Plans (69)
o eao SCOPE OF WORK FIRE EQUIPMENT SYMBOL LIST SESES! INSTALL A NEW ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM WHICH SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT m O INCLUDES CENTRAL STATION OFF-SITE REPORTING, SPRINKLER FLOW ANDNOTo ts IFIER o TAMPER VALVE MONITORING, MANUAL PULL STATIONS, SMOKE DETECTORS, HEAT FACP FIRE ALARM CONTROL PANEL NFW2-100 SELF-CONTAINED SURFACE MOUNT 54" TO TOP OF HIGHEST DETECTORS, ELEVATOR CONTROLS, AND HORN/STROBES. REV 3 19"H X 16.65"W X 5.20"D USER FUNCTION AFF 'v o Ea FIRE ALARM CELLULAR COMMUNICATOR DSC SURFACE MOUNT ALIGN WITH OTHER EQUIPMENT ., r 7 3G4010CF 10"H X 11.5"W X 3"D El....13 2Q1 r n SEMI-FLUSH MOUNT �j`, REMOTE FIRE ALARM ANNUNCIATOR NOTIFIER 1-GANG, 2-GANG, OR 54" TO TOP OF HIGHEST L j�Tlil N-ANN-80 4"SQUARE USER FUNCTION AFF CI nO''F T31\1410.41.4110 1IG`+ WF SPRINKLER FLOW SWITCH (BY OTHERS) BY OTHERS MONITORED BY NMM-100P �UIL�IiVG J�V I '� GENERAL NOTES 0 SPRINKLER TAMPER VALVE (BY OTHERS) BY OTHERS MONITORED BY NMM-100P a 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 70, ARTICLE 760, POWER UMITED SYSTEMS. ® ADDRESSABLE MINI MONITOR MODULE NOTIFIER MOUNTS INSIDE 1-GANG MOUNTS INSIDE 1-GANG 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE NMM-100P THAN ONE FLOOR SHALL BE RISER RATED. 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 0 ADDRESSABLE RELAY MODULE NOTIFIER 4"SQUARE ALIGN WITH OTHER EQUIPMENT 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. ® NC-100R 41461 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTNING PROTECTION DEVICES. NOTIFIER 1-GANG, 2-GANG, OR 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY ❑F MANUAL PULL STATION - ADDRESSABLE NOT-BG12LX 4"SQUARE 46" TO CENTER AFF PROTECTED. 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS NOTIFIERC "FIRE ALARM CIRCUIT". % PHOTOELECTRIC SMOKE DETECTOR NP-100 4" OCT OR SINGLE GANG CEILING MOUNT v 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE (NEPA 72). NOTIFIER0 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION <4 FIXED TEMPERATURE HEAT DETECTOR NH-100 4" OCT OR SINGLE GANG CEILING MOUNT OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR C.g CEILING MOUNT HORN/STROBE - RED SYSTEM SENSOR 4" SQUARE, 4" OCT, OR DOUBLE AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH Ir",I (NAC AND CANDELA NOTED AT DEVICE) PC2RL GANG BACK BOX CEILING MOUNT Q SECTION 14.6.2.4 (NFPA 72). 11. A LOCKABLE DOCUMENT STORAGE CAN SHALL BE PROVIDED. GENTEX GENTEX GBBB WEATHER PROOF I 24 VOLT WATER FLOW BELL GB6-24 BACK BOX 96" AFF p DOCUMENT ENCLOSURE WITH INTERNAL SPACE AGE54" TO TOP OF HIGHEST CO DOC FLASH STORAGE SS000685 12"W X 13"H X 2-1/4"0 USER FUNCTION AFF I C rg WC Ili H SITE H CO TELEDATA W SW DARTMOUTH STREET SYMBOL DESCRIPTION W I I i''' ` 1 ---4111r-11 I��_.__.-7 1 era 11; PHONE JACK I I L 'mIt =� BUILDING A � I 1 Z �N/ „� W LL / > ch , .. 1 ......... � iii d ASA ° b �? - � AREA OF WORK CITY._ . . _. 1 ! . OF TIGARD ►..,. �� ( _ bit W REVIEWED FOR CO COMPLIANCE 0 u) d W . ' :3 - -1 BUILDING C— FLOOR 2 Q k r /���� Q 4 4 4 i q ��, Approved: ._ w p- LJ- 1 s ji I OTCs i �� ����� �� ���� REVIEWED/APPROVED: a I BUILDING C j .vI 1 j.��(/��A2*2-C) /ii/ (ZV 5..... ,.. .... .44i= - Via. J j L/7 /7/ /7 -,/ �� .41 __s 1 j/ �� j BEN BREIT-4460LEA E3 ^ Sulfite , ' - /jj AREA of WORK j DO REV./DATE D _ i / 8/02/17 j >iI , 0 111••••III. 7y 1l`i' `,1 i.I 11 1 BUILDING C — FLOOR , `•/t�\T'•� b 9 1";:.....40,111 i 1 �I 1 1 DRAWN BY: ►4J OFFICE COPY NGM - ii, b q rrr I �ti® — — - - ---— CHECKED BY BJB AREA OF WORK FILE FNAME ELMHURST ST. DEDICATION i �, A.dwg 74114;0 Milr NOT TO SCALE DRAWING#: FA-1 ORIG.SHEET SIZE:11"x 17" #OF DINGS IN SET: SHEET 1 OF 5 BATTERY CALCULATIONS NOTIFICATION CIRCUIT SCHEDULE rkW' NOTIFIER NFW2-100 REV 3 (ELEC RM) VOLTAGE DROP CALCULATIONS Woo PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT L CKT DEVICE LOCATION / AREA ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP X W NFW2-100 MAIN CIRCUIT BOARD 1 0.1450 0.1450 0.2750 0.2750 N-ANN-80 REMOTE ANNUNCIATOR 1 0.0150 0.0150 0.0400 0.0400 N-1 HORN/STROBE FLR1, HALL 108, LOBBY 100 FACP 0.217 130 14 0.17 20.23 YES 0.85% NOT-BG12LX PULL STATION ADDR 1 0.0004 0.0004 0.0005 0.0005 N-2 HORN/STROBE FLR2, LOBBY 200 FACP 0.071 140 14 0.06 20.34 YES 0.30X N-3 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% NP-100 PHOTOELECT ADDR HEAD 5 0.0003 0.0015 0.0065 0.0325 z NH-100 HEAT DETECTOR HEAD 2 0.0003 0.0006 0.0065 0.0130 N-4 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% a NMM-100P MINI MONITOR MODULE 5 0.0004 0.0020 0.0050 0.0250 *****END-OF-LINE METHOD OF CALCULATION NC-100R RELAY MODULE 4 0.0003 0.0012 0.0065 0.0260 GB6-24 6' WATERFLOW BELL 1 0.0000 0.0000 0.1000 0.1000 `. PC2RL HORN/STROBE - 15 CD 1 0.0000 0.0000 0.0710 0.0710 PC2RL HORN/STROBE - 150 CD 1 0.0000 0.0000 0.2170 0.21701 A it N-3 SPARE NAC 1 0.0000 0.0000 0.0000 0.0000 N-4 SPARE NAC 1 0.0000 0.0000 0.0000 0.0000 STANDBY TOTAL 0.1657 ALARM TOTAL 0.8000 *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* AMPS (A) X TIME (H) = AMP-HRS (AH) 20X DERATE STANDBY 0.1657 X 24 = 3.9768 - ALARM 0.8000 X 0.0833 = 0.0667 - TOTAL AH = 4.0435 4.8522 BATTERIES TO BE INSTALLED: 7.0 All Co) 0 Z 0 FIRE ALARM OPERATIONAL MATRIX J - SYSTEM OUTPUTS mM 4Q�� ��� W P`' e 00 Nt �•,P 5 W I'm V J V- a- 0 OY�e � � { : 4/`<g". 0' .P.y W CO �Pd ,c‘ � � ° ° ,P�,PP� ° J40 �`u 4 � P QOp S SC SYSTEM INPUTS N,-09-• (3) oN) q �q P°�P°�P°� 00c c, ,S,S,,,4, Es: w P` PULL STATION • • • • N SMOKE DETECTOR - NON ELEVATOR • • • • 0 i H rn SPRINKLER FLOW SWITCH • • • • • rL P O SPRINKLER TAMPER SWITCH • • 0 COMM TROUBLE • • to Ct 07 0 W W ¢ _ LOSS OF AC POWER AT FACP • • � I.L OPEN CIRCUIT • • DWG REV./DATE DISCONNECTION OF BATTERIES • • 0 08/02/17 GROUND FAULT • • SMOKE DET. - ELEVATOR LOBBY MAIN FLOOR • • • • • DRAWN BY: SMOKE DET. - ELEVATOR LOBBY OTHER FLOORS • • • • • NGM SMOKE DET. - ELEV MACH RM/TOP OF SHAFT • • • • • • CHECKED BY: HEAT DET. - ELEV MACH RM/PIT/TOP OF SHAFT • • • • • • BJB FILE NAME - SHUNT VOLTAGE MONITOR • • FA.dwg DRAWING it PRESS SIGNAL SILENCE KEY • • PRESS RESET KEY • FA-2 ORIG.SHEET SIZE:115c I r S OF DWGS IN SET: SHEET 2 OF 5 DETECTOR SCHEDULE MODULE SCHEDULE FIRE ALARM RISER DIAGRAM 8"$ �S ADDRESS DEVICE LOCATION / AREA ADDRESS DEVICE LOCATION / AREA co° 0060g D-1 PHOTO FLR1, ELECTRICAL ROOM 106 - AT FACP M-1 SPARE SPARE SLC (TYPICAL) L-' D-2 SPARE SPARE M-2 MONITOR FLR1, ELECTRICAL ROOM - COMM TROUBLE Si a D-3 SPARE SPARE M-3 FLOW FLR1, MECH/SPRKLR RM 105 - WET FLOW AT RISER W D-4 SPARE SPARE M-4 TAMPER FLR1, MECH/SPRKLR RM 105 - WET TAMPER AT RISER c LH 0. 0 . ., .. D-5 SPARE SPARE M-5 TAMPER FLR1, IN VAULT - DBL CHK VALVE __ D-6 SPARE SPARE M-6 SPARE SPARE D-7 SPARE SPARE M-7 SPARE SPARE TYPICAL PWR ( WF ) BY OTHERS ` D-8 SPARE SPARE M-8 PULL FLR1, LOBBY 100 - PULL AT MAIN ENTRY SLC TO FACP 14/2C FPLR — D-9 PHOTO FLR1, AT ELEVATOR LOBBY M-9 SPARE SPARE 18/2C FPLR / J 0 8 i D-10 PHOTO FLR1, AT ELEVATOR CONTROLS M-10 SPARE SPARE D-11 HEAT FLR1, AT ELEVATOR CONTROLS M-11 SPARE SPARE bbb D-12 SPARE SPARE M-12 RELAY FLR 1, ELEVATOR RECALL TO MAIN FACP AND NACS (TYPICAL) Alit D-13 SPARE SPARE M-13 RELAY FLR 1, ELEVATOR RECALL TO ALT LECTRIC ROOM 106 D-15 SPARE SPARE M-15a D-14 SPARE SPARE M-14 RELAY FLR 1, ELEVATOR HAT FLASH Y FLR 1. ELEVATOR SHUNT TRIP D-16 SPARE SPARE M-16 MONIITTOR FLR 1 ELEVATOR SHUNT VOLTAGE \..._ AUX 24VDC 1 I C ••, EOL'4.7k0 D-17 SPARE SPARE M-17 SPARE SPARE c • I SLC I C4Ve NOTIFIER 2 Io ZZEOL_4.7k0 D-18 SPARE SPARE M-18 SPARE SPARE NFW2-100 e D-19 SPARE SPARE M-19 SPARE SPARE RJ REV 3 3 SPARE IEOL IR4.7k0 D-20 SPARE SPARE M-20 SPARE SPARE ® R.. -1— RJ lFACP WAIEOL 1_4.7k0 D-21 PHOTO FLR2, AT ELEVATOR LOBBY M-21 SPARE SPARE I DACT 4 I SPARE 4�e D-22 FLR2, AT TOP OF ELEVATOR SHAFT M-22 SPARE SPARE D-23 PHOTOHEATFLR2, AT TOP OF ELEVATOR SHAFT M-23 SPARE SPARE / I 120VAC DEDICATED D-24 SPARE SPARE M-24 SPARE SPARE I— D-25 SPARE SPARE M-25 SPARE SPARE 18/4C (6)D-26 SPARE SPARE M-26 SPARE SPARE r ***SPARE CONTINUES*** ***SPARE CONTINUES*** v D-99 SPARE ISPARE M-99 I SPARE ISPARE REMOTE ANNUNCIATOR (TYPICAL) Z r FLR 1 LOBBY 100 1 0 I I J I NOTIFIER I * ` I N-ANN-80 I /� FAA I W TO/FROM FACP L --I Q\-- 18/4C CC w SLC TO FACP W H 18/2C FPLR I- ' ) ELEVATOR CONTROLS (TYPICAL) W 'vim/, r -T r ELEVATOR EQUIPMENT CLOSET 1 V U) TOP OF SHAFT 4 W 2 1 / C2 RECALL TO MAIN TO �/ Z Gt OTHER LOBBIES Z RECALL TO ALT ELEVATOR i M �I,HAT FLASH GUTTERUT � 0 2 ti MAIN LOBBY (% ,SHUNT TRIP CABINET re P x Q `P SHUNT VOLTAGE PAM SHUNT TRIP > 0 El 0 ©. 0 WN Lo w 1:tELEVATOR PIT L�f� c EL18/2C FPLR L J L J i? * INSTALLED IF NEEDED DWG REV./DATE 0 08/02/17 NOTE: WIRE TO BE FPL, FPLR OR FPLP PER NEC DRAWN BY: NGM CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#. FA-3 ORIG.SHEET SIZE.11"x 17" B OF DWGS IN SET: SHEET 3 OF 5 0 0 0 8 O O 10 g10 N J O moo W " - r 7 W" I yQw i IIIIIP ---1 __l _J1--_ FAC 11 _ , 7 -, -- O) O F M-8 I 1 I T I I I I li 1 d" ♦♦�♦♦ dNI I I + , _ I I I I I I _ I VERIFY LOCATION �/ ooz loon DBL CHK VALVEi Illit •4(O3BY♦' IN VAULT E111111111 , 0 6, 4.10.<\_4#7, 0 ON _ _ N .•. N l— I — — d d �� VERIFY LOCATION 04 II ELEVATOR CONTROLS ELECTRICAL ROOM D-9 RECALL MAIN €30.M-12 RECALL ALT 4 M-13 `--P 106 HAT FLASH 0®M-14 • C /%11.4).M t I"' ELEVAT0R SHUNT TRIP0®M-15 1 1 FACP ♦^ I. SHUNT VOLT ®M-16 V UP HALO — D-10 D-11 q 108 IwErSYSTEM MECH/SPRINKLER RISER ROOM 0 (N) WF J _ 1 Ts 105 I . C M STAIR EOL -\ JANITOR CO 150C) NI (N) 102 2 r! CO-- - --1E1 Ct w III Im. E 1 I— (I) z >- 10. STAIR w CO 3 V LIJ E CC 1 V rte¢ N = I— CD o � O 0 () p W W � � � I I I 0 re '71LL — --@) DWG REV./DATE 16, [`\�n//J\ 0 08/02/17 DRAWN BY: 1 1 1 1NGM CHECKED BY: BJB FILE NAME: / FA.dwg • ,% kt 0 4' 8' 16' DRAWING#: J FLOOR 1_ 1 FA-4 SCALE: 1/8 ——1 0 ORIG.SHEET SIZE:11'k 17" #OF DWGS IN SET: SHEET 4 OF 5 000 lion m� POl° mOo y O Li Il 14 1 A iiii 5 6 r I ; 1 II U 11 —HI 1 O CIRCULATION 459 NET SF 0 �" _ z (J) I I N J ' ''(..--1 ;.--;' Y ELEVATOR D-22 D-23 c G <4 <4 IX W UP TOP OF S-AFT {WJ �I— EOL \ ■ v J 15CD c Z W (n 7 V u STAIR LOBBY w z 1 200 w N) FROM FACP N zoos ON FLR1 0 I- 0) 0 1 C/ P o Q p () o W W � a �_ O DWG REV./DATE 0 08/02/17 FLOOR 2 ° 4' 8' 16' DRAWNBY: �m�� NGM % ,� SCALE: 1/8"=1,-O" CHECKED BY: BJB FILE NAME: • FA.dwg DRAWING•: FA-5 ORIG.SHEET SIZE:11"x 17' *OF DINGS IN SET: SHEET 5 OF 5