Plans (108) APEX SYSTEMSM ®
RECE
iJ E Architecture x interiors
Planning•Engineering
TENANT IMPROVEMENT AUG 8 2017
PeamLat
1-14°O°4•°°,'-F"-••°./1? • �Ro 2 LINCOLN CITY OF TIGARD vanmaraWA
�fp �- e� , 10220 SW GREENBURG RD BUILDINGDIVISION
� p ° " 7 TIGARD, OREGON �°�
(11;;,/,&"11 , MACKENZIE.
Cita
! ''! '` $ ,/ INDEX OF DRAWINGS DEFERRED SUBMITTAL
( 2074 MC SECTION 707,3,4.7 (VA*Wats perm 3) •••
.,,,,-0 N,sI. mot TIME SHEET.917E PLAIN!O4'PLAN CODE P3344 Y.LEGEND AND NOTES 3780 ALARM PA .x. w
'f 19 i7Q k cl A7.10 0PAI0LITION PLN,PARTIAL FOURTH FLOOR PLAN NIO.NOTES FIRE ALARM
l �'� k M.20ELEV.20 RCP,REFLECTED CEILING PLAAND NOTES MECHANICAL
{`W U,y` A4,10 ELEVATION,DETAILS AND SCHEMES
ELECTRICAL
.«.jJ�w I 4 ? 43.10 DETAILS CHITPLUMBING
SCOPE OF WORK EXIT ILLUMINATION
PrataatAREA OF WORN THE SCOPE OF WOIO FOR TRE PROECT INCLINES INTERIOR TENANT IMPROVEMENTS NOTE:DESIGN BUSUERS FOR M.E.P.AND FP.ARE FULLY RESPONSIBLE FOR THE DOM APEX SYSTEMS
..\.. it Fx.Ixu81.4c., FOR AN APPROA2MATELY 4,704 SQUARE MDT TENANT ON THE FOURTH Cr SIX FLOORS. OF THESE S431EM 441'.T CNENTS THESE SYSTEMS/COMPONENTS RE ENiS 5110WWN ON DOCUME4T9 8�E 450
Y �'"� -iQ WOW TO INCLUDE DEMOLITION NEIN WALLA DOORS AND.aE1.irE6 AND NEW CABINETRY. ARE SCNEMAnc ONLY.THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPUANr IMPROVEMENT
IIDESIGN,PROVIDE DESIGN DOCUMENT SUBMITTAL M ARCHITECT OF RECORD FOR REVIEWTENANT
TENANT APPROVAL' PRIOR TO RAOM TrAL
21
14
'�T — 20 FAY TURA mom
ioi SITE PLAN DESIGN/CODE DATA LEGEND
NTSGOWILA COM 8014 MSC =¢ EXISTING CONSTRUCTION TO BE DEMAISHEO ,4q .I)
CONSTRUCTION TWO MPE 1-8 Il' .,,�'j'
TENANT AREA(APPROH: APPROI.4.104.AF. maxamamma NEW WALL TO UNDERSIDE OF GRID,SEE 2/A5.20 E
OCCUPANCY LOAD: 41 EwwwwFwam EXISTWO 2 HOUR RATED WALL TO REMAIN ;400 400 °,tried�
EXISTING i NOIR RATED WALL TO REMAIN % .I
2 REWIRED DOTS 2 EXITS PROVIDED masmamma EXISTI O DEMAND WALL TO REMAIN
ALL EXITS ARE EXISTING AND NAVE APPROPRIATE EX110 DETECTION NEW OE 15014 WALL,SEE 3/48.20 V.4.
BUILDING IS NLLY SPRIER=AND HAS NEPA SMOKE DETECTION (�[F 1 iY
Wim ON SITE
EEMERGENCY OENDIATOR FOR FIRE LIE/SMETY BACKUP POKER W EXISTING OUTLET
� VALUATION • E%ISnNO QUADRUPLET(OUTLET
ENSTINO COVERPLATE ® xiVam`i i WTI
/� ‘11111P11.11111111111 hibk VALUATION OF PORK. 958.000 NEM OUTLET AND VOICE/DATA ROUGH 1N LOCATION y $yp jpRa
�� �� ® NEW BASE FEED,(1)CIRCUIT PER(4)'WORKSTATIONS wixwr PRIOR Wnrtx•ouMRa
GENERAL NOTES a NEW BASE VEIL(DCIRCUITS REVI90NS
1
111 lit
�. NEW FLUSH FLOTED CUTLET B8 ^galINF
ill A. THE DRAWINGS LOCATE PRODUCTS.SURFACES.AND MATERIALS AND THE NOTES CWMY B NEW FLUSH FI,OOp ELECTRICAL AND DATA ROUGH IN LOCATION
Wh
INTENT.THE PRO.ECT INTENT IS TO PROVIDE FORA COMPLETE WORKINGSYSTDA 4..T
a DESIGN NEW DEDICATED*MERMEN
B. ALL ED
MIHSHN ANO OM OLS SHALL CONFORM r0 TILE IAL MEANING BUILDING
_ COTE AUTHORITIES
AND f0 COMMONS ANO SPECIFICATIONS OF ALL OOElU1NG PD EXISTING THERMOSTAT
. �' AUmORTEA I
C. SUM DISCREPANCIES SHAU-BE All0. CONTRACTOR ANO SLNBCONTRACi0R9��CAREYULLY INAMII6 TIAL 971[M'0NO ADOMONAL COST tO THE 1HELARDSors. SHEET TITLE
E REFER TO ENLARGED PLIAS MO ELEVATIONS WHERE DNOCATED FOR ADDITIONAL SKEET INFORMATION ENN.VROED PLANS TAKE iRECEOENCE OYER PlAN3 or
STALER SCALE, EKE REWIRED ENT
x"J{ d�>,(u _1 I ANDD 1 000 OPT PRECEDENCE OVER PLANA/N THE CAS!OF A CWfI,ICi,THE
TITLE FEET,SITE
A�1' F. �TREPOREN I N14111 SHOULD BE
TO AU.1135044000 WHERE THE SAME �1, ALIGN FACE OF FINISH MTH FACE OF FINISH PLAN.KEY PLAN,
f ,4 AREA OF LANOLOPD CONDITIONS OCCUR UNLESS NOTED OTHERWISE CODE SUMMARY,
IYOROVFAIENTS 0. THE TERMS'MOW f111191 FLOOR'(AFT)AND•P0119N ROOK ELEVATION"(FEE)REFER ill- EXISTING GELLING OTR LEGEND AND
TTOOI�L
AA B TU EEVATI HETH
,oilmen BUNAAA B.comeos TE DECK,OR NCRIE
AREA OF N. 001307 SCALE ORAMINOS. Aa.:, EXISTING SWPLY/RETURN MIT TO REMAIN
WORt I. CUTTING AND DRILLING OF STRUCTURAL MEMBERS NOT DETAILED REQUIRES THE WRITTEN ('_.
t ti PENNISSIOI OF THEE4
STRUCTURAL 001EER OF RECORD, F D01040 Cm'UDNT FIXTURE TO REMAIN
d SANE AND ACME'DEMOLITION DEBRIS AS APPUCABRE.ALL DEMOLISHED OR REMOVED
1111 EXISTING MATERIAL SHALL 8E LEGALLY DISPOSED.COORDINATE 1Wm CITY OF LANE ® NEW OR RELOCATED FarLICHT FIXTURE DRAWN 811 SYS.CM
• 05100 REQUIREMENTS FOR RECTELNO/RE-USE OF DEMOLITION DEBRIS TI EXISTING SMCNE DETECTOR MIMEO BD SBH.POk
N. THE.CONTRACTOR TS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THEIR WORK.TIE
—_— •__ ; ___. _ ._..._.•' CONTRACTOR WILL COORDINATE CLEAN UP 34 ALL AREAS ED BY WIT OR ANY
LONGEST COMMON PAT WR
MATERIALS BOTH DUPING CCWSTRUCTRX4 AND UPON COMPLETIONLETIONOF TE PROJECT. W EXISTING SPEAKER SLEET.
OF TRAVEL•SC-S• OF THE FOR INCLUDING�BY°TENAIf ALL WINDOWS AS NECESSARY 50 THAT THE SPACE 6 READY 27 NEW AMMO
COS EXIT SON G0.01
D AOWAL.35'-9' L ALL DEMON-BUND ITEMS.SYSTEMS Atm ELEMENTS ME TO BE SUBMITTED FOR REVIEW X NEW ENT SON
AND APPROVED Cr MOTTO IE
M.EXISTING MATERIAL NOTED TO BC RETURNED TO THE OWNER SHALL BE SAFELY STORED
toNLV PLAN PLAN AND PROJECTED UNTO.1T IS ROOM MOM THE ME BY THE OWNER.CONTRACTOR
NTS SHALL COORDINATE NIT TEE OWNER.
TRUE PLAN
NoaT NOR
THp JOE 21.14
.E17,iry rGET:,,0 aV,S.iM v,-aa.pw w„BMs xr'4
RECEIVED
II - City of Tigard AUG8 Permit No.: /` 50
I13125 SW Hall Blvd.,Tigard,OR 97223 G 2017 %�� /c-�'C�/��
Phone: 503.718.2439 Fax: 503.598.196Q.y Date Received: (
Inspection Line: 503.639.4175 "�I ' Ut I I
TIGARD Internet: www.tigard-or.gov 3UILDING f v` t n�Q1VBy � I/0 '')1���� �
FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONS
OR TENANT IMPROVEMENTS
(1 to 10 SPRINKLER HEADS WITHOUT PLANS)
Project Name: {'s,-;cmc, Occupancy: &tom t
Job Address: t o 2.,7,0 ,4.0 C Z Zb3 J7--cot Type of Construction:
Suite: 4-`'.;0
Contractor: VA-c tj L tip Phone: 3 1 i O ( 1--
Number of Proposed or Altered Heads: 4-i
Type: -t' Hazard: L-1 t-31` Density: a ` Q
I, k&, tAPT- 2-+4+- Oregon Construction Contractors Board No. ) `4'U
certify the following is true and reasonably defines the scope of work for this project:
a) All work is limited to drops and armovers in a light-hazard occupancy.
b) Positions of sprinkler heads relative to architectural features such as soffits, beams,partitions,walls, etc.
complies with current adopted edition of NFPA 13.
c) The proposed work does not require hydraulic calculations.
d) Only one sprinkler head will be installed from one drop (exception: up to two heads from one drop may be
installed when each head is in a separate fire area).
e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13.
f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13,
Section 8.3.3.1 for exceptions).
g) The installation shall comply with the requirements of the current adopted edition of NPFA 13.
h) Piping shall not be concealed until hangers and bracing are inspected.
i) Final approval shall be subject to onsite tests and inspections.
In addition, I understand the following is required:
• Submit(3)copies of a sketch showing the area of work within the building's structure.
• Building fire protection system permit.
• A copy of this document with a copy of the sketch attached shall be available for all inspections.
Signature: `'� 4\1M'`" Date: S-`7 t 1
Print Name: l K,40,__ __
r ,
I:\Building\Forms\FireSprinklerAffidavit_071514.docx
Page 1 of 1