Plans
GENERAL NOTES AERIAL VIEW 1. ALL WORK SHALL COMPLY WITH 2014 NATIONAL ELECTRIC CODE(NEC),2015 s' INTERNATIONAL RESIDENTIAL CODE(IRC),2014 NATIONAL BUILDING CODE(NBC),2015 % RAVEN INTERNATIONAL BUILDING CODE(IBC),2015 INTERNATIONAL PLUMBING CODE(IBC),AND % ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. % d� � • ° {+ 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. ( a - ggyyt � trII ; A SITE NOTES ' •. 1220 S.630E STE.430 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1, t , # + f %% & '=3 ti r AMERICAN FORK,UT 84003 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY _ *. ` r a : # 800-377-4480 INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 1 ' ' WWW.BLUERAVENSOLAR.COM 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING.MECHANICAL,OR .,r +s. � •. % ' {#€ .; d% J < CONFIDENTIAL-THE INFORMATION .1.,:::, BUILDING ROOF VENTS. ''''4:''.:111:-..'„..•1::; '' �' # Ake e # ' %: u 9 �" .. i n' i a 'y" ++31 HEREIN CONTAINED SHALL NOT BE 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL e• _(_ t :.:11): �° r, . r# USED FOR THE BENEFIT OF EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26] a` • g a • ' i ANYONE EXCEPT 9o- ,,f 5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE . . ` BLUERAVENSOLAR NOR SHALL IT BETWEEN THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER IF SMALLER THAN#6 � #r• d• � E DISCLOSED N WHOLE OR BPARTTNOTHERSOUTSIDEINAWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE CONDUCTOR WILL BE *, ?t y' k. RECIPIENTS ORGANIZATIN,CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER r' x % % + EXCEPTIN CONNECTION WIHTHE[NEC 250.64C.] *`$ ¢s " �� a . { SALEAND USEOFTHERES:C3H7E TIVElir r . ktlill � EQUIPMENT,WITHOUT 6. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH i 1 ' a r THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF WRITTEN PERMISSION% )17 ' 1::.,1.1•44fH4.„:,..-...ti,t,,::::1,,c;!, BLUERAVENSOLARLL COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. = u) $ { * s � 4s 7. RIGID CONDUIT(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. a�:# , • '_' + T O 8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED :31:'N'...; 4 ;, t r' '. p Q CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) ; ° r % # rf ` 0 Z d J 9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS s g ,,', - - 7 t, Q p DISALLOWED ABOVE LIVE PARTS,MEYERS HUBS RECOMMENDED •q r ,. _ * -�T •• % £ I ,fr xx= Z O Q 10. UV RESISTANT CABLE TIES(NOT ZIP TIES USED FOR PERMANENT WIRE MANAGEMENT OFF ; r : _ .> 'i @ 2 0 �' z c� ) % : t ;5114111,41i#41‘14 ! • a b %,� 0 THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B).300.4 a ) thiNVI,• r f. z ; O 11.SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE 1- p rF 7 � � s : [- M Q CSO MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. c :,' I d 7t { /V;,'` U O � { SOLAR CONTRACTOR amu % # A° x W I . criNFI, _ = .. ;� J 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730. a ' 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING l'i ,, *,, +� ' �„� 77 " ' . .: «:.. LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. �,i e„ .- ss itia:]' 4st 4 ase � ~xat s .......: -.--44'"'-.:: .n¢.,:...- •,.,?..... T LISTED MODULE GROUNDING DEVICES MAY BE USED _�• _ '1Rr:::a;�,,;-........_.<•....- .. ...._, 3. AS INDICATED BY DESIGN,OTHER NR LLS DOCUMENTATION 7 a. �• . °' • GROUNDING LUGS AS SHOWN IN MANUFACTURER . ,. :. ..a- I�_+,: .:� ,.�,.: F IN PLACE OF STANDARD GROU a,-�rn..,....;...a..:... ,. .s, d :. :.:.::,,:.::••:.•ac::::.:.......:. .,. :.. " .. . _. ....:�:;..mom. ... �....... s...... ,__ ....................._...,........ ........_. ._.v, _.._........:.,. *-�_ _.......:..... x.. . . x...:.r...........,...:. ....._.,_,._... . . . . �..v. ....,., , ..:...,.., 1. ..a...,,,,„....s.. ...' . ...,» a..E......_.»s..a.. .,,.:v..7 „ _. .......r•,... , ( J� f. t... ,. ,..., . .. ....sa: .,..,.a.. _� k._, .. ._.. ..:.............i.-c::aa.j s...;�..,., ..._ ,z......_.... , xs. ,,,.s`:... � `� .W :r;-:a::r: •t33•x:::::.u.• -�`, �...... ,,,,v,,:;::: . ... 3 .. -u_ .a sas. ..,. ...» ......... z&a_.;ew::, .....:.:.. 'a3� r._..._a...,.,....i.=_q�. .,a� k� .r. ._ . .,,. ;.»...... .. ... a_� AND APPROVED BY THE AHJ. ,� r , -- � I.:.. ., .,.it .:::h: ,. . .r,,,,,,r•:•a;^e'::::s:a;.3.::: :.• ., x. 'ix.. P" r'" ARE BASED ON MINIMUM CODE REQUIREMENTS AND :.. .... " ' 4. CONDUIT AND WIRE SPECIFICATIONS v ::.... .:::...,:•:::®-,::: :_::: : a:•= x.,. c ,,�,,:•t s«'!... :.......: . ..... : y., ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. "' I r `k'' }1 tt y� ; 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. ASCE 7-10 WIND SPEED: 110 MPH OCCUPANCY - R3 SHEET INDEX ARE 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. GROUND SNOW LOAD: 10 PSF CONSTRUCTION - V-B 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ EXPOSURE CATEGORY: C PV1 - COVER SHEET Z SUITABLE WIRING CLIPS. ZONING: RESIDENTIAL PV2 - PROPERTY PLAN p �, 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR SEISMIC DESIGN CATEGORY: D PV3 SITE PLAN t- N B VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, PV4 - EQUIPMENT &ATTACHMENT DETAIL N AC PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT SCOPE OF WORK PV5 - ELECTRICAL SINGLE LINE DIAGRAM Y j W (� COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER PV6 - ELECTRICAL CALCULATIONS 0 L > CL I- DC SYSTEM SIZE: 12.18 kW DC u_ SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). Y > O (n & STRING DIAGRAM Z (n 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. ROOF TYPE: Comp Shingle - ca EQUIPMENT LOCATIONS MODULES: (42) Sunmodule Plus SW 290M Black V7 MBD CL SA (IF NEEDED) H N INVERTER(S): En hase IQ6-60 2 US,---- PPV8 - LABELS & LOCATIONS - 0 c•; 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY[NEC 110.26]. P Y r- 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING RACKING: Iron Ridge XR100 PV Mounting & Racking System PV9 - STRING & SE OPTIMIZER TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND[NEC TABLE 310.15(B)]. PV1 O - PLACARD (IF NEEDED - NEC 690.56(B)) DRAWING BY 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT ANCHORED ON MAX 72 INCH CENTERS USING UL LISTED RACKING Jacob Harrs TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. COPY. 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING SYSTEM TO SPEC. (ODATE TO NEC APPLICABLE CODES. 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE CITY OF TIGARD August 16, 2017 WHEN APPROPRIATE. REY+ IEWE FOR CODE COMPLIANCE PROJECT NUMBER A roved: j 39767684 • PP OTC: SHEET NAME Pcrrnit#: ma4aai7'Qo=� o COVER SHEET Address: a W�� n PAGE NUMBER REVISION Suite#: PV 1 0 r. I , _ - ,.....,m1B- . ROOF ATTACHMENTS SHALL BE 72'-6" LEGEND SPACED NO GREATHER THAN 24" ON CENTER IN ANY DIRECTION NV NVERTER&DC DISCONNECT WHERE LOCATED WITHIN 3' OF A SAL sA ROOF EDGE, HIM, EAVE, OR RIDGE OSSC 3111.5.3 ITEM 3.44 LC (N)tE) LOA:Po CENTER 1220 S.630E STE 430 T 84003 AC AC DISCUBPONNET 800-377-4480 W W W.BLUERAVENSOLAR.COM ION BLUE RAVEN HEREIN CONTAINED SHALL NOT BE M UTILITY METER 1 SERVICE PANEL CONFAMERICAN IDENTIAL-FORK,THE INFORMATION MAT USED FOR THE BENEFIT OF N JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT I BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE I PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF /\ / I BLUERAVENSOLAR LLC. j, FIRE SETBACK \ / Q PV SOLAR MODULEigeli 0O 0 d MP1 ZoEt rn q � � N- 0 // O / o ' AZIMUTH: 1° < 0 7r Q Z 2 o EMT CONDUIT RUN fILI— PITCH:2O (TO BE DETERMINED IN FIELD) H O ' Oz < co �. / � TSRF:78% jj PV WIRE STRING W U U w j • jJ/ O rnx� I 0 J I i CO PROPERTY LINE AZIMUTH:181° 9111,1111c c l� 100-11 PITCH:20° I ' „ �� SCALE: 31 TSRF:89% c111111;alEi: ji3 \ �I::.:.:thll ( 4' JB MSP O 0 0 / JB O O C 4/7 25�91/ ai JB YIrY C) N AC .. U o V — � r N '1' C C ,_.. C 'C t U. UIH d _. 0 O 0, W Q �.. ' ..:1..: l L I � � ;. Z Y o to C tt) -2 co co to — �� N ,� 0 N AZIMUTH:181° JB PITCH:20° ..„_... C..... C.: ...�..,, ...:.._......0 � DRAWING BY Jacob Harm TSRF:89% MP3 AZIMUTH:181° DATE PITCH:20° August 16, 2017 TSRF:85% FRONT OF HOME PROJECT NUMBER DC SYSTEM SIZE: 12.18 kW DC 39767684 ROOF TYPE: Comp Shingle SHEET NAME (42) Sunmodule Plus SW 290M Black _ PROPERTY PLAN Enphase IQ6-60-2-US,----INVERTER PAGE NUMBER REVISION 12725 SW Walnut St PV2 0 LEGEND INV INVERTER&DC DISCONNECTBLUE RAVE N NSUB (E) SUBPANEL LC (N) LOAD CENTERil 1220 S.630E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUE RAV EN SOLAR.COM \ / M UTILITY METER(SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN \ / PART TO OTHERS OUTSIDE A 3' EXCEPT IN CONNEC TION WITH THE C COMBINER BOX RECIPIENTS ORGANIZATION, SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF c�, 9 PV PV REVENUE METER O r %// BLUERAVENSOLAR LLC. OInav v aniiiii i//i FIRE SETBACK CHIMNEY LLI LLJ 0J 0:. 0 : PV SOLAR MODULE �r_ti I- O 0t Quern UW 3' / // // 2H f— LUO • ,, EMT CONDUIT RUN z O _... ., CO O • (TOBE DETERMINED IN FIELD) D M 00 F=vii45iiiii2Eiiiiiiiiiii a'":'cii,11113^:'rsii'iii: _...,..........._....................._:•:._...:............._.... U '/ ///IOW 11,1111WIIA.E. ' PV WIRE STRING W Cl) LU MP4BRIES: o 1 AZIMUTH.181 3 .:. ' `.:...... :::::::::::: I ' di_ co �C �C O C JB �• � '4 ; PROPERTY LINE PITCH:20° MP1 TSRF:89% AZIMUTHo91° SCALE: 118"= 1' o.. .4.. . PITCH:20 0 JC d O TSRF:78% / JB MSP O j 0 O JBBB� Z 3j // ����/ ' ' F- `) S. N N �rGTc:. C N—AC ................. O L NrnW Ainiffili illEititialinfIROM „.„...., reliiima olsimiwili! _____„ nn �1. 1 l — c in U) 00 INITI.1 milli mom dam � • _ U (A Y .- I— CI DRAWING BY �6*. Jacob Harrs MP2 ° . ... C c c AZIMUTH:181FitirtillatiliiigiiiiiimainallinfiffitillIMEM N71 -6" DATE August 16,PITCH:20° .. . . TSRF:89% MP3 PROJECT NUMBER AZIMUTH:181° 39767684 DC SYSTEM SIZE: 12.18 kW DC PITCH:20° 1'-6" ROOF TYPE: Comp Shingle FRONT OF HOME TSRF:85% SHEET NAME SITE PLAN (42) Sunmodule Plus SW 290M Black Enphase IQ6-60-2-US,----INVERTER PAGE NUMBER REVISION PV3 0 PV ARRAY STRUCTURAL CRITERIA PV MODULE PV MODULE COUNT: 42 MODULES • Iron Ridge XR100 PV RAIL # OF ATTACHMENT POINTS: 80 -7.T___---------27—_ .w... ...J.__.._. _ 7-, _: RAVEN ARRAY AREA: Module Count X 17.51ft2 = 735.4ft2N NN N jrt r _111" ROOF AREA: 3438.4ft2 MAX. 72" MAX. 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 OF ARRAY/ROOF: 22.8% % ARRAY DETAIL, FRONT VIEW 800-377-4480 ARRAY WEIGHT: Module Count x 50Ibs = 2100.0Ibs ROOF TYPE: Comp Shingle Scale: 3/8" = 1'-0" WWW BLUERAVENSOLAR COM ROOF FRAMING TYPE: Manufactured Truss CONFIDENTIAL-THE INFORMATION DISTRIBUTED LOAD: Array Weight _ Array Area = 2.86 lbs/ft2 RAFTER OR TOP CHORD SIZE: 2x4 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF POINT LOAD: Array Weight T Attachments = 26.3Ibs/attachment RAFTER OR TOP CHORD SPACING: 24"O.C. Iron Ridge XR100 PV RAIL BLUERAVENSOLARNONE EXCEPT NOR SHALL IT CEILING JOIST OR BOTTOM CHORD SIZE: 2x4 ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C CEILING JOIST OR BOTTOM CHORD SPACING: 24BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE '~ RECIPIENTS ORGANIZATION. GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D 10"MIN FlashFoot2 EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE 1' 4" EQUIPMENT,WITHOUT THE flp MAX WRITTEN PERMISSION OF -""r IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL 10"MIN- --"`` �� BLUERAVENSOLAR LLC. IRONRIDGE UNIVERSAL FASTENING OBJECT 1'-4" == , FASTENING OBJECT '�/ 2'-8" MIN - o L o L o PV MODULE FRAME MAX 3' 10" MAX 20 W W Q Q d iv PV MODULE FRAM -:AW E ___\_ r ®_ IRONRIDGE RAIL Q co U O pr IRONRIDGE RAIL �i ,w..__.. " � JJ 2'-8"MIN ----- 3'-10" Q C0 d Z I _ 3' 10" MAX N I- W o0 F- Z ARRAY DETAIL, SIDE VIEW w 8 M oo DETAIL, END CLAMP FRONT Scale: 3/8" = 1 -O OO DETAIL, MID CLAMP FRONT 0 G Scale: 6"= 1'-0" Scale: 6"= i-o" IZ m PV MODULE Sunmodule Plus SW 290M Black • Iron Ridge XR100 PV RAIL PV MODULE _.!..__ -- > Iron Ridge XR100 PV IRONRIDGE 41'-11'MAX. RAIL 72" MAX. ARRAY DETAIL, FRONT VIEW z 0 I - w Scale: 3/8" = 1'-0" I- N (E)ROOF ROOF TYPE: Comp Shingle Q co 4" PI MEMBRANE ROOF FRAMING TYPE: Manufactured Truss I >I� RAFTER OR TOP CHORD SIZE: 2x4 W - rn W 0 RAFTER OR TOP CHORD SPACING: 24"O.C. 0L I— o CEILING JOIST OR BOTTOM CHORD SIZE: 2x4 Z t!') 0 } CEILING JOIST OR BOTTOM CHORD SPACING: 24 W . I,-N 2 U w , IPIron Ridge XR100 PV RAIL .--- -- 1—IRONRIDGE Y F FlashFoot2 3.5" MIN _ FLASHFOOT 10"MAX , DEPTHEi ASSEMBLY DRAWING BY 10"MAX Jacob Hairs FLASHING 20° DATE August 16, 2017 5/16"STAINLESS STEEL LAG � �/ 1'-8" BOLT AND FLAT WASHER � MIN. PROJECT NUMBER l'-8" 39767684 MIN. ARRAY DETAIL, SIDE VIEW (E) BUILDING 3/8" STRUCTURE Scale: = 1'-0" SHEET NAME EQUIP. DETAIL ® DETAIL, STANDOFF Scale: 3" = 1'-0" ROOF ATTACHMENTS SHALL BE SPACED NO GREATHER THAN 24" ON CENTER IN ANY DIRECTION PAGE NUMBER REVISION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIM, EAVE, OR RIDGE OSSC 3111.5.3 ITEM 3.44 PV4 0 (1) 6 AWG THWN-2r COPPER,BLACK(UNE 1) 4fI.32 A AC (3) SO AWG THWN-2,COPPER,BLACK[LINE 1) MAX 13.44 A DC (1} 10 3 NM-B W/G,COPPER MAX 13.44 A DC (1j 12-3 TC-ER,THWN-2,COPPER MAX 13.44 A DC 1c [1) 6 AWG THWN-2,COPPER,RED(LINE2p 240V AC (3] 10 AWG THWN-2, OPPER,RED'(LINE 2) 240 V pc 240 V DC [1j 5 AWG BARE,C€3PPER(ECC) 24th V 1]CNr°9' .l [1) 6 AWO THWN-2,COPPER,WHITE(NEUTRAL) (3) 10 AWG TI-IWN-2,COPPER WHITE(NEUTRAL) (1) 10 AWG TH WN-2,COPPER,GREEN(GROUND] (1) 10 AWG THWN-2,CAPPER,GREEN[ECC} (1) 3/4 EMTCONDUIT (1) 1"EMTCONDUIT VOLTAGEDRkCALCULATIONS CONDUCTOR CONDUCTOR VOLTAGE STARTING VOLTAGE AT {20 14 NEC CHAPTEROTABLEBj [T}IWN-2, IMP[A) LENGTH(FT} DROP(V) VULTAGE(V} END WI %DROP PV MODULESTO MICROINVERTER 10 9.33 3 0.07 3L4 31.3 0.22% 1220 S.630E STE.430 MICROINVERTER TOIUNGTION BOX 12 13.44 15 0.80 240.0 239.2 0.33 5 AMERICAN FORK,UT 84003 JUNCTION BOX TO COMBINER BOX 10 13.44 35 119 240 233.0 0.'1096 800-377-4480 COMBINER SOX TO INTERCONNECTION 6 40.3 5 0.21 240 239.8 0.09% WWW.BLUERAVENSOLAR.COM TOTAL%DROP 1.14% CONFIDENTIAL- THE INFORMATION U E HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF (42)Sunmodule Plus SW 290M Black ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT ii (42)Enphase IQ6-60-2-US MICRO BE DISCLOSED IN WHOLE OR IN INVERTERS PART TO OTHERS OUTSIDE UL 1741 COMPLIANT RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SUPPLY SIDE CONNECTION SALEEQU PMENusE O.WITHOUT THEEC ENPHASE I0 COMBINER JUNCTION BOX JUNCTION BOX _Z _2 (1) CIRCUIT �■■■ HE RESP et PER NEC 230.46,NEC 230.79(D), , ■■■ WRITTEN PERMISSION OF (E)200A MAIN SERVICE PANEL NEC 705.12(A) r _I— OF 14 MODULESMEW". BLUERAVENSOLAR LLC. (E)200A/2P MAIN BREAKER (N)20A/2P ' L,A u ill PV AC DISCONNECT X10 2el . C 0000 FUSED, AIC IOkA G G c~— I I W W d' Q Q d- (E)200A/2P LOCKABLE,VISIBLE OPEN r 1 G (r� z d- I 60A,240V,2-POLE I V Q z , U O • — z D C) Q ° C3 (� Cr M ki E � LOADS Q Lo, z 0 0 ( ) O JUNCTION BOX l_l 2 _ Z (1) STRING I■■■ 2 F- CO Z O 60A — I= OF 14 MODULES i .::- [— O CO O Q Ll CI D a (� FUSES — (N)20A/2P Lt ( Lt Li L1 L1 a.- L2 � W U U L2 --n---. .0 :, J G L2 L2 Lz f..'_ f/\ W N N nn N N N I Q V/ _EGG G G G 120/240 VAC v EL m iii 60HZ TO UTILITY GRID G 15 I �' 2 Z (1) STRING �-- JUNCTION BOX �I— O(1 14 MODULES ■ (N) LI r . G �� V L2 L2.I Ll L2�- - N N - (E) GROUNDING ELECTRODE O_ ,e ,ci. t ,.„,, . , ..,..77.,:,,,i1:-!'!,'i,r, [-- N tilll .: --, !'• N "r)I— a. �It : �' U i'4Li_ �_ > F- I. . , .. I t N VJ o0 11, .:.: 3 .;.! g ...7_,,,t"-;, DRAWING BY INTERCONNECTION NOTES i JaCOb HBFCS 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.95] 4:11. DATE 2. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. ' • k August 16, 2017 3. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)]WITH SERVICE x ENTRANCE CONDUCTORS IN ACCORDANCE WITH[NEC 240.21(8)] � F3 -P "*+ PROJECT NUMBER DISCONNECT NOTES 39767684 } 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE SHEET NAME TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) ELEC. 3 LIN E DAG- ''' 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH ... ? �( � PAGE NUMBER REVISION 3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO EITHER A FUSEABLE SOURCE CIRCUIT PV5 0 \le- MODULE SPECIFICATIONS Sunmodule Plus SW 290M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS B L U E R A E RATED POWER(STC) 290 W TEMPERATURE DATA SOURCE ASHRAE 0.4%HIGH TEMP MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.44 ADC MODULE VOC 39.9 V DC STATE Oregon JUNCTION BOX MAX.CURRENT(ISC X1.25)= 16.80 A DC MODULE VMP 31.4 V DC CITY Tigard CONDUCTOR(TC-ER, (90°C))= 12 AWG 1220 S.630 E STE.430 MODULE IMP 9.33 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A AMERICAN FORK,UT 84003 MODULE ISC 9.97 A DC ASHRAE EXTREME LOW TEMP(°C) -6 AMB.TEMP.AMP.CORRECTION= 0.91 800-377-4480 VOC CORRECTION(%/°C) -0.31 °C ASHRAE 0.4%HIGH TEMP(°C) 36 ADJUSTED AMP.= 27.3 > 16,:+1VVVVVN BLUERAVENSOLAR.COM VMP CORRECTION(%/°C) -0.44 °C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.44 A DC COONFID CONTAINED ENTIAL-THEINFORMATION HEON SERIES FUSE RATING 25 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 OR 5 CIR 6 COMBINER BOX MAX. CURRENT(ISC X1.25)= 15.80 A DC USED FOR THE BENEFIT OF ANYONE EXCEPT ADJ.MODULE VOC @ ASHRAE LOW TEMP 43.7 V DC NUMBER OF MODULES PER MPPT 14 14 14 CONDUCTOR(THWN-2,(90°C)= 10 AWG BLUERAVENSOLAR NOR SHALL IT ADJ.MODULE VMP ASHRAE 0.4%HIGH TEMP 25.5 V DC DC POWER RATING PER CIRCUIT(STC) 4050 4060 4060 CONDUCTOR RATING= 40 A BE DISCLOSED IN WHOLE OR IN @ PART TO OTHERS OUTSIDE TOTAL MODULE NUMBER 42 MODULES CONDUIT FILL DERATE= 1 RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE MICROINVERTER SPECIFICATIONS En phase IQ6-60-2-US STC RATING OF ARRAY 12180W DC AMB.TEMP.AMP.CORRECTION= 0.71 SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE POWER POINT TRACKING (MPPT)MIN/MAX 22 - 48 V DC AC CURRENT @ MAX POWER POINT(IMP) 13.44 13.44 13.44 ADJUSTED AMP.= 28.4 > 16.80 WRITTEN PERMISSION OF MAXIMUM INPUT VOLTAGE 48 V DC MAX.CURRENT(IMP X 1.25) 16.8 16.8 16.8 EGC MAX.CHANNEL ISC= 16.80 A DC BLUERAVENSOLAR LLC MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 20 20 CONDUCTOR(THWN-2,(90°C))= 10 AWG L >- O Lf p MAXIMUM USABLE DC INPUT POWER 330 W MAX.COMB.ARRAY AC CURRENT(IMP) 40.3 EGC CONDUCTOR RATING= 60 A W Z Tr Q J d- MAXIMUM OUTPUT CURRENT 0.96 A AC MAX.ARRAY AC POWER 10080W AC CONDUIT FILL DERATE= 1 Q Et co U 0 ti AC OVERCURRENT PROTECTION 20 A AMB.TEMP.AMP.CORRECTION= 0.71 Z D o < Z N- MAXIMUM OUTPUT POWER 240 W AC PHOTOVOLATIC MODULE MARKING(NEC 69052) ADJUSTED AMP.= 42.6 > 16.80 2 6 H W6 CEC WEIGHTED EFFICIENCY 97 % NOMINAL OPERATING AC VOLTAGE 240 V AC COMBINER BOX TO INVERTER RATED AMPS= 40.3 A AC U M Q a0 NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC MAIN PV OCPD MAX.CURRENT(RATED AMPS X1.25)= 50.4 A AC W 0 U IY PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) MAXIMUM AC POWER 240 VA AC CONDUCTOR(THWN-2, (90°C))= 6 AWG AC OUTPUT CURRENT 40.32 A AC MAXIMUM AC CURRENT 13.44 A AC CONDUCTOR RATING= 75 A a. -J m NOMINAL AC VOLTAGE 240 VAC MAXIMUM OCPD RATING PER CIRCUIT 20 A AC CONDUIT FILL DERATE= 1 AMB.TEMP.AMP.CORRECTION= 0.91 ADJUSTED AMP.= 68.25 > 50.4 GROUNDING NOTES STRANDED,AND BARE WHEN EXPOSED. USED TO PROTECT WIRE FROM SHARP EDGES . . 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 Z [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED.PER NEC, 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG INSULATED,90°C RATED,WET AND UV RESISTANT, RATED FOR 600V O W GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER N +. BONDED TO AT THE SERVICE ENTRANCE.IF EXISTING SYSTEM IS INACCESSIBLE, 11.GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLOR VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. N OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION CtW U GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS 0 i 6 CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED ASY �S 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66], DC FOLLOWS:DC POSITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED _LZ- ca > Y NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#8AWG WHEN GREY) W }c-, N � CO ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: ~ .(1) r-- 6 0 N 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 14.EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, DC POSITIVE-GREY(OR MARKED GREY), DC NEGATIVE-BLACK(OR MARKED BLACK) � Y R- 0 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN 12.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: DRAWING BY 690.46]. ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. PHASE A OR L1-BLACK, PHASE B OR L2-RED, PHASE C OR L3-BLUE, NEUTRAL- Jacob HBrrS 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC WHITE/GRAY 690.42]. WIRING&CONDUIT NOTES *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND BE USED INSIDE DATE THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR APPROVED FOR THE SITE APPLICATIONS **USE-2 IS AVAILABLE AS UV WHITE August 16, 2017 TO ANOTHER MODULE. 2.ALL PV CABLES AND HOMERUN WIRES BE#10AWG*USE-2, PV WIRE,OR 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS PROPRIETARY SOLAR CABLING SPECIFIED BY MFR,OR EQUIVALENT;ROUTED TO BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC PROJECT NUMBER IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 39767684 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 14.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 690.8] FOR MULTIPLE CONDUCTORS COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC SHEET NAME GROUNDING LUGS. 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE 330.30(B). ELEC. CALCS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND DERATED ACCORDING TO[NEC TABLE 310.15(B)(2)(a),NEC TABLE 310.15(B)(3)(a), GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT &NEC 310.15(B)(3)(c)] PAGE NUMBER REVISION BURIAL. 5. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV PV6 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE LABEL 1 LABEL 6 AT EACH DIRECT CURRENT JUNCTION BOX.COMBINER PHOTOVOLTAICAT DIRECT-CURRENT EXPOSED RACEWAYS. BOX,DISCONNECT.AND DEVICE WHERE ENERGIZED AN • CABLE TRAYS,COVERS AND ENCLOSURES OF UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING JUNCTION BOXES.AND OTHER WIRING SERVICE. POWER METHODS;SPACED AT MAXIMUM 10FT SECTION BLUE AV EN ELECTRIC SHOCK HAZARD [NEC.690.35(F)] OR WHERE SEPARATED BY ENCLOSURES, WALLS,PARTITIONS,CEILINGS,OR FLOORS. [NEC 690.31(G)(3&4)] THE DC CONDUCTORS OF1220 S.630 E STE.430 AMERICAN FORK,UT 84003 LABEL 7 THIS PUNGROUNDED SYSTEM PLACED CED CONSISTS ADJACENT TO THE LOAD SIDEACONED NECTION D BREAKERK FROM THE INVERTER IF NlYVV/gLUERAV 800-377-4480 R.COM ARE UNGROUNDEDANDIN MAY BE ENERGIZED INVERTER OUTPUT CONNECTION • [NEC 705.12(D>(2)(3>(b>j CONFIDENTIAL-THE INFORMATION DO NOT RELOCATE HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF THIS OVERCURRENT ANYONE EXCEPT BLUE RAVEN LABEL 2 DEVICESOLAR NOR SHALL IT BE OR IN PART FOR PV DISCONNECTING MEANS WHERE ALL DTO OTOHERS SED IN OUTS DEERECIPIENTS A TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. ORGANIZATION,EXCEPT IN LABEL 8 CONNECTION WITH THE SALE AND [NEC 690.17(E),NEC 705.22] USE OF THE RESPECTIVE SIGN LOCATED AT UTILITY SERVICE EQUIPMENT. EQUIPMENT,WITHOUT THE ELECTRIC SHOCK HAZARD PHOTOVOLTAIC S 1 STEIYF [NEC 690.56(C)] WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DO NOT TOUCH TERMINALS EQUIPPED WITH _ TERMINALS ON BOTH THE LINE AND ° w o Lf LOAD SIDES MAY BE ENERGIZED RAPIDSHUTDOWNW Z o < -1- O IN THE OPEN POSITION zoo) < 00 wh- LABEL 9(ONLY IF 3 OR MORE SUPPLY SOURCES TO A BUSBAR) < C0 � z R SIGN LOCATED AT LOAD CENTER IF CONTAINS 3 OR MORE POWER F— SOURCES. U O O Q pp �'+y /^��j j+� /� y(�+ �J� LABEL 3 [NEC 705.12(D)(2)(3)(C)] PHOTOVOLTAIC OLTAIC S i STEM AT EACH DC DISCONNECTING MEANS,INCLUDING THE THIS EQUIPMENT FED BY MULTIPLE W 0 0 '� DC DISCONNECT AT THE INVERTER. SOURCES TOTAL RATING OF ALL -7 W it DC DISCONNECT [NEC 690.53, NEC 690.13(B)] OVERCURRENT DEVICES,EXCLUDING m MAIN SUPPLY OVERCURRENT LL RATED MPP CURRENT AMPS DEVICE.SHALL NOT EXCEED AMPACITY OF BUSBAR. RATED MPP VOLTAGE VOLTS MAX SYSTEM VOLTAGE VDC MAX CIRCUIT CURRENT AMPS �y /�(, T J� SYSTEM LABEL 4 Z PHOTO Y©L �4IC DISCONNEAT POINT CF TING MEANS.INTERCONNECTION.MARKED AT AC LABELING DIAGRAM: O Lii 65 N A AC DISCONNECT [NEC 690.54,NEC 690.13(B)] Q c N 0/) MAIN SERVICE PANEL N RATED AC OUTPUT CURRENT A O �_ > - W 0 LL V '— NOMINAL NOMI OPERATING AC VOLTAGE INVERTER(S) Z Y > EXISTING SUB PANEL PV COMBINER (a - >- .. (IF WHERE POINT OF SUBPANEL- I J J } N O CO) co ® INTERCONNECTION IF USED TO COMBINE H 0 LABEL 5 CI ia.2...."; IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS Cn Y CV AT POINT OF INTERCONNECTION FOR EQUIPMENT Oik CONTAINING OVERCURRENT DEVICES IN CIRCUTS /�� r-�SUPPLYING POWER TO A BUSBAR OR CONDUCTOR O { 4) O I Q 7 + 7 ' DRAWING BY SUPPLIED FORM MULTIPLE SOURCES,EACH SERVICE v �..a t Jacob Harrs DUAL POWER SUPPLY EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION O O 0 SOURCE LOCATIONS. Ac JUNCTION BOX DATE SOURCES: UTILITY GRID AND [NEC 705.10 NEC 705.12(D)(3)] CD i� OR COMBINER BOX August 16, 2017 PV SOLAR ELECTRIC SYSTEM 9 °C O Cri ® O PROJECT NUMBER LABELING NOTES: (ONLY IF PV (ONLY IF PV O 0 O 39767684 1. LABELING REQUIREMENTS BASED ON THE 2014 NATIONAL ELECTRIC CODE,OSHA STANDARD INTERCONNECTION INTERCONNECTION ® ® CONSISTS OF LOAD CONSISTS OF LOAD �o 19010.145,ANSI Z535. SIDE BREAKER) SIDE BREAKER) SHEET NAME 2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC INTEGRATED DC DISCONNECT LABELS 110.21] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS 4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE, PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] REPRESENTATION OF PROPOSED SCOPE OF WORK. PV8 0 \Ow- LE RAVEN U U .0 obiN 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 `VU U 800-377-4480 la IIII2 WWW.BLUERAVENSOLAR COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE U o USED FOR THE BENEFIT OF ANYONE EXCEPT ail i BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION. U o EXCEPT IN CONNEC TION WITH THE ,cam SALE AND USE OF THE RESPECTIVE � !� EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC El O aC &C YC YCV la wL .1- o < � zCt DO Q � N- U C) < U 1 CC Z M Inc Flo Y c WU 0 CK U U -D CO LU MP4 a ..,44 Et AZIMUTH:181° a- co PITCH:20° JB MP1 AZIMUTH:91° MSP PITCH:20° JB C ,; o LU Q N N= JB � Flo rC UAC o L p �� i � Ct Zc - >- W co.. Nf0 FIG c Y c YC L CV r MDRAWING BY Jacob Harrs MP2 AZIMUTH:181° DATE August 16, 2017 PITCH:20° PROJECT NUMBER 39767684 MP3 JB ac Flo E c VAC YC AZIMUTH:181° SHEET NAME PITCH:20° SE Serial Layout PAGE NUMBER REVISION FRONT OF HOME PV9 0 -1/2 ,-,, ! CAUTION ! BLUE RAVEN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED . . SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: 1220 S630E STE430 AMERICAN FORK,UT 84003 800-377-4480 W W W.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF AC COMBINER BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT I BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE lumim PV ARRAYRECIPIENTS ORGANIZATION: EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PTEQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ®O BLUERAVENSOLAR LLC rilli9r1:11:101:11 ``oo w W .r O Qr� %Ell ra ZCC co eD rn Q3Or,. jvp4r,- �® F LO Z > c 0��0 // 00 in ° U w MAIN DISTRIBUTION a CO UTILITY DISCONNECT - AC DISCONNECT FRONT 12725 SW Wa, iut St, Tigard, OR 97223 z DIRECTORY 0 LLi PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF N THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC 2 = N r� SYSTEM DISCONNECTING. O > °' w o WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH Z 2 o } OTHER, A DIRECTORY I SHALL BE INSTALLED AT EACH DC PV w - N , oo SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING I— (- N a U N MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS (7) Y N i- 0 SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DRAWING BY DISCONNECTING MEANS IN THE BUILDING. Jacob Hairs ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC ENGRAVE DATE IN CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE August 16, 2017 ATTACHED USING AN APPROVEEMETHOD. IF EXPOSED TO PROJECT NUMBER SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE 39767684 WILL BE INSTALLED AS REQUIRED BY THE NEC. [NEC 690.56(B)] [NEC 705.10]. : SHEET NAME PLACARD .41„,.....4., PAGE NUMBER REVISION PV10 0