Plans (164)
i / Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND I BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). Delete Line 0 XXX-XX GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. w o } BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O U o MAXIMUM SPACING(TYP) S z Add Line SPRINKLER MODEL(TYP) +-� = 1/2"PIPE SIZE w r ° HEAD SYMBOL(TYP) �r� =3/4"PIPE SIZE a'i, i�, Add Tee I I ` �I� = 1"PIPE SIZE 0 N��� 1-1/4"PIPE SIZE W 3 LL w o Add Elbow O .�.w zO ZNQ Wt��= � w3 3 No3 Add Coupling m CITY OF TIGIRD '.,2'P, Add Head - ,, -,.2\--,, v°',r-w3 Approved [x] o Delete Head Conditionally Approved ( 1 o Move Head - -0- See Letter to: Follow [ i _,I....o a o o, mgt AttachedN4z., t.°,,, JULo,oF z,,'7, f� Note:All revisions must be reviewed by Uponor 2017 °m. ¢i.. ''o Permit Number:th$TDD/7- 04> r y" L . Table F002-1 �o�,=ftm zo3 Multipurpose Fire Safety Systems Address: r 3)62- $W A...by..6.1E4w 't'�,t� si' OF 3 s .. z.>o - z oo¢❑ -z The Uponor Residential Fire Safety System is a residential fire protections �{ 13 P S( � l { `tl� a z z a o¢ o- �,F B /� 1.,+ /� BUIL.UII e.� '1 Yl� i fVzZ ft zR. sAy system installed in combination with the cold side of the domestic potable By: ^ 11;11 C'.. ,TJ�' iY i u e<E F o >8. i water system. Onlylicensed contractors trained byU onor can install this W o z.-, ,2 S t z z s system P �/• 7 ��z �r �F� o� G ¢ t4 I Q!"zQ oc�� i3z What to do if Changes are Required U az_m¢i.', d ‘ ¢d F If anyfeatures or obstructions require the addition or deletion of sprinkler yI z 5 c o r❑5 c z q p 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL '8 W d p z_E.. z z i_¢ heads,or significant relocation of sprinkler heads,contact the Uponor Design CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST O m '. o a S o z N' Department to determine if observed changes require a redesign FLOOR TO THIRD FLOOR FLOOR TO SECOND FLOOR < `z°z x '-w z U u-a (888.594.7726). ('',i ;� j - J „ .-- ,,,—,,,,x,'!, z 3 o MOST HYDRAULICALLY REMOTE HEADS Ili r. _ _ i,` / b. I: �cr , _ 4 ( \ \ X0 �Q82>85'a,< A _ / \ — HEAD# GPM PRESSURE REQ'D AT STREET 1-1 1 = / °p oYo >° `1� . t.t',d '—�, 1 \A 1 i �. I — -" ��-. . 4.�.,��� = � °c os oaxc sztd.� 1 HEAD H.4 11 28.44 ,17-1--- - /;( I I /� / 11 \ a o 'o °oza 2 HEAD H.8&H.7 20.0165 35.59 /�� I' �L i i i �� A ��T. >� > c °°o ' LI I/V 1 HY F � omn%� / \ r Floor � 11118ECL LENT GAS 1: � FS �e I�i �I �� i, '' -R RC-RESLF-14 A �r�L 1 1st loon \ , CRE RCRE F 4 �� �� 8 3rd Floor - �� 160 TOTAL 1 � ail - ri..�+ - \ IS RRESLF 14 / � C E�LFL1 �� �Il. SED/SING III E / \ / \\ Tandem 2-Car OFFICE COPY SENJU Model RC-RESLF37 LowFlow K3.7 Residential Concealed Pendent SS8261 Lr� + 11� �� �/ ® 15 K 3.7,162E°,7/16"Orifice,Maximum Spacing 14'x14' ! � I"P V \\ 1 Garage S.1 MAIN SHUTOFF RC-RESLF-14 Sprinkler head demand: 10 gpm @ 7.3 Y" P3jyr y� �� \ V ! li I 11 li , I 11 - VALVE LOCATION SENJU Model RC-RESLFIT LowFlow K3.7 Residential Concealed Pendent SS8261 4H''•:,',;- -.`4,- 1 ® - - - 1 K=3.7, 175F°,7/16"Orifice, Maximum Spacing 14'x14' �� as re i t�h /— r 1111 o \ _ RC-RESLF-14-175 Sprinkler head demand. 11 gpm @ 8.8 I = I � � r `� � ryry WRAP n 1-1/4"AquaPEX TO i 1 1 I T L 1, e - `v-s SYSTEM X111 �✓ Ll ESLF�14 111 \ 1� 6 M.25/ J tech. _ ryY F Ir I T1$ � ( �' �f�1 -I �7 1I a R2 /7 3 _l ;; V\ PPR F Mm \ �, 3, I' L tF .(, F . •"- I� S m V 1 %� F� �I ���# � t� 11 �� �,� �' 1 oC• F 14 �RELF- 4 �LE�� r Z 5 I 14 r- 2-2 �� a / E 8 �IIW ,� i 1 \ 38 -1 W 11 - 1 C utT, � ��,h. �_ 3 -� u i - cwi o; �1� , T�� T 27 1 <w� Q aom� �t as na RCRCStF141 V 0 �� ��� '11 11-------,-7'1';.; �� j�l 1 AZ. � � �� - T40 IAFA9 i z <f=,,,..,;, ��.21 H16` 1�" ;IF6 F7„ rt, 1 - P.9 ETI __ �,1 III Ce z •1 - R r I -7- � D o ..a CURRENT STATIC EXTERIOR WALL T 1JL 1 33 T.34 R SsTE 0� " a z WATER PRESSURE / ELEV-log' 1 ' a r� ��, �c" • M z�-mow 1 ! I1' l i , �` e` I- N 00oQ°xmw P i t LF 14 azo STATIC: 45psi 1 " N 0 1 I/a"AquaPEX II— V�� �4 TO SYSTEM • FL �., a s ' III M O> � -,ec�1I5 'rn., ,11� h W ° / TO HOT WATER HEATER �li ® E SELLING' 11 �� )��rr C/) z / S.1 1 R 4 _ �s�o � (7O °� ELEV-104' 1 • :,;- T14:1 RCR S HE i t _ l 'i z mmo a a 1 1 • I --w sn at t -Y Es x Y o `--�� r; ES F 14 FLIG,Dp m BALL VALVE - h'1 z wo i 1 '/a"FULL PORT i i1 ��S c i8<11 °2,a i'w P,.. I 0 �� ( m 0 4 : j. H m -Lw g,s, CO oliD ELEV-�°°' ELEV-'°°' 3 THIRD IRD_ F_ LOOR 2 SECOND FLOOR ---� FIRST FLOOR ,,=, S I VFa ////////////J SHEET DESCRIPTION 1 1. ' F100 ii - lI F100 ' 35'OF 1"METER 100'OF ` F100 ' n _ __ _ n ALL LEVELS 1"COPPER-K 1-1/2"AquaPEX 1/`r 1 _0 1/4 1i-0" 1/4 = i 1_u - 1 SHEET NUMBER 4 WATER SERVICE DETAIL = _ _ 5 15 F100 NTS 1,,.1," r © UPONOR - CONFIDENTIAL F100 ' - - Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND - BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). % 2 f Delete Line ®XXX-XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. o f BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. 0 a MAXIMUM SPACING(TYP) —rte ¢ z Add Line SPRINKLER MODEL(TYP) = 1/Z"PIPE SIZE LI''''-!'": C o.f HEAD SYMBOL(TYP) ��� =3/4"PIPE SIZE �, Add Tee = 1"PIPE SIZE 0 N P — = 1-1/4"PIPE SIZE W s LL w o Add ElbowOD u. , Jul z wL^�� Add Coupling Zn'Smo3 N 3 H ry W Q W Add Head 1 2 3 C,,1-w3 0 I ozLi <,„,. o0. 1,`„,x aDelete Head y2`,'4%.L.,`„;,,,_-,t. z7 a?zogoE.ro3�— Move Head Ou ,fz< ZOzJ. y<Qc4U: Or�-�3ti w x yc rotections o._ =. 0goU.0Note:All revisions must be reviewed by Uponor () ' oo �Table F002-1 oo ;° 'cz ^z aoa „ozMultipurpose Fire Safety Systems omna,o0 °ooooCaaiThe or lllal Fire fety eresidential P Ce0 system installed in combination with the cold side of thedomestic potable nom _N<o water system. Only licensed contractors trained by Uponor can install this f o, r,,> < z w u system. „y aoaa_�,�: Nz�-� xr wa QW_uNoz oo�a�oz What to do if Changes are Required 26, U d z C uu<5'i 55 `'-p If any features or obstructions require the addition or deletion of sprinkler 0 z r u o i o < heads,or significant relocation of sprinkler heads,contact the Uponor Design C t1,2:.'-''a 6 LL_ a i o,�S S Department to determine if observed changes require a redesign E e z -> s a (888.594.7726). �i9r!WW-ps p°z x_J ID ,. 1-PR U L ZaZa p. mp ❑,�2 1 r Gn :ABOVE t 1I o .>-'w.2 ¢ - _ �L 2 i L{ ft, c-J 0 .,: G __ :_... _ ocJp�z o Dyo .�P.r0 r- L _ - -i 1 - — : a- L4 ',1 ,� 9 o oa J 1 cF� Ili1 _� L r ��1 `�P yi_z3 -o - 1 1 rz>zo�a ,h' z odw. z�ru<uu?z �=¢ w a H "f R�-R7LF-14RC-RESLF 14 4 L:�i p I TILE :EA rL' =ND R 4 r RC 'ESLF-1 h RC-RESLFAI4 I 1 Tandem 2-Car 1 5 N. ''�1 IJ cfi II - �q I , d. dd_ ) 5.1 MAIN SHUTOFF — 1. i�,,ti Garage III --, T 7-T VALVE LOCATE N \ p y �� I,^t Lf f Y y� \ T.24cM.25 T26— , ' f / F z � „� `� 1 C _ DP----D<,: . to1, a, � , \ \ / / Aqua SEEM c c .... :7-1 BELOW CEDING 111 . - 3 RC-RESLIT I 'WRAP F A�� 1ilE_I FF F.3 F.2 _ 7 �1 LD -_— , --__H l �` 1”AQUAPEX INTERLEVEL „ 1Cfiect1. FLOOD ACOVE.t II c et. - / II ''f-,.0 �C. ,. FLOOR TO SECOND FLOOR // -i �I;.{�+ > CONNECTIONS FROM FIRST` Y y�I 1 Q /£ b �9 I�t[[.t�t�11 .F.F�rI�.`- f CJS' �i CONQUAPEX INTERLEVEL N ECTIONS FROM SECOND / J - - `� 42 'd6-R 1 1 C�. \\\\.—7.7" I'� .,n :1 1 5 Tr ^ a 11 FLOOR TO THIRD FLOOR `, '� �� i F SF r. �,.. a � � � / F- T27 ! 1�. 8 /i/ ;IPEP DETAF• W ao� I • .,� ' / \ •a \ �� �/ Tei\\ Y a o o m T 3, s z r II rV `� _ e`er`-' � �� z P-1 �''/"''‘ 1 / II`'_s • T � r ,Tori 1 ill T39' << T.40 \ °III ~ f LL • ,,' �r _ IL T 33 F LA T.34T_ n �a .k-,b<Q; w a 3 1 �< �� I 111 r\ {- . i C\ FC CFoJLITI:J J, III \ V U U V Q UI ZV p 0 0 0 x u �' RCR r N P) w 'u �X ti 4�� ,,,,I p Gc i� 1 -4 � M al % Q\ r ,L..,CI .( ® _ 1,[� „I8,' 6I ':1 111 i' .$ .. w�E134�.� RC f�ESLF 14 p o 11 C � LF 14 ' -RESL { L1 r e� .— J7; b F"i Z Y° d 8 �= mw ry i 1 x 'r �., fL � � DC D1 Y.. zip CEr I41 - _ , L Fx RST 0 c _ - m f ru `u Ho Q m w �7 F U imo==LL o 1 � WALLEr.: � L ��r 1 1 kT � � � C3�s5a r zou Yp.,El z 3 THIRD FLOOR z SECOND FLOOR 1 FIRST FLOOR SHEET DESCRIPTION F101 ALL LEVELS MIRROR 11 = 1,—OH F101 1 4" = 11_OII F101 1/4" = l'-0" SHEET NUMBER 5 0 5 15 I- © UPONOR - CONFIDENTIAL F101 Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations cr AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements `n Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor ` z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic ` p SECTION 3.3.11.3. --..-- -- y u Required.If Push-on Nut installation guidelines(Provided in Contractors Documents package or online 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, v _° ` 1%q"Min. at www.Uponorpro.com). o Use The 2 To THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND p / 11/"Max. t > Screw Holes. Planter Box Window,BayWindow or Similar Feature. "' UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. D-. C Bottom of Mounting Extreme Temperature Installations - Bracket to Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or If no additinal floor area is created No Additional Sprinkler is Required. 9 @.,u 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Ada-ter-~ - other areas exposed to temperature extremes of heat and/or cold. Follow a°�w m Sprinklerp -/ p p / 8'-0"or less O .:N>-2'''11 RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Fire MountingBracket '" the e recommended o pore nt weather installation ttmn instructionsrs. Because isolate and / PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE ��J�� 1w 3 a w� SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. this RC-RES-16 ,, system also delivers domestic cold water directly to plumbing fixtures, ® \ .�.,°' °1 SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" 9'-0"or less >,°�,'`�°,z a } Uponor highly recommends that you protect the tubing with adequate / '1' c m g� Full Course q 1 i °1 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Screws ,L7 n 7 insulation in warm weather areas to minimize heating of the cold water \ o rn v w'� NFPA 13D 2016 EDITION. In Bottom Holes supply. o o En QsN o \ `s` / w '�'9 m w 5. "STAND-ALONE'OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. Installation methods include,but are not limited to: • Tenting over the fire sprinkler piping. I o \ C:°++ w 3 I Lead-Free Flat 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR - r„ • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft",be more than 2'-0" DAMAGED MUST BE REPLACED. Concealer Senju L Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the - o -' Sprinkler Head 4 ¢w s Cover Plate sprinkler.No Additional Sprinkler is Required. z m ' ,1-21. ,-2 o x u¢ 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to o> r..�c z= o 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction Protect all components during application.Consult with the spray foam o x w manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From ,.1.11V °51,85 y z 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources =LL o 2 o a¢c o o W>o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance z LL,,7,;,0 m¢= r m c PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX L'Brass Fire with local building codes. z o°¢o m o= U 0 AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler'dapter Tee Fire Sprinkler Adapter OrdinaryTep. Intermediate __ -a^> z4 ¢ FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM a , Push-on Nut Heat Source Temp. Temp. ` z r j c'V V V F- WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE -�- 135°-170° 175°-225° c ¢°o¢ y w m Bending PEX Tubing ozz¢°5a°°J�'k THIS SIGN". 5 g 9 Side of Fireplace 36" 12" o ° C 1%4'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times y�LL o¢ij¢F o o>¢¢L i Front of Fireplace 60" 12" W°°-m05N�¢za3: 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. -- 1/ Max. the outside diameter(6 x OD). ° Fire Sprin ler Adapter - 2-• Bottom cf Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" N ¢ ¢d h Bracket to=ace of Truss Kitchen Range 18" 9" Q¢ z z o o^a >3 z 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket J tubing to facilitate 90-degree rigid bends. 9 J y z¢N C_F a o c Wall Oven 18" 9" U dz:7.1 .��-¢� 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1/2" 0 ® BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE / Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" w a L 9 z°G z zFull t -\-- ao ¢U�-,,,LLLL RESTRICTIVE SPACING LIMITATIONS. Thread S.rews �y I I Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" G°i o z F u ->z x u In Top Hales t__7 lL_1/ TJUninsulated Hot Water Pipes 12" 6" 5`0065y 5`°69249 3/8"ProPEX Fitting 2.. x9r oo�9°90V°5o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12" `= �`z d �,�r o u c�' MOUNTED OBSTRUCTIONS. 1/2"ProPEX Fitting 2 1/2" = r d o° Q-'2 ° -� Front of Hot Air Diffuser 36" 18" 6°o6,'i,¢6Xwzw .Outs, 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE - 3/4'ProPEX Fitting 3 1/2" Hot Water Heater z z o m u y o Lead-Fre:-Flat /' _ °o o z c °, SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Conceale.henIu \'`_. 'r" f 1"ProPEX Fitting 4 1/2" Furnace 6" 3" >w 99 w>¢><,=o Concealed Flat o o s m ¢_ i-. Sprinkler Head Cover Plate 1 1/4"ProPEX Fitting 50W-250W Light Fixture 6" 3" �4 ms 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN g 5 1/2" 9 _ >u,, v,,,t_° CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 250W-499W Light Fixture 12" 6" u c?° .,z z u a 399 54_9_ THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. �_a% z r o a��, \ '7iru0¢u0u=OZOZQ w 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. ''" \ • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEX tubing(white)and ProPEX EP Fittings and ProPEX"' I THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY Conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: rgos (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. V p-174 ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open ^' m E (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT2(1.7 Mu) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. 00 (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ I \ THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at m 'Iaximum 24 inches(610 mm)on center 'I 1.55" / 1.66" 'I ALONG THE FINISHED FLOOR. are used. ft (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation Z.. -3,. Hanger 1" Hanger PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). o (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Support Spacing: (3) Q Metal Tubing Support. AnchorA AquaPEX Tubing y g pp g, -o 3 THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE ( q g Securel Enough to nt ort the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal supports for sharp edges. Supports Every 32",if Horizontal Runs are :' 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor A uaPEX° with supports. 1. AlongHorizontal Runs,Install D • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 9 Y P q tubing Allow Continuously Supported,Place Tubing Supports a[Six-Foot Intervals. enough tubing for freedom of movement to expand and contract. Along Supports Every Four to Five Feet,at Each THROUGH 8.3.8. 2. Vertical Runs,Install g • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT2(5.1 M')AND LESS Floor and at a Mid-story Guide. E.9 • • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT m z O1 MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test z. 00 (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT2(2.2 M2). The In-line Flow Test can be constructed on site. It performs a flow test toILI a 9 o 4 (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). 0`w° m MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. u r-rn In a safety purpose system a single control valve controls both domestic and z w w • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND I Q i. n fire safety needs. -'m 0 _ 9 SIMILAR STRUCTURES Y t o m Utibin AquaPEX z • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE q a z.n F EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubin • CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, CeIw 9 CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING 9 9 PURPOSES. z ui m • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR / • a w 8.3.5.1.2. w H u i • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING j w a¢0,'f: z 0 '" UNIT,NO SPRINKLER FUEL-FIRED SHALL BE REQUIRED IN THE CONCEALED SPACE. O O F- •„F N F z 0 ~o w N • • 8.3.5.1.2 WHERE FUEL-FIRED E UIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE V H a¢a vii z p m DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling ProPEX Fire N INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter inn m EQUIPMENT FROM THE OCCUPIED SPACE. i� w L • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING ATMale Threaded Coupling --- 1"Ball Valve Ce 7 4 ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. To Hot Water Heater P 9 T, (� 5 • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING Tee with Water LLI ,^ r,/ CONDITIONS: = w _'-�'r Tee Water V' LL 3 J n (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED ti Pressure Gauge > O o Sprinkler Orifice - ,s 100 FTs(2.83 Ms). - m ll u (Optional) ll m O La sr (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS Z 0 ow Y>_ m a �/ ti'i m AT THE LOWER CEILING ELEVATION. Y Uponor Warning Signs Flow Test Ce 1--I F w o, (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE To ensure the system provides enough water for proper fire sprinkler 0 cc .,a m ut m TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. ry (4)SKYLIGHTS NOT EXCEEDING 32 FT2(2.97 M2)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. performance,you should conduct a flow verification test. o • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS - LL 1-•i-' Q >,E w Note: The NFPA 13D Installation Standard does not require flow '1,' a (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR - 0 q m 0 i LL p ,o verification. ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED -' H z F PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. 22 Main Fire Sprinkler Z G 3 9 S S Q Before performing a flow verification test,confirm the water pressures by a F • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING - z = Shut-off Valve c z=w d o contactingvilabethe ress and hr the pressure of your hl city. Ensure the. a o u m z ro EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. available water pressure matches the pressure used in the system design. Note: The sprinklerplan indicates the most hydraulically SHEET DESCRIPTION • 18. INSULATION GUIDE LINES PER NFPA 13D. - p y y remote sprinkler • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS 0 USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY .7c w your local code. INSULATED TO MAINTAIN 40°F. •• F1.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection 0- GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. o CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in 8 PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and 9 Troubleshooting. If there are any questions please contact Uponor. f, © UPONOR - CONFIDENTIAL FO 0 1