrofit flange for converting high-profile bases to low- • B200S/B200S-LF,low-volume*:Greater than 75 dBA mini profile. mum. F110BP: Bulk pack of F110(10). • B200SR*/B200SR-LF*: Greater than 85 dBA minimum. F210: Accessory flange ring for B210LP(A) base (new • B200SCOA, high-volume**: Greater than 87 dBA mini- design).6 in diameter, mum. F210BP: Bulk pack of F210(10). • B200SCOA, low-volume**:Greater than 85 dBA minimum *Measured in a UL reverberant room at 10 feet,24 Volts(continuous tone) RA100Z: Remote LED annunciator. "Measured in a ULC anechoic room at 10 feet,24 Volts continuous tone) RA100ZA: Remote LED annunciator, ULC Listed. FOR B224RB,B224BI: M02.04-00: Detector test magnet. Operating voltage: 15 to 32 VDC(powered by SLC). M02-09-00:Test magnet with telescoping handle. Standby ratings:<500 IA maximum (c3 24 VDC. XR2B: Detector removal tool for current heads (T55-127-010 Set time (B224RB only): short delay 55 to 90 msec; long included). delay 6 to 9 seconds. XR2: Detector Remove Tool for use with low profile detector Reset time(B224RB only):20 msec maximum. heads,and FSL-751. XP-4 Extension pole for XR2/13 (5 to 15 ft/1.524 to 4.572 m), Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A oe 125 T55-127-010: Detector removal head. VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC. BCK-200B: Black detector kit, package of 10 (for use with Product Line Information photo and ion detectors). INTELLIGENT BASES WCK-200B:-White detector kit, package of 10 (for use with photo and ion detectors). 8501: Flangeless mounting base. 13501A: Flangeless mounting base, ULC Listed. Agency Listings and Approvals 8501 BP:Bulk pack of 13501 (10). The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may 0210LP: Flanged mounting base, not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. B210LPA:Flanged mounting base, ULC listed B210LPBP:Bulk pack of 13210LP(10). • UL Listed: 5911, 51115. B200S: Intelligent addressable sounder base capable of pro • ULC Listed: S911, S1115. ducing sound output in high or low volume with ANSI Tempo- • FM Approved. ral 3,ANSI Temporal 4,continuous tone, marching tone, and • MEA:22-95-E,205-94-E Vol.2;257-06-E custom tone. Uses FlashScan protocol. Only compatible with • CSFM: 7300-1653:0126, 7135-1653:0213, 7300- the NFS-320, NFS2-640 and NFS2-3030 operating version 1653:0109 with version 15.0 or higher panel firmware. B200SA: ULC-listed version of 8200S. B200SCOA: ULC-listed version of B200S with CO detector markings in English/French (required in Canada for ULC applications with FCO-851A). B200S-LF: Low Frequency version of the 82005;produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleep- ing space requirement. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: ULC-listed version of B200SR. B200SR-LF: Low Frequency version of the B200SR; pro- duces a fundamental frequency of 520 Hz +1. 10% with a square wave or its equivalent;designed to meet the NFPA 72 sleeping space requirement. Page 2 of 4 s DN-60054:1.2/3/2015 " 'Junction Box Selection Guide Sinle 1 4.0"Sq. - Base Models Gang 3.5"Oct. 4.0"Oct. 4.0"Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S,B200S-LF, B200SR,B200SR-LF, Yes Yes Yes Yes Yes No No No No B200SCOA I B501 No Yes No No Yes Yes Yes Yes No 4 B210LPYes Yes Yes Yes Yes No No No No — B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes 'Yes Yes No No No Yes Yes NOTE:Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. DN-60054:!•2/3/2015—Page 3 of 4 FlashScant),NOTIFIERI and System SensorO are registered trademarks of Honeywell International Inc. 02015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. !SO 9 I 01 We try t0 keep our product information up-to-date and accurate. CFrs: We cannot cover all specific applications or anticipate all requirements. t31IDINIIIINE A MANINA IAlMB All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www,notifier.com Page 4 of 4—DN-60054:1•2/3/2015 DN-60429:C1 DNR(A)/DNRw irbriov irFl E x Intelligent N©n 44elay Photoelectric (i3) NOTIFIER Duct smoke Detector by Honeywell General . _ Intelligent Devices G The Notifier InnovairFlex®DNR(A)intelligent non-relay photo v � � � �,� �� - •� � � � electric duct smoke detector and DNRW watertight non-relay • photoelectric duct smoke detector feature a pivoting housing - •that fits both square and rectangular footprints capable of � �� • 4 • mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection e- ,m against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute(0.5 ; •to 20.32 m/s), temperatures of-4°F to 158°F (-20°C to 70°C), _' and a humidity range of 0 to 95 percent(non-condensing.) An improved cover design isolates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) cates a trouble signal for a removed or improperly installed Width,2.5 in (6.6 cm)Depth. sensor cover. The Notifier InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- Size:(Square)7.75 in(19.7 cm)Length;9 in(22.9 cm)Width; ing and mounting of a relay module. 2.5 in(6.35 cm)Depth. The Notifier InnovairFlex duct smoke detector can be custom- Weight: 1.6 lb(0.73 kg). ized to meet local codes and specifications without additional Operating Temperature Range: -4°F to 158°F (-20°C to wiring.The new InnovairFlex product line is compatible with all 70°C). previous Innovair models, including remote test accessories. Storage Temperature Range: -22°F to 158°F (-30°C to Features 70°C) Photoelectric, integrated low-flow Operating Humidity Range: 0% to 95% relative humidity • technolo gy. (non-condensing), • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). 20.32 m/s). • Versatile mounting options: square or rectangular configu- Accessories ration. • Broad ranges for operating temperature (-4°F to 158°F, - Notifier provides system flexibility with a variety of accessories, 20°C to 70°C)and humidity(0%to 95%non condensing). including two remote test stations and different means of visi- 20°C Patented sampling tube installs from front or back of the b1e and audible system annunciation. As with our duct smoke detector with no tools required. detectors,all duct smoke detectors accessories are UL listed. • Cover tamper signal. DNR(W)s with a data code of 0013 or higher do not require external 24VD forremote test applications when used with a • Increased wiring space with a newly added 3/4" conduit re,note-test-capable detector. knockout. • Available space within housing to accommodate mounting ACCESSORY CURRENT LOADS AT24 VDC of a relay module. • Easily accessible code wheels on sensor head (sold sepa- DeY10p Standby i Alarm rately). RA1002 OmA 12mA Max • Clear cover for convenient visual inspection. Remote testing capability. RTS151/ • RTS151KEY OmA 12mAMax • Requires corn line power only. • Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL:S911,53705. • ULC: $635. DN-60429:C1•4/19/2012---Page 1 of 2 • CSFM: 3242-165.3:0209. ' ` '• FM approved. Product Line Information NOTE:"A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing, Requires photoelectric smoke detector(sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector(sold separately). FSP-851 R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100:Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels, DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft(0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A):Metal sampling tube duct widths up to 2 ft to 4 ft(0.5 to 1.2 m). DST5(A):Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX: Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151 KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. %get and FlashScan® are a registered trademark of Honeywell International inc. 02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. '. 0 9001 We try to keep our product information up-to-date and accurate. c E R F A ® We cannot cover ail specific applications or anticipate all requirements. ENCINEWNC 6 NIIN IACTIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in theU.S.A. For more information,contact Notifier.Phone;(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60429:G1•4/19/2012 dn-6935:c•H-202 0 0FSP-851 FSP-851T, & FSP1351R NOTIFIER ist-0 •0 Intelligent Plug.Irs Photoelectric by Honeywell Intelligent/Addressable Devices General Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously moni- tored and reported to the panel. Point ID capability allows *ease esee each detector's address to be set with decade address ese,e,„ ,eseetees ,Ae=ea'rfele switches, providing exact detector location for selective main- —seta,. a ea- - eas ves. tenance when chamber contamination reaches an unaccept- able level. The FSP-851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke pro- FSP-851 with B710LP base duced by a wide range of combustion sources. Dual electronic thermistors add 135°F(57°C)fixed-temperature thermal sens- ing on the FSP-851T.The FSP-851R is a remote test capable detector for use with DNR(W) duct detector housings. se,e'asese,I4sVseelai ,-0.7,•;4?:V::,-2.• .• FSP-851 series detectors are compatible with all ONYX series Notifier intelligent Fire Alarm Control Panels(FACP). ees,FlashScan®(U.S. Patent 5,539,389)is a communication pro- tocol developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the `400011101m115- devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The FSP-851T with B710LP base net effect is response speed greater than five times that of ear- lier designs. Features Specifications • Sleek, low-profile design. Size: 2.1° (5.3cm) high x 4.1" (10.4cm) diameter installed in * Addressable-analog communication. B501 base,6.1"(15.5cm)diameter installed in 8710LPbase. • Stable communication technique with noise immunity. Shipping Weight: 5.2oz. (147g). • Low standby current. Operating Temperature: FSP-851, 0°C to 49°C (32°F to • Two-wire SLC connection, 120°F); FSP-851T,0°C to 38°C(32°F to 100°F). Low temper- • FlashScan (NFS-320, NFS-640, NFS2-640, NFS-3030, ature signal for FSP-851T at 45°F +1- 10°F (7.22°C +/- NFS2-3030) and classic CLIP systems (AFP-100, AFP- 5.54°C).FSP-851R installed in a DNR(W),-20°C to 70°C(-4°F 200, AFP-300, AFP-400, NFS-640, AM2020/AFP1010, to 158°F), NFS-3030)compatible. UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 mi).),suitable for installation in ducts. on FlashScan systems). Relative Humidity: 10%-93%noncondensing. • Optional remote,single-gang LED accessory. Thermal Ratings: Fixed-temperature setpoint 135°F(57°C). • Dual LED design provides 360'viewing angle. • Visible bi-color LEDs blink green every time the detector is DETECTOR SPACING AND APPLICATIONS addressed, and illuminate steady red on alarm (RasftScan Notifier recommends spacing detectors in compliance with systems only). NFPA 72. In low airflow applications with smooth ceiling, • Remote test feature from the panel, space detectors 30 feet (9.144m) for ceiling heights 10 feet 148m) and higher. For specific information regarding • Walk test with address display(an address on 121 wili biink (dttector spacing, placement, and special applications refer to the detector LED: 12-[pause]-1(FlasnScan systems only). NFPA 72. System Smoke Detector Application Guide, • Built-in functional test switch activated by external magnet. document A05-1003,is available at systemsensor.com • Built-in tamper-resistant feature. ELECTRICAL SPECIFICATIONS • Sealed against back pressure. • Constructed of off-white Bayblend®, designed to commer- Voltage Range: 15-32 volts DC peak. cial standards,and offers an attractive appearance. Standby Current (max. avg.): 300pA @ 24VDC (one com- • 94-5V plastic flammability rating. munication every five seconds with LED enabled). • SEMS screws for wiring of the separate base. LED Current(max,): 6.5mA @ 24VDC(ON'). 1 • Optional relay, isolator,and sounder bases. BASES AVAILABLE NOTE: "A"suffix indicates ULC Listed model. . , . do-6935:c•3/12/10—Page 1 of 2 B710LP(A):6.1"(15.5cm)diameter. FSP-851T:Same as FSP-851 but includes a built-in 135°F B501(A):4.1"(10.4cm)diameter. (57°C)fixed-temperature thermal device. B200SR(A): Intelligent sounder base, configurable for temp-3 FSP-851TA:Same as FSP 851T but with ULC listing. or steady sound. FSP-851R: Low-profile intelligent photoelectric sensor, B224RB(A) Relay Base: Screw Terminals, up to 14AWG remote test capable. For use with DNRW. (2.0mm2); Relay Type, Form-C; Rating, 2.0A CO 30VDC resis- FSP-851 RA:Same as FSP-851R but with ULC listing. tive, 0.3A @ 110VDC inductive, 1.0A CC 30VDC inductive; Dimensions, 6.2" (15.748cm) x 1.2" (3.048cm) x 1,2" BASES (3.048cm). B710LP:Standard U.S.low-profile base. B224BI(A)Isolator Base: Dimensions,6.2"(15.748cm)x 1.2" B710LPBP:Standard U.S.low-profile base,pkg.of 10. (3.048cm) x 1.2" (3.048cm); Maximum, 25 devices between B710LPA:Standard U.S. low-profile base,ULC listing. isolator bases. 8501BP:Standard European flangeless base,pkg.of 10. Installation B501A:Standard European flangeless base,ULC listing. FSP-851 plug-in detectors use a separate base to simplify B200SR(A): Intelligent sounder base, configurable for temp-3 installation, service, and maintenance. A special tool allows or steady sound. maintenance personnel to plug in and remove detectors with- B224R8(A):Intelligent relay base. out using a ladder. Mount base on an electrical backbox which is at least 1.5" 8224B1(A):intelligent isolator base. Isolates SLC from loop shorts, (3.81 cm)deep. Suitable mounting base boxes include: • 4.0"(10.16cm)square box. ACCESSORIES • 3.5"(8.89cm)or 4.0"(10.16cm)octagonal box. F110:Retrofit replacement flange for older style bases. Con- • Single-gang box(except relay or isolator base). verts older high profile base for use with FlashScan detectors. • With B200SR base, use an appropriate junction box. RA100Z(A):Remote LED annunciator. 3-32VDC. Fits U.S. single-gang electrical box. Supported by B710LP(A)and • With B224RB or B224BI base, use a 3.5" (8.89cm)octago- 6501(A)bases only nal box,or a 4.0"(10.16cm)octagonal or square box. NOTE: 1) Because of inherent supervision provided by the SLC SMK400E:Surface mounting kit provides for entry of surface loop, end-of-line resistors are not required. Wiring "T-taps" or wiring conduit. For use with B501(A) base only. branches are permitted for style 4 (Class "8") wiring. 2) When RMK400:Recessed mounting kit. For use with B501(A)base using relay or sounder bases,consult data sheet DN-2243(ISO-X) only for device limitations between isolator modules and isolator bases. SM8600:Surface mounting kit for use with B710LP(A). Agency Listings and Approvals BCK-2008:Black detector covers,box of 10. For use with FSP-851 only. These listings and approvals apply to the modules specified in this document. In some cases,certain modules or applications WCK-200B:White detector covers,box of 10. For use with may not be listed by certain approval agencies, or listing may FSP-851 only be in process. Consult factory for latest listing status. M02.04-00:Test magnet. • UL Listed:51115 M02-09.00:Test magnet with telescope stick. • ULC Listed: S1115(FSP-851A, FSP-851 TA) XR2B:Detector removal tool. Allows installation and/or • MEA Listed:225-02-E removal of FlashScan Series detector heads from base in high • FM Approved ceiling installations. • CSFM:7272-0028:206 T55-127-010:Detector removal tool without pole. • Maryland State Fire Marshal: Permit#2122 XP-4:Extension pole for XR2B. Comes in three 5-ft.sections. • BSMI:01313066760036 • CCCF:Certif.#2004081801000017(FSP-851T) Certif.#2004081801000016(FSP-851) • Lloyd's Register:03/60011 CO l i r OL ' , Product Line Information rine*writa.aaxr ® r NOTE:'A or"CDN"suffix indicates ULC listed model, Not fiert9 and FlashScan®are registered trademarks of Honeywell Interna- FSP-851:Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. tional Inc. Bayblend®is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use FSP-851 A:Same as FSP-851 but with ULC listing. of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. EAR r M F o We cannot cover all specific applications or anticipate all requirements. IMPALING II NMMIIIMM IN1 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-dn-6935:c•3/12/10 DN-6724:B3 FCM-1 (A) & FRM-1 (A ® NOTI Fl Series Control and Relay Modules by Honeywell Intelligent/Addressable Devices General FCM-1(A)Control Module: The FCM-1(A)Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers,etc.).Addressability allows the FCM-1(A)to be acti- vated, either manually or through panel programming, on a select(zone or area of coverage)basis. tAssysi FRM-1(A)Relay Module: The FRM-1(A) Addressable Relay e Module provides the system with a dry-contact output ter apti . es e , vating a variety of auxiliary devices, such as fans, dampers, control equipment,etc.Addressabllity allows'the dry contact to "i' be activated, either manually or through panel programming, -***44 •" on a select basis. FlashScan®(U.S. Patent 5,539,389) is a communication pro • - tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- 146 gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates „x on single points.The net effect is response speed greater than five times that of other designs. FCM-1(A) Features • Built-in type identification automatically identifies these • The FCM-1(A)is configured for a single Class B(Style Y)or devices to the control panel. Class A(Style Z)Notification Appliance Circuit. • Internal circuitry and relay powered directly by two-wire • The FRM-1(A) provides two Form-C dry contacts that SLC loop.The FCM-1(A)module requires power(for horns, switch together. strobes,etc.),or audio(for speakers). • Integral LED "blinks" green each time a communication is Operation received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A)uses one of 159 possible module when activated. addresses on a SLC loop (99 on CLIP loops). It responds to • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- The FCM 1(A) may be used to switch 24 volt NAC power, tion Appliance Circuit (NAC). The LED blinks with each poll • received. On command, it activates its internal relay. The audio(up to 70,7 Vrms). FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) • Wide viewing angle of LED. notification or control circuits. • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- 01 —99 for CLIP mode loops. ply in the proper polarity across the load device. The • Speaker, and audible/visual applications may be wired for disconnection of the supervision provides a positive indication Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the corn- Applications munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. The FCM-1(A) is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The high-level audio (speakers). The FRM-1(A) may be pro- address may be set before or after mounting. The built-in grammed to operate dry contacts for applications such as door TYPE CODE (not settable)will identify the module to the con- holders or Air Handling Unit shutdown, and to reset four-wire trol panel, so as to differentiate between a module and a sen- smoke detector power. sor address. NOTE: Refer to the SLC Manual(PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL Specifications for FCM-1(A) datasheet(DN-60390)for new FlashScan@ releasing applications, Normal operating voltage: 15 to 32 VDC. Construction Maximum current draw: 6.5 mA(LED on). • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 pA direct poll,375 pA group • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 pA Max. (LED flashing, NAC address(01-159). shorted.) DN-6724:B3.2/17/2011—Page 1 of 2 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1(A) P External supply voltage(between Terminals T10 and Maximum Load Tii): Maximum (NAC): Regulated 24 VDC; Maximum CurrentVoltage DescriptionApplication (Speakers):70.7 V RMS,50W. Rating g Drain on external supply: 1.7 mA maximum using 24 VDC 3 A 30 VDC Resistive Non-Coded supply;2.2 mA Maximum using 80 VRMS supply. 2 A 30 VDC Resistive Coded Max NAC Current Ratings: For class B wiring system, the .9 A 110 VDC Resistive Non-Coded current rating is 3A; For class A wiring system,the current rat- ing is 2A. .9 A 125 VDC Resistive Non-Coded Temperature range: 32°F to 120°F(0°C to 49°C). .5 A 30 VDC Inductive Coded (L/R=Sms) Humidity range: 10%to 93%non-condensing. 1 A 30 VDC Inductive Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x (L/R=2ms) Coded 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125"(53.975 mm)deep box. Inductive 3 A 125 VAC (PF=O 35) Non-Coded Accessories: SMB500 Electrical Box;CB500 Barrier , _ I Inductive Specifications for FRM-1(A) 1.5 A 25 VAC (PF=0.35) Non-Coded Normal operating voltage: 15 to 32 VDC. Inductive Maximum current draw: 6.5 mA(LED on). .7 A 70.7 VAC (PF=0.35) Non-Coded Average operating current: 230 pA direct poll;255 pA group i poll. Inductive 1 2 A 25 VAC i(PF=0.35) Non-Coded EOL resistance: not used. Temperature range: 32°F to 120°F(0°C to 49°C) NOT I NOTMaximum(Speakars}:70.7 V RMS.50 W Humidity range: 10%to 93%non-condensing, Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x Product Line information 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x NOTE:'A"suffix indicates ULC Listed model. 2.125" (53.975 ma))deep box. FCM-1(A): Intelligent Addressable Control Module. Accessories: SMB500 Electrical Box;CB500 Barrier F IMI.1(4) 'intelligent Addressable Relay Module.,` Agency Listings and Approvals A2143-20: Capacitor, required for Class A(Style Z)operation of speakers. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult far- SMB500: Optional Surface-Mount Backbox, tory for latest listing status. CL850Q: Control Module Barrier--required by UL for separat- • UL; 5635 ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). • ULC:S3705(A version only) • FM Approved NOTE:For installation instructions,see the following documents: • CSFM:7300-0028:0219 • FCM-1(A)Installation document 156-1169. • MEA: 14-00-E • FRM-1(A)Installation document 156-3502. • FDNY: COA#6067, #6065 • Notifier SLC Wiring Manual,document 51253. Notifiere and PlashSeane are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use - of this document is strictly prohibited, Iso gaol This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E w r 1 o% We cannot cover all specific applications or anticipate all requirements. UMW SMmmf*c i1IM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.co i Page 2 of 2-DN-6724:83•2/17/2011 HN Series Effective November 2016 HS Series Technical Data TD450049EN Supersedes October 2014 ST Series Exceder Strobe, HoStrobe, and Horn Appliances Notification Description The Wheelock Exceder Series of notification appliances " feature a sleek modern design that will please building owners ,. T. , with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting ," . changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater m number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single a . appliance. Models with an audible feature 3 sound settings (90, 95, x 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. ' / Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. -* ''' The Wheelock Exceder Series of wall arid ceiling notification appliances feature a Universal Mounting Base (UMB) designed - to simplify the installation and testing of horns, strobes, and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the y. appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and e. damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. FAITeN Powering Business Worldwide Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series -Features • Environmentally friendly • Sleek modern aesthetics Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw@; • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings C>Patented • 90, 95, 99 dB Note: Please read these specifications and associated installation instruc- tions, before using, specifying,or installing this product.Visit Eaton.com/ • Industry leading-8 candela settings on 1 device massnotification for current installation instructions. • Wall: 15/1575/30/75/95/110/135/185 General Notes ▪ Ceiling: 15/30/60/75/95/115/150/177 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol Universal mooting base • Compatible with UL "Regulated Voltage" using filtered VDC or • unfiltered VRMS input voltage Ceiling and wall • Strobes produce 1 flash per second over the "Regulated Mounts to 5 backbox types: 1 gang, 2 gang,4" square, Voltage" range 3.5" octal. &4" octal. (100mm for international customers) Universal mounting base Contact cover Compliance UL. 1971, UL 464, ULC, CSFM, FM cat,- -f,:',. '"'''' - f = ::**-",i'"):"419704%.: ASA/��FPA/ANSI/QSHA 0. * '''''',°.v. ity 7: I -, t i ,:::1,34:10.',„,' ,:::::,>i.:;,,:s1.74:c'ik':::;:;::::::,::,,y;::::::;_,'-:::: .:_g.-' Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking (wall models only) t 0 0 : 2 EATON www.eamon,com HN Series Technical Data TD450049EN HS Series Effective November 201 6 , •Series - - 24 VDC/24 FlAfF1 12 VDC . - Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 . , . ST 8.0-33.0 0.057 0.070 0.085 --- 0 135 0.163 0.182 - 0 205 -- --- 0.253 0.110 0.140 SIC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 -- 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current®at Anechoic 99 ciBA - - 24 VDC 12 VDC - - - Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 1.44.010,41.00:1100101.11•1•111Mor HS 8 0-33.0 0.082 0.095 0,102 -- 0.148 0.178 0.197 - 0 242 - -- 0.282 0.125 0.159 HSC 8.0-33.0 0 082 -- 0.102 0.141 0.148 0 175 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current( at Anechuie 95 di3A - 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 50 75 95 110 115 135 150 177 185 15 15/75 ID. 4•1•1001011.00111110.0.... . HS 8.0-33.0 0.073 0.083 008/ -- 0.139 0.163 0.185 - 0.230 - -- 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0 128 0 139 •0.163 -- 0'I 8G --- 0.230 0.272 - 0.122 -1..11.Max Current(t)at Anechoic 90 48A - - - _ 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 6075 95 110 115 135 150 177 185 15 15/75 ......e. HS 8.0-33.0 0 065 0 075 0.0840.157 0 184 -- 0.226 - •-- 0.267 0.120 0.148 HSC 8.0-33.00065 .. . - 0 084 (11,10 0 136 0.157 - 0.184 - 0.226 026/ - 0.120 - (1)Ut.max current rating Is the maximum RMS current within the listed vrmagc range 115 33 VDC fur 24 VD)units).for strobes the li1 max current is usually at the minimum listed voltage 116 VI))for 24 V011 units) For audibles The max cur-ext ro usually at the maximum Stied voltage(34 VDC Int%4 VI))timiNI F07 unfiltered ratings,see Installation instruchons. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage -•-• " Model Range VDC 99 dB 95 dB 80dB HN - curio R . Red HN 16-33.0 0 064 0.644 0 022 ST - Strobe A = Agent Lettering(strobes only) HNC 16-33.0 0.084 0 044 0 022 1-1S = l'(orn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C 4 CE,,iling(\flaunt N = No lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0,017 r,w , White 1:-.0-mgle,1'SIA),---Strobo,Red,Ceiling Mount 1 Table 4, Specification&Ordering Information Example 2:HSR 4 Horn Stri)be,Red,Wad Moser ixamole 3. 13Wi •.•I loin Strobe,White,Wall Mount AN:lirimo;Velli?I'movt•to:r 12/24 M6z,ntin9 Exdrri.-16 4 51W-Al -ct 1.. While,Wall Mount,AlertLettering' vaca) optiono .., 1.)-. .--rune, Model Strobe Candela Supplies NOM Strobes .--,:: --4: .. -• FISH 15/1575/30/75/95/110/135/185 X X UM 8 0) ,...#"' ,,,,e.ir, .., ,".-•,..,",..4-,,,,;•;, , ,,,,,'' , • ,„.,,,,,t,l.c.,,,„:„..,,,,,:•., ,/g-;,* r,1::,‘;.• ••.;::: =,.• ll 7 l• 115W 15/1575/30/7S/95/110/135/185 X X U NI Br(l-7) 4:s:fl.7.•-.:4:---!.:. „ ,0,4,-,„ • ...,,, ,,,•• ..,-,..-.:.:,.:"..,,... ,,-!-•-•,•; ••:;,....A ,./.e; 11 SRC 15/30/60/75/95/115/150/177 X X L.8\rIB'ro ,,,.-,.....;•-•:1°'••••;/?;.1 -7-•.';l_Ffilr•4', '-,. f'''' • ILLI 1. ' 4, ',' HSWC 15/30/60/75/95/115/150/177 X X Li ilvIR(2) '•,...;.::/-.,:.;',.,,,,ill",,f,,•:-.,",,,.,:14.rfr,,,,,.; -;'..',.;:-• (2-; I 2• .-;;,,,,,A)14..,,s . 7,4.'`‘; ,• Strobes .:::;:,', :;;,:i,'-ir•---'.'.'''',--'-,--:--..„, .,:_';-4' ,, r1r0 '''''''''-117;:- '''' '.. - . , ..,', ':--:' '-i: -:.•<;;Nr-." ' •Z haft. V---:,:,:'' ,, _,' ,,,,,, ,. STR 15/1575/30/75/95/110/135/195 X X umacf, :;7i5 ::::::::- ;-- .; -: ;-...-. -. J.: - - *"..... ,,-;7:, .-''/,' --- -.- .. STW 15/1575/30/75/95/110/135/185 X X Li WI 0 ..,..,,,4, ,,,,,.,.;?„.• ,..„, - ,, ::17. ,„.•, i I %,,,, 0i • I/.. i • • ti. • A.A." 4,-' '.°;,:,.,-4,,,z•‘, `;"1* STRC 15/30/60/75/95/115/150/177 X X UIV1B(2.) ' t • r , .,' I • '.6. • ., ' STWC 15/30/60/75/95/115/150/177 X X urviBc--D ; - .., r.---f-; - t:- Horn RNA - ,:"-•'ll: ll .;-;•' -:l l''' '''.'"•,`.- '• X X 1.1M50 X UM ® HNRC ,, , ' ..• _;,.° ...,.. .,:.,-,,:', X X Ur/lB(S-;) Example. HSR Exarnple: HSWC HNWC ',`..•-,:l• ,- -, :ll...;.'.-:: :•l.,:s),/,';-4•:;"7. X X Ur/IBC') ®12 VI))models feature 155 i5/75 settings ®UrvIti 4 Universal Mounting Base EATON www.eatrui.00m 3 Technical Data TD450049EN HN Series Effective November 2016 HS Series ` ST Series -Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 C ia$s B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FRCP).The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wail Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.;dba Eaton standard terms and conditions. tatmaamm WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveiand,OH 44122 United States Eeton.rorn Eaton i.ife safety&mass notification'o!uti,'ns 273 Branchport Ave. Lon0Branch,NJ 01740 Eat on.co nt/rn a v rn ot!f i cat io n 2016 Eaton AT• All Rights Reserved Eaton is a registered trademark.Printed r USA Publication No.T040004�3EN At other trademarks.are property Powering Business Worldwide November 2016 of their respective owners. w . HN Series Effective November 2016 HS Series Technical Data TD450049EN Supersedes octc>ber 2014 ST Series Exceder StrStrobe,Hors Horn Notification Appliance Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners s with reduced total cost of ownership. installers will benefit from ; its comprehensive feature list, including the most candela options • in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal g mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high FRE efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe f models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a A voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Er A N Powering Business Worldwide Technical Data TD450049EN HN Series Effective November 2016 HS Series - . . ST Series -Features • Environmentally friendly • Sleek modern aesthetics Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw() • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings (1.) "P0''Pd .. 90, 95, 99 dB Note: Please read these specifications and associated installation instruc- tions,before using,specifying,or installing this product.Visit Eaton.com/ • industry leading-8 candela settings on 1 device msssnotification for current installation instructions. • Wall: 15/1575/30/75195/110/135/185 General Notes .. Ceiling: 15/30/60/75/95/115/150/177 • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C)and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock`'Sync Modules or panels with built-in W,'Vheeiock°Patented Sync Protocol • Compatible with UL "Regulated Voltage" using filtered VDC or • Universal mouting base unfiltered VRMS input voltage Ceiling and wall • Strobes produce 1 flash per second over the "Regulated • Mounts to 5 backbox types: 1 gang, 2 gang,4" square, Voltage" range 3.5" octal. &4" octal. (100mm for international customers) Universal mounting base Contact cover C®Mpiiae ' � ;v UL 1971, UL 464, Ut�2, CSFM, FM F, z , ` • ADA/NEPA/ANSI/OSHA T' ''',',%.54.. n Y4s a ' � �y , 2 i_. Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot chocking(wall models only) l 0 0 2 EATON www.eaton.com HN Series Technical Data TD450049EN HS Series Effective November 2016 - . .ST*5eries 24 VDC/24 FWR 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 -i 0.253 0,110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0,110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current@ at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage , Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 88-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0 242 0.282 - 0.125 - UL Max Current(S)at Anechoic 95 dBA . - 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 -- 0.139 0.163 0.186 -- 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current@ at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VOC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - 0.267 0.120 0 148 HSC 8.0-33.0 0.065 - 0 084 0.120 0 136 0.157 - 0.184 - 0.226 0.267 - 0.120 - C.)UL max current rating is the maximum RMS current within the listed voltage range(16-33 VOC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VOC units) For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage .4.111.1140. 40111111011•1•11111W Model Range VDC 99 de 95 dB 90 dB HN , Horn R = Red HN 16-33.0 0.064 0.044 0 022 ST = Strobe. , A = Agent Lettering(strobes only) .. ....... .. ...... ....... __. ...... .... ............... .. . . . . ._ HNC • 16-33.0 0.084 0.044 0 092 HS -,- Horn Strobe AL -..- Alert Lettering(strobes only) ,i... ... .... . _ .... ..... _ ............ .. ..... .. ........... . HN 8.0-17.5 0.047 0.026 0.017 C . Ceiling Mount N = No Lettering(strobes only) . . . ........ ....____ _ HNC 8.0-17 5 0.047 0.026 0.017 W --=, White __ _.......... . ........ .. .......... . . .............._. .. ..... . . . . . . . Example 1:STAG,,,Strobe,Reit Ceiling Mount Table 4. Specification&Ordering Information Example 2 HSR=Horn Strobe,Red,Wall Mount Example 3:HSW=Horn Strobe,White,Wall Mount 1st ihnece;lac 1E:7,Movrr 'a 12/24 Mounting Example 4.STW-AL,iii Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDCO Options Horn Strobes , .„. HSR 15/1 575/30/75/95/110/1 35/1 85 X X 1.11ME30) „.."'" ..,,-:,*•42 - -_ 3-,i,ii. ii....,•-r4 ,.„„ „.„..---' .-'' ‘ . :?. HSW 15/1575/30/75/95/110/135/185 X X (.1MB(i °' 7 ) ,ii._: . :v1IiI7i.--: ,r,,,,,•:,, i i HSRC 15/30/60/75/95/115/150/177 X X UMBC-') .„,- 'i'.: :- ' " ' -'. • i ow, HSWC 15/30/60/75/95/115/150/177 X X UMB,-(2) +.1 .1 . .i,,,,,7-. Strobes SIR 15/1575/30/75/95/110/135/185 X X ' Uft,IR a STW 15/1575/30/75/95/110/135/185 X X urviac, ,...... -; • ". . , • •. ,i,_-. - . . ,'•.„ 4, ;''''''",'?s: ''''• 4 STRC 15/30/60/75/95/115/150/177 X X UMB® 'i -.,;. - ,t- ' .,;'' ,4ir , I , STINC 15130/80115/95/115/150/177 X x UMB® .... ,,,.. , . ,,,, Horn , . , 7,-7,' . - HNR - 7 ' ; X X UMBQ) - HNW X UMB® .1'i 2:'... - X HNRC . i .. -' -- X X UMB® HSR Example: HSWC X UMB© 0 12 VDC models feature 15&15/75 settings Ci UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD45O049EN HN Series Effective November 2016 HS Series ST Series -Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan5''lens.The Series shall be of low current design.Where multi- candela appliances are specified, the strobe intensity shah have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP).The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible, The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes snail not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with VVheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RohIS Note:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. i, Member • WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY ■ Eaton 1000 Eaton,Boulevard Cleveland,OH 64 122 United Statoa Eaton.com Eaton i.Ife safety?+.press t,.otfirztinn,anlu'.ivns 273 Branchport Ave. Long Branch,NJ 07740 Eato orr'rnirnassno6fica5on 2016 Estop Ak Rights Roaerved Eaton is a registered trademark. EF ,T. Printed in USA Publication No.TD450046EN All other tr cternarks are property Powering Business Uhridwide November 2016 of their re {e,c ve owners.