Plans ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. RECEIVED . CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. JUL 2 7 20117 (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, CITYOFTIGARD FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. BUILDING JJ1MIu GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp Isc CURRENT AT CIRCUIT CURRENT COMPLY. 250.97, EITHERDO(NOT ENTER OFFICE COPY kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC ' CITY OF TIG►ARD LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). FOR CODE COMPLIANCE MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY Approved: NEUT j NEUT NEUTRAL UL LISTING. OTC: NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE , Permit#: OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE I�S'�'aQ 17 - 0 .. 7 PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING Address: 1 43 ‹ A. ,5‘,,, g g ' JaVe_ P01 POINT OF INTERCONNECTION HARDWARE. Suite#: PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE Date: SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. By: F-a- j -2 S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL • UPS--UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC AND 2012 IBC. RGC, CGC1 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON ELECTRICAL SPECIALTY CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Tigard W t N REV BY DATE COMMENTS mci=3 DATE COMMENTS ©©© UTILITY: Portland General Electric l ©©©© 00 � = t ©© CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9723734 00 PRESS OM: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: CHAD CAMPBELL Chad Campbell RESIDENCE JeremyNguyen `�•t�a } NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 14368 SW 88TH AVE 4.2 KW PV ARRAY ►„Solar Ci ly PART TO OTHERS OUTSIDE THE RECIPIENTS p YP •,,`� TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-300DDO5A.18(11) 3055 Clearview Way r SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 INVERTER: PERMISSION OF SOLAROTY INC. 7:(850)638-1028 F:(650)638-1029 ABB, PVI-3.0—OUTD—S—US—Z—A COVER SHEET PV 1 a 7/7/2017 (888)—SOL—CITY(765-2489)www.edaraitycom PITCH: 40 ARRAY PITCH:40 MP3 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories Yw PITCH: 40 ARRAY PITCH:40 -ga MP4 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories LEGEND Front Of House Q (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO 11 & WARNING LABELS r"• " ® ® \ 12"FM_ N-1 DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS a' ® Q DC JUNCTION/COMBINER BOX & LABELS L M L •MP3 __-,,.._,,..„-_____4 ao 0 t o ►, -� _=_�.y,_.;��.a D DISTRIBUTION PANEL 8c LABELS N (E)DRIVEWAY 0 Lc LOAD CENTER & WARNING LABELS M O O � DEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN O ` I STANDOFF LOCATIONS 0 CONDUIT RUN ON EXTERIOR M F CONDUIT RUN ON INTERIOR c, GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED It 'I INTERIOR EQUIPMENT IS DASHED SITE PLAN N TOTAL ARRAY AREA (SF): 252 Scale: 3/32" = 1' TOTAL ROOF AREA (SF): 2362 w m E TOTAL ARRAY AREA IS a 10.66 01' 10' 21' PERCENT OF TOTAL ROOF AREA I••- s CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9723734 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE CHAD CAMPBELL �l1d BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Chad Campbell RESIDENCE Jeremy Nguyen �� �SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 14368 SW 88TH AVE �'� PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type c 4.2 KW PV ARRAY rte ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-300DD05A.18(II) 3055 OearvIew Way " SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAIL: SHEET: REV: DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. T:(650)638-1028 F:(650)638-1029 ABB# PVI-3.0-OUTD-S-US-Z-A SITE PLAN PV 2 a 7/7/2017 (888)-soL-aly(765-2489)www.ealarc8y.com PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS — LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ® PRESAllie.A14 STRUCTURE MEETS THE CRIPTIVE REQUIREMENTS ZEP ARRAY SKIRT (6) HOLE. OF THE OSSC SECTION 3111 (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C — POLYURETHANE SEALANT. ZEP FLASHING C ��AlFi�,���� �F1'.•J *�`��� illif. (3) INSERT FLASHING. II 12'-3" 1-.� (E) LBW (E) COMP. SHINGLE v�WV] �� (4) PLACE MOUNT. SIDE VIEW OF MP3 NTS (E) ROOF DECKING INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) ( ) SEALING WASHER. MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES ( ) INSTALL LEVELING FOOT WITH LANDSCAPE 72" 24" 39" 0" STAGGERED WITH SEALING WASHER 6 BOLT & WASHERS. PORTRAIT 48" 20" 64" 0" (2-1/2" EMBED, MIN) ROOF AZI 180 PITCH 40 RAFTER 2x8 @ 24"OC STORIES:2 (E) RAFTER ARRAY AZI 180 PITCH 40 STANDOFF C.J. 2x8 @24"OC Comp Shingle 5X ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. I) X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. Scale: 1 1/2" = 1' :* STRUCTURE MEETS THE OAPRESCRIPTIVE REQUIREMENTS OF THE OSSC SECTION 3111 (E) LBW D SIDE VIEW OF MP4 NTS MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 39" 0" STAGGERED PORTRAIT 48" 20" 64" 0" RAFTER 2x8 @ 24"OC ROOF AZI 180 PITCH 40 STORIES:2 ARRAY AZI 180 PITCH 40 C.J. 2x8 @24"OC Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. JB-9723734 0 0 PREMISE OMMER DESCRIPTION: DESIGN: CONTAINEDCONFIDENTIAL A THE INFORMATIONBSEDFOREToe NUMBER: CHAD CAMPBELL Chad Campbell RESIDENCE JeremyNguyen �.��la • EFIT OF SHALL NOT EXCEPT USED NE \` SolarCit BENEFIT ANYONE SOLARCITY INC., MOUNTING SYSTEM: p '•„` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14368 SW 88TH AVE 4.2 KW PV ARRAY ►�� • PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH NE SALE AND USE OF NE RESPECTIVE (14) TRINA SOLAR # TSM-300DDO5A.18(II) 3055 28 w Way ' SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REN DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITYMENT, INC. 7:(650)638-1028 F:(650)638-1029 ABB# PVI-3.0-OUTD-S-US-Z-A STRUCTURAL VIEWS PV 3 a 7/7/2017 (888)—SOL—CITY(765-2489)www.ealarcity.aam 07.07.2017 Version 568.9 DESIGN SUMMARY • Design Code E710 • Ulttrnate Wind Speed V UI5 trat 9it aria,, '." .. L'i ‘ur• Mound Snow Load 5 .. ;:.. =tee € .791 .! .t [.s. ':.� �E"2� [ 211 . pet ASCE Table 7 9 d w,n 4111 74TIF.) er.. € a ®L 8.,s - fig.,, r MP Name MP3 MP4 ✓ iirki:.1=7.atil-Mf=ln..:2=Ezgurl, €„u Standoff Comp Montt Type C Comp Meant Type C f4.� m SLJRLL•PV 25.0• 25.0• INP Name MP3 MP4 3• X-Cantilever 24 24' Y-Cantilever NA NA aB-a '�' �Aall� Wlll111l1 � I -= X-Cantilever 20” 20" 7 3'„ a _E �'. Y-Cantilever NA NA 11, twat- X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters.. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9723734 0 0 PREMISE OWNER: DESCRIP71ON: DESIGN: CONTAINED SHALL NOT BE USED FOR THE �! ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTWG SYSTEM; CHAD CAMPBELL Chad Campbell RESIDENCE Jeremy Nguyen �„� t� 'ar '�" NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 14368 SW 88TH AVE �'" y PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 4.2 K W P V ARRAY h. • ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TIGARDj OR 97224 THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-300DDO5A.18(II) 3055 ClearCew Way - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NVERTER: PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. T:(650)638-1028 F:(650)638-1029 ABB# PVI-3.0—OUTD—S—US—Z—A UPLIFT CALCULATIONS PV 4 a 7/7/2017 (688)-SOL-CITY(765-2489)www.solarcity.aom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) 18 GEC TO TWO (N) GROUND Panel Number:BR2040B200 Inv 1: DC Ungrounded INV 1—(1)ABB# PVI-3.0—OUTD—S—US—Z—A LABEL: A —(14)TRINA SOLAR I TSM-300DD05A.18((II RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:25043610 FCI Inverter; Zigbee 3000W, 240V, 96% PV Module;300W,270.6W PTC,40MM,B(k Frame,MC4,ZEP,1000V,Wht BckSht Underground Service Entrance INV 2 Voc: 39.9 Vpmax: 32.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! (E) WIRING Inverter 1 IND 200A 2P 0 ABB 1 DC+ Vstart= 200V / PVI-3.0–OUTD–S–US–Z–ADC- MP3: 1x7 9 •R (E) LOADS EGC Cril IN Li 1 240V 1 I— i I • • •� DC* I d N m 20A/2P EGC/ DC. I 2DC+ Vstart= 200V m �� – GEC –––1� �� DC- DG MP3,MP4:1x7 j B I 1 GND I____EGC_—_ ___–f _ GC J I I, N –L — J EGC/GEC Z–Z C9 -----GEC –r-1 TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I I I II I I I I I I i I i I Voc* = MAX VOC AT MIN TEMP POI (1)CUTLER–HAMM R BQC 202115 PV BACKFEED BREAKER AC Breaker, 15A�1P-2OA 2P-15A/1P, 2 Spaces, Quadplex –(2)rondxRo Copper DC 5/8 opP (1)AWG#10, T1-1WN-2, Black (2)AWG#10, PV Wire,600V, Black Voc* =310.08 VDC Isc =9.64 ADC O I (1)AWG#10, THWN-2, Red O LLLL�I (1)AWG#10, THHN/THWN-2,Green EGC Vmp =228.2 VDC Imp=9.19 ADC L666 (1)AWG#110, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC 1 Conduit Kit; 3 4' EMT –(1)AWG/8, THWN-2, Green EGC/GEC–(1)Conduit Kit; 3/4'EMT ( ) WG#10, PV i.W. . 0V,WG#10 Voc =310.2 VDC Isc =9.64 ADC i-21–(1)AWG/10, THHN/THWN-2, Green EGC Vmp =228.2 VDC Imp=9.19 ADC (1)Conduit Kit; 3/4' EMT 1 CONFIDENTIAL– THE INFORMATION HEREIN JOB NUMBER: JB-9723734 00 PREMISE OWNER: DESCRIPTION: DESIGN: \‘` CONTAINED SHALL NOT BE USED FOR THE CHAD CAMPBELL Chad Campbell RESIDENCE JeremyNguyen ,f'`r BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: P �.,'°SolarCityNOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14368 SW 88TH AVE 4.2 KW PV ARRAY PART TO OTHERS OUTSIDE NE RECIPIENTS MODULES: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH r NE SALE AND USE OF NE RESPECTIVE (14) TRINA SOLAR # TSM-300DDO5A.18(II) 3055 Cleo-view Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: T:(650)Son 636-1028,CA 94402 INVERTER: F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0–OUTD–S–US–Z–A THREE LINE DIAGRAM PV 5 a 7/7/2017 (888)–SOL–CITY(765-2489)www.solarcity.com Label Location: Label Location: Label Location: CAUTION SOLAR'CIRCUIT (C)(IC)(CB) MAXIMUM AC - A (AC)(P01) WARN NG (P01) Per Code: OPERATING CURRENT Per Code: Per Code: MAXIMUM AC INVERTER OUTPUT IFC 605.11.1.4 _ V NEC 690.54 NEC 690.64.6.7 OPERATING VOLTAGE CONNECTION • DO NOT RELOCATE Label Location: THIS OVERCURRENT PHOTOVOLTAIC DC (DC)(INV) DEVICE DISCONNECT Per Code: NEC 690.14.C.2 Label Location: WARNING (AC) (POI) Per Code: Label Location: ELECTRIC SHOCK HAZARD 17 NEC 690. 4 WARNING Label Location: DO NOT TOUCH TERMINALS ( ) (DC)(INV) (DC)(INV) TERMINALS ON BOTH LINE AND Per Code: MAXIMUM POWER- LOAD SIDES MAY BE ENERGIZED ELECTRIC SHOCK HAZARD POINT CURRENT(Imp) * NECCode: IN THE OPEN POSITION THE DC CONDUCTORS OF THIS NEC 690.35(F) MAXIMUM POWER- PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT VOLTAGE(Vmp)-v NEC 690.53 UNGROUNDED AND MAXIMUM SYSTEM MAY BE ENERGIZED INVERTER IS VOLTAGE(Voc)_V UNGROUNDED SHORT CIRCUIT CURRENT(Isc)-A Label Location: PV SYSTEM (AC) DISCONNECT FOR s` UTILITY OPERATION Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code' DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (POI) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING. ELECTRIC SHOCK DC VOLTAGE IS HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE ' BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE Label Location: MAIMUCURRENT - A OPERATING CURRENTNT WARNING (DC)(INV) MAXIMUM AC Per Code: OPERATING VOLTAGE V ELECTRIC SHOCK HAZARD NEC 690.5 C IFA GROUND FAULT IS'INDICATED ( ) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 Label Location: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC AC (AC)(P01) (AC): AC Disconnect (C): Conduit DISCONNECT Per Code: (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel Label Location: (DC): DC Disconnect CAUTION (D) (P01) (IC): Interior Run Conduit Per Code: PHOTOVOLTAIC SYSTEM NEC 690.64.6.4 (INV): Inverter With Integrated DC Disconnect CIRCUIT IS BACKFED (LC): Load Center (M): Utility Meter (P01): Point of Interconnection Label Set ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4 Ze Soar 3/26/15 p C tar 3/26/15 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing= calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Load Duration Wind Snow �eA design load landscape= 15.35 27.64 27.64 psf Uplift= 656 lbs N/A Fr:4.4.iy,�.".,r'!C` ; design load portrait= 12.28 27.64 27.64 psf Lateral= 357 lbs 290 lbs !417 B note:use 10 psf minimum Down Force= 1074 lbs 771 lbs Snow Calculations To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment Spacing;Calculationsgo Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 degrees. Uplift Spacing EXPIRES: 12/31/16 Allowable Uplift Load FOR PAGES 1-4 uplift spacing = Ground Snow Load= 30 psf module length or width x design load Roof Pitch Wind Uplift Calculations 14 30 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf p=qn GCN (snow load spread over the length of the rafter) qh=0.00256 Kz KZt Kd V2 l Basic Wind Speed= 120 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 D+S= 31.16 25.10 psf Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof Kzt= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.755 31.59 , 1.9i psf Vorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force iscape effective area= 13.0 ft2 GCN portrait=-1.5 7711bs in iortrait effective area= 21.7 ft2 landscape down force spacing= 39"x 31.91psf x 144 ft2 =89" Piandscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf 7711bs in portrait down force spacing= 65"x 31.91psf x 144 ft2 = 53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf 656 lbs in landscape uplift spacing = 39"x 27.73 psf x 144f-t2 44 ftz = 87" 656 lbs in portrait uplift spacing = 65"x 25.89 psf x 144 ft2 =56" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 3/26/15 3/26/15 ZepSotar oar Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load Maximum Uplift Pressure Landscape= -27.73 lateral spacing = p P module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf PS=C5 pf Roof Pitch= 31 45 degrees landscape module spacing = -1.4545 x 31.91 psf+120.7273 = 74" pf=0.7 Ce Cf l pg Ce= 0.9 C5= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing=-0,8182 x 31.91 psf+79.909= 54" I= 1.0 p,= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing Spacing Check 27 30 31 45 Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral 30' 27"' 30"* Lateral Force Component 74" 4r, " '44"-j Down Force Load Roof Pitch Module Deflection " 54" Combinations: 27 30 31 45 D+S= 13.50 '14.49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 2901bs landscape lateral spacing= 39"x 14.49 psf x 144f-t2 44 in =74" 2901bs in portrait lateral spacing= 65"x 14.49 psf x 144 ftz =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2901bs in portrait lateral spacing= 65"x 13.50 psf x 144 ftz =48" 4,.,, 0 ,, -,itSolarCity ZepSolar Next-Level PV Mounting Technology ''4SoiarCity ZepSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs €- ��f 4`' ,ra '+ 9 . _ ' Leveling Foot Irtoak Part No.850-1172 ETL listed to UL 467 r4 q - , r„ , I � F M4wM11 -V i . 1 Zep Groove _". Array Skirt . Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 tttMPAT- ti� e� Description �; 11111141 • PV mounting solution for composition shingle roofs �t y 'm,,®0� - Works with all Zep Compatible Modules b OMPA • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 kk . • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, zepsolar.com zepsolar.com List d o0,L 156567 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications am subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Solar inverters Additional highlights - RS-485 communication interface (for connection to laptop or data ; logger) rvv � - Available with the optional VSN300 Wifi Logger Card for easy and �, ,� affordable wireless monitoring �� ,.°, . �' - Compliant with NEC 690.12 when used with ABB's Rapid Shutdown device 11512111; 2'51M11:1;!ir-Pl!l!lit;IPI. - Comes standard with DC Arc Fault Circuit Interruptor(AFC')to comply with NEC 690.11 I' ,,ig Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ME Nominal output power3000W 3600W 3300 3800W 4200W W Maximum output power wattage 3000 3300' : 3300' 3600 4000 4000' 3300 4200 4200' : 4200 : 4600' 4600' "; W W W W W W W . W W • W W W Rated rid AC volts e 208V • 240V . 277V 208V 240V 277V 208V ! 240V 277V 208V 240V 277V input. T,t" 217 [ .7 '.""CM?1,i a 4141N,,„„,,,,, ,,, Number of independent MPPT channels 2 2 2 2 Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) ..... 200V(ad..120-350V) Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V ............................... ,,' Operating MPPT voltage range 0.7 x Vstart 580V(>90V) Maximum current(Idcmax)for both MPPT in 20A 32A 32A 32A parallel,,,, Maximum usable current per channel 10A ; 16A 16A 16A '. Maximum short circuit current limit per 12.5A 20.0A 20.OA ! 20.0A channel Number of wire landing terminals per channel ..... .. .... 2 pairs .. .. ... . Array wiring termination Terminal block,pressure clamp,AWG20 AWG6 'Ide3 ' „lifik_=_ L' �-� —x �wtt»tE�t��-->a.:t - .r..n.•.„+M""`° Grid connection type 10/ Split ; 10/ : 10/ .Split 10/ 10/ Split- '10/ 10/ Split- 10/ ........ . ............. ........... : 2W 0/3W 2W ......2W 0/3W ! 2W 2W 0/3W 2W 2W 0/3W . 2W 1it Ad ustable volts a ran e mm-Vmax 183- 211- I 244- i 183- 211- : 244 183 211- ' 244- 183 211- 244- Adjustable t g g )M _ 228V 264V 304V 228V .„264V 304V 228V..,.264V ; 304V 228V 264V304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(1„,°°„) 14.5A 14.5A 12.0A 17.2A 16.0A 16.0A 16.0A 16.0A 16.0A 20.0A 20.0A 20.0A Power factor >0.995(adjustable to*0.8) This family of single-phase string The high-speed MPPT offers real- Highlights Total harmonic distortion at rated power l.. ,.. <2% inverters complements the typical time power tracking and improved - Single-phase and three-phase output Grid wiring termination type Terminal block,Pressurecl amp...................................................................................._................. AWG20 AWG6 number of rooftop solar panels energy harvesting. grid connection in 9t s s :,;.911,-..1 „.",„: t ' ''''''-:', ".,..7- '- ,, ”, enabling homeowners to get the most The flat efficiency curve ensures high- - Wide input-voltage range for Reverse polarity protection Yes Over voltage protection type Varistor,2 for each channel efficient energyharvesting for the size efficiency at all output levels allowing increased stringing flexibility and PV array ground fault detection Pre start-up R and dynamic GFDI(requires floating arrays) totectton d”' t'� E of the property. a consistent and stable performance energy harvesting � �- �,�•� � [..:I€ �" s '" _ -azt1c„Ili' ir - _ti Anti islanding protection Meets UL1741/IEEE1547 requirements across the entire input voltage and — The high-speed and precise MPPT Over-voltage protection type..._ Varistor,2(L, L2/1,-G) This inverter offers a dual input output power range. algorithm offers real-time power Maximum AC OCPD rating 20A . 20A 15A 25A 20A 20A 20A i 20A . 20A I 25A 25A 25A section that processes two strings The transformerless operation gives the tracking and improved energy clenr .44'.'.'(:',.:' -= 9n r:,, t'L --:-.X. with independent Multiple Power Point highest efficiency of up to 97.0 percent. harvesting Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% Tracking(MPPT). The wide input voltage range makes - Outdoor NEMA 4X rated enclosure -O er a ° e _ t,, r This is especially useful for rooftop the inverter suitable to low-power for unrestricted use under any Nighttime consumption <0,6WA„a installations with two different installations with reduced string size. environmental conditions Stand-by consumption <aw _R orientations from two sub-arrays This rugged,outdoor inverter has - Integrated DC disconnect switch User interface 16 characters x 2 lines CD display oriented in different directions,or been designed to be a completely in compliance with international Remote monitoring(1xRS485 incl) VSN700 Data Logger(opt.),VSN300 Wifi Logger Card(opt.) unbalanced strings(for example:East sealed unit,to withstand the harshest Standards(-S Version) tat °s°`[,", " ";„ `-5 ;:: - r ' Ambieentnt airir operating temperature range -13°F to+140°F(-25°C to 60°C)with derating above 122°F(50°C) and West). environmental conditions. Ambient air storage temperature range 40°F to+176°F(-40°C to+80°C) The dual-input sections with Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)@lm AL ID II Maximum operating altitude without derating 6560ft(2000m) optimal energy harvesting condition. Power and productivity Capability enabled at nominal AC voltage and with sufficient DC power mailable mm fora better world'” ar-a El"NIP 2 ABB solar inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD Block diagram of PVI-3.0/3.6/3.8/4.2-TL-OUT Support and service For more information please contact ©Copyright 2015 ABB.All rights "'2"'� �; a s nXL, �aoa�aAUE, ABB supports its customers with a your local ABB representative or visit: reserved.Specifications subject to "' t❑ ❑+ ❑ ❑ a -❑ ,�� fic dedicated,global service organization change without notice. '' "' '" "' I "' ; " in more than 60 countries,with strong www.abb.com/solarinverters "' '❑ , ❑_ ❑ ,`,1011 ■ 4-,,i,,,-q ) tivitz • regional and national technical partnerEi }; � I I----t networks providing a complete range of www.abb.com ° r • Ili life cycle services. ,Nz.aap ❑ ❑ r � . , li = acaou r � 0 4��' : 1IPP II FE z "z„ Nz Il c a `" M,'' o N�o-,b ❑ ❑ ❑ ❑ 1 t „€ iPs c, ,, ";i ■ a1N WIRING BOX iirtil ,� k'" l [ 1aor., TINRhalMand mE" ,, Ci U� ■`a 4 UE o lI€i [ -. A m , `a , t, �.o Inverter is marked with one of the Q 1 CoN.aaC�RCee Q twoThis certification marks shown here(TuV or CSA). ��u 'Remote control function not available on-A version i i ai 3 3 5 ,� s r, '' 'ev 1-7 li € , t€tI ¢ '.�Vi.p 4'''..a,.' l l e x,e l a l `. E r r--=--,...4r'"-'9,,,;`nntl d [ ', a s.. ` I aeovda a € ` ', . gtla$ aav5 3 ' - ,0*. '1 4 + 3 .e€ ft. , ' , 3 3, _ [ werwwrrri 'p- wm. a[ Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US -SadtIti .' fsis„N,t E _ r 'i:[, „ti l.?[I[: ;l,`I..ta ---e- '*.. ''�9 .,n .... Enclosure rating NEMA 4X ...........................................................................................................................................:................................................................................................................................................................................................................ Coolin........................................................................................................................i..................................................................................Natural convection ......................................................................................................... Dimensions H x W x D 33.8.x 12.8 x 87in(859 x 325 x 222mm)_................................._.................... Weight........... .. <47 31b(21.3ks1 Shipping weight ......... <60Ib 27.ok ( g) Mounting system Wall bracket Bottom:(2)pre-drilled opening for�inch conduits and concentric markings for 1 inch (both sides)and 11/2 inch conduit(DC side only) Conduit connections' Sides:(2)pre-drilled opening for a/a inch conduits with concentric markings for 1 inch (both sides)and 11/2 inch conduit(DC side only) Back:(2)concentric markings,for'/_inch and 1 inch conduits DC switch ratin g(per contact)(NV) 25/600 'y mitt ompttertoe.:.,,€.. ,[IEi41-1--------14;1- „'. E ,I i,1,1, , „I.. ' Isolation level Transformerless(floating array) Safety and EMC standard UL1741,UL1741SA(draft),1EEE1547,IEEE1547 1,CSA C22.2 N.107.1-01,"tfr1{#3 UL ....................................................................................................................................................................._......................................IE 1699B,FCCPart 15 Class B ...................................................................................................... Safety approval +CSA,e or cTUV,+F Regional Compliance Rule 21,HECO,NEC 2014 690 11 NEC 2014 690.12 with ABB Rapid Shutdown device With DC switch,wiring box,arc fault detector and PVI-3.0-OUTD-S PVI-3 6-OUTD-S- PVI-3.8-OUTD-S-interrupter US-A US-A US-A • US-A 2.When equipped with optional DC switch and wiring box. All data Is subject to change without notice 11 ID 11 Power and productivity mg,li or Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD I ABB solar inverters 3 for a better world' t 4 Mono Multi Solutions ............. Trinamount FRAMED 60-CELL MODULE • • 4 -44 . - -4, . 4 -4, - '4, ' -4 PRODUCTS POWER RANGE ELECTRICAL DATA(STC) .. THE Tsm.000sA.180.0 I 280-305W Peak Power Watts-Prox(Wpr . 275 280 285 290 295 300 305 ,,,,,,f-1,'-11-,,, ,,,,!' Trinamount ,,. .. . . .. .. .., .• DIMENSIONS OF PV MODULEinwrifinches) 04ir3731 ,-.. °1,102:14:-=-:in-t---:`,1-4,-- ,- Maximum Power Vottage-Vreo(V) 31.4 , 31.7 31.8 32.6 32.9 ''''IF-18, '-'--.1.- 8.76 64 I r MODULE * -4. * -4.- 4 4 %A-, r ';" Open Circuit Voltage-Voc(V) 58.7 39.0 . 39.3. 39.5 39.7 39.9 40.2 ,.: 4roorwo 'PPY,T2F i, , ti..-4- -.,-.r..-,.,. 9 4,5-..-. gge):,...,,:l.---„X,,,,,,,p,,,!,,,IN,.,1,,, 0 • -11.- -4, 4,-4-• A 1 c) I I ..... _,.. 1p ,,,rton ttiK(A) ' ,,- 44, -- -s- '' L' -,;.,,.---__I_,---,---z-;_ Module Efficiency re(%) 16.8 • 17.1 17.4 17.7 , 18.0 18.3 18.6 - , . ...,....... , . STC Inad lance 1000W/e,Cell Temperature 25°C,Air Mass AM1.5. .;-*..7---'-'.-''----4---, -.,'":Er--s-0;a,.16 ' ' ,,(11-1211.4 10,14 fr. • +................................+.................4, (- - , *Meastning tolerance:13%. !1=-,m,7------'' ,C4-----,'' "g•,','' '''' ,1 1 MIL r ', ' '''111,, '6 IWA ;!....11M11,-72To,...,'S 4R.eel ,.•.... •'',.-E--.7--- €,1,,,... l' PaltAwlifiFm.'4,1,IF ••6 Vi•lib,i'., , ...-4,11,,,,, fr:fr ELECTRICAL.DATA(NOCT) lintallt litar4 'ilitiiiiikirapix;Ir.'. ' 'ed,..' I, -4, 4 4- 4, • 4,1 .1, ..i 'i - g iAL JP, e e ON()N iligtaidil'--14- ' MOK1.114--.'-;,' , :2 . . Maximum Power-1,4w(wp) 205 ' 209 212 216 220 223 227 , . ,4, . 4, -4 ,-4, 4, 4 .. 441`.:!7.7.4ix7i,%e-Vw.e t ii -;-1:1-' 7-.-7.T -,. ------) , 10A-.i.'- -,-:iirv41 orPo- -- m .....,--5 .,%Ap',-p'.1*izoo: .:1i" . =-' ",i.4,f,f77-- --":',---10-- --:].- 4----- iffiiiiiir idimmilk ;igr,m---±r';r•kn,•o,.-A't 'i-7."- -•t•*:.-- , • ...... qtv:P.,:omiks,,, ,,,,t--- P.Pi', 't-ft-=,-----;--:-iY:'or•r insulting Hole Maximum Power Current-1mm(A) .- 7.02 7.10 7.17 : 7.23. 7.28 7.35 7.42 o.o.-oa-o.------.;wmax•o .ftwitPT,o -0043 Ovum:1160We t--;:oo--..n eo-vo.o.:v„,0k.,. 'A:, iiMoir,3 ,---o*.o,;'1,ip 1"': ;0*.pooP,IO,4.i-o-7:=-Poo-7,-;opo, -Tii.P -•.' i1' - - ERiriiiiiititiiiiiiik'4,i,,:11,, ,,','41VAIIIIIIM -. .... \. Short CircuitCurrent-Ist(A) 7.48 7.55 i 7.63 7.67 _ 7.71 7.78 , 7.84 a liANltrerriV.L' .,111Mitat NOT in dianceal 0 W/n'Ambient temperature 20'C Wins!Spec!ho/s. .. ' - 11„;:fifiti' "..',i-,..re ,-il-, .•.i'=,,==lilifitijO -, 'i'liiiii))-Zilliiiiiiiiif.; Maximize limited space with top-end efficiency 4 , . , , __ ____ frmAil if.i.---,,,*,,,, to doL.,47e77771 oo.o 10,1771.1717.. .--Aiiii-" 40/157 492/39.1 MECHANICAL DATA Viafilila,d •Up to 186 W/m2 power density 01',404,tr•lassisve. '.3,hhilteriatik,` ' • ,i Bank View ilifil"%0' , ''13.•k',illD'' 1,,,,i.,)tit•05f.,,141,. ,i',.1 solowt ,,,' Low thermal coefficients for greater energy production at high „. ,.„,.. • Solar Cells MOnOcrystalline 156.750 156.75 mm(6 inches) 'ioni;p2T-- ilif„• ' •',.-.:----7,-.1.. operating temperatures , gg:;-.-s5-,','W--- r-, 7.-- -!:4,,4 .,------o*--.3,.. ,-,:mo ,o_ ...owiropoo!ouPo•,,,,,or.,•,-,p000.-Pot Lltit 4r,rotri24-ioo '000tooto-,--oom-:. . o•-'. ; ',., pm., o,p p•to.,...--___,pp in.,....-„, if,. Cell tr.v,-,14..---P•Po=7 P,...4.4,:l.q.,...f. ox moop-----4.. 1 o,;: ..„, •,.,,, n.7-,P 15.ft Tflomifr, ,,-''F,:.-' 4ii-f-c-2-7-',, -- Module Dimensions 1650 x 992 x 40 mm(65.0 x 39.1 x 1.57 inches) 7777747771',.., 1.plink. . ...„..o.wo.,• .:. .., , -.„Fo.--t. -,to...cop-p..4- .,..,--wo.. o; ,,,,,,,,----...-:;:f,iew.,-,: i_..„--,,,-,- _:3-ys- 1/0A3 4,9*-„N:,' , 4,,,,, : 14.6/911,A11,0 5MilirOrt' ' ' 1041141040f, ,:1"411Plifill Highly reliable due to stringent quality control laff‘t+On) ./, ,,.. , ......., -...... ,46,.... z.. 121:.4:1- ... Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass ' - -,,.,„', ----.:--17.:- '' ,:ty 9 A -Over 30 in-house tests(UV,TC,HE,arid many more) i - POWEA---0.14A.J.110 CE , ,, .,_= , ,,,- •In-house testing goes well beyond certification requirements rP, ,..:;,....4.. et ' White--- ---- vii.,..wa„,,,,' 1 •PID resistant '' Frame Black Anodized Aluminium Alloy .100%EL double inspection :3* L.] --7:-7::--,--T. tialtil oultlipoilp ,,si '-0 o,o'feope-----------------, P65-I ,• ,to.v...,... ....,,. Founded'o199/,Trine Solar is the worlds leading comprehensive solutions provider for solar energy.we , 35/138 Cables Photovoltaic Technology Cable 4.0mm'(0.006 inches'), believe close cooperation with OM partners is critical to success.Trine Solar now distributes its PV products ,.. ,,:i4-i:?'-', Certified to withstand the most challenging (A-A) l000 rnm(39.4 inches) to over(a countries ail over the wodd Trine is able to -...S ° ; environmental conditions , , ..:1„zt.,-,..;t„. , , • _ provide exceptional service to eadn customer in each is/os RVES OF IN MODULE(305W) market and supplement our innovative,reliable •2400 Pa wind load Cr4119: - ,, CqtrectOrr.,muiv*, .-.J,,,!-L--- -,--,--Aff%-:,, rodFire Type UL 1703 Type?for Solar City pucts withe backg f Tri th inone as a strong, imair,e),. •5400 Pa snow load .,„, bankable partner.We am committed to building strategic,mutually beneficial collaboration with •35 mm hail stones at 97 km/h . ..;ii,,,,,, g TO installers,developers,distnbutors and other partners, i 5.0 At-- 1.o s,\\ TEMPERATURE RATINGS MAXIMUM RATINGS .. ............, ..s.. '', \' Comprehensive Products ---'y\ NOCTeloeivatop.raiiiocrormiximuiei 44°C(12°C) Operational Temperature ! 40-'+85°C And System Certificates # _ 10 30 40 So Voalag0M .,,, 0.1,:,ature Coeffis..leritnfPsros .,(!.39lbri:,_-43,, ,,',,,,,, ,„,_,....1,1,..m 0 t4r,w,-,-, ,,,Us,it;::-----7, IEC61215/1EC61730/UL1703/1EC61701/1EC67716 ..`,. - ISO 9001:Quality Management System P-ii CIJRVES OF PV MODULE(305W) Temperature Coefficient of Voc ; -0.2996PC ., 15014001 Environmental Management System iiwp"---erature Coefficient of 14'.-v.-..--‘96/°C '..,---Z7,!' Max Series Fuse Rating ISA 100z ,,.,,,,, ,„ ..------- .----r,V.-... ,vd riii%.-iiviliri ,,-- ,-----1-55.: 15014064:Greenhouse gases Emissions Verification ow OliSAS 18001:Occupation Health and Safety 250 , /00900 o,,rv,rci risen Combiner orwith Iwo osmere at grin Management System LINEAR PERFORMANCE WARRANTY .:, - Ar.)0.,_," -- - - . ------ - . I...:, IC Year Product Warranty-25 Year Linear Power Warranty a WARRANTY PACKAGING CONFIGURATION (( :J..._ • ..- 2C.gfie 5 . 10 year Product Workmanship Warranty Modules per box:30 pieces d, . -- • iso '' .... 0 - ,, -.--7 55. osn rri,,, . N 30 44, SO Vottageen ''2;4;*'° ;' :"'')An'antY,'1''',1t7-,':;111t°45 - 1'4441°'per 46*OPer'840Pkal MK ' i 8°96 ` Years 5 10 15 20 25 CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trinasolar TcalineaWaSty Standd SMp Wanty .i'' o 2017 Irina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Trginasolar Version number:TSM_EN_2017A www.trinasolar.com , n rir rraararr ci4-1.)rt. tr' ' ,,iialtalet.i ...