Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (109)
CITY OF TIGARDII FIRE PROTECTION SYSTEM PERMIT 2 ' COMMUNITY DEVELOPMENT Permit#: FPS2017 00137 TtC3A:R.D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/06/2017 Parcel: 1 S 135AB03400 Jurisdiction: Tigard Site address: 10260 SW GREENBURG RD 1100 Project: Academy Mortgage Corporation Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Fire Sprinkler Permit:Plugging(3)sprinkler heads. Affidavit submitted. Contractor: PACIFIC FIRE SYSTEMS LLC Owner: LINCOLN CENTER LLC 6704 RIVERIA CT BY SHORENSTEIN PROPERTIES LLC WEST LINN, OR 97068 235 MONTGOMERY ST, 16TH FLOOR SAN FRANCISCO, CA 94104 PHONE: 503-710-6646 PHONE: FAX: FEES Description Date Amount Specifics: Permit Fee-COM 09/06/2017 $51.09 12%State Surcharge-Building 09/06/2017 $6.13 Type of Use: COM Plan Review-Fire Life Safety-COM 09/06/2017 $20.44 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 09/06/2017 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: .10 Design Area: 0 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Gales Provided: Cut Sheets Required: Total $78.16 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $500.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may .• .in a cop of the rules or direct questions to OUNC by calling 503.232.1987 or .. . - 344. -- Ale,r Issued By: - i Permittee Signature: _C:- —airs" M rdiP Call 503. 9.4175 by 7:00 a.m.for the next available inspection .,:'"e. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System ,0,04*10 FOR OFFICE USE OM.\ City of Tigard �� Received j 13125 SW Hall Blvd.,Tigard,OR 97223 � O Date/B : f/ Permit No.: s i _ l •`' Phone: 503.718.2439 Fax: 503.598.1960 ���71 „�Pk G�'�",; Other Permit: . 1 ',r`�f — -I - T 1 G A R D Inspection Line: 503.639.4175 V��� `'t ?ate Ready/By: .. See Page 2 for Internet: www.tigard-or.gov VA, ' Notified Method: , Supplemental Information TYPE OF WORK°1���V REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ddition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION : work indicated on this application. Valuation: $ ❑ 1-and 2-family dwelling Commercial/industrial j ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: /0,216 �1(../ 4,e ei444.42 ,d New dwelling area: square feet City/State/ZIP: (/' e-ti/2..- Garage/carport area: square feet .,ldg./apt.no.: //O 0 f Project name: /96-a 1/, Covered porch area: square feet Cross street/directions to job site: "�`� Deck area: square feet Other structure area: square feet REQUIRED DATA.COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. � r�i vl Ctc Valuation: $ L >! `.------- ---- 3&. ' Existing building area: square feet New building area: square feet 0 PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: 0 APPLICANT 0 CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed.If the City/State/ZIP: applicant is exempt from licensing,the following reasons apply: Phone:( ) Fax: :( ) E-mail: CONTRACTOR BUILDING PERMIT FEES* ,� 2C;4...< (Please refer to fee schedule) Business name: /oll f ,;c S y5 C � u . Permit fee: Address: c7 % 1't;1 Z'-t'�t'.4._ C City/State/ZIP: ' A / '� State surcharge(12%of permit fee): ty vv Ar H�t /v` FLS plan review(40%of permit fee): Phone:( e5.0-7/0 _t� Z/7 Fax:( ) (Due upon application submittal.) CCB lic.: / b a/y() AO Total permit fees: 7 /4 Amount received: Authorized signature: 6- This permit application expires if a permit is not obtained Print name: ,e4,.„. ��/ 7! Ute-` Date: ,'—�•f 7 within 180 days after it has been accepted as complete. C * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\FPS-PermitApp_031016.doc 440-4613T(11/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: El New system Number of sprinkler heads: Number of alarm devices: Addition or El 1-10 heads: Affidavit required and El 1-5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system ❑ 11+ heads: Plan review required and El 6+ devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work: Type of System(Complete A, ,C or D as applicable): A.) Commercial Sprinkler Sprinkler Type Wet El Dry Additional Standpipes Information: Sprinkler Supply Line ❑ Yes El No Hazard Group L -t Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I- Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations El Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler(Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq.ft. Fire Protection Permit Fees Project valuation subtotal (see A,B &C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review(40% of permit fee): $ TOTAL: $ I:\Building\Permits\FPS_PermitApp_031016.doc 2 City of TigardE' ermit No.: f/' i 7—a)/ 7 III • 13125 SW Hall Blvd.,Tigard,OR 97223 / IS Phone: 503.718.2439 Fax: 503.598.1960 ate Received: GI 6 /'7 Inspection Line: 503.639.4175 SEP TIGARD Internet: www.tigard-or.gov J L By: CITY OF TIGARD FIRE SPRINT IiF, ' FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: c Ply �� � 7 Occupancy: 1 Job Address: (©-LC O L- f. e'-e Type of Construction: Suite: //e)e) Contractor: /RC' is f2#-2 S7'S(e 5. Phone: Spry 3 -- 7/0 —I/ /� Number of Proposed or Altered Heads: Type: /,c,)t-7 Hazard: /9 A Density: .id I, ei fie-) , i6 Sr «�.y Oregon Construction Contractors Board No. /lO 19C) certify the following is true andVeasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams,partitions,walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop (exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this docu t with a copy of the sketch attached shall be available for all inspections. Air Ale Signature: Date: r _/7 Air Print Name: (j�',r¢ i' I:\Building\Forms\FireSprinklerAffidavit_071514.docx Page 1 of 1