Loading...
Permit (129)f CITY OF TIGARD MASTER PERMIT Ill . COMMUNITY DEVELOPMENT Permit#: MST2017-00226 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/23/2017 TIGARD. Parcel: 2S111DC09300 1 Jurisdiction: Tigard Site address: 15750 SW OAKHILL LN Subdivision: SUMMERFIELD NO.10 Lot: 564 Project: BYERS Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: Bedrooms: First: sf Basement: sf Left: Parking Spaces: Height: Bathrooms: Second: sf Garage: sf Front: Smoke Dwelling Units: Third: sf Right: Detectors: Total: sf Value: $0.00 Rear: PLUMBING Sinks: Water Closets: Washing Mach: Laundry Trays: Rain Drain: Urinals: Lavatories: Dishwashers: Floor Drains: Sewer Lines: SF Rain Storm Sewer: Tubs/Showers: Garbage Disp: Water Heaters: Water Lines: Drains: Catch Basins: Bckflw Prevntr: Footing Drain: Ice Maker: Hose Bib: Backwater Value: Other Fixtures: Drywell-Trench Drain: Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: Clothes Dryers: Heat Pump: N Hoods: Other Units: Furn<100K: Vents: Woodstoves: Gas Outlets: Furn>=100K: ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits j 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Roof top PV system Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 Owner: Contractor: BYERS,LARRY E ELEMENTAL ENERGY LLC Required Items and Reports(Conditions) 15750 SW OAKHILL LN 3123 SE BELMONT ST TIGARD,OR 97224 PORTLAND,OR 97214 PHONE: PHONE: 503-967-5786 FAX: Total Fees: $353.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503. 32.1987 or 1.800.332. -.4. 14 Issued By: /i1_�1L /� Permittee Signature: , (/c/L/ 'J / - 6r�3.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. /7/�y Building Permit Ap lication rivANV Residential 'Vke --° '° City of Tigard - ' On! Received 14Per9 t °' Date/By: 1.7 4477-.- mit No.: 1 f'7r--°fir`,% 7-. ) � !. 13125 SW Hal]Blvd.,Tigard,OR 97223 \ �,}. / d)r�W W/717�ViY ■ Phone: 503 718.2439 Fax: 503.598 1960 : u$ Da ePlan Review/—13—) 7 // Other Permit: _ L 'fis at Date/By: v /�lv��� eta T 1 G A R D Inspection Line. 503.639.4175 .t )n 4: e Date Read/B Juds: H See Page 2 for Internet. www.tigard-or.gov P� Ready/By: ty Notified/Method �0' (Q�/ J Supplemental Information Dgi TYPE OF. QUIRED DATA:I-AND 2-FAMILY DWELLING 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Addition/alteration/replacement ❑Other: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 21-and 2-family dwelling 0 Commercial/industrial Valuation: $ ❑Accessory building El Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 15750 SW Oakhill Ln New dwelling area: square feet City/State/ZIP: Tigard, OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:3 y C c' Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-tJSE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 7.095 kW Prescriptive Roof-Mounted Solar PV Installation Valuation: $ Existing building area: square feet New building area: square feet PROPERTY OWNER ❑ TENANT Number of stories: Name: Larry Byers Type of construction: Address: 15750 SW Oakhill Ln Occupancy p y groups: City/State/ZIP: Tigard, OR 97224 Existing: Phone:(971 )570-9957 Fax:( ) New: El APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name: Elemental Energy (Please,refer tvfee sekedure) Contact name: John Grieser Structural plan review fee(or deposit): Address: 3123 SE Belmont St FLS plan review fee(if applicable): City/State/ZIP: Portland,OR 97214 Total fees due upon application: Phone:(503 )967-5786 Fax::( ) Amount received: E-mail: john@elementalenergy.net PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top •counted PhotoVoltaic Solar Panel System. Business name: Elemental Energy, LLC Submit two )sets of roof plan with connection.: ails Address: 3123 SE Belmont St and fire depart ,ent access,along with th-. i"0 Oregon Solar Installation secialry Code c -- ist. City/State/ZIP: Portland,OR 97214 Permit Fee(in des pl,• eview and admi ative fees $180.00 Phone:(503 )967-5786 Fax:( ) )' State surcharge , %of p--, it fee): $21.60 CCB lic.: 195141 Total -- :tie upon applicat'n: $201.60 Authorized signature: This permit application expires if a permit is not obtained //1/ within 180 days after it has been accepted as complete. Print name: John Grieser Date: 5/24/2017 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPemutApp.doe 02/24/2011 440-4613T(11/02/COM/WEB) F Electrical Permit Application FOR OFFICE USE oNLY- Received Permit No.: City of Tigard Date/By: .-.1 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review /Other Permit: Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Inspection Li503.639.4175 Date Ready/By. Juns: El See Page 2 for til ARLJ p Line. No • • .. ••. r Supplemental Information In et: wwwtigard-or.gov TYPE OF WORK / PLAN REVIEW El ElPlease check. that' apply(submit 2 sets of plans w/items checked below): New construction Additi� eration/replacement ❑ Service off'ceder 400 amps or more ❑Building over three stories. 0 Demolition al Other: where e available fault current 0 Marinas and boatyards. ex -,ds 10,000 amps at 150 volts or 0 Floating buildings. TEGORY OF CONSTRUCTION e- to ground,or exceeds 14,000 0 Commercial-use agricultural El 1-and 2-family.welling si Commercial/industrial ❑Accessory building :mps for all other installations. buildings. Fire pump. 0 Installation of 150 KVA or Multi-family i aster builder El Other: larger separately derived system. '❑Emergency system. b P Y Y JOB SITE IN'$.RMATION AND LOCATION 0 Addition of new motor load of ❑"A","E","1-2","1-3", 100HP or more. occupancy Job no.: I Job site addr:,s: 15750 SW Oakh' n 0 Six or more residential units. 0 Recreational vehicle parks. 0 Health-care facilities. ❑Supply voltage for more than City/State/Z1P:Tigard, OR 97224`, ❑Hazardous locations. 600 volts nominal. Project n• e: ❑Service or feeder 600 amps or more. Suite/bldg./apt.no.: i - FEE SCHEDULE Cross street/directions to job site: Description 1 Qty. I Fee. I Total I * New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: of no.: 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: Limited energy,residential 75.00 2 ESCRIPTION OF WORK (with above sq.ft.) Limited energy,multi-family 75.00 2 7.095 kW Prescriptive -bof-Mounted Solar PV Installatit n �..------�Tile en i. e sq.ft.) -� Renewable Energy ❑ See Page 2 Services or feeders install tion,alteration,and/or relocation 0 T. ANT 200 amps or less 100.70 2 PROPERTY 0 WNER 201 amps to 400 a.: 133.56 2 Name:Larry Byers 401 ampsts.it amps 200.34 2 Address: 15750 SW Oakhill Ln 601 :. ps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP: Tigard, OR 97224 Temporary services or feeders installation,alteration,and/or _relocation Phone:(971)570-9957 ax:( ) 200 amps or less 59.36 1 Owner installation:This installation is bein,made on property that : n which's not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange, . cording to ORS 44 49,670,and 70 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits-new,alteration,or extension,per panel I!_I APPLICANT I 0 CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, 7.42 2 each branch circuit Business name: Elemental Energy Fee for branch circuits without Contact name:John Grieser ervice or feeder fee,first 56.18 2 b`nch circuit Address: 3123 SE Belmont St Each a..'I branch circuit 7.42 2 Miscella'eous(service or feeder not included) City/State/ZIP: Portland,OR s' 4 Each manu•'ctured or modular 67.84 2 dwelling,se 'ce and/or feeder Phone:(503 )967-5786 Fax::( ) Reconnect only' 67.84 2 E-mail: john@elemetal ty.net Pump or irrigatio circle 67.84 2 CONTRACTOR Sign or outline light,,g 67.84 2 Signal circuit(s)or lii 'ted-energy See Business name: Element: nergy panel,alteration,or ext: sion. Page 2 2 \ Each additional inspe ion over allowable in any of the above Address: 3123 SE BeImO�St Additional inspection(1 hr in) 66.25/hr City/State/ZIP:Portland, $R 9"-14 --- _— Investigation(1 hr thin) 66.25/hr Phone:(503 )967-5786 I Fax:( ) Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 195141 lectrical Lie.:C1228 I Suprv.Lie.: 4786S specifically listed(1/4 hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: (2 L _,,,� / Subtotal: Plan review(25%of permit fee): Print name: Charles Harry e:5/24/2017 State surcharge(12%of permit fee): Authorized signature: ://7. 5---- TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: John Grieser I Date: 5/24/2017 days after it has been accepted as complete. * Number of inspections allowed per permit. I.\Building\Permits\ELC_PermiiAPP_ELR ERE.doc Rev 05/2(/2013 440-4615T(I I/05/COM/WEB *Electrical Permit Application ._ ccIN .,,, FOR OFFICE, l SF 0\11 City of TigarAt. ,t Date/BReceivea Permit No.: 5rei - 111 • 13125 SW Hall Blvd.,Tigard,OR 9722 7 ' Plan Review Phone: 503.718.2439 Fax: 503.598.1960 t,., 1 1131 t Date/B : Other Permit: 1 11,A x13 Inspection Line: 503.639.4175 vt�.)14 I Date Ready/By: Juris: ® See Page 2 for Internet: www.tigard-or.gov s ,N,, ,j',tiSed/ Method: Supplemental Information TYPE OF WORT , %\ ('' '� t071 PLAN REVIEW r'� w.` I.. ❑New construction LJ Addition/alterati y sc..•' "' Please check all that apply(submit 2 sets of plans w/items checked below): 4 Ii ❑Service or feeder 400 amps or more ❑Building over three stories. 0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural U 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building amps for all other installations. buildings. Multi-family ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or TOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived system. 0 Addition of new motor load of ❑"A","E","1-2","1-3", Job no.: Job site address: 15750 SW Oakhill Ln 100HP or more. occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP:Tigard, OR 97224 ❑Health-care facilities. ['Supply voltage for more than ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: Project name: I ❑Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Fee. I Total I New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq.ft.or less 168.54 4 Ea.add'I 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: Limited energy,residential DESCRIPTION OF WORK (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 7.095 kW Prescriptive Roof-Mounted Solar PV Installation residential(with above sq.ft.) Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation 0 PROPERTY OWNER 0 TENANT 200 amps or less 100.70 2 201 amps to 400 amps 133.56 2 Name:Larry Byers 401 amps to 600 amps 200.342 Address:15750 SW Oakhill Ln 601 amps to 1,000 amps 301.04 " 2 y Tigard, OR 97224 Over 1,000 amps or volts 552.26 2 Cit /State/ZIP: Temporary services or feeders installation,alteration,and/or Phone:(971 )570-9957 Fax:( ) relocation 200 amps or less 59.36 1 Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration,or extension,per panel ❑✓ APPLICANT 0 CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, 7.42 2 Business name: Elemental Energy each branch circuit B.Fee for branch circuits without Contact name:John Grieser service or feeder fee,first 56.18 2 branch circuit Address: 3123 SE Belmont St Each add'l branch circuit 7.42 2 City/State/ZIP:Portland,OR 97214 Miscellaneous(service or feeder not included) Each manufactured or modular Phone:(503 )967-5786 Fax: :( ) dwelling,service and/or feeder 67.84 2 Reconnect only 67.84 2 E-mail: john@elemetalenergy.net Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name: Elemental Energy Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 2 Address: 3123 SE Belmont St Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr City/State/ZIP:Portland, OR 97214 Investigation(I hr min) 66.25/hr Phone:(503 )967-5786 Fax:( ) Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 195141 Electrical Lic.:C1228 Suprv.Lic.: 4786S specifically listed(%hr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: (-) Subtotal: Print name: Charles Harry �" Dafe:5/24/2017 Plan review(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: AkA,5_, TOTAL PERMIT FEE: Print name: John Grieser 5/24/2017 This permit application expires if a permit is not obtained within 180 Date: days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 05/21/2013 440-46I5T(I1/05/COM/WEB 4 Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined ... $75.00 Description I Qty.l Fee I Total I * Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 (� Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 nBurglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 n Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with 552.26 2 n Heating, Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 n V• acuum Systems* >100 kva—no additional charge 0.0 3 nEach additional inspection over allowable in any of the above: O• ther: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(Ye hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fee): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 nAudio and Stereo Systems days after it has been accepted as complete. * Number of inspections allowed per permit. Boiler Controls - Clock Systems n Data Telecommunication Installation n Fire Alarm Installation n HVAC n Instrumentation I Intercom and Paging Systems Landscape Irrigation Control* - Medical Nurse Calls n Outdoor Landscape Lighting* n Protective Signaling n Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC PermitApp_ELR_ERE.doe Rev 05/21/2013 4 City of Tigard 'I Building Division 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T 1 G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 15750 SW Oakhill Ln City: Tigard, OR 97224 Zip: Owner's Name: Larry Byers Date: 5/24/2017 Contractor's Name: Elemental Energy CCB #: 195141 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Located in a flood prescriptive path, follow Area plain/flood way? 0 No OSSC or ORSC for design requirements. El Wind Ex osure Is the wind exposure Yes If"Yes", qualifies for p "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑✓ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 1:/Building/Forms/Photo Voltaic-Checklist.docx City of Tigard q Building Division -47 $ 13125 SW Hall Blvd,Tigard,OR 97223 ,�i N Phone: 503.718.2439 Fax:503.598.1960 T I ci A R D Inspection Line: 503.639.4175 , 017 www.tigard-or.govIIINC DIVISION :JUN 2010 Oregon Solar Installation Specia10‘_,-uut Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 15750 SW Oakhill Ln City: Tigard, OR 97224 Zip: Owner's Name: Larry Byers Date: 5/24/2017 Contractor's Name: Elemental Energy CCB #: 195141 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ® Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? No OSSC or ORSC for design requirements. ❑✓ Yes Is the wind exposure If"Yes", qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ElYes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑ Yes the prescriptive path. above ❑ No 1 I:Building/Forms/PhotoVoltaic-Checkl ist.docx M ► • Is the construction material wood and does ❑✓ Yes Type of If"Yes", qualifies for the construction qualify Construction El No the prescriptive path. as "conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑✓ Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ✓❑ Yes the prescriptive path. ❑ No Is the combined weight ❑✓ Yes of the PV modules and If"Yes", qualifies for racking less than or ® No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ®✓ Yes with Section 305.4(3)of If"Yes", qualifies for Elthe 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is RoofingCheck the type ❑ of wood of one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑✓ of composition shingle. Is the roof mounted 0 Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for 0 No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/Photo Voltaic-Checklist.docx F • r Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑✓ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for El Yes the prescriptive path. ❑ No Attachment of roof mountedMinimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panelsWidth of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ❑✓ Yes If"Yes", qualifies for fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, 0 Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof 0 Yes the prescriptive path. surface. ® No 3 I:/Building/Forms/PhotoV oltaic-Checklist.docx • a ti Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Hyundai Model Number: HIS-S29ORG Listing Agency: UL 4 1:/Building/Forms/Photovoltaic-Checkl i st.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 15750 SW OAKHILL LN, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2017-00226 Inspection Type: Inspector: 199 Electrical final Jeff Grove Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 15750 SW OAKHILL LN, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2017-00226 Inspection Type: Inspector: 299 Final inspection Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor