Plans (156)
• Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND Ihem BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). z 6 Delete Line O XXX-XX GREEN LINES== INTERLEVEL CONNL-1 u } BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O o MAXIMUM SPACING(TYP) ✓ = 1/2"PIPE SIZE Add Line SPRINKLER MODEL(TYP) w IL HEAD SYMBOL(TYP) —n— =3/4"PIPE SIZE a�C,uu Add Tee == = 1"PIPE SIZE 0 a u '4 = 1-1/4"PIPE SIZE w'LL w o Add Elbow I>V`v Iun tx,=v Z Add °°ling CITY OF TIGARD a 2 4.3 �N RECEIVE!'" o��W3 Add Head - - - - Approved [� o w Zug•. V=irC �.I.,Q Conditionally Approved [ ] N z-4o��00! Delete Head c�-m > °ezao" See Letter to: Follow [ ] JUL _IG)'' �sm< �`°��� Move Head [ ] ,....0_,..,„„. ¢y w T z ,LLuzs x Attached CITY OF TIGARD m a=p I I �VQ:.U,..,r�iiKmC Note:All revisions must be reviewed by Uponor -g<c m p c C'' Permit Number:yh3T7ot�- On l o BUILDING z°°,o,a= o3..Q Table F002-1 y Address: IVt10 sw 4uh«"6"//4,e. #u-� DIVISION _ >,;nw-=�= Multipurpose Fire Safety Systems ^ ? u<m<QmmeQ-•2 The Uponor Residential Fire Safety System is a residential fire protections B /�4� f'y„• "7—'0— et -o z w z F o o-'x.e ,‘_,,,, z system installed in combination with the cold side of the domestic potable Y• - ''"L.. r I W m m y> <ro 5 z 3¢w water system. Onlylicensed contractors trained byUponor can install this S”' FTS @T o.� =S a` . E system.Y P •�' �y 'S OF1'iCE COPY a dF'ozoo,a�� z (� 'P� COIL Y J wza Noo��ewF° o r What to do if Changes are Required el`a-wh ?yco'u z> If any features or obstructions require the addition or deletion of sprinkler 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL N m<a a o=.moi a o d=Q`'a heads,or significant relocation of sprinkler heads,contact the U onor Design CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST O m x¢ z x'm G 9 P P 9 � , n: h�5oz s,cw z.c FE (888.594.7726). FLOOR TO THIRD FLOORFLOOR TO SECOND FLOOR MOST HYDRAULICALLY REMOTE HEADS hhh' ' x c z o Department to determine if observed changes require a redesign m WALL PER ` I ' t i oa";g z"Qoh a HEAD# GPM PRESSURE REQ'D AT STREET ' F / L X// 1 VA4.l �. I "� �, _r ; ( 11 ��° G�, oz�z�m� F �� I VL 1 HEAD H.4 11 28.35 _ / II \ / a 2 HEAD H.8&H.7 20.0023 35.79 hs 1 I 2 / ., ` i ���<�� x_a0z< L \! r.� _� 11 V >. z> o o� c z �' // Ii� \ \�I\ \ 1H O ®H.9 /� 1\ - \ \ - `rv,,,,-., ";t raw w / < 1 1st Floor - ,.. .�II I�I 1 \ \ 1� AND - � -�- -� RC-RESLF-14 RC=RE F-1A/ � + 7 2nd Floor _ /�J{/ 1 1118 '� 16 TOTAL - %.�`/,�. E'. \ \ FL trtFF� Itrl �� �II�� 1\ I.' J� r F:_Y L L.; -�� 1 \ \ F / I here by certify that this plan,specification, R RRESLF 14 Ci- Lr I (� 11 `� —�,- or report was prepared by me or under my 8 3rd Floor SENJU Model RC-RESLF37 LowFlow K3 7 Residential Concealed Pendent SS8261 --- 2_ I I f ' 1 \ \ ane . C directsupervision and marl am NICET SW's NE �1 � F MIN RATED- Tandem 2 Car K=3.7, 162F°,7/16"Orifice, Maximum Spacing 14'x14' I I it c - „. S.1 MAIN SHUTOFF Certified atLevel[v. 0 - - - 15p eIr 11 Garage a Sprinkler head demand: 10gpm @ 7.3 -4/' ;, ( II-L/1.__j I / 11 RC-RESLF-14 p 11 / �'' o,. vALVE LocnnoN c ii_k- _ IN£ r v. -#-i f1F',..I A Brent D Kotula r, SENJU Model RC-RESLFIT LowFlow K3.7 Residential Concealed Pendent 558261 i It- Date: g No.usa89 11Reg. 0 - 1 K=3.7, 175F°,7/16"Orifice, Maximum Spacing 14'x14' ° 1 e 40th; II \ I F,F I F ALL , i RC-RESLF-14-175 Sprinkler head demand: 11 gpm @ 8.8 1_ , '..7,-74.3,'''c— 1 T24-- 1\I a 1 MI 1 1-Ya"AquaPEX TO 1 3 1 l4 f _,ESLF 14 1 \ r 6 M.25// I .i BELOW 2H2E/SiN2,2: 1 1 4 r SYSTEM s T �8 �l,i 1 R2 /i<3 0 cul— -- � --_� 4 1 1+ F� LCI RUN _ ��,n'` r. N 1 �p' H - �4. i RC RC$LF-14 \ 4C F1 W aim 9 wog �I�c 8� VT 27 1 P -••E'..-F-14,-.-1::::.--41.,,,I 30 3 _ _ 3$ u, "'/ //_ GGGGG �, I`!I fid Jr. J '1'v " �R IIhEEV I =Y R REF II�' T.4U U8 F° s '3g l IAiLS ko o ` I'. 6 � F9 t41 L _ .. b' F;: 76 F7 I _.__ N - , :w- LI T I p W Z 2 � � II T34 „c �3 IW H «Gro� a CURRENT STATIC EXTERIOR WALL T ,1I .33 46, M a w u ELEV=109' I f z 8 WATER PRESSURE \ / 1 c i F-1 0 S o iT. C I rfl LTED - o ^1 O m STATIC: 62psi k NIS o — L V E •�tra TLR R _, 'I ',_o �.� i =rV /a�, r� I I IV D N / 5 1-/4"A AquaPEX 1 .0 TO SYSTEM ` , "N L ` �;`, �I $ q IId ftt 1 p �fi „\,,,,,,,,,,,,,,,k4,,, ! W rl s.1 TO HOT WATER HEATER RC-RESLF-14 6 ��/ a �o sc CZ 3 I •�E_ R RESLF 14` f� - --1 , ■ _ V' 0 m H t ELEV=104 1 �RC.RE L(11 -- �i' '�a `4G RES � I—I Z / L 1-/4”FULL PORT i1-1N. II . I '. L 1• Q Ce F w m o BALL VALVE L f li b i L _ ��� .� 1 2[ t 11 ......._ L /'� B'O. ; m o m in.moi.-'., o L F - �' + z-,_,_ j.I� I' L J Q � i � L 1 � �/ ;g EXTEN7 2" LL . t"r,nF � I � � 1 � - ra � II iII �,u I � � ���� Z3uF ELEV-100 ELEV=100 ,/////////// 3 THIRD FLOOR z SECOND FLOOR _- FIRST FLOOR DESCRIPTION a = ;7 C.) .--. ...._ SHEET DESCRIPTION 1"METER 35'OF 100'OF `' F100 i/ " _ i I_O" F100 1/^n = i I_On F100 1/^n _ i I_On ALL LEVELS 1"COPPER-K 1-1/2"AquaPEX 1 `t 1 1 `t 1 1 `t 1 i SHEET NUMBER 4 WATER SERVICE DETAIL 5 15 F100 NTS F100 © UPONOR - CONFIDENTIAL g F' a Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND ` z BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). o Yw 0 XXX-XX GREEN LINES=INTERLEVELCONNECTIONS/SUPPLY. O w u Delete Line ` BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. o MAXIMUM SPACING(TYP) = 1/2"PIPE SIZE 5 0 o Add Line SPRINKLER MODEL(TYP) a'". p HEAD SYMBOL(TYP) —n— =3/4"PIPE SIZE a m Ua u = 1"PIPE SIZE 0 a� Add Tee —.I.— = 1-1/4"PIPE SIZE 3 LL w o Add Elbow E. 5 >N rl7�za C � v w 3 — Z` '03 Add Coupling v w- E� w C ~W 3 2a Add Head 1 2 3 a om Zy Vw,z Fri= o� zYwz Delete Head - - N o z O o o , v iO�--.-0\ uacziz N000'ml8w < ozaoc Move Head �� w ar",00>Q 1oNozc `13�mz ooma_a5wo Note:All revisions must be reviewed by Uponor ~'o¢ E z o e v �,yc �X< Table F002-1 ❑ooaz�5Fz Multipurpose Fire Safety Systems o z z a c o_o zw Uzn Qui m .'O The Uponor Residential Fire Safety System is a residential fire protections 0:EU_°o z o¢i'..''-g-' ,'<„F C system installed in combination with the cold side of the domestic potable W H o-m-.9 z r-z 5 c L, z Q water system. Only licensed contractors[rained by Uponor can install this - N o t=5 o d t V<7 <c system. Q d'=rozooiQR:?P.3z U`tz::El wE,', -,'¢ What to do if Changes are Required ���u ❑»oc�z`y� If any features or obstructions require the addition or deletion of sprinkler C o Q H o o$i a c 0 o z`�5 heads,or significant relocation of sprinkler heads,contact the Uponor Design . z w o z_-c-•� r.--t. Department to determine if observed changes require a redesign = o z N o o E_~ (888.594.772b). '' 0 3 0 °5 it n a c r ,': I Il _ 25 �N� oo z°z _- „,1,—; y -- 1 .. . tt PF :-/,:*, R --.. i,z�d<Qo2 0`' °t 1 � I ��` a- tE ftCLELCh 1 ,l F - I �� .. a 1 f71 > m w� oa II . 1 5-05: 1 �'.IE ' - 1 �2EF Ts 3, oo�Q III' H.9 H.10 yll I 0 '� ” °«°_.=.x< E f 11 I� ii "' = VE Ili H 1' L � f -R=SLF-44 1 RC-RESLF-14 �L ( : ii b I ! 1 l LL irrr - RCr ES F 1 RC RESLF�14 { V I here by certify that this plan,specification, - ill i4 - or report was prepared by me or under my i I ' FI 'F� _ J.. Er q :iidirect supervision and that I am NICET - ( REI II T _ J Tandem 2-Car Certified at Level IV. -M-'-;-i° 1 G : S.1 MAIN SHUTOFF + , , 1 Garage m (� TEF VALVE LOCATION r: �Nc �_ ( Brent D Kotula T47 I °� _ � I ,s IL _ if 4�� 'III C 1 .moi! ' - r. a 1_ L FUSH: e Date: Reg.No.113889 ll 3. L. g�r 7 # - .24 113 .Gi) l iE CEIHNC, S:- _ M.25 1`26— A uaRP)C D " o 1 RC RES t �,I1w�� �� '�.. ( �' b N' ` ,--• 1� q SYSf M .: Ct E r INIV 1. 3 ( ........_ F—I' q�3 ' _,!\ ti / / F.3 �•2 - ` ` ` CONNECTIONS FROM FIRST`/ f M�C�.- R 1 - FLtOr.N 6,,_.tv y FLOOR TO SECOND FLOOR - 1p — fI�, Cc�l 1"AQUAPEX INTERLEVEL / " 4�" / r_ I a r - — SLF 1:4 // l4� � F m f _ � F F� i4r -'I� � CONNECTIONS FROM SECOND F eel ,RC_RESLF 1 � °"� �� o, / h l r ' (/ / FLOOR TO THIRD FLOOR --,.„.„.,,,.2..___ T 27/ I 0 1 �� / i. Ft ' w a'3 i o /l - 1445 F -.- r SMS \ 7". 9 — _ `< u o,� <`'L9,,'-,r` o11 E A •� T BV ii T 39 _ -:-a II: 1 ft `,6;tt ( VI 7 ( \ U�I'� Ji til 17,7X/I �� _ aP r ': - -r -:. ,I, �urTloN�� z w �� �� � . - m P T.40 f I` ^~I___I i5T ( � '1 r 4n� -R ry' ,_t tai • fl.._ A —x l W z a F Y =� o �R r fl 22 --,;t,,, ,.---" ' 010 ��' 1 tH ..� )1-741D, M k .9' ' L1J G=o L k #; j T.34 T 11 ,. „I' ``_, F— f— M a~ a~w � I1 I � c� A It" '. Mx � ,kro, ! '—' N °paa�zo " ;3 u J SEC cGiuNc' I1, �; o z N U S C SI,Z. 1 D N. > c �s �r JRIPLEE, E ` r I g!I H I w .� ce ° RC-RESLF-14 I a i 4' �� i°' � - ° Tt— 'a C-f-tE4F-II4 0� [] m m o L R4 RE LF 14 II R RESL r r a ll z o}� m o II __ 111 I `� �. ( �'1 Ce 1---1 \ 1p a " µy. ti 'll• I ` __ �� " •L Or_.-ter.E �I °' m w 81 II 11 )17===5--1-� I2 m W _ � fF �� J Q�r� :JT N �I =w ~ ;.7--,,,,%-i- a-6 S T OF F a cS�i ., 1 4. E y -5i 9=L' , W N55,2' (NEI)4 h „:�sT 4 6 F ',-,IN!EXT I�• ) r - I"I z 8 F l o u g m i 3 THIRD FLOOR 2 . SECOND FLOOR 1 FIRST FLOOR SHEET DESCRIPTION - ---- --- -- - __ ALL LEVELS-MIRROR F1o1, 1 411 = 1'-O" FlO1; 1/4" = 1'-o" ' FlO1. 1/4" = 1'-O" SHEET NUMBER S _ D 5 15 O 1/4"=1'_0" © UPONOR - CONFIDENTIAL F101 F- i Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations TMSee General Notes 8.2.5.7 for Architectural AquaSAFE GENERAL NOTES: to areas subject AquaPEX freezing,tubingnompldel taken in lation. Insulation laspaces C ProPEX LF Brass Fire to cover Uponor completely with insulation. Feature Requirements u, Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor _ 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Fire Sprinkler Adapter Document"Uponor A uaSAFE Attic Insulation Guidlines"for attic Blocking Maybeq ` / O SECTION 3.3.11.3. , Push-on Nut ` / O w u Required.If installation guidelines(Provided in Contractors Documents package or online Blocking is Used, ' ' 1 at www.Uponorpro.com). O 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON -�� 1/q"Min. i i a..z THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Use The 2 Top !i 1 Y2"Max. as n a Screw Holes. ) t Planter Box Window,BayWindow or Similar Feature. C 0 UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. D- C / Bottom of Mounting Extreme Temperature Installations a.. O Bracket to Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or If no additinal floor area is created No Additional Sprinkler is Required. a 5 w u 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE - a Fire Sprinkler Adapter- 1- other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less D S S S RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket .L�l// the recommended extreme weather installation instructions to isolate and / 0 u'j PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE w 3 LL w O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC-RES-16 �} + system also delivers domestic cold water directly to plumbing fixtures, ® \ Cie t u'o SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1/2" _ 9'-0"or less I, i,`O„ a Full Cour-- f i } Uponor highly recommends that you protect the tubing with adequate / 4" _ W m n 1-�� insulation in warm weather areas to minimize heating of the cold water rn m v:c,.1, w 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Si sews l 7 ,,,\ A J,0 NFPA 13D 2016 EDITION. In Botto Holes supply. \ o m / a°i J �:. \ Installation methods include,but are not limited to: iN L\ m\ r'''§):3°1-i4,19 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. c Lead-Fre.Flat - • Tenting over the fire sprinkler piping. 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR !II Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 fiz,be more than 2'-0" DAMAGED MUST BE REPLACED. Conceale•Senju ` •y Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the5 a a o�, Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. z m o w z 0 r Z,< c iY, z 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to i,r < a 0-o C r Senju RC-RES:Traditional Wood FramingConstruction protect all components during application.Consult with the spray foam x°F o y 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. NFPA 13D Table 7.5.5.3 Distances From a 5 z 5 manufacturer to ensure compatibility with all products before application. <L z¢o z Heat Sources Oo z�Si 5coo tea° 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Consultation with local building officials is encouraged to ensure compliance 55 u LL` a F z x m p WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND with local building codes. cJ o<° r `�0 3 PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LP Brass Fire Fire SprinklerOrdinaryIntermediate z M 0 AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Adapter o o a --z prin pHeat Source Temp. Temp. 0 z�r o FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM . Push-on Nut 135°-170° 175°-225° o o¢ "m z z WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE -�~ i z z< p¢°o¢ =F Bending PEX Tubing Side of Fireplace 36 1z" o-°°z a THIS SIGN". ) c t0(�"❑zoawoF:¢"z 1/4'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times o 5 S -S_°F-> <� YFront of Fireplace 60" 36" W aaSa> <z z3^ 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. ---.-- 1% Max. the outside diameter(6 x OD). p f❑- . o-7 z Jaz s a Bottom cf Mounting Wood Burning Stove 42" 12" LL.. z<° . ° : Fire Sprinder Adapter - Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX X z-o<d-z z F,a- 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting `-...N.._.1 am/ Bracket m-ace of Truss g to facilitate 90-degree rigid bends. Kitchen Range 18" 9" J d z u o p`o , .'7,, '-"z Bracket tubing Wall Oven 18" 9" U 5E-w¢w: n��� 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1/2" O ® Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" _ ��y Q''"50,-,000,,,,C, z BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Cour I _ t ,-N d�.,<_z°J: u RESTRICTIVE SPACING LIMITATIONS. Thread S rews I r I Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" w z w o z_H u z r->u F d In TopH les lf kE_V U Uninsulated Hot Water Pipes 12" 6" 55x50555 o3"m'^ 3/8"ProPEX Fitting 2^ 1 W-e,J Z<w z o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12" v a m¢� i�°�, 1/2"ProPEX Fitting3G=�°< c'='' MOUNTED OBSTRUCTIONS. 2 1/2" \ Front of Hot Air Diffuser 36" 18" ' ¢ 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3" a z�> o z -o w Lead-Fre-Flat - .._,,,. , 9,,,0-,40,,-,� - ° SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Concealed Senju \ , 1"ProPEX Fitting 4 1/2" Furnace 6" 3" .>m o .¢ Concealed Flat J,c 0p s t-<S, Sprinkler Head Cover Plate 1 1/4"ProPEX 5 1/2" 50W-250W Light Fixture 6" 3" - >; v m z z z m`� 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Fitting " x z-o 5 m a CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 250W-499W Light Fixture 12" 6" ¢s- h o p o THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. w z>`z o 5 5 - A: \ v` au�_� `a w Exposed Installation Requirements. a 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS EXrn • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor Aqua PEXr"tubing(white)and Pro installationPEXT"EP Fittings and 11 o ingI THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT2 PER SPRINKLER. Brass Fittings are approved for exposed where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: = p (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. ,v /// 1m ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open ^' !/ m I here by certify that this plan,specification, (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. // "� m or report was prepared by me or under my SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (/ direct supervision and that I am NICET (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT2(1.7 M2) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. 0❑ Certified at Level IV. n (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ \ 'I THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55" 1.66" 4, ALONG THE FINISHED FLOOR. are used. Brent D Kotula ni (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation 1" -3r' Hanger 1" Hanger PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). 4 9 g Date: Reg.No.113889 (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER ni SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. Tubing Support Spacing: i (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal supports for sharp edges. 1. AlongHorizontal Runs,Install 5 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. Supports Every 32",if Horizontal Runs are ' .c • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor movement tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. ! Y THROUGH 8.3.8. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each `-' • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT2(5.1 Ma)AND LESS Floor and at a Mid-story Guide. 0 • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT m a -+ MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test • °' (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT2(2.2 Ma). The In-line Flow Test can be constructed on site. It performs a flow test to W a of 5 c A (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-B). 0`° - MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a multi-purpose system a single control valve controls both domestic and r 1 w°n' H • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND v " it fire safety needs. M 0 0= t SIMILAR STRUCTURESp O o m^�' �>- • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE % \Tubing r AquaPEX / /r a ,,,F EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND \` z CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, CZ kipm Q CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING j 0 PURPOSES. j I z o '+' z ,p • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR / Y >F F 8.3 5.1.2. z u u a • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING -..--. % ///� �LLJ y'� z a a w UNIT,NO2 SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. L 1� O O o S O x m S " • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE 1 N Male Threaded CouplingProPEX Fire Z N u u u 0 d ut z0 0 al DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Sprinkler Adapter Z 0INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED w EQUIPMENT FROM THE OCCUPIED SPACE. 1"Ball Valve z m • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT -To Hot Water Heater Male Threaded Coupling -CI o ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. 7, - /" Female Threaded W T� t • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING lil_ w ''F/ Tee with Water �+ c CONDITIONS: - a Pressure Gauge > (: O A (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Sprinkler Orifice - v O F (Optional) 7 K E O L 100 FT.(2.83 M3). II I F•-I L o y y (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS > AT THE LOWER CEILING ELEVATION. E Uponor Warning Signs Flow Test Ce 1� 0�/ ,''i•-•!..3'''. (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE To ensure the systemprovides enough water forp 0 I..L °'a m"' - m TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. y 9 proper fires sprinkler u�.". (4)SKYLIGHTS NOT EXCEEDING 32 FTz(2.97 Mz)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. t w performance,you should conduct a flow verification test. J • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS " ~ /r't L'-c, m f 'rw' ~ (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR _ p Note: The NFPA 13D Installation Standard does not require flow D V ?m z z v_ a verification. v o 0 ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED " H >:,Fig i-'- i Main Fire Sprinkler 3 w 5¢ PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. _ Before performing a flow verification test,confirm the water pressures by C Shut-off Valve o o x w'r a p 7-1 • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING z - contacting the Water and Sewer Department of your local city. Ensure the a p V�, EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. available water pressure matches the pressure used in the system design. F. 18. INSULATION GUIDE LINES PER NFPA 130. - Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40.F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - 2 (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY 5 your local code. INSULATED TO MAINTAIN 40°F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. Z CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40.F WILL BE MAINTAINED. I Contractors Documents package or online at www.Uorming Test)for Lmore information on Flow Test Setup,Assembly,Performing the and Troubleshooting. If there are any questions please contact Uponor. © UPONOR - CONFIDENTIAL FO 0 1 ,,,-