Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (68)
PROJECT NOTES: SYSTEM INFORMATION TABLE OF CONTENTS 1. 9.. 70 KYW DC,7.095 KW AC SOLAR TPHOTOVOLTAIC SYSTEM MAGNETIC TRUE 3. CONSTRUCTION CO47p. P SHINGLE ROOF O FI PITCH. ARRAY PITCH O S S C 3111 PAGE DESCRIPTION 3. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT RUN PLACEMENT ORIENTATION ORIENTATION # WITH CUSTOMER. AR-01 17° 145° 130° PV-01 SITE PLAN&MECHANICAL 4. CONTACT:D.JANOSEC 5. DESIGN CRITERIA: 5.1. SYSTEM WEIGHT:3LBS(SOFT. TOTAL PV ARRAY AREA: 605 FT' PV-02 RACKING LAYOUT 5.2. EFFECTIVE WIND SPEED:95 MPH 3-SEC GUST. LARGEST PV SECTION: 36.6 FT PV-03 RACKING DETAIL 5.3. WIND EXPOSURE CATEGORY:B ROOF SLOPE: 17° 5.4. SNOWLOAD:25 PSF 5.5. OCCUPANCY CATEGORY:II ROOF AREA MEASURED IN PLAN VIEW: 1982FT2, PV-04 SINGLE LINE DIAGRAM PV ARRAY/ROOF AREA: 30.52 % OFFPY PROPERTY LINE PLAN-SCALE: 3/64"=1'0" SITE PLAN -SCALE: 3/64"= 1'0" ,. 'i,4 h, .4 4 k..r� .e � V f 2017 (E} MAIN PANEL ,Il c 'Yk / (INTERIOR WALL) (E)VENT S p< - v / ' i 1 i 1 II 0 PZ S� (N) ROOFTOP co JUNCTION BOXES # (N)SOLAR ARRAY AR-01 .,` . ''" 6;7' SOUTH-WEST FACING ELEVATION -SCALE: 1/8"= 1'-0" tP / 8$ / . _____ _ _ A� Qv f (E)SERVICE ENTRANCE OFFICE COPY 15L • & UTILITY METER • (EXTERIOR WALL) c o� j is FOR CODE COMPLIANCE Approved: ] OTCs I I } Permit#: r»S-f-an 17 - O Q , 4, Address: tx-ix c c kA, n c k In; H l.17 INDICATES TSRF PERCENTAGE Suite#: ELECTRICAL EQUIPMENT LOCATIONS NTS By: —V Date: 6- 13 _)' ELEMENTAL ji\1 NEk( M7 < r� CHECKED BY D.JANOSEC OR CCB#: 1 514 RGY 15750 SW OAKHILL LANE, TIGARD,OR 97224 SMETE CHANICAL& PV-01 REV:A 5/25/2017 RACKING&ATTACHMENT LAYOUT-SCALE: 3/16"=1'-0": ' IN-PLANE VIEW AR-01 - ALLOWABLE RAIL LOCATIONS HYUNDAI HIS-S29ORG typ.40"x 65"(Including Clamp Spacing) s 3 I 16" , ! __.� _. _ r ._.__ }.___ _�. y 1 +._j) --',"__ 6 I I 1 I i I. I i 1 1 I ! i 3'-6" LANDSCAPE I i TYP. I i , , I Fn. I L — C17 '' -- - -= -- -;—� 1 --RJ_ ____ goy /�i �U// i�,� � 10r, I1 D ,i ,- ,,:) __. ! F- i I ; 1 I i I I , I kb, I --0 --I ---, 'I —SI 4 ---] ///7,egrff ./// O 25-0" 9 l i { I >I. 4 11 ----EP 01 ---4 —411 ----H I I I ) - -4 1 MATERIALS NOTES TO INSALLER: < -a 0 ---1 i � I I1 (63)MOUNTING ASSEMBLIES 1 ; 1 (12) END CLAMPS I ! I I j (60)MID CLAMPS + I 1 ° �� l i _ (1)SOLADECKS O I _ _._.�_ 1 _I i__ 't______ L i _° 132" RAILS ° 168" RAILS Z ( j E " 1 1 5.-2" 204" RAILS SPLICES 4-0 2-0 (. ) MAX. TYP. STRUCTURAL DETAILS-SCALE:3/16"= 1'-0": Et _---- -- �"-~ \ 1 8"MAX HEIGHT OF DRAWING KEY: "� __ MODULES (TYP.)6" 25'-0" — _- 1 :::ETBACK 12"ROOF VENT .I JUNCTION BOX , ,= '. ~ (1'TYP) 1 -- SOLADECK 11r FIRE SETBACK(3'TYP) ENPHASE M215 MICROINVERTER RAFTER ENPHASE M215 TRUNK CABLE \----- 2x4 MANUFACTURED TRUSSES Ironridge XR-10 Rail THHN IN CONDUIT 24"O.C. -Ar- (SEE WIRING SCHEDULE ON PV-03 FOR SIZING) 0 Ironridge Mount&Flashing i"0 X 3" LAG SCREW __. h �El\ITA: -r E i' t+l1 CHECKED BY D. JANOSEC OR CCB#A19514 1 LARRY BYERS RGY 15750 SW OAKHILL LANE, TIGARD,OR 97224 LAYOUT PV-02 5/25/2017 I . 1 . RACKING DETAILS .. 1 <.. GI II sI 11 II Q q ss 61 41— rjl ioilillillIll*s CARIES co O SIDE VIEW, FLUSH MOUNT ON PITCHED ROOF Scale:1"=1'-0" 0 0 E4C �Q 11 (f AS REQLIRED BY MODULE MAN,UFACTURER ` I ( 0 I I I PV MODULE Jr © IRONRIDGE RAIL cii.„ ( I ,Z t I P4 04 O PLAN VIEW, FLUSH MOUNT ON PITCHED ROOF O FRONT VIEW, FLUSH MOUNT ON PITCHED ROOF Scale:1"=1,0" Scale P'=1'-0" PV MODULE, BY OTHERS 7 IRONRIDGE IRONRIDGE RAIL RAIL IRONRIDGE IG MID CLAMP IRONRIDGE END CLAMP (E) ROOF — PV MODULE FRAME PV MODULE FRAME PV MODULE FRAME PV MODULE FRAME Jam`'-- A MEMBRANE IRONRIDGE IG MID CLAMPS -, IRONRIDGE END CLAMP m � IRONRIDGE RAIL �r IRONRIDGE RAIL 0.2500- n-- iRONRIDGE @ Ip � '; FLASHFOOT -� �__` 41 I ASSEMBLY 411111111101111 (E) BUILDING --2 ______- STRUCTURE OSTANDOFF DETAIL „ O DETAIL, MID CLAMP PLAN O DETAIL, MID CLAMP FRONT �J DETAIL, END CLAMP PLAN O DETAIL, END CLAMP FRONT D Seale:3"=1-0" 1 s X 3 LAG SCREW E Scale:6"=1,-0" kale:6"=1-0" Scale:6"=1,0" - E . L IVALrilL d\_k ,,, Y CHECKED BY D. JANOSEC OR CCB#: 195141ENERGY 15750 SW OAKHILL LANE, TIGARD, OR 97224 DETAILS PV-03 5/25/2017 RAM: VOLTAGE DROP CALCULATIONS ,74-14 120/240 VAC SINGLE PHASE SERVICE MODULES TO COMBINER: VOLTAGE DROP FOR 240 VAC, 4 WIRE, 1.0M PORTRAIT PORTLAND GENERAL ELECTRIC ENGAGE CABLES AND M215s, END FED(FROM SPEC. — METER#: 0002-55291-416248-6 SHEET) IS 0.35%. 'Y D .r COMBINER TO MAIN PANEL,40 ft. MAX: EXISTING %VD=(2 x 40 ft x 29.7 A x .809 0/1000 ft.)/240 V=0.80% 150A MAIN V.D. =0.35% +0.80% = 1.15% BREAKER '. ENPHASE: M215 EXISTING SOME PAIRS MICROINVWFLIR — 200A MAIN NOT SHOWN PV MODULES —^— PANEL (N) SOLADECK — FOR CLARITY _— SJUNCTION BOX ./� s 1 / HYUNDAI: HIS-S29ORG —3 2 (, +O'2 (33) MODULE/INVERTER PAIRS 2 ti — (3) BRANCHES OF(11) MODULES INVERTER OUTPUTS CONNECT ENPHASE ----- E '' ,.. CABLE -GEC TO AUX GND CONNECTED TO OUTPUT CABLE TO 7,,',D TRUNK #6 THHN 4 PV BREAKER 20A BREAKER ON EACH ENGAGE CABLE ENGAGE CABLE O TION KIT 1 'POSITE SIDE OF BRANCH. NO BREAKERS ON SBAR INSTALLS W/ <17 MODULES. llr ..:;.ii. _ f IIT SCHEDULE LABELLING REQUIREMENTS: WARNING:PHOTOVOLTAIC POWER SOURCE CONDUIT CONDUCTOR NEUTRAL EGC r- LOCATED AT UTILITY METER OUTSIDE&INSIDE PANEL 4. NONE (2) 10 AWG PV WIRE NONE N/A CODE SECTION: NEC 690.64.8.4 PHOTOVOLrmc AcDLSCONNECT NONE ENPHASE ENGAGE CABLE ENPHASE ENGAGE CABLE ENPHASE ENGAGE CA LE MAXIMUM AC OPERATING CURRENT: Mall /4" EMT OR EQUIV. IF EXT; (2) 8 AWG: THHN/THWN-2 IN (1)8 AWG:THHN/THWN-2 IN NOMINAL OPERATING AC VOLTAGE NONE IF INTERIOR CONDUIT OR NM-B IF NO CONDUIT CONDUIT OR NM-B IF NO CONDUIT (1) 10 AWG THHN/THWN-2 LOCATION:ON AC DISCONNECT(IF INSTALLED,WHEN AC INVERTER OUTPUT IS GREATER THAN 30A PER UTILITY NET rt ' METERING REQUIREMENT AND CODE). fi CODE SECTION: NEC 690.14.C.2&NEC 690.54 NOMINAL OPERATING AC VOLTAGE: IIIIIIIIIIIII_ NOMINAL OPERATING AC FREQUENCY: )F INTERCONNECTION: MODULE CHARACTERISTICS S EM CHARACTERISTICS MAXIMUM AC POWER. 1111111111111111 ED BREAKER ON MAIN PANEL !NUMMI AC CURRENT. 11101111111111111111 40 AMP PV BREAKER TO MAIN PANEL HYUNDAI: HiS-S29ORG 290 W NOMINAL OPERATING AC VOLTAGE 240 V MAX OVERCURRENTDEVICE RATING Fop.ACMODULE PRGTECTaN. PANEL RATING:200 A OPEN CIRCUIT VOLTAGE 38.8 V PANEL MAIN BREAKER RATING: 150 A NOMINAL OPERATING AC FREQUENCY 60 HZ LOCATION:AT POINT OF INTERCONNECTION CODE OPEN CIRCUIT VOLTAGE: (690.7) 42.4 V SECTION: NEC 690.53 ICAL NOTES: I MAC POWER 7095 W IOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. MAX POWER VOLTAGE 32 V SOLAR ELECTRIC TEDINIM :TRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. b!IAXIMiJM AC CURRENT 29.56 A DISCONNPCrLOCATEDINMAIN SHORT CIRCUIT CURRENT 9.7 A SERVICE PANEL ULES CONFORM TO AND ARE LISTED UNDER UL 1703. MAXI OVERCURRENT DEVICE RTER CONFORMS TO AND IS LISTED UNDER UL 1741. SHORT CIRCUIT CURRENT(690.8(A)(1)) 12.13 A RATIN FOR AC MODULE PROTECTION 40 A LOCATION: NEAR UTILITY METER,ON UTILITY WDC CONDUCTORS ARE SIZED FOR DERATED CURRENT. METER OR SOLAR PRODUCTION METER MPS MODULE SHORT CIRCUIT CURRENT. -' 3�%,0,� '' s' "' r F5 c AMPS DERATED SHORT CIRCUIT CIRCUIT(690.8(a)&690.8(b)). '^ z `6`''M F "'.i"w. .'a de'r.`; ir+r 4N'X,r '41"v: TO INSTALLER: LOCATION: NEXT TO SOLAR BREAKER INSIDE TY CONDUCTORS TO LOAD SIDE, BOTTOM ELECTRIC PANEL ONDUCTORS TO LINE SIDE,TOP C VOLTAGE DROP MAXIMUM AT 2% RESPECTIVELY " ) '- . � `fr ) :::; ' DESIGNED BY: C. BOYCE ELEMENTAL ENERGY LARRY BIERS �� � _ LNL - p CHECKED BY: D.JANOSEC OR CCB#: 195141 15750 SW OAKHILL LANE, TIGARD,OR 97224 DIAGRAM LINE PV-04 5/25/2017