Loading...
Report (34) Bend Office (541)330-9155 Geotechnical Office (503)601-8250 Carlson Testing, Inc. Eugene Office (541)345-0289 Salem Office (503)589-1252 Tigard Office (503)684-3460 April 20,2016 11606180 Permit No: N/A P.O.No: FIELD INSPECTION REPORT DATES COVERED: April 19,2016 PROJECT: Harris—GB—001—Load Testing ADDRESS: 11960 SW 122"d Ct Tigard OR INSPECTOR: K.Wallis—ACI#01295086,OBOA#1101 04/19/16—Proof Load Test A CTI representative arrived on site as requested by David with Lamont Bros Construction to proof load test (4) hold down anchors in the front of the garage of the house.The anchors were%Z"all thread,(2)on each side of the garage door.CTI spoke with David and was given permission to cut out the blocking and dry wall in the (2) areas in order to test. The anchors are numbers#1 is the southernmost anchor,#4 is the northernmost anchor. #1 anchor failed at 3180 lbs. #2 anchor held the specified load of 4837 lb.for 1 minute #3 anchor held the specified load of 4837 lb.for 1 minute #4 anchor held the specified load of 4837 lb.for 1 minute 4837 lbs.was specified by the engineer design professional for the job. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full,without prior authorization from this office. Under all circumstances,the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared.No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter,please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING,INC. im Suess Project Manager KW/sc cc: Gabe Harris Gabe.jharris@gmail.com Lamont Bros LLC—David Patrick david@lamontbros.com Lamont Bros LLC—Joseph.Patrick Joseph@lamontbros.com West Coast Engineering(WCE)—Sean Ramstead seanwce@gmai1.com City of Tigard Building Division—Walter"Chip"Barnett Final LTR only I NCL only 8430 SW Hunziker St..Tigard,OR 97223 PO Box 230997,Tigard,OR 97281 04-19-16 fr 610(kw) Bend Office (541) 330-9155 Geotechnical Office (503) 601-8250 Carlson TestiEugene Office (541) 345-0289 ng, Inc. Salem Office (503) 589-1252 Tigard Office (503) 684-3460 Daily Report of Proprietary Anchors Client: LAMONT BROS LLC - DAVID PATRICK Project: HARRIS-GB-001 - LOAD TESTING CTI Job#• T1606180. Address: 11960 SW 122ND CT TIGARD OR Jurisdiction: TIGARD CTI representative J. PILAND OBOA 282 was on site this date Apr. 27, 2 016 to perform Special Inspection for: Permit MST2015-00235 DFS #(s) PO Number: SCOPE OF INSPECTION Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. Name: DAVID A CTI REPRESENTATIVE WAS PRESENT FOR (1) EPDXY Company: LAMONT BROS LLC INSTALLATION. p y SOUTH ANCHOR WAS JACKED BY A CTI 2. Inspection was "IBC" x Continuous Periodic REPRESENTATIVE TODAY, AND REDRILLED TO A DEPTH OF 8" INTO FOUNDATION STEM WALL. EPDXY PLACED: PROPRIETARY ANCHORS (1) 5/8" DIAMETER X 18" LONG X 8" EMBED PER YesNoN/A DESIGN AND ICC REQUIREMENTS. 1. Reviewed previous inspection reports? x 2. Reviewed evaluation report? x Verified following items meet manufacturer's published installation instructions. REPORT SUMMARY 3. Verified minimum embedment depth of the anchors. X 1. Work inspected was: I X I Completed In progress 4.Verified installation of the anchors. X 2. Completed work inspected was in compliance with 5. Verified anchor diameter. X I x I Approved plans and specifications I I Shop drawings 6. Verified steel grade. X I I RFI Design change Submittal N/A 7. Verified hole diameter. x 8. Verified type of drill bit used. X Document #(s) A/S 1.1 Dated: 01/04/16 9. Verified hole cleaning method. X 3. Noncompliance item(s) were noted this date, details on 10. Verified adhesive application. X following page(s). Yes No x N/A 11. Verified edge distance. X 12. Verified spacing. X 4. Noncompliance item(s) were reinspected this date, details on following page(s). I I Yes No x N/A 13. Verified installation torque. Conform Remain in progress Evaluation report number & date: ESR-2508 (07/2015) Report(s) findings were discussed and left with LANCE of OMEGA CONCRETE INC Name of product being installed SIMPSON XP Batch Number 245T472T Expiration Date 12/02/16 Based on the Code, approval is required from the Building Official before the SPECIAL INSPEC TED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). I I Distribute attachments. Page 1 of 2