Plans (126) SCOPE OF WORK FIRE ALARM EQUIPMENT SYMBOL LIST 8I0 MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT RECEIWD NOTIFIER WHICH INCLUDES A NEW FACP, SPRINKLER TFLOWNG, AND TAMPER VALVE SELF-CONTAINED SURFACE MOUNT 54" TO TOP OF HIGHEST MONITORING,SMOKE DETECTORS,STATION HEAT DETECTORS, AND ELEVATORACONTROLS. MOVE STATIONS, FACP FIRE ALARM CONTROL PANEL N REV 3 0 19"H X 16.65"W X 5.20"D USER FUNCTION AFF „UL I. " W017 EXISTING ZONES AND EXISTING NOTIFICATION TO NEW PANEL. SEMI-FLUSH MOUNT �+ p n FIRE ALARM ANNUNCIATOR PANEL NNOTIFIER0 SINGLE GANG, DOUBLE GANG, OR 54" TO TOP AFF 4+�T� t� E1 4" SQUARE BACK BOX L3UIl..)IN OVION CELLULAR DIALER DSC SELF-CONTAINED SURFACE MOUNT ALIGN WITH OTHER EQUIPMENT �`� D23364010-CF 11.5" X 10" X 3' Q GENERAL NOTES WF WATER FLOW SWITCH BY OTHERS MONITORED BY NMM-100P r ` 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA Q TAMPER SWITCH BY OTHERS MONITORED BY NMM-100PI lt It 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORESNOTIFIER THAN ONE FLOOR SHALL BE RISER RATED. ® ADDRESSABLE INPUT MODULE - MINI NNM NOTIFIER SINGLE GANG ALIGN WITH OTHER EQUIPMENT 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. Et 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND ® ADDRESSABLE OUTPUT MODULE NC NOTIFIER 4" SQUAREE X 2.125" DEEP BACK ALIGN WITH OTHER EQUIPMENT ♦ LIGHTNING PROTECTION DEVICES. V 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL. BE MECHANICALLY Q PROTECTED. EF ADDRESSABLE MANUAL PULL STATION DOUBLE GANG BACK BOX NOTIFIERIOR 46" TO CENTER AFF NOT-BG12LX 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED ASJ >111 'FIRE ALARM CIRCUIT". m 'I"'1 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE NOTIFIER (NFPA 72). Z� PHOTOELECTRIC SMOKE DETECTOR NP-100 4" OCT OR SINGLE GANG CEILING MOUNT 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION I OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). NOTIFIER FIXED TEMPERATURE HEAT DETECTOR 4" OCT OR SINGLE GANG CEILING MOUNT i 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR NH-100 AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH III SECTION 14.6.2.4 (NFPA 72). *****WP - WEATHERPROOF DEVICE _ If - LOW FREQUENCY DEVICE C - CEILING MOUNT Z v 1 W 4. O I V co SITE r Cl) W >40, • W F- ¢�` 0 A Z DC V) no m tidy?'' �! rU�+ r•+1......1 CO Lb ,.� A "' 0 J wio Ca 6;V J Cao) 4c o zc < " y p ti���Gs full r IIIIIII i U I W "4' lil lil BATTERY CALCULATIONS o a (� tY NOTIFIER NFW2-100 (I ) F I~ U_ • REVIEWED/APPROVED: PART # DESCRIPTION QTY STANDBY ST4NDBY TOTAL ALARM ALARM TOTAL NFW2-100 MAIN CIRCUIT BOARD 1 0.1450 0.1450 0.2750 0.2750 N-ANN-80 REMOTE ANNUNCIATOR 1 0.0150 0.0150 0.0400 0.0400 '' .....' .'- i).--1 NOT-BG12LX PULL STATION ADDR 1 0.0004 0.0004 0.0005 0.0005 BEN BREIT-4460LEA DWG REV./DATE NP-100 PHOTOELECT ADDR HEAD 5 0.0003 0.0015 0.0065 0.0325 0 07/10/17 NH-100 HEAT DETECTOR HEAD 2 0.0003 0.0006 0.0065 0.0130 NMM-100P MINI MONITOR MODULE 4 0.0004 0.0016 0.0050 0.0200 NC-100R RELAY MODULE 4 0.0003 0.0012 0.0065 0.0260 NOTIFICATION CIRCUIT SCHEDULE STANDBY TOTAL 0.1653 ALARM TOTAL 0.4070 DRAWN BY: - VO LTAG E DROP CALCULATIONS *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* TME AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DERATE CHECKED BY: STANDBY 0.1653 X 24 = 3.9672 - BJB NO CHANGES ALARM 0.4070 X 0.0833 = 0.0339 - FILE NAME: TOTAL AH = 4.0011 4.8013 FA.dwg DRAWING#: BATTERIES TO BE INSTALLED: 7.0 AH FA-1 ORIG.SHEET SIZE:11"x 1T #OF DWGS IN SET: SHEET 1 OF 5 888 FIRE ALARM RISER DIAGRAM FIRE ALARM OPERATIONAL MATRIX oE4 ?,OfD SYSTEM OUTPUTS 16e. o 133 L' SLC TO FACP � ,,�����•1 filth EOL"e7kI1 �O? �< � ���P� JB� Imo/ ® EOL"e 7kn 18/2C FPLR • CQ`P" �C�P 63 �0�+ y �0�' • ��+vs ��a�' cv BY OTHERS p 4.O & 4P 43 op * .v-- r al a •, C 4 � ,Eye ,0-4 .,,� _t4c g c'a- 6 �4 0P & P a0 0 sem % P P J 0�'eta FACP (TYPICAL) c``'. P� �4 y ycS�A PJ y``'A-° .�yJ � �P ` t. 4% Q P Q k. S. y. Qc. �. J O Ck CSS 1 111 �* 0�0� �P �P �P P y y aP P� c c�' , ELEC SYSTEM INPUTS P`.-P`'P- - 4- of Q Po,PGS Is, eF� ,Q<'GQ�'pPP� , `3�`a Q�" NOTES: £ SLC PULL STATION • • • • • • SLC TO FACP___9- • • • • • • 18/2C FPLR I NOTIFIER 1 SPARE SMOKE DETECTOR - NON ELEVATOR NFW2-100 2 SPARE SPRINKLER FLOW SWITCH • • RJ FACP 3 SPARE SPRINKLER TAMPER SWITCH • • W/INTEGRAL RJ DACT Ce 1 4 SPARE LOSS OF AC POWER AT FACP • • CAD TO FAA OPEN CIRCUIT • • �/ 120VAC DEDICATED TYPICAL NACDISCONNECTION OF BATTERIES • •• 18/40 14/2C FPLR GROUND FAULT • • REMOTE ANNUNCIATOR (TYPICAL) SMOKE DET. - ELEVATOR LOBBY MAIN FLOOR • , • � SMOKE DET. - ELEVATOR LOBBY OTHER FLOORS • • • • • • • • ce -SMOKE DET. - ELEV MACH RM/TOP OF SHAFT • • • • • • • • • HEAT DET. - ELEV MACH RM/PIT/TOP OF SHAFT • • • • • • • • • LU NOTIFIER SHUNT VOLTAGE MONITOR , • • r N-ANN-80Z TO/FROM FACP L FAA • PRESS SIGNAL SILENCE KEY • • � ♦♦♦♦ r� PRESS RESET KEY • V V J (i) CO2 VW ELEVATOR CONTROLS (TYPICAL) LU Z mum Lr U) ELEVATOR EQUIPMENT CLOSET (RM ) V COI J / '� TOP OF SHAFT DETECTOR SCHEDULE MODULE SCHEDULE J (�2 1 cl RECALL TO MAIN `-P TO I ADDRESS DEVICE LOCATION / AREA ADDRESS DEVICE LOCATION / AREA �y'� W OTHER LOBBIES I RECALL TO ALT ELEVCONIART D-1 PHOTO AT FACP ELEC M-1 SPARE SPARE �++OLS Q n/ P + HAT FLASH GUAR D-2 SPARE SPARE M-2 MONITOR AT FACP TROUBLE COMMUNICATOR cn IJP MAIN LOBBY E I I SHUNT TRIP CABINET 0-3 SPARE SPARE M-3 FLOW WATER FLOW J m D-4 SPARE SPARE M-4 TAMPER TAMPER SWITCH SHUNT VOLTAGE PAM SHUNT TRIP J D-5 SPARE SPARE M-5 PULL MANUAL PULL 0 Z Q SLC TO FACP . JB © ©- O D-6 PHOTO SMOKE AT FIRST FLOOR ELEV M-6 SPARE SPARE O D-7 PHOTO SMOKE AT ELEV CONTROLS M-7 SPARE SPARE _ (0 0 W ELEVATOR PITI 18/2C FPLR I I D-8 HEAT HEAT DETECTOR AT ELEV CONTROLS M-8 SPARE SPARE 0 IS Q Ce D-9 SPARE SPARE M-9 RELAY RECALL MAIN AT ELEV CONTROLS .12 * INSTALLED IF NEEDED D-10 SPARE SPARE M-10 RELAY RECALL ALT AT ELEV CONTROLS coV/ ~ D-11 SPARE SPARE M-11 RELAY HAT FLASH AT ELEV CONTROLS DWG REV./DATE D-12 SPARE SPARE M-12 RELAY SHUNT TRIP AT ELEV CONTROLS 0 07/10/17 D-13 SPARE SPARE M-13 MONITOR SHUNT VOLT AT ELEV CONTROLS D-14 PHOTO SMOKE AT SECOND FLOOR ELEV M-14 SPARE SPARE D-15 PHOTO SMOKE AT T.O. ELEV SHAFT M-15 SPARE SPARE DRAWN BY: 0-16 HEAT HEAT AT T.O. ELEV SHAFT M-16 SPARE SPARE TME D-17 SPARE SPARE M-17 SPARE SPARE CHECKED BY: D-18 SPARE SPARE M-18 SPARE SPARE BJB D-19 SPARE SPARE M-19 SPARE SPARE FILE NAME: D-20 SPARE SPARE M-20 SPARE SPARE FA.dwg ***SPARE CONTINUES*** ***SPARE CONTINUES*** DRAWING#: D-99 I SPARE ISPARE M-99 SPARE ISPARE FA-2 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 2 OF 5 888 aawa O m Agh (O 4-lel V W Y. FA-3 i -_-Illr , % / SII///'/'//. % % ' �'� ;;,,A$7-: I�/'/ ® !�/�,/ i✓- (01;4•rpr 1111111 8 r �/ /, /�/ ."Io 449.:/ Ployfire4,131/117/17/atr/4" � rii/ r /� %//. iia.•/ ` IWy�jz le �� % i.'./� // // %%% 01 <� Ffes �-�rif� - g Ror% .fikft �/ //// fill/ii/i�iia4'i i/.�iiiiii %y' P ;3/10%////, ,✓AP/ I--------4Ier E-it I re//ilii%`tx j v., A j �i ,/ r//////////7,14 %�.., , : i4 _ I, ai. . 97 7/ r z' r - % , 5 SECOND FLOOR 4 / /� FA-3 I/ % /�/////.---- . -- 1117 NOT TO SCALE ce 4 \ \\�\\ FIRST FLOOR FA-3 NOT TO SCALE D J II: m I I re I W I— r Z ,_ t, '`` *AT T.O. ELEVATOR SHAFT C.) V J WF M-3 E 44D-15 TS M-4 Sit (4D-16 W LU 1 J D-1 0 I Z (n (4 I to c9 D-14 m W 2 - ----T I --ie..�rrlir"r n,7.rtiawu i�- t -727_77 i( I N iI m N , 1 FIRST FLOOR ELEC � ; I � ��, , a � : ,_._ -- - __ -_ _ --- - _ __- _ _ � O zo 0ELEVATOR CONTROLS SECOND FLOOR ELEV = N o w SCALE: 1/8"=1'-0" D-� Q 1 D-8 SCALE: 1/8"=1 -0 COr 0 RECALL MAIN O4 M-9 V♦ - - RECALL ALT ®M-10 DWGREV.1 DATE 07/10/17 D-6 HAT FLASH €4,M-11 `''P SHUNT TRIP M-12 1E3 0 M-5 SHUNT VOLT ®M-13 ----- . ._. ._1 -._ _.......v.. __:.�._.. ---.-',+ . _..___. ....._._._.. DRAWN BY: TME CHECKED BY: 1 BJB FILE NAME: FA.dwg DRAWING#: it CFIRST FLOOR ELEV 0 4' 8' 16' FA-3 SCALE: 1/8"=1'-0�� ORIG.SHEE7SIZE:11"x 17" #OF DWGS IN SET: SHEET 3 OF 5 o.o *6.Wo >OfO _1 NOTIFIER N-ANN-80 ANNUNCIATOR m 0 o SLC - 1 / amLuu v SLC - TO NEXT DEVICE 5 / FROM FACP SLC IN SLC OUT OR !�No • ""'' \ OR PREVIOUS DEVICE SLC +terzc) SLC�+L 1 C) TO FACP FOR \ OPTIONAL CLASS A g Y r 15 CAUTION: DO NOT LOOP WIRE UNDER TERMINAL. 1.1 ___ BREAK WIRE RUN TO PROVIDE / n-1, FROM FACP ,--- TO NEXT DEVICE CAUTION: ! OR = OR SUPERVISION OF CONNECTIONS. • • DO NOT LOOP WIRE UNDER PREVIOUS DEVICE O r� TO FACP FOR • TERMINAL 1 OR 2. F_` \/��` OPTIONAL CLASS A BREAK WIRE RUN TO PROVIDE SLC - I/ ♦ I L+_ V '� - co y SUPERVISION OF CONNECTIONS. O ' SLC IN �I�\ - SLC M > O % m m 14 111.111 �,q �� SLC OUT � � (TYPICAL 18nC) 7/� Z Z > 0 it sialli i (TYPICAL talc) SLC + 1. :'ice \ a a N Z SLC + 0 1 2 3 4 g .Li1 ; m < *� STRIP CAU�y G r'• n ® 8 sL J.L ATO �� • • ? • t 0 �- l / ANNBUS B J ANN-BUS (B) ,I1.- � Ce __ _ _ FROM FACP OR CAUTION: PREVIOUS DEVICE (TYPICAL 18/2C) (TYPICAL18/2C) TO NEM DEVICE DO NOT LOOP WIRE UNDER ® ANN-BUS (A) J ` ANN-BUS (A 0 TERMINAL 1 OR 2. 'LJ1.J Q BREAK WIRE RUN TO PROVIDE O O O SUPERVISION OF CONNECTIONS. BASE-B210LP (+) 24 VDC / v (4-) , + 24 VDC PHOTO SMOKE DETECTOR FROM FACP OR (TYPICAL lent) (TYPICAL tent) TO NEXT DEVICE � I , HEAT DETECTOR UL LISTED POWER SUPPLY \� l N .:: (-) GND / ` (-) GND Ce 6' PULL STATION W SMOKE/HEAT BASE REMOTE ANNUNCIATOR PULL STATION F— Co Z illo SCALE: NTS Ell SCALE: NTS SCALE: NTS W V to 2 FROM FACP OR CO PREVIOUS DEVICE W SLC - N. / SLC - LIJ TO NEXT DEVICE Cl) SLC IN SLC OUT OR Z /(TYPICAL tanC) (TYPICAL 18nC) TO FACP FOR ♦ IY SLC + SLC + OPTIONAL CLASS A • V♦ 0 �/'� er \ SLC - SLC - TO NEXT DEVICE V/ FROM FACP SLC IN SLC OUT OR n d (31 ( u � OR TO FACP FOR COm (TYPICAL tent) (TYPICAL tent) OPTIONAL CLASS A W I �\` PREVIOUS DEVICE SLC + • SLC + Q O` I I J - � MONITOR MODULE CO M imm J `~ Q 11 TorIII I 6 7 8`SLC - 4 Ti TIO •1-RLY 2, C A. 10 SSSS 5B�A 0 2 O SLC + ;r'�"I T2. TS 31,RLY 2, NC 3 ��13 3\-'�} „ed I I Ts T� y���RLY 2, NO 2 �4 � 2 � �/ � 10 5 10 I-1— UNUSED .L UNUSED OkTI. T7 �-`'RLY 1, C TENS LOOP ONES• •S . COV♦ O RLY 1, NO I T5 ? 1'6 (RLY 1\ NC (-) (+) (+) (_` DWG REV./DATE CAUTION: r / J DO NOT LOOP WIRE UNDER I,1` �i J YELLOW VIOLET RED BLACK TERMINALTIRUNOR T C"-=`_))( ' In 11111 � \�/\ \ / 0 07/10/17 BREAK WIRE TO PROVIDE (J I SUPERVISION OF CONNECTIONS. [ ((..„,..7- .."----. �� TYPICAL 18/2C 1IrlJ�) \ TO DRY CONTACT DRAWN BY: INPUT DEVICES TME RELAY MODULE CHECKED BY: NORMALLY OPEN BJB (TYPICAL 1812C) FILE NAME: TO CONTROLLED FA.dwg DEVICEIUNIT DRAWING ft: CORELAY MODULE (SECURITY PANEL) MONITOR MODULE SCALE: NTS SCALE: NTS FA-4 ORIG.SHEET SIZE:11"x 17" A OF DWGS IN SET: SHEET 4 OF 5 08a #W O O a'N O 1D TO NEXT DEVICE w w S TO NEXT DEVICE OR 5 OR TO FACP FOR TO FACP FOR OPTIONAL CLASS A V 8 OPTIONAL CLASS A • g w SLC - SLC - SLC - • SLC - FROMMRFACP SLC IN SLC OUT FROM ORACP SLC IN SLC OUT PREVIOUS DEVICE SLC +1e/2C) (TYPISLC�tL 1 ) PREVIOUS DEVICE (TYPICAL 18/2C( (TYPICAL 18rzq • 111%6 SLC + • SLC + %a MONITOR MODULElik MONITOR MODULE 8 67� nn 6�� bs4i ) � ADDRESS 56'�� 3 1.) ADDRESS 34i0) '� frit 44 2101 2 g lt 3 3 , 0 �2''0 2 0 TENS LOOP ONES 0 0 TENS LOOP ONES • • mow • • • • • • (—) (+) (+) (—) (-) (+) (+0 (-) YELLOW VIOLET RED BLACK YELLOW VIOLET RED ` BLACK \ / 1 ` J \ TYPICAL 18/2c J ` Ce \ TYPICAL 1812C N.,PADDLE FLOW SWITCH \ TYPICAL 18/2C 1 Q OR J TAMPER SWITCH TYPICAL 18/2C PAM-2 CCI NC NCS WHITEC BLS 1 I ( •OV(-) i • C C11.___1 J L ICe Re k II GREY •+24V@0.015 A NC •- YELLOW NO NO! 1 RED •+12V g0.015A NO • ORANGE • I— ***FOR USE WITH FLOW SWITCH*** JEOL e O W '^ POWER SOURCE /v♦ V J (BY OTHERS) e 120VAC 120VAC POWER FLOW BELL TYPICAL 18/20 p OUT (BY OTHERS) W I- 0,10 >,— W.4410 - \ PWR(IN) PWR(OUT) 0 0 0 0 0 0 0 0 0 S 0 O 0 0 0 0 0 0 0 0 s s 0 Z CD SAFE OFF y -a y A 'O v -D D A Nw i O A + A n 6 N ♦/� (� ��/� -��, UNUSED = Z tO 44 X N x 1 0 �/ CONDUCTORS C) -1 J N W P + Z Z m PWR(IN) O O PWR(OUT) v v v DSC-3G4010CF DSC-3G4010CF POWER SUPPLY m W1 PGM4 IS OPTIONAL BECAUSE TERMINAL BLOCKS Q WI1/ DIAL TONE IS NOT GENERATED WHEN CELL L J SIGNAL IS LOST J CO Cr) COMM TROUBLE MONITOR J m ° FLOW OR TAMPER SWITCH MONITOR 0 2 o Q © SCALE: NTS © SCALE: NTS _ o W (,) 53 - CO Fp LL DWG REV.I DATE 0 07/10/17 DRAWN BY: TME CHECKED BY: BJB FILE NAME: FA.dwg DRAWING#: FA-5 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 5 OF 5